PAR FORM PAR Status: 06/11/02 Revision of Revision PAR PAR Approval Date: 06/13/2002 PAR Signature Page on File: Yes Review of Standards Development Process: 1. Assigned Project Number: C37.24 2. Sponsor Date of Request: 04/08/2002 3. Type of Document: No Guide for 4. Title of Document: Draft: Guide for Evaluating the Effect of Solar Radiation on Outdoor Metal-Enclosed Switchgear 5. Life Cycle: Full Use 6. Type of Project: 6a. Is this an update to an existing PAR? Yes If YES: Indicated PAR number/approval date: C37.24-09/16/1999 If YES: Is this project in ballot now? No 6b. The project is a: Revision of Std.C37.24-1986 7. Contact Information of Working Group: Name of Working Group (WG): C37.24 Name of Working Group Chair: Dave Gohil Telephone: 573-642-6811x34 Email: FAX: 573-642-6844 dgohil@poweraisle.com 8. Contact Information of Official Reporter (If different than Working Group Chair ) Name of Official Reporter: (if different than WG Contact) Telephone: FAX: Email: 9. Contact Information of Sponsoring Society or Standards Coordinating Committee Name of Sponsoring Society and Committee: Power Engineering Society/Switchgear Name of Sponsoring Committee Chair: Roy W Alexander Telephone: 610-774-4684 Email: FAX: 610-774-6388 rwalexander@pplweb.com Name of Liaison Rep.(If different than Sponsor Chair): M. Dean Sigmon Telephone: 843-665-4144x4707 Email: FAX: 843-667-5109 michael.d.sigmon@us.abb.com 10. The type of ballot is: Individual Sponsor Ballot Expected Date of Submission for Initial Sponsor Ballot: 05/05/2002 11. Fill in Projected Completion Date for Submittal to RevCom: 9/16/2003 Explanation for Revised PAR that completion date is being extended past the original four-year life of the PAR: This is a revised PAR but the completion date is not required to be extended. Only reason for submitting a revised PAR is to match 'Purpose' of PC37.24/D6 to PAR., First Draft:1999-05-24, Active People:6, Meeting:2, Frequence of Draft Circulated: 2, Stability of Draft: 100%, Num of Rev: 6, Project Status: Draft is complete and ready to ballot. Invitation to ballot PC37.24/D6 has already been sent (on 04-04-2002) by IEEE. 12. Scope of Proposed Project: The general information in this Guide is intended to assist in evaluating the effect of solar radiation on outdoor metal-enclosed switchgear and is applicable to outdoor metal-enclosed power switchgear, control switchboards and metal-enclosed bus. Specific data are given in current temperature relationship and tabulation form for outdoor metal-enclosed low-voltage power circuit breaker switchgear, outdoor metal-clad switchgear and outdoor metal-enclosed interrupter switchgear. 13. Purpose of Proposed Project: Switchgear will perform satisfactorily and have a reasonable life when operated within the temperature limits estab-lished in ANSI/IEEE C37.20.1, C37.20.2, C37.20.3, C37.21 and C37.23. These standards specify the temperature rise limits above a standard (maximum) ambient temperature of 40 •C. This is satisfactory for indoor applications where the temperature rise is due entirely to heat release (internal losses). In outdoor applications, the limiting tem-peratures result from the net effect of internal losses and external influences, principally the sun, wind and local am-bient temperatures. All of these must be considered in determining the current-carrying capacity of outdoor metal-enclosed switchgear. The magnitude of these factors will vary geographically and from season to season. The time relationship of maxi-mum circuit loads with respect to maximum ambient temperature is important. It is not practical to design switch-gear on the basis that all adverse factors reach their maxima coincident with maximum loads. If this does not occur, full current ratings may be realized. Recommendations will be made to point out the cumulative effect of these various influences. 14. Intellectual Property Sponsor has reviewed the IEEE patent policy with the working group? Yes Sponsor is aware of copyrights relevant to this project? Yes Sponsor is aware of trademarks relevant to this project? Yes Sponsor is aware of possible registration of objects or numbers due to this project? Yes 15. Are you aware of other standards or projects with a similar scope? No Similar Scope Project Information: 16. Is there potential for this standard (in part or in whole) to be submitted to an international organization for review/ adoption? Do Not Know If yes, please answer the following question: Which International Organization/Committee? International Contact Information: 17. Will this project focus on Health, Safety or Environmental Issues? No 18. Additional Explanatory Notes:(Item Number and Explanation) Item 6 (Reason for revising PAR): To match the 'Purpose' stated in PC37.24/D6 to PAR. This unintentional inconsistency has been communicated to Jodi Haasz. Signature page is transmitted to Jodi Haasz by fax (208-460-5300).