PAR FORM PAR Status: 09/16/02 Revision of Revision PAR PAR Approval Date: 09/12/2002 PAR Signature Page on File: Yes Review of Standards Development Process: 1. Assigned Project Number: C37.60 2. Sponsor Date of Request: 08/02/2002 3. Type of Document: No Standard for 4. Title of Document: Draft: Standard Requirements for Overhead, Pad Mounted, Dry Vault, and Submersible Automatic Circuit Reclosers and Fault Interrupters for alternating current systems up to 38 kV 5. Life Cycle: Full Use 6. Type of Project: 6a. Is this an update to an existing PAR? Yes If YES: Indicated PAR number/approval date: C37.60-03/21/1996 If YES: Is this project in ballot now? Yes 6b. The project is a: Revision of Std.C37.60-1981 7. Contact Information of Working Group: Name of Working Group (WG): Recloser Standards C37.60 and C37.61 Name of Working Group Chair: David Stone Telephone: 414-768-8247 Email: FAX: 414-768-8236 dstone@cooperpower.com 8. Contact Information of Official Reporter (If different than Working Group Chair ) Name of Official Reporter: (if different than WG Contact) Telephone: FAX: Email: 9. Contact Information of Sponsoring Society or Standards Coordinating Committee Name of Sponsoring Society and Committee: Power Engineering Society/Switchgear Name of Sponsoring Committee Chair: Roy W Alexander Telephone: 610-774-4684 Email: FAX: 610-774-6388 rwalexander@pplweb.com Name of Liaison Rep.(If different than Sponsor Chair): M. Dean Sigmon Telephone: 843-665-4144x4707 Email: FAX: 843-667-5109 michael.d.sigmon@us.abb.com 10. The type of ballot is: Individual Sponsor Ballot Expected Date of Submission for Initial Sponsor Ballot: 09/01/2002 11. Fill in Projected Completion Date for Submittal to RevCom: 10/1/2002 Explanation for Revised PAR that completion date is being extended past the original four-year life of the PAR: 12. Scope of Proposed Project: This Standard applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters for rated maximum voltages above 1000 V and up to 38 kV. The following is also included in section 1: In order to simplify this standard where possible, the term recloser/FI (reclosers/FIs) has been substituted for automatic circuit recloser or fault interrupter or both. NOTE--When reclosers are applied in substation, special considerations may apply. 13. Purpose of Proposed Project: The purpose of this project is to revise existing standard including, but not limited to: a) general update to bring the standard in line with current technology; b) update information on BIL, altitude correction, temperature rise; c) add information on other interrupting/insulating media (e.g. SF6); d) add transient recovery voltage requirements; e) add voltage ratings common to systems outside of North America 14. Intellectual Property Sponsor has reviewed the IEEE patent policy with the working group? Yes Sponsor is aware of copyrights relevant to this project? Yes Sponsor is aware of trademarks relevant to this project? Yes Sponsor is aware of possible registration of objects or numbers due to this project? Yes 15. Are you aware of other standards or projects with a similar scope? No Similar Scope Project Information: 16. Is there potential for this standard (in part or in whole) to be submitted to an international organization for review/ adoption? Yes If yes, please answer the following question: Which International Organization/Committee? IEC TC17A International Contact Information: Anne Bosma Phone: +46 240 782403 FAX: +46 240 782390 Email: anne.bosma@se.abb.com 17. Will this project focus on Health, Safety or Environmental Issues? No 18. Additional Explanatory Notes:(Item Number and Explanation) This is a request for a revison to the PAR. Title Change to add: ". . . for alternating current systems up to 38 kV". Scope Changed to read: "This Standard applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters for rated maximum voltages above 1000 V and up to 38 kV. Reason: This addresses one of the technical comments received in the 2nd ballot and is consistent with the scope of other standards in the Recloser and Other Distribution Equipment Subcommittee's charter. The 1981 revision to C37.60 did include one rating line each for 46 kV and 72 kV, however there are no manufacturers know to the WG that currently or ever the past had ratings above 38 kV The WG decided to drop these ratings from the standard.