Introduction to Mainframe Hardware

advertisement
Esra Ufacık, Mainframe Client Technical Specialist, IBM Turk – esrau@tr.ibm.com
Introduction to Mainframe Hardware
© 2012 IBM Corporation
Agenda
WHO uses Mainframes? And Why?
WHY the Mainframe delivers
ARCHITECTURE & Hardware Platform
HIGHLIGHTS of z196
z196 Book Concept
z196 Processor Unit Design
z196 Memory
z196 Connectivity
z196 RAS
BACKUP Slides
2
1
Definition of Mainframe
The Mainframe is a computer system designed to continuously
run very large, mixed workloads at high levels of utilization,
meeting user-defined service level objectives.
A Mainframe is what businesses use to host their commercial
databases, transaction servers, and applications that require a
greater degree of security and availability than is commonly
found on smaller-scale machines.
3
What is a Mainframe?
 A style of operation, applications, and operating system
facilities.
 Computers that can support thousands of applications and
input/output devices to simultaneously serve thousands of
users.
 A mainframe is the central data repository, or hub, in a
corporation‟s data processing center, linked to users through
less powerful devices such as workstations, terminals or
media devices.
 Can run multiple, but isolated operating systems
concurrently.
 Centralized control of resources.
 Optimized for I/O in all business-related data processing
applications supporting high speed networking and terabytes
of disk storage.
4
2
WHO uses
Mainframes?
And Why?
5
Sample of Customers Large and Small from Around the World
BANKS
OTHER FINANCIAL
INST.
RETAILERS
HEALTHCARE
UTILITIES /
ENERGY
Banco Itau
Bank of NZ
Bank of Montreal
[Slovenia]
[Peru]
Bank of China
Central Bank
of Russia
GOVERNMENTS
TRANSPORTATION
[Brazil]
Philippines
Savings Bank
OTHERS
[Gaming]
[Brazil]
[India]
Industrial
Bank of Korea
HOSTING
PROVIDERS
[Kazakhstan]
[USA]
[Belarusian Railways]
[Russian
Hydrometeorological
Research Institute]
[Germany]
[Vietnam]
[Manufacturer/USA]
6
3
Mainframe is the platform of choice for the top 25 global banks
Based on asset size, 96 out of the top 100 worldwide banks use System
z.1
50 out of the top 50 worldwide banks use System z.
72 out of the top 75 worldwide banks use System z.
For the latest generation of Mainframe;
$1.5 billion in R&D investment for z196
5,000+ IBMers worked more than three years, 31 million hours, 24hour development process across 18 IBM labs worldwide.
More than 40 IBM Fellows and Distinguished Engineers led this effort.
The zEnterprise 196 is the world‟s fastest and most scalable enterprise
system. 2
1 Based on „The Banker‟, System z install base and financial records
2 Based on 5.2GHz core processor speed
7
Workloads That Customers Run on Mainframe
Banking
Insurance
Retail
Healthcare
Public
Sector
Core Banking
Internet Rate
Quotes
On-line
Catalog
Patient Care
Systems
Electronic Tax
Processing
Wholesale
Banking –
Payments
Policy Sales &
Management
(e.g. Life,
Annuity, Auto)
Supply Chain
Management
On–line
Claims
Submission &
Payments
Web based
Social
Security
Customer
Care & Insight
Claims
Processing
Customer
Analysis
Fee payments
What is a workload?
The relationship between a group of applications and/or systems that are related across several
business functions to satisfy one or more business processes.
8
4
Academic Initiative
 1,067 Schools enrolled in the IBM System z Academic Initiative program, reaching students
in 67 countries (more than half outside the US).
 Mainframe contests continue to draw high school, college, and university student
participation around the world with 43,825 students from 32 countries.
 3,246 students from 40 countries have taken the The IBM System z Mastery Test. This test
is offered to students globally in 2011 at no cost.
http://www-05.ibm.com/tr/industries/education/mainframe-index.html
 IBM Academic Initiative System z resources (system access, course materials, education)
are available globally for universities and colleges.
 Systemzjobs.com (Job board) is a no-fee service that connects students and experienced
professionals seeking System z job opportunities with IBM System z clients, partners, and
businesses.
9
WHY the
Mainframe delivers
10
5
The Differentiation of Mainframe:
Why the Mainframe Is Just Another Computer, but a Different
Kind of Computer?
No other platform offers reliability, availability, scalability, resiliency, security, and management
features comparable to Mainframe, including:
 High levels of application and data availability
 Solid security and privacy
 Massive horizontal and vertical scalability
 Optimized operating environment
 Advanced virtualization capabilities
 Intelligent workload management
 Utilization of open and industry standards
 Unmatched platform for heritage (legacy) applications and data
 Specialty engines that integrate with existing assets
 World-class support
 Centralized control
 Continuing compatibility
11
Mainframe Operating System Heritage
 OS/360 -> OS/VS -> MVS -> MVS/SP -> MVS/XA -> MVS/ESA -> OS/390
-> z/OS
z/OS, IBM‟s premier zSeries operating system, is a highly secure, scalable,
high-performance enterprise operating system on which to build and deploy
traditional and Java-enabled applications, providing a comprehensive and
diverse application execution environment.
 DOS/360 -> DOS/VS -> VSE/SP -> VSE/ESA -> z/VSE
z/VSE enables proven, robust, and cost-effective solutions. z/VSE provides
sturdy batch and industrial strength on-line transaction processing (CICS)
capabilities. z/VSE can fit comfortably into a legacy of thrifty, dependable z/VSE
solutions.
 ACP -> TPF-> z/TPF
TPF is the platform driving the business-critical systems for many of
IBM's largest and most sophisticated users of online transaction
processing - airlines, railroads, hotels, financial services,
government, credit card and banking industries.
 CP/67 -> VM/370 -> VM/SP -> VM/XA -> VM/ESA -> z/VM
z/VM provides a highly flexible test and production environment for
enterprises deploying the latest e-business solutions. z/VM helps
enterprises meet their growing demands for multi-user server
solutions with support for a broad range of operating systems.
12
6
Mainframe Software
 Customer Information Control System (CICS®) - a
transaction processing environment that allows
applications to share information and to satisfy
customer requirements for information.
 Information Management System Transaction
Manager (IMS TM) – a transaction processing
environment and an application server
 Information Management System Database
Server (IMS DB) - a database system that is capable
of extremely high performance.
 DB2 - a full, functional relational database that
leverages all of the features of Mainframe and
z/OS to provide high availability and high
performance.
 WebSphere Application Server (WAS) – an
application server that runs on z/OS, and provides
true application portability between Mainframe and
distributed systems
13
Maximizing Utilization of Resources
High business
growth
 Up to 100% server utilization compared to 10-20% distributed
server utilization1
 Shared everything infrastructure allows for maximum utilization
of resources
z HIGH
SCALABILITY
Green strategy
Running out of
energy & space
– CPU, Memory, Network, Adapters, Cryptography, Devices
Lowers power
consumption for
each work unit
z GREEN
SAVINGS
Customer savings
Underutilized distributed servers
Up to 100% utilized Mainframe server
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
Typically single application per server
14
1 Source:
App
App
App
App
App
App
App
App
App
App
App
App
App
App
App
App
App
App
App
App
App
App
App
App
Multiple applications on one
Mainframe server
goMainframe.com Joe Clabby
7
Mainframe‟s Extreme Virtualization
Flexibility to respond
– Built into the architecture not an “add on” feature
VIRTUALIZATION
Mainframe
Hardware support:
10% of circuits are
used for virtualization
Deploy virtual servers in seconds
Highly granular resource sharing (<1%)
Each LPAR is one
Virtual Mainframe
PR/SM™
Hypervisor in
firmware
Add physical resources without taking system
down, scale out to 1000s of virtual servers
Do more with less: More virtual servers per core,
Share more physical resources across servers
LPAR – Up to 60 Logical partitions
Extensive virtual server life-cycle management
Hardware-enforced isolation
z/VM® – 100s of virtual servers – Shared Memory
Distributed Platforms
Limited per-core virtual server scalability
Physical server sprawl is needed to scale
The potential performance impact of the Linux server farm is
isolated from the other Logical partitions (LPAR)
Operational complexity increases as virtual server
images grow
VMWare, Xen, Virtual Iron focus only on x86, not
cross platform hardware management.
15
Chip Design Affects Virtualization Capabilities
Replicated Server Chip Design
Consolidated Server Chip Design
Cache
Cache
Workload
Chip Real Estate
Processor
Speed
Workload
Workload
Workload
Workload


Mixed workloads stress cache usage, requiring more
context switches
Working sets may be too large to fit in cache
“Fast” processor speed is not fully realized due to
cache misses
Workload
RAS
RAS

Workload
Chip Real Estate
Processor
Speed



System z cache is able to contain more working sets
Processor speed is optimized by increased cache usage
Additional RAS function is beneficial for mixed
workloads
Note: System representations are not to scale, proportions may vary based on generation of chip and model
16
8
A Fully virtualized infrastructure enables optimization to
maximize efficiency
Green strategy
Running out of
energy & space
Mainframe
EFFICIENCY
Consolidate the workloads of thousands of
distributed servers in a single system
Up to
Up to
Up to
Up to
80%
90%
90%
70%
Flexibility to
respond
EXTREME
VIRTUALIZATION
Reduction in energy consumption
Reduction in Floor Space
Reduction in SW License costs
Reduction in total cost of ownership
17
Mainframe Security
Reduce
business risk
Reducing risk – Protecting businesses
Mainframe
SECURITY
 Helping businesses:
 Protect from INTRUSION
– z/OS and z/VM Integrity Statement
 Protect DATA
– Built in encryption accelerators in every server
– FIPS-140-20 Level 4 certified encryption co-processors for highly secure encryption
 Ensure PRIVACY
– Access to all resources is controlled by an integrated central security manager
 Protect VIRTUAL SERVERS
– The only servers with EAL5 Common Criteria Certification for partitioning
 Respond to COMPLIANCE REGULATIONS
– Up to 70% in security audit savings
Up to 52% lower security administrative costs.
The Gold Standard for Security
18
9
Manage Risk with Mainframe Resiliency
Continuous
business
operations
Availability built in across the system
z HIGH
Mainframe
AVAILABILITY
AVAILABILITY
RELIABILITY
RELIABILITY
Designed to deliver continuous availability at the application level
Single Mainframe
Multiple
Mainframe
Multiple Data Centers
Site 1
Where mean time
between failure is
measured in decades
Designed for
application availability
of 99.999%
Site 2
Industry-leading
solution for
disaster recovery
 Avoiding the cost of downtime
 Maintaining productivity of users
 Ensuring access to critical
applications
 Open to clients 24/7
19
Summary of the Benefits of Mainframe
20
10
ARCHITECTURE
& Hardware
Platform
21
History
7th April 1964, Poughkeepsie NY: Announcement of the first general-purpose
computers:
A new generation of electronic computing equipment was introduced today
by International Business Machines Corporation. IBM Board Chairman
Thomas J. Watson Jr. called the event the most important product
announcement in the company's history.
The new equipment is known as the IBM System/360.
"System/360 represents a sharp departure from concepts of the past in
designing and building computers. It is the product of an international
effort in IBM's laboratories and plants and is the first time IBM has
redesigned the basic internal architecture of its computers in a decade.
The result will be more computer productivity at lower cost than ever
before. This is the beginning of a new generation - - not only of computers
- - but of their application in business, science and government ." *
* from the April 1964 announcement press release
22
11
Evolution of the Mainframe
IBM
IBM
System/360 System/370
1964
1970
IBM
IBM System
System/390
z900
1990
2000
IBM System
z990
IBM System
z9 EC
IBM System
z9 BC
IBM System
z10 EC
IBM System
z10 BC
IBM System
zEnterprise
196
IBM System
zEnterprise
114
2003
2005
2006
2008
2009
2010
2011
23
Conceptual diagram
OLD S/360
The central processor box contains the processors,
memory,1 control circuits and interfaces for
channels
RECENT
Current CPC designs are considerably more
complex than the early S/360 design. This
complexity includes many areas:
I/O connectivity and configuration
I/O operation
Partitioning of the system
24
12
Mainframe basic components
25
Mainframe is a balanced system design
System I/O Bandwidth
288 GB/Sec*
Balanced System
CPU, nWay, Memory,
I/O Bandwidth*
172.8 GB/sec*
96 GB/sec
Memory
3 TB**
24 GB/sec
1.5 TB**
512 GB
256
GB
300
64
GB
450
600
920
PCI for
1-way
1202
16-way
32-way
z196
54-way
64-way
* Servers exploit a subset of its designed I/O capability
** Up to 1 TB per LPAR
PCI - Processor Capacity Index
z10 EC
z9 EC
zSeries 990
80-way
Processors
zSeries 900
26
13
The virtualization concept
 The ability to share everything is based on one of the major concepts of the Mainframe. As
it is commonly used in computing systems, virtualization refers to the technique of hiding
the physical characteristics of the computing resources from users of those resources. For
example, each operating system in a logical partition of the Mainframe platform thinks it has
exclusive access to a real hardware image. The actual resources are shared with other
logical partitions. The virtualization concept is not an add-on to the platform. z/Architecture
contains many facilities in both the hardware and software that facilitate resource
virtualization. All elements of Mainframe enable the virtualization concept.
 Virtualizing the Mainframe environment involves creating virtual systems (logical partitions
and virtual machines), and assigning virtual resources, such as memory and I/O channels, to
them. Resources can be dynamically added or removed from these logical partitions
though operator commands.
 Dynamic logical partitioning and virtual machines increase flexibility, enabling selected
system resources such as processors, memory, and I/O components to be added and
deleted from partitions while they are actively in use. The ability to reconfigure logical
partitions dynamically enables system administrators to dynamically move resources from
one partition to another.
 Processor Resource/Systems Manager™ (PR/SM™) is a hypervisor integrated with all
Mainframe elements that maps physical resources into virtual resources so that many logical
partitions can share the physical resources.
27
PR/SM and logical partitions
 Processor Resource/Systems Manager is a
feature that enables logical partitioning of
the central processor complex (CEC).
PR/SM provides isolation between
partitions, which enables installations to
separate users into distinct processing
images, or to restrict access to certain
workloads where different security
clearances are required.
 Each logical partition operates as an
independent server running its own
operating environment. On the latest
Mainframe models, you can define up to 60
logical partitions running z/VM®, z/OS,
Linux on IBM Mainframe, z/TPF, and more
operating systems. PR/SM enables each
logical partition to have dedicated or
shared processors and I/O channels, and
dedicated memory (which you can
dynamically reconfigure as needed).
Either can be use to
configure the IOCDS
Support Elements (SEs)
28
14
LPAR concept
29
Logical Partitions (LPARs) or Servers
 A system programmer can assign
different operating environments to
each partition with isolation
 An LPAR can be assigned a number
of dedicated or shared processors.
 Each LPAR can have different
storage (CSTOR) assigned depending
on workload requirements.
 The I/O channels (CHPIDs) are
assigned either statically or
dynamically as needed by server
workload.
 Provides an opportunity to
consolidate distributed environments
to a centralized location
30
15
LPAR Logical Dispatching (Hypervisor)
 The next logical CP to be dispatched is
chosen from the logical CP ready queue
based on the logical CP weight.
 LPAR LIC dispatches the selected logical CP
(LCP5 of MVS2 LP) on a physical CP in the
CPC (CP0, in the visual).
 The z/OS dispatchable unit running on that
logical processor (MVS2 logical CP5) begins
to execute on physical CP0. It executes until
its time slice (generally between 12.5 and 25
milliseconds) expires, or it enters a wait, or it
is intercepted for some reason.
 In the visual, the logical CP keeps running
until it uses all its time slice. At this point the
logical CP5 environment is saved and
control is passed back to LPAR LIC, which
starts executing on physical CP0 again.
 LPAR LIC determines why the logical CP
ended execution and requeues the logical CP
accordingly. If it is ready with work, it is
requeued on the logical CP ready queue and
step 1 begins again.
31
HiperDispatch
 PR/SM and z/OS work in tandem to more efficiently use processor resources. HiperDispatch
is a function that combines the dispatcher actions and the knowledge that PR/SM has about
the topology of the server.
 Performance can be optimized by redispatching units of work to same processor group,
keeping processes running near their cached instructions and data, and minimizing transfers
of data ownership among processors/books.
 The nested topology is returned to z/OS by the Store System Information (STSI) 15.1.3
instruction, and HiperDispatch utilizes the information to concentrate logical processors
around shared caches (L3 at PU chip level, and L4 at book level), and dynamically optimizes
assignment of logical processors and units of work.
 z/OS dispatcher manages multiple queues, called affinity queues, with a target number of
four processors per queue, which fits nicely into a single PU chip. These queues are used to
assign work to as few logical processors as are needed for a given logical partition workload.
So, even if the logical partition is defined with a large number of logical processors,
HiperDispatch optimizes this number of processors nearest to the required capacity. The
optimal number of processors to be used are kept within a book boundary where possible.
32
16
LPAR
Characteristics
Summary
 LPARs are the equivalent of a
separate mainframe for most practical
purposes
 System administrators assign:
– Memory
– Processors
– CHPIDs either dedicated or shared
 Each LPAR runs its own operating
system
 Devices can be shared across several
LPARs
 Processors can be dedicated or
shared
 When shared each LPAR is assigned
a number of logical processors (up to
the maximum number of physical
processors)
 Each LPAR is independent
 This is done partly in the IOCDS and
partly in a system profile on the
Support Element (SE) in the CEC.
This is normally updated through the
HMC.
 Changing the system profile and
IOCDS will usually require a power-on
reset (POR) but some changes are
dynamic
 A maximum of 60 LPARs can be
defined in a z196 CPC
33
Terminology Overlap
34
17
The channel subsystem
One of the main strengths of the Mainframe computers is the ability to deal with a large
number of simultaneous I/O operations. The channel subsystem (CSS) has a major role in
providing this strength. The CSS manages the flow of information between I/O devices and
central memory. By doing so it relieves CPUs of the task of communicating directly with I/O
devices and permits data processing to proceed concurrently with I/O processing. The
channel subsystem is built on the following components:
 SAP (system assist processor) One of the Mainframe processor types, the SAP connects
the channel subsystem to the I/O devices that are attached to the channels. The SAP uses
the I/O configuration loaded in the Hardware System Area (HSA), and knows which device is
connected to each channel, and what is its protocol. The SAP manages the queue of I/O
operations passed to the channel subsystem by z/OS.
 Channels These are small processors that communicate with I/O control units (CU). They
manage the transfer of data between central storage and the external device.
 Channel path The channel subsystem communicates with I/O devices through channel
paths. If a channel is shared between multiple logical partitions, each logical partition
establishes a unique channel path to the each device using this channel.
 Subchannels A subchannel provides the logical appearance of a device to the program and
contains the information required for performing a single I/O operation. One subchannel is
provided for each I/O device addressable by the channel subsystem.
35
Channel Subsystem Relationship to Channels, Control Units and I/O
Devices
z196
Channel Subsystem
Controls queuing, de-queuing, priority management and
I/O identification of all I/O operations performed by LPARs
Partitions
Supports the running of an OS and allows CPs, memory
and Subchannels access to channels
Subchannels
This represents an I/O device to the hardware and is used
by the OS to pass an I/O request to the channel subsystem
Channels
CU
CU
The communication path from the channel subsystem to the
I/O network and connected Control Units/devices
CU
Control Units
Devices
(disk, tape, printers)
@
@
=
=
@
@
=
=
36
18
The Mainframe I/O Logical Channel Subsystem Schematic
H
I
P
E
R
V
I
S
O
R
H
S
A
Cache
MBA
SAP
Logical-channel
Subsystem 0
Cache
Cache
MBA
MBA
SAP
Logical-channel
Subsystem 1
Cache
MBA
SAP
Logical-channel
Subsystem 2
SAP
Logical-channel
Subsystem 3
Physical-Channel Subsystem
FICON Switch,
Control Unit,
Devices, etc.
-One FICON channel shared
by all LCSs and all partitions
-A MCSS-Spanned Channel Path
- One ESCON channel shared
by all partitions configured
to LCS15
- A MIF-shared channel path
ESCON Switch,
Control Unit,
Devices, etc.
37
Multiple channel subsystems and multiple subchannel sets
38
19
I/O Device addressing
39
System z I/O Connectivity

ESCON and FICON channels

Switches to connect peripheral devices to more than one CEC

CHPID addresses are two hex digits (FF / 256)

Multiple partitions can share CHPIDs (MIF)

I/O subsystem layer exists between the operating system and the CHPIDs

I/O control layer uses a control file IOCDS that translates physical I/O addresses into
devices numbers that are used by z/OS

Device numbers are assigned by the system programmer when creating the IODF and
IOCDS and are arbitrary (but not random!)

On modern machines they are three or four hex digits

example - FFFF = 64K devices can be defined
The ability to have dynamic addressing theoretically 7,848,900 maximum number of
devices can be attached.
40
20
MIF Channel Consolidation - example
statically
assigned
dynamically
assigned
41
HCD & Sample IOCP
ID
MSG2='ESRAU.IODF99 - 2011-02-15 22:05',SYSTEM=(2097,1), *
LSYSTEM=CECDCEA,
*
TOK=('CECDCEA',00800007C74E2094220520410111046F00000000,*
00000000,'11-02-15','22:05:20','ESRAU','IODF99')
RESOURCE PARTITION=((CSS(0),(PCF2GAR2,5),(PRDA,1),(PRDC,2),(PR*
DE,3),(PRDF,4),(*,6),(*,7),(*,8),(*,9),(*,A),(*,B),(*,C)*
,(*,D),(*,E),(*,F)),(CSS(1),(*,1),(*,2),(*,3),(*,4),(*,5*
),(*,6),(*,7),(*,8),(*,9),(*,A),(*,B),(*,C),(*,D),(*,E),*
(*,F)),(CSS(2),(*,1),(*,2),(*,3),(*,4),(*,5),(*,6),(*,7)*
,(*,8),(*,9),(*,A),(*,B),(*,C),(*,D),(*,E),(*,F)),(CSS(3*
),(*,1),(*,2),(*,3),(*,4),(*,5),(*,6),(*,7),(*,8),(*,9),*
(*,A),(*,B),(*,C),(*,D),(*,E),(*,F)))
CHPID PATH=(CSS(0),00),SHARED,PARTITION=((PRDA,PRDC),(=)),
*
CPATH=(CSS(0),00),CSYSTEM=CECDD6A,AID=0C,PORT=1,TYPE=CIB
...
CNTLUNIT CUNUMBR=FFFD,PATH=((CSS(0),08,09,0A,0B,0C,0D,0E,0F)),*
UNIT=CFP
IODEVICE ADDRESS=(FF90,007),CUNUMBR=(FFFD),UNIT=CFP
IODEVICE ADDRESS=(FF97,007),CUNUMBR=(FFFD),UNIT=CFP
42
21
PAV (Parallel Access Volume) & MA (Multiple Allegiance)
 IBM PAV enables System z to process multiple I/Os to same logical volume at once
 IBM Multiple Allegiance (concurrent execution of multiple requests from multiple hosts)
expands capability across multiple System z servers
 I/O Priority enables use of info from z/OS Workload Manager to manage I/O processing
order
I/O without PAV/MA
Appl. A
Appl. B
UCB 100
Appl. C
UCB 100
Appl. A
UCB 100
UCB Busy
One I/O to
one volume
at one time
I/O with PAV/MA
Appl. B
UCB 1FF
Alias to
UCB 100
Device Busy
Parallel Access
Volumes
100
Appl. C
UCB 100
UCB 100
100
Multiple
Allegiance
43
IBM PAV – Static, Dynamic & Hyper
 Static PAV: Aliases are always associated with the same Base Address.
 Dynamic PAV: Aliases are assigned up front but can be reassigned to any base address as
need dictates: WLM function call Dynamic Alias Management - reactive alias assignment
 HyperPAV: On demand/ Proactive alias assignment
I/O flow of PAV & MA
9000
8
8000
7
7000
6
6000
5
5000
4
4000
3
3000
2
2000
1
1000
0
I/O per second
Response (MS)
PAV Performance
9
<Queue
<Pend
<Connect
<Disc
I/O Rate>
0
NoPAV
PAV
44
22
Static PAV & Dynamic PAV
Aliases assigned to specific addresses
45
Hyper PAV
 Alias is taken from and returned to a pool instead of LCU.
 Define max. number of aliases per LCU in HCD.
 Every I/O Request is queued when all aliases allocated in the pool in the same LCU are
exhausted.
Aliases kept in pool for use as needed
46
23
ESCON Connectivity
 ESCON (Enterprise Systems Connection) is a data connection created by IBM commonly used to
connect their mainframe computers to peripheral devices.
 ESCON replaced the older, slower parallel Bus&Tag channel technology
 The ESCON channels use a director to support dynamic switching.
47
ESCON Director
ESCD
ESCD
48
24
Fiber Connectivity (FICON)
 FICON (for Fiber Connectivity) was the next generation high-speed input/output (I/O)
interface used by for mainframe computer connections to storage devices.
 FICON channels increase I/O capacity through the combination of a new architecture and
faster physical link rates to make them up to eight times as efficient as ESCON.
49
FICON Connectivity
50
25
ESCON vs FICON
 ESCON
- 20 Mbytes / Second
- Lots of “dead time”. One active request at a time.
- One target control unit
 FICON
- 800 Mbytes / Second
- Uses FCP standard
- Fiber Optic cable (less space under floor)
- Currently, up to 64 simultaneous “I/O packets” at a time with up to 64 different
control units
- Supports Cascading switches
51
Hardware Management Console
Mainframe hardware can be managed by using either the Support Elements
directly attached to the server or using the Hardware Management Console
(HMC), which is a desktop application providing the end user interface to control
and monitor the status of the system.
Working from an HMC, an operator, a system programmer, or IBM technical
personnel can perform basic operations on the Mainframe servers. The HMC is a
powerful console that can load and shut down system images as well as the
entire machine. Some of the common capabilities of the HMC are:
 Load the Mainframe hardware configuration.
 Load or reset a system image.
 Add and change the hardware configuration
(most of them dynamically).
 Access the hardware logs.
All these functions can be executed using a
browser interface in a totally secure environment.
52
26
Reserved processors & storage
Reserved processors are defined by the Processor Resource/Systems Manager (PR/SM) to
allow for a nondisruptive capacity upgrade. Reserved processors are like spare logical
processors, and can be shared or dedicated. Reserved CPs should be defined to a logical
partition to allow for nondisruptive image upgrades.
Reserved storage can optionally be defined to a logical partition, allowing a nondisruptive
image memory upgrade for this partition. Reserved storage can be defined to both central
and expanded storage, and to any image mode, except the coupling facility mode.
LPAR dynamic storage reconfiguration
Dynamic storage reconfiguration on z196 servers allows an operating system running in a
logical partition to add (nondisruptively) its reserved storage amount to its configuration, if
any unused storage exists. This unused storage can be obtained when another logical
partition releases some storage or when a concurrent memory upgrade takes place. With
dynamic storage reconfiguration, the unused storage does not have to be continuous.
53
HIGHLIGHTS
of z196
54
27
z196 Overview
 Machine Type
– 2817
 5 Models
– M15, M32, M49, M66 and M80
 Processor Units (PUs)
– 20 (24 for M80) PU cores per book
– Up to 14 SAPs per system, standard
– 2 spares designated per system
– Dependant on the H/W model - up to 15,32,49,66 or 80 PU
cores available for characterization
• Central Processors (CPs), Integrated Facility for Linux (IFLs),
Internal Coupling Facility (ICFs), Mainframe Application
Assist Processors (zAAPs), Mainframe Integrated
Information Processor (zIIP), optional - additional System
Assist Processors (SAPs)
– Sub-capacity available for up to 15 CPs
• 3 sub-capacity points
 Memory
– System Minimum of 32 GB
– Up to 768 GB per book
– Up to 3 TB for System and up to 1 TB per LPAR
• Fixed HSA, standard
• 32/64/96/112/128/256 GB increments
 I/O
– Up to 48 I/O Interconnects per System @ 6 GBps each
– Up to 4 Logical Channel Subsystems (LCSSs)
 STP - optional (No ETR)
55
zEnterprise 196 Functions and Features
(GA Driver 86 – August, 2010)
Five hardware models
Three subchannel sets per LCSS
Quad core PU chip
Up to 80 processors configurable as
CPs, zAAPs, zIIPs, IFLs, ICFs, or
optional SAPs
Increased capacity processors
Out of order instruction execution
Over 100 new and enhanced
instructions
Improved processor cache design
Up to 15 subcapacity CPs at capacity
settings 4, 5, or 6
Up to 3 TB of Redundant Array of
Independent Memory (RAIM)
Unified Resource Manager suites
Cryptographic enhancements
On Demand enhancements
Energy efficiencies
2 New OSA CHPIDs – OSX and OSM
8 slot, 2 domain I/O drawer
z196
Concurrent I/O drawer add, remove,
replace
FICON discovery and autoconfiguration
Doubled HiperSockets to 32
Physical Coupling Links increased to 80
Doubled Coupling CHPIDs to 128
CFCC Level 17
Optional water cooling
Optional High Voltage DC power
Static Power Save Mode
Optional Top Exist I/O cable exit
STP enhancements
zBX-002 with IBM Smart Analytics
Optimizer, IBM Blades
56
28
zEnterprise 196 Functions and Features (GA Driver 93 – September, 2011)
Additional Cryptographic enhancements
8 GBps PCIe interconnects
Additional STP enhancements
Doubled Coupling CHPIDs to 128
Improved PSIFB Coupling Link
Physical Coupling Links increased to 104
New 32 slot PCIe Based I/O Drawer
Increased granularity of I/O adapters
New form factor I/O adapters i.e FICON
Express8S and OSA-Expres4S
57
zEnterprise 114, 196 and zBX Enhancements - October 12, 2011)
zHPF enhancements
EAL5+ Certification for z196
GDPS® Support for zEnterprise
GDPS xDR support for z/VSE
GDPS reduced HyperSwap® impact and improved
scalability
New IBM Implementation Services for System z
New and revised zEnterprise Statements of Direction
zBX IEDN TOR 1 GbE optics for the customer network
Additional zBX 8 Gbps FCS optics for POWER7 and
System x blade connections to the customer SAN
z196
z114
zBX support for Windows on select System x blades
New DataPower XI50z firmware support
zBX support for AIX 7.1 on select POWER7 blades
Unified Resource Manager APIs
Unified Resource Manager dynamic discovery of storage
resources
z/VM 6.2 enhanced virtualization capabilities
IBM DB2 Analytics Accelerator
zBX
58
29
Design highlights
 Offer a flexible infrastructure
 Offer state-of-the-art integration capability
 Offer high performance
 Offer the high capacity and scalability
 Offer the capability of concurrent upgrades for processors, memory, and I/O
connectivity
 Implement a system with high availability and reliability
 Have broad internal and external connectivity offerings
 Provide the highest level of security in which every two PUs share a CP Assist for
Cryptographic Function (CPACF).
 Be self-managing and self-optimizing – IRD, Hiperdispatch
 Have a balanced system design
59
z196 Processor Design Basics
Logical View of Single Book
 Processor Design
– CPU (core)
• cycle time
• pipeline, execution order
• branch prediction
• hardware vs. millicode*
– Memory subsystem (nest)
• high speed buffers
(caches)
on chip, on book
private, shared
• buses
number, bandwidth
• latency
distance
speed of light
Memory
Shared Cache
Private
Cache
Private
Cache
CPU
CPU
Private
Cache
…
CPU
*executes complex instructions
60
30
Performance Drivers with z196
 Hardware
–Memory subsystem
• focus on keeping data “closer” to the processor unit
• new chip-level shared cache
• much larger book-level shared cache
–Processor
• Out-of-Order execution
• new instructions to allow for reduced processor quiesce effects
reduced cache misses reduced pipeline disruption
• up to 80 configurable processor units
• Total of 4 different uni speeds, 3 sub-capacity
 HiperDispatch
–exploits new cache topology
–reduced cross-book “help”
–better locality for multi-task address spaces
State benefits if you re-compile
(Run-time modules or to make use of out-of-order execution)
61
Hypervisor and OS Basics
 Hypervisor (PR/SM)
– Virtualization layer at OS level
– Distributes physical resources
• Memory
• Processors
Logicals dispatched on physicals
Dedicated
Shared
Affinities
 OS
– Virtualization layer at address space level
– Distributes logical resources
• Memory
• Processors
Tasks dispatched on logicals
 Enhanced cooperation
– HiperDispatch with z10 EC
• z/OS + PR/SM
Logical View of 2 books
Memory
Memory
L2 Cache
L2 Cache
L1
L1
CPU
CPU
…
L1
L1
L1
CPU
CPU
CPU
…
L1
CPU
PR/SM
LP1
LP2
TCBa
TCBb
…
z/OSi
LPn
TCBx
LP1
LP2
TCBa
TCBb
…
z/OSj
LPm
TCBx
62
31
z196 – Under the covers (Model M66 or M80)
Internal
Batteries
(optional)
Processor Books,
Memory, MBA and
HCA cards
Power
Supplies
Ethernet cables for
internal System LAN
connecting Flexible
2 x Support
Elements
(FSP) cage controller
cards
Service Processor
InfiniBand I/O
Interconnects
I/O cage
2 x Cooling
Units
I/O drawers
Fiber Quick Connect
(FQC) Feature
(optional)
FICON &
ESCON
FQC
63
z196 Water cooled – Under the covers (Model M66 or M80) front
view
Internal
Batteries
(optional)
Power
Supplies
Support
Elements
I/O cage
I/O drawers
Ethernet cables for
internal System LAN
connecting Flexible
Service Processor
(FSP) cage controller
cards
Processor Books,
Memory, MBA and
HCA cards
InfiniBand I/O
Interconnects
2 x Water
Cooling
Units
z196TLLB64
64
32
z196 System Upgrades:
Protecting your investments
z9 EC
M80
M49
z10 EC
M32
M15
Concurrent Upgrade
M66
 z196 to higher hardware z196
model
– Upgrade of z196 Models M15, M32,
M49 and M66 to M80 is disruptive
– When upgrading to z196 all the Books
are replaced
– Upgrade from Air to Water cooled not
available
 Any z9 EC to any z196
 Any z10 EC to any z196
65
z196 Architecture
 Continues line of upward-compatible Mainframe processors
 Rich CISC (Complex Instruction Set Computer) Instruction Set Architecture
(ISA)
– 984 instructions (762 implemented entirely in hardware)
– 24, 31, and 64-bit addressing modes
– Multiple address spaces robust inter-process security
– Multiple arithmetic formats
– Industry-leading virtualization support
• High-performance logical partitioning via PR/SM
• Fine-grained virtualization via z/VM scales to 1000‟s of images
– Precise, model-independent definition of hardware/software interface
 Architectural extensions for IBM z196
– 110+ new instructions added to improve compiled code efficiency
– Decimal floating point quantum exceptions
– New crypto functions and modes
– Virtual architectural level
66
*RISC = Reduced Instruction Set Computer
33
z196
Book Concept
67
Book design
 A z196 system has up to four books on a fully connected topology,
up to 80 processor units can be characterized, and up to 3 TB of
memory capacity. Memory has up to 12 memory controllers, using
5-channel redundant array of independent memory (RAIM)
protection, with DIMM bus cyclic redundancy check (CRC) error
retry. The 4-level cache hierarchy is implemented with eDRAM
(embedded) caches. Up until recently eDRAM was considered to
be too slow for this kind of use, however, a break-through in IBM
technology has negated that. In addition eDRAM offers higher
density, less power utilization, fewer soft-errors, and better
performance. Concurrent maintenance allows dynamic book add
and repair.
 The z196 server uses 45nm chip technology, with advancing low
latency pipeline design, leveraging high speed yet power efficient
circuit designs. The multichip module (MCM) has a dense
packaging, allowing modular refrigeration units (MRUs) cooling, or
as an option, water cooling. The water cooling option is
recommended as it can lower the total power consumption of the
server.
68
34
Book Layout
Backup Air Plenum
8 I/O FAN OUT
2 FSP
MCM @ 1800W
Refrigeration Cooled or
Water Cooled
16X DIMMs
100mm High
Fanout
Memory
Rear
DCA Power Supplies
3x DCA
11 VTM Card Assemblies
8 Vertical
3 Horizontal
Front
Cards
Memory
14X DIMMs
100mm High
Cooling
from/to MRU
69
z196 PU chip, SC chip and MCM
z196
Quad Core
PU CHIP
96 MB
SC CHIP
BOOK
Front View
Front View
Fanouts
MCM
70
35
z196 Cache / Book Topology
Fully connected 4 Book system:
Mem2 Mem1 Mem0
Book:
CP2
FBCs
CP1
SC1
CP3
CP0
FBCs
SC0
CP4
CP5
 The z196 Books are fully interconnected
in a point to point topology as shown in
the diagram
 96 total cores, 80way
 Total system cache
 768 MB shared L4 (eDRAM)
 576 MB L3 (eDRAM)
 144 MB L2 private (SRAM)
 19.5 MB L1 private (SRAM)
 Data transfers are direct between Books
via the Level 4 Cache chip in each
MCM.
 Level 4 Cache is shared by all PU chips
on the MCM
71
z196 Book Level Cache Hierarchy
PU
L1
L1
L1
PU
L1
L1
L1
L1
PU
L1
L1
L1
L1
PU
L1
L1
L1
L1
PU
L1
L1
L1
L1
PU
L1
L1
L1
L1
L1
1.5MB 1.5MB 1.5MB 1.5MB
L2
L2
L2
L2
1.5MB 1.5MB 1.5MB 1.5MB
L2
L2
L2
L2
1.5MB 1.5MB 1.5MB 1.5MB
L2
L2
L2
L2
1.5MB 1.5MB 1.5MB 1.5MB
L2
L2
L2
L2
1.5MB 1.5MB 1.5MB 1.5MB
L2
L2
L2
L2
1.5MB 1.5MB 1.5MB 1.5MB
L2
L2
L2
L2
24MB eDRAM
Inclusive L3
24MB eDRAM
Inclusive L3
24MB eDRAM
Inclusive L3
24MB eDRAM
Inclusive L3
24MB eDRAM
Inclusive L3
24MB eDRAM
Inclusive L3
LRU Cast-Out
CP Stores
Data Fetch Return
72
192MB eDRAM
Inclusive L4
2 SC Chips
3/2/2012
36
Cache levels and memory structure
73
Enhanced book availability
Book Add
– Model Upgrade by the addition of a single new book adding physical processors, memory,
and I/O Connections.
Continued Capacity with Fenced Book
– Make use of the LICCC defined resources of the fenced book to allocate physical resources
on the operational books as possible.
Book Repair
– Replacement of a defective book when that book had been previously fenced from the
system during the last IML.
Book Replacement
– Removal and replacement of a book for either repair or upgrade
74
37
z196
Processor Unit
Design
75
Mainframe Servers Continue to Scale with z196
96 engines
80-way
z196
77 engines
64-way
z10 EC
Maximum PCI
 Each new range continues to deliver:
– New function
– Unprecedented capacity to meet
consolidation needs
– Improved efficiency to further
reduce energy consumption
– Continues to delivering flexible and
simplified on demand capacity
– A Mainframe that goes beyond the
traditional paradigm
64 engines
54-way
z9 EC
48 engines
32-way
z990
z900
20 engines
16-way
Minimum PCI
z/OS release used for LSPR measurements
z196 measurements are for a xx-way
PCI - (Processor Capacity Index
z900
z/OS 1.6
z990
z/OS 1.6
z9 EC
z/OS 1.6
z10 EC
z/OS 1.8
z196
z/OS 1.11
76
38
z196 Continues the CMOS Mainframe Heritage
5.2
GHz
4.4
GHz
5000
Fastest
Microprocessor
In The Industry
4000
MHz
3000
1.7
GHz
2000
1000
300
MHz
420
MHz
550
MHz
1998
G5
1999
G6
770
MHz
1.2
GHz
0
1997
G4
 G4 – 1st full-custom CMOS S/390®
 G5 – IEEE-standard BFP; branch target prediction
 G6 – Copper Technology (Cu BEOL)
2000
z900
2003
z990
2005
z9 EC
 z900 – Full 64-bit z/Architecture
 z990 – Superscalar CISC pipeline
 z9 EC – System level scaling
2008
z10 EC
2010
z196
 z10 EC – Architectural extensions
 z196 – Additional Architectural
extensions and new cache
structure
77
z196 GHz Leadership
 Mainframe continues to grow frequency by
– Leveraging 45nm technology
– Advancing low latency pipeline design
– Leveraging high speed yet power-efficient circuit designs
 z196 achieves industry leadership 5.2 GHz operation
 High-frequency processor design is enabled by
– Innovative power-efficient circuit designs
– IBM‟s SOI silicon technology
– Leadership packaging technology including glass-ceramic MCMs
– Leadership cooling technology, with choice of MRU or chilled-water cooling
 GHz is especially important for CPU-intensive applications
 System performance is not linear with frequency
– Need to use LSPR + Mainframe capacity planning tools for real client /
workload sizing
 GHz is not the only dimension that matters
– Must balance frequency, pipeline efficiency, energy efficiency, cache/memory
design, I/O design
78
39
z196 Out of Order (OOO) Value
 OOO yields significant performance benefit for compute intensive apps through
–Re-ordering instruction execution
• Later (younger) instructions can execute ahead of an older stalled instruction
–Re-ordering storage accesses and parallel storage accesses
 OOO maintains good performance growth for traditional apps
Instrs
In-order core execution
Out-of-order core execution
1
2
L1 miss
L1 miss
3
4
5
Time
Execution
Time
Storage access
79
Superscalar processor
A scalar processor is a processor that is based on a single-issue architecture, which means that only
a single instruction is executed at a time. A superscalar processor allows concurrent execution of
instructions by adding additional resources onto the microprocessor to achieve more parallelism
by creating multiple pipelines, each working on its own set of instructions.
A superscalar processor is based on a multi-issue architecture. In such a processor, where
multiple instructions can be executed at each cycle, a higher level of complexity is reached,
because an operation in one pipeline stage might depend on data in another pipeline stage.
Therefore, a superscalar design demands careful consideration of which instruction sequences
can successfully operate in a long pipeline environment.
On the z196, up to three instructions can be decoded per cycle and up to five
instructions/operations can be executed per cycle. Execution can occur out of (program) order.
If the branch prediction logic of the microprocessor makes the wrong prediction, removing all
instructions in the parallel pipelines also might be necessary. Obviously, the cost of the wrong
branch prediction is more costly in a high-frequency processor design. For this reason, a variety of
history-based branch prediction mechanisms are used.
The branch target buffer (BTB) runs ahead of instruction cache pre-fetches to prevent branch
misses in an early stage. Furthermore, a branch history table (BHT) in combination with a pattern
history table (PHT) and the use of tagged multi-target prediction technology branch prediction offer
an extremely high branch prediction success rate.
80
40
Branch prediction
Because of the ultra high frequency of the PUs, the penalty for a wrongly predicted branch is
high. For that reason a multi-pronged strategy for branch prediction, based on gathered
branch history combined with several other prediction mechanisms, is implemented on each
microprocessor. The branch history table (BHT) implementation on processors has a large
performance improvement effect. Originally introduced on the IBM ES/9000 9021 in 1990,
the BHT has been continuously improved.
The BHT offers significant branch performance benefits. The BHT allows each PU to take
instruction branches based on a stored BHT, which improves processing times for
calculation routines. Besides the BHT, the z196 uses a variety of techniques to improve the
prediction of the correct branch to be executed. The techniques include:
 Branch history table (BHT)
 Branch target buffer (BTB)
 Pattern history table (PHT)
 BTB data compression
The success rate of branch prediction contributes significantly to the superscalar aspects of
the z196. This is because the architecture rules prescribe that, for successful parallel
execution of an instruction stream, the correctly predicted result of the branch is essential.
81
Wild branch
When a bad pointer is used or when code overlays a data area containing a pointer to code, a random
branch is the result, causing a 0C1 or 0C4 abend. Random branches are very hard to diagnose because
clues about how the system got there are not evident. With the wild branch hardware facility, the last
address from which a successful branch instruction was executed is kept. z/OS uses this
information in conjunction with debugging aids, such as the SLIP command, to determine where a wild
branch came from and might collect data from that storage location. This approach decreases the many
debugging steps necessary when looking for where the branch came from.
IEEE floating point
Over 130 binary and hexadecimal floating-point instructions are present in z196. They incorporate IEEE
Standards into the platform.
Translation look-aside buffer
The translation look-aside buffer (TLB) in the instruction and data L1 caches use a secondary TLB to
enhance performance. In addition, a translator unit is added to translate misses in the secondary TLB.
Instruction fetching, decode, and grouping
The superscalar design of the microprocessor allows for the decoding of up to three instructions per cycle
and the execution of up to five instructions per cycle. Both execution and storage accesses for
instruction and operand fetching can occur out of sequence.
Extended translation facility
Used in data conversion operations for data encoded in Unicode, causing applications that are enabled
for Unicode or globalization to be more efficient. These data-encoding formats are used in Web services,
grid, and on-demand environments where XML and SOAP technologies are used.
Instruction set extensions
Hexadecimal floating point, Immediate, Load, Cryptographic, Extended Translate Facility-3 and Assist
instructions,
82
41
z196 Compression and Cryptography Accelerator
 Data compression engine
– Static dictionary compression and expansion
– Dictionary size up to 64KB (8K entries)
• Local 16KB cache per core for dictionary
data
 CP Assist for Cryptographic Function
(CPACF)
– Enhancements for new NIST standard
– Complemented prior ECB and CBC
symmetric cipher modes with XTS, OFB,
CTR, CFB, CMAC and CCM
– New primitives (128b Galois Field multiply) for
GCM
Core 1
Core 0
2nd Level
Cache
IB OB TLB
Cmpr
Exp
TLB
16K
OB
IB
Cmpr
Exp
16K
 Accelerator unit shared by 2 cores
– Independent compression engines
– Shared cryptography engines
Crypto
Cipher
Crypto
Hash
83
Decimal floating point accelerator
The decimal floating point (DFP) accelerator function is present on each of the
microprocessors (cores) on the quad-core chip. Its implementation meets business
application requirements for better performance, precision, and function.
Base 10 arithmetic is used for most business and financial computation. Floating
point computation that is used for work typically done in decimal arithmetic has
involved frequent necessary data conversions and approximation to represent decimal
numbers. This has made floating point arithmetic complex and error-prone for
programmers using it for applications in which the data is typically decimal data.
Benefits
 Avoids rounding issues such as those happening with binary-to-decimal
conversions.
 Has better functionality over existing binary coded decimal (BCD) operations.
 Follows the standardization of the dominant decimal data and decimal operations in
commercial computing supporting industry standardization (IEEE 745R) of decimal
floating point operations. Instructions are added in support of the Draft Standard for
Floating-Point Arithmetic, which is intended to supersede the ANSI/IEEE Std 7541985.
84
42
Processor error detection and recovery
The PU uses something called transient recovery as an error recovery mechanism.
When an error is detected, the instruction unit retries the instruction and attempts to
recover the error. If the retry is not successful (that is, a permanent fault exists), a
relocation process is started that restores the full capacity by moving work to another
PU. Relocation under hardware control is possible because the R-unit has the full
architected state in its buffer
85
z196 Multi-Chip Module (MCM) Packaging
 96mm x 96mm MCM
– 103 Glass Ceramic layers
– 8 chip sites
– 7356 LGA connections
– 20 and 24 way MCMs
– Maximum power used by MCM is 1800W
PU 2
PU 1
PU 0
 CMOS 12s chip Technology
– PU, SC, S chips, 45 nm
– 6 PU chips/MCM – Each up to 4 cores
•
•
•
•
One memory control (MC) per PU chip
23.498 mm x 21.797 mm
1.4 billion transistors/PU chip
L1 cache/PU core
64 KB I-cache
128 KB D-cache
• L2 cache/PU core
1.5 MB
• L3 cache shared by 4 PUs per chip
24 MB
• 5.2 GHz
– 2 Storage Control (SC) chip
S10
S00
SC 1
SC 0
S11
S01
•
•
•
•
24.427 mm x 19.604 mm
1.5 billion transistors/SC chip
L4 Cache 96 MB per SC chip (192 MB/Book)
L4 access to/from other MCMs
– 4 SEEPROM (S) chips
PU 3
PU 4
PU 5
• 2 x active and 2 x redundant
• Product data for MCM, chips and other engineering
information
– Clock Functions – distributed across PU and SC chips
• Master Time-of-Day (TOD) function is on the SC
86
43
z196 Quad Core PU Chip Detail
 Up to Four active cores per chip
– 5.2 GHz
– L1 cache/ core
• 64 KB I-cache
• 128 KB D-cache
 12S0 45nm SOI
Technology
– 13 layers of metal
– 3.5 km wire
 1.4 Billion Transistors
 Chip Area – 512.3mm2
– 23.5mm x 21.8mm
– 8093 Power C4‟s
– 1134 signal C4‟s
– 1.5 MB private L2 cache/ core
 Two Co-processors (COP)
– Crypto & compression accelerators
– Includes 16KB cache
– Shared by two cores
 24MB eDRAM L3 Cache
– Shared by all four cores
 Interface to SC chip / L4 cache
– 41.6 GB/sec to each of 2 SCs
 I/O Bus Controller (GX)
– Interface to Host Channel Adapter (HCA)
 Memory Controller (MC)
– Interface to controller on memory DIMMs
– Supports RAIM design
87
z196 SC Chip Detail
 12S0 45nm SOI
Technology
L4 Cache
(24MB)
– 13 layers of metal
 Chip Area –
478.8mm^2
L4 Cache
(24MB)
– 24.4mm x 19.6mm
– 7100 Power C4‟s
– 1819 signal C4‟s
 1.5 Billion
Transistors
– 1 Billion cells for
eDRAM
 eDRAM Shared L4
Cache
Fabric
IOs
PLL Data Perv
ETR/
TOD Data
Clk
BitStack
L4 Controller
BitPerv Stack
Fabric
IOs
Perv
Repower
– 96 MB per SC chip
– 192 MB per Book
 6 CP chip interfaces
 3 Fabric interfaces
 2 clock domains
L4 Cache
(24MB)
L4 Cache
(24MB)
 5 unique chip voltage
supplies
88
44
z196 Microprocessor Summary
 Major advance in Mainframe processor design
– Deep, high-frequency (5.2 GHz) pipeline
– Aggressive out of order execution core
– 4-level cache hierarchy with eDRAM L3 and L4
 Synergy between hardware and software design
– z/Architecture (ISA - Instruction Set Architecture) extensions
– Compiler and micro-architecture co-optimization
– Robust performance gain on existing binaries (code)
 Major step up in processor performance
– Up to 40% performance gain on existing compute-intensive code
– Additional gains achievable with recompilation
89
z196 Processor Features
Model
Books/
PUs
CPs
IFLs
uIFLs
zAAPs
zIIPs
ICFs
SAPs
Std
Optional
SAPs
Std.
Spares
M15
1/20
0-15
0-15
0-14
0-7
0-7
0-15
3
0-4
2
M32
2/40
0-32
0-32
0-31
0-16
0-16
0-16
6
0-10
2
M49
3/60
0-49
0-49
0-48
0-24
0-24
0-16
9
0-15
2
M66
4/80
0-66
0-66
0-65
0-33
0-33
0-16
12
0-20
2
M80
4/96
0-80
0-80
0-79
0-40
0-40
0-16
14
0-18
2




z196 Models M15 to M66 use books each with a 20 core MCM (two 4-core and four 3-core PU chips)
Concurrent Book Add is available to upgrade from model to model (except to the M80)
z196 Model M80 has four books each with a 24 core MCM (six 4-core PU chips)
Disruptive upgrade to z196 Model M80 is done by book replacement
Notes: 1. At least one CP, IFL, or ICF must be purchased in every machine
2. One zAAP and one zIIP may be purchased for each CP purchased even if CP capacity is “banked”.
3. “uIFL” stands for Unassigned IFL
90
45
z196
Memory
91
Memory design
The z196 memory design also provides
flexibility and high availability
Memory assignment or allocation is done at
power-on reset (POR) when the system is
initialized. PR/SM is responsible for the
memory assignments.
PR/SM has knowledge of the amount of
purchased memory and how it relates to
the available physical memory in each of
the installed books. PR/SM has control
over all physical memory and therefore is
able to make physical memory available to
the configuration when a book is
nondisruptively added. PR/SM also
controls the reassignment of the content of
a specific physical memory array in one
book to a memory array in another book.
92
46
Large page support
 By default, page frames are allocated with a 4 KB size. The z196 supports a large page size
of 1 MB. The first z/OS release that supports large pages is z/OS V1R9.
 The translation look-aside buffer (TLB) exists to reduce the amount of time required to
translate a virtual address to a real address by dynamic address translation (DAT) when it
needs to find the correct page for the correct address space.
 It is very desirable to have one's addresses in the TLB. With 4 K pages, holding all the
addresses for 1 MB of storage takes 256 TLB lines. When using 1 MB pages, it takes only 1
TLB line. This means that large page size exploiters have a much smaller TLB footprint.
Hardware system area
 The hardware system area (HSA) is a non-addressable storage area that contains server
Licensed Internal Code and configuration-dependent control blocks. The HSA has a fixed
size of 16 GB and is not part of the purchased memory that is ordered and installed.
93
z196 Redundant Array of Independent Memory (RAIM)
z196 introduces the redundant array of
independent memory (RAIM). The RAIM
design detects and recovers from DRAM,
socket, memory channel or DIMM failures.
The RAIM design requires the addition of
one memory channel that is dedicated for
RAS
 The parity of the four “data” DIMMs are
stored in the DIMMs attached to the fifth
memory channel. Any failure in a memory
component can be detect and corrected
dynamically. This design takes the RAS of
the memory subsystem to another level,
making it essentially a fully fault tolerant
“N+1” design.
94
47
z196 Memory Offerings
 Purchase Memory – Memory available for
assignment to LPARs
Model
Standard
Memory GB
Flexible
Memory
GB
M15
32 - 704
NA
M32
32 - 1520
32 - 704
M49
32 - 2288
32 - 1520
M66
32 - 3056
32 - 2288
M80
32 - 3056
32 - 2288
 Hardware System Area – Standard 16 GB
outside customer memory for system use
 Standard Memory – Provides minimum
physical memory required to hold base
purchase memory plus 16 GB HSA
 Flexible Memory – Provides additional
physical memory needed to support
activation base customer memory and HSA
on a multiple book z196 with one book out of
service.
 Plan Ahead Memory – Provides additional
physical memory needed for a concurrent
upgrade (LIC CC change only) to a
preplanned target customer memory
95
z196
Connectivity
96
48
z196 I/O Infrastructure
Book 0
Book 1
Book 2
Book 3
Memory
Memory
Memory
Memory
PU
PU
PU
PU
PU
PU
PU
PU
FBC/L4 Cache
PU
FBC/L4 Cache
FBC/L4 Cache
PU
PU
HCA
PU
PU
PU
PU
PU
PU
HCA
PU
PU
PU
FBC/L4 Cache
PU
PU
PU
PU
HCA2-C
fanout
HCA
HCA
1st level
CopperCables
6 GBps
IFB-MP
RII
IFB-MP
IFB-MP
RII
2 GBps
mSTI
IFB-MP
IFB-MP
RII
500 MBps mSTI
IFB-MP
IFB-MP
IFB-MP
RII
2nd level
Embedded
333 MBps mSTI
2 GBps mSTI
1 GBps
mSTI
97
.
ESCON
ESCON
ESCON
ESCON
.
2GBps
mSTI
FPGA
ISC ISC ISC ISC
FPGA
.
Channels
Coupling Links
Channels
Ports
FICON Express8
2/4/8 Gbps
ISC-3
ESCON
OSA-Express3
10 GbE
z196 system structure for I/O
Acronym
Full name
AID
Adapter identification
CIB
Coupling using InfiniBand
HCA
Host Channel Adapter
MBA
Memory Bus Adapter
PSIFB
Parallel Sysplex using
InfiniBand
IFB-MP
InfiniBand Multiplexer
STI-MP
Self-Timed Interconnect
Multiplexer
98
49
z196 Channel Type and Crypto Overview
Supported Channel Types
 I/O Channels
FICON Express8S
FICON Express8
FICON Express4 (Carry forward on upgrade)
ESCON – Migrate Away (240 or fewer)
 Networking
OSA-Express4S
OSA-Express3
• 10 Gigabit Ethernet LR and SR
• Gigabit Ethernet LX and SX
• 1000BASE-T Ethernet
OSA-Express2 (Carry forward on upgrade)
• 1000BASE-T Ethernet
• Gigabit Ethernet LX and SX
HiperSockets (Define only)
 Coupling Links
InfiniBand Coupling Links
• 12x InfiniBand
• 1x InfiniBand
ISC-3 – Migrate Away (Peer mode only)
IC (Define only)
99
 Crypto
Crypto Express3
• Configurable Coprocessor / Accelerator
OSA Express 3 Configuration Options Summary
CHPID type
Purpose / Traffic
Operating Systems
OSD
All OSA features
z196, z10, z9, zSeries
Supports Queue Direct Input/Output (QDIO) architecture
TCP/IP traffic when Layer 3 (uses IP address)
Protocol-independent when Layer 2 (uses MAC address)
z/OS, z/VM
z/VSE, z/TPF
Linux on Mainframe
Non-QDIO; for SNA/APPN/HPR traffic
and TCP/IP “passthru” traffic
z/OS, z/VM
z/VSE
OSA-Integrated Console Controller (OSA-ICC)
Supports TN3270E, non-SNA DFT to IPL CPCs & LPs
z/OS, z/VM
z/VSE
OSM
1000BASE-T
z196 exclusive
OSA-Express for Unified Resource Manager
Connectivity to intranode management network (INMN)
from z196 to Unified Resource Manager functions
z/OS, z/VM
Linux on Mainframe*
OSN
GbE, 1000BASE-T
z196, z10, z9 exclusive
OSA-Express for NCP
Appears to OS as a device supporting CDLC protocol
Enables Network Control Program (NCP) channel-related functions
Provides LP-to-LP connectivity
OS to IBM Communication Controller for Linux (CCL)
z/OS, z/VM
z/VSE, z/TPF
Linux on Mainframe
OSX
10 GbE
z196 exclusive
OSA-Express for zBX
Connectivity and access control to intraensemble data network (IEDN) from
z196 to zBX
z/OS, z/VM
Linux on Mainframe*
OSE
1000BASE-T
z196, z10, z9, zSeries
OSC
1000BASE-T
z196, z10, z9, z990, z890
*IBM is working with its Linux distribution partners to include support in future Linux on
Mainframe distribution releases.
100
50
FICON Express8S – SX and 10KM LX in the PCIe I/O drawer
 For FICON, zHPF, and FCP environments
– CHPID types: FC and FCP
• 2 PCHIDs/CHPIDs
 Auto-negotiates to 2, 4, or 8 Gbps
 Increased performance compared to
FICON Express8
FLASH
2, 4, 8 Gbps
SFP+
HBA
ASIC
IBM
ASIC
2, 4, 8 Gbps
SFP+
HBA
ASIC
IBM
ASIC
 10KM LX - 9 micron single mode fiber
– Unrepeated distance - 10 kilometers (6.2
miles)
– Receiving device must also be LX
FLASH
PCIe
Switch
FC 0409 – 10KM LX, FC 0410 – SX
 SX - 50 or 62.5 micron multimode fiber
– Distance variable with link data rate and
fiber type
– Receiving device must also be SX
 2 channels of LX or SX (no mix)
 Small form factor pluggable (SFP) optics
– Concurrent repair/replace action for each SFP
LX
OR
SX
101
z196 HiperSockets – doubled the number
 High-speed “intraserver” network
Linux
LP2
z/OS
LP1
 Independent, integrated, virtual LANs
 Communication path – system memory
HiperSockets
 Communication across LPARs
– Single LPAR - connect up to 32 HiperSockets
 Support for multiple LCSS's & spanned channels
 Virtual LAN (IEEE 802.1q) support
z/VSE
LP3
L2
z/VM
LP5
 HiperSockets Network Concentrator
 Broadcast support for IPv4 packets
L3
z/VM
LP4
 IPv6
 HiperSockets Network Traffic Analyzer (HS NTA)
 No physical cabling or external connections required
102
51
z196 Coupling Link Options
Type
Description
Use
Link
data rate
Distance
IC
(ICP)
Internal Coupling
Channel
Internal
communication
Internal
speeds
NA
32
12x InfiniBand
z196 & z10
z196 & z10 to z9
6 GBps
3 GBps*
150 meters
(492 feet)
32
1x InfiniBand
z196 & z10
5 Gbps
or 2.5 Gbps**
10 km unrepeated
(6.2 miles)
100 km repeated
32
32
InterSystem
Channel-3
z196, z10, z9
2 Gbps
10 km unrepeated
(6.2 miles)
100 km repeated
48
48
InfiniBan
d
(CIB)
InfiniBan
d
(CIB)
ISC-3
(CFP)
z196
z196
Maximum Max links
z196
Max
CHPIDs
NA
128
CHPIDs
 Maximum of 16 InfiniBand fanouts are allowed, 2 links per fanout
 Maximum of 128 coupling CHPIDs (ICP, CIB, CFP) per server
Each InfiniBand link supports definition of multiple CIB CHPIDs, up to 16 per fanout
* z196 & z10 negotiate to 3 GBps when connected to a z9
** May negotiate to 2.5 Gbps when connected to a DWDM
Note: ICB-4 is not supported on z196
103
InfiniBand coupling links on z196 and z114 Summary
Type
Speed
Distance
Fanout
Cabling
50µ MM (OM3)
fiber
9µ SM fiber
12x InfiniBand
6 or 3 GBps
150 meters
HCA2-O
HCA3-O
1x InfiniBand
5 or 2.5 Gbps
10 km
HCA2-O LR*
HCA3-O LR
IFB
IFB
HCA2-O
Up to 16 CHPIDs – across 2 ports
IFB
IFB
HCA2-O LR*
Up to 16 CHPIDs – across 2 ports
IFB & IFB3
HCA3-O
IFB & IFB3
Up to 16 CHPIDs – across 2 ports**
IFB
IFB
IFB
HCA3-O LR
IFB
Up to 16 CHPIDs – across 4 ports**
 Ports exit from the front of a book/processor
drawer with HCAs. Unlike ISC-3 links, does not
use I/O card slots
 12x InfiniBand – z196, z114, z10, z9
– 6 GBps
• z196/z114 and z10
– 3 GBps
• z196/z114 & z10 to z9
• z9 to z9 connection not supported
 1x InfiniBand – z196/z114 and z10 (not available
for z9)
– 5 Gbps (Server to Server and with DWDM)
– 2.5 Gbps (with DWDM)
* For z114 carry forward only
** Performance considerations may reduce the number of CHPIDs
per port
104
52
Mainframe Crypto History
2001
2002
2003
2004
2005
2006
2007
2008
2009
2010
Cryptographic Coprocessor Facility (CCF)
Cryptographic
Coprocessor
Single Chip Module
G3, G4, G5, G6, z900, z800
OS/390
ICSF
PCI Cryptographic Coprocessor (PCICC)
G5, G6, z900, z800
PCI Cryptographic Accelerator (PCICA)
z800/z900
PCIX Cryptographic Coprocessor
(PCIXCC)
z990
z890
z990
z890
CP Assist for Cryptographic Functions z990
Crypto Express2
z890
z990/z890
z9 EC z9 BC
z10 EC/BC
z9 EC z9 BC
z10 EC/BC
Crypto Express3
z10 EC/BC z196
Cryptographic Coprocessor Facility – Supports “Secure key” cryptographic processing
PCICC Feature – Supports “Secure key” cryptographic processing
PCICA Feature – Supports “Clear key” SSL acceleration
PCIXCC Feature – Supports “Secure key” cryptographic processing
CP Assist for Cryptographic Function allows limited “Clear key” crypto functions from any CP/IFL
– NOT equivalent to CCF on older machines in function or Crypto Express2 capability
 Crypto Express2 – Combines function and performance of PCICA and PCICC
 Crypto Express3 – PCI-e Interface, additional processing capacity with improved RAS





105
Crypto Express3 2-P Physical View
Coprocessor #1
PCIe interfaces
Coprocessor #2
106
53
Crypto Express3 features highlights
 Virtualization: all logical partitions (LPARs) in all Logical Channel Subsystems (LCSSs) have
access to the Crypto Express3 feature, up to 32 LPARs per feature
 Designed for improved reliability, availability and serviceability (RAS)
 Executes its cryptographic functions asynchronously to a Central Processor (CP) operation
 Dynamic addition / configuration of cryptographic features to logical partitions without an
outage
 Dynamic power management to maximize RSA performance while keeping within
temperature limits of the tamper-responding package
 Secure code loading that enables the updating of functionality while installed in application
systems
 Lock-step-checking of dual CPUs for enhanced error detection and fault isolation of
cryptographic operations performed by coprocessor when a PCIe adapter is defined as a
coprocessor
 Updated cryptographic algorithms used in loading the Licensed Internal Code (LIC) with the
TKE workstation to keep in step with current recommendations for cryptographic strength
 Support for smart card applications using Europay, MasterCard, Visa specifications
 Health Monitoring of mesh, temperature, voltage, soft tamper and low battery. Monitoring is
internal to the card. Cannot be accessed or exploited by the customer
107
z196 New and exclusive cryptographic capabilities
 Elliptic Curve Cryptography Digital Signature Algorithm (ECC), an emerging public key algorithm
expected eventually to replace RSA cryptography in many applications. ECC is capable of providing
digital signature functions and key agreement functions. The new CCA functions provide ECC key
generation and key management and provide digital signature generation and verification functions
compliance with the ECDSA method described in ANSI X9.62 "Public Key Cryptography for the
Financial Services Industry: The Elliptic Curve Digital Signature Algorithm (ECDSA)". ECC uses
keys that are shorter than RSA keys for equivalent strength-per-key-bit; RSA is impractical at key lengths
with strength-per-key-bit equivalent to AES-192 and AES-256. So the strength-per-key-bit is substantially
greater in an algorithm that uses elliptic curves.
 ANSI X9.8 PIN security which facilitates compliance with the processing requirements defined in the new
version of the ANSI X9.8 and ISO 9564 PIN Security Standards and provides added security for
transactions that require Personal Identification Numbers (PIN).
 Enhanced Common Cryptographic Architecture (CCA), a Common Cryptographic Architecture (CCA)
key token wrapping method using Cipher Block Chaining (CBC) mode in combination with other
techniques to satisfy the key bundle compliance requirements in standards including ANSI X9.24-1 and
the recently published Payment Card Industry Hardware Security Module (PCI HSM) standard.
 Secure Keyed-Hash Message Authentication Code (HMAC), a method for computing a message
authentication code using a secret key and a secure hash function. It is defined in the standard FIPS 198,
"The Keyed-Hash Message Authentication Code". The new CCA functions support HMAC using
SHA-1, SHA-224, SHA-256, SHA-384, and SHA-512 hash algorithms. The HMAC keys are variablelength and are securely encrypted so that their values are protected.
 Modulus Exponent (ME) and Chinese Remainder Theorem (CRT), RSA encryption and decryption
with key lengths greater than 2048-bits and up to 4096-bits.
108
54
Certifications for Mainframe
z/VM
The Common Criteria
program developed by
NIST and NSA
establishes an
organizational and
technical framework to
evaluate the
trustworthiness of IT
Products and
protection profiles
 Common Criteria EAL4+
‒ z/VM 5.4 + RACF with
CAPP and LSPP –
designed for
compliance
‒ Plan to have z/VM 6.1
evaluated during 2011
z/OS
z/VM
Linux
Linux
Linux on Mainframe
Linux
z/OS
 Common Criteria EAL4+
Virtualization with partitions
‒ with CAPP and LSPP
Cryptography
‒ z/OS 1.10
z9 EC, z9 BC, z10 EC, z10 BC – EAL5
‒ z/OS 1.11 June 2010
‒ z/OS 1.12 under evaluation
 IdenTrust™ certification for
z/OS as a Digital Certificate
Authority
(PKI Services)
 Common Criteria
‒ Novell SUSE SLES9
and 10 certified at
EAL4+ with CAPP
‒ RHEL5 EAL4+ with
CAPP and LSPP
z196 - EAL5+
 Common Criteria EAL5
for Logical partitions
 FIPS 140-2 level 4
for Crypto Express2
See: www.ibm.com/security/standards/st_evaluations.shtml
109
z196
RAS
110
55
Mainframe overall RAS Strategy
…..Continuing our RAS focus helps avoid outages
Sources of Outages
Pre z9
-Hrs/Year/Syst-
Prior Servers
Impact of Outage
Unscheduled Outages
Scheduled Outages
Planned
Outages
Scheduled (CIE+Disrupt ive Pat ches + ECs)
Preplanning
requirements
Planned - (MES + Driver Upgrades)
Unscheduled (UIRA)
Power & Thermal
Management
z9 EC
 
 

Z10 EC




z196




Temperature = Silicon Reliability Worst Enemy
Wearout = Mechanical Components Reliability Worst Enemy.
111
Redundancy in Mainframe Hardware
Power
2x Power Supply
2x Power feed
Internal Battery Feature
Optional internal battery in
cause of loss of external
power)
Cooling, air & water-cooling options
Dynamic oscillator switchover
Processors
Multiprocessors
Spare PUs
Memory
RAIM
Chip sparing
Error Correction and Checking
Enhanced book availability
 The zEnterprise System continues to reduce
customer down time by focusing on all
sources of outages: unscheduled outages,
scheduled outages and planned outages.
Power and cooling requirements were reduced
while still managing reliability.
– Major new Memory design for preventing
outages
– Introducing new IO drawers technologies
designed for concurrent service
– Introducing Mainframe management to the
mixed computing environment
– Delivering Green functions and RAS together
112
56
Preventing All Outages
 Unscheduled Outages
 Advanced Memory RAIM (Redundant Array of Independent Memory) design
Enhanced Reed-Solomon code (ECC) – 90B/64B
Protection against Channel/DIMM failures
Chip marking for fast DRAM replacements
 Mirrored Key cache
 Improved chip packaging
 Improved condensation management
 Integrated TCP/IP checksum generation/checking
 Integrated EPO switch cover (protecting the switch during repair actions)
 Continued focus on Firmware
 Scheduled Outages
 Double memory data bus lane sparing (reducing repair actions)
 Single memory clock bus sparing
 Field Repair of interface between processor chip and cache chip and between
cache chips (fabric bus)
 Fast bitline delete on L3/L4 cache (largest caches)
 Power distribution using N+2 Voltage Transformation Modules (VTM)
 Redundant (N+2) Humidity Sensors
 Redundant (N+2) Altitude Sensors
 Unified Resource Manager for zBX
113
Improving Reliability
 Power & Thermal Optimization and Management
 Static Power Save Mode under z/OS control
 Smart blower management by sensing altitude and humidity
 Enhanced evaporator design to minimize temperature variations
 MCM cooling with N+1 design feature
 MCM backup cooling with Heat Exchanger
 Available air to water heat exchanger for customer water cooling
Concurrent Maintenance and Upgrades
– Duplex Units
• Power Supplies,
– Concurrent Microcode (Firmware) updates
– Hot Pluggable I/O
– PU Conversion
– Permanent and Temporary Capacity Upgrades
• Capacity Upgrade on Demand (CUoD)
• Customer Initiated Upgrade (CIU)
• On/Off Capacity on Demand (On/Off CoD)
– Capacity BackUp (CBU)
– Flexible & Plan Ahead Memory Options
114
57
z196 RAS Design of
……..Fully Redundant I/O Subsystem – of existing IO cage and drawers
processor
Fully Redundant I/O Design
Failover
I/O Hub
I/O Hub
Failover
I/O Mux
I/O Mux
I/O Mux
I/O Mux
I/O
Switch
I/O
Switch
Network
Switch
Network
Switch
Control
Unit
Control
Unit
End
User
End
User
ISC Links
ISC Links
Crypto Accelerator
Crypro Accelerator
Network adapter.
Network adapter.
I/O adapter.
I/O adapter.
Alternate Path


















SAP / CP sparing
SAP Reassignment
I/O Reset & Failover
I/O Mux Reset / Failover
Redundant I/O Adapter
Redundant I/O interconnect
Redundant Network Adapters
Redundant ISC links
Redundant Crypto processors
I/O Switched Fabric
Network Switched/Router Fabric
High Availability Plugging Rules
I/O and coupling fanout
rebalancing on CBA
Channel Initiated Retry
High Data Integrity Infrastructure
I/O Alternate Path
Network Alternate Path
Virtualization Technology
115
Create a redundant I/O configuration
LPARn
LPAR2
LPAR1
LPARn
LPAR2
LPAR1
CSS /
CHPID
Director
(Switch)
DASD CU
DASD CU
....
116
58
BACKUP
Slides
117
Did You Know...
118
59
Did You Know...
119
Did You Know...
120
60
Did You Know...
121
Quick Quiz: Which is the Better Vehicle?
VS.
Maserati MC12
Peterbilt Semi
The Race - ¼ Mile Dragstrip
122
61
Quick Quiz: Which is the Better Vehicle?
VS.
100 Maserati MC12
Peterbilt Semi
The Race - ¼ Mile Dragstrip
Carrying 10 tons of crates
123
Is this Better?
VS.
Peterbilt Semi
10 Ford F-450 1 ton Pickups
The Race - ¼ Mile Dragstrip
Carrying 10 tons of crates
124
62
Mainframe History - Myth vs. Truth
 http://www-01.ibm.com/software/info/getztruth/index.jsp
 ftp://public.dhe.ibm.com/s390/misc/bookoffer/download/360revolution_040704.pdf
 http://www.vm.ibm.com/devpages/jelliott/pdfs/zhistory.pdf
 ftp://ftp.software.ibm.com/s390/audio/pdfs/zSeriesMainframeInnovations.pdf
 http://www.ca.com/us/bigiron.aspx
125
Academic Initiative: Success Story
IBM Training Center for Mainframe opens at VIT, Vellore, India
– Students in Indian universities and colleges are generally taught about personal
computers and small server technology. But mainframes run businesses, and students
need exposure to this critical technology before they enter the workforce to maximize
their effectiveness. The need was recognized by Chancellor G. Viswanathan of the
Vellore Institute of Technology (VIT) in India – as well as by an IBM team looking for
engineering institutes.
• The opportunity opened in September 2010 for IBM to establish a partnership with
VIT, a top-tier academic institute, which was ready to commit to nurturing and
growing a System z ecosystem. Developed as
part of the IBM Academic Initiative System z Program, this unique
initiative builds partnerships with colleges and universities worldwide to
add IBM enterprise systems education to curricula and put the mainframe back in
computer science programs.
– The program kicked off with several training sessions that the India
System z ISV team conducted at the VIT campus to educate professors and students on
z/OS concepts. IBM helped the university explore enterprise system solutions as they
built a long-term partnership with professors and the student community. In August, the
“IBM Training Center for Mainframes” was officially launched at VIT. This is the second
Training Center for Mainframe of its type in the world, and the first one in Asia. It has 60
dedicated high-end computers with 24/7 connectivity to the centralized System z in
Dallas, Texas.
– VIT has added a course on “Introduction to Mainframe Computing” and offered it as an
elective in its Master of Computer Applications curriculum.
– Chancellor Viswanathan has referred to IBM as a big role model and ensured that VIT
will make use of IBM‟s presence to foster innovation.
“India has the big advantage of producing the largest number of IT professionals in the
world. The VIT will try to emerge as one of IBM‟s best partners,” he said.
126
63
Master the Mainframe Contest
 No experience with mainframes is necessary. In fact, the contest is designed for students
with little or no mainframe experience, increasing with difficulty as the contest progresses.
Students just need to bring drive and competitive spirit and be ready to compete!
 Experience!
Today's mainframes are growing in popularity and require a new generation of mainframe
experts. This contest is designed to equip you with basic skills to make you more
competitive for jobs in the enterprise computing industry. Participation in the Master the
Mainframe contest could give you the edge you need.
127
References
 Introduction to the New Mainframe: Large-Scale Commercial Computing, SG24-7175-00
 IBM Mainframe Strengths and Values, SG24-7333-01
 Introduction to the New Mainframe: z/OS Basics, SG24-6366-01
 ABCs of z/OS System Programming Volume 1, SG24-6981-01
 ABCs of z/OS System Programming Volume 2, SG24-6982-02
 ABCs of z/OS System Programming Volume 3, SG24-6983-03
 ABCs of z/OS System Programming Volume 4, SG24-6984-00
 ABCs of z/OS System Programming Volume 5, SG24-6985-01
 ABCs of z/OS System Programming Volume 6, SG24-6986-00
 ABCs of z/OS System Programming Volume 7, SG24-6987-01
 ABCs of z/OS System Programming Volume 8, SG24-6988-00
 ABCs of z/OS System Programming Volume 9, SG24-6989-04
 ABCs of z/OS System Programming Volume 9, SG24-6989-05
 ABCs of z/OS System Programming Volume 10, SG24-6990-03
 ABCs of z/OS System Programming Volume 11, SG24-6327-01
 ABCs of z/OS System Programming Volume 12, SG24-7621-00
 ABCs of z/OS System Programming Volume 13, SG24-7717-00
 IBM zEnterprise 196 Technical Guide, SG24-7833-00
 IBM zEnterprise System Technical Introduction, SG24-7832-00
 IBM zEnterprise 114 Technical Guide, SG24-7954-00
 IBM System z Connectivity Handbook, SG24-5444-12
 z/Architecture Principles of Operation, SA22-7832-08
 z/Architecture Reference Summary, SA22-7871-06
128
64