Diebold® 5500 lobby cash dispenser front load with 13mm (1/2") UL

advertisement
®
R
DIEBOLD
5500 LOBBY CASH DISPENSER
L1216
FRONT LOAD- WITH 13mm 1
(2") UL SAFE
CALL 1-800-999-3600
CONSULT WITH DIEBOLD INSTALLATION/SERVICE
BRANCH FOR ADDITIONAL DETAILS AND INFORMATION.
PLEASE SEE PLANNING AND SITE PREPARATION GUIDE
TP-821762-001.
(1712")
(
DI
M ENSI
ONS I
NI
NCHES)
CONSUMER ACCESS DIMENSIONS
732
A
(
281316"
)
DI
M ENSI
ONS I
N MI
LLI
M ETRES
444
TOP OF DISPLAY
HEIGHT
DEPTH
1316mm
135mm
13
16")
B
TOP FUNCTION KEY
C
KEYPAD ("5" KEY)
D
RECEIPT PRINTER
E
ActivDispense
F
HEADPHONE JACK
(51
(714")
1213mm
92mm
(4734")
(358")
966mm
78mm
(3116")
(38")
853mm
0
(33916")
702mm
0
(2758")
37mm
1046mm
G
1
THI
RD ANGLE
PROJECTI
ON
FINGER PRINT READER
993mm
28mm
1
(39"
16")
1
(1 8")
874mm
H
CARD READER
PLAN VIEW
HEIGHT - FROM BOTTOM OF SAFE
DEPTH - FROM FRONT EDGE OF FASCIA
463
568
(2238")
A
404
B
D
H
E
1402
G
1402
C
POWER CORD - LENGTH
2210mm (87") FROM SIDE
OF UNIT
383
(15116")
38
0mm TO 76mm (0" TO 3") LEVELING
(112")
664
FRONT VIEW
(2618")
732
(281316")
SIDE VIEW
0m m TO 76m m (
0"TO 3"
)LEVELI
NG
F
(
55316"
)
(1578")
(
55316"
)
PAGE 1 OF 4
SUBJECT TO CHANGE W I
THOUT NOTI
CE"
FI
LE NO.177663 REV.1
0
7
16")
(34
(1814")
"
ALL DI
M ENSI
ONS AND DESI
GN CRI
TERI
A
(1716")
3
16")
463
(18 4")
(41
CONDUIT AND JUNCTION BOX
POWER REQUIREMENTS
REQUIREMENTS
THE CASH DISPENSER REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER
RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND
(CONDUIT GROUND IS NOT ACCEPTABLE). THE CASH DISPENSER WILL PROVIDE A POWER
CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS
25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO
1
102mm (4") SQ. X 54mm
(218")
DP. JUNCTION BOX (ALL BY OWNERS E.C.). DIEBOLD TO
SPECIFIED BELOW.
PROVIDE FLAT COVER WITH TAMPER SWITCH.
CHOOSE AND SUPPLY THE PROPER POWER FOR THE SITE:
WHEN "SECUROMATIC" AFTER HOUR DEPOSITORY IS TO BE CONNECTED
100-127 VAC (+6%, -10%) AT 50 (±1%) Hz, SINGLE-PHASE
TO CASH DISPENSER, OWNERS E.C. TO RUN 19mm 3
(4") METAL CONDUIT FROM 102mm
2
100-127 VAC (+6%, -10%) AT 60 (±1%) Hz, SINGLE-PHASE
1
(4") SQ. X 54mm (2 8") DP. JUNCTION BOX TO AFTER HOUR DEPOSITORY.
3
(4")
OWNERS E.C. TO RUN 19mm
3
200-240 VAC (±10%) AT 50 (±1%) Hz, SINGLE-PHASE
LIQUID TIGHT FLEX METAL CONDUIT OR 19mm
200-240 VAC (±10%) AT 60 (±1%) Hz, SINGLE-PHASE
3
(4")
RIGID
POWER TO THE CASH DISPENSER MUST BE A DEDICATED SERVICE AND PROTECTED
BY A SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT
CONDUIT FROM JUNCTION BOX TO CABLE CONNECTING PLATE.
3
19mm (
4") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 102mm (4") SQ.
BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT
BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE.
X 54mm (218") DP. JUNCTION BOX WITH RECEPTACLE WITHIN 2210mm (87") OF SIDE
4
100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 15 AMPERES
CONNECTING PLATE. BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY
(ALL BY OWNERS E.C.) (SEE POWER REQUIREMENTS).
200-240 VAC (~10%) SERVICE, DISCONNECT AT 10 AMPERES
THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE
5
(
DI
M ENSI
ONS I
NI
NCHES)
DI
M ENSI
ONS I
N MI
LLI
M ETRES
OWNERS E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN
POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO
CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH 2210mm (87")
FROM SIDE OF UNIT.
SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11.
POWER USAGE
A
A
NOTE:
MACHINE STATUS
WITH BATTERY
JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF CONNECTING
CHARGING
PLATE. (LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT).
LOCATE IN AN EASILY ACCESSIBLE AREA.
BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW
CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH EXPOSED
CONDUIT FOR EXISTING CONSTRUCTION.
IDLE (NO TRANSACTION)
60 WATTS
85 WATTS
TRANSACTION (DISPENSE
IN PROGRESS)
95 WATTS
120 WATTS
CONFIGURATION
A
ALL-IN-ONE PROCESSOR, MOTORIZED CARD READER, RECEIPT PRINTER, AND
4 CASSETTE DISPENSER.
THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE
CASH DISPENSER, AND THE TYPE OF TRANSACTION THE CASH DISPENSER IS PERFORMING.
VALUES ABOVE ARE BASED ON MEASURED AVERAGES FOR THE CONFIGURATION LISTED.
PHYSICAL SECURITY
HEAT OUTPUT CONFIGURATION
THE SECURITY SAFE MEETS THE BANK PROTECTION ACT 82 STAT 295,
205 BTU/HR IDLE
325 BTU/HR DISPENSING
A
12 USC 882, AND MEETS THE ATTACK TEST PER UL 291-15. THE SAFE DOOR
HAS A POSITIVE RELOCKING FEATURE. THE SAFE DOOR IS CONTROLLED BY A
A
GROUP 2 COMBINATION LOCK WITH OR WITHOUT KEYLOCKING DIAL CAPABILITY
WITH BATTERY
CHARGING
290 BTU/HR IDLE
410 BTU/HR DISPENSING
OR OPTIONAL ELECTRONIC LOCK.
OPERATING ENVIRONMENT
ALARM PROTECTION
SAFE LOCATION
0°C TO 50°C (32°F TO 122°F)*
*(REQUIRES SOLID STATE DRIVE (SSD) IN ActivCore PROCESSOR.
THE UL-LISTED SAFE IS EQUIPPED WITH A DOOR SAFE OPEN SWITCH BY DEFAULT.
IF A HARD DISK DRIVE (HDD) DRIVE IS USED, THE MAX OPERATING
PROJECTI
ON
TEMPERATURE IS REDUCED TO 40°C ( 104°F)
AND A BOLTWORK POSITION SENSOR, AS WELL AS A BASIC ALARM PACKAGE.
RELATIVE HUMIDITY (NON-CONDENSING )
SIGNAL CABLE RUN CONSTRAINTS
20 TO 80% AT 32º C (90º F),
20 TO 55% AT 40º C (104º F)
THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL
CABLE RUN WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN.
SEPARATION FROM OTHER CABLES
BELOW 2 KVA
TYPE OF ELECTRICAL RUN
2-5 KVA
ABOVE 5 KVA
127mm (5")
127mm (5")
WEIGHT OF UNIT
490kg (1080 LBS.) APPROXIMATE.
FLUORESCENT, NEON OR INCANDESCENT
127mm (5")
LIGHTING FIXTURES
ACTUAL WEIGHT OF THE TERMINALWILL DEPEND ON THE
CONFIGURATION OF THE TERMINAL COMPONENTS AND OPTIONS
127mm (5")
UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT
UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT
WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT
64mm
POWER LINES IN GROUNDED CONDUIT WITH SIGNAL
CABLES IN GROUNDED CONDUIT
30mm (1
(212")
3
16")
305mm (12") 610mm (24")
152mm (6")
76mm (3")
305mm (12")
152mm (6")
SIGNAL CABLE INSTALLATION CONSTRAINTS
RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE POWER AND
LIGHTING CABLE, SIGNAL CABLES HAVE SMALL CONDUCTORS AND LIGHT INSULATION AND WILL NOT
WITHSTAND AS MUCH STRAIN IN INSTALLATION.
463
(1814")
(138")
79
(318") (318")
(138")
75
1
2
(
3"
)
AIR VENTS
89
89
286
1
(3 2")
(1114")
5
3
664
(2618")
REAR VIEW
SIDE VIEW
(
55316"
)
1402
1082
(
42916"
)
1
0m m TO 76m m (
0"TO 3"
)LEVELI
NG
1231
36
4
(
4812"
)
AIR VENTS
(
138"
)
4
829
SUBJECT TO CHANGE W I
THOUT NOTI
CE"
(281316")
AIR VENTS
(312")
"
ALL DI
M ENSI
ONS AND DESI
GN CRI
TERI
A
732
35
79
(
3258"
)
PAGE 2 OF 4
35
FI
LE NO.177663 REV.1
THI
RD ANGLE
A BASIC SENSOR PACKAGE IS AVAILABLE THAT INCLUDE A TEMPERATURE SENSOR
®
R
DIEBOLD
5500 LOBBY CASH DISPENSER
FRONT LOAD- WITH 13mm 1
(2") UL SAFE
CALL 1-800-999-3600
250
(91316")
89
89
(312")
(312")
20
444
1474
594
(
2338"
)
(
2914"
)
(
28"
)
RECOMMENDED SERVICE AREA
325
743
711
FOR SPECIAL BUILDING CONDITIONS.
(
1234"
)
(2")
(
6"
)
51
INCREASE IN INSTALLATION AND SERVICE TIME.
CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH
152
INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA
LESS THAN THE RECOMMENDED AREA MAY RESULT IN AN
860
(1712")
ALL ELECTRICAL AND DATA CABLES
PROJECTI
ON
384
463
329
(1518")
(1814")
(121516")
1176
(46516")
PLAN VIEW
711
743
(28")
(2914")
20
(1578")
1538
HEIGHT OF SPACE IN FRONT OF TERMINAL SHOULD ALLOW A
PERSON TO STAND AND SERVICE THE TERMINAL
SIDE VIEW
(RECOMMENDED SERVICE AREA )
1640
(1338")
13
(
16")
(
64916"
)
403
(
60916"
)
340
VARI
ABLE
SUBJECT TO CHANGE W I
THOUT NOTI
CE"
"
ALL DI
M ENSI
ONS AND DESI
GN CRI
TERI
A
PAGE 3 OF 4
( RECOMMENDED SERVICE AREA )
FI
LE NO.177663 REV.1
THI
RD ANGLE
MUST ENTER UNIT IN THIS AREA
(
58116"
)
622
(2412")
3
(
)
4"
304
(111516")
(
3378"
)
FOR INSTALLATION AND SERVICE. DIMENSIONS SHOWN
MAY BE INCREASED WHEREVER POSSIBLE TO IMPROVE
20
SHOWN IS THE MINIMUM/RECOMMENDED AREA REQUIRED
13
(
)
16"
NOTE:
(
DI
M ENSI
ONS I
NI
NCHES)
DI
M ENSI
ONS I
N MI
LLI
M ETRES
RECOMMENDED SERVICE AREAS
444 SAFE
33
(1712")
33
(1516")
378
(1516")
NOTES:
FOR ADDED SECURITY:
IT IS RECOMMENDED THAT THE CASH DISPENSER SAFE BE SECURED TO THE FLOOR WITH
ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE METHOD FOR
124
1
(
478"
)
74
(
278"
)
(1478")
1
YOUR INSTALLATION.
ANCHORING THE CASH DISPENSER TO CONCRETE FLOORS:
IT IS RECOMMENDED THAT THE CASH DISPENSER BE ANCHORED TO CONCRETE FLOORS
408
(
16116"
)
508
WHENEVER POSSIBLE. DIEBOLD RECOMMENDS USING A M20 OR 19mm 3
(4") ANCHOR BOLT THAT
IS 203mm (8") LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 102mm
(4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM THICKNESS.
ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES. IF THE TERMINAL IS
EQUIPPED WITH LEGS, THE LEVELING LEGS MUST BE REMOVED BEFORE THE TERMINAL IS
ANCHORED. REFER TO VIEW "A" AND "B" FOR ADDITIONAL DETAILS.
2
(
20"
)
664 SAFE
(
2618"
)
(
DI
M ENSI
ONS I
NI
NCHES)
DI
M ENSI
ONS I
N MI
LLI
M ETRES
2
CABLE ENTRY
SEE NOTE
ANCHORING THE CASH DISPENSER TO WOOD FLOORING:
CASH DISPENSERS INSTALLED ON WOOD FLOORS OR FLOORS SUPPORTED BY WOODEN BEAMS
CAN BE SECURED BY A MACHINE-THREADED NUT AND BOLT METHOD. IT IS PREFERRED THAT
THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS OR BEAMS FOR MAXIMUM HOLDING
2
CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO A LOCALLY FABRICATED
REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO PROVIDE ADDITIONAL
2
1
STRENGTH. THE REINFORCEMENT PLATE IS TYPICALLY 6mm (4") THICK. IT IS IMPORTANT TO
NOTE THAT THE OVERALL HOLDING CAPACITY OF A WOOD FLOOR WILL BE LESS THAN THAT
OF CONCRETE FLOORS.
1
1
ANCHORING THE CASH DISPENSER TO STEEL FLOORS:
CASH DISPENSER INSTALLED ON STEEL FLOORS CAN BE SECURED BY A MACHINE-THREADED
METHOD. IT IS PREFERABLE THAT THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS
OR BEAMS FOR MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO
A LOCALLY FABRICATED REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO
PROVIDE ADDITIONAL STRENGTH. THE COMBINED BACKING PLATE AND FLOOR THICKNESS MUST
350
(1334")
52
42
(158")
(2116")
1 (4) 14mm
9
(
16")
1
BE AT LEAST 13mm (2").
DIA. LEVELING LEG HOLES
2 (4) 25.4mm (1") DIA. FLOOR MOUNTING HOLES
CABLE ENTRY NOTE:
PROJECTI
ON
ELECTRICAL AND DATA CABLING ENTERS THE ATM THROUGH
A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE. CABLES
ENTERING THE CASH DISPENSER PASS THROUGH THE POWER
CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL OF THE
SAFE OVER THE CABLE ENTRY OPENING. CABLING CAN ENTER
FROM THE SIDE OR OPTIONALLY FROM UNDER THE CASH
DISPENSER. THE CABLE ENTRY OPENING IS ON THE LEFT SIDE
OF THE SAFE AS VIEWED FROM THE FRONT OF THE CASH
DISPENSER.
3
OWNER'S INSTALLER TO DRILL (4) 19mm (4") DIA. X 203mm (8" MIN.) DEEP HOLES
IN CONCRETE FLOOR (RECOMMENDED DRILLING COMPLETELY THROUGH FLOOR
WHEN POSSIBLE AND TO BE SECURED TO THE CONCRETE FLOOR WITH (4)
3
19mm (
4")-10 X 203mm (8") LONG WEDGE ANCHORS (SUPPLIED BY OWNER'S INSTALLER)
DIEBOLD PART NUMBER 29-016376-000A, HILTI PART NUMBER 282520).
29mm (118") DIA. HOLE FOR
OPENINGS FOR POWER
CORD AND DATA CABLES
(SIDE ENTRY)
(
4"
)
N.
102 M I
(
8"
)
N.
203 M I
ALARM CABLES (SIDE ENTRY)
VIEW "A"
89
(312")
304
444
339
444
339
444
250
(111516")
(1712")
(1338")
(1712")
(1338")
(1712")
(91316")
20
89
(312")
3
(
)
4"
3
(
)
4"
MINIMUM CONCRETE DEPTH
102mm (4")
51
1474
384
463
320
463
320
463
329
(1518")
(1814")
(1258")
(1814")
(1258")
(1814")
(121516")
2742
(1071516")
PLAN VIEW - ADJACENT UNITS
(RECOMMENDED SERVICE AREA)
(
58116"
)
593
(
2338"
)
861
(
331516"
)
743
(
2914"
)
711
(2")
(
28"
)
SUBJECT TO CHANGE W I
THOUT NOTI
CE"
"
ALL DI
M ENSI
ONS AND DESI
GN CRI
TERI
A
VIEW "B"
MINIMUM HOLE DEPTH
203mm (8")
20
PAGE 4 OF 4
POWER CABLE PLATE
FI
LE NO.177663 REV.1
THI
RD ANGLE
PLAN VIEW - SAFE FLOOR