Modular Medium and Large (T8 Fluorescent) with Emergency

Installation Instructions for
980MODUMLT8-EM7
Modular Medium and Large (T8 Fluorescent)
with Emergency Backup for 277V Locations
PW5_17L2HBW,
PW5_25L2HBW
Outdoor
GENERAL PRODUCT INFORMATION:
This product can mount to either a 4" square electrical box with
round plaster ring or an octagon electrical box.
This product is suitable for wet locations.
CAUTION - RISK OF FIRE
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.
Install the Fixture Base
1A
1B
1
1
1
1
1
1
3
3
3
3
3
3
1
Remove all the cap screws around the perimeter of the cover.
3
Remove the six Phillips-head screws on the reflector.
2
Pull the cover off of the housing.
4
Lift the reflector out of the housing.
1
1.0
1C
1E
NIPPLE
#8-32 SCREW
5
11
6
CROSSBAR
ASSEMBLY
6
11
ELECTRICAL BOX HOLE
5
Feed the switched, unswitched, and neutral/common power
line wires through the crossbar nipple.
6
Mount the crossbar assembly to the electrical box holes with
the two #8-32 screws provided.
7
Connect the crossbar to a suitable ground according to local
electrical codes.
10
ANCHOR
10
Install the anchors for the lag bolts at the points marked on
the wall.
11
Apply caulk around the anchor points and the electrical box.
1D
1F
9
13
8
12
9
13
RUBBER WASHER
LAG BOLT
8
Place the housing on the crossbar nipple
9
Mark the location of the end holes in the housing onto the
wall and remove the housing.
METAL WASHER
TEST SWITCH
IMPORTANT: Make sure the test switch is at the
bottom when mounting the housing!
2
12
Mount the housing to the crossbar nipple with the nut and
lock washer provided.
13
Anchor the housing to the wall with lag bolts through the
metal and rubber washers provided.
Do not overtighten the lag bolts.
Install the Lamps
1G
2A
19
2
2
2
2
19
18
15
19
14
16
17
19
19
14
Connect the common/neutral power line wire to the white
fixture wire marked “COM” with a wire nut.
15
Connect the switched hot power line wire to the black
fixture wire marked “SWITCHED HOT” with a wire nut.
16
Connect the unswitched hot power line wire to the orange
fixture wire marked “ALWAYS HOT” with a wire nut.
17
Medium versions use MAX 17 Watt type T8 linear
fluorescent lamp.
Large versions use MAX 25 Watt type T8 linear
fluorescent lamp.
Connect the red test switch wire to the loose red fixture wire
with a wire nut. Connect the white test switch wire to the
loose red/white fixture wire with a wire nut.
18
Plug the white/black unit connector wires together.
CAUTION: RISK OF SHOCK! Plug these wires in only
after all other connections have been made.
19
Reinstall the reflector into the housing and tighten all six
screws to hold it in place. Place the reflector so the end
marked “THIS SIDE UP” is at the top.
3
1
Line up the lamp pins on both ends with the opening on the
sockets.
2
Insert the pins all the way into the sockets and turn the lamp
to lock it in place.
3
Reinstall the front cover on to the housing and fully tighten all
six cap screws. Tighten all the cap screws evenly to prevent
the cover from flexing, which could cause the glass to break.
Install the Decorative Cover
3A
3B
2
2
2
2
INDUSTRIAL
AND TUBULAR
1
NEW YORK
2
Slide the decorative cover onto the fixture base.
For Industrial and Tubular decorative covers (left), place the
acrylic shade inside the frame and slide the cover on from the
front.
For New York decorative covers (right), line up the tracks on
the fixture with the guides inside the cover, and slide the cover
on from the top.
For Industrial and Tubular decorative covers, line up the
holes in the decorative cover and acrylic shade with the holes
in the fixture base.Attach screws through these holes to
secure the cover.
For New York decorative covers (shown), line up the holes in
the decorative cover with the holes in the fixture base.Attach
screws through these holes to secure the cover.
SAVE THESE INSTRUCTIONS!
7400 Linder Ave, Skokie, IL 60077
800.323.3226 - 847.626.6300
www.lbllighting.com
© 2014 LBL Lighting.All rights reserved.The "LBL Lighting" graphic is a
registered trademark of LBL Lighting. LBL Lighting reserves the right to
change specifications for product improvements without notification.
A Generation Brands Company
4