For many years, operators have expressed the industry’s need for multiphase flow meters, since flow measurement is at the core of all surface testing applications. Accurate metering of the well stream is a critical deliverable by which the success of a well test can be quantified.
Just as well testing has evolved, so has Halliburton. To offer a full range of benefits, Halliburton has expanded its testing capabilities to provide reliable products and services focused on the acquisition and analysis of dynamic reservoir information and reservoir optimization solutions.
Halliburton offers the ideal self-sufficient Multiphase Flow Meter and, which features the industry’s only non-radioactive technology that provides users with unsurpassed versatility, range, and accuracy with the capability of measuring flow rates and phase fractions covering the entire range. The technology can be deployed as a permanent installation or trailer-mounted solution combined with a bypass/choke manifold where verification of pure phase densities can be obtained.
All options provide a compact metering solution, which is simply integrated into all applications.
The system has two integrated meter sizes in a single skid, which provides a compact metering solution with an unequalled turndown ratio of 100 that surpasses all conventional MPFM technology in today’s market. The technology encompasses standard sensors that are easily configured to accommodate all Multiphase/Wetgas applications.
The pressure, pressure differentials, and temperature frequency signals are used in a high-frequency transient analysis – a multiphase mathematical solution that outputs accurate flow rates of oil, water, and gas instantaneously without offline calculations or adjustments.
This can be viewed at site or remotely utilizing Halliburton’s InSite
Anywhere®, which allows access to flow measurement data from anywhere in the world.
The MPFM has compact sensors that are easily configured in a variety of ways, the uniqueness of this completely self-sufficient unit resides in its ability to cover all flow regimes and range accurately. The MPFM functions with built-in redundancy and is combined in two parallel real-time measuring units with different bore sizes handling the industry’s lowest and highest applications, which enables extended flow rate coverage for operators with a single unit.
MPFM technology enables the user to control and optimize accuracy in real time, ensuring the reliability of data.
Halliburton’s Mobile Multiphase Flow Meter
Surface Data Acquisition system
TESTING AND SUBSEA
Applications
• Offshore and land exploration, appraisal, and production testing
• Well cleanup optimization
• Production and fiscal allocation
• Production trending
• Artificial lift optimization
• Flow rate measurement in unfavorable environments
• Early production facility (EPF)
Features
• Exceptional dynamic response time
• Industries largest operating envelope
• No separation required
• 100% gas void fraction (GVF) capability
• No moving parts
• Compact and robust design
• Qualified and covers all environments
Technical Specifications
Multiphase Flow Meter
Nominal ID
Part Number (In accordance DNV 2.7-3)
Part Number (Type Approved DNV 2.7-3)
Material of Construction
Working Pressure psi (Mpa)
Temperature Class °C (°F)
Service
Water/Liquid Ratio (WLR)
Gas Volume Fraction (GVF)
Instrumentation Temperature °C (°F)
Power Consumption (W)
Dimensions (H x W x D) M
Weight (Kg)
Connections (Inlet – Outlet)
Flow Measurement Capability
Liquid Flow Rate (No Gas) BPD
Gas Flow Rate (No liquid) MMSCFD
Repeatability (Mass flow rate actual)
Resolution (Mass flow rate actual)
Optional
Hazardous Area Classification
Ingress Protection
Communication Protocol
Data Connectivity
Process Connections
1”
Available on request
Available on request
Inconel ® 625
5,000 (35.5)
150 (302)
H²S
0 – 100%
0 – 100%
-20~80 (-40~176)
35
Available on request
Available on request
Available on request
125 ~ 1,250
0.64 ~ 9
Better than ±1%
Better than ±1%
Benefits
• Superior response time
• Improved well diagnostic information
• Reduction in chemicals and testing duration
• Increased reservoir management
• No pressure, volume, and temperature,
(PVT)
• No radioactive source
• Multiphase and wet gas capability
• Easy to maintain
Multiphase Flow Meter Models
2”& 4”
Available on request
Available on request
Inconel ® 625
5,000 (35.5)
150 (302)
H²S
0 – 100%
0 – 100%
-20~80 (-40~176)
35
2.9 x 2.0 x 2.2
2.600
4 1/16”
3”& 6”
Available on request
Available on request
Inconel ® 625
5,000 (35.5)
150 (302)
H²S
0 – 100%
0 – 100%
-20~80 (-40~176)
35
4.0 x 2.3 x 3.0
3000
4 1/16”
200 ~ 25,000
0.3 ~ 37
Better than ±1%
Better than ±1%
500 ~ 50,000
1.2 ~ 122.3
Better than ±1%
Better than ±1%
FM, CSA and ATEX Explosion Proof ~ Class 1, Div 1, Group B, C & D ~ T1 & T5
Nema 4X, IP66
MODBUS® RT U RS485
RS-485 or Ethernet TCP/IP (MODBUS®)
Grayloc® Weld neck, ANSI flange, API Flange
5”
Available on request
Available on request
Inconel ® 625
5,000 (35.5)
150 (302)
H²S
0 – 100%
0 – 100%
-20~80 (-40~176)
35
3.2 x 2.0 x 1.8
2.5
5” Grayloc®
3800 ~ 38,000
8.0 ~ 80
Better than ±1%
Better than ±1%
For more information about Halliburton’s Multiphase flow meter technology, please call your local Halliburton representative or e-mail us at welltesting@halliburton.com.