ALLBROOK® 1.0 GPF URINAL SYSTEM SELECTRONIC ® EXPOSED AC FLUSH VALVE BARRIER FREE ALLBROOK® 1.0 GPF URINAL SYSTEM ❏6541.615 1.0 gpf Exposed Top Spud Urinal & Selectronic® Exposed AC Urinal Flush Valve URINAL: • Vitreous china • High Efficiency: Operates in the range of 0.5 gpf to 1.0 gpf (1.9 Lpf/3.8 L/pf) • Flushing rim • Siphon jet flush action • 3/4" inlet spud • Outlet connection threaded 2" inside (NPTF) • Meets ANSI flush requirements at 0.5 to 1.0 gpf • Model 6550.001 SELECTRONIC® VALVE: • Pressure Compensation feature ensures accurate flush volume regardless of inlet water pressure • Self-Cleaning Piston with integral wiper spring significantly reduces clogging and maintenance • Selectronic® Proximity System with universal sensor provides hygienic, "hands free" operation • State-of-the-Art Electronics prevent ghost flushing • Dezincification Resistant semi-red brass alloy • Fully Mechanical Manual Override Button can flush the valve without power • Fail-Safe: Valve automatically closes upon loss of power or water pressure and does not need to be reset • Adjustable Sanitary Flush cleans the fixture & maintains the trap seal. • Stadium Feature: Valve automatically switches to water savings mode during periods of heavy usage • Chemical Resistant EPDM Seals for extended life • Adjustable Tailpiece for rough-in flexibility • Can be installed left or right handed • Includes Class 2 UL certified universal hard-wired AC transformer • Universal input voltage: 100 - 240 VAC, 50/60 Hz • Optional cover plate only required for installation from the front • Model 6062.101 SEE REVERSE FOR ROUGHING-IN DIMENSIONS Operating Pressure: 20 psi (flowing) - 80 psi (static) Flow Requirement: 10gpm (37.9 L/min.) Nominal Fixture Dimensions: 356 x 363 x 546mm (14" x 14-5/16" x 21-1/2") Includes: • 3/4" I.P.S. angle stop with back-flow protection and vandal resistant cap • 3/4" Sweat solder kit including cover tube and wall flange • 3/4" High back pressure vacuum breaker, spud coupling and flange MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES AND ANSI A117.1 ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES - CHECK LOCAL CODES. When installed so top of rim is 432mm (17") from finished floor. N7 © 2016 AS America Inc. spec_6541.615 Allbrook 1.0gpf Rev. C 6/16 ALLBROOK® 1.0 GPF URINAL SYSTEM SELECTRONIC ® EXPOSED AC FLUSH VALVE BARRIER FREE FINISHED WALL 160mm (6-1/4") 180˚ MANUAL OVERRIDE BUTTON 116mm (4-5/8") 72mm (2-7/8") 51mm (2") HOLE FOR CONDUIT 45˚ 305mm (12 MAX.) 15˚ 86mm (3-3/8") *CRITICAL LEVEL 293mm (11-1/2") -C-L-C-L152mm (6" MIN.) 2-GANG ELECTRICAL BOX BY OTHERS DETECTION ZONE 400-800mm (15-3/4 to 31-1/2") 86mm (3-3/8") SUPPLY DN 20mm (3/4" I.P.S.) 64mm (2-1/2") 108-134mm (4-1/4 to 5-1/4") TOP OF FIXTURE 409mm (16-1/8") HANGER 292mm (11-1/2") 359mm (14-1/8") 356mm (14") C/L 546mm (21-1/2") 363mm (14-5/16") 191mm (7-1/2") 16mm (5/8") C/L OF OUTLET 102mm (4") 432mm (17") 610mm (24") OPTIONAL TO FINISHED FLOOR *Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be a minimum of 6" (152mm) above fixture. Consult Codes for details. FINISHED FLOOR 13mm (1/2") 13mm (1/2") FINISHED WALL 2" N.P.T. FEMALE OUTLET CONNECTION GASKET 102mm (4") 2" N.P.T. INSIDE THREADS DETAIL OF OUTLET CONNECTION VALVE LEFT or RIGHT HAND INSTALLATION Fixture Compliance Certifications Meets or Exceeds the Following Specifications: • ASME A112.19.2-2008/CSA B45.1-08 for Vitreous China Fixtures NOTES: PROVIDE SUITABLE REINFORCEMENT FOR ALL WALL SUPPORTS. IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard A112.19.2. These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided pages. Valve Listings: • ASSE 1037 • ANSI/ASME A112.19.2 • ADA Compliant N8 © 2016 AS America Inc. spec_6541.615 Allbrook 1.0gpf Rev. C 6/16