DIRECT MOUNT GWC0-16 SERIES 16" FULL CUTOFF WALL PACK Lens Assembly Rigid die-cast copper-free aluminum and flat glass lens 6.5" (165 mm) Pivoting Hinges Ballast + Wiring Compartment 3.4" (86 mm) + + 16.9" (429 mm) 17.6" (447 mm) Capacitor 16.3" (414 mm) Lampholder Housing Die-Cast Aluminum DeltaGuard® finish Lamp (Included) Notes Reflector Precision semi-specular aluminum 10.3" (261 mm) SPEC # SPEC # SPEC # SPEC # SPEC # SPEC # SPEC # SPEC # SPEC # WATTAGE CATALOG # PULSE START METAL HALIDE 150W PSMH GWC0615-(a)(b) 250W PSMH GWC0625-(a)(b) 320W PSMH GWC0632-(a)(b) 400W PSMH GWC0640-(a)(b) HIGH PRESSURE SODIUM 250W HPS GWC0525-(a)(b) 400W HPS GWC0540-(a)(b) COMPACT FLUORESCENT* 57W CFL GWC0257-(a)(b) 70W CFL GWC0270-(a)(b) (a) VOLTAGE SUFFIX KEY M T U (b) OPTIONS (factory-installed) 120/208/240/277V (Standard) 120/277/347V (Canada Only) 120-277V Universal Voltage -(a)F -(a)P Q (CFL only) (Standard) 1 2 27 3 4 5 6 120V 277V 277V Reactor (PSMH Only) 208V 240V 480V 347V (Canada Only) Fusing Button Photocell Quartz Standby (includes 100W quartz lamp) (N/A on 277V Reactor) Specify (a) Single Voltage — See Voltage Suffix Key Consult factory for IP65 option. For voltage availability outside the US and Canada, see Bulletin TD-9 or contact your Ruud Lighting authorized International Distributor. Specify (a) Voltage & (b) Options. *Consult factory for alternate lamp wattages. Reduced envelope ED28 lamp. GENERAL DESCRIPTION ELECTRICAL FINISH Full Cutoff Wall Pack fixture for HID lamp, totally enclosed. Housing is seamless copper-free die-cast aluminum. Lens assembly consists of a hinged, rigid die-cast copper-free aluminum frame and clear borosilicate glass lens held securely inside. Lens frame is easily removable and allows for easy attachment and serviceability using top pivoting hinge. Complete silicone gasketing around lens and gasketing at mounting provide a watertight seal. Ballast compartment is separate, and gasketed, from the optical chamber. A precision specular aluminum reflector provides forward throw with wide distribution to ensure wide fixture spacings and maximum light levels. Fixture design provides excellent IES Full Cutoff light distribution without glare. The optical chamber is sealed to reduce dirt and insect contamination. Furnished with e-coated, copper-free, lightweight mounting box designed for installation over standard 4-inch square or octagonal and single-gang J boxes and for conduit entry from top, sides and rear. Designed and approved for easy through-wiring. All PSMH and MH fixtures use vertical-lamp position. All HPS and CFL fixtures use horizontal-lamp position. Fixture includes a clear, mogul-base lamp. 320 – 400W PSMH utilize the ED28 reduced envelope lamp. Pulse-rated porcelain enclosed, 4kv-rated screw-shell-type lampholder with spring-loaded center contact and lamp locking feature. Fluorescent fixture includes one 57 or 70W quad tube/4-pin compact fluorescent lamp. Fixtures require a minimum 90°C temperature feed wire. All ballast assemblies are highpower factor and use the following circuit type: Exclusive Colorfast DeltaGuard® finish features an E-coat epoxy primer with medium bronze ultra-durable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. The finish is covered by our seven-year limited warranty. PATENTS 6,867,959; 7,354,177; D577,146; Patents Pending. 277V Reactor 150 – 400W PSMH ACCESSORIES HX — High Reactance 150W PSMH WM-GW Uneven Surface Mounting Plate EFBP2-D13 Emergency Egress (57W CFL only – remote mounted) CWA — Constant Wattage Autotransformer 250 – 400W PSMH; 250 – 400W HPS; 150W PSMH – 480V Electronic (120 – 277V Universal Voltage) (minimum starting temperature 0˚F [-18˚C]) 57 and 70W CFL LABELS ANSI lamp wattage label supplied, visible during relamping. UL Listed in the US and Canada for wet locations. © 2011 Ruud Lighting, Inc. – A Cree Company. All rights reserved. The information in this document is subject to change without notice. ® 9201 Washington Avenue • Racine, Wisconsin 53406-3772 • PHONE: (800) 236-7000 • FAX: (800) 236-7500 • WEB: www.ruudlightingdirect.com Rev. 05/02/12 An Advanced Lighting Technologies Company Advanced Lighting Technologies Australia Inc Advanced Lighting Technologies New Zealand Ltd Advanced Lighting Technologies Asia Pte Ltd 110 Lewis Road, Wantirna South, VIC 3152 8 Boeing Place, Mount Maunganui Block 4008, Ang Mo Kio Avenue 10, #04-06, Techplace 1 Australia New Zealand Singapore 61 03 9800 5600 64 07 579 0163 65 6844 2338 www.adlt.com.au www.adlt.co.nz www.adlt.com.sg DIRECT MOUNT GWC0-16 SERIES 16" FULL CUTOFF WALL PACK Isofootcandle plots show initial footcandles at grade. (Footcandles ÷ 0.0929 = Lux) 180° 120° 150° 80' 80' 60' 40' 20' 0 20' 40' 60' 60' 18.3 90° 0.3 0.5 40' 3 20' 5 0' 24.4 30° Candlepower distribution curve of 400W PSMH Full Cutoff Wall Pack. 6.1 10 60° 15536 20715 12.2 1 5179 10357 80' 24.4 18.3 12.2 6.1 0m 6.1 12.2 18.3 0m 24.4 Isofootcandle plot of one 400W PSMH Full Cutoff Wall Pack at 20' (6.1 m) mounting height. ® © 2011 Ruud Lighting, Inc. – A Cree Company. All rights reserved. The information in this document is subject to change without notice. 9201 Washington Avenue • Racine, Wisconsin 53406-3772 • PHONE: (800) 236-7000 • FAX: (800) 236-7500 • WEB: www.ruudlightingdirect.com Rev. 05/02/12 An Advanced Lighting Technologies Company Advanced Lighting Technologies Australia Inc Advanced Lighting Technologies New Zealand Ltd Advanced Lighting Technologies Asia Pte Ltd 110 Lewis Road, Wantirna South, VIC 3152 8 Boeing Place, Mount Maunganui Block 4008, Ang Mo Kio Avenue 10, #04-06, Techplace 1 Australia New Zealand Singapore 61 03 9800 5600 64 07 579 0163 65 6844 2338 www.adlt.com.au www.adlt.co.nz www.adlt.com.sg