HINGED SPLICE BOX MOUNT IAP1 SERIES 16" PRISMATIC REFLECTOR — EZ BAY PLUS ® 3/4" Conduit Stem (By others) Ballast (Heat sinked on 2 sides) Hinged Splice Box 6.6" (169 mm) 1.6" (40 mm) 14.0" (356 mm) Thermal Chimney (Allows socket heat to escape fixture) 5.8" (148 mm) 1.6" (40 mm) Ignitor (Where required) 5.8" (148 mm) Capacitor (Heat sinked to housing) 5.8" (147 mm) 22.6" (574 mm) 16.8" * (427 mm) Housing Finish color: white 11.0" (278 mm) Fixed Position Mounting Notes: * 400W MH and 350W and greater PSMH use a spacer between the reflector and the housing, adding 2" (51 mm) to overall fixture height. 16.8" (426 mm) 11.0" (278 mm) Lamp (Included) Acrylic Prismatic Reflector SPEC # SPEC # SPEC # SPEC # SPEC # SPEC # SPEC # SPEC # SPEC # SPEC # SPEC # WATTAGE 16.2" (412 mm) Shown with Adjustable Neck Housing Option CATALOG # (a) VOLTAGE SUFFIX KEY PULSE START METAL HALIDE 150W PSMH IAP1615-(a)(b)O 200W PSMH IAP1620-(a)(b)O 250W PSMH IAP1625-(a)(b)O 320W PSMH IAP1632-(a)(b)O 350W PSMH IAP1635-(a)(b)O 400W PSMH IAP1640-(a)(b)O 450W PSMH IAP1645-(a)(b)O HIGH PRESSURE SODIUM 150W HPS IAP1515-(a)(b) 250W HPS IAP1525-(a)(b) 400W HPS IAP1540-(a)(b) M T 1 2 27 3 4 5 6 Specify (a) Voltage & (b) Options. 2-Level available – consult factory. Reduced envelope ED28 lamp. (b) OPTIONS (factory-installed) A 120/208/240/277V (Standard) 120/277/347V (Canada Only) (400W max.) 120V 277V 277V Reactor (150 – 400W PSMH Only) 208V 240V 480V 347V (Canada Only) Prismatic Drop Acrylic Lens (250W max.) (N/A with Wire Guard) B Optical Chamber Air Filter (use only with “A”, “E”, or “Y” lens) E -(a)F K N For voltage availability outside the US and Canada, see Bulletin TD-9 or contact your Ruud Lighting authorized International Distributor. O Q Notes W Y Clear Flat Acrylic Lens (250W max.) Fusing 2-Level Integrated Sensor Adjustable Neck Housing For narrow to wide distribution Open-rated Lamp (Standard 150-450W PSMH) Quartz Standby (delay relay w/100W quartz lamp) (N/A on 277V Reactor) Wire Guard (use with “E” lens) Prismatic Conical Acrylic Lens (250W max.) (N/A with Wire Guard) Specify (a) Single Voltage — See Voltage Suffix Key 250W, 320W or 400W PSMH GENERAL DESCRIPTION Fixture is constructed of an aluminum diecast ballast housing with a thermal chimney separating the ballast core and coil from the capacitor and other components. Factory set for medium distribution. Optional steel neck housing holds the reflector to the ballast compartment and provides multiple socket positions for wide to narrow distributions. Reflector is precision injection-molded acrylic. Brightened and anodized aluminum fluted collar adds support to reflector while improving photometric distribution. Fixtures with enclosed rated lamps (“E” suffix) include a clear, acrylic flat lens. Fixtures supplied with pulse start system (PSMH) feature open-rated lamps and open-rated sockets. Hinged Splice Box mount is designed for surface or pendant mounting configurations and has two 3/4' and six 1/2' conduit knockouts on the sides and one 3/4' knockout and mounting holes for common junction boxes on the top. Not intended for use in environments containing airborne corrosive agents such as chemical solvents, cleaners or cutting fluids. ELECTRICAL Fixture includes mogul-base lamp; coated for PSMH, clear for HPS. Pulse-rated porcelain open, 4kv-rated screw-shell-type lampholder with spring-loaded center contact. Enclosed rated for HPS only. Lamp ignitor included where required. Ballast assemblies are high-power factor and consist of the following circuit types: 277V Reactor 150 – 400W PSMH HX — High Reactance 150W PSMH, 150W HPS CWA — Constant Wattage Autotransformer 200 – 450W PSMH; 250 – 400W HPS; 150W PSMH – 480V ACCESSORIES SC-5 WG-AP Safety Cable with Hang-Fast (5'/1.5 m) Wire Guard (Not for use with lens enclosures) WG-AP/OC Wire Guard with Relamp Hole (Not for use with lens enclosures) FINISH White powdercoat finish. The finish is covered by our seven-year limited warranty. PATENTS 6,394,869; 6,467,927; 6,867,959; 6,974,230; 7,210,826; 7,319,593; 7,350,940; 7,284,877; Patents Pending LABELS UL and cUL Listed for damp locations and for a maximum ambient temperature of 40°C; most wattages higher – See Technical Data Sheet TD-12 on our web site. © 2012 Ruud Lighting, Inc. – A Cree Company. All rights reserved. The information in this document is subject to change without notice. ® 9201 Washington Avenue • Racine, Wisconsin 53406-3772 • PHONE: (800) 236-7000 • FAX: (800) 236-7500 • WEB: www.ruudlightingdirect.com Rev. 07/05/12 An Advanced Lighting Technologies Company Advanced Lighting Technologies Australia Inc Advanced Lighting Technologies New Zealand Ltd Advanced Lighting Technologies Asia Pte Ltd 110 Lewis Road, Wantirna South, VIC 3152 8 Boeing Place, Mount Maunganui Block 4008, Ang Mo Kio Avenue 10, #04-06, Techplace 1 Australia New Zealand Singapore 61 03 9800 5600 64 07 579 0163 65 6844 2338 www.adlt.com.au www.adlt.co.nz www.adlt.com.sg HINGED SPLICE BOX MOUNT IAP1 SERIES 16" PRISMATIC REFLECTOR — EZ BAY PLUS® High Pressure Sodium 120° 90° 60° 8000 12000 Zonal Lumens and Percentages Zone Lumens 8000 % Lamp 0-30 4157 15.12 0-40 9277 33.74 0-60 18790 68.33 0-90 21099 76.73 40-90 11822 42.99 12000 60-90 2309 8.40 90-180 3761 13.68 0-180 24861 90.41 30° Angle 45° 55° 16000 65° cc = .5 w = .3 75° 85°= 1.8 SC 16000 969 REFLECTANCES: 861 Efficiency7 5=3 90.04%; SC = 1.8; S/MH = 1.2 Beta 646 90˚ 60° Cd/sq. m 81477 25524 8313 fc = .2 6330 7797 Metric 70 61.04 .1 7 .6 1.00 50 55.8 120° 0.85 0.72 0.61 0.53 0.45 0.39 0.33 0.27 0.23 0.19 0.92 0.85 0.78 0.72 0.66 0.60 0.55 0.50 0.46 0.42 30 93.0 .2 1.00 91.00 0.89 0.86 90° 0.79 0.74 0.71 0.65 0.63 0.57 0.56 0.50 0.50 0.43 0.44 0.37 0.39 60° 0.32 0.34 0.27 0.30 0.23 10 50 50 30 10 130.2 0.7 1.00 1 0.93 0.83 0.82 0.70 0.74 0.60 0.66 0.52 0.59 0.44 0.53 0.38 0.47 0.32 0.41 0.27 0.37 0.23 0.32 0.19 0.28 0.93 0.80 0.70 0.61 0.54 0.47 0.41 0.35 0.30 0.26 0.22 50 1 2 . 2 0.86 0.86 0.93 0.78 0.77 0.75 0.67 0.69 0.66 0.57 0.62 0.58 0.50 0.56 0.51 0.43 0.50 0.45 0.36 0.44 0.39 0.31 4000 0.39 0.34 0.26 0.35 0.29 0.22 0.30 0.25 0.18 0.27 0.21 8000 Initial Footcandles 30 30 10 167.4 120° 10.86 3.7 0.73 0.63 0.55 0.48 0.41 0.35 0.29 0.25 0.21 0.17 10 30 50 204.6 0.80 0.71 0.65 0.58 0.52 0.47 0.42 0.37 0.32 0.29 0.25 10 241.8 .3 0.801 50.80 0.70 0.68 90° 0.62 0.60 0.55 0.52 0.49 0.46 0.43 0.39 0.37 0.34 0.32 0.28 60° 0.28 0.24 0.24 0.20 0.20 0.16 REFLECTANCES: cc = .5 70 60 w = .3 fc = .2 12000 30° 40 30 16000RCR 20 10 S Q . F T. P E R 0 FIXTURE Ruud F T. B E T W E E N FIXTURES 15 16000 = 3 200 10 1000 600 20 25 30 400W HPS 538 100M100Y 1800 1400 35 40 323 CC 80 70 50 215 WALL 70 50 30 10 RCR 70 = 503 30 10 50 30 108 RCR SQ. M PER F I X T U R E0 01.05 1.05 1.05 1.05 1.00 1.00 1.00 1.00 0.92 0.92 130.2 93.0 55.8 18.6 0.95 0.91 0.87 0.83 0.91 0.87 0.84 0.80 0.80 0.78 METERS1 BETWEEN 3 . 00.80 4 . 60.746 .0.69 7 .0.84 6 2 .7 1 0.87 0.779 .0.72 0.671 0 0.71 0.67 F I X T U R E2 S 3 0.80 0.71 0.64 0.58 0.76 0.68 0.62 0.57 0.64 0.58 4 0.74 0.63 0.56 0.50 0.70 0.61 0.55 0.49 0.57 0.51 5 0.68 0.57 0.49 0.43 0.65 0.55 0.47 0.42 0.51 0.45 6 0.62 0.50 0.43 0.37 0.59 0.49 0.42 0.36 0.46 0.39 7 0.57 0.45 0.37 0.32 0.54 0.43 0.36 0.31 0.41 0.34 8 0.52 0.40 0.32 0.27 0.50 0.39 0.32 0.27 0.36 0.30 9 0.48 0.36 0.28 0.23 0.46 0.35 0.28 0.23 0.32 0.26 10 0.44 0.32 0.25 0.20 0.42 0.31 0.24 0.20 0.29 0.23 Metric REFLECTANCES: 2200 45 2600 50 50 30 30 10 50 0.85 0.85 0.852 00.79 4.6 167.4 0.74 0.72 0.70 0.69 .7 0.66 0.631 30.60 0.61 0.59 0.55 0.51 0.55 0.53 0.48 0.45 0.50 0.48 0.43 0.39 0.45 0.43 0.37 0.33 0.40 0.38 0.32 0.28 0.36 0.34 0.29 0.25 0.32 0.30 0.25 0.21 0.29 0.27 0.22 0.18 0.26 10 30 10 MET CUA POR 0.79 0.79 241.8 0.67 0.65 1 5 . 0.56 3 0.59 0.51 0.48 0.46 0.42 0.40 0.37 0.35 0.32 0.31 0.27 0.27 0.24 0.24 0.20 0.21 0.17 MET LUM S 1.82 w = .3 fc = .2 SC = 1.7 60 50 RCR = 1 40 30 FT. BETWEEN FIXTURES RCR = 3 15 20 1400 1000 600 200 10 25 30 2200 1800 40 35 2600 45 50 QUICK CALCULATOR: Use this chart to determine the number and spacing of Ruud 16' Prismatic Reflector lights with 36,000 lumen, phosphor-coated 400W PSMH lamp and socket in MEDIUM distribution position. Determine number and spacing for other wattages by using these multipliers: Beta 250W PSMH 0.57 400W PSMH* 1.17 REFLECTANCES: 80 cc = .5 w = .3 Initial Footcandles 100 100 fc = .2 90 REFLECTANCES: 80 cc = .5 w = .3 90 70 © 2012 Ruud Lighting, Inc. – A Cree Company. All rights reserved. The information in this document is subject to change without notice. 70 Initial Footcandles Initial Footcandles 0.92 0.75 10.63 2.2 0.54 0.47 0.40 0.35 0.30 0.26 0.22 0.19 cc = .5 70 SQ. FT. PER 0 FIXTURE 90 SC = 1.8 80 60 50 70 50 60 40 REFLECTANCES: = .5 40 30 Advanced Lighting Technologies Australia Inc 20 Advanced Lighting Technologies New Zealand Ltd RCR = 3 10 Advanced Lighting Technologies Asia Pte Ltd 200 600 1000 1400 SC = 1.7 50 30 110 Lewis Road, Wantirna South, VIC 3152 40 20 8 Boeing Place, Mount Maunganui RCR 30 10 Block 4008, Ang Mo Kio Avenue 10, #04-06, Techplace 1 1800 2200 2600 S Q . F T. P E R 0RE 0 F I X2 TU F T. 1B0E T W E E N FIXTURES 200 Australia RCR = New Zealand Singapore = 3 6 0= 0 3 RCR 1000 1 ® Rev. 07/05/12 An Advanced Lighting Technologies Company 61 03 9800 5600 64 07 579 0163 65 6844 2338 1400 fc = .2 SC = 1.8 fc = .2 w = .3 cc 9201 Washington Avenue • Racine, Wisconsin 53406-3772 • PHONE: (800) 236-7000 • FAX: (800) 236-7500 www.ruudlightingdirect.com RCR = 1 RCR• =WEB: 1 60 F T. B E T W E E N FIXTURES 10 90 80 100 S Q . F T. P E R 0 FIXTURE RCR = 1 431 10 Beta 0.582 Cd/sq. m 73528 33301 16713 14531 = 16728 .2 SC = 1.7 646 20 QUICK CALCULATOR: Use this chart to determine the number and spacing of Ruud 16' Prismatic Reflector lights with 27,500 lumen, clear 250W HPS lamp and socket in WIDE distribution position. Determine number and spacing for other wattages by using these multipliers: 150W HPS fc % Fixture 18.51 36.23 66.99 82.98 46.74 15.98 17.02 100.00 100 SC = 1.8 30° RCR = 1 50 cc = .5 753 8000 90 12000 REFLECTANCES: 861 607 1907 3543 5802 6389 3677 1954 1604 1674 1651 1423 1066 658 366 253 130 22 2 Effective Floor Cavity Reflectance = 0.20 100 80 Angle 45° 55° 65° 75° 85° = .3 w 30˚ Coefficients of Utilization 70 10 10500 969 Efficiency = 90.9%; SC = 1.7; S/MH = 2.0 Effective 2 1 5Floor Cavity Reflectance = 0.20 CC 1 0 8 80 WALL 50 30 070 18.6 RCR METE RS BETWEEN 0 4 . 1.04 6 0 1.043 .1.04 FIXTURES 1 0.96 0.92 0.89 2 0.89 0.82 0.77 3 0.81 0.73 0.66 4 0.75 0.65 0.58 5 0.69 0.58 0.51 6 0.63 0.52 0.44 7 0.57 0.45 0.38 4000 8 0.52 0.40 0.33 9 0.48 0.36 0.28 10 0.43 0.31 0.24 7000 0˚ Lumens Zonal Lumens and Percentages Zone Lumens % Lamp 0-30 6056 16.82 0-40 11858 32.94 0-60 21924 60.90 0-90 27155 75.43 40-90 15297 42.49 60-90 5231 14.53 90-180 5571 15.48 0-180 32727 90.91 60˚ 1076 431 SQ. M PER FIXTURE 3500 % Fixture 16.72 37.32 75.58 84.87 47.55 9.29 15.13 30° 100.00 Coefficients of Utilization 323 RCR = 3 120˚ 150 90° International Catalog RCR = 1 538 180 Initial Footcandles Initial Footcandles 1076 Candlepower Summary Angle Mean CP 0 6213 5 6343 15 6664 25 7541 35 9389 45 8643 55 3872 65 1863 75 1500 85 1537 95 1524 105 1352 115 1081 125 729 135 455 145 404 155 288 165 53 175 20 180 14 Lamp: 400 Watt (Clear) – 36,000 lumens Lens: None Socket Position: Medium Test Distance: 26' (8 m) Initial Lux 4000 Pulse Start Metal Halide Candlepower Summary Angle Mean CP Lumens 0 5116 5 4781 455 15 4181 1219 25 5337 2485 35 8201 5120 45 8967 6593 55 2780 2920 65 868 897 75 613 120° 670 85 673 742 95 760 812 105 741 770 115 589 590 125 517 477 135 698 528 145 771 459 155 212 122 4000 165 9 3 175 4 0 180 3 Lamp: 250 Watt (Clear) – 27,500 lumens Lens: None Socket Position: Wide Test Distance: 26' (8 m) Certified Test Report: Lighting Sciences Inc. No. LSI 7628 1800 www.adlt.com.au www.adlt.co.nz www.adlt.com.sg 2200 2600