selectronic® sensor-operated toilet flush valve, 1.28 gpf

advertisement
SELECTRONIC® SENSOR-OPERATED
TOILET FLUSH VALVE, 1.28 GPF
HARD-WIRED AC POWERED
MODEL NUMBER:
❑ 6067.121.002 Hard-Wired AC Powered:
Includes Class 2 UL certified universal hard-wired
AC transformer (electrical box by others).
❑ 6068.121.002 Multi-AC Powered:
Includes 10' extension cable and Y-connector.
One transformer can power up to 15 faucets and/
or flush valves in a daisy chain configuration
TRANSFORMER NOT INCLUDED.
OPERATING PRESSURE:
Overall Range: 20-125 psi**
Recommended: 25 psi (flowing)-80 psi (static)
** Water pressure over 80 psi is not recommended
for most plumbing fixtures.
GENERAL DESCRIPTION:
Exposed, sensor-operated Selectronic ® Toilet Flush Valve
for floor-mounted or wall-hung 1-1/2" top spud bowls,
1.28 gpf. Hard-Wired AC powered.
Inlet includes 1" sweat solder kit and angle stop with back
flow protection and vandal-resistant cap.
Outlet includes 1-1/2" high back pressure vacuum breaker
with spud coupling and flange.
FLOW REQUIREMENT:
25gpm (94.6 L/min.)
ACCESSORIES:
• Cast wall flanges: 1" (6065.810) & 1-1/2" (6065.815)
• Solid ring pipe supports: 2-1/2" C-E (6065.821) &
6" C-E (6065.861)
• Split ring pipe supports: 2-1/2" C-E (6065.822) &
6" C-E (6065.862)
PRODUCT FEATURES:
• Universal Input Voltage: 100-240 VAC, 50/60 Hz
• Optional Chrome Cover Plate: Only required if AC
transformer must be installed from the front
• Self-Cleaning Piston with integral wiper spring
significantly reduces clogging and maintenance
• Selectronic ® Proximity System with universal sensor
provides hygienic, "hands free" operation
• S
tate-of-the-Art Electronics prevent ghost flushing
• Dezincification Resistant semi-red brass alloy
• Fully Mechanical Manual Override Button can flush the
valve without power
• Fail-Safe: Valve automatically closes upon loss of power
or water pressure and does not need to be reset
• Adjustable Sanitary Flush cleans the fixture & maintains
the trap seal.
• Stadium Feature: Valve automatically switches to water
savings mode during periods of heavy usage
• Chemical Resistant EPDM Seals for extended life
• High Back Pressure Vacuum Breaker
• Adjustable Tailpiece
• Range can be adjusted manually or with optional
remote control
• No external volume adjustment.
• Can be installed left or right handed
TYPICAL WATER CLOSET INSTALLATION:
AFWALL™ TOILET SHOWN
FINISHED WALL
73mm
(2-7/8")
86mm
(3-3/8")
160mm
(6-1/4")
COVER &
ELECTRICAL
BOX
409mm
(16-1/8")
SUPPLY
DN 25mm
(1" I.P.S.)
-C-L-
293mm
(11-1/2")
108mm - 134mm
(4-1/4" - 5-1/4")
FINISHED
FLOOR
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 REQUIREMENTS FOR ACCESSIBLE AND
USABLE BUILDING FACILITIES-CHECK LOCAL CODES
RECOMMENDED SPECIFICATION:
Electronic, sensor activated toilet flush valve shall feature self-cleaning piston valve with integral wiper spring in refill orifice to prevent clogging. Powered by Class 2 UL certified hard-wired AC transformer with universal input voltage of 100 - 240 VAC, 50/60 HZ. Includes a fully
mechanical manual override that can flush the valve without power. Includes semi-red brass valve body and metal cover with chrome finish.
Includes angle stop with back-flow protection & vandal-resistant cap. Sweat solder kit and high back pressure vacuum breaker also included.
1.28 gpf / 4.8 Lpf flush valve shall be American Standard Model # 606_.121.002.
© 2014 AS America Inc.
L321
11/14
SELECTRONIC® SENSOR-OPERATED
TOILET FLUSH VALVE, 1.28 GPF
HARD-WIRED AC POWERED
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS
supplied cables, or cutting, splicing or modifying
any components will void the warranty.
LISTINGS:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant
Roughing-in Dimensions
180 ˚
160mm
(6-1/4")
72mm
(2-7/8")
MANUAL
OVERRIDE
BUTTON
51mm (2") HOLE
FOR CONDUIT
45 ˚
305mm
(12" MAX.)
FINISHED WALL
15˚
116mm
(4-5/8")
*CRITICAL
LEVEL
293mm
(11-1/2")
2-GANG ELECTRICAL
BOX BY OTHERS
160mm
(6-1/4")
86mm
(3-3/8")
DETECTION ZONE
400mm-800mm
(15-3/4" TO 31-1/2")
SUPPLY
DN 25mm
(1" I.P.S.)
-C-L-
108mm-134mm
(4-1/4" TO 5-1/4")
409mm
(16-1/8")
FOR 1-1/2" TOP
SPUD FIXTURES
57mm (2-1/4") 137mm (5-3/8")
TOP OF
FIXTURE
Right or Left Hand Installation
*Note: The Critical Line (-C-L-) on Vacuum Breaker
must typically be 6 " min. (152mm) above fixture.
Consult Codes for details.
© 2014 AS America Inc.
L322
11/14
Download