® R DIEBOLD 5500 LOBBY CASH DISPENSER L1216 FRONT LOAD- WITH 13mm 1 (2") UL SAFE CALL 1-800-999-3600 CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING AND SITE PREPARATION GUIDE TP-821762-001. (1712") ( DI M ENSI ONS I NI NCHES) CONSUMER ACCESS DIMENSIONS 732 A ( 281316" ) DI M ENSI ONS I N MI LLI M ETRES 444 TOP OF DISPLAY HEIGHT DEPTH 1316mm 135mm 13 16") B TOP FUNCTION KEY C KEYPAD ("5" KEY) D RECEIPT PRINTER E ActivDispense F HEADPHONE JACK (51 (714") 1213mm 92mm (4734") (358") 966mm 78mm (3116") (38") 853mm 0 (33916") 702mm 0 (2758") 37mm 1046mm G 1 THI RD ANGLE PROJECTI ON FINGER PRINT READER 993mm 28mm 1 (39" 16") 1 (1 8") 874mm H CARD READER PLAN VIEW HEIGHT - FROM BOTTOM OF SAFE DEPTH - FROM FRONT EDGE OF FASCIA 463 568 (2238") A 404 B D H E 1402 G 1402 C POWER CORD - LENGTH 2210mm (87") FROM SIDE OF UNIT 383 (15116") 38 0mm TO 76mm (0" TO 3") LEVELING (112") 664 FRONT VIEW (2618") 732 (281316") SIDE VIEW 0m m TO 76m m ( 0"TO 3" )LEVELI NG F ( 55316" ) (1578") ( 55316" ) PAGE 1 OF 4 SUBJECT TO CHANGE W I THOUT NOTI CE" FI LE NO.177663 REV.1 0 7 16") (34 (1814") " ALL DI M ENSI ONS AND DESI GN CRI TERI A (1716") 3 16") 463 (18 4") (41 CONDUIT AND JUNCTION BOX POWER REQUIREMENTS REQUIREMENTS THE CASH DISPENSER REQUIRES A SINGLE-PHASE, THREE-WIRE UNSWITCHED POWER RECEPTACLE. WIRING TO THE RECEPTACLE MUST INCLUDE A THIRD-WIRE EARTH GROUND (CONDUIT GROUND IS NOT ACCEPTABLE). THE CASH DISPENSER WILL PROVIDE A POWER CORD WITH A COUNTRY SPECIFIC POWER PLUG. THE POWER SUPPLIED MUST BE AS 25mm (1") METAL CONDUIT FROM ALARM CONTROL CABINET JUNCTION BOX TO 1 102mm (4") SQ. X 54mm (218") DP. JUNCTION BOX (ALL BY OWNERS E.C.). DIEBOLD TO SPECIFIED BELOW. PROVIDE FLAT COVER WITH TAMPER SWITCH. CHOOSE AND SUPPLY THE PROPER POWER FOR THE SITE: WHEN "SECUROMATIC" AFTER HOUR DEPOSITORY IS TO BE CONNECTED 100-127 VAC (+6%, -10%) AT 50 (±1%) Hz, SINGLE-PHASE TO CASH DISPENSER, OWNERS E.C. TO RUN 19mm 3 (4") METAL CONDUIT FROM 102mm 2 100-127 VAC (+6%, -10%) AT 60 (±1%) Hz, SINGLE-PHASE 1 (4") SQ. X 54mm (2 8") DP. JUNCTION BOX TO AFTER HOUR DEPOSITORY. 3 (4") OWNERS E.C. TO RUN 19mm 3 200-240 VAC (±10%) AT 50 (±1%) Hz, SINGLE-PHASE LIQUID TIGHT FLEX METAL CONDUIT OR 19mm 200-240 VAC (±10%) AT 60 (±1%) Hz, SINGLE-PHASE 3 (4") RIGID POWER TO THE CASH DISPENSER MUST BE A DEDICATED SERVICE AND PROTECTED BY A SAFETY QUICK-DISCONNECT DEVICE TO BREAK LINE VOLTAGE (SUCH AS A CIRCUIT CONDUIT FROM JUNCTION BOX TO CABLE CONNECTING PLATE. 3 19mm ( 4") METAL CONDUIT AND UNSWITCHED ELECTRICAL SUPPLY TO 102mm (4") SQ. BREAKER AT THE ELECTRICAL SERVICE PANEL. THE QUICK-DISCONNECT DEVICE (OR CIRCUIT BREAKER) MUST TURN OFF THE LINE VOLTAGE AT THE FOLLOWING AMPERAGE. X 54mm (218") DP. JUNCTION BOX WITH RECEPTACLE WITHIN 2210mm (87") OF SIDE 4 100-127 VAC (+6%, -10%) SERVICE, DISCONNECT AT 15 AMPERES CONNECTING PLATE. BOTTOM CONNECTION MUST BE COMPENSATED ACCORDINGLY (ALL BY OWNERS E.C.) (SEE POWER REQUIREMENTS). 200-240 VAC (~10%) SERVICE, DISCONNECT AT 10 AMPERES THE MODULE BULK POWER SUPPLY AND PROCESSOR POWER SUPPLY WILL PROVIDE 5 ( DI M ENSI ONS I NI NCHES) DI M ENSI ONS I N MI LLI M ETRES OWNERS E.C. TO SUPPLY COMPATIBLE RECEPTACLE FOR COUNTRY SPECIFIC PLUG-IN POWER CONDITIONING TO PREVENT THE TERMINAL FROM MALFUNCTIONING DUE TO CONNECTOR SUPPLIED WITH UNIT. POWER CORD LENGTH 2210mm (87") FROM SIDE OF UNIT. SHORT-TERM AC POWER FLUCTUATIONS AS OUTLINED IN EN61000-4-11. POWER USAGE A A NOTE: MACHINE STATUS WITH BATTERY JUNCTION BOXES MUST BE LOCATED WITHIN 2210mm (87") OF CONNECTING CHARGING PLATE. (LENGTH OF ELECTRICAL POWER CABLE PROVIDED WITH UNIT). LOCATE IN AN EASILY ACCESSIBLE AREA. BOXES CAN BE FLUSH MOUNTED WITH CONCEALED CONDUIT FOR NEW CONSTRUCTION OR BOXES CAN BE SURFACE MOUNTED WITH EXPOSED CONDUIT FOR EXISTING CONSTRUCTION. IDLE (NO TRANSACTION) 60 WATTS 85 WATTS TRANSACTION (DISPENSE IN PROGRESS) 95 WATTS 120 WATTS CONFIGURATION A ALL-IN-ONE PROCESSOR, MOTORIZED CARD READER, RECEIPT PRINTER, AND 4 CASSETTE DISPENSER. THE POWER USE DEPENDS ON THE NUMBER AND TYPE OF DEVICES PRESENT IN THE CASH DISPENSER, AND THE TYPE OF TRANSACTION THE CASH DISPENSER IS PERFORMING. VALUES ABOVE ARE BASED ON MEASURED AVERAGES FOR THE CONFIGURATION LISTED. PHYSICAL SECURITY HEAT OUTPUT CONFIGURATION THE SECURITY SAFE MEETS THE BANK PROTECTION ACT 82 STAT 295, 205 BTU/HR IDLE 325 BTU/HR DISPENSING A 12 USC 882, AND MEETS THE ATTACK TEST PER UL 291-15. THE SAFE DOOR HAS A POSITIVE RELOCKING FEATURE. THE SAFE DOOR IS CONTROLLED BY A A GROUP 2 COMBINATION LOCK WITH OR WITHOUT KEYLOCKING DIAL CAPABILITY WITH BATTERY CHARGING 290 BTU/HR IDLE 410 BTU/HR DISPENSING OR OPTIONAL ELECTRONIC LOCK. OPERATING ENVIRONMENT ALARM PROTECTION SAFE LOCATION 0°C TO 50°C (32°F TO 122°F)* *(REQUIRES SOLID STATE DRIVE (SSD) IN ActivCore PROCESSOR. THE UL-LISTED SAFE IS EQUIPPED WITH A DOOR SAFE OPEN SWITCH BY DEFAULT. IF A HARD DISK DRIVE (HDD) DRIVE IS USED, THE MAX OPERATING PROJECTI ON TEMPERATURE IS REDUCED TO 40°C ( 104°F) AND A BOLTWORK POSITION SENSOR, AS WELL AS A BASIC ALARM PACKAGE. RELATIVE HUMIDITY (NON-CONDENSING ) SIGNAL CABLE RUN CONSTRAINTS 20 TO 80% AT 32º C (90º F), 20 TO 55% AT 40º C (104º F) THE FOLLOWING CHART ITEMIZES THE PHYSICAL SPACING REQUIREMENTS OF THE SIGNAL CABLE RUN WITH RESPECT TO OTHER POWER AND ELECTRICAL EQUIPMENT CABLE RUN. SEPARATION FROM OTHER CABLES BELOW 2 KVA TYPE OF ELECTRICAL RUN 2-5 KVA ABOVE 5 KVA 127mm (5") 127mm (5") WEIGHT OF UNIT 490kg (1080 LBS.) APPROXIMATE. FLUORESCENT, NEON OR INCANDESCENT 127mm (5") LIGHTING FIXTURES ACTUAL WEIGHT OF THE TERMINALWILL DEPEND ON THE CONFIGURATION OF THE TERMINAL COMPONENTS AND OPTIONS 127mm (5") UNSHIELDED POWER LINE OR ELECTRICAL EQUIPMENT UNSHIELDED POWER LINES OR ELECTRICAL EQUIPMENT WITH SIGNAL CABLES ENCLOSED IN GROUNDED CONDUIT 64mm POWER LINES IN GROUNDED CONDUIT WITH SIGNAL CABLES IN GROUNDED CONDUIT 30mm (1 (212") 3 16") 305mm (12") 610mm (24") 152mm (6") 76mm (3") 305mm (12") 152mm (6") SIGNAL CABLE INSTALLATION CONSTRAINTS RELATIVE CARE IS REQUIRED WHEN INSTALLING SIGNAL CABLES IN CONDUITS, UNLIKE POWER AND LIGHTING CABLE, SIGNAL CABLES HAVE SMALL CONDUCTORS AND LIGHT INSULATION AND WILL NOT WITHSTAND AS MUCH STRAIN IN INSTALLATION. 463 (1814") (138") 79 (318") (318") (138") 75 1 2 ( 3" ) AIR VENTS 89 89 286 1 (3 2") (1114") 5 3 664 (2618") REAR VIEW SIDE VIEW ( 55316" ) 1402 1082 ( 42916" ) 1 0m m TO 76m m ( 0"TO 3" )LEVELI NG 1231 36 4 ( 4812" ) AIR VENTS ( 138" ) 4 829 SUBJECT TO CHANGE W I THOUT NOTI CE" (281316") AIR VENTS (312") " ALL DI M ENSI ONS AND DESI GN CRI TERI A 732 35 79 ( 3258" ) PAGE 2 OF 4 35 FI LE NO.177663 REV.1 THI RD ANGLE A BASIC SENSOR PACKAGE IS AVAILABLE THAT INCLUDE A TEMPERATURE SENSOR ® R DIEBOLD 5500 LOBBY CASH DISPENSER FRONT LOAD- WITH 13mm 1 (2") UL SAFE CALL 1-800-999-3600 250 (91316") 89 89 (312") (312") 20 444 1474 594 ( 2338" ) ( 2914" ) ( 28" ) RECOMMENDED SERVICE AREA 325 743 711 FOR SPECIAL BUILDING CONDITIONS. ( 1234" ) (2") ( 6" ) 51 INCREASE IN INSTALLATION AND SERVICE TIME. CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH 152 INSTALLATION AND SERVICE ACCESS. USE OF ANY AREA LESS THAN THE RECOMMENDED AREA MAY RESULT IN AN 860 (1712") ALL ELECTRICAL AND DATA CABLES PROJECTI ON 384 463 329 (1518") (1814") (121516") 1176 (46516") PLAN VIEW 711 743 (28") (2914") 20 (1578") 1538 HEIGHT OF SPACE IN FRONT OF TERMINAL SHOULD ALLOW A PERSON TO STAND AND SERVICE THE TERMINAL SIDE VIEW (RECOMMENDED SERVICE AREA ) 1640 (1338") 13 ( 16") ( 64916" ) 403 ( 60916" ) 340 VARI ABLE SUBJECT TO CHANGE W I THOUT NOTI CE" " ALL DI M ENSI ONS AND DESI GN CRI TERI A PAGE 3 OF 4 ( RECOMMENDED SERVICE AREA ) FI LE NO.177663 REV.1 THI RD ANGLE MUST ENTER UNIT IN THIS AREA ( 58116" ) 622 (2412") 3 ( ) 4" 304 (111516") ( 3378" ) FOR INSTALLATION AND SERVICE. DIMENSIONS SHOWN MAY BE INCREASED WHEREVER POSSIBLE TO IMPROVE 20 SHOWN IS THE MINIMUM/RECOMMENDED AREA REQUIRED 13 ( ) 16" NOTE: ( DI M ENSI ONS I NI NCHES) DI M ENSI ONS I N MI LLI M ETRES RECOMMENDED SERVICE AREAS 444 SAFE 33 (1712") 33 (1516") 378 (1516") NOTES: FOR ADDED SECURITY: IT IS RECOMMENDED THAT THE CASH DISPENSER SAFE BE SECURED TO THE FLOOR WITH ANCHOR BOLTS. USE THE FOLLOWING GUIDELINES TO DETERMINE THE APPROPRIATE METHOD FOR 124 1 ( 478" ) 74 ( 278" ) (1478") 1 YOUR INSTALLATION. ANCHORING THE CASH DISPENSER TO CONCRETE FLOORS: IT IS RECOMMENDED THAT THE CASH DISPENSER BE ANCHORED TO CONCRETE FLOORS 408 ( 16116" ) 508 WHENEVER POSSIBLE. DIEBOLD RECOMMENDS USING A M20 OR 19mm 3 (4") ANCHOR BOLT THAT IS 203mm (8") LONG. CONCRETE FLOORS OR CONCRETE BASES MUST BE A MINIMUM OF 102mm (4") THICK FOR ANCHORING TO BE EFFECTIVE. THERE IS NO LIMIT FOR MAXIMUM THICKNESS. ANCHOR BOLTS MUST BE USED IN ALL AVAILABLE ANCHOR HOLES. IF THE TERMINAL IS EQUIPPED WITH LEGS, THE LEVELING LEGS MUST BE REMOVED BEFORE THE TERMINAL IS ANCHORED. REFER TO VIEW "A" AND "B" FOR ADDITIONAL DETAILS. 2 ( 20" ) 664 SAFE ( 2618" ) ( DI M ENSI ONS I NI NCHES) DI M ENSI ONS I N MI LLI M ETRES 2 CABLE ENTRY SEE NOTE ANCHORING THE CASH DISPENSER TO WOOD FLOORING: CASH DISPENSERS INSTALLED ON WOOD FLOORS OR FLOORS SUPPORTED BY WOODEN BEAMS CAN BE SECURED BY A MACHINE-THREADED NUT AND BOLT METHOD. IT IS PREFERRED THAT THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS OR BEAMS FOR MAXIMUM HOLDING 2 CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO A LOCALLY FABRICATED REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO PROVIDE ADDITIONAL 2 1 STRENGTH. THE REINFORCEMENT PLATE IS TYPICALLY 6mm (4") THICK. IT IS IMPORTANT TO NOTE THAT THE OVERALL HOLDING CAPACITY OF A WOOD FLOOR WILL BE LESS THAN THAT OF CONCRETE FLOORS. 1 1 ANCHORING THE CASH DISPENSER TO STEEL FLOORS: CASH DISPENSER INSTALLED ON STEEL FLOORS CAN BE SECURED BY A MACHINE-THREADED METHOD. IT IS PREFERABLE THAT THE HARDWARE BE ATTACHED THROUGH SUPPORTING POSTS OR BEAMS FOR MAXIMUM HOLDING CAPACITY. ADDITIONALLY, THIS HARDWARE MUST ATTACH TO A LOCALLY FABRICATED REINFORCEMENT PLATE INSTALLED UNDERNEATH THE FLOOR TO PROVIDE ADDITIONAL STRENGTH. THE COMBINED BACKING PLATE AND FLOOR THICKNESS MUST 350 (1334") 52 42 (158") (2116") 1 (4) 14mm 9 ( 16") 1 BE AT LEAST 13mm (2"). DIA. LEVELING LEG HOLES 2 (4) 25.4mm (1") DIA. FLOOR MOUNTING HOLES CABLE ENTRY NOTE: PROJECTI ON ELECTRICAL AND DATA CABLING ENTERS THE ATM THROUGH A CABLE ENTRY OPENING ON THE SIDE OF THE SAFE. CABLES ENTERING THE CASH DISPENSER PASS THROUGH THE POWER CABLE PLATE WHICH IS ATTACHED TO THE INSIDE WALL OF THE SAFE OVER THE CABLE ENTRY OPENING. CABLING CAN ENTER FROM THE SIDE OR OPTIONALLY FROM UNDER THE CASH DISPENSER. THE CABLE ENTRY OPENING IS ON THE LEFT SIDE OF THE SAFE AS VIEWED FROM THE FRONT OF THE CASH DISPENSER. 3 OWNER'S INSTALLER TO DRILL (4) 19mm (4") DIA. X 203mm (8" MIN.) DEEP HOLES IN CONCRETE FLOOR (RECOMMENDED DRILLING COMPLETELY THROUGH FLOOR WHEN POSSIBLE AND TO BE SECURED TO THE CONCRETE FLOOR WITH (4) 3 19mm ( 4")-10 X 203mm (8") LONG WEDGE ANCHORS (SUPPLIED BY OWNER'S INSTALLER) DIEBOLD PART NUMBER 29-016376-000A, HILTI PART NUMBER 282520). 29mm (118") DIA. HOLE FOR OPENINGS FOR POWER CORD AND DATA CABLES (SIDE ENTRY) ( 4" ) N. 102 M I ( 8" ) N. 203 M I ALARM CABLES (SIDE ENTRY) VIEW "A" 89 (312") 304 444 339 444 339 444 250 (111516") (1712") (1338") (1712") (1338") (1712") (91316") 20 89 (312") 3 ( ) 4" 3 ( ) 4" MINIMUM CONCRETE DEPTH 102mm (4") 51 1474 384 463 320 463 320 463 329 (1518") (1814") (1258") (1814") (1258") (1814") (121516") 2742 (1071516") PLAN VIEW - ADJACENT UNITS (RECOMMENDED SERVICE AREA) ( 58116" ) 593 ( 2338" ) 861 ( 331516" ) 743 ( 2914" ) 711 (2") ( 28" ) SUBJECT TO CHANGE W I THOUT NOTI CE" " ALL DI M ENSI ONS AND DESI GN CRI TERI A VIEW "B" MINIMUM HOLE DEPTH 203mm (8") 20 PAGE 4 OF 4 POWER CABLE PLATE FI LE NO.177663 REV.1 THI RD ANGLE PLAN VIEW - SAFE FLOOR