stelmec® P RODU S PO ER boundaries CT W beyond Pole Mounted Sectionalizer is dedicated to serve the purpose of disconnecting the faulty section SSSG12 automatically in conjunction with an upstream Autorecloser circuit breaker in the substation and restoring power to the healthy lines/branches with minimum down time. OUTDOOR SF6 GAS INSULATED SECTIONALIZER Salient Features Compact in size, light weight design, hence easy to install and transport SF6 gas filled hermetically sealed stainless steel tank Control Unit with logic based programming Suitable for mounting on a single pole or on double pole structure Latest technology of arc quenching & short arcing time Local & Remote control options Manual & automated options Least maintenance Application Sectionalizer is installed in different branch/line in a power distribution system especially in ring main type distribution system. It has been observed that about 70% of faults in power distribution system are Transient Faults (i.e. short-time faults) which get cleared within mille-seconds. The upstream Autorecloser, through a number reclosing operations with a definite interval of times determines the type of the fault (transient or permanent) and in case of permanent faults, the faulty section is isolated by Sectionalizer and power is restored to the healthy branches of the distribution system with a minimum time lag. OUTDOOR SF6 GAS INSULATED SECTIONALIZER SSSG12 SIPV 12 - 12KV PANELS Technical Specifications ® Technical Specifications Description SSSG 12-16 Description SSSG 12-16 Rated voltage 12 kV Mounting on Single/Double pole Rated normal current 630 A Rated frequency 50Hz Rated short-time withstand 16 kA, 3s current & duration Rated short-circuit making 40 kA structure Fault break capacity 630 A Operating mechanism Solenoid Degree of protection of gas tank IP67 Material of bushing Cycloaliphatic epoxy current (peak) resin Rated power frequency 28 kV withstand voltage (one minute) Rated lightning impulse 75 kVp voltage (peak) Number of phase 3 Method of earthing Solid Interrupting medium SF6 Gas Insulating medium SF6 Gas Type Outdoor Mechanical endurance class M2 SF6 rated pressure 0.14 MPa Leakage rate per year <0.02% Weight (without structure) 80 kg (Approx.) Dimensions (W x D x H) 1260mm x 760mm x 525mm Reference Standard IEC 62271-103 Control Unit Power supply to operate the Sectionalizer Multifunction meter to monitor – line current, line voltage, PF, fault & its type, duration of fault and other related data w.r.t. real time and transmit the same through its RS485 port MODBUS to the PLC on the control unit. PLC with its sufficient memory stores these data and at the same time sends these data to the communication protocol Communication Every Control Unit is having a communication Modem (leased line / GPRS / 3G/GSM/Fibre Optic); hence they are connected to each other and also with auto-recloser and with the integrated SCADA (installed at substation) based on standard communication Protocol IEC-60870-5-104. Moreover, there will be dedicated RS-232C serial port capable of communicating (over IEC-60870-5-101). Backup Every control unit is equipped with rechargeable dry battery of adequate power delivering capacity & along with battery charger. There is a continuous effort at Stelmec to keep abreast of latest technology inline with customers’ requirement. All these activities are followed as per ISO 9001 : 2008. stelmec beyond boundaries ® SBU – II (Medium Voltage Switchgear Division) CORPORATE Plot no. 90/91/92, Virar-Vajreshwari Road, Usgaon, Vasai (E), Dist. Palghar – 401 303. Tel: +91 250 – 6456432 / 33 / 34 Stelmec Limited 'Sea Queen', 43-A, H.K. Bhabha Road, Bandstand, Bandra (W), Mumbai - 400 050. E-mail: corporate@stelmec.com Tel: +91 22 2643 6127 / 28 / 29 | Fax: +91 22 2643 6139 website: www.stelmec.com