Procedure upgrade TRX Ericsson 1. Tools and Other • • 2. Preparation • 3. Winfiol CDD as per Customers request. Read and understood General Requirement before halting Customer Lives SitesCDD as per Customers request. Step2 Upgrade • Find TG value using cell name: • • • Check in BSC whether recording is ongoing or not. Halt the CELL • • Create/modify MCTR & TRX definition as per the RRU type and TRX mapping Create New TG and subordinate Mo • • RXBLI:MO=RXOTG-1,SUBORD,FORCE; Confirm the RU type • • RLSTC:CELL=CELL1,STATE=HALTED; Block the TG • • rxtcp:moty=rxotg,cell=CELL1; Use Rsite name as same as Existing TG Rsite name. Change the Software as per Request if necessary. • • RXMOC:MO=RXOTG-1,SWVER= B1316R087D; De Block the TG 3. Step2 Upgrade (continue…) • Frequency, Maio, HSN to be change as per CDR if requested • • LVA Setting to be done without fail • • • RLSLC:CELL= CELL1,CHTYPE=TCH,CHRATE=FR,SPV=2,ACL=A2,LVA=30; !!LVA= SPV1 (LVA) – 6 RLSLI:CELL= CELL1; Activate or Unlock the site • • Example: • BCCH & BSIC changes: • RLDEC:CELL=CELL1, BSIC=73,BCCHNO=52; RLSTC:CELL=CELL1,STATE=ACTIVE; Check Site status • • TRX status- RXMSP:MO=RXOTG-1,SUBORD; (or) RXCDP:MO=RXOTG-1; Fault code- RXMFP:MO=RXOTG-1,SUBORD,FAULTY;