SIAE link presentation (1)

advertisement
Series 1
12
10
8
B2B SIAE Pilot LINK
6
4
Prepared by : Adel Salah
CAI0680 - CAI0504
2
0
2006 2007 2008 2009 2010 2011 2012 2013 2014 2015
Series 1
Port 1 : Used only for fiber
cable (Traffic)
Port 2 : Used only for Ethernet
cable (Management)
Standard cables and
connectors to be used and to be
isolated properly
FE : Management cable
is connected to T.N to
carry management
traffic .
Management is down
while connecting this
Cable to PC
Customer side :
Management cable is
left beside T.N .
DC Cable connection
SIAE link DC cable to be
connected to Priority load
in power cabinet and to
the appropriate CB rating
Laptop IP must be in
link IP range so ,we
need to know link IPs
Use browser to login by
link IP
user name: system
Password: siaemicr
Acceptance concerns
Acceptance concerns
Fiber ,Ethernet and DC
cables to be routed on
tower and beside cable
tray inside PVC pipes
Acceptance concerns
PVC and flexible
pipes of fiber,
Ethernet and DC
cables arranged
by plastic tie
wraps to be fixed
by steel tie wraps
Acceptance concerns
Double nuts are needed
for link fixation bolts
Acceptance concerns
Only one earth kit stage is
installed for Ethernet
cable
Acceptance concerns
Fiber cables not connected
to T.N
Acceptance concerns
label holder is needed for
fiber and Ethernet cables
Acceptance concerns
SIAE link DC cable is
connected to C.B 10A to be
checked with approval
Acceptance concerns
Standard cables and connectors
to be used and to be isolated
properly
Acceptance concerns
Management is down
while connecting this
Cable to PC
Acceptance concerns
• Fiber ,Ethernet and DC cables to be routed on tower and beside
cable tray inside PVC pipes
• PVC and flexible pipes of fiber, Ethernet and DC cables to be fixed
by steel tie wraps
• Double nuts are needed for link fixation bolts
• Need two earth kit points for Ethernet cable .
• Fiber cables not connected to T.N
• label holder is needed for fiber and Ethernet cables
• SIAE link DC cable is connected to C.B 10A to be checked with
approval
• Standard cables and connectors to be used and to be isolated
properly
• Management is down while connecting this Cable to PC
• Need SOEM mail from BO
• Site BOQs, Design and planning mails to be available before visits