Ifpexol™ IFPEn Integrated Process for Natural Gas Full Treatment Concept • Refrigerated methanol as absorption solvent: - simple, non foaming, non corrosive • 2 independent process steps: - Ifpex-1 for simultaneous water and hydrocarbon dew pointing - Ifpex-2 for acid gas removal • Meets sales gas specifications Ifpex-1, elegantly Simple, simply Elegant • Water and HC dew points down to -90°C (-130 F) • No regeneration system, no heater • Minimized CAPEX, weight and footprint • No gas emissions • Pure water is produced (< 50 ppm residual methanol) • More than 15 references since 1992 (including offshore) with various capacities up to 350 MMSCFD METHANOL MAKE UP COLD PROCESS DRY GAS RAW GAS MeOH / WATER NGL WATER Ifpex-1 Conceptual Scheme Ifpex-2, the Best choice for Acid Gas Reinjection Ifpex-1 Skid at Markham (USA) Capacity 8 MMSCFD Amine Contactor Ifpex-1 Contactor • H2S, CO2 physical absorption to sales gas specifications • Acid gases bulk removal • Controlled HC coabsorption • Mercaptans, COS removal • Mostly pressure letdown desorption • Recovery of dry acid gases under pressure > Best fit for reinjection, EOR applications FLASH GAS COLD SWEET GAS DRY ACID GAS METHANOL / WATER COLD SOUR GAS FROM Ifpex-1 First Ifpex-1 Unit at East Gilby (Canada) Capacity 50 MMSCFD OPTIONAL CHILLER REGENERATION FLASH / THERMAL Ifpex-2 Conceptual Scheme We Process Your Energy Tour Franklin, 100/101 Terrasse Boieldieu - 92042 Paris La Défense - France • Tél.: + 33(0)1 47 67 20 00 - Fax : +33 (0)1 47 67 20 0 7 - www.prosernat.com