SDCCH Listare alarme State TRX TIMESLOT rxmfp:mo=rxotg-1988,subord,faulty; check all faults from TG ; they will indicate the same thing (Degraded or Lost Communication to Radio Unit ) rxmsp:mo=rxotg-1988,subord; rxasp:mo=rxotg-1988; display the status of the TG and subordonqte MOs alarm status Basic steps : 1) find the TG corresponding to the cell: rxtcp:moty=rxotg,cell=Cell; 2) display the status of the TG and subordonate MOs. rxmsp:mo=rxotg-TG,subord; If the TG/TRXs are manualy blocked, then lock the corresponding cells with the command RLSLC :cell=CELL,state=halted ; (of course the cell alarms are automatically cleared) . If the TG and subordonate MOs are unlocked go to step 3; 3) Are all TS up (OPER and ENA) and everything in use when givving the command RXCDP? If no, check with RXASP; and RXMFP; the Faults from the site take the appropiate action. In this case, sometimes helps if you reload the TG: rxbli:mo=rxotg-TG,subord,force; rxese:mo=rxotg-TG,subord; rxesi:mo=rxotg-TG,subord; rxble:mo=rxotg-TG,subord; rlslp:cell=C13879C; CELL SUPERVISION OF LOGICAL CHANNEL AVAILABILITY DATA CELL C13879C SCTYPE ACTIVE YES CHTYPE BCCH SDCCH TCH TCH TCH TCH TCH TCH CBCH CHRATE SPV FR FR FR FR HR HR 1 2 3 5 1 3 LVA 1 24 20 20 20 20 0 0 0 ACL A1 A2 A2 A2 A2 A2 A3 A3 A3 NCH 1 16 21 21 21 21 42 42 0 END Is not ok to have NCH < LVA… LVA should always be less than NCH. This is the cause for SDCCH alarm in this case. That parameter (LVA for SDCCH) should be changed for C13879C . CONSISTENCY CHECK 2G to 3G reselection HOPPING SDCCH CNAI 2G E/// integration BOGEDO