® R DIEBOLD 5500 LOBBY CASH DISPENSER L1227 FRONT LOAD - WITH 40mm (1916") CEN I SAFE CALL 1-800-999-3600 444 CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. SAFE PLEASE SEE PLANNING AND SITE PREPARATION GUIDE TP-821762-001. ( DI M ENSI ONS I NI NCHES) CONSUMER ACCESS DIMENSIONS 826 A ( 3212" ) DI M ENSI ONS I N MI LLI M ETRES (1712") TOP OF DISPLAY HEIGHT DEPTH 1360mm 135mm 1 (714") (53 2") B TOP FUNCTION KEY C KEYPAD ("5" KEY) D RECEIPT PRINTER E ActivDispense F HEADPHONE JACK 1257mm 92mm (4912") (358") 1010mm 78mm (391316") (3116") 897mm 0 (35516") 750mm 0 (2912") 37mm 1090mm 463 G 1 THI RD ANGLE PROJECTI ON (18 4") (1716") (43") FINGER PRINT READER 1037mm 28mm (401316") (1 8") 1 918mm H CARD READER 0 1 (36 8") PLAN VIEW HEIGHT - FROM BOTTOM OF SAFE DEPTH - FROM FRONT EDGE OF FASCIA 463 662 (1814") (26116") A 497 1126 SUBJECT TO CHANGE W I THOUT NOTI CE" POWER CORD - LENGTH 2210mm (87") FROM SIDE * OF UNIT TYPICAL ACCESS TO LEVELING LEGS - RANGE 0 - 100mm (31516") (2) EACH SIDE OF SAFE 445 SAFE (1712") FRONT VIEW 33 * FI LE NO.177674 REV.0 444 TO COMPLY WITH CEN I LEVELING LEGS ARE NOT TO BE EXTENDED BELOW SAFE BOTTOM 70 (17916") (1516") 85 448 (338") (1758") 70 (234") (234") 758 SAFE (291316") 826 (3212") SIDE VIEW 1446 ( 561516" ) H 1359 D ( 4438" ) G 1446 C ( 5312" ) F E " ALL DI M ENSI ONS AND DESI GN CRI TERI A (19916") ( 561516" ) PAGE 1 OF 4 B CONDUIT AND JUNCTION BOX POWER REQUIREMENTS REQUIREMENTS THE CASH DISPENSER REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND (CONDUIT GROUND IS NOT ACCEPTABLE). THE CASH DISPENSER WILL PROVIDE A POWER CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS 25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO 1 102mm (4") SQ. X 54mm (218") DP. JUNCTION BOX (ALL BY OWNERS E.C.). DIEBOLD TO SPECIFIED BELOW. PROVIDE FLAT COVER WITH TAMPER SWITCH. CHOOSE AND SUPPLY THE PROPER POWER FOR THE SITE: WHEN "SECUROMATIC" AFTER HOUR DEPOSITORY IS TO BE CONNECTED 2 100-127 VAC (+6%, -10%) AT 50 (±1%) Hz, SINGLE-PHASE TO CASH DISPENSER, OWNERS E.C. TO RUN 19mm 3 (4") METAL CONDUIT FROM 102mm 100-127 VAC (+6%, -10%) AT 60 (±1%) Hz, SINGLE-PHASE 1 (4") SQ. X 54mm (2 8") DP. JUNCTION BOX TO AFTER HOUR DEPOSITORY. 3 OWNERS E.C. TO RUN 19mm 3 (4") 200-240 VAC (±10%) AT 50 (±1%) Hz, SINGLE-PHASE LIQUID TIGHT FLEX METAL CONDUIT OR 19mm 3 (4") 200-240 VAC (±10%) AT 60 (±1%) Hz, SINGLE-PHASE RIGID POWER TO THE CASH DISPENSER MUST BE A DEDICATED SERVICE AND PROTECTED BY A SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT CONDUIT FROM JUNCTION BOX TO CABLE CONNECTING PLATE. 3 19mm ( 4") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 102mm (4") SQ. 4 BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE. X 54mm (218") DP. JUNCTION BOX WITH RECEPTACLE WITHIN 2210mm (87") OF SIDE 100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 15 AMPERES CONNECTING PLATE. BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY (ALL BY OWNERS E.C.) (SEE POWER REQUIREMENTS). 200-240 VAC (~10%) SERVICE, DISCONNECT AT 10 AMPERES THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE 5 ( DI M ENSI ONS I NI NCHES) DI M ENSI ONS I N MI LLI M ETRES OWNERS E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH 2210mm (87") FROM SIDE OF UNIT. SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11. POWER USAGE A A NOTE: MACHINE STATUS WITH BATTERY JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF CONNECTING CHARGING PLATE. (LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT). LOCATE IN AN EASILY ACCESSIBLE AREA. BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION. IDLE (NO TRANSACTION) 60 WATTS 85 WATTS TRANSACTION (DISPENSE IN PROGRESS) 95 WATTS 120 WATTS CONFIGURATION A ALL-IN-ONE PROCESSOR, MOTORIZED CARD READER, RECEIPT PRINTER, AND 4 CASSETTE DISPENSER. THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE CASH DISPENSER, AND THE TYPE OF TRANSACTION THE CASH DISPENSER IS PERFORMING. VALUES ABOVE ARE BASED ON MEASURED AVERAGES FOR THE CONFIGURATION LISTED. HEAT OUTPUT CONFIGURATION 205 BTU/HR IDLE 325 BTU/HR DISPENSING A A WITH BATTERY 290 BTU/HR IDLE 410 BTU/HR DISPENSING CHARGING OPERATING ENVIRONMENT PROJECTI ON *(REQUIRES SOLID STATE DRIVE (SSD) IN ActivCore PROCESSOR. THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN. IF A HARD DISK DRIVE (HDD) DRIVE IS USED, THE MAX OPERATING TEMPERATURE IS REDUCED TO 40°C ( 104°F) RELATIVE HUMIDITY (NON-CONDENSING ) SEPARATION FROM OTHER CABLES BELOW 2 KVA TYPE OF ELECTRICAL RUN FLUORESCENT, NEON OR INCANDESCENT 127mm (5") LIGHTING FIXTURES 2-5 KVA ABOVE 5 KVA 127mm (5") 127mm (5") UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT 127mm (5") 305mm (12") 610mm (24") UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT 64mm (212") 152mm (6") 20 TO 80% AT 32º C (90º F), 20 TO 55% AT 40º C (104º F) WEIGHT OF UNIT 490kg (1080 LBS.) APPROXIMATE. 305mm (12") ACTUAL WEIGHT OF THE TERMINALWILL DEPEND ON THE CONFIGURATION OF THE TERMINAL COMPONENTS AND OPTIONS POWER LINES IN GROUNDED CONDUIT WITH SIGNAL 30mm CABLES IN GROUNDED CONDUIT (1316") 76mm (3") 152mm (6") SIGNAL CABLE INSTALLATION CONSTRAINTS RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE SMALL CONDUCTORS AND LIGHT INSULATION AND WILL NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION. 463 (1814") 35 (138") 79 35 79 (318") (318") 662 (138") (26116") 75 1 89 (312") 2 89 286 (312") 5 TYPICAL ACCESS TO LEVELING LEGS - RANGE 0 - 100mm (31516") (2) EACH SIDE OF SAFE 3 REAR VIEW * 448 TO COMPLY WITH CEN I LEVELING LEGS ARE NOT TO BE EXTENDED BELOW SAFE BOTTOM (1758") 85 70 (338") (234") 70 (234") 758 SAFE (291316") 826 (3212") SIDE VIEW ( 561516" ) 1446 1126 ( 44516" ) * 1 ( 50316" ) 1275 36 4 ( 138" ) AIR VENTS 873 SUBJECT TO CHANGE W I THOUT NOTI CE" 497 (19916") (1114") 4 " ALL DI M ENSI ONS AND DESI GN CRI TERI A ( 3" ) AIR VENTS ( 3438" ) PAGE 2 OF 4 AIR VENTS FI LE NO.177674 REV.0 THI RD ANGLE 0°C TO 50°C (32°F TO 122°F)* SAFE LOCATION SIGNAL CABLE RUN CONSTRAINTS ® R DIEBOLD 5500 LOBBY CASH DISPENSER FRONT LOAD - WITH 40mm (1916") CEN I SAFE CALL 1-800-999-3600 89 89 (312") (312") 20 444 384 463 329 (1518") (1814") (121516") PROJECTI ON 1176 (46516") PLAN VIEW 711 857 (28") (3334") 20 (19916") 1538 HEIGHT OF SPACE IN FRONT OF TERMINAL SHOULD ALLOW A PERSON TO STAND AND SERVICE THE TERMINAL SIDE VIEW (REQUIRED MINIMUM SERVICE AREA ) 1640 (1338") 3 ( 4") ( 64916" ) 497 ( 60916" ) 340 VARI ABLE SUBJECT TO CHANGE W I THOUT NOTI CE" " ALL DI M ENSI ONS AND DESI GN CRI TERI A PAGE 3 OF 4 ( REQUIRED MINIMUM SERVICE AREA ) FI LE NO.177674 REV.0 THI RD ANGLE 1569 689 ( 2718" ) 860 (2") ( 3378" ) MUST ENTER UNIT IN THIS AREA 386 ( 321516" ) ( 28" ) ALL ELECTRICAL AND DATA CABLES ( 15316" ) 837 711 51 REQUIRED MINIMUM SERVICE AREA ( 6" ) (1712") ( 611316" ) 250 (91316") 3 ( ) 4" 622 (2412") 152 20 SHOWN IS THE REQUIRED MINIMUM AREA FOR INSTALLATION AND SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO IMPROVE INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE REQUIRED AREA MAY RESULT IN AN INCREASE IN INSTALLATION AND SERVICE TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR SPECIAL BUILDING CONDITIONS. 304 (111516") 3 ( ) 4" NOTE: ( DI M ENSI ONS I NI NCHES) DI M ENSI ONS I N MI LLI M ETRES REQUIRED MINIMUM SERVICE AREA NOTES: FOR ADDED SECURITY: IT IS RECOMMENDED THAT THE CASH DISPENSER SAFE BE SECURED TO THE FLOOR WITH ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE METHOD FOR YOUR INSTALLATION. ANCHORING THE CASH DISPENSER TO CONCRETE FLOORS: IT IS RECOMMENDED THAT THE CASH DISPENSER BE ANCHORED TO CONCRETE FLOORS 444 SAFE WHENEVER POSSIBLE. DIEBOLD RECOMMENDS USING A M20 OR 19mm 3 (4") ANCHOR BOLT THAT IS 203mm (8") LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 102mm (4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM THICKNESS. ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES. IF THE TERMINAL IS EQUIPPED WITH LEGS, THE LEVELING LEGS MUST BE REMOVED BEFORE THE TERMINAL IS ANCHORED. REFER TO VIEW "A" AND "B" FOR ADDITIONAL DETAILS. 100 244 100 (31516") (958") (31516") 33 ( 1516" ) 518 ( 2038" ) 120 525 ( 2058" ) 758 SAFE CABLE ENTRY OPENING (SEE NOTE) ( 434" ) 1 1 ( 291316" ) ( DI M ENSI ONS I NI NCHES) DI M ENSI ONS I N MI LLI M ETRES (1712") 106 280 ( 11116" ) 232 ( 4316" ) PROJECTI ON 1 222 (834") 404 (151516") 20 20 13 16") 13 ( 16") ( PLAN/SECTION SAFE FLOOR 1-ANCHORING HOLES 2-SNAP-OFF DETECTOR (4) 45mm (134") RECESS DIAMETER (1) 65mm (2916") RECESS DIAMETER 28mm (118") RECESS DEPTH 1569 ( 321516" ) ( 28" ) (2") 688 837 711 SUBJECT TO CHANGE W I THOUT NOTI CE" 51 " ALL DI M ENSI ONS AND DESI GN CRI TERI A 20 250 (91316") ( 27116" ) 444 SAFE (1712") 861 339 (1338") ( 331516" ) 444 SAFE (1712") 386 339 (13516") ( 15316" ) 444 SAFE (17716") 384 463 320 463 320 463 329 (1518") (1814") (1258") (1814") (1258") (1814") (121516") 2742 (1071516") PLAN VIEW - ADJACENT UNITS (REQUIRED MINIMUM SERVICE AREA) ( 611316" ) 89 (312") 3 ( ) 4" 89 (312") ( 6" ) 20 13 ( ) 16" PAGE 4 OF 4 304 (12") 25.4mm (1") THROUGH-HOLE-DIAMETER 152 11 18mm ( 16") RECESS DEPTH 25.4mm (1") THROUGH-HOLE-DIAMETER FI LE NO.177674 REV.0 THI RD ANGLE 1 ( 918" ) 2