Kurtzon Lighting

advertisement
Medical Lighting Brochure
Rush University: Illinois Medical District, Chicago, IL
Quality Since 1898
1
Kurtzon
Kurtzon Lighting
Lighting
Kurtzon
Kurtzon Lighting
Lighting
MADE IN USA
www.Kurtzon.com
www.Kurtzon.com
Table Of Contents
Performance Chart
3
Applications
4
Superior Quality Outstanding Results
5
Trends in Healthcare Design
6
Corrosion Resistance, EMI, Custom Mounting
7
Trends in Surgical Suite Design
8-9
New Healthcare Projects
8
Custom Flange Layout Guide
10-11
4 Threats To Controlling Healthcare Associated Infections
12
Exam & Patient Room Luminaires
13
Darkroom Safelights
14
Waiting Area/ Lobby
15
Cafeteria
16
MRI Rooms
17
Catalog Pages
ML-EF-1X4
ML-EF-2X2, 2X4
ML-EG-1X4
ML-EG-2X2, 2X4
ML-F-1x4
ML-F-2x2, 2X4
ML-G-1x4
ML-G-2x2, 2X4
ML-OF-1x4
ML-OF-2X2, 2X4
ML-OG-1X4
ML-OG-2X2, 2X4
ML-COR
ML-MRV-LED
ML-MRV
ML-MRH
ML-G/PR
DS-F/G
ML-MRIOF 2X2, 2X4
ML-AG-1X4, 2X2, 2X4
RD-F/G-2FT, 3FT, 4FT
WEB ONLY
WEB ONLY
WEB ONLY
PAGE 18
WEB ONLY
PAGE 19
WEB ONLY
PAGE 20
WEB ONLY
PAGE 21
WEB ONLY
WEB ONLY
PAGE 22
PAGE 23
WEB ONLY
WEB ONLY
PAGE 24-25
WEB ONLY
PAGE 26-27
PAGE 28
PAGE 29
In an effort to conserve paper and go green, Kurtzon Lighting has limited the number of catalog pages
printed in this brochure. All of our pages for all of our different sections are available on our website.
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
2
Combating The Inferior Products
It is no secret that lesser quality products have permeated into the marketplace. In order to combat this we
have developed a Product Selector Chart
This is a guide to help you understand if the products you are viewing that may be marketed as a medical
troffer meet these specifcations for our most BASIC medical troffer, the ML-EF/EG
3
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
Applications:
Applications
Emergency Room
X-Ray Darkroom
Surgical Suites
Patient Rooms
Nurses Station
Psych Rooms
MRI Suites
Laboratories
Forensics
Morgue
Most Kurtzon products are UL listed for wet location & can withstand 85 PSI.
Some can be rated to 1700 PSI.
Other Applications:
Lobby
Kitchen
Stairwell
Corridors
Cafeteria
Rehab Pools
Parking Structure
Shower / Locker rooms
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
4
Superior Quality, Outstanding Results
It is beyond a highly engineered, precisely constructed
lighting fixture. It is an established practice of going beyond
what is required to create the best performing, most resilient
supplemental surgical lighting in the industry. Kurtzon was the
first lighting company to introduce stainless steel lighting
fixtures into surgical rooms. At the time this was seen as
unnecessary; Morris Kurtzon, our company’s founder, insisted
that stainless steel was the right choice to ensure a sanitary
medical environment. It is this kind of visionary expertise that
continues to push Kurtzon to the forefront of
high end medical technology.
5
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
Trends In Healthcare Design
WIth the Healthcare Reform Bill signed into law, hospital administrators are increasingly being more critical of budgets and equipment that have an impact on the budget. To healthcare designers and their clients, this does not mean returning to the impersonal rooms of
the past, sometimes holding more than three patients, but rather using fixtures with a high
longevity. We are all aware that going green is a lasting trend, and it is well documented
that Kurtzon’s fixtures often times outlast the hospitals they are placed in.
Healthcare facilities are increasingly becoming more integrated with cultural centers and
educational
institutions, leading to advancements in research and development, new processes and
procedures and a more integrated setting where learning and expertise occur in the same
building.
Over the last few years, evidence based research and numerous publications from psychological institutions have indicated that design features focusing on mood, well-being, color
and illumination. The idea is to make the healthcare facility seem more like a presonalized
room, replete with the usual accoutrements of a residential room.
New buildings being designed are required to account for their environmental impact, and
such decisions are made in the early planning stages. Specifiers have been selecting lighting
products that use less energy and do not require additional maintenance.
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
6
Corrosion Resistance, No Emissions, Custom Mounting
LENS - Two piece acrylic lens system with an external clear lens for easy cleaning and a linear prismatic acrylic
lens internal for light control. RFI shielded with a .375” metallic conductive grid that complies with radiated
emissions (RE101) of Military Standard 461E. RFI (Radio Frequency Interference), which is also known as EMI
(Electromagnetic Interference) is any electromagnetic radiation or disturbance which is emitted from an
electrical circuit or electronic component that interrupts or interferes with the operation of other electronic
components, or electrical circuits. RFI or EMI may be introduced intentionally as in the case of electronic
warfare, or unintentionally from an electronic or electrical device or system. EMI may also be created as a
result of a nuclear explosion. EMI / RFI shielding should be an integral consideration to electronic device or
electronics system design. Good RFI / EMI design techniques include, mechanical or electromagnetic shielding,
careful circuit filtering design, adequate circuit ground design, as well as, attenuation to the bonding of the
ground points
DOOR FRAME - Aluminum, cold-rolled steel (CRS) or stainless steel door frames come in channel inset, one
piece inset or overlapping styles. 20-gauge CRS or stainless steel channel door frame hinged to housing with
continuous stainless steel piano hinge. Secured with 2 captive stainless steel fasteners. See Options for 85 PSI
rating (HD-85). The overlapping door frame is usually reserved for clean room applications, however, in certain medical applications where a high pressure washdown is required, our fixtures can withstand a 1700 PSI
hose down, equivalant to IP66.
HOUSING - Aluminum, cold-rolled steel (CRS) or stainless steel housings are completley hole free and seam
welded. We even take the cleanliness one step further by reinforcing the seams with silicone sealant on the
OF/OG series.
CUSTOM MOUNTING - The ML-F’s continuous row mounting allows the fixtures to be placed end- to-end
and end-to-side in nearly any continuous row or rectangle.
The series uses twelve (12) different fixtures to
provide the flexibility to create a neat and clean installation without overlapping flanges or penetrations in the
plenum seal. This arrangement allows direct through wiring of all fixtures, a sealed plenum space and an accommodating fixture arrangement.
ML-OG
7
Kurtzon
Kurtzon Lighting
Lighting
ML-OF (Custom Flange)
ML-S (Custom Graphic)
www.Kurtzon.com
Trends In Surgical Suite Design
Surgical suite design has developed significantly over the past 10 years and will continue to change over the
next decade. Surgical suites used to be on average 400 feet but have now increased in size to 600 feet to accmomodate larger equipment, more staff and a diverse range of specialists.
The evolution of using the smaller group of operating rooms over the larger groups of them in the past.
Now we see a more specialized approach to grouping specific surgical specialties together. With this trend we
have also seen an increase in the utilization of minimally invasive surgical techniques. This increase has had
a double effect; in the short run, it has drawn the need for larger operating rooms, but as technology evolves,
we will see a decrease in the size of these rooms, based on new robotic technology and remote equipment
that does not require as much human interaction. Minimally invasive surgery (MIS) is an efficient, low-risk
surgical procedure. It is a safe, feasible, and patient-friendly method of performing an operation. Minimally
invasive techniques satisfy patients’ desire for a swift recovery and shorten the hospitalization period. As
a result, these procedures are being employed across various specialties. These procedures are performed
through small incisions, where endoscopes are plugged-in to operate from within a body cavity and offer numerous advantages over the conventional invasive surgeries. The major benefits of minimally invasive surgical
procedures are: superior cosmetic result; reduced post-operative pain and faster recovery rates. Over the last
decade and a half, it is apparent that minimally invasive surgery is gaining ground rapidly
The development of special high-technology ORs, including intra-operative MRI rooms. MRI rooms require special fixtures and electrical components. Kurtzon offers fluorescent and LED lighting options for these
rooms. Fluorescent lamps interrupt the MRI read, so these lamps must be switched off while the MRI machine
is in use. LED’s can be used while the MRI machine is on, and with the push for green technology greater than
ever, it is a nice alternative in specific environments where maitnenance can be costly.
Operating room size
It is now uncommon for a surgical suite to be programmed with operating rooms of less than 600 square feet,
unless the focus of the unit is purely outpatient procedures. Even in outpatient centers with increased use of
MIS techniques, the need for larger ORs approaching 600 square feet is still present. Certainly the equipment
is the same, but in an outpatient setting, the cases are typically less complicated and are more predictable
and require smaller surgical teams. This often feeds into decisions to allow for slightly smaller ORs. In addition to the perception that outpatient facilities can be designed with smaller ORs, budget constraints are often
involved in the decision to limit the size of outpatient ORs. Nonetheless, most outpatient suites are still being
designed with ORs of over 500 square feet.
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
8
Healthcare
The efforts to create affordable healthcare for all is close to becoming a reality. The need for sanitary medical
environments will rise in conjunction with this increase in additional healthcare patients. To keep this in perspective, Kurtzon offers three different types of surgical troffers. EF-EG series Intended for the basic suites.
F-G Series This series has the many exclusive features found in suite fixtures. It is the only supplemental surgical suite luminaire to be offered with continuous rectangles. Intended for the areas where the highest light
levels need to be met, this feature moves fixtures closer to the table than any other. The OF and OG Series,
the O stands for optimized. This fixture has the widest array of features and is ready for the highest standards
applied to the surgical arena. Cleanroom ratings and NSF listed gaskets combine with anti-microbial finishes
and smooth surfaces for the cleanest suite solution. Our OF-OG series carry a cleanroom listing to ensure the
highest level of particulate protection. The decision to place a cleanroom rating on a medical troffer is one that
is often copied, but was initiated by Kurtzon Lighting given our extensive track record of creating lighting for
cleanroom environments.
Designers should apply the same principles for designing healing environments in a small rural area that they
do to a large urban one. Interiors need to communicate to potential staff, patients and the community the
hospital offers quality care.
This was the case when the Aurora Medical Center in Summit, WI was designed. Kurtzon’s ML-EF/EG fixtures
were selected for this project which Medical Construction Design magazine called “a resort like environmentemphasizing warm tones, curved walls and furniture with an abundance of natural light.”
9
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
Med Lock Series
ML-OF Operating Room Planning and Layout Guide
ML08
1. Layout
This guide is provided in order to help our users plan proper
installation of the complete Surgical lighting system.
The electrical plans contain information required to determine the configuration and quantity of each system component. Please provide the plan or complete this information
sheet and return it to the Kurtzon Customer Service Department.
There are three pieces of information needed before production of your order.
L
UA
Right End
Center
Left End
Right End
Center
Right End
Right End
Right End
Center
Center
Left End
Left End
Right End
Right End
Individual
Kurtzon Lighting
Lighting
10 Kurtzon
Center
Center
Rectangular
Open Corner
Left End
Left End
225 FC
Right End
Left End
Left End
Individual
Left End
I VID
IND
ML-OF Series fixtures are designed to join together without
overlapping flanges and seams. For example; the end fixtures are flanged on one end and two sides; center fixtures
are flanged on two sides. The complete housing is hole free,
silicone sealed and mates with adjoining housings using a
multi-point fastening and gasket system. This method creates
a sealed plenum.
The layouts below are the most common found within surgical suites. Please indicate which layout is used within your
plans. If a different design is required or none at all, please
specify your layout by sending us ceiling plan drawings or
sketches of your requirements. To assist you in your planning
we provide cad drawings from our website. This allows the
user to assemble nearly any layout selecting from eight different flange arrangements.
200 FC
245 FC
Rectangular
Closed Corner
www.Kurtzon.com
Two Rows
Med Lock
ML-OF Operating Room Planning and Layout Guide
ML08
2. Electrical
The electrical plans will indicate the number and configuration
of circuits controlling the fixture. A RFI filter is required per
switched circuit to comply with Mil Std. 461e. Please address
the following:
A. The number of switched circuits per fixture.
B. Emergency Lighting
Maintaining safe lighting levels in the surgical suite during a
power outage is possible using a self contained battery powered
emergency lighting ballast. Emergency lighting ballasts are
available in two general types. Standard NFPA 101 egress
lighting type and generator backup type. The two differ in the
amount of light generated and running time. The generator
backup type can drive up to three lamps at nearly full output
for a short duration, usually less than five minutes. Egress
lighting types will drive one or two lamps at a greatly reduced
output for 90 minutes. Please advise the type of emergency
lighting required for your project.
Right End
The standard fixture is provided with one switched circuit and
therefore one RFI. Additional switched circuits are specified
by the appropriate option suffix additions to the catalog number such as; 2/CIR or 3/CIR. Keep in mind; there is a physical limit to the number of ballasts RFI filters and emergency
lighting ballasts a fixture can contain. Our 2x4 fixture allows
up to four circuits or 3 circuits and one high lumen emergency
lighting ballast without modifications. Consult factory for
arrangements in excess of this. The smaller 2x2 fixture can
accommodate up to two circuits and a high lumen emergency
lighting ballast.
FA
Arrow indicates maximum
candlepower direction or aim.
(see label in fixture)
CL
FA1
Center
Ceiling cutout
W1
Left End
L1
FA
Cw
F
W2
3. Ceiling Cutout
This series is intended for recessed installation in a plaster or
drywall (GWB) ceiling system. The sizing of the ceiling finished
opening or "cutout" is important to a successful installation. We
provide detailed drawings showing the ceiling cutout size with
each order. Also available are cad drawings showing examples
and templates in 2D and 3D on our website. If you still need
to calculate your own finished ceiling openings please consider
the following. The ceiling cutout is always spaced 0.50 inches
from the housing body. This gives proper spacing and tolerance
to create a cutout and seal the plenum. Cutouts are calculated
using the following formulas.
L2
c
Dimensions (inches)
2x2
2x4
L1
Housing body (L) (along lamps)
24.0
48.0
W1
Housing body (W) (across lamps)
23.5
23.5
L2
Housing with two flanges (L) O.A.
25.5
49.5
W2
Housing with two flanges (W) O.A.
25.0
25.0
F
Flange extension from body
CL /CW
Individual Cutout (L1 +.5") x (W1 +.5")
0.75
24.5x24
0.75
48.5x24
Row Cutout Formulas:
CL = (L1 x Qty in Row) +1"
CW = W1 +1"
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
11
When thinking of lighting a hospital environment, much thought and care is put
into selecting the lighting products. Kurtzon has over 60 years experience in
lighting clean rooms that is unmatched in the healthcare sector. The operating
room, the most critical of medical areas, must have electrical components that
meet Military Standard 461E or F. Our Med Lock line surpasses this standard.
The Centers for Disease Control and Prevention (CDC) estimates that 5-10% of
hospitalized patients develop a healthcare associated infection (HAI),
corresponding to approximatley 2 million infections associated with nearly
100,000 deaths each year in US hospitals. According to CDC, HAI’s are one of
the top 10 causes of death in the US.
4 threats to address in controlling healthcare associated infections
1. Leakage of contaminants already present in the room
2. Leakage into the operatin room and/or fixtures from the celing plenum
3. Cleanability of the fixtures
4. Electromagnetic interference with hospital equipment
Kurtzon Lighting
Lighting
12 Kurtzon
www.Kurtzon.com
Exam & Patient Room Luminaires
The ML-G/PR - 2 FUNCTION PATIENT EXAM LIGHT
Lens With Internal Prisms For Cleanability
Up to 100 FC Exam Illumination
Hole Free Sealed Enclosure
Designed for T5 Technology
30 FC Ambient Illumination
Two Function Performance
For 1 & 1.5 inch T-bar Grid
Architectural Appearance
Shielded Ambient Lamp
Low Glare Lens System
IBEW Union Made
Electronic Dimming Ballast
Anti Microbial Finish
RFI Filtering
Fusing
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
13
Darkroom Safelights
The DS-F/G - LED Luminaires for Recessed & Surface Installation
Surface door hinged to housing with continuous stainless steel piano hinge
Recessed door hinged to housing with stainless steel cables
Secured with flush mounted captive stainless steel fasteners
20-gauge 4B satin polished stainless steel door frame
Door frame neoprene gasketed to housing
Integral light trap contains stray light
UL and CUL Listed for Wet Location
IBEW Label
Plaster Frame Kit
LED Options:
555 Green No. 3, 7,
660 Red No. 1, 1A, 2
Kurtzon Lighting
Lighting
14 Kurtzon
www.Kurtzon.com
Waiting Area / Lobby
Recessed or Surface Round Domes in 2FT, 3FT & 4FT
Our Round Dome series is the most dynamic, lowest profile and longest lasting product
in the lighting industry. Often imitated, never duplicated, this fixture has withstood the
test of time, finding a home in many of the top hospitals across the world.
Shown with graphic panel lens option
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
15
Cafeteria
Our lighting solutions for food zones are unparalleled in the industry. We have provided
NSF ® listed and marked lighting fixtures for the most stringent food requirement zones.
Kurtzon Lighting
Lighting
16 Kurtzon
www.Kurtzon.com
MRI Rooms
The recent expansion of Magnetic Imaging Technology into critical care spaces
created a demand for suitable lighting products. Kurtzon scientists and engineers
worked on developing improved products which could be used without danger or
risk to the occupants of the MRI spaces. Recently, Kurtzon was the first
manufacturer that introduced LED technology into MRI rooms, resulting in
additional benefits. The MRI space has been expanded into other life-support
areas, and the company has been working on new products to meet these
requirements (page 26-27). Users can be confident that this 112 year old company
will continue to lead the industry in these key areas.
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
17
Med Lock Series
2x2 and 2x4 Recessed 1" & 1.5" T-Bar Grid Luminaires for Basic Surgical Suites
Specifications:
ML03
Project:
Housing: One piece seam welded 20-gauge CRS, stainless steel or aluminium
construction. All seams of hole-free housing silicone sealed.
Fixture Type:
Door Frame: 20-gauge CRS or stainless steel channel door frame hinged to housing
with two stainless steel cables. Secured by captive stainless steel screws. See Options for
85 PSI rating (HD-85).
Cross Section
Gaskets: Neoprene, 100% pure, closed cell located at interface of door to housing and
door to lens. See Option “GG” for SealPro™ NSF Listed closed cell gasketing.
Reflector: Full reflector panel designed to enhance asymmetric distribution. White
powder coat finished (minimum reflectivity 88%).
5.0”
24.0” x 48.0”
Lens: One piece symmetric/asymmetric acrylic lens gasketed (closed cell 100% pure
neoprene) in channel door frame. RFI shielded lens ( .375" metallic silver grid)
complies with Military Standard 461E. See below for other lense options.
Installation Detail
Lamps: See lamp options listed below. Lamps supplied by others.
Electrical: Standard ballasts - Electronic, less than 10% THD high performance instant
start universal voltage (120-277 volt). See options for other choices. Each fixture is
standard with one RFI line suppressor. Tested to surpass conducted emissions (CE102)
21.0”
of Mil. Std. 461e See Options for additional selections for ballasts and suppressor
circuits.
23.75”
(4) .875” KO's
Finish: White DuPont Alesta™ using Agion® silver ion antimicrobial powder coat
finish standard on all doorfames. See option SSP for satin polished stainless steel doors.
42.0”
48.0”
Installation: Adjustable Zee-brackets provide even support. Designed for proper
installation in standard 1" and 1.5" T-bar grid ceilings. Four .875" flattened and
silicone sealed knockouts for wiring. Note: This fixture is not for plaster or drywall
ceilings.
Listings: UL and CUL Listed for Wet Location. IBEW Label. Class 10,000, ISO-7
cleanspace compatible. EMC tested and labeled for Mil-Std 461E.
Ordering Information:
ML
- EG
-
-
Series
Installation Type
Material
ML
EG = T-Bar Grid
1 = CRS Hsg. & CRS Door
2 = CRS Hsg. & SS Door
3 = SS Hsg. & SS Door
4 = AL Hsg. & SS Door
(1 & 1.5” T-bar ceilings)
Size
Lamps
2x2 = 2'x2’ Housing
2, 3, 4 or 6/T8 = F17T8 17W T8 (G13)
1 or 2/T8U6 = F32T8/U/6 (6” U-Lamp, G13)
2 or 3/T8U1 = F31T8/U (1.625” U-Lamp, G13)
2, 3 or 4/BX = 40-Watt Biax (2G11)
2x4 = 2'x4’ Housing
2, 3, 4 or 6/T8 = F32T8 32W T8 (G13)
2, 3 or 4/T5 = F28WT5 28W T5 (G5)*
2, 3 or 4/T5HO = F54WT5 54W T5HO (G5)*
Voltage
Options
120V
277V
347V
UNV
FF = Fuse & Holder
FD = Two Fuses & Holders
FT = Three Fuses & Holders
ESB = Magnetic Ballast (T8 32W only)
EBPRS= Program Rapid Start Elect. Ballast
DIM = Electronic Dimming Ballast**
1/EM = One Lamp Emergency Ballast (700 L)
2/EM = Two Lamp Emergency Ballast (1300 L)
F/EM= Two Lamp Emergency Ballast (3000L)†
2/CIR= Two RFI Protected Switched Circuits
3/CIR= Three RFI Protected Switched Circuits
GG = NSF listed SealPro™ Gasket
SSP= Satin Polished Stainless Steel Door
P12/RFI= Prismatic P12 Acrylic w/RFI Grid
GL2= Two Green 550nm T8 lamps
**Dimming ballasts are 0-10vdc type by manufacturer of our choice unless specified. Use DIM/(Model
Name) to specify a certain dimming system.
†Externally Mounted Emergency ballast is secured to
top of fixture housing.
Kurtzon Lighting
Lighting
18 Kurtzon
www.Kurtzon.com
Med Lock Series
2x2 and 2x4 Recessed Flanged Luminaires for Surgical Suites
For Use in Continuous Row, Rectangle and Individual Layouts
ML04
Specifications:
Project:
Housing: Lapped and spot welded 20-gauge zinc coated CRS construction. All
seams of hole-free housing silicone sealed.
Fixture Type:
Door Frame: 20-gauge CRS or stainless steel channel door frame hinged to housing
with continuous stainless steel piano hinge. Secured with 2 captive stainless steel
fasteners.
Cross Section
Yoke
Gaskets: Neoprene, 100% pure, closed cell located at interface of door to housing and door to lens. See Option “GG” for SealPro™ NSF Listed closed cell
gasketing.
4.50”
Reflector: Full reflector panel designed to enhance asymmetric distribution. White
powder coat finished (minimum reflectivity 88%).
25.25”x 50.25”
To Table
Lens: One piece symmetric/asymmetric acrylic lens gasketed (closed cell 100% pure
neoprene) in channel door frame. RFI shielded lens ( .375" metallic silver grid)
complies with radiated emissions (RE101) of Military Standard 461E. Consult
factory for other lens options.
Ceiling Cutout
Lamps: See lamp options listed below. Lamps supplied by others.
Electrical: Standard ballasts - Electronic, less than 10% THD high performance
instant start universal voltage (120-277 volt). See options for other choices. Each
fixture is standard with one RFI line suppressor. Tested to surpass conducted
emissions (CE102) of Mil. Std. 461e See Options for additional selections for
ballasts and suppressor circuits.
24”
Finish: White DuPont Alesta™ using Agion® silver ion antimicrobial powder coat
finish standard. See option SSP for satin polished stainless steel doors.
49”
Installation: Yoke mounting standard. Flanges of adjoining fixtures are factory
removed to facilitate the installation in continuous rows mounting (CRM) without
overlapping flanges. Four .875" flattened and silicone sealed knockouts for wiring.
Listings: UL and CUL Listed for Wet Location. IBEW Label. EMC tested and
labeled for Mil-Std 461E.
Ordering Information:
ML
- F
-
-
Series
Installation Type
Material
ML
F = Flange
1 = CRS Hsg. & CRS Door
2 = CRS Hsg. & SS Door
Size
Lamps
Voltage
120V
277V
347V
UNV
2x2 = 2'x2' Housing
2, 3, 4 or 6/T8 = F17T8 17W T8 (G13)
1 or 2/T8U6 = F32T8/U/6 (6” U-Lamp, G13)
2 or 3/T8U1 = F31T8/U (1.625” U-Lamp, G13)
2, 3 or 4/BX = 40-Watt Biax (2G11)
2, 3, 4 or 6/T5HO = F24WT5 24W T5HO (G5)
2x4 = 2'x4' Housing
2, 3, 4 or 6/T8 = F32T8 32W T8 (G13)
2, 3, 4 or 6/T5 = F28WT5 28W T5 (G5)
2, 3, 4 or 6/T5HO = F54WT5 54W T5HO (G5)
Many installations of these fixtures are in continuous rows. The ML series is
unique in that it is designed to be used in this manner though it is standard as
an individual fixture. Kurtzon provides a layout guide to facilitate the planning and installation of CRM option fixtures. See facing page.
Kurtzon
Kurtzon Lighting
Lighting
Options
FF = Fuse & Holder
FD = Two Fuses & Holders
FT = Three Fuses & Holders
ESB = Magnetic Ballast (T8 32W only)
EBPRS= Program Rapid Start Ballast
DIM = Electronic Dimming Ballast**
1/EM = One Lamp Emergency Ballast (700 L)
2/EM = Two Lamp Emergency Ballast (1300 L)
F/EM= Two Lamp Emergency Ballast (3000L)†
2/CIR= Two RFI Protected Switched Circuits
3/CIR= Three RFI Protected Switched Circuits
GG = NSF listed SealPro™ Gasket
SSP= Satin Polished Stainless Steel Door
P12/RFI= Prismatic P12 Acrylic w/RFI Grid
PF= Plaster frame (For wet plaster ceilings)
GL2= Two Green 550nm T8 lamps
**Dimming ballasts are 0-10vdc type by manufacturer of our choice unless specified. Use DIM/(Model
Name) to specify a certain dimming system.
†Externally Mounted Emergency ballast is secured to
top of fixture housing.
www.Kurtzon.com
19
Med Lock Series
ML06
ML-G 2x2 and 2x4 Recessed 1" & 1.5" T-Bar Grid Luminaires for Surgical Suites
Specifications:
Project:
Housing: One piece seam welded 20-gauge CRS, aluminum or stainless steel
construction. Fully white powder coated. All seams of hole-free housing silicone
sealed. Designed for proper installation in standard 1" and 1.5" T-bar grid ceilings..
Fixture Type:
Door Frame: 20-gauge CRS or stainless steel channel door frame hinged to housing
with continuous stainless steel piano hinge. Secured with 2 captive stainless steel
fasteners. See Options for 85 PSI rating (HD-85).
Cross Section
Gaskets: Neoprene, 100% pure, closed cell located at interface of door to housing and door to lens. See Option “GG” for SealPro™ NSF Listed closed cell
gasketing.
5.0”
24”x 48”
Reflector: Full reflector panel designed to enhance asymmetric distribution. White
powder coat finished (minimum reflectivity 88%).
Lens: One piece symmetric/asymmetric acrylic lens gasketed (closed cell 100% pure
neoprene) in channel door frame. RFI shielded lens ( .375" metallic silver grid)
complies with Military Standard 461E. Consult factory for other lense options.
Installation Detail
Lamps: See lamp options listed below. Lamps supplied by others.
(4) .875” KO’s
Electrical: Standard ballasts - Electronic, high power factor, U.L. listed, Class P,
CBM/ETL certified. Each fixture is standard with one RFI line suppressor. See
Options for additional selections for ballasts and suppressors.
24”
Finish: White DuPont Alesta™ using Agion® silver ion antimicrobial powder
coat finish standard for both doors and housings. See option SSP for satin polished
stainless steel doors.
48”
Installation: Adjustable Zee-brackets provide even support. See options for
integrated seismic support brackets. Four .875" flattened and silicone sealed
knockouts for wiring. Note: This fixture is not for plaster or drywall ceilings.
Listings: UL and CUL Listed for Wet Location. IBEW Label. EMC tested and
labeled for Mil-Std 461E.
Ordering Information:
ML
- G
-
-
Series
Installation Type
Material
ML
G = Grid
1" & 1.5" T-bar
1 = CRS Hsg. & CRS Door
2 = CRS Hsg. & SS Door
3 = SS Hsg. & SS Door
4 = Alum. Hsg. & SS Door
Size
Lamps
Voltage
120V
277V
347V
UNV
2x2 = 2'x2' Housing
2, 3, 4 or 6/T8 = F17T8 17W T8 (G13)
1 or 2/T8U6 = F32T8/U/6 (6” U-Lamp, G13)
2 or 3/T8U1 = F31T8/U (1.625” U-Lamp, G13)
2, 3 or 4/BX = 40-Watt Biax (2G11)
2, 3, 4 or 6/T5HO = F24WT5 24W T5HO (G5)
2x4 = 2'x4' Housing
2, 3, 4 or 6/T8 = F32T8 32W T8 (G13)
2, 3, 4 or 6/T5 = F28WT5 28W T5 (G5)
2, 3, 4 or 6/T5HO = F54WT5 54W T5HO (G5)
Options
FF = Fuse & Holder
FD = Two Fuses & Holders
FT = Three Fuses & Holders
ESB = Magnetic Ballast (T8 32W only)
EBPRS= Program Rapid Start Elect. Ballast
DIM = Electronic Dimming Ballast**
1/EM = One Lamp Emergency Ballast (700 L)
2/EM = Two Lamp Emergency Ballast (1300 L)
F/EM= Two Lamp Emergency Ballast (3000L)†
2/CIR= Two RFI Protected Switched Circuits
3/CIR= Three RFI Protected Switched Circuits
GG = NSF listed SealPro™ Gasket
SSP= Satin Polished Stainless Steel Door
P12/RFI= Prismatic P12 Acrylic w/RFI Grid
GL2= Two Green 550nm T8 lamps
**Dimming ballasts are 0-10vdc type by manufacturer of our choice unless specified. Use DIM/(Model
Name) to specify a certain dimming system.
†Externally Mounted Emergency ballast is secured to
top of fixture housing.
Kurtzon Lighting
Lighting
20 Kurtzon
www.Kurtzon.com
Med Lock Series
2x2 and 2x4 Recessed Flanged Luminaires for Advanced Surgical Suites
For Use in Straight Rows or Individual Layouts Only
Specifications:
ML08
Project:
Housing: One piece, seam welded, hole free 18-gauge aluminum construction. Fully
white powder coated.
Fixture Type:
Door Frame: 20-gauge CRS or type 304 stainless steel one piece inset door frame
hinged to housing with two stainless steel cables. Secured by captive stainless steel
screws.
Cross Section
Toggle Arms
Gaskets: NSF Listed extruded closed cell Nitrile gasketing located at interface of door
and housing. NSF listed silicone seals the door to the lens.
Asymmetric
Distribution
Reflector: Die formed metal with high reflectance white polyester powder coat finish.
(minimum reflectivity 88%)
4.50”
25.0” x 49.5”
Lens: Two piece acrylic lens system with an external clear lens for easy cleaning and
a linear prismatic acrylic lens internal for light control. RFI shielded with a .375"
metallic conductive grid that complies with radiated emissions (RE101) of Military
Standard 461E. Consult factory for other lens options.
Ceiling Cutout
Lamps: See lamp options listed below. Lamps supplied by others.
Electrical: Standard ballasts - Electronic, less than 10% THD high performance instant
start universal voltage (120-277 volt). See options for other choices. Each fixture is
standard with one RFI line suppressor. Tested to surpass conducted emissions (CE102)
of Mil. Std. 461e See Options for additional selections for ballasts and suppressor
circuits.
24.0”
Finish: White DuPont Alesta™ using Agion® silver ion antimicrobial powder coat
finish standard for both doors and housings. See option SSP for satin polished stainless
steel doors.
24.5”
Installation: Adjustable toggle arm mounting standard. See Options for yoke
mounting system (YOKE). Four .875” flattened and silicone sealed knockouts for
wiring. Suitable for through wiring.
24.0”
Listings: UL and CUL Listed for Wet Locations. Cleanroom ISO14644-1 Class 6
(Fed Std-209E class 1,000) IBEW Union Label. EMC tested and labeled for Mil-Std
461E. NSF-2 Listed, IP-65 dust and water resistance.
48.5”
Ordering Information:
ML
- OF
-
-
-
Series
Installation Type
Material
Size
ML
OF = Flange
4= Alum. Hsg. & SS Door
5= Alum. Hsg. & Alum. Door
Lamps
Voltage
120V
277V
347V
UNV
2x2 = 2'x2' Housing
2, 3, 4 or 6/T8 = F17T8 17W T8 (G13)
1 or 2/T8U6 = F32T8/U/6 (6” U-Lamp, G13)
2 or 3/T8U1 = F31T8/U (1.625” U-Lamp, G13)
2, 3 or 4/BX = 40-Watt Biax (2G11)
2, 3, 4 or 6/T5HO = F24WT5 24W T5HO (G5)
2x4 = 2'x4' Housing
2, 3, 4 or 6/T8 = F32T8 32W T8 (G13)
2, 3, 4 or 6/T5 = F28WT5 28W T5 (G5)
2, 3, 4 or 6/T5HO = F54WT5 54W T5HO (G5)
**Dimming ballasts are 0-10vdc type by manufacturer of our
choice unless specified. Use DIM/(Model Name) to specify a
certain dimming system.
Options
FF = Fuse & Holder
FD = Two Fuses & Holders
FT = Three Fuses & Holders
ESB = Magnetic Ballast (T8 32W only)
EBPRS= Program Rapid Start Ballast
DIM = Electronic Dimming Ballast**
1/EM = One Lamp Emergency Ballast (700 L)
2/EM = Two Lamp Emergency Ballast (1300 L)
F/EM= Two Lamp Emergency Ballast (3000L)†
2/CIR= Two RFI Protected Switched Circuits
3/CIR= Three RFI Protected Switched Circuits
GG = NSF listed SealPro™ Gasket
SSP= Satin Polished SS Door
P12/RFI= Prismatic P12 Acrylic w/RFI Grid
PF= Plaster frame (For wet plaster ceilings)
GL2= Two Green 550nm T8 lamps
CRM= Continuous Row Mounting
YOKE= Yoke Mounting System
†Externally Mounted Emergency ballast is secured to top of fixture
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
21
Med Lock Series
4' Luminaires for Corner Mount Installation
ML11
Project:
Specifications:
Fixture Type:
Housing: One piece, seam welded, hole free 20-gauge CRS, stainless
steel or aluminum construction.
Door Frame: 20-gauge CRS or type 304 stainless steel channel door
frame hinged to housing with two stainless steel cables. Secured by captive stainless steel screws. See Options for 85 PSI rating (HD-85).
Cross Section
Gaskets: Neoprene, 100% pure, closed cell located at interface of door
to housing and door to lens. See Option “GG” for SealPro™ NSF
Listed closed cell gasketing.
7.50”
Reflector: Die formed metal with high reflectance white polyester
powder coat finish. (minimum reflectivity 88%)
7.50”
Lens: High durability .135” thick virgin acrylic with P12 prismatic
pattern. See “Options” for other choices.
8.12”
Lamps: Select lamp options listed below. Lamps supplied by others.
Electrical: Standard ballast - Electronic less than 10% THD high
performance instant start universal voltage (120-277 volt). See options
for other choices.
Finish: Gloss white high reflectance 1000 hr. salt spray polyester powder coat finish standard for all housings and CRS door frames. Stainless steel doorframes are satin polished unless option WHT is chosen.
See "SSP" option for satin (#4) polished stainless steel housings.
Installation Detail
Top and Rear View
36.0”
.312 Mounting Holes
Installation: Four .312” holes for surface mounting. Silicone sealed
knockouts provided for conduit entry in six locations. Suitable for
through wiring.
7.50”
.875 K.O.'s
42.12”
48.12”
Listings: UL and CUL Listed for Wet Locations. IBEW Label.
Ordering Information:
ML
- COR
-
-
Series
Installation Type
ML
COR = Corner Mount 1 = CRS Hsg. & CRS Door
2 = CRS Hsg. & SS Door
3 = SS Hsg. & SS Door
4 = Alum. Hsg. & SS Door
40 = 4' Housing
Material
Size
Lamps
Voltage
120V
277V
347V
UNV
1, 2 or 3/T8 = F32T8 32-Watt T8
1 or 2/T5 = F28W/T5 28-Watt T5 (G5)
1 or 2/T5HO = F54W/T5 54-Watt T5HO (G5)
Kurtzon Lighting
Lighting
22 Kurtzon
Options
Options
FF = Fuse & Holder
FD = Two Fuses & Holders
2/EB = Two Ballasts, (Two Circuits)
EBL = -20°F Electronic Ballast*
EBPRS= Program Rapid Start Ballast
1/EM = 1 Lamp Battery Pack (700L)
2/EM = 2 Lamp Battery Pack (1300L)
TP = Stainless Steel Tamperproof Fasteners
HD85 = 85 P.S.I. Hosedown
GG = NSF listed SealPro™ Gasket
WHT= White Finished Stainless Steel Door Frame
LEX = .125” Prismatic Polycarbonate
PA= Prismatic P12 Pattern Clear Acrylic
A19= Prismatic P19 Pattern Clear Acrylic
HIA= High Impact P12 Pattern Acrylic
TG= Prismatic (C73) Tempered Glass
SSP = Stainless Steel Polished Housing
www.Kurtzon.com
ML12
Med Lock Series
Six Inch Aperture Recessed Non-magnetic Downlites for MRI Installation
Specifications:
Housing: Non-magnetic stainless and aluminum plaster ring and base
assembly supports reflector and lampholder housing. Housing can is
adjustable in vertical depth and removable for electrical inspection.
Reflector: Injection molded plastic with specular aluminum coating.
Baffle: White elliptical coilex style with spring supports. Roll formed
aluminum trim flange to cover ceiling cutout.
8.0”
Lens: Injection molded acrylic prismatic diffuser seals dust from reflector
and LED area.
LED: Titan Turbo Trucolor 24w array with thermal and ESD
management systems.
10.5”
Electrical: Cast aluminum J-Box with two threaded conduit entrance
points. Non-magnetic splices provided. All electrical hardware and
interconnecting whip are non magnetic.
Remote Driver: 120-277v AC power supply with 1/2 inch trade size
conduit entry points for low and line voltage connection. Mounting feet
at each end for surface attachment at a location within 100 feet of the
Luminaires.
8.0”
Finish: White finished trim ring and white molded baffle.
Installation: .
Listings: (Pending )UL Listed for type Non-IC applications. IBEW
Label.
Ordering Information:
ML
- MRV
-4
-6
Series
Installation Type
Material
ML
MRV = Recessed
4 =Aluminum/Stainless steel
6 = 6 Inch Aperture
-LED
Size
LED
- UNV
Voltage
UNV= 120-277V
LED = One 24W Titan Turbo Trucolor array
Project:
Fixture Type:
Catalog Number:
Approved by:
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
23
Kurtzon Lighting
Lighting
24 Kurtzon
www.Kurtzon.com
Kurtzon Lighting
Lighting
25 Kurtzon
www.Kurtzon.com
Med Lock Series
2x2 and 2x4 Recessed Flanged Luminaires for MRI Featured Advanced Surgical Suites
For Use in Pairs of Master and Satellite Layouts Only
Specifications:
ADS
Project:
Housing: One piece, seam welded, hole free 18-gauge aluminum construction. Fully
white powder coated. Complete construction is non-magnetic.
Fixture Type:
Door Frame: 20-gauge 304 stainless steel or aluminum one piece inset door frame
hinged to housing with two stainless steel cables. Secured by captive stainless steel
screws.
Cross Section
Toggle Arms
Gaskets: NSF Listed extruded closed cell Nitrile gasketing located at interface of door
and housing. NSF listed silicone seals the door to the lens.
Asymmetric
Distribution
Reflector: Die formed aluminum with high reflectance white polyester powder coat
finish. (minimum reflectivity 88%)
4.50”
25.25” x 50.25”
Lens: Two piece acrylic lens system with an external clear lens for easy cleaning and
a linear prismatic acrylic lens internal for light control. RFI shielded with a .375"
metallic conductive grid that complies with radiated emissions (RE101) of Military
Standard 461E. Consult factory for other lens options.
Ceiling Cutout
Lamps: See lamp options listed below. Lamps supplied by others.
Electrical: Standard ballasts - Electronic, less than 10% THD high performance instant
start universal voltage (120-277 volt). Each master luminaire is standard with two
RFI line suppressors. Tested to surpass conducted emissions (CE102) of Mil. Std.
461e See Options for additional selections for ballasts and suppressor circuits. Satalite
fixtures are wired for secondary ciruit wiring only. Whips by others.
24.0”
Finish: White DuPont Alesta™ using Agion® silver ion antimicrobial powder coat
finish standard for both doors and housings. See option SSP for satin polished stainless
steel doors.
25”
Installation: Non magnetic yoke mounting system standard. Four .875” flattened and
silicone sealed knockouts for wiring. Suitable for through wiring. Master luminaires
suitable for mounting outside the 5 gause line. Satellite luminaires may be mounted
within the 5 gause line but all fixtures must be de-energized during MRI operation.
24.0”
Listings: UL and CUL Listed for Wet Locations. Cleanroom ISO14644-1 Class 6
(Fed Std-209E class 1,000) IBEW Union Label. EMC tested and labeled for Mil-Std
461E.
49”
Ordering Information:
ML
- MRIOF
-5
-2X4
-6/T8
Series
Installation Type
Material
Size
ML
MRIOF = Flange
4= Alum. Hsg. & SS Door
5= Alum. Hsg. & Alum. Door
Lamps
-UNV
Voltage
120V
277V
347V
UNV
2x2 = 2'x2' Housing
2, 3, 4 or 6/T8 = F17T8 17W T8 (G13)
1 or 2/T8U6 = F32T8/U/6 (6” U-Lamp, G13)
2 or 3/T8U1 = F31T8/U (1.625” U-Lamp, G13)
2, 3 or 4/BX = 40-Watt Biax (2G11)
2, 3, 4 or 6/T5HO = F24WT5 24W T5HO (G5)
2x4 = 2'x4' Housing
2, 3, 4 or 6/T8 = F32T8 32W T8 (G13)
2, 3, 4 or 6/T5 = F28WT5 28W T5 (G5)
2, 3, 4 or 6/T5HO = F54WT5 54W T5HO (G5)
Kurtzon Lighting
Lighting
26 Kurtzon
Options
EBPRS= Program Rapid Start Ballast
2/CIR= Two RFI Protected Switched Circuits Per
Fixture.
SSP= Satin Polished SS Door
P12/RFI= Prismatic P12 Acrylic w/RFI Grid
GL2= Two Green 550nm T8 lamps
CRM= Continuous Row Mounting
MASTER= Master Luminaire (contains RFI filters
and ballasts)
SAT= Satellite (power supplied from master)
www.Kurtzon.com
FILTER
Med Lock Series
2x2 and 2x4 Recessed Flanged Luminaires for MRI Featured Advanced Surgical Suites
For Use in Pairs of Master and Satellite Layouts Only
MASTER
ADS
SAT
ATELL
ELLITE
SATELLITE
cirtemmysA
noitubirtsiD
5 GA
USE
LIN
E
Asymmetric
Distribution
Kurtzon
Kurtzon Lighting
Lighting
www.Kurtzon.com
27
Med Lock Series
2x2 and 2x4 Recessed 1" & 1.5" T-Bar Grid Luminaires for Graphic Ceilings
Specifications:
ML17
Project:
Housing: One piece seam welded 20-gauge CRS, stainless steel or aluminium
construction. All seams of hole-free housing silicone sealed.
Fixture Type:
Door Frame: 20-gauge CRS or stainless steel channel door frame hinged to housing
with two stainless steel cables. Secured by captive stainless steel screws. See Options for
85 PSI rating (HD-85).
Gaskets: Neoprene, 100% pure, closed cell located at interface of door to housing and
door to lens.
Reflector: White powder coat finished (minimum reflectivity 88%).
Lens: Graphic lens overlays a clear washable room side acrylic lens that is gasketed
(closed cell 100% pure neoprene) in channel door frame. Specify graphic panels below.
Lamps: See lamp options listed below. Lamps supplied by others.
Cross Section
Electrical: Standard ballasts - Electronic, less than 10% THD high performance instant
start universal voltage (120-277 volt). See options for other choices. See Options for
additional selections for ballasts and suppressor circuits.
5.0”
Finish: White DuPont Alesta™ using Agion® silver ion antimicrobial powder coat
finish standard on all doorfames.
24.0” x 48.0”
Installation: Adjustable Zee-brackets provide even support. Designed for proper
installation in standard 1" and 1.5" T-bar grid ceilings. Four .875" flattened and
silicone sealed knockouts for wiring. Note: This fixture is not for plaster or drywall
ceilings.
Installation Detail
Listings: UL and CUL Listed for Wet Location. IBEW Label. Class 10,000, ISO-7
cleanspace compatible.
21.0”
23.75”
(4) .875” KO's
42.0”
48.0”
Ordering Information:
ML
- AG
-
-
Series
Installation Type
Material
ML
AG = T-Bar Grid
1 = CRS Hsg. & CRS Door
2 = CRS Hsg. & SS Door
3 = SS Hsg. & SS Door
4 = AL Hsg. & SS Door
(1 & 1.5” T-bar ceilings)
Size
Lamps
2x2 = 2'x2’ Housing
2, 3, 4 or 6/T8 = F17T8 17W T8 (G13)
1 or 2/T8U6 = F32T8/U/6 (6” U-Lamp, G13)
2 or 3/T8U1 = F31T8/U (1.625” U-Lamp, G13)
2, 3 or 4/BX = 40-Watt Biax (2G11)
2x4 = 2'x4’ Housing
2, 3, 4 or 6/T8 = F32T8 32W T8 (G13)
2, 3 or 4/T5 = F28WT5 28W T5 (G5)*
2, 3 or 4/T5HO = F54WT5 54W T5HO (G5)*
Voltage
Options
120V
277V
347V
UNV
FF = Fuse & Holder
EBPRS= Program Rapid Start Elect. Ballast
DIM = Electronic Dimming Ballast**
1/EM = One Lamp Emergency Ballast (700 L)
2/EM = Two Lamp Emergency Ballast (1300 L)
GG = NSF listed SealPro™ Gasket
Graphic Panel Options
CUMB1= Cumulus Dense Clouds
CUMB2= Cumulus Scattered Clouds
STRATUS = Stratus Dense Clouds
CIRRUS= Cirrus Dense Clouds
ARRAY= Birch Trees Array
ARRAY2= Cumulus Array
**Dimming ballasts are 0-10vdc type by manufacturer of our choice unless specified. Use DIM/(Model
Name) to specify a certain dimming system.
†Externally Mounted Emergency ballast is secured to
top of fixture housing.
Kurtzon Lighting
Lighting
28 Kurtzon
www.Kurtzon.com
RD01
Round Dome Series
3.07
Two and Four Foot Recessed for Flanged and T-bar Grid Installation.
Specification:
Housing: Lapped and spot welded 20 ga. CRS construction. Designed
for installation Plaster or Drywall ceilings before ceiling closure and in
T-bar grid systems
Door Frame: One piece .125" thick Aluminum rigid extruded ring supports the lens. Concealed torsion springs securely support the frame and
provide for tooless entry.
Reflector: White powder coat finished (minimum reflectivity 88%).
Lens: One piece white translucent acrylic lens secured in doorframe.
Available in three profiles: Concave, convex and flat. See "Options" below to specify.
Electrical: Standard ballast - Electronic less than 10% THD high performance instant start universal voltage (120-277 volt). See options for
other choices.
Cross Section
(Concave lense shown)
Installation: Four .375" dia. holes provided for fixture support at each
corner. Four wire attachment points are provided for suplimental seismic support. T-bar grid support brackets for proper fit within standard
1 inch T-bar grid systems.
48.00”
7.10”
Listings: UL and CUL listed for Dry and Damp locations. IBEW labeled. AFL/CIO Union Made.
42.62”
44.37”
Note: Due to the nature of a circular aperture and the square housing,
this fixture must be installed before ceiling closure.
42.12”
7.10”
36.75”
38.25”
24.15”
7.10”
20.06”
21.68”
Ordering Information:
RD
Series
RD
- F/G
Installation Type
F/G= Flanged
& T-bar Grid
-
Material
Size
Lamps
1 = CRS Hsg. & Alum. Door
Voltage
120V
277V
347V
UNV
20= 2' Housing
2, 3, 4 or 6/T8 = F17T8 17W T8 (G13)
2, 3, 4 or 6/T5 = F14WT5 14W T5 (G5)
2, 3, 4 or 6/T5HO = F24WT5 24W T5HO (G5)
2 or 3/T8U1 = F32T8/U 1.6" 32W U-Lamp T8
30= 3' Housing
2, 3, 4, 6 or 8/T8 = F25T8 25W T8 (G13)
2, 3, 4, 6 or 8/T5 = F21WT5 21W T5 (G5)
2, 3, 4 or 6/T5HO = F39WT5 39W T5HO (G5)
40= 4' Housing
2, 3, 4, 6 or 8/T8 = F32T8 32W T8 (G13)
2, 3, 4, 6 or 8/T5 = F28WT5 28W T5 (G5)
2, 3, 4 or 6/T5HO = F54WT5 54W T5HO (G5)
Kurtzon
Kurtzon Lighting
Lighting
Options
FF = Fuse & Holder
FD = Two Fuses & Holders
2/EB = Two Ballasts, (Two Circuits)*
EBL = -20°F Electronic Ballast*
EBPRS= Program Rapid Start Ballast*
1/EM = 1 Lamp Battery Pack (700L)*
2/EM = 2 Lamp Battery Pack (1300L)*
CC= Concave lense
CV= Convex lense
FL= Flat lens
www.Kurtzon.com
29
Kurtzon Lighting
Quality
Quality Lighting
Lighting Made
Made in
in Chicago,
Chicago, IL
IL since
since 1898
1898
Medical Brochure
WWW.KURTZON.COM
800-837-8937
1420 S. Talman Ave Chicago, IL
Kurtzon Lighting
Lighting
30 Kurtzon
www.Kurtzon.com