ALLBROOK® 1.0 GPF URINAL SYSTEM

advertisement
ALLBROOK® 1.0 GPF
URINAL SYSTEM
SELECTRONIC ® EXPOSED AC FLUSH VALVE
BARRIER FREE
ALLBROOK® 1.0 GPF URINAL SYSTEM
❏6541.615 1.0 gpf Exposed Top Spud Urinal &
Selectronic® Exposed AC Urinal Flush Valve
URINAL:
• Vitreous china
• High Efficiency: Operates in the range of
0.5 gpf to 1.0 gpf (1.9 Lpf/3.8 L/pf)
• Flushing rim
• Siphon jet flush action
• 3/4" inlet spud
• Outlet connection threaded 2" inside (NPTF)
• Meets ANSI flush requirements at 0.5 to 1.0 gpf
• Model 6550.001
SELECTRONIC® VALVE:
• Pressure Compensation feature ensures accurate
flush volume regardless of inlet water pressure
• Self-Cleaning Piston with integral wiper spring
significantly reduces clogging and maintenance
• Selectronic® Proximity System with universal sensor
provides hygienic, "hands free" operation
• State-of-the-Art Electronics prevent ghost flushing
• Dezincification Resistant semi-red brass alloy
• Fully Mechanical Manual Override Button can flush
the valve without power
• Fail-Safe: Valve automatically closes upon loss of power
or water pressure and does not need to be reset
• Adjustable Sanitary Flush cleans the fixture & maintains
the trap seal.
• Stadium Feature: Valve automatically switches to water
savings mode during periods of heavy usage
• Chemical Resistant EPDM Seals for extended life
• Adjustable Tailpiece for rough-in flexibility
• Can be installed left or right handed
• Includes Class 2 UL certified universal hard-wired
AC transformer
• Universal input voltage: 100 - 240 VAC, 50/60 Hz
• Optional cover plate only required for installation
from the front
• Model 6062.101
SEE REVERSE FOR ROUGHING-IN DIMENSIONS
Operating Pressure:
20 psi (flowing) - 80 psi (static)
Flow Requirement:
10gpm (37.9 L/min.)
Nominal Fixture Dimensions:
356 x 363 x 546mm (14" x 14-5/16" x 21-1/2")
Includes:
• 3/4" I.P.S. angle stop with back-flow
protection and vandal resistant cap
• 3/4" Sweat solder kit including cover tube
and wall flange
• 3/4" High back pressure vacuum breaker,
spud coupling and flange
MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 ACCESSIBLE AND USEABLE BUILDINGS AND
FACILITIES - CHECK LOCAL CODES.
When installed so top of rim is 432mm (17") from finished floor.
N7
© 2016 AS America Inc.
spec_6541.615 Allbrook 1.0gpf Rev. C 6/16
ALLBROOK® 1.0 GPF
URINAL SYSTEM
SELECTRONIC ® EXPOSED AC FLUSH VALVE
BARRIER FREE
FINISHED WALL
160mm
(6-1/4")
180˚
MANUAL
OVERRIDE
BUTTON
116mm
(4-5/8")
72mm
(2-7/8")
51mm (2") HOLE
FOR CONDUIT
45˚
305mm
(12 MAX.)
15˚
86mm
(3-3/8")
*CRITICAL
LEVEL
293mm
(11-1/2")
-C-L-C-L152mm
(6" MIN.)
2-GANG
ELECTRICAL
BOX BY OTHERS
DETECTION ZONE
400-800mm
(15-3/4 to 31-1/2")
86mm
(3-3/8")
SUPPLY
DN 20mm
(3/4" I.P.S.)
64mm
(2-1/2")
108-134mm
(4-1/4 to
5-1/4")
TOP OF
FIXTURE
409mm
(16-1/8")
HANGER
292mm
(11-1/2")
359mm
(14-1/8")
356mm
(14")
C/L
546mm
(21-1/2")
363mm
(14-5/16")
191mm
(7-1/2")
16mm
(5/8")
C/L OF
OUTLET
102mm
(4")
432mm
(17")
610mm
(24")
OPTIONAL
TO FINISHED
FLOOR
*Note: The Critical Line (-C-L-) on
Vacuum Breaker must typically be a
minimum of 6" (152mm) above fixture.
Consult Codes for details.
FINISHED
FLOOR
13mm
(1/2")
13mm
(1/2")
FINISHED WALL
2" N.P.T.
FEMALE
OUTLET
CONNECTION
GASKET
102mm
(4")
2" N.P.T.
INSIDE THREADS
DETAIL OF OUTLET CONNECTION
VALVE LEFT or RIGHT HAND INSTALLATION
Fixture Compliance Certifications Meets or Exceeds the Following Specifications:
• ASME A112.19.2-2008/CSA B45.1-08 for Vitreous China Fixtures
NOTES:
PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS.
IMPORTANT: Dimensions of fixtures are nominal and may vary within
the range of tolerances established by ANSI Standard A112.19.2. These
measurements are subject to change or cancellation. No responsibility is
assumed for use of superseded or voided pages.
Valve Listings:
• ASSE 1037
• ANSI/ASME A112.19.2
• ADA Compliant