7777 Hollister Road Houston, Texas 77040 · Phone

advertisement
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
L o u v e r s
·
V e n t i l a t o r s
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
W. Little York
Hollister
7777 Hollister
·
W. Tidwell
290
Beltway 8
Sam Houston Parkway
Hollister
Bingle
45
59
W. Little York
Tidwell
Clay
290
43RD
610
10
10
59
610
45
7777 Hollister, Houston, Texas 77040 • Phone: 713.856.9696 • Fax: 713.856.9686 • 1.800.356.7746 • Email: info@mpvent.com • www.mpvent.com
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
CONTINUOUS VENTILATORS …
…used on metal roofing systems roofs conform to MP’s high standards and specifications which have been
developed, tested and proven over many years. They provide an excellent value for the user.
Standard Size
Bird Screen
9" throat and 12" throat— 10 foot sections. Other sizes
available upon request. Low profile design can be used for
single unit or continuous run installation with no disassembly.
Fully protected by 4 x 4 mesh galvanized hardware cloth.
Integral Dampers
Easy-moving damper opens to any degree from fully open
to completely closed.
Design
Aerodynamically proportioned to exclude weather — protects air passages and full outlet area.
Construction
Durable 26 gauge exterior combined with internal components of 24, 20 and 18 gauge die formed sheet metal and
machined parts for long service life.
Finish
Pre-painted or galvalume is standard. Other materials and
finishes available upon request.
Drainage Area
Continuous slot — bottom of both sides of windbands.
BUILDINGS MUST BREATHE!
Ventilators manufactured by Metallic Products are in accordance with the highest design requirements and specifications.
25 years plus of experience in furnishing stationary, gravityflow, continuous ridge ventilators has proven their efficient
performance and lasting quality.
A properly engineered ventilation system using continuous
ridge ventilators will control the movement of fresh air through
the building removing hot, stale air and air contaminated by
manufacturing or production processes. Summer heat is released
naturally through gravity ridge ventilators. During winter proper
ventilation can assist in the control of condensation and other
moisture problems, such as rust and deterioration of insulation or
the damage to stored products.
The Metallic Products’s ridge ventilator is a manufactured
in 10-foot lengths which can be installed as individual units or in
continuous runs. Vents may be furnished with or without dampers
to control the flow of air. Operation of dampers is standard by pull
chains (Please specify when ordering), multiple damper operation
is available for up to 5 or more units.
Ventilators are shipped with a 1:12 end cap and can be field
modified to accommodate up to a 6:12 roof pitch.
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
CV-01 / Rev. 8/01
DIMENSIONS AND TECHNICAL DATA
B
A
BIRD SCREEN
DIE-FORMED BAFFLE
DIMENSIONS (In Inches)
RAIN SHIELD
Throat*
A
9
*12
13
17
DAMPER
LIFTER ARM
C
SADDLE STRAP
B
C
211⁄4 141⁄2
281⁄2 18
D
E
18
22
281⁄4
33
SHIPPING WEIGHTS
SIDE SKIRT
THROAT
Size
Boxed
9"
12"
124 lbs
148 lbs
Standard
Pkg. Size
Crated
209 lbs 1241⁄2" X 191⁄2" X 301⁄2"
218 lbs
1241⁄2" X 23" X 35"
D
* Other sizes available upon request.
E
TURNBUCKLE
PULL BAR
END CAP OF VENT END CAP OF VENT
END CAP OF VENT
POP RIVET END
CAP TO DRAIN
ASSEMBLY
STOVE BOLT
DRAIN AT MULTIUNIT SPLICE
PULL BAR CONNECTION:
Install turnbuckles between
adjacent pull bars. With the
dampers in the closed position,
adjust turnbuckles starting at
one end of the run.
DRAIN AT CAP
OF END VENT
ROOF PANEL MAJOR RIB
NOTE:
BREAK DRAIN ASSEMBLY TO
FOLLOW EXACT ROOF SLOPE.
ROOF PANEL MAJOR RIB
RAIN SHIELD
DAMPER
END CAP
RAIN SHIELD
DAMPER
END CAP
PIVOT BRACKET & SADDLE STRAP
PULL BAR
PULLEY AT FRAME OR WALL
LIFTER ARM
GUIDE ROD
SPRING
PIVOT BRACKET &
SADDLE STRAP
PULL BAR
LIFTER ARM
GUIDE ROD
SPRING
CHAIN CATCH (OPT.)
CHAIN WITH HANDLE
2" TRAVEL
PULL BAR IN CLOSED POSITION
TO CLOSE DAMPER, PULL CABLE
OPTIONAL PULL CHAIN OPERATION
PULL CHAIN MUST BE
REMOVED FOR CONTINUOUS
RUN OPERATION
(SINGLE UNITS ONLY)
STANDARD CABLE OPERATION
Chain-operated damper utilizes a rugged sash chain through chain locking device. Damper is spring-loaded to open and can
be adjusted to any opening from fully open to fully closed. Optional operator packages for multiple units or wall operation are
available. (See below.)
PERFORMANCE DATA
Throat Size
9"
Vent Above Ground
10'
20'
30'
40'
CFM
1323
1890
2241
2511
10'
1764
20'
2520
12"
30'
2988
40'
3348
Assumes 10° Temperature differential and 5 mph wind speed
COLUMN
PIVOT
ANGLE
LEVER
HANDLE
CLAMP
EYEBOLT
s
PLATE WELDED
TO COLUMN
‘S’ HOOK
BOAT WINCH
GIRT
FOR CONTINUOUS RUNS
UP TO 5 UNITS
FOR CONTINUOUS RUNS
UP TO 10 UNITS
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
9" CONTINUOUS VENTILATOR SPECIFICATIONS
Ventilators are of low profile design to provide gravity type ventilation.
Birdscreen is provided to prevent nesting and each unit contains flashing for either
single unit or continuous-run installation.
Each unit is 9" x 10' with a base ventilating capacity of 2700 CFM at 20°
temperature differential with a 25' stack height.
Exterior parts are 26GA. G90 galvanized, painted galvanized or galvalume.
ASTMA446.
Interior parts are all of G90 galvanized steel.
Substructure consists of 10GA. saddle straps with interior baffles of 24GA.
Pull bars and pivot brackets are of 20GA. Lifter arms and damper slides are of
18GA.
Manual operation is through activation of pull bar, which is attached to bellcranked type lifter arms connected to damper with teflon coated pins through
damper slides.
Dampers are spring loaded to remain in open position until pull bar is
operated and locked in the closed position. Dampers operate in vertical manner.
Birdscreen is 4x4 mesh galvanized hardware cloth.
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
CV-01.1 / Rev. 8/01
B
A
C
THROAT
D
E
DIMENSIONS (In Inches)
Throat
A
B
C
D
E
4
61⁄4
121⁄2
9
10
18
9
13
211⁄4
141⁄2
18
281⁄4
12
17
281⁄2
18
22
33
18
263⁄4
455⁄8
305⁄8
30
49
24
331⁄2
57
383⁄8
361⁄8
581⁄8
36
471⁄2
811⁄4
535⁄8
55
831⁄2
SHIPPING WEIGHTS
Size
Boxed
Standard Crated
Pkg. Size
9"
124 lbs
209 lbs
1241⁄2" X 191⁄2" X 301⁄2"
12"
148 lbs
218 lbs
1241⁄2" X 23" X 35"
DATE:
8/18/994/22/97
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-04 / Rev. 00/00
CV-01.2 / Rev. 8/99
FLAT SKIRT
DIMENSIONS
APPLICATION
PART:
RIDGE VENT
CONTINUOUS
VENT
VS-1
WELDED FRAME RIDGE VENTILATORS
B
E
SIDE
F
BIRD SCREEN
EXTERIOR FRAME
D
J
RAIN SHIELD
M
INTERIOR FRAME
SADDLE STRAP
G
C
L
SKIRT
K
H
A (THROAT)
P
N
NOTE: EXTERIOR AND INTERIOR FRAME MADE OF 1⁄8" X 1 1⁄2" X 1 1⁄2" ANGLE HOT-DIPPED GALVANIZED AFTER
WELDING. ALL OTHER PARTS MADE OF 22 GA. SHEET METAL, STANDARD WHITE OR GALVALUME.
WELDED FRAME VENTILATOR DIMENSIONS
A
A/2
B
C
D
E
F
G
H
J
K
L
M
N
P
15
71⁄2
39
261⁄2
8
223⁄4
113⁄8
113⁄8
97⁄8
5
61⁄2
71⁄2
167⁄8
8
25
18
9
455⁄8
305⁄8
105⁄8
263⁄4
133⁄8
133⁄8
11
57⁄8
81⁄4
9
185⁄8
91⁄2
30
20
10
49
325⁄8
101⁄4
283⁄4
143⁄8
143⁄8
113⁄8
8
91⁄8
10
173⁄4
9
33
24
12
57
383⁄8
117⁄8
331⁄2
163⁄4
163⁄4
135⁄8
81⁄8
91⁄4
12
211⁄2
11
361⁄8
30
15
701⁄8
459⁄16
143⁄8
41
201⁄2
201⁄2
14
91⁄2
115⁄8
16
265⁄8
113⁄8
491⁄4
36
18
811⁄4
535⁄8
167⁄8
471⁄2
233⁄4
233⁄4
191⁄2
123⁄8
121⁄2
18
261⁄2
141⁄4
55
42
21
94
61
187⁄8
56
2613⁄16
265⁄16
221⁄2
141⁄2
139⁄16
21
311⁄4
165⁄8
62
48
24
106
657⁄8
191⁄4
671⁄4
271⁄4
271⁄4
267⁄8
167⁄8
135⁄16
24
341⁄8
201⁄8
671⁄2
DATE:
TITLE:
Purlin Spacing = “P” Plus 3" Each Side
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-04 / Rev. 00/00
CV-01.3 / Rev. 9/99
PART:
WT.
275#
324#
428#
550#
4/22/97
9/20/99
FLAT SKIRT
DIMENSIONS
APPLICATION
WELDED
RIDGE FRAME
VENT
CONTINUOUS VENT
Table of Capacities for Continuous Ventilators
MP
CAPACITY:
To determine capacity per unit, multiply “Base Rating” by “Temperature-Height Factor”: CFM = Base x
Temperature-Height Factor
Based on fresh air intake area 11/2 times ventilator throat area. Assumes 5 mph wind speed.
Temperature-Height Factors
Temperature Difference
Height
10'
15'
20'
25'
30'
35'
40'
45'
50'
55'
60'
65'
70'
75'
80'
5°
.37
.42
.53
.58
.63
.66
.70
.74
.77
.80
.83
.85
.88
.90
.93
10°
.49
.60
.70
.77
.83
.87
.93
.96
1.01
1.06
1.09
1.12
1.17
1.19
1.22
15°
.58
.71
.81
.89
.97
1.02
1.08
1.12
1.18
1.23
1.28
1.32
1.36
1.39
1.42
20°
.64
.80
.92
1.00
1.08
1.14
1.22
1.28
1.33
1.39
1.44
1.48
1.53
1.57
1.61
25°
.70
.86
.99
1.08
1.17
1.24
1.30
1.38
1.44
1.50
1.55
1.61
1.67
1.69
1.72
Base Ratings
30°
.76
.92
1.07
1.18
1.28
1.35
1.41
1.48
1.56
1.64
1.69
1.74
1.79
1.83
1.86
35°
.81
.99
1.14
1.25
1.36
1.44
1.50
1.59
1.67
1.72
1.79
1.85
1.89
1.96
2.00
40°
.86
1.05
1.22
1.33
1.45
1.51
1.61
1.68
1.75
1.83
1.90
1.97
2.02
2.06
2.11
45°
.95
1.09
1.26
1.39
1.50
1.58
1.68
1.75
1.83
1.92
2.00
2.06
2.11
2.17
2.20
Size
4"
9"
12"
15"
18"
24"
30"
36"
42"
48"
C.F.M.
1200
2700
3600
4500
5400
7200
9000
10800
12600
14400
Height = vertical rise from inlets near floor to ventilator.
Temperature = estimated temperature difference between middle of air intake near the floor and ventilator with
dampers open.
CV-01.4 / Rev. 8/99
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
METALLIC PRODUCTS CONTINUOUS VENTILATOR
DESIGN EVALUATION AND CERTIFICATION
This is to certify that the construction of the Metallic Products 10ft. sections of ridge ventilators with 10
ga. Base Straps, 24 ga. Baffles, and 26 ga. Sides, Ends, Skirts and Dampers will withstand wind loads
of 100 MPH when adequately supported by the roof panel to which it is attached. Minimum required
attachment is No. 14 self tapping screw to the top of each major roof panel rib.
Wind load is determined in accordance with the MBMA Design Manual procedure. The following analysis
could be construed as Parts and Portions of the building structure, such as load supporting systems of
structural roof panels, purlins, bracing, and framing.
The typical installation procedure for vents is to fasten each side skirt to the roof panel with a minimum
of 1-#14 STS @ 12" o.c. (2 fasteners per linear foot of vent). Various Manufacturers test data has indicated
that the resistance of these fasteners exceeds the design values used by Metallic Products by a factor
in excess of 2 1/2 to 1. This design value is 50 lbs. pull out and 100 lbs. shear per fastener when installed
in 26 ga. galvanized panels of 50,000 psi minimum yield stress.
The probable extreme standard condition would be a roof with mean height of 60 ft. and a slope between
10 and 30 degrees (4/12 included).
1. Assume the clear distance at the ventilator between roof sheets to be 24" max. (This is probably
greater than would occur for a 12" throat vent.)
2. Assume total vent is in “Z” edge strip. Building would have to be at least 100 ft.wide and 25 ft.
high at the eave.
3. Velocity Pressure q = 30.4 PSF (100 MPH) (Table 5.2b in the MBMA Low Rise Building Systems
Manual)
4. Se @ Interior edge from figure 5.5c, with roof angle between 10 and 30 degrees = 2.1
5. Uplift Pressure = 30.4 x 2.1 = 63.84 PSF.
6. Reduce because it is due to wind = 63.84 x 3/4 = 47.88
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
CV-01.5/1 / Rev. 8/01
Page 2
METALLIC PRODUCTS CONTINUOUS VENTILATOR
DESIGN EVALUATION AND CERTIFICATION
12" Standard Throat Ventilator: The 24 inch ridge opening results in 2 x 47.88 = 95.76 lbs. per ft. uplift on
ventilator or 47.88 lbs per fastener which is less than the 50 lbs. per fastener design stress. The ventilator
is less than 2 ft. high resulting in a shear stress of less than 50 lbs./fastener from an equal horizontal wind
load.
The building design used to create this wind loading exceeds the dimensional parameters of most
standard buildings offered by Metal Building Manufacturers. The location of the vent at the very end of
the building ridge (within the “Z” edge strip) is not unusual when continuous vents are used for the full
building length. However, a more common arrangement is to place the vents, one in the center of each
bay or to begin the continous run, one ventilator back from the end wall peak.
Evaluation conducted by:_______________________________
John M. Reynolds, P.E.
CV-01.5/2 / Rev. 5/97
May 7, 1997
END CAP OF VENT
END CAP OF VENT
DRAIN AT MULTI-UNIT
SPLICE (WEEP)
DRAIN AT END OF VENT
CAULK HERE
POP RIVET END CAP TO
DRAIN ASSEMBLY
ROOF PANEL MAJOR RIB
CAULK HERE
ROOF PANEL MAJOR RIB
NOTE:
BREAK DRAIN ASSEMBLY TO FOLLOW
EXACT SLOPE OF ROOF
NOTES:
BE SURE WEEPS ARE LEFT OPEN
FOR 5:12 AND UP ROOF PITCHES,
THE TWO BOTTOM RIVETS MUST BE
REMOVED BEFORE END SKIRT MAY
BE PLACED ON VENT. REPLACE
RIVET WITH SCREW.
SIDE
SKIRT
RIDGE VENT FLASHING
WITHOUT DIE-FORMED SKIRTS
FASTENER
DATE:
CLOSURE WITH SEALANT T&B
END VIEW
CV-01.6/ Rev. 03/00
1/4/99
FLASHING
WITHOUT DIE-FORMED
SKIRTS
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
PART:
CONTINUOUS VENT
DRAWING #2
END SKIRT DETAIL AND
CONTINUOUS VENT SPLICE
CONTINUOUS VENTILATOR
DIE-FORMED SKIRT
CHANNEL SUPPORT
END CAP OF VENT
END CAP OF VENT
CHANNEL
GUTTER
TAPE SEAL
ROOF PANEL
GUTTER SUPPORT
END OF VENT DETAIL
DATE:
4/22/97
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-01.7 / Rev. 03/00
PART:
DIE-FORMED
SKIRT APPLICATION
CONTINUOUS VENT
VFSS-1
CONTINUOUS VENTILATOR
FLAT SKIRT
CLOSURE (Not by MP)
END OF VENT DETAIL
END CAP OF VENT
DRAIN AT END OF VENT
CAULK HERE
POP RIVET END
CAP TO DRAIN
ASSEMBLY
ROOF PANEL
MAJOR RIB
CLOSURE (Not by MP)
END SKIRT DETAIL AND
CONTINUOUS VENT SPLICE
END CAP OF VENT
DRAIN AT MULTI-UNIT SPLICE
DATE:
4/22/97
FLAT SKIRT
APPLICATION
CONTINUSOUS VENT
TITLE:
CAULK HERE
CV-01.8 / Rev. 03/00
ROOF PANEL
MAJOR RIB
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
PART:
BIRD SCREEN
END CAP
DAMPER GUIDE ROD
BAFFLE
RAIN SHIELD
DAMPER
BLIND RIVETS (2) REQ’D
FIELD CUT
FOAM CLOSURE
END SKIRT
DAMPER SLIDE
LIFTER ARM
SADDLE STRAP
PIVOT BRACKET
PEAK PANEL
6:12
5:12
4:12
3:12
2:12
SKIRT
OPERATOR BAR
END CAP DETAIL
THROAT
NOTE: DOTTED LINE INDICATES
FIELD CUT FOR 6:12 ROOF
SLOPE. OTHER SLOPES
AS NOTED.
ROOF PITCH LESS THAN 1:12 INSTALLATION:
INSTALL END SKIRT FOR 1:12 ROOF SLOPE AND FOAM CLOSURE WITH
TAPE SEALER TOP AND BOTTOM.
ROOF PITCH GREATER THAN 5:12 INSTALLATION:
REMOVE TWO BOTTOM RIVETS BEFORE INSTALLING END SKIRT.
REPLACE THE RIVETS WITH SHEETING SCREWS ONCE END SKIRT IS
IN PLACE.
RAIN SHIELD
DAMPER
END CAP
PIVOT BRACKET & SADDLE STRAP
PULL BAR
PULLEY AT FRAME OR END WALL
PUNCH MARKS
LIFTER ARM
GUIDE ROD
SPRING
2" TRAVEL
PULL BAR IN CLOSED POSITION
TO CLOSE DAMPER, PULL CABLE
STANDARD CABLE OPERATION
PULL BAR CONNECTION
DETAIL
RAIN SHIELD
DAMPER
END CAP
LIFTER ARM
GUIDE ROD
SPRING
PIVOT BRACKET &
SADDLE STRAP
PULL BAR
DATE:
CHAIN CATCH (OPT.)
CHAIN WITH HANDLE
OPTIONAL PULL CHAIN OPERATION
(SINGLE UNITS ONLY)
CV-01.9 / Rev. 03/00
1/04/99
TITLE:
PULL CHAIN MUST BE
REMOVED FOR CONTINUOUS
RUN OPERATION
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
PART:
INSTALLATION
DETAILS
FLAT SKIRT
CONTINUOUS VENT
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
CONTINUOUS VENT OPERATORS
DRAWING VEW-1
DETAIL 3 - TYPE A
OPERATOR #624 - HAND PULL-CABLE
35 ft. Plastic Coated Cable
2 Cable Clamps
I Chain Catch
2 Pulleys
DETAIL 3 - TYPE B
OPERATOR #634 - HAND PULL-CHAIN
35 ft. Chain
2 Pulleys
I Chain Catch
DETAIL 3 - TYPE C
OPERATOR #618 - LEVER TYPE
40 ft. Cable
2 Pulleys
2 Cable Clamps
I Lever Handle
Mounting & Installation Hardware
OPERATOR #616
1 Lever Handle Mounting Hardware
OPERATOR #619 - EXT.
50 ft. Cable
3 Eye Bolts
2 Cable Clamps
OPERATOR #634A
10 ft. Chain
I Pulley
I Chain Catch
OPERATOR #634B
4 ft. Chain
I Pulley
I Chain Hook
SINGLE UNIT OPERATOR FOR
MONOVENT
10 ft. Chain Installed
DETAIL 3 - TYPE D
OPERATOR #632 - BOAT WINCH TYPE
60 ft. Cable
2 Pulleys
I Boat Winch
Mounting & Installation Hardware
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
CV-01.10 / Rev. 8/01
DATE:
OPERATOR A: 3/16" UNCOATED AIRCRAFT CABLE WITH CABLE KEEPER
OPERATOR B: NO. 35 ZINC COATED SASH CHAIN WITH CHAIN KEEPER
OPERATOR C: HAND LEVER TYPE
OPERATOR D: BOAT WINCH TYPE
CV-01.11 / Rev. 10/83
3 UNITS MAX.
3 UNITS MAX.
6 UNITS MAX.
12 UNITS MAX.
OCT. 1, 1983
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
PART:
END WALL
INSTALLATION
CONTINUOUS VENT
VEW-1
OPERATOR A: 3/16" UNCOATED AIRCRAFT CABLE WITH CABLE KEEPER
OPERATOR B: NO. 35 ZINC COATED SASH CHAIN WITH CHAIN KEEPER
OPERATOR C: HAND LEVER TYPE
OPERATOR D: BOAT WINCH TYPE
CV-01.12 / Rev. 10/83
2 UNITS MAX.
2 UNITS MAX.
5 UNITS MAX.
10 UNITS MAX.
7777 Hollister Raod
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
DATE:
OCT. 1, 1983
TITLE:
SIDE WALL
INSTALLATION
CONTINUOUS VENT
VSW-1
PART:
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-01.13 / Rev. 10/83
WORM GEAR
ASSEMBLY
CONTINUOUS VENT
PART:
Hardwood Crating
60 – 9” x 10’ Vents Per Truck Load
(15 – 9” x 10’ Vents Per 10” of Trailer Space)
44 – 12” x 10’ Vents Per Truck Load
(11 –12” x 10’ Vents Per 10” of Trailer Space)
120 – 20” Round Vents with Peak Base Per Truck Load
(30 – 20” Round Vents Per 10” of Trailer Space)
48 – 20” Round Vents with Hillside Base Per Truck Load
(12 – 20” Round Vents Per 10” of Trailer Space)
Ridgeline Coravent
LOW PROFILE VENTILATORS
Prevent
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
LOW PROFILE FLOATING RIDGE VENT…
RIDGE LINE
...featuring Cor-A-Vent® ventilation core is designed specifically for architectural standing-seam retrofit applications and some residential applications where maximum ventilation is required in an attractive, very low-profile unit..
Standard Size
Construction
Each ten-foot unit features 180 square inches of free area
with a base rating of 450 CFM’s of air movement. Units in
lengths of other than ten feet can be manufactured upon
request. Throat size is determined by roof pitch.
Unit is factory assembled and ready for installation. Vent
features the Cor-A-Vent® ventilation core — a time-tested,
economical, self-cleaning and durable core which has
been in service since 1970. All steel parts are 24 gauge.
Design
Finish
Aerodynamic, low-profile design enhances the looks and
performance of architectural roof systems. The unit moves
toward the ridge on floating roofs. Vents are made to match
roof slope to maintain low-profile appearance.
Steel parts match roof type and color finish. All paint types
and colors are available including Kynar.® Please specify
roof system, paint system and color when ordering.
BUILDINGS MUST BREATHE!
One of the most overlooked components of design and
installation of architectural roofing systems, both in new construction and retrofit applications, is ventilation. A properly
engineered ventilation system using a continuous ridge vent in
conjunction with an under soffit intake will provide proper fresh
air movement through the roofing system removing hot, stale air.
Summer heat is released naturally, extending both the life and
performance of the roof. During winter proper ventilation can
assist in the control of condensation and other moisture problems
such as rust and insulation deterioration.
Ridge ventilators manufactured by Metallic Products are in
accordance with the highest design requirements and specifica-
tions. 25 years plus of experience in furnishing stationary,
gravity-flow, continuous ridge ventilators has proven their efficient performance and lasting quality.
Lo-profile floating ridge vents are a low-profile, aesthetically pleasing and extremely efficient means of ventilating
standing seam roofs. Each unit is manufactured in 10' lengths and
can be installed as a single unit or can be butted together to form
a continuous run. By lapping the furnished joint covers over the
top of the butted joints in a continuous run, the vent has the
appearance of a single unit.
When ordering please specify roof slope, roof system, paint
system, and color.
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SV-01 / Rev. 2/01
DIMENSIONS AND TECHNICAL DATA
Ventilation Core
Floating Ridge Cap
Ventilation Core
Skirt
12
1⁄2"
31⁄2"
Floating Ridge Cap
Existing Roof System
* ROOF SLOPE
3"
SECTION A
A
8 1⁄2"
Ventilation Core
5 1⁄2"
11⁄8"
1"
Skirt
2"
Existing Roof System
Closure Strip
THROAT
TABLE A
Air Movement per Lineal Foot Factors
Temperature Difference
HEIGHT
IN FEET
10
15
20
25
30
35
40
45
50
5°
16.65A
18.90A
23.85A
26.10A
28.35A
29.70A
31.50B
33.30B
34.65B
10°
22.05A
27.00A
31.50A
34.65A
37.35A
39.15B
41.85B
43.20B
45.45B
15°
26.10A
31.95A
36.45A
40.05A
43.65B
45.90B
48.60B
50.40B
53.10C
20°
28.80A
36.00A
41.40A
45.00B
48.60B
51.30B
54.90C
57.60C
59.85C
25°
31.50A
38.70A
44.50B
48.60B
52.65C
55.80C
58.50C
62.10C
64.80C
* NOTE: Throat Varies with Roof Slope
30°
34.20A
41.40B
48.15B
53.10C
57.60C
60.75C
63.45C
66.60C
70.20D
Note: If material is furnished by customer, the following
must be supplied for each 10' section:
Painted Screws
1 Sheet for Metal Roof, 2 for Shingle
15 Self-Tapping Screws 1⁄4" x 11⁄2"
Type A W/Washers
TABLE B
Wind Velocity Factors
Factors
WIND
M.P.H.
3
5
7
9
11
A
1.14
1.25
1.41
1.62
1.82
B
1.09
1.18
1.29
1.43
1.57
C
1.05
1.13
1.22
1.33
1.43
D
1.02
1.09
1.16
1.25
1.32
TOTAL CFM = (Table A) X (Table B) X Length
TABLE C
Throat Size (Determined by Roof Pitch)
Pitch
1:12
2:12
3:12
4:12
5:12
6:12
Throat Size
61⁄2"
61⁄8"
55⁄8"
51⁄4"
47⁄8"
45⁄8"
Pitch
7:12
8:12
9:12
10:12
11:12
12:12
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
Throat Size
41⁄8"
31⁄2"
3"
21⁄2"
21⁄8"
13⁄4"
NOTE:
DO NOT CUT ANY SLOTS IN THE EXISTING
DECK ONE TRUSS BAY EITHER SIDE OF A
DRAFT BARRIER WALL.
THROAT VARIES WITH ROOF PITCH
NOTE:
RIDGE VENT OPENINGS WILL REQUIRE
SPECIAL ATTENTION TO AVOID
INTERRUPTION OF ANY FIRE WALL
INTEGRITY
8 1/
2"
FLOATING RIDGE CAP
VENTILATION CORE
2"
8 1/
2"
5 1/2
"
1 1/8
"
6"
2"
SHINGLES
CUT SLOTS STAGGERED
EACH SIDE OF RIDGE BEAM
7 1/2" MIN.
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
SV-01.1 / Rev. 03/00
PART:
10/12/98
1:12 TO 5:12
PITCH
SHINGLE TYPE
CORAVENT
NOTE:
DO NOT CUT ANY SLOTS IN THE EXISTING
DECK ONE TRUSS BAY EITHER SIDE OF A
DRAFT BARRIER WALL.
NOTE:
RIDGE VENT OPENING WILL REQUIRE
SPECIAL ATTENTION TO AVOID
INTERRUPTION OF ANY FIRE WALL
INTEGRITY
THROAT VARIES WITH ROOF PITCH
10
1/2
"
FLOATING RIDGE CAP
VENTILATION CORE
2"
81
/2"
51
1 1/
8"
/2"
6"
2"
SHINGLES
CUT SLOTS STAGGERED
EACH SIDE OF RIDGE BEAM
7 1/2" MIN.
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
SV-01.2 / Rev. 3/00
PART:
10/12/98
6:12 TO 12 :12
PITCH
SHINGLE TYPE
CORAVENT
NOTE:
DO NOT CUT ANY SLOTS IN THE EXISTING
DECK ONE TRUSS BAY EITHER SIDE OF A
DRAFT BARRIER WALL.
NOTE:
RIDGE VENT OPENINGS WILL REQUIRE
SPECIAL ATTENTION TO AVOID
INTERRUPTION OF ANY FIRE WALL
INTEGRITY
10"
10"
FLOATING RIDGE CAP
2"
VENTILATION CORE
81
/2"
51
1 1/
8"
/2"
2"
SHINGLES
3 3/4" MIN.
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
SV-01.3 / Rev. 03/00
PART:
10/12/98
ROOF TO
WALL
SHINGLE TYPE
CORAVENT
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
PREVENT
…is one of our inVentive answers which features eave and ridge/hip components for an efficient, maintenancefree roof ventilation system.
Standard Size
Construction
Each section of PreVent comes in standard eight or tenfoot lengths. Custom lengths are available.
PreVent features Cobra® Ridge Vent material — a maintenance-free, lightweight, polyester composite product.
It will not dent, crack, or rust. Model R-24 is made from
24-gauge Galvalume® material. Models E-18 and E-16
are made of 18- and 16-gauge galvanized material,
respectively.
Design
All R-(ridge) series models are designed to work in conjunction with standard closures and ridge caps furnished by
your building or roof system supplier. The E-(eave) series
models are designed for eave venting and can be custom
formed to fit your application (Specify roof slope when
ordering.) All models feature a series of slots die cut the
entire length allowing 16.9 square inches of free area per
linear foot.
Advantages
Low cost. Ease of installation. No moving parts to wear out.
Energy efficient. Architecturally attractive. Adaptable to
many different roofing systems. No leaks. No snow infiltration. No bird nesting. No wind-driven rain infiltration. No
heat and moisture buildup in attics.
BUILDINGS MUST BREATHE!
One of the most overlooked components of design and
installation of roofing systems, both in new construction and
retrofit applications, is ventilation. A properly engineered ventilation system using a proper ridge vent in conjunction with an
under soffit intake will provide proper fresh air movement
through the roofing system removing hot, stale air. Summer heat
is released naturally, extending both the life and performance of
the roof. During winter proper ventilation can assist in the control
of condensation and other moisture problems such as rust and
insulation deterioration.
Ridge ventilators manufactured by Metallic Products are in
accordance with the highest design requirements and specifications. 35 years plus of experience in furnishing stationary,
gravity-flow, continuous ridge ventilators has proven their efficient performance and lasting quality.
PreVent ridge vents are a low-profile, aesthetically pleasing
and extremely efficient means of ventilating metal roofs. Each
unit is manufactured in 8 or 10' lengths and can be installed as a
single unit or can be butted together to form a continuous run,
creating the effect of a seamless design.
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SV-02 / Rev. 2/01
Dimensions and Applications
Ridge Cap
PreVent
Model R-24
PreVent
Model E-16
Roof Panel
Air Flow
Support Framing
Eave
Support
Air Flow
Closure
RETRO FIT ROOF APPLICATION
Ridge and Eave Vents
1⁄2"
Ridge Cap
13⁄32"
Air Flow
2"
ARCHITECTURAL RIDGE DETAIL
1 1 ⁄ 2"
11⁄2"
Cobra® Ridge Vent Material
VENTILATING SLOTS
Used on all models
Property
Test
Values
Air Permeability
ASTM D737
>>760 cu. ft. per minute
Tear and Tensile Strength
ASTM D1294-86 Tear: Machine 25 p.p.i.
Counter 25 p.p.i.
MODEL R-24
11⁄2"
ASTM D2261-83 Tensile: Machine 25 p.p.i.
Counter 25 p.p.i.
ASTM D1929
963° F.
LOREN C115
-25° F.
Snow Infiltration
CRL 5704
—0—
LA
S SI FI E
D
C
Cold Crack Resistance
BOCA
See BOCA Evaluation Services, Inc.
Research Report #93-49
Made from over
90% recycled fiber:
over 30% post-consumer content
Cobra® Ridge Vent Material
11⁄2"
Self-Ignition Temperature
1 ⁄2"
4"
Cobra® Ridge Vent Material Technical Data:
DADE COUNTY
Acceptance #94-0907.01
21⁄2"
31⁄2"
MODELS E-16 & E-18
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
Roof
Slope
Apex Ventilator
Round Ventilator
ROUND VENTILATORS
Turbine Ventilator
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
ROUND GRAVITY VENTILATORS
Standard Size
Bird Screen
Round gravity ventilators are available in standard 12,
20, and 24 - inch diameter throat sizes. Other sizes up
to 48 - inch available through special orders.
Assembly is completed by the installation of a 4 x 4 bird
screen in the opening between the inner band and the
rainshield to resist the entry of birds into the vent area.
Integral Dampers
Finish
The addition of a vertical-lift type damper completes the
weather-tightness of the unit. The damper is supported
in the open position by four strong springs and is closed
by a long pull chain. Damper may be locked in any
position by the use of an optional key type chain lock
(please specify when ordering.) Ventilator may be furnished without damper if desired. However, overspray
or driven rain may enter the vented space. Ventilator
with damper may function as a smoke exhaust vent by
including a fusible link in the chain operator.
Vents are furnished standard with white or galvalume
finish, but are available in special colors when specifically
ordered.
Construction
26 gauge inner and outer bands, rainshield, and base
assembly are assembled with four pre-formed baffles
into a simple yet sturdy ventilation unit. This design
achieves a free unobstructed flow of ventilation air.
Base Design
The base is specifically designed for the final installation,
with specified roof slope; either ridge or single slope, and
either flat or mounted into customer- furnished roof
panel. Base and ventilating unit are furnished pre-assembled ready for installation. Single slope bases are
mounted directly into roof panel and are placed in such a
way as to prevent damming.
Design
Round gravity roof ventilators are designed for economical, low volume air movement to ventilate warehouses,
light industrial buildings, attics, lofts and other buildings
requiring gravity or relief ventilation. They also are adaptable for use as discharge heads for mechanical or forced
air ventilation systems. The volume of gravity air movement can be controlled by the adjustable damper. The
damper is also effective in controlling water intrusion
from wind-driven rain and back draft conditions.
Installation is by use of standard formed closures, tape sealant, caulking and fasteners as indicated on standard assembly
drawings. When ordering, please specify roof slope and base type. A wooden crate is included in price.
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
RV-01 / Rev. 8/01
DIMENSIONS AND TECHNICAL DATA
W
RAIN
SHIELD
H
W
OUTER
BAND
OUTER
BAND
DAMPER
RAIN
SHIELD
SCREEN
H
DAMPER
CLOSURE
TH
DAMPER
SCREEN
DAMPER
CLOSURE
TH
SPRING (4)
INNER
BAND
RIDGE BASE
SPRING (4)
INNER
BAND
BAFFLE (4)
BAFFLE (4)
PULL CHAIN (5 FT.)
CHAIN CATCH
CHAIN CATCH
(OPTIONAL)
PULL CHAIN (5 FT.)
RIDGE BASE
THROAT OPENING
THROAT OPENING
12, 16, 24, 36 and 48" Throat Ventilators
20" Throat Ventilators
DIMENSIONS (In Inches)
SHIPPING WEIGHT
Throat*
W
H
TH
LBS.
12
20
24
18
30
36
71⁄2
10
12
141⁄2
171⁄2
231⁄2
38
65
73
Type 1
Type 2
Type 3
Type 4
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
Table of Capacities for Round Ventilators
TO ESTIMATE VENTILATOR CAPACITY:
Determine the height of vent above the air intakes and the “Temperature Difference” between inlet air temperature
and outlet air temperature with these two constants find the “Factor” from Table “A.” Multiply base rate C.F.M. from
“Table C” by the factor from “Table A.” The result is approximate vent capacity at “0” M.P.H. outside wind velocity.
Beside the factor in Table A is the letter A, B. C or D. This letter refers to a factor in Table “B.” Multiply vent capacity
for “0” M.P.H. wind by appropriate factor from Table “B” for vent capacity under the given wind condition.
EXAMPLE:
Use Ventilator Size 20"
Ventilator Height Above Intake 20'
Factor From Table “A” is .76A at 15 Temperature
Difference Multiply: .76 x 712 = 541 CFM at “0” M.P.H.
Using 3 M.P.H. Wind Vent Capacity is 541 x 1.14 = 617
C.F.M.
TABLE B
TABLE A
Wind Velocity Factors
Wind
Factors
M.P.H.
A
B
C
Height and Temperature Factors
Temperature Difference
HEIGHT
15
20
15
.64A
.76A
20
.78A
.86A
25
.84A
.93B
30
.90B
1.00B
35
.96B
1.07B
40
1.02B
1.13C
50
1.10C
1.22C
25
30
.84A
.91B
.95B
1.03B
1.02B
1.12C
1.10C
1.20C
1 18C
1.29C
1.25C
1.36C
1.34C
1.47D
35
40
.97B
1.02B
1.09B
1.15C
1.18C
1.25C
1.27C
1.34C
1.36C
1.43D
1.43D
1.52D
1.55D
1.64D
45
50
1.07B
1.11C
1.20C
1.26C
1.30C
1.36C
1.40C
1.46D
1.50D
1.56D
1.58D
1.65D
1.71D
1.78D
IN FEET
D
3
5
7
1.14
1.25
1.41
1.09
1.18
1.29
1.05
1.13
1.22
1.02
1.09
1.16
9
11
1.62
1.82
1.43
1.57
1.33
1.43
1.25
1.32
Size
Base Ratings Per Unit
12"
18"
20"
TABLE C
C.F.M.
256
577
712
24"
1026
RV-01.1 / Rev. 5/00
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: mpv@mpvent.com · www.mpvent.com
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
RV-01.2 / Rev. 2/01
PART:
INSTALLATION
DETAILS
ROUND GRAVITY
VENT
RV-5
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
APEX VENTILATOR
...is designed specifically for architectural standing-seam retrofit applications and new construction applications
where maximum ventilation is required in an attractive, compact-profile unit.
Standard Size
Construction
The Apex Ventilator comes standard in a 12-inch throat
size. Other sizes available upon request.
Screened outlet area prevents birds from entering ventilated area. All steel parts are 24 gauge steel. Screen is
expanded aluminum.
Design
The compact profile is an attractive design which allows for
self-acting ventilation of standing-seam roofs. There are no
moving parts to wear and no operating costs. No field
assembly means quick and easy installation.
Finish
Galvalume® finish is standard, and colors are available
including Kynar.® Please specify roof system, paint system
and color when ordering.
BUILDINGS MUST BREATHE!
One of the most overlooked components of design and
installation of architectural roofing systems, both in new construction and retrofit applications, is ventilation. A properly
engineered ventilation system using a continuous ridge vent in
conjunction with an under soffit intake will provide proper fresh
air movement through the roofing system removing hot, stale air.
Summer heat is released naturally, extending both the life and
performance of the roof. During winter proper ventilation can
assist in the control of condensation and other moisture problems
such as rust and insulation deterioration.
Ventilators manufactured by Metallic Products are in accordance with the highest design requirements and specifications.
25 years plus of experience in furnishing stationary, gravityflow, continuous ridge ventilators has proven their efficient
performance and lasting quality.
Apex Ventilators are a compact-profile, aesthetically pleasing and extremely efficient means of ventilating standing seam
roofs. The units are effective in the ventilation retrofit applications or in new construction.
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SV-03 / Rev. 2/01
DIMENSIONS AND TECHNICAL DATA
W
Cap
Rain Shield Angle
Upper Outer Band
Damper
H
Screen
Baffle
Eye Bolt
TH
Lower Outer Band
Spring
Inner Band
Guide Rod
Guide Rod Angle
Base
THROAT
DIMENSIONS (In Inches)
Throat*
W
H
TH
12
16
20
18
27
331⁄2
6
113⁄8
15
13
20
22
TABLE OF CAPACITIES FOR APEX VENTILATOR FOR WHOLE BUILDING VENTILATION
TO ESTIMATE VENTILATOR CAPACITY:
Determine the heights of vent above the air intakes and the “Temperature Difference” between inlet air temperature and outlet
air temperature. With these two constants, find the “Factor” from Table “A.” Multiply 256 (Base Rating for a 12" Apex Vent) by
the factor from “Table A.” The result is approximate vent capacity at “0” m.p.h. outside wind velocity. Beside the factor in “Table
A” is the letter A, B, C or D. This letter refers to a factor in Table “B.” Multiply vent capacity for “0” m.p.h. wind by appropriate
factor from Table “B” for vent capacity under the given wind condition.
EXAMPLE: Ventilator Height Above Intake = 20'
A measured 15° Temperature Difference yields .76A from “Table A”
Multiply .76 x 256 = 194.56 C.F.M. at “0” m.p.h.
At 3 m.p.h Wind Velocity, Vent Capacity is 194.56 x 1.14 = apprx. 221.8 C.F.M.
HEIGHT
IN FEET
15
20
25
30
35
40
45
50
TABLE A
Air Movement per Lineal Foot Factors
Temperature Difference
15°
.64A
.76A
.84A
.91B
.97B
1.02B
1.07B
1.11C
20°
.78A
.86A
.95B
1.03B
1.09B
1.15C
1.20C
1.26C
25°
.84A
.93B
1.02B
1.12C
1.18C
1.25C
1.30C
1.36C
30°
.90B
1.00B
1.10C
1.20C
1.27C
1.34C
1.40C
1.46D
35°
.96B
1.07B
1.18C
1.29C
1.36C
1.43D
1.50D
1.56D
40°
1.02B
1.13C
1.25C
1.36C
1.43D
1.52D
1.58D
1.65D
50°
1.10C
1.22C
1.34C
1.47D
1.55D
1.64D
1.71D
1.78D
TABLE B
Wind Velocity Factors
Factors
WIND
M.P.H.
3
5
7
9
11
A
1.14
1.25
1.41
1.62
1.82
B
1.09
1.18
1.29
1.43
1.57
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
C
1.05
1.13
1.22
1.33
1.43
D
1.02
1.09
1.16
1.25
1.32
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
TURBINE VENTILATORS
Turbine ventilators are available in 4" to 24" throat sizes.
They are constructed of 24 gauge galvanized steel with
bottom thrust-type oil impregnated ball bearings. Vents
are externally braced with aluminum painted steel bracing. Dampers are available upon request. Damper has
pull-chain operator.
Vents are mounted in standard metal building peak or
hillside base to pitch of building.
When ordering, specify throat size, slope, screen or
damper.
Turbines are shipped wood crated.
Type 1
Type 2
Type 3
Type 4
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SV-04 / Rev. 2/01
W
T
OILLESS BEARIMG
OUTSIDE BRACE
CROWN
BLADE
W
H
EXHAST
CAP
4MI WIND
CFM
APPROX.
SHIPPING
WEIGHT
10
19
17
425
17
12
20
19
531
21
14
20 1/2
22
700
28
16
23 1/4
25
950
35
18
24 1/4
27 1/2
1200
36
20
26
30
1700
47
24
31 1/4
35
2350
77
36
43
56
4600
225
NOTE: VENTS UP TO 16" HAVE THREE OUTSIDE BRACES.
VENTS 18" AND UP HAVE FOUR.
"T" DIM.
H
SEE ENLARGED DETAIL
OF SHAFT END
GREASE RESERVOIR
IN SHAFT HOUSING
T
CROWN
BLADE
THROAT
GALV.
GAUGE
GALV.
GAUGE
GALV.
GAUGE
10
22
28
26
12
22
28
26
14
22
26
24
16
20
26
24
18
20
26
24
20
20
26
24
24
20
26
24
36
20
24
20
SHAFT
DATE:
PRESS FIT STUD
DATE
INTO SHAFT
LOWER BEARING FOR
VENTILATORS 14"
AND UP
BALL BEARING
THRUS BEARING
FOR VENTS UP TO
& INCLUDING 12"
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
MAY 3, 1997
TITLE:
SPECIFICATIONS
PART:
TURBINE VENT
Commercial Fans
Domex
POWER VENTILATORS
Industrial Fans
HI-EX Fans
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
COMMERCIAL FANS
STANDARD FEATURES:
•
Wall-mount and roof-mount fans designed for
heavy-duty usage
•
Belt drive
•
Single-speed motors up to 5 hp (See options for
two speed motors)
•
Balanced steel blades
•
Vibration tested assembly
•
Self-lubricating ball bearings
•
•
OPTIONS:
•
Dual-speed switch
•
Timer (12 hour)
•
Combination dual-speed switch and timer
•
Interior fan guard
•
Exterior weather hood (helps prevent entrance of
moisture when fans are used for intake ventilation)
•
Large capacity motors (up to 5 hp, 230/460 volts,
with dual-speeds)
Standard motors are open drip-proof (ODP), 60Hz,
single phase, unless otherwise specified (See
options for additional motor types)
•
Two-speed motors, available on V series fans up
to 1/2 hp (CFM is reduced approximately 32% at
low speed)
Crated for shipment
•
Totally enclosed and explosion proof motors are
available for all VI series fans
NOTE: Fans are available with automatically-opening wall
shutters. Also available installed in roof curb with “Air Intake
and Exhaust-Hoods.”
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
PV-01 / Rev. 2/01
EASY SIX-STEP INSTALLATION:
1. Construct a frame of 8 inches or 10 inches “C” channels 1/4 inch
larger than the overall fan size.
2. After mounting “C” channel frame to the building structure, cut
opening in exterior metal siding for shutter frame.
3. Place the shutter in opening with flange under siding and attach
with self tapping or sheet metal screws. After shutter is installed, caulk all four exterior sides of shutter.
4. Install fan in position leaving a min. of 4 inches between front
of fan and shutter. Fan mounts to “C” channels with self tapping
screws or machine bolts with lock washers.
5. With fan and shutter installed, proceed with electrical wiring.
See the motor label for proper wiring procedures.
6. Install IG or VIG guard on fans mounted less than 7 ft. above
the floor.
SPECIFICATIONS
MODEL
HP
CFM
V 2412
V 3012
V 3613
V 4213
V 4813
V 4814
1/3
1/3
1/3
1/2
1/2
3/4
5,100
7,500
12,500
14,445
17,025
20,100
VI 3613
VI 3614
VI 3615
VI 4213
VI 4214
VI 4215
VI 4216
VI 4814
VI 4815
VI 4816
VI 4817
VI 4818
VI 5417
VI 5418
VI 5419
VI 6017
VI 6018
VI 6019
1/2
3/4
1
1/2
3/4
1
1 1 ⁄2
3/4
1
1 1 ⁄2
2
3
2
3
5
2
3
5
11,800
12,100
12,560
17,175
17,550
17,900
18,425
20,100
20,950
21,820
22,760
26,180
27,000
30,900
36,200
32,500
36,200
44,200
AMPS
BLADE
SIZE
VOLTS
V-SERIES COMMERCIAL
24"
115
30"
115
36"
115
42"
115
48"
115
48"
115/230
VI-SERIES INDUSTRIAL
7.8
36"
115
11.2/5.6
36"
115/230
11.0/5.5
36"
115/230 TE
7.8
42"
115
11.2/5.6
42"
115/230
11.0/5.5
42"
115/230 TE
4.6/2.3
42"
230/460/60/3
11.2/5.6
48"
115/230
11.0/5.5
48"
115/230 TE
4.6/2.3
48"
230/460/60/3
6.2/3.1
48"
230/460/60/3
8.8/4.4
48"
230/460/60/3
6.2/3.1
54"
230/460/60/3
8.8/4.4
54"
230/460/60/3
14.4/7.2
54"
230/460/60/3
6.2/3.1
60"
230/460/60/3
8.8/4.4
60"
230/460/60/3
14.4/7.2
60"
230/460/60/3
4.5
4.5
7.8
7.8
7.8
11.2/5.6
SHIPPING O/O SQ. FLANGE
DEPTH
WT. (LBS) SIZE
SIZE
44
52
66
72
81
89
30"
34"
40"
46"
52"
52"
11 ⁄ 2 "
11 ⁄ 2 "
2"
2"
2"
2"
131⁄2"
131⁄2"
131⁄2"
131⁄2"
131⁄2"
131⁄2"
150
153
158
158
168
173
175
182
184
190
197
210
338
343
343
410
418
422
40"
40"
40"
46"
46"
46"
46"
52"
52"
52"
52"
52"
62"
62"
62"
68"
68"
68"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
20"
20"
20"
20"
20"
20"
20"
20"
20"
20"
20"
20"
24"
24"
24"
24"
24"
24"
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
FAN SHUTTERS & ACCESSORIES
SHUTTERS
STANDARD FEATURES:
•
Shutter frames are heavy-gauge steel with rigidly
welded corners and finished with a tough, powder
coated finish
SPECIFICATIONS
MODEL
NUMBER
•
Aluminum shutter blades are attached with heavyduty nylon fasteners
IWS 24
•
Automatic open/close operation as fan is turned
on/off
IWS 30
•
Interlocking blades for maximum weather seal
IWS 36
•
Double-panel units constructed with rigid “T” section center member
IWS 42
•
Open depth of shutters is 4"
OPTIONS:
•
Manual pull chain and chain latch
•
Motor operator, 115/230 volts (relieves starting
load on fan motor)
•
IWS 48
*IWS 54
*IWS 60
DESCRIPTION
Shutter
33 3/8" x 33 3/8"
Shutter
36 3/8" x 36 3/8"
Shutter
42 3/8" x 42 3/8"
Shutter
48 3/8" x 48 3/8"
Shutter
54 3/8" x 54 3/8"
Shutter
64 3/8" x 64 3/8"
Shutter
70 3/8" x 70 3/8
FAN
SIZE
WALL
OPENING
SIZE
WT.
(LBS)
24"
31" x 31"
11
30"
34" x 34"
15
36"
40" x 40"
21
42"
46" x 46"
25
48"
52" x 52"
30
54"
61" X 61"
48
60"
67" X 67"
56
* INDICATES DOUBLE PANEL SHUTTER
Electrostatic powder coated finish, a standard
color
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
PV-02 / Rev. 3/01
FAN GUARDS
WEATHER
HOODS
The “IG” and “VIG” series Industrial Fan Guards should be
used on all fans mounted less than 7 ft. above the floor, to
meet OSHA requirements. The grill has black powder-coat
finish.
The “VIG” guard for “VI” series fans consists of the grill only
which attaches to the fan housing on the intake side.
The “IG” guard for “V” series fans is complete with 14 inch
deep galvanized housing and grill. It mounts on the intake
side of the fan and is shipped unassembled.
Fits
V Series Fans
MODEL
NUMBER
IG 3000
IG 3600
IG 4200
IG 4800
IG 5400
FAN
SIZE
24
30
36
42
48
SHIPPING
WT.
43
50
58
65
73
Fits
VI Series Fans
MODEL
NUMBER
VIG 36
VIG 42
VIG 48
VIG 54
VIG 60
FAN
SIZE
36
42
48
54
60
STANDARD FEATURES:
Offers protection from the elements when installed over
intake or exhaust fans, or over wall openings
•
Heavy-duty galvanized construction
•
Galvanized angle frames
•
Flange frame for securing to building structure
•
Standard sizes to accommodate 24", 30", 36", 42",
and 48" fans
•
1/2 inch mesh birdscreen at opening
•
Assembled and crated
OPTIONS:
•
Insect screen
•
Filter frames
•
Electrostatic powder-coated finish (2 mil)
•
Shipped “KD” (knocked-down) for field assembly
•
Also available in aluminum and Galvalume™ finishes
•
Custom sizes available
SHIPPING
WT.
27
31
34
38
45
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
BREEZEWAY WALL MOUNTED EXHAUST PROPELLER FANS
ACCESSORIES AVAILABLE:
• WALL SHUTTER (GRAVITY)
• WALL MOUNTING COLLAR (KNOCKED DOWN)
• FRONT AND BACK GUARD
DIRECT DRIVE (TYPE P)
Versatile fans from 10” to 24” utilizing multi-speed motors
in selected sizes, using fabricated props, with performances
up to 6500 cfm.
BELT DRIVE (TYPE BLL)
Penn Ventilation certifies that the Breezeway Models
are licensed to bear the AMCA Seal. The ratings
shown are based on tests and procedures performed in
accordance with the AMCA Publication 211 and
Publication 311 and comply with the requirements of
the AMCA Certified Ratings Program.
Breezeway fans carry the UL label, UL705, (ZACT),
File #E28413. Check Underwriters Laboratories ReExamination Service for specific units listed.
Low cost fans designed specifically for low pressure applications, utilizing steel props, available in the three most popular
sizes 24”, 30”, & 36”, with performances to 14,000 cfm.
BELT DRIVE (TYPE BFM)
Suitable in medium pressure applications beyond the BLL, utilizing steel props, available in all sizes from 24” to 48”, with
performances up to 32,400 cfm.
PDQ models are exhaust only. Fans for supply applications are
available through normal channels with standard lead times.
Penn Breezeway Fans are also certified by the
Canadian Standard Association (File #LR13309)
DIMENSIONAL DATA
TYPE P
MODEL
A
P10
15
P12
17
DIA.
MAX.
WALL APPROX
OPENING SHIP WT. PANEL
Wo
(LBS.)
GAUGE
15-3/4
12
18
C
MAX.
E
F
10-3/4
2-1/2
1
1-1/4
6-1/2
3/4
12-1/4
3-1/4
1
1
7-1/2
1-7/8
17-3/4
B
G
H
14
18
P16
22-3/4 16-3/4
3-3/4
1
2-1/4
11-1/4
2-7/8
23-1/2
30
18
P18
24-1/4 18-3/4
3-3/4
1
2
9-1/8
3-5/8
25
40
18
P20
26-3/4 20-7/8
3-3/4
1
1-3/4
12-1/2
3-1/4
27-1/2
50
18
P24
32-1/4
4-1/4
2
2-3/8
12-7/8
4- /16
11
33
76
18
25
All wire frames are 11 gauge.
MAX.
215.464.8900 • Penn Ventilation
E
F
A
MODEL BLL
B
A
DIA.
MODEL
BLL24
BLL30
BLL36
A
28
34
40
B
25
31
37
D
16
18
20
E
3
2-1/2
3
F
3
3
4-3/4
A
28
34
40
46
54
B
25
31
37
43
49
D
16
18
20
22
25
E
3
2-1/2
3
3-3/4
2-3/4
F
3
3
4-3/4
4-1/2
4-3/4
DMAX.
E
A
F
MODEL BFM
A
BDIA.
MODEL
BFM24
BFM30
BFM36
BFM42
BFM48
DMAX.
BREEZEWAY DIRECT DRIVE - P SERIES
MODEL
P10VA
P10RA
P12VA
P12RA
P16VA
P16SA
P16RA
P16Q1A
P18VA
P18RA
P20TA
P20SA
P24VA
MAX
HP WATTS
1/30
1/12
1/12
1/4
1/3
1/2
1/2
3/4
1/2
3/4
3/4
1
3/4
80
115
147
174
463
550
724
962
522
1265
815
1415
1117
RPM
1050
1550
1050
1550
1050
1300
1550
1650
1050
1550
1140
1300
1050
TIP
SPEED
(FPM)
2749
4058
3299
4869
4398
5445
6492
6911
4948
7304
5969
6807
6597
0.000" SP
CFM SONES
753
4.6
841
5.8
1343 10.7
1489 10.3
2546 9.1
3143 13.7
3555 14.0
3760 16.3
4210 15.2
5233 20
4852 16.2
6063 22
6562 14.6
24 MM
0.100" SP
CFM SONES
531
7.5
699
6.5
1177 9.5
1367 9.8
2088 8.8
2933 14.0
3301 14.1
3557 16.6
3845 15.1
4971 21
4449 16.4
5786 22
6210 14.6
UPS - P10VA thru P20SA
0.125" SP
CFM SONES
457
7.9
631
7.3
1123 9.9
1326 10.1
1859 8.7
2856 14.1
3256 14.1
3508 16.7
3768 15.1
4971 21
4318 16.5
5692 21
6136 14.7
Available for shipment from Junction City, KY, Reno, NV &
Farnham, Quebec, Canada.
FAN CAPACITY IN CUBIC FEET PER MINUTE (CFM)
0.150" SP
0.200" SP
0.250" SP
0.300" SP
CFM SONES CFM SONES CFM SONES CFM SONES
385
7.2
239
6.7
570
8.5
486 10.8 425 12.5 387 12.9
1057 10.5 874 11.1 689 10.1 433 10.0
1281 10.5 1160 11.7 1046 13.2 882 15.5
1699 8.6 1257 8.3
2758 14.3 2495 14.6 2244 15.0 1982 15.3
3211 14.2 3102 14.5 2955 15.3 2736 16.9
3459 16.7 3358 16.9 3256 17.1 3123 17.6
3661 15.1 3370 15.3 3030 15.1 2719 13.6
4919 21
4787 22
4633 23
4383 25
4185 16.7 3898 17.1 3570 17.7 3278 18.4
5597 21
5397 21
5149 21
4835 21
6063 14.7 5917 14.7 5758 14.9 5576 15.2
0.375" SP
0.500" SP
0.625" SP
CFM SONES CFM SONES CFM SONES
321
13.2
798
16.9
1671
2514
2864
2215
4029
2717
4466
5249
15.4
18.3
18.9
13.1
28
20
21
15.8
568
19.6
210
20
1979
2369
20
22
1772
2032
21
24
3547
1969
3909
4065
35
24
22
19.3
3083
1200
3121
3654
34
25
23
21
Performance shown is for installation Type A: Free Inlet, Free Outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are for loudness values in fan sones
at 5’0” (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for Installation Type A: free inlet fan sone levels. Performance ratings include the effect of backguard in the airstream. For
models shown on this page, the AMCA Certified Ratings Seal applies to air and sound. See page 33 for accessories. See page 34 for speed control availability.
BREEZEWAY V-BELT DRIVE - TYPE BLL
MODEL
BLL24
HP
RPM
1/4
737
TIP
SPEED
(FPM)
4631
1/3
792
4976
1/2
912
5730
3/4
BLL30
1048
6585
1
1124
7062
1/4
531
4170
1/3
572
4492
1/2
657
5160
3/4
1
756
810
5938
6362
0.000" SP
Sones
BHP
4771
15.5
0.28
5127
16.9
0.35
5904
22
0.53
6785
25
0.81
7277
31
1
6739
12.2
0.26
7260
13.8
0.33
8339
18.1
0.50
9595
21
0.76
10281
23
0.94
24 MM
0.100" SP
Sones
BHP
4209
14.4
0.30
4620
15.9
0.36
5465
21
0.55
6402
24
0.83
6920
29
1.02
5320
12.0
0.29
6007
13.7
0.36
7299
18.0
0.53
8671
21
0.80
9406
22
0.98
Available for shipment from Junction City, KY & Farnham, Quebec, Canada.
0.125" SP
Sones
BHP
4010
14.3
0.30
4456
15.7
0.37
5355
20
0.55
6306
24
0.83
6831
29
1.02
4767
12.2
0.29
5567
13.8
0.36
6988
18.0
0.54
8461
21
0.80
9210
23
0.98
FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)
0.150" SP
0.200" SP
0.250" SP
Sones
BHP
Sones
BHP
Sones
BHP
3798
3120
2353
14.2
0.30
14.2
0.30
14.7
0.30
4266
3753
3095
15.6
0.37
15.6
0.37
15.9
0.37
5226
4906
4484
20
0.56
19.4
0.57
19.1
0.57
6211
5996
5718
24
0.84
23
0.85
23
0.86
6742
6563
6333
29
1.03
28
1.04
27
1.05
4029
2138
12.4
0.27
13.7
0.28
5025
3123
1995
14.0
0.36
14.8
0.33
15.9
0.36
6632
5732
4020
18.0
0.54
18.5
0.54
19.5
0.51
8212
7612
6844
21
0.81
21
0.83
22
0.82
9015
8512
7891
23
0.99
23
1.01
23
1.02
0.300" SP
Sones
BHP
0.375" SP
Sones
BHP
3934
19.1
3010
0.57
19.6
5432
23
24
6066
1.06
27
0.53
22
0.87
4426
1.07
27
1.07
0.57
3619
0.79
24
7129
23
24
1675
5908
22
3405
0.87
5567
2762
21
0.57
4735
0.86
27
0.500" SP
Sones
BHP
1887
0.79
26
5107
1.01
24
0.87
2842
0.95
27
1.01
Performance shown is for installation Type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. The sound ratings shown are for loudness values in fan sones at 5’0” (1.5m) in a hemispherical free field per AMCA standard 301. Values shown are for installation Type A: Free inlet fan sone levels. Performance ratings do not include the effects of appurtenances in the airstream. See page 33 for
accessories.
Penn Ventilation • 215.464.8900
24 MM
Motors Mounted, complete ready to ship within 24 hours
BREEZEWAY V-BELT DRIVE - TYPE BLL
MODEL
BLL36
HP
RPM
1/4
381
TIP
SPEED
(FPM)
3561
1/3
410
3832
1/2
472
4411
3/4
543
5075
1
582
5440
0.000" SP
Sones
BHP
9017
9.9
0.25
9703
11.4
0.31
11170
15.3
0.48
12851
18.9
0.73
13774
19.8
0.90
24 MM
0.100" SP
Sones
BHP
5770
9.6
0.26
7170
10.6
0.33
9272
14.2
0.50
11260
18.4
0.76
12296
20
0.93
FAN
0.125" SP
Sones
BHP
3780
10.3
0.27
5052
11.3
0.31
8626
13.8
0.51
10819
18.2
0.76
11913
20
0.94
CAPACITY - CUBIC FEET PER MINUTE (CFM)
0.150" SP
0.200" SP
0.250" SP
Sones
BHP
Sones
BHP
Sones
BHP
2949
10.6
0.29
3829
11.8
0.34
7417
4361
14.3
0.50
15.6
0.52
10302
8471
5522
18.0
0.77
18.3
0.76
19.3
0.77
11473
10238
7234
20
0.94
19.9
0.95
20
0.90
0.300" SP
Sones
BHP
0.350" SP
Sones
BHP
4295
19.8
0.85
5508
21
4505
0.98
21
1.05
Performance shown is for installation Type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. The sound ratings shown are for loudness values in fan sones at 5’0” (1.5m) in a hemispherical free field per AMCA standard 301. Values shown are for installation Type A: Free inlet fan sone levels. Performance ratings do not include the effects of appurtenances in the airstream. See page 33 for
accessories.
BREEZEWAY V-BELT DRIVE - TYPE BFM
24 MM
TIP
SPEED
0.000" SP
(FPM) Sones BHP
4342
5290
14.7
0.29
4669
5688
16.0
0.36
5375
6548
19.7
0.55
6177
7525
24
0.84
6619
8064
26
1.03
7607
9267
31
1.56
3529
6875
15.1
0.29
3801
7404
15.0
0.36
4368
8508
16.8
0.55
5022
9784
20
0.83
5390
10499
23
1.03
6188
12055
28
1.56
6827
13299
33
2.09
3431
8137
8.5
0.26
3695
8763
9.7
0.32
4251
10082
12.0
0.49
4882
11579
16.2
0.75
5240
12429
18.0
0.92
6022
14284
27
1.40
6635
15738
27
1.87
7615
18062
39
2.83
4431
15483
18.1
1.03
5091
17788
22
1.56
5619
19632
27
2.10
6443
22514
32
3.17
7653
26740
40
5.30
3958
17478
13.5
0.75
4247
18754
15.4
0.93
4888
21584
18.8
1.42
5391
23803
22
1.90
6183
27299
31
2.87
7339
32404
44
4.80
0.100" SP
Sones BHP
4524
13.9
0.30
5007
15.4
0.37
5992
19.2
0.56
7061
23
0.84
7643
25
1.03
8903
30
1.57
5618
14.8
0.30
6297
14.7
0.37
7589
16.7
0.57
9013
19.8
0.86
9794
22
1.06
11451
27
1.59
12760
31
2.13
5969
9.1
0.30
7051
10.2
0.37
8838
12.2
0.55
10601
16.0
0.81
11542
17.6
1.00
13541
26
1.49
15076
26
1.97
17494
38
2.94
13597
17.1
1.06
16241
21
1.60
18267
26
2.15
21367
31
3.22
25775
40
5.37
14975
12.9
0.84
16504
14.7
1.03
19726
17.8
1.54
22159
21
2.04
25906
30
3.03
31260
43
5.00
MODEL
HP
RPM
1/4
677
1/3
728
1/2
838
3/4
963
BFM24
BFM30
1
1032
1-1/2
1186
1/4
442
1/3
476
1/2
547
3/4
629
1
675
1-1/2
775
2
855
1/4
364
1/3
392
1/2
451
3/4
518
1
556
1-1/2
639
BFM36
2
3
BFM42
704
808
1
403
1-1/2
463
2
511
3
5
586
696
3/4
315
1
338
1-1/2
389
2
429
BFM48
3
5
492
584
0.125" SP
Sones BHP
4250
13.7
0.30
4771
15.0
0.37
5822
18.9
0.56
6925
23
0.84
7515
25
1.04
8812
30
1.57
5065
14.7
0.30
5906
14.7
0.37
7314
16.6
0.57
8793
19.7
0.86
9592
22
1.06
11289
26
1.60
12614
31
2.14
5109
9.4
0.30
6106
10.5
0.37
8301
12.4
0.56
10266
16.0
0.83
11269
17.6
1.01
13327
25
1.51
14892
26
1.99
17347
38
2.96
12906
16.7
1.07
15785
21
1.61
17875
25
2.15
21038
31
3.23
25533
40
5.39
14138
12.9
0.85
15767
14.6
1.04
19169
17.7
1.56
21690
21
2.07
25516
30
3.07
30951
43
5.05
FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)
0.150" SP
0.200" SP
0.250" SP
0.375" SP
Sones BHP
Sones BHP
Sones BHP
Sones BHP
3936
3192
1898
13.6
0.30
13.4
0.30
13.4
0.30
4508
3902
2934
14.6
0.37
14.5
0.37
14.5
0.37
5625
5176
4657
2489
18.6
0.56
18.0
0.57
17.8
0.56
17.7
0.56
6788
6451
6068
4919
23
0.85
22
0.86
22
0.86
21
0.86
7388
7104
6773
5771
24
1.04
24
1.05
24
1.06
23
1.05
8704
8482
8243
7500
30
1.57
29
1.58
29
1.59
28
1.61
3891
14.4
0.28
5311
3514
14.5
0.37
14.0
0.36
6996
6056
4248
16.5
0.57
16.1
0.57
15.4
0.54
8557
8025
7275
4306
19.5
0.86
19.4
0.86
19.2
0.87
18.2
0.86
9385
8940
8393
5342
22
1.07
22
1.07
22
1.06
20
1.01
11118
10758
10370
9040
26
1.61
25
1.61
25
1.61
26
1.62
12467
12153
11822
10861
30
2.15
30
2.16
29
2.17
29
2.16
5365
10.8
0.37
7517
12.8
0.57
9852
15.9
0.85
10927
17.6
1.03
13098
25
1.53
14696
26
2.01
17186
38
2.99
12076
16.3
1.05
15201
21
1.62
17469
25
2.16
20695
31
3.24
25290
40
5.40
13265
13.0
0.86
14979
14.6
1.05
18556
17.5
1.58
21184
20
2.09
25115
29
3.10
30631
42
5.09
6138
13.5
0.57
8563
16.4
0.86
10026
17.5
1.06
12533
24
1.57
14273
26
2.06
16850
37
3.04
10151
15.9
1.01
13802
20
1.59
16389
24
2.17
19983
30
3.26
24714
39
5.43
9778
13.4
0.85
12841
14.9
1.06
17203
17.4
1.61
20046
20
2.13
24244
29
3.16
29970
42
5.18
7335
17.1
0.85
8698
18.4
1.06
11778
24
1.61
13719
25
2.10
16487
37
3.09
7012
16.4
1.02
12064
19.7
1.53
15026
24
2.13
19059
30
3.28
24137
39
5.45
9510
15.4
1.06
15621
17.5
1.62
18806
20
2.16
23269
29
3.20
29270
42
5.25
9144
1.61
11526
26
2.16
15245
35
3.22
0.500" SP
Sones BHP
0.625" SP
Sones BHP
2788
0.86
4201
23
1.06
6597
28
1.59
28
5390
1.61
6038
1.53
9276
30
2.16
28
6505
2.08
9390
2.17
13124
35
3.26
35
11221
3.26
11359
3.08
19604
37
5.3
37
16948
5.19
14860
3.25
24926
41
5.46
41
20362
5.41
21
25
24
10227
2.04
15925
28
3.13
22251
38
5.49
27
23
13159
2.15
20490
28
3.27
27209
41
5.38
28
21
30
Performance shown is for installation Type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. The sound ratings shown are for loudness values in fan sones at 5’0” (1.5m) in a hemispherical free field per AMCA standard 301. Values shown are for installation Type A: Free inlet fan sone levels. Performance ratings do not include the effects of appurtenances in the airstream. See
page 33 for accessories. See page 34 for speed control availability.
Available for shipment from Junction City, KY & Farnham, Quebec, Canada.
215.464.8900 • Penn Ventilation
HI-EX VERTICAL DISCHARGE AIR EXHAUSTERS
AVAILABLE WITH:
• MOTOR (SEE PAGE 34)
• DISCONNECT SWITCH
• INLET GUARD
• MAGNETIC LATCHES
• REMOTE DRIVE (HC AND HF ONLY)
A continuing demand exists in commercial and industrial buildings for high
velocity roof ventilators which exhaust foul air and disperse it high above the
roof. The HI-EX is ideal for the “spot” ventilation of specific problem areas
where rapid air removal is necessary or for general plant ventilation. This
“plug-in” or package ventilation is easily installed out of the way, up on the
roof. It is accessible and yet does not use valuable interior areas nor does it
require costly duct systems.
Dampers open automatically when the fan is started. The airstream holds the
dampers open and excludes weather until the power is shut off. Then, the
dampers automatically close tight as the air blast diminishes.
All units are galvanized construction.
DIMENSIONAL DATA HI-EX MODELS HC, HF
L
V - BELT DRIVE MODELS HC, HF
FAN
DIAM. A
H
L
Ro
T
E
26
32
38
44
50
40
44
48
51
60
33
39
45
51
57
26
32
38
44
51
331/2
391/2
451/2
511/2
581/2
35
41
47
53
60
24
30
36
42
48
FABRICATED
UNIBEAM
CURB
O2
301/2
361/2
421/2
481/2
551/2
T2
331/2
391/2
451/2
511/2
581/2
GAUGE
A
STEEL
16-20
16-20
16-20
14-18
14-18
H
E SQ. INSIDE BASE
T2
O2
R0
HI-EX MODEL HC (CAST ALUMINUM PROP)
TIP
RPM
SPEED
MODEL
F.P.M.
1105 6943
1265 7948
HC24
1450 9111
1595 10022
890 6690
1020 8011
HC30 1125 8836
1285 10092
0”S.P.
CFM BHP
4895 0.29
5600 0.43
6420 0.65
7065 0.87
8485 0.42
9725 0.63
10725 0.84
12250 1.26
10 QB
FAN CAPACITY C.F.M.
.125”S.P.
.250”S.P.
.375”S.P.
.500”S.P.
CFM BHP CFM BHP CFM BHP CFM BHP
4350 0.32 3610 0.33 2730 0.33 2015 0.35
5150 0.46 4505 0.49 3850 0.49 3080 0.49
6030 0.68 5555 0.72 4935 0.74 4370 0.74
6715 0.90 6315 0.95 5800 0.97 5240 0.99
7525 0.46 6415 0.49 4545 0.48 2120 0.45
8920 0.69 8025 0.72 6785 0.74 5075 0.72
10010 0.92 9180 0.95 8310 0.99 6980 1.00
11640 1.35 10925 1.40 10200 1.44 9430 1.48
.750”S.P.
CFM BHP
1.000”S.P.
CFM BHP
1895
3030
4080
0.55
0.77
0.98
2115
3045
0.83
1.05
3300
6985
0.92
1.46
3525
1.37
Power rating (BHP) does not include drive losses. Performance shown is for installation Type A: Free inlet, Free outlet. Performance ratings include the effects of the dampers. See page 31 for
roof curb availability.
10 QB
Quick Build, 10 day custom build program. Available for shipment from Junction City, KY & Farnham, Quebec, Canada.
215.464.8900 • Penn Ventilation
HI-EX MODEL HC (CAST ALUMINUM PROP)
MODEL
HC36
HC42
HC48
TIP
RPM SPEED
F.P.M.
635 5985
700 6597
800 7540
880 8294
1010 95196
550 048
630 6927
695 7642
795 8742
945 10391
540 6787
600 7540
685 8608
810 10179
0”S.P.
CFM BHP
11585 0.69
12770 0.92
14595 1.37
16055 1.83
18425 2.76
14775 0.94
16925 1.41
18670 1.89
21360 2.84
25390 4.76
20740 1.40
23045 1.92
26310 2.86
31110 4.72
10 QB
.125”S.P.
CFM BHP
10150 0.73
11500 0.97
13515 1.44
15085 1.90
17595 2.85
12845 0.98
15300 1.47
17225 1.97
20120 2.92
24365 4.88
18060 1.45
20660 1.98
24245 2.93
29385 4.81
FAN CAPACITY C.F.M.
.250”S.P.
.375”S.P.
.500”S.P.
.750”S.P.
1.000”S.P.
CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP
8080 0.74 4455 0.67
9780 1.00 7590 0.97 3955 0.88
12225 1.48 10490 1.48 8455 1.44
13970 1.86 12550 1.98 10995 1.96 5575 1.75
16675 2.92 15660 2.98 14340 2.99 11415 2.92 6280 2.64
9775 0.98 5870 0.94
13025 1.48 9945 1.47 6495 1.40
15450 1.98 12895 1.99 9895 1.97
18705 2.96 16840 2.98 14570 2.97 9240 2.85
23250 4.95 22055 4.97 20445 5.00 1660 4.98 12085 4.85
14775 1.44 9805 1.35
17935 2.00 14605 1.94 8295 1.82
21995 2.98 19410 2.96 16410 2.88
27565 4.89 25595 4.93 23415 4.91 18515 4.72
Power rating (BHP) does not include drive losses. Performance shown is for installation Type A: Free inlet, Free outlet. Performance ratings include the effects of the dampers. See page 31 for
roof curb availability.
HI-EX MODEL HF (STEEL PROP)
10 QB
TIP
MODEL RPM SPEED
HF24
HF30
HF36
HF42
HF48
611
672
750
857
943
440
484
538
615
678
775
370
412
470
520
594
654
750
391
430
492
542
620
735
323
355
407
448
513
608
F.P.M.
3839
4222
4712
5385
5925
3465
3801
4225
4830
5325
6087
3487
3883
4430
4901
5598
6164
7069
4299
4728
5410
5960
6817
80824
059
4461
5115
5630
6447
7640
0”S.P.
CFM BHP
4890 0.30
5375 0.39
6000 0.55
6855 0.82
7545 1.09
6640 0.29
7305 0.39
8120 0.54
9280 0.80
10230 1.08
11695 1.61
9445 0.40
10515 0.55
11995 0.82
13270 1.11
15160 1.65
16690 2.20
19140 3.32
14530 0.81
15980 1.08
18285 1.62
20145 2.17
230 3.25
27315 5.41
18195 0.81
20000 1.08
22930 1.62
25235 2.16
28900 3.25
34250 5.41
FAN CAPACITY C.F.M.
.125”S.P.
.250”S.P.
.375”S.P.
CFM BHP CFM BHP CFM BHP
4075 0.30 2565 0.29 1735 0.33
4685 0.40 3190 0.38 2325 0.41
5410 0.55 4190 0.52 3155 0.54
6320 0.81 5680 0.81 4320 0.78
7065 1.08 6555 1.10 5470 1.04
4525 0.28 2280 0.31
5655 0.38 2450 0.40
6775 0.54 3815 0.52 2775 0.57
8225 0.82 6190 0.76 3530 0.80
9335 1.10 7845 1.05 5205 1.02
10970 1.64 9860 1.62 8200 1.54
6950 0.37
8265 0.52 3875 0.51
10120 0.78 7570 0.75 3135 0.78
11640 1.07 9705 1.02 5585 1.02
13815 1.60 12060 1.56 10115 1.51
15500 2.15 13980 2.10 12530 2.05
18135 3.26 16895 3.20 15505 3.15
12940 0.81 7480 0.80
14735 1.09 10485 1.05 5830 1.13
17370 1.64 15090 1.57 10210 1.59
19355 2.19 17765 2.15 14030 2.09
22410 3.28 21370 3.28 19555 3.17
26830 5.45 26115 5.47 25090 5.45
13475 0.82
16030 1.09 9080 1.13
19810 1.65 14585 1.65
22595 2.20 18310 2.20 12585 2.24
26810 3.30 23500 3.30 19230 3.30
32680 5.49 30245 5.49 27235 5.49
.500”S.P.
CFM BHP
2495
3550
4425
0.58
0.80
1.04
3085
3325
5785
0.86
1.10
1.53
6090 1.52
10190 2.02
14275 3.08
9765 2.14
15760 3.13
23665 5.30
14060 3.37
23625 5.50
Power rating (BHP) does not include drive losses. Performance shown is for installation Type A: Free inlet, Free outlet. Performance ratings include
the effects of the dampers. See page 31 for roof curb availability.
10 QB
Penn Ventilation • 215.464.8900
Quick Build, 10 day custom build program. Available for shipment from Junction City, KY & Farnham, Quebec, Canada.
HITESAVER MODEL HS V-BELT DRIVE
RECOMMENDED FOR COMMERCIAL USE
For applications where height is a consideration, Penn introduces the HiteSaver, Model HS.
The HiteSaver features an extra-low profile. The propeller, motor and drive are recessed into
the roof opening and extend below the roof line. This design provides for convenient access
from the building interior when structural members provide clearance.
The windband is constructed of galvanized steel and contains two reinforcing ribs. This
assembly is supported by the curb base and steel brackets. The curb base is all-welded heavy
gauge galvanized steel with a deep spun venturi to smooth airflow. External bracing provides extra rigidity. Integral lifting lugs are included.
Penn Ventilation certifies that the Model HS Roof Exhausters
shown are licensed to bear the AMCA Seal. The ratings shown are
based on tests and procedures performed in accordance with
AMCA Publication 211 and Publication 311 and comply with the
requirements of the AMCA Certified Ratings Program.
PERFORMANCE DATA
MODEL
HS30
HS36
HS42
HS48
RPM
743
797
915
1008
514
551
633
697
465
513
588
698
799
391
431
495
587
673
10 QB
TIP
SPEED
F.P.M.
5836
6260
7186
7917
4844
5193
5966
6569
5113
5641
6465
7675
8785
4913
5416
6220
7376
8457
0" S.P.
CFM
BHP
9174
0.78
9841
0.96
11298
1.45
12446
1.94
12345
0.78
13234
0.96
15203
1.45
16740
1.94
17921
1.50
19770
2.01
22661
3.03
26900
5.07
30793
7.60
21647
1.45
23862
1.94
27406
2.94
32499
4.91
37261
7.39
.125"
CFM
8309
9039
10611
11831
10563
11578
13775
15447
15971
18029
21162
25638
29690
18724
21390
25370
30793
35772
FAN CAPACITY – C.F.M.
S.P.
.250" S.P.
.375"
BHP
CFM
BHP
CFM
0.83
7258
0.87
1.02
8105
1.06
1.52
9838
1.58
8968
2.02
11156
2.09
10410
0.84
1.03
9831
1.08
1.53
12265
1.60
2.03
14108
2.11
12731
1.57
13683
1.63
2.09
15986
2.15
3.12
19467
3.19
17654
5.17
24325
5.27
22827
7.72
28586
7.84
27386
1.54
14310
1.54
6884
2.05
17699
2.09
12463
3.07
22454
3.15
19095
5.05
28783
5.19
26130
7.56
34212
7.73
32142
S.P.
BHP
.500" S.P.
CFM
BHP
1.62
2.14
9586
2.17
21297
26037
5.44
8.03
14094
23272
29828
3.13
5.29
7.96
2.17
3.27
5.35
7.95
1.62
2.06
3.17
5.28
7.86
SONES
@
0.125"
15.4
17.9
23
27
15.8
17.0
19.6
22
16.7
20
26
35
44
17.0
20
25
32
39
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. The sound ratings shown are for loudness values in fan sones
at 5'0" (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation type A: free inlet fan sone levels. Performance ratings include the effect of
backdraft damper in the airstream.
DIMENSIONAL DATA
FAN DIAM.
30
36
42
48
H
24
26
30
32
L
36
42
48
54
Ro
34
40
46
52
E
38-1/2
44-1/2
50-1/2
56-1/2
F
15
15
18
18
ALL DIMENSIONS IN INCHES.
This model also available UL Listed for Heat & Smoke Control
through normal channels with standard lead time.
10 QB
Quick Build, 10 day custom build program. Available for shipment from Junction City, KY & Farnham, Quebec, Canada.
215.464.8900 • Penn Ventilation
DOMEX CENTRIFUGAL ROOF EXHAUSTERS
Domex spun aluminum centrifugal roof fans are ideal for high volume, lower pressure air exhaust.
These durable products are found on roofs throughout the world in a wide range of commercial,
industrial and institutional buildings. Domex units include deep spun venturis, all aluminum nonoverloading wheels and can include optional Lektrol speed controller (Direct Drive only) and curb.
These models carry the AMCA Certified Ratings seal, UL and CSA labels.
DIRECT DRIVE
V-BELT DRIVE
ALL UNITS STOCKED WITH:
• 115/1/60 OPEN DRIP PROOF MOTOR
• POLARIZED DISCONNECT PLUG
• INTERNAL WIRING
• ALUMINUM BIRD SCREEN
• BACKDRAFT DAMPER
ALL UNITS STOCKED WITH:
• MOTOR (SEE PAGE 34)
• POWER DISCONNECT SWITCH
• INTERNAL WIRING
• ALUMINUM BIRD SCREEN
• BACKDRAFT DAMPER
DOMEX
HIGH CAPACITY V-BELT DRIVE
Penn Ventilation certifies that the Domex Direct and
Belt Drive Models shown are licensed to bear the
AMCA Seal. The ratings shown are based on tests
and procedures performed in accordance with
AMCA Publication 211 and Publication 311 and
comply with the requirements of the AMCA Certified
Ratings Program.
Penn Ventilation certifies that the Domex High
Capacity Belt Drive Models shown are licensed to
bear the AMCA Seal. The ratings shown are based on
tests and procedures performed in accordance with
AMCA Publication 211 and Publication 311 and
comply with the requirements of the AMCA Certified
Ratings Program.
DIMENSIONAL DATA - DIRECT & V-BELT DRIVE
MODELS DX08, DX10, & DX11
MODEL DX13
MODELS DX12B, DX14B, DX16B,
DX18B, DX24B, DX30B, & DX36B*
MODELS DX06B, DX08B, & DX11B
L (Dia.)
L (Dia.)
L (Dia.)
L (Dia.)
H
E (Sq., inside base)
H
E (Sq., inside base)
E (Sq., inside base)
MODEL DX16
E (Sq., inside base)
L (Dia.)
L (Dia.)
High Capacity Models KB420 & JB48
H
Belt Drive Models DX06B DX30B available:
24 MM
Models DX36B - JB48 available from Tabor City, NC only:
10 QB
E (Sq., inside base)
E (Sq., inside base)
Direct Drive Models available:
24 MM
Motors Mounted, complete ready to ship within 24 hours
MODEL
DIA.
L
20-7/8
H
E*
Roof Opening
DX08S/R
13-3/8
18-1/2 X 18-1/2
9X9
DX10S/R
20-7/8
13-3/8
18-1/2 X 18-1/2 11-1/2 X 11-1/2
DX11V/S/R & Q
20-7/8
13-3/8
18-1/2 X 18-1/2 11-1/2 X 11-1/2
DX13V/S/R & Q
21- /16
28-1/2
7
14-3/4
18-1/2 X 18-1/2 11-1/2 X 11-1/2
22-1/2
20-1/2 X 20-1/2
DX16V/S/R, Q1 & Q2
16 X 16
MODEL
DX06B
DX08B
DX11B
DX12B
DX14B
DX16B
DX18B
DX24B
DX30B
DX36B
KB420
JB48
DIA.
L
21-11/16
21-11/16
28-1/2
33-1/2
33-1/2
39
39
46
53-1/2
66
63
73
H
18-13/16
18-13/16
25-7/16
29
29
31
31
33-1/2
35-1/2
41
38
45-1/2
18-1/2
18-1/2
20-1/2
24-3/4
24-3/4
28-1/2
28-1/2
33-1/2
36-1/2
44-1/2
52-1/2
59
E*
Roof Opening
X 18-1/2 11-1/2 X 11-1/2
X 18-1/2 11-1/2 X 11-1/2
X 20-1/2
16 X 16
X 24-3/4
16 X 16
X 24-3/4
16 X 16
X 28-1/2
20 X 20
X 28-1/2
20 X 20
X 33-1/2
25 X 25
X 36-1/2
28 X 28
X 44-1/2
36 X 36
X 52-1/2
44 X 44
X 59
50 X 50
215.464.8900 • Penn Ventilation
DOMEX DIRECT DRIVE
24 MM
UPS - DX08S THRU DX13Q
FAN CAPACITY – CUBIC FEET PER MINUTE (CFM)
Fan
Model
0.000" SP
0.125" SP
0.250" SP
0.375" SP
0.500" SP
0.625" SP
0.750" SP
0.875" SP
1.000" SP
1.250" SP
HP
Max Watts
Nominal
RPM
Tip Speed
FPM
CFM
SONES
CFM
SONES
CFM
SONES
CFM
SONES
CFM
SONES
CFM
SONES
CFM
SONES
CFM
SONES
CFM
SONES
CFM
SONES
DX08S
1/50
44
1300
3361
237
1.5
161
2.2
114
3
69
3.8
DX08R
1/30
55
1550
4007
290
2.4
223
2.8
171
3.5
129
4.1
84
4.9
DX10S
1/25
82
1300
3361
385
3.9
316
3.5
257
4.8
207
5.1
168
5.2
129
5.6
82
6.1
DX10R
1/12
121
1550
4007
559
6.1
501
5.9
446
6.1
394
6.5
338
6.8
267
7
187
7.2
100
7.4
DX11V
1/25
111
1050
3058
388
1.8
223
2.2
148
3.1
112
3.7
80
4.5
49
5.3
DX11S
1/11
142
1300
3786
503
3.4
397
3.6
320
4.3
262
5
201
5.5
149
6
104
6.5
DX11R
1/7
201
1550
4514
736
6.7
659
6.4
577
6.6
502
6.9
432
7.6
356
7.9
274
7.9
188
7.9
100
7.9
DX11Q
1/5
268
1725
5024
997
10.2
921
9.7
850
9.5
768
9.5
685
9.4
598
9.2
511
9
409
8.7
294
8.6
DX13V
1/20
92
1050
3221
661
4.4
479
3.1
341
2.8
262
3.6
207
4.3
161
5.1
115
5.9
79
6.6
44
7.4
DX13S
1/12
120
1300
3988
869
8
749
6.4
632
5.3
510
5.4
418
6
349
6.4
290
6.7
226
7
158
7.4
DX13R
1/6
201
1550
4755
1054
10.5
988
9.9
917
9.2
839
8.9
736
8.5
651
8.2
579
7.9
510
7.9
428
8
191
8.5
DX13Q
1/4
314
1725
5292
1280
16
1226
15.3
1170
14.6
1112
14
1053
13.4
995
13
936
12.5
868
12
796
11.5
630
11
DX16V
1/6
453
1050
3788
1738
9.9
1489
8
1256
6.6
1032
6.1
884
6.6
772
7.1
682
7.9
598
9.9
529
10.1
392
10.2
DX16S
1/3
510
1300
4690
2021
12
1822
10.6
1637
9.5
1428
8.7
1256
8.4
1094
8.5
943
9.3
850
10.2
775
11
606
12.3
DX16R
1/2
574
1550
5592
2346
13.8
2176
12.8
2014
12
1853
11.3
1685
10.7
1532
10.4
1384
10.1
1247
10
1115
10.4
881
12.4
DX16Q1
1/2
688
1650
5953
2701
16.9
2576
16.4
2465
15.9
2352
15.5
2228
15
2096
14.4
1966
14
1839
13.6
1700
13.5
1401
13.5
DX16Q2
3/4
866
1725
6223
3016
17.7
2921
17.1
2829
16.7
2747
16.3
2665
15.9
2575
15.5
2484
15
2371
14.6
2256
14.2
2005
13.3
Performance shown is for installation Type A: Free Inlet, Free Outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are for loudness values in fan sones at
5'0" (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for Installation Type A: free inlet fan sone levels. See page 34 for speed control availability. Performance ratings do not include
the effects of appurtenances in the airstream. See page 31 for roof curb availability.
DOMEX V-BELT DRIVE
MODEL
HP
RPM
24 MM
TIP
SPEED
0.000" SP
0.125" SP
FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)
0.250" SP
0.375" SP
0.500" SP
0.625" SP
0.750" SP
(FPM)
Sones
Sones
Sones
Sones
Sones
873
8.2 0.17
1011
10.1 0.26
956
10.4 0.16
1108
12.5 0.25
1/6
1240
3612
1/4
1437
4185
DX06B
1/6
1240
3804
1/4
1437
4185
DX08B
MODEL
HP
RPM
BHP
BHP
783
7.6 0.17
933
9.5 0.26
885
9.4 0.16
1049
11.8 0.25
BHP
Sones
675
6.9 0.16
845
9.1 0.25
803
8.6 0.17
979
11.1 0.26
BHP
Sones
547
6.4 0.15
750
8.5 0.25
719
8.1 0.17
909
10.5 0.26
BHP
389
5.8 0.14
638
8.0 0.24
626
7.7 0.17
836
9.9 0.26
0.000" SP
(FPM)
Sones
1884
10.2 0.23
2053
11.5 0.29
2360
14.0 0.44
2716
17.4 0.67
1768
9.6 0.24
1948
11.0 0.30
2271
13.6 0.46
2638
17.2 0.69
1639
9.1 0.24
1834
10.5 0.31
2172
13.2 0.47
2555
16.9 0.71
1496
8.3 0.25
1708
9.8
0.32
2069
12.8 0.48
2468
16.6 0.72
0.125" SP
0.250" SP
FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)
0.375" SP 0.500" SP 0.625" SP 0.875" SP 1.000" SP
BHP Sones
1/4
1093
3943
1/3
1191
4297
1/2
1369
4939
3/4
1575
5682
HP
RPM
TIP
SPEED
0.000" SP
(FPM)
Sones
2027
13.7 0.21
2208
15.0 0.27
2540
18.1 0.40
2921
22.0 0.61
1/4
1039
4318
1/3
1132
4705
1/2
1302
5411
3/4
1497
6222
DX12B
0.125" SP
BHP Sones
0.250" SP
BHP Sones
BHP Sones
1894
13.2 0.22
2091
14.4 0.28
2439
17.6 0.42
2833
21.0 0.63
FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)
0.375" SP 0.500" SP 0.625" SP 0.750" SP 0.875" SP
BHP Sones
BHP Sones
1737
12.6 0.24
1946
13.9 0.30
2319
17.1 0.44
2737
21.0 0.65
BHP Sones
1329
7.9 0.26
1568
9.0 0.34
1959
12.1 0.48
2377
16.3 0.73
BHP Sones
1597
12.2 0.25
1813
13.4 0.31
2195
16.6 0.46
2627
20.0 0.68
BHP Sones
1111
7.7 0.26
1406
8.8 0.34
1838
11.4 0.51
2282
15.6 0.74
BHP Sones
1422
11.7 0.26
1673
13.0 0.33
2082
16.0 0.48
2520
19.7 0.71
BHP Sones
BHP
158
5.3 0.11
509
7.9 0.22
509
7.4 0.16
756
9.8 0.26
TIP
SPEED
DX11B
MODEL
UPS - DX06 & DX08B
BHP Sones
347
0.20
279
6.8 0.14
669
9.8 0.26
7.9
1.000" SP
BHP Sones
BHP
1.125" SP
BHP Sones
BHP
758
7.7 0.23
1193
883
8.6 0.34 8.6 0.31
1703
1556
1352
1095
11.0 0.52 10.8 0.52 10.9 0.51 10.9 0.48
2180
2073
1952
1825
15.0 0.76 14.4 0.78 14.3 0.79 14.3 0.79
BHP Sones
BHP Sones
1.125" SP
BHP Sones
1.250" SP
BHP Sones
BHP
1219
11.6 0.26
1503
1058
12.7 0.34 12.5 0.33
1963
1668
1503
1280
869
15.4 0.49 14.7
0.52 14.9 0.52 15.2 0.51 14.5 0.45
2421
2212
2091
1953
1811
19.2 0.72 18.1 0.75 17.5 0.77 17.2 0.78 17.3 0.79
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. FanSizer software automatically calculates drive losses when selecting equipment. The sound
ratings shown are for loudness values in fan sones at 5'0' (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet fan sone levels. Performance ratings do
not include the effects of appurtenances in the airstream. See page 31 for roof curb availability.
24 MM
Motors Mounted, complete ready to ship within 24 hours. Available for shipment from Tabor City, NC, Reno, NV & Farnham, Quebec, Canada.
Penn Ventilation • 215.464.8900
DOMEX V-BELT DRIVE
MODEL
DX14B
HP
RPM
1/4
958
1/3
1044
1/2
1200
3/4
1380
1
1498
1/4
694
1/3
755
1/2
868
3/4
997
1
1081
1 1/2
1241
1/4
635
1/3
691
1/2
794
3/4
912
1
989
1 1/2
1136
2
1252
1/4
448
1/3
488
1/2
561
3/4
645
1
700
1 1/2
805
2
887
1/3
372
1/2
428
3/4
492
1
534
1 1/2
614
2
677
3
777
5
923
DX16B
DX18B
DX24B
DX30B
24 MM
TIP
SPEED 0.000" SP
(FPM) Sones BHP
3982
2606
11.8 0.23
4339
2840
13.1 0.29
4987
3264
17.3 0.45
5735
3754
19.5 0.68
6226
4075
22.0 0.87
3395
2889
10.4 0.23
3694
3142
11.9 0.30
4247
3613
14.3 0.45
4878
4150
17.4 0.68
5289
4500
18.9 0.87
6072
5166
23.0 1.31
3366
3345
10.1 0.22
3663
3640
10.9 0.28
4209
4182
14.2 0.43
4835
4804
17.1 0.65
5243
5209
19.9 0.82
6022
5984
23.0 1.25
6637
6595
26.0 1.67
2906
4306
8.6 0.22
3166
4690
9.7 0.28
3640
5392
11.6 0.43
4185
6200
14.5 0.65
4541
6728
15.5 0.83
5223
7738
19.1 1.27
5755
8526
21.0 1.69
2983
5753
8.7 0.27
3432
6619
10.4 0.41
3945
7609
13.1 0.62
4281
8259
14.7 0.79
4923
9496
17.4 1.20
5428
10471
19.5 1.61
6230
12018
23.0 2.44
7400
14276
29.0 4.09
0.125" SP
Sones
0.250" SP
BHP Sones
2415
11.2 0.24
2662
12.6 0.31
3109
16.8 0.46
3619
19.1 0.70
3951
22.0 0.89
2677
10.0 0.24
2950
11.6 0.31
3447
13.9 0.47
4005
17.1 0.70
4366
18.6 0.89
5050
23.0 1.34
3037
9.7 0.24
3360
10.5 0.31
3943
13.7 0.46
4595
16.8 0.68
5017
19.6 0.87
5816
23.0 1.30
6443
26.0 1.73
3873
7.9 0.25
4303
9.1 0.32
5075
11.0 0.47
5926
14.0 0.71
6477
15.0 0.89
7519
18.6 1.33
8327
21.0 1.77
5164
8.0 0.30
6120
9.7 0.45
7183
12.1 0.67
7871
13.9 0.85
9162
16.9 1.27
10168
19.0 1.69
11754
22.0 2.53
14054
29.0 4.19
FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)
0.375" SP 0.500" SP 0.625" SP 0.750" SP 1.000" SP
BHP Sones
2226
10.6 0.26
2499
12.1 0.33
2965
16.3 0.48
3488
18.6 0.72
3826
21.0 0.91
2450
9.7 0.26
2744
11.1 0.33
3271
13.5 0.49
3856
16.7 0.72
4231
18.3 0.92
4933
22.0 1.37
2711
9.1 0.26
3062
10.1 0.33
3685
13.2 0.48
4376
16.3 0.71
4819
19.2 0.90
5649
22.0 1.34
6291
26.0 1.78
3251
7.3 0.26
3766
8.4 0.34
4650
10.4 0.49
5601
13.4 0.73
6191
14.5 0.93
7298
18.1 1.40
8129
20.0 1.84
4386
7.4 0.33
5514
9.0 0.49
6695
11.0 0.71
7443
13.2 0.89
8801
16.2 1.32
9848
18.6 1.75
11488
22.0 2.61
13831
29.0 4.30
BHP Sones
1977
10.0 0.26
2292
11.4 0.34
2812
15.8 0.50
3367
18.2 0.74
3714
21.0 0.93
2212
9.3 0.27
2528
10.7 0.34
3088
13.2 0.50
3701
16.4 0.74
4088
17.9 0.94
4812
22.0 1.39
2291
8.3 0.26
2751
9.3 0.34
3424
12.5 0.50
4151
15.8 0.74
4612
18.7 0.92
5470
22.0 1.34
6134
26.0 1.82
2278
4.7 0.24
3087
6.9 0.33
4142
9.6 0.51
5196
12.6 0.76
5847
13.9 0.96
7022
17.6 1.42
7898
19.7 1.89
3184
6.6 0.32
4747
8.3 0.51
6136
10.3 0.76
6939
12.4 0.94
8405
15.6 1.37
9513
18.2 1.80
11196
22.0 2.67
13603
28.0 4.39
BHP Sones
BHP Sones
BHP Sones
1.250" SP
BHP Sones
1.500" SP
BHP Sones
BHP
1699
8.8 0.26
2044
10.7 0.34
2627
15.1 0.52
3229
17.8 0.76
3602
20.0 0.96
1707
8.8 0.25
2266
10.3 0.34
2900
12.8 0.51
3540
16.0 0.76
3943
17.6 0.96
4688
22.0 1.42
1355
7.6 0.25
1788
9.4 0.34
2412
14.4 0.52
3071
17.2 0.78
3465
19.8 0.98
1445
8.4 0.32
2191
1629
12.9 0.52 10.6 0.49
2891
2507
2080
699
16.6 0.79 14.9 0.79 13.1 0.76 12.9 0.45
3317
2974
2618
2200
19.3 1.00 18.1 1.01 16.3 1.00 14.6 0.97
1620
9.7 0.31
2690
12.3 0.52
3377
15.7 0.78
3794
17.2 0.97
4563
21.0 1.44
2314
11.6 0.51
3212
2608
15.2 0.79 13.9 0.77
3643
3299
2484
16.8 0.99 15.9 1.01 14.7 0.93
4432
4170
3884
3398
21.0 1.46 20.0 1.50 19.1 1.53 17.8 1.51
2162
8.5 0.34
3150
11.6 0.52
3923
15.1 0.76
4403
18.2 0.95
5289
22.0 1.37
5970
25.0 1.85
2684
10.6 0.51
3684
14.3 0.78
4190
17.5 0.98
5108
21.0 1.44
5806
25.0 1.88
1604
10.3 0.41
3376
13.4 0.78
3969
16.7 1.00
4925
21.0 1.47
5641
24.0 1.92
3517
8.2 0.50
4747
11.9 0.78
5450
13.3 0.99
6713
17.0 1.45
7648
19.2 1.91
4226
10.8 0.76
5031
12.6 1.00
6374
16.5 1.50
7352
18.6 1.95
3466
8.8 0.73
4531
11.5 0.97
6009
5182
3788
15.9 1.51 14.1 1.48 12.0 1.35
7046
6384
5561
4317
18.1 2.00 17.0 2.04 15.3 1.97 13.9 1.83
3627
7.4 0.49
5430
9.4 0.78
6375
11.6 0.98
7964
14.9 1.43
9129
17.7 1.86
10905
21.0 2.73
13357
28.0 4.46
4490
8.7 0.76
5691
10.6 1.00
7493
14.2 1.49
8724
16.9 1.92
10569
21.0 2.79
13112
28.0 4.53
4760
9.5 0.97
6917
13.2 1.50
8302
16.1 1.99
10224
20.0 2.86
12859
28.0 4.60
1675
12.3 0.59
3213
14.9 0.99
4543
3945
2625
19.2 1.52 17.7 1.49 16.8 1.29
5307
4958
4399
23.0 1.99 22.0 2.05 21.0 2.00
5412
10.9 1.47
7235
5744
14.2 2.03 12.5 1.96
9485
8564
7426
18.7 3.01 17.1 3.06 15.5 3.01
12284
11680
11001
27.0 4.75 25.0 4.95 23.0 5.07
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. FanSizer software automatically calculates drive losses when selecting equipment. The sound
ratings shown are for loudness values in fan sones at 5'0' (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet fan sone levels. Performance ratings do
not include the effects of appurtenances in the airstream. See page 31 for roof curb availability.
24 MM
Motors Mounted, complete ready to ship within 24 hours. Available for shipment from Tabor City, NC, Reno, NV & Farnham, Quebec, Canada.
215.464.8900 • Penn Ventilation
DOMEX V-BELT DRIVE
MODEL
DX36B
10 QB
1/2
307
TIP
SPEED
(FPM)
2989
3/4
352
3427
1
382
3719
1 1/2
439
4274
2
484
4712
3
555
5403
5
659
6416
HP
RPM
0.000" SP
Sones
0.125" SP
BHP Sones
9057
8.0 0.39
10385
10.6 0.58
11270
12.4 0.75
12951
16.1 1.13
14279
18.8 1.52
16374
23.0 2.29
19442
29.0 3.83
0.250" SP
BHP Sones
8105
7.7 0.46
9613
10.2 0.65
10589
12.1 0.82
12397
16.1 1.23
13798
18.8 1.63
15969
23.0 2.43
19101
29.0 4.00
FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)
0.375" SP 0.500" SP 0.625" SP 0.750" SP 1.000" SP
BHP Sones
6994
7.6 0.51
8675
9.5 0.74
9705
11.3 0.92
11627
15.4 1.33
13139
18.6 1.71
15452
23.0 2.50
18722
29.0 4.13
BHP Sones
7497
9.1 0.79
8809
10.6 0.99
10904
14.7 1.43
12432
18.0 1.85
14826
22.0 2.65
18255
29.0 4.22
BHP Sones
7438
9.9 1.00
10089
14.0 1.50
11778
17.2 1.95
14223
22.0 2.80
17730
28.0 4.38
BHP Sones
BHP Sones
1.250" SP
BHP Sones
1.500" SP
BHP Sones
BHP
8939
13.1 1.53
10998
9945
16.5 2.02 15.8 2.06
13662
13039
11292
21.0 2.91 20.0 3.00 18.9 3.09
17205
16722
15732
14438
12737
28.0 4.57 27.0 4.74 26.0 4.97 24.0 5.17 23.0 5.10
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. FanSizer software automatically calculates drive losses when selecting equipment. The sound
ratings shown are for loudness values in fan sones at 5'0' (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet fan sone levels. Performance ratings do
not include the effects of appurtenances in the airstream. See page 31 for roof curb availability.
DOMEX HIGH CAPACITY MODELS
MODEL
HP
RPM
3/4
283
1
308
1 1/2
354
2
390
3
447
5
532
7 1/2
599
3/4
205
1
225
1 1/2
255
2
280
3
320
5
380
7 1/2
430
10
480
KB420
JB48
10 QB
TIP
SPEED 0.000" SP
(FPM) Sones BHP
3223
9967
7.6 0.77
3508
10847
8.4 0.99
4031
12467
9.8 1.49
4441
13735
11.2 1.98
5091
15743
13.2 2.97
6059
18737
15.9 4.97
6822
21096
18.5 7.08
2683
14390
6.8 0.77
2945
15794
7.6 1.02
338
17900
8.9 1.49
3665
19655
9.9 1.97
4189
22463
12.0 2.94
4974
26675
15.1 4.92
5629
30185
17.6 7.12
6283
33695
20.0 9.91
0.125" SP
Sones
0.250" SP
BHP Sones
8479
7.4 0.78
9497
8.1 1.01
11307
9.4 1.51
12682
10.7 2.01
14824
12.7 2.99
17964
15.3 5.01
20410
17.9 7.12
11552
6.4 0.78
13298
7.3 1.03
15809
8.5 1.51
17829
9.5 2.00
20890
11.6 2.98
25387
14.6 4.97
29048
16.9 7.19
32676
19.8 9.98
FAN CAPACITY - CUBIC FEET PER MINUTE (CFM)
0.375" SP 0.500" SP 0.625" SP 0.750" SP 1.000" SP
BHP Sones
6607
7.1 0.77
7905
7.8 1.00
10017
9.0 1.51
11565
10.3 2.01
13889
12.2 3.01
17192
14.8 5.04
19724
17.3 7.16
7750
6.2 0.71
10237
7.0 0.99
13195
8.1 1.48
15448
9.1 1.97
18960
11.1 2.97
23940
13.9 4.99
27829
16.2 7.23
31616
19.7 10.03
BHP Sones
BHP Sones
BHP Sones
BHP Sones
1.250" SP
BHP Sones
1.500" SP
BHP Sones
BHP
5889
7.5 0.95
8492
6700
8.6 1.49 8.4 1.42
10299
8785
7013
10.0 2.00 9.6 1.96 9.5 1.86
12852
11732
10422
9019
11.8 3.01 11.6 3.00 11.4 2.95 11.3 2.87
16390
15523
14603
13621
11334
14.2 5.05 13.8 5.04 13.8 5.03 13.7 5.02 13.6 4.87
19038
18306
17535
16725
14978
12909
16.7 7.19 16.1 7.19 15.7 7.18 15.7 7.17 15.7 7.13 15.7 6.95
10060
7.6 1.39
13008
8.6 1.92
16853
10.5 2.93
22198
13.2 4.97
26419
15.5 7.23
30496
19.7 10.07
9318
8.1 1.72
14669
10.1 2.86
20396
12.5 4.92
24867
14.7 7.19
29131
19.7 10.04
11625
9.7 2.66
18673
16640
12.1 4.86 11.9 4.73
23270
21783
18188
11780
14.0 7.13 13.5 7.08 13.4 6.79 13.4 5.65
27737
26307
23555
20246
15161
19.7 10.00 19.7 9.93 19.7 9.79 19.7 9.43 19.7 8.45
Performance shown is for installation type A: Free Inlet, Free Outlet. Power rating (BHP) does not include drive losses. FanSizer software automatically calculates drive losses when selecting equipment. The sound
ratings shown are for loudness values in fan sones at 5'0' (1.5m) in a hemispherical free field per AMCA Standard 301. Values shown are for installation Type A: free inlet fan sone levels. Performance ratings do
not include the effects of appurtenances in the airstream. See page 31 for roof curb availability.
At Penn Ventilation’s option, large frame motors may be removed after testing and shipped separately.
10 QB
Quick Build, 10 day custom build program. Available for shipment from Tabor City, NC & Farnham, Quebec, Canada.
Penn Ventilation • 215.464.8900
Gable Louvers
Dormer Louvers
LOUVERS
Round Louvers
Fixed and Adjustable Louvers
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
WALL LOUVERS
Frame: 18 gauge galvanized steel.
Blades: 20 gauge roll-formed galvanized steel.
Features: Louvers are self mulling. Louvers are selfflashing and self-framing. No other trim required.
Before painting, louvers are steam-cleaned and treated.
Louvers can be painted to match pre-selected colors by
manufacturer. Standard paint is an electrostatically applied
polyester paint, 2 mil thick oven baked finish.
For adjustable louvers: After the paint process is
completed, an extruded weather stripping is applied to the
Wall Louvers as manufactured by Metallic Products are
specifically designed for pre-engineered metal building wall panels. Both fixed and operable models are available. Louvers are selfflashing requiring no additional flashing to complete installation in
standard “R” and “A” type wall panels. Additionally, the frame
design allows the louvers to be installed individually, one above
the other or side by side, without the need for additional mullions
or frames.
Modular Louvers are constructed of 18GA. frames and 20GA.
blades, G90 galvanized steel. Frame construction enables easy
installation of single or multiple units interconnected. The selfflashing frame is designed specifically for either “A” type or “R”
type flanges. Please specify panel type when ordering. The frame
has a recessed head to accept the wall panel and side flanges fit
specified panel profile on 1' modules. The sill is tapered to provide
drainage and exclude moisture. Flat flange louvers are also available for installation into framed openings. (Note: Self-flashing
louvers can be made to fit framed openings if specified when
ordering.) All welds are water tight and made from noncorroding
siliconized bronze wire and finished after fabrication.
edge of each blade to ensure virtual air tightness in the
closed position.
Insect screen: 18/16 aluminum mesh installed in an
extruded removable, re-wireable aluminum frame.
Blade Operators: Twin link brackets plated steel
assembled with double brass pivot and set screw.
Connecting Rod: 1/4 " zinc plated steel.
Operator: Standard operator is by a reinforced cast
aluminum hand crank. OPTIONAL: Chain operator of #35
sash chain, with plastic-coated chain pull handle.
Fixed louvers feature 45° roll-formed blades, with 4" depth,
and riveted to louver frame for security. Fixed louvers have 55%
free area, beginning of water penetration 600 FPM.
Adjustable louvers feature roll-formed blades with plated
twin link pivot brackets riveted to blade and connected with 1/4"
zinc plated rod and assembled with brass pivot and set screw for
smooth, noncorrosive, long-lasting operation. Standard operator is
by reinforced cast aluminum hand crank. Louver can be factory or
field modified for chain operation when louver is installed where
hand crank is not accessible. Motorized operators are also available. Blade edge seals are installed for maximum air sealing.
Adjustable louvers have 77% free area, beginning of water
penetration 500 FPM.
Louvers are available with galvanized finish or can be factory
painted utilizing an eletrostatic polyester powder paint and oven
baked for long lasting and durable finish. Additional materials
available are stainless steel, aluminum and aluminized zinc. All
louvers are shipped with an 18/16 aluminum insect screen mounted
in a removable, rewireable frame. Hardware cloth is also available.
louvers are shipped individually in heavy duty cardboard cartons.
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SL-01 / Rev. 2/01
13⁄ 4"
41⁄ 8"
COVER
VERTICAL SECTION
WITH R PANEL JAMB
WITH A PANEL JAMB
NOMINAL
SCREEN
VERTICAL SECTION - FIXED BLADES
11⁄ 2"
11⁄ 2"
ELEVATION
13⁄ 4"
OPERATOR
45⁄ 8"
HORIZONTAL SECTION
SCREEN
SEE JAMB TYPES BELOW
SCREEN
11⁄ 4"
11⁄ 2"
11⁄ 2"
13⁄ 8"
3⁄ 4" 7
⁄ 8"
NOMINAL
A PANEL
⁄ 8"
7
1⁄ 4"
NOMINAL
NOMINAL
R PANEL
JAMB TYPES
FLAT FLANGE
NOTE: Any combination
of head and sill types
can be ordered.
NOMINAL
NOMINAL
1⁄ 4"
NOMINAL
NOMINAL
SELF-FLASHING
FLAT FLANGE
HEADER TYPES
1⁄ 4"
SELF-FLASHING
FLAT FLANGE
SILL TYPES
MULTI-UNIT INSTALLATION
(SELF MULLING)
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
SL-02/1 / Rev. 3/94
SL-02/2 / Rev. 06/00
POWDER PRODUCTS INC.
SL-03/1 / Rev. 2/01
POWDER PRODUCTS INC.
SL-03/2 / Rev. 2/01
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
SL-01.1 / Rev. 2/01
PART:
SECTION
DRAWINGS
LOUVER
FREE-FLOW
GALVANIZED STEEL STATIONARY LOUVER
Features
Standard Construction Frame
* Architecturally styled
* All galvanized steel construction
4" deep 18 gauge galvanized steel
Blade
Options
20 gauge galvanized steel, 45° angle, spaced 39⁄16"
center to center
Changes to the basic design of this louver are
available at additional cost. They include:
1. Extended sill
2. A variety of bird or insect screen
3. Selection of finishes: Baked enamel, polyurethane
4. Mullions if needed
(Not for A Panel or R Panel Type)
Screen
Expanded 18-16 aluminum insect screen in
removable frame.
Finish
Mill
HEADER TYPES
1/4"
NOMINAL
NOMINAL
SILL TYPES
NOMINAL
NOMINAL
1/4"
SELF FLASHING
FLAT FLANGE
A DIM
JAMB TYPES
R PANEL
FLAT FLANGE
B DIM
A PANEL
1 1/4" NOMINAL
1 1/2" NOMINAL
1/4" NOMINAL
ORDERING INFORMATION
Circle Panel Type Above
QTY.
A DIM
B DIM
SIDE
PROFILE
OPTIONS
NOTE:
MINIMUM SIZE IS 12" X 12"
DATE:
TITLE:
7777 Hollister
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-04
/ Rev.
00/00
SL-01.3
/ Rev.
06/00
PART:
4/22/97
6/27/00
FLAT SKIRT
GALVANIZED
APPLICATION
STEEL
STATIONARY
RIDGE VENT
LOUVER
GALVANIZED STEEL FIXED LOUVER
WITH STORM-PROOF BLADES
Features
Standard Construction Frame
Blade
* Architecturally styled
* All galvanized steel construction
• Blade and Jamb Seals
20 gauge galvanized steel
Options
Screen
Changes to the basic design of this louver are
available at additional cost. They include:
1. Extended sill
2. A variety of bird or insect screen
3. Selection of finishes: Baked enamel or epoxy color
)
match.(
4" deep 18 gauge galvanized steel
18-16 aluminum insect screen in removable frame.
Finish
Mill
HEADER TYPES
1/4"
NOMINAL
NOMINAL
SILL TYPES
NOMINAL
NOMINAL
1/4"
SELF FLASHING
FLAT FLANGE
A DIM
JAMB TYPES
R PANEL
FLAT FLANGE
B DIM
A PANEL
1 1/4" NOMINAL
1 1/2" NOMINAL
1/4" NOMINAL
BLADE
PROFILE
ORDERING INFORMATION
Circle Panel Type Above
Indicate FINISH in Options Above
QTY.
A DIM
B DIM
SIDE
PROFILE
OPTIONS
NOTE:
MINIMUM SIZE IS 12" X 12"
DATE:
6/27/004/22/97
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-04
/ Rev.
00/00
SL-01.4
/ Rev.
06/00
PART:
FLAT SKIRT
STEEL
APPLICATION
LOUVER
STORM-PROOF
RIDGE VENT
BLADES
GALVANIZED STEEL FIXED GABLE LOUVER
Features
Standard Construction Frame
* Architecturally styled
4" deep formed 18 gauge galvanized steel
Options
Blade
9
20 gauge galvanized steel, 45° angle, spaced 3 ⁄16"
between blades
Flange Type
Flat flange
Screen
Changes to the basic design of this louver are
available at additional cost. They include:
1. A variety of bird or insect screen
2. Selection of finishes: Baked enamel, polyurethane
)
(
3. Sheeted above and below
4. Sheeted below only
Expanded aluminum birdscreen
Finish
Mill
3"
1 1/2"
BACK VIEW
ACCORDING TO PITCH
BASE DIMENSION
FRONT VIEW
ORDERING INFORMATION
Indicate FINISH in Options Above
QTY.
BASE
PITCH
BLADE PROFILE
SIDE PROFILES
OPTIONS
DATE:
TITLE:
7777 Hollister
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-04
00/00
AL-02 / Rev. 06/00
PART:
4/22/97
6/27/00
FLAT SKIRT
GALVANIZED
APPLICATION
STEEL
FIXED
RIDGE VENT
GABLE LOUVER
ALUMINUM STATIONARY STORMPROOF BLADE LOUVER
Features
Standard Construction Frame
* Architecturally styled
* All aluminum construction for low maintenance and
high resistance to corrosion
4" deep formed .080 aluminum
Blade
Extruded aluminum.080 J type blade, 45° angle,
spaced 4" center to center
Options
Changes to the basic design of this louver are
available at additional cost. They include:
1. Extended sill
2. A variety of bird or insect screen
3. Selection of finishes: Baked enamel, polyurethane
or anodized.(
)
4. Mullions if needed
(Not for A panel or R panel type)
Screen
Expanded 18-16 aluminum insect screen in removable frame
Finish
Mill
HEADER TYPES
1/4"
NOMINAL
NOMINAL
SILL TYPES
NOMINAL
A PANEL
NOMINAL
1/4"
JAMB TYPES
SELF FLASHING
R PANEL FLAT FLANGE
FLAT FLANGE
1 1/4" NOMINAL
1 1/2" NOMINAL
1/4" NOMINAL
ORDERING INFORMATION
B DIM
A DIM
BLADE
PROFILE
Circle Panel Type Above
Indicate FINISH in Options Above
QTY.
A DIM
B DIM
SIDE
PROFILE
OPTIONS
NOTE:
MINIMUM SIZE IS 12" X 12"
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-04 / Rev. 00/00
SL-01.5 / Rev. 06/00
PART:
4/22/97
6/27/00
FLAT SKIRT
ALUMINUM
APPLICATION
STATIONARY
STORMPROOF
RIDGE VENT
BLADES
ALUMINUM STATIONARY LOUVER
WITH DRAINABLE BLADES
Features
Standard Construction Frame
* Architecturally styled
* All aluminum construction for low maintenance and
high resistance to corrosion
4" deep formed .080 aluminum
Blade
Drainable extruded aluminum .080 J type blade, 45°
angle, spaced 4" center to center
Options
Changes to the basic design of this louver are
available at additional cost. They include:
1. Extended sill
2. A variety of bird or insect screen
3. Selection of finishes: Baked enamel, polyurethane
)
or anodized.(
4. Mullions needed for continuous run
Screen
Expanded 18-16 aluminum insect screen in
removable frame.
Finish
Mill
HEADER
1/4"
NOMINAL
SILL
NOMINAL
1/4"
FLAT FLANGE
JAMB
BLADE
PROFILE
B DIM
A DIM
ORDERING INFORMATION
Indicate FINISH in Options Above
QTY.
A DIM
B DIM
SIDE
PROFILE
OPTIONS
NOTE:
MINIMUM SIZE IS 12" X 12"
DATE:
6/27/004/22/97
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-04
/ Rev.
00/00
SL-01.6
/ Rev.
06/00
FLAT SKIRT
ALUMINUM
APPLICATION
STATIONARY
DRAINABLE
RIDGE VENT
BLADE
PART:
ALUMINUM FIXED GABLE LOUVER
Features
Standard Construction Frame
* Architecturally styled
* All aluminum construction for low maintenance and
high resistance to corrosion
3" deep formed .080 aluminum
Blade
Extruded aluminum .080 J type blade, 45° angle,
spaced 33⁄4" between blades
Flange Type
Flat flange
Screen
Expanded aluminum birdscreen
Finish
Options
Changes to the basic design of this louver are
available at additional cost. They include:
1. A variety of bird or insect screen
2. Selection of finishes: Baked enamel, polyurethane
or anodized (
)
3. Sheeted above and below
4. Sheeted below only
Mill
3"
1 1/2"
BACK VIEW
ACCORDING TO PITCH
BASE DIMENSION
FRONT VIEW
ORDERING INFORMATION
Indicate FINISH in Options Above
QTY.
BASE
PITCH
BLADE PROFILE
SIDE PROFILES
OPTIONS
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77018
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-04
00/00
AL-03 / Rev. 06/00
PART:
4/22/97
6/27/00
FLAT SKIRT
ALUMINUM
APPLICATION
FIXED
RIDGE VENT
GABLE LOUVER
ALUMINUM ROUND LOUVER
WITH STORM-PROOF BLADES
Features
Standard Construction Frame
* Architecturally styled
* All aluminum construction for low maintenance and
high resistance to corrosion
3" deep formed .080 aluminum
Blade
Extruded aluminum .080 J type blade, 45° angle,
spaced 4" center to center
Screen
Expanded aluminum birdscreen
Finish
Mill
Options
Changes to the basic design of this louver are
available at additional cost. They include:
1. A variety of bird or insect screen
2. Selection of finishes: Baked enamel, polyurethane
or anodized (
)
3. Mullions if needed
WEATHER BAND
LOUVER
BLADE PROFILE
SIDE PROFILE
ORDERING INFORMATION
Indicate PANEL TYPE for weather band
QTY. DIAMETER PANEL TYPE
OPTIONS
NOTE:
MINIMUM SIZE IS 24" DIAMETER
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-04
00/00
AL-01 / Rev. 6/00
PART:
4/22/97
6/27/00
FLAT SKIRT
ALUMINUM
APPLICATION
ROUND
LOUVER
STORM-PROOF
RIDGE VENT
BLADES
INSTALLATION INSTRUCTIONS FOR
ALUMINUM ROUND LOUVER
LOUVER
WEATHER BAND
SHEETS
HOLE
1. CUT HOLE IN SHEET
2. PUT WEATHER BAND IN OPENING
3. SCREW WEATHER BAND TO SHEETS AND CAULK
4. PUT LOUVER INSIDE WEATHER BAND
5. SCREW LOUVER TO WEATHER BAND
DATE:
6/27/004/22/97
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-04
/ Rev.
00/00
AL-01.1
/ Rev.
06/00
FLAT SKIRT
ALUMINUM
APPLICATION
ROUND
LOUVER
INSTALLATION
RIDGE VENT
INSTRUCTIONS
PART:
DATE:
TITLE:
7777 Hollister Raod
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
SL-01.2 / Rev. 2/01
PART:
CHAIN PULL
INSTA LLATION
LOUVER
VARI-FLOW
ADJUSTABLE GALVANIZED STEEL BACK PIVOT LOUVER
Finish
Standard Construction Frame
4" deep 18 gauge galvanized steel channel type
Mill
Blade
Features
20 gauge galvanized steel, 85° and spaced 3 ⁄16"
center to center
* Architecturally styled
* All galvanized steel construction
* Blade and jamb seals
Operator Type
Options
Hand Crank
Changes to the basic design of this louver are
available at additional cost. They include:
1. Extended sill
2. A variety of bird or insect screen
3. Selection of finishes: Baked enamel, polyurethane
color match.(
)
4. Pull Chain Operators available
5. Motor available
6. Mullions if needed
(Not for A panel or R panel type)
9
Screen
18-16 aluminum insect screen in removable frame.
HEADER TYPES
1/4"
NOMINAL
NOMINAL
SILL TYPES
NOMINAL
NOMINAL
1/4"
SELF FLASHING
FLAT FLANGE
A DIM
JAMB TYPES
R PANEL FLAT FLANGE
B DIM
A PANEL
1 1/4" NOMINAL
1 1/2" NOMINAL
1/4" NOMINAL
ORDERING INFORMATION
Circle Panel Type Above
Indicate FINISH in Options Above
QTY.
A DIM
B DIM
SIDE
PROFILE
OPTIONS
NOTE:
MINIMUM SIZE IS 12" X 12"
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-04
/ Rev.
00/00
SL-01.7
/ Rev.
06/00
PART:
4/22/97
6/27/00
FLAT SKIRT
GALVANIZED
APPLICATION
STEEL
BACK
PIVOT
RIDGE
VENT
LOUVER
ADJUSTABLE GALVANIZED STEEL CENTER PIVOT LOUVER
Finish
Standard Construction Frame
4" deep 18 gauge galvanized steel channel type
Mill
Blade
Features
20 gauge galvanized steel, 45° and spaced 3 ⁄16"
center to center
* Architecturally styled
* All galvanized steel construction
* Blade and jamb seals
Operator Type
Options
Hand Crank
Changes to the basic design of this louver are
available at additional cost. They include:
1. Extended sill
2. A variety of bird or insect screen
3. Selection of finishes: Baked enamel, polyurethane
color match.(
)
4. Pull Chain Operators available
5. Motor available
6. Mullions if needed
(Not for A panel or R panel type)
9
Screen
18-16 aluminum insect screen in removable frame.
HEADER TYPES
1/4"
NOMINAL
NOMINAL
SILL TYPES
NOMINAL
NOMINAL
1/4"
SELF FLASHING
FLAT FLANGE
A DIM
JAMB TYPES
R PANEL
FLAT FLANGE
3 9/16"
B DIM
A PANEL
1 1/4" NOMINAL
1 1/2" NOMINAL
1/4" NOMINAL
ORDERING INFORMATION
Circle Panel Type Above
Indicate FINISH in Options Above
QTY.
A DIM
B DIM
4"
SIDE
PROFILE
OPTIONS
NOTE:
MINIMUM SIZE IS 12" X 12"
DATE:
6/27/004/22/97
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-04
/ Rev.
00/00
SL-01.8
/ Rev.
06/00
PART:
FLAT SKIRT
GALVANIZED
APPLICATION
STEEL
CENTER
RIDGEPIVOT
VENT
LOUVER
ADJUSTABLE GALVANIZED STEEL CENTER PIVOT
CHANNEL TYPE LOUVER
Finish
Standard Construction Frame
4" deep 18 gauge galvanized steel channel type
Mill
Blade
Features
20 gauge galvanized steel, 45° and spaced 3 ⁄16"
center to center
* Architecturally styled
* All galvanized steel construction
* Blade and jamb seals
Operator Type
Options
Hand Crank
Changes to the basic design of this louver are
available at additional cost. They include:
1. Extended sill
2. A variety of bird or insect screen
3. Selection of finishes: Baked enamel, polyurethane
color match.(
)
4. Mullions needed for continuous run
5. Pull Chain Operators available
6. Motor available
9
Screen
18-16 aluminum insect screen in removable frame.
3/4"
3/4"
1 9/16"
A DIM
3 9/16"
B DIM
4" MULLION
4" MULLION
ORDERING INFORMATION
4"
Indicate FINISH in Options Above
QTY.
A DIM
B DIM
SIDE
PROFILE
OPTIONS
NOTE:
MINIMUM SIZE IS 12" X 12"
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
CV-04/ /Rev.
Rev.06/00
00/00
SL-01.9
PART:
6/27/004/22/97
FLAT SKIRT
GALVANIZED
APPLICATION
STEEL
CENTER
RIDGEPIVOT
VENT
CHANNEL TYPE
ADUSTABLE ALUMINUM STORMPROOF BLADE LOUVER
Features
Standard Construction Frame
* Architecturally styled
* All aluminum construction for low maintenance and
high resistance to corrosion
4" deep formed .080 aluminum
Blade
Extruded aluminum.080 J type blade, 45° angle,
spaced 4" center to center
Options
Changes to the basic design of this louver are
available at additional cost. They include:
1. Extended sill
2. A variety of bird or insect screen
3. Selection of finishes: Baked enamel, polyurethane
or anodized.(
)
4. Mullions if needed
(Not for A panel or R panel type)
Screen
Expanded 18-16 aluminum insect screen in removable frame
Finish
Mill
HEADER TYPES
1/4"
NOMINAL
NOMINAL
SILL TYPES
NOMINAL
1/4"
JAMB TYPES
A PANEL
R PANEL
NOMINAL
FLAT FLANGE
SELF FLASHING
FLAT FLANGE
1 1/4" NOMINAL
1 1/2" NOMINAL 1/4" NOMINAL
B DIM
A DIM
BLADE
PROFILE
ORDERING INFORMATION
Circle Panel Type Above
Indicate FINISH in Options Above
QTY.
A DIM
B DIM
SIDE
PROFILE
OPTIONS
NOTE:
MINIMUM SIZE IS 12" X 12"
DATE:
2/20/014/22/97
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 1-800-356-7746
E-mail: info@mpvent.com
CV-04 // Rev.
Rev.06/00
00/00
SL-01.10
PART:
FLAT SKIR
T
ADJUSTABLE
ALUMINUM
APPLICA
TION
STORMPROOF
RIDGE VENT
BLADE
Standard Cupola
Deluxe Cupola
Cupolas
Stamped Cupola
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
DELUXE CUPOLA
Standard Size
Screen
Standard sizes include:
2' wide x 2' long x 2'-0" high
3' wide x 3' long x 3'-0" high
4' wide x 4' long x 4'-0" high
Hardware cloth
18/16 Insect screen
Construction
Options
The sides of the cupola are .080 aluminum with mitered and
welded blades at a 45 degree angle. The tops are made of
.050 aluminum. The cupola is placed on a roof curb of 16
gauge aluminized zinc with minimum of 6" high side.
Optional weather vanes are available
Insulation for the roof curb
Two tone colors
CURB TYPES
Hillside Curb
Peak Curb
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SI-02 / Rev. 2/01
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
STAMPED CUPOLA
Standard Size
Screen
Standard sizes include:
2' wide x 2' long x 2'-0" high
3' wide x 3' long x 3'-0" high
4' wide x 4' long x 4'-0" high
Hardware cloth
18/16 Insect screen
Construction
The sides of the cupola are 26 gauge galvalume or
“precoated material.” The material is then stamped with 2
rows of 4" wide louvers. The tops are made of 22 gauge
material. The cupola is placed on a roof curb of 16 gauge
aluminized zinc with minimum of 6" high side.
Options
Weather vanes are available
Insulation for the roof curb
Two tone colors
CURB TYPES
Hillside Curb
Peak Curb
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SI-03 / Rev. 2/01
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
STANDARD CUPOLA
Standard Size
Screen
Standard sizes include:
2' wide x 2' long x 2'-0" high
3' wide x 3' long x 3'-0" high
4' wide x 4' long x 4'-0 high
2 Mesh Birdscreen
18/16 Insect screen
Construction
Options
The sides of the cupola are constructed of 45 degree fixed
louver blades. Coupolas are designed to be installed on
roof curbs. Please specify type and roof slope when ordering.
Weather vanes
Insulation for the roof curb
Two tone colors
Operable Louver Blades
CURB TYPES
Hillside Curb
Peak Curb
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SI-06 / Rev. 8/01
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
ROOF CURBS…
...used on all types of metal roofing systems and conform to MP’s high standards and specifications which have
been developed, tested and proven over many years.
Rugged, 16 gauge 55% aluminum-zinc coated sheet meets
ASTM A792-89. Corners are mitered and welded water
tight using a siliconized bronze wire for a long lasting and
non-corrosive finish. Welds are finished with a protective
zinc primer. FSK faced rigid board insulation is optional.
water penetration. Hillside mounted curbs have a water
diverting angle to deflect water around the unit. A cricket
can be substituted for the diverter angle if desired. Hillside
mounted curbs can also be constructed utilizing a twopiece design with a separate under-panel diverter to achieve
shingling effect without the need to cut into roof panels.
Design:
Finish:
Curbs are made to match any roof slope and can be either
peak or hillside mounted. Curb corrugations match virtually
any available roof configuration and can be factory welded
into curb skirts or shipped loose for field installation. “R”
panel configurations can be die-formed directly into curb
skirts to reduce the amount of welding and the possibility of
Curbs are supplied with a 55% aluminum-zinc finish and
can be factory painted to match almost any color.
Roof curbs manufactured by Metallic Products for the metal
roofing market are in accordance with the highest design requirements and specifications.
Roof curbs are constructed of 16 gauge galvalume sheet to
provide the ultimate in strength for any roof-top accessory
including A/C units, fans, skylights, refrigeration units, pipes,
stacks, etc...
Curbs also provide a level mounting surface for mechanical
equipment to insure their long life and additionally provide
weather tightness by utilizing the curbs integral flange to mesh
with the roof panels. Curbs can mesh with any metal roof panel
and are made to match specified roof slope either hillside or peak
mounted. Standard diverter angles keep water away from equipment and crickets are available as an option.
Curbs can be insulated to prevent energy loss and can also be
factory painted to match any metal roof color to perfectly blend
in to any architectural application.
Construction:
Ordering:
When ordering, please indicate size, roof panel type,
whether or not insulated, and roof slope. Convenient order
forms available upon request.
7777 Hollister Rd Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
RC-01 / Rev. 2/01
CL O
F MA
JOR
2 3⁄4" 2 3
RIB
⁄4"
END CAPS – RIB PROFILE
ROOF CURB
NOTCHED FOR PANEL RIBS
Note: Sealant Tape Must Be Applied
to All Four Sides
3"
NOTE:
Field Notch Skirt for
Lower Edge Ribs.
END CAP
(OVER PANEL)
SEALANT TAPE
RIBBED ROOF PANEL
PREPARED FOR CURB
11⁄2"
CURB DIM. O/D
OPENING DIM.
CURB
OPENING
11⁄2"
Structure Not by M.P.
SEALANT
TAPE
LOWER EDGE DETAIL
SIDE DETAIL
ROOF PANEL
11⁄2"
4"
SEALANT TAPE
3" 3"
6"
STD.
Structure Not by M.P.
SECTION THRU ROOF SLOPE
6"
END CAP
(UNDER PANEL)
3"
9"
STD.
Structure Not by M.P.
3"
SECTION @ SIDE
SEALANT TAPE
UPPER EDGE DETAIL
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
PART:
9/95
INSTALLATION
INSTRUCTIONS
ROOF CURB
MPD-25
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
ROOF CURBS
WHY A ROOF CURB AND NOT A SIMPLE ROOF PENETRATION?
Let’s start with a definition of what a roof curb is:
A roof curb is a structure that creates a level surface on a sloped roof for mounting and supporting
roof top equipment while retaining weather tightness.
1)STRUCTURAL STRENGTH: The curb is made of 16GA. welded steel. Each curb can hold
thousands of pounds. Also, the curb is usually supported with a “red iron” package so the curb
becomes part of the structure of the building and not just a cap that sits unsupported on the roof
sheets. Together, the curb and the support form a strength not found by just setting the equipment
on the roof without a curb.
2)WEATHER TIGHTNESS: The sides of the curb become an integral part of the roof itself. The curbs
mesh with the roof sheets to form a weather tight barrier. In other words, the flanges of the curb are
a part of the roof sheets. Also, these curbs have a water diverter angle to shed water around the curb
and away from your rooftop equipment.
3)LEVEL MOUNTING SURFACE: As curb manufacturers, we rarely know what equipment will be
mounted on our curbs. Usually, some type of motorized equipment is used; a fan, an air conditioner,
an exhaust unit, a refrigeration unit, or a ventilator. Almost all motorized equipment is designed to
work from a level mounting surface.
4)INSULATION: Optional 1 1/2" - 3lb density fiberglass insulation
7777 Hollister Rd Houston, Texas 77040 · Phone: 713.856.96964 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
RC-02 / Rev. 2/01
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
FABRICATED METAL BUILDING ROOF CURBS
1 – GENERAL
A – The general conditions and supplemental general conditions of the contract apply to this
section as if completely written herein.
B – The General Contractor shall provide all labor, material and equipment to completely install
fabricated metal roof curbs.
C – Fabricated metal roof curbs shall be used at all roof penetrations including, but not limited to,
HVAC units, skylights, duct openings, pipe penetrations, column penetrations, and exhaust
fans.
2 – PRODUCTS
A – Fabricated metal roof curbs shall be models MP-RC (specify #1 #2, #3, #4, #5, #6 or #7) as
manufactured by:
METALLIC PRODUCTS , 7777 Hollister Road, Houston, Texas 77040, (713) 856-9696.
3–
CONSTRUCTION
A – Curbs shall be constructed of 16 gauge galvanized steel,
(to 10 gauge depending on loading), with fully mitered and
welded corners, integral base plates, factory insulated with
11Ú
2" thick aluminum faced 3 pound density fiberglass insulation,
with water diverter angle.
B – Standard height of curb shall be 8" above finished roof (or as specified).
C – Curbs shall be constructed to match slope of roof and provide a level top surface for mounting
of mechanical equipment.
D – Additional Options
1 – Galvalume Construction
5 – Neoprene Foam Gasket
2 – Aluminum Construction
6 – Extended Base Plate
3 – Treated Nailers
7 – Temporary Cover
4 – Solid Top
4 – INSTALLATION
A – Curbs shall be installed in strict accordance with manufacturers printed instructions and as
detailed on the drawings.
7777 Hollister RdHouston,Texas 77040
RC-03/1 / Rev. 2/01
Phone:713.856.96964
Fax: 713.856.9686
1. 800.356.7746
Email: info@mpvent.co
m
www.mpvent.com
Metallic Products
SLOPE MOUNT, TWO PIECE CONSTRUCTION
ROOF CURB
Shingle Type, Field Located
MP-RC1
Customer:
STANDARD FEATURES
1. 16 gauge galvanized steel shell and baseplate
2. Corners mitered and welded watertight
3. Welds prime painted after fabrication
4. Internal angle reinforcing when specified
5. Water diverter angle
6. 6" minimum height on ridge side
7. 1-1/2" – 3# density insulation when specified
Ship To:
Order No.:
ADDED OPTIONS
1.
2.
3.
MATCH ROOF PANEL______________________
Job No.:
Order Date:
Due Date:
NO. REQ'D
DIM. A
Page ______ of _______
RC-1 / Rev. 2/01
DIM.B
H
L
DIM.C
DIM.D
TAG DESCRIPTION
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
INSTALLATION INSTRUCTIONS for MP-RC1
TWO PIECE CONSTRUCTION TO BE INSTALLED ON
COMPLETED ROOF DECK
A.
1. Using curb ribs as a guide, layout and mark roof openings on completed roof deck as outside curb width by
outside curb length plus 9" for diverter plate.
2. Cut openings in roof panel and install support framing
for roof curb and equipment loads. Support at least two
parallel curb walls. Avoid cantilever sections over 1' in
length.
B.
3. Apply wide tape caulk to diverter plate top sides and
upper edge.
4. Align diverter plate ribs with roof deck ribs and slide
diverter plate beneath roof panel.
5. Fasten diverter plate to roof panel and sub-framing
using suitable fasteners compatible with roof system. A
minimum of four fasteners per side spaced on 3" centers
or less as roof system permits. Fasteners should withstand
a minimum pullout force of 150# each.
C.
6. Apply continuous tape caulk at least 2 -1/2" wide around
remaining roof opening.
7. Position curb so that corrugation on curb flanges mate
on top of corresponding corrugations of roof panel on eave
side of opening.
8. Fasten curb to roof panel and diverter plate in accordance with step 5.
D.
9. Inspect all joints and fasteners in curb flanges. Caulk
diverter plate and roof curb flanges to seal out moisture.
10. Apply a closed cell neoprene strip to top rail of roof
curb before setting a rooftop unit. Equipment should be
fastened directly to curb wall using compatible fasteners.
MP-RC1
Metallic Products
RIDGE MOUNT ROOF CURB
Factory Installed Corrugation
MP-RC2
Customer:
STANDARD FEATURES
1. 16 gauge galvanized steel shell and baseplate
2. Corners mitered and welded watertight
3. Welds prime painted after fabrication
4. Internal angle reinforcing when specified
5. Water diverter angle
6. 6" minimum height on ridge side
7. 1-1/2" – 3# density insulation when specified
Ship To:
ADDED OPTIONS
1.
2.
3.
MATCH ROOF PANEL______________________
Order No.:
Job No.:
Order Date:
Due Date:
NO. REQ'D
DIM. A
Page ______ of _______
RC-2 / Rev. 2/01
DIM.B
DIM.C
H
L
TAG DESCRIPTION
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
INSTALLATION INSTRUCTIONS for MP-RC2
FOR INSTALLATION OVER ROOF PANELS
A.
1. On fully sheeted roof, locate and mark center line of roof
opening on ridge.
2. Using distance from center line to major ribs as a guide,
layout and mark roof opening to curb inside dimensions.
B.
3. Cut out roof opening to I.D. of curb, plus an additional 11/2" of the major ribs on the eave sides of the opening to
allow the curb to seal to flat of roof deck.
4. Install structural support framing for roof curb and
equipment loads beneath roof curb and equipment loads
beneath roof curb walls and flanges around opening. Keep
I.D. clear.
C.
5. Turn roof curb upside down and apply tape caulk to curb
flanges.
6. Press the curb in place on the roof deck. Fasten curb to
support steel through curb flange and roof deck using
suitable fasteners compatible\with roof system. A minimum
of four fasteners per side spaced on 3" centers or less as
roof system permits. Fasteners should withstand a minimum pullout force of 150# each.
D.
7. Seal edge of roof curb flange with silicone caulk to
assure watertight weather seal.
8. Apply a closed cell neoprene strip to top rail of roof curb
before setting a rooftop unit. Equipment should be fastened directly to curb wall using compatible fasteners.
RC-2/2
Metallic Products
RIDGE MOUNT ROOF CURB
No Corrugation
MP-RC3
Customer:
STANDARD FEATURES
1. 16 gauge galvanized steel shell and baseplate
2. Corners mitered and welded watertight
3. Welds prime painted after fabrication
4. Internal angle reinforcing when specified
5. Water diverter angle
6. 6" minimum height on ridge side
7. 1-1/2" – 3# density insulation when specified
Ship To:
ADDED OPTIONS
1.
2.
3.
Order No.:
Job No.:
Order Date:
Due Date:
NO. REQ'D
O.D. DIM.
Page ______ of _______
RC-3 / Rev. 2/01
H
L
TAG DESCRIPTION
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
INSTALLATION INSTRUCTIONS for MP-RC3
RIDGE MOUNT ROOF CURBS
To Be Installed Beneath Roof Deck
A.
1. After building framing is complete, locate roof opening
and install support framing for roof curb and equipment
loads.
2. Set and secure roof curb in place on support framing. At
least two parallel curb walls must be on support framing.
Loads shall not be supported by a cantilever section
exceeding 1' in length.
B.
3. Cut roof panels to fit snugly around curb walls.
4. Apply a wide band of tape caulk to top side of curb
flanges.
5. Install and seal closure strips as required. Press roof
panels into position.
C.
6. Fasten roof panel through curb flanges to support steel
using suitable fasteners compatible with roof system. A
minimum of four fasteners per side spaced on 3" centers
or less as roof system permits. Fasteners should withstand
a minimum pullout force of 150# each.
D.
7. Inspect installation and fasteners. Apply silicone sealant
to seal seams around all sides of curb to assure a watertight seal.
8. Apply a closed cell neoprene strip to top rail of roof curb
before setting a rooftop unit. Equipment should be fastened directly to curb wall using compatible fasteners.
RC-3/2
Metallic Products
SLOPE MOUNT ROOF CURB
Over Panel Installation, Shop Located, Factory
Installed Corrugation
MP-RC4
Customer:
STANDARD FEATURES
1. 16 gauge galvalume steel shell and baseplate
2. Corners mitered and welded watertight
3. Welds prime painted after fabrication
4. Additional reinforcing when specified
5. Water diverter
6. 6" minimum height on ridge side
7. 1-1/2 " 3# density insulation when specified
Ship To:
ADDED OPTIONS
1.
2.
3.
MATCH ROOF PANEL
Order No.:
Job No.:
Order Date:
Due Date:
NO. REQ'D
DIM. A
Page ______ of _______
RC-4 / Rev. 2/01
DIM.B
DIM.C
H
L
TAG DESCRIPTION
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
INSTALLATION INSTRUCTIONS for MP-RC4
FOR INSTALLATION OVER ROOF PANELS
A.
1. On fully sheeted roof, locate and mark center line of roof
opening.
2. Using distance from center line to major ribs as guide,
layout and mark roof opening to curb outside dimensions.
B.
3. Cut out roof opening to O.D. of curb, plus an additional
6" of the major ribs on the ridge side of the opening to
allow the curb's water diverter area to seal to flat of roof
deck.
4. Install structural support framing for roof curb and
equipment loads beneath roof curb walls and flanges
around opening. Keep I.D. clear.
C.
5. Turn roof curb upside down and apply tape caulk to curb
flanges.
6. Press the curb in place on the roof deck. Fasten curb to
support steel through curb flange and roof deck using
suitable fasteners compatible with roof system. A minimum
of four fasteners per side spaced on 3" centers or less as
roof system permits. Fasteners should withstand a minimum pullout force of 150# each.
D.
7. Seal edge of roof curb flange with silicone caulk to
assure watertight weather seal.
8. Apply a closed cell neoprene strip to top rail of roof curb
before setting a rooftop unit. Equipment should be fastened directly to curb wall using compatible fasteners.
RC-4/2
Metallic Products
SLOPE MOUNT ROOF CURB
Shop Located, Shingle Type, Factory Installed
Corrugation
MP-RC5
Customer:
STANDARD FEATURES
1. 16 gauge galvalume steel shell and baseplate
2. Corners mitered and welded watertight
3. Welds prime painted after fabrication
4. Additional reinforcing when specified
5. Water diverter
6. 6" minimum height on ridge side
7. 1-1/2" – 3# density insulation when specified
Ship To:
Order No.:
ADDED OPTIONS
1.
2.
3.
MATCH ROOF PANEL
Job No.:
Order Date:
Due Date:
NO. REQ'D
DIM. A
Page ______ of _______
RC-5 / Rev. 2/01
DIM.B
DIM.C
H
L
TAG DESCRIPTION
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
INSTALLATION INSTRUCTIONS for MP-RC5
ONE PIECE CONSTRUCTION
Must Be installed as Deck is Being Laid
A.
1. As roof sheets are being installed, locate roof curb
opening and install support framing for roof curb and
equipment loads. Support at least two parallel curb walls.
Avoid cantilever sections over 1' in length.
2. Trim and install panels on the left, right and below (eave
side) of roof opening. Take care to keep area of curb I.D.
clear.
3. Apply tape caulk to roof deck around roof opening, 2"
from edge of opening.
B
4. Set curb in place and press flanges into mastic. Curb
should be secured through roof deck to sub-framing using
suitable fasteners compatible with roof system. A minimum
of four fasteners per side spaced on 3" centers or less as
roof system permits. Fasteners should withstand a minimum pullout force of 150# each.
C.
5. Apply sealant tape to leading edge of curb flange and
press ridge side roof panels into position over flange and
corrugation closure ribs. Seam roof panels and secure
through curb flange into support steel as in step 4. Seal
end of corrugation to pre-formed metal rib to prevent
capillary action of moisture.
D.
6. Check tightness of fasteners and curb installation, caulk
perimeter edge of curb and flanges of roof panel to seal
moisture out.
7. Apply a closed cell neoprene strip to top rail of roof curb
before setting a rooftop unit. Equipment should be fastened
directly to curb wall using compatible fasteners.
RC-5/2
Metallic Products
Customer:
SLOPE MOUNT ROOF CURB
No Corrugation, For Over & Under Deck
Installation
MP-RC6
STANDARD FEATURES
1. 16 gauge galvalume steel shell and baseplate
2. Corners mitered and welded watertight
3. Welds prime painted after fabrication
4. Additional reinforcing when specified
5. Water diverting cricket
6. 6" minimum height on ridge side
7. 11/2" – 3# density insulation when specified
Ship To:
ADDED OPTIONS
1.
2.
3.
MATCH ROOF PANEL
(LOOSE RIBS)
Order No.:
Job No.:
Order Date:
Due Date:
FRONT FLANGE UNDER PANEL AND REAR FLANGES OVER PANEL
11⁄2"
DIM. A
9"
CURB O.D.
6"
6"
Insulation
A
CL
Section A-A
Insulated
When
Specified
11⁄2"
6"
DIM. B
CURB O.D.
A
PLAN
Section A-A
Uninsulated
H
L
12
ELEVATION
PITCH
NO.
REQ’D
Page
RC-6 / Rev. 2/01
DIM. A
of
DIM B
H
L
TAG
DESCRIPTION
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
CL O
F MA
JOR
2 3⁄4" 2 3
RIB
⁄4"
END CAPS – RIB PROFILE
ROOF CURB
NOTCHED FOR PANEL RIBS
Note: Sealant Tape Must Be Applied
to All Four Sides
3"
NOTE:
Field Notch Skirt for
Lower Edge Ribs.
END CAP
(OVER PANEL)
SEALANT TAPE
RIBBED ROOF PANEL
PREPARED FOR CURB
1
1 ⁄2"
CURB DIM. O/D
OPENING DIM.
CURB
OPENING
1
1 ⁄2"
Structure Not by M.P.
SEALANT
TAPE
LOWER EDGE DETAIL
SIDE DETAIL
ROOF PANEL
1
1 ⁄2 "
4"
SEALANT TAPE
3" 3"
6"
STD.
Structure Not by M.P.
SECTION THRU ROOF SLOPE
6"
END CAP
(UNDER PANEL)
3"
9"
STD.
Structure Not by M.P.
3"
SECTION @ SIDE
SEALANT TAPE
UPPER EDGE DETAIL
DATE:
TITLE:
7777 Hollister Road
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
PART:
9/95
INSTALLATION
INSTRUCTIONS
ROOF CURB
MPD-25
Metallic Products
SLOPE MOUNT ROOF CURB
Floating Curb w/Sub Framing
MP-RC7
Customer:
STANDARD FEATURES
1. 16 gauge galvalume steel shell and baseplate
2. Corners mitered and welded watertight
3. Welds prime painted after fabrication
4. Internal angle reinforcing when specified
5. 6" minimum height on ridge side
6. 1-1/2" – 3# density insulation when specified
Ship To:
ADDED OPTIONS
1.
2.
3.
Order No.:
Job No.:
Order Date:
Due Date:
NO. REQ'D
DIM. A
Page ______ of _______
RC-7 / Rev. 2/01
DIM.B
H
L
TAG DESCRIPTION
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
Curb Sub Framing Detail
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
ROOF ACCESS HATCHES …
…used on metal roofing systems roofs conform to MP’s high standards and specifications which have been
developed, tested and proven over many years. They provide an excellent value for the user.
Custom Sizes
Security
Virtually any size is available because each hatch is custom manufactured.
Hatches are pad-lockable from either inside or outside.
Roof Panel Configuration
Durable 16 gauge galvalume steel construction. Optional
foil-backed fiberglass insulation available. All welds are
made with bronze wire that will never rust. .080 Aluminum
is available upon request.
Hatch is built-in to roof curb to match roof slope and
corrugations.
Design
Hatch can be manufactured to open in any direction. They
feature gas-charged opening devices and automatic holdopen latch.
Construction
Finish
Long-lasting, heat-fused electrostatic powder factory applied to match any architectural color.
ROOF ACCESS!
Roof hatches manufactured by Metallic Products require no additional roof curb… because they are designed
with the curb built in! M.P.’s roof hatches are built to match
any roof slope and corrugations match virtually any available roof panel. They can be made to match any architectural color with our factory applied electrostatic powder
heat-fused to 16 gauge galvalume steel. They are padlockable from either inside or out and feature gas-charged
opening devices as well as an automatic hold-open latch.
Best of all, they conform to Metallic Product’s high
standards and specifications which have been developed,
tested and proven since 1962.
Call (713) 856-9696 (toll free (800) 356-7746) or fax
(713) 856-9686 for ordering and/or additional information.
When you call, be sure to inquire about Metallic Product’s
many other metal building components; such as louvers,
ventilators, roof curbs, door canopies and specialty items.
7777 Hollister Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
RH-01 / Rev. 2/01
DIMENSIONS AND TECHNICAL DATA
Each roof access hatch is custom manufactured to your specified opening and height dimensions and mounted in
the roof panel of your choice. They are furnished with or without insulation.
FRONT UNDER ROOF PANEL
1 1 ⁄2 "
REAR OVER ROOF PANEL
1 1 ⁄2 "
DIM. A
3"
6"
CURB O.D.
3"
3"
Insulation
4"
Double Handle
Lockset
A
Section A-A
Uninsulated
CL
DIM. C
DIM. B
CURB O.D.
A
Section A-A
Insulated
When
Specified
Guide
PLAN
H
L
12
Stay-Bar
Brace
6" Min.
3"
Lift & Cushion
Cylinder
Piano Hinge
(Cont.)
LONG SECTION
BRACE SECTION
ELEVATION
PITCH
ORDERING INFORMATION
Our customer service representatives are eager to assist you with placing your order, either by telephone, fax or
mail. We have ordering sheets available to simplify your ordering procedures and to ensure the accuracy of your
order. The information needed to complete your order include roof panel, opening length and width, panel width,
roof slope, height, width, hinge location, color, and whether to insulate or not.
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
Metallic Products
Customer:
SLOPE MOUNT ROOF ACCESS HATCH
Shop Located, Shingle Type, Factory Installed
Ribs
MP-RH1
STANDARD FEATURES
1. 16 gauge galvalume steel shell and baseplate
2. Corners mitered and welded watertight
3. Curbs prime painted after fabrication
4. Positive hold-open device
5. Water diverting cricket
6. 6" minimum height on ridge side
7. 11⁄2" – 3# density insulation when specified
8. Gas-charged opening device
Ship To:
Order No.:
ADDED OPTIONS
1.
2.
3.
MATCH ROOF PANEL
Job No.:
Order Date:
Due Date:
FRONT UNDER ROOF PANEL
11⁄2"
REAR OVER ROOF PANEL
11⁄2"
DIM. A
3"
6"
CURB O.D.
3"
3"
Insulation
4"
Double Handle
Lockset
A
Section A-A
Uninsulated
CL
DIM. C
DIM. B
CURB O.D.
A
Section A-A
Insulated
When
Specified
Guide
Stay-Bar
Brace
6" Min.
3"
Lift & Cushion
Cylinder
PLAN
H
L
12
Piano Hinge
(Cont.)
LONG SECTION
BRACE SECTION
ELEVATION
PITCH
NO.
REQ’D
DIM. A
DIM B
DIM C.
H
L
HINGE
LOCATION*
* Hinge may be located on any side. Please indicate RIDGE, EAVE, LEFT or RIGHT.
Page
RH-1 / Rev. 2/01
of
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
TAG
DESCRIPTION
Metallic Products
Customer:
SLOPE MOUNT ROOF CURB
Flat Mounting Flange
MP-RH2
STANDARD FEATURES
1. 16 gauge galvalume steel shell and baseplate
2. Corners mitered and welded watertight
3. Curbs prime painted after fabrication
4. Positive hold-open device
5. Water diverting cricket
6. 6" minimum height on ridge side
7. 11/2" – 3# density insulation when specified
8. Gas-charged opening device specified
Ship To:
Order No.:
ADDED OPTIONS
1.
2.
3.
Job No.:
Order Date:
MATCH ROOF PANEL
(LOOSE RIBS)
Due Date:
FRONT FLANGE UNDER PANEL AND REAR FLANGES OVER PANEL
1
1/2"
11/2"
DIM. A
9"
3"
CURB O.D.
Insulation
3"
4"
Double Handle
Lockset
A
A
Guide
CL
Section A-A
Insulated
When
Specified
Stay-Bar
Brace
6" Min.
Lift & Cushion
L
Cylinder
3"
DIM. B
CURB O.D.
Section A-A
Uninsulated
PLAN
Piano Hinge
(Cont.)
LONG SECTION
BRACE SECTION
H
L
12
ELEVATION
PITCH
NO.
REQ’D
DIM. A
DIM B
H
L
HINGE
LOCATION*
TAG
DESCRIPTION
* Hinge may be locatedon any side. PleaseindicateRIDGE, EAVE, LEFT or RIGHT.
Page
RH-1 / Rev. 2/01
of
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
Metallic Products
Customer:
SLOPE MOUNT ROOF ACCESS HATCH
Shingle Type, Factory Installed Ribs
MP-RH DD
STANDARD FEATURES
1. 16 gauge galvalume steel shell and baseplate
2. Corners mitered and welded watertight
3. Curbs prime painted after fabrication
4. Additional reinforcing when specified
5. Water diverter or cricket
6. 6" minimum height on ridge side
7. 11/2" – 3# density insulation when specified
Ship To:
Order No.:
ADDED OPTIONS
1.
2.
3.
MATCH ROOF PANEL
Job No.:
Order Date:
Due Date:
11⁄2"
11⁄2"
DIM. A
3"
3"
6"
CURB O.D.
3"
4"
A
Double Handle
Lockset
CL
DIM. C
DIM. B
A
CURB O.D.
Insulation
Section A-A
Insulated
When
Specified
Section A-A
Uninsulated
3"
Lift & Cushion
Cylinder
H
L
12
6" Min.
PLAN
Piano Hinge
(Cont.)
ELEVATION
PITCH
NO.
REQ’D
DIM. A
LONG SECTION
DIM B
DIM C.
H
L
HINGE
LOCATION*
* Hinge may be located on any side. Please indicate RIDGE, EAVE, LEFT or RIGHT.
Page
RH-2 / Rev. 2/01
of
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
TAG
DESCRIPTION
Metallic Products
Customer:
SLOPE MOUNT ROOF CURB
Flat Mounting Flange
MP-RH DD2
STANDARD FEATURES
1. 16 gauge galvalume steel shell and baseplate
2. Corners mitered and welded watertight
3. Curbs prime painted after fabrication
4. Positive hold-open device
5. Water diverting cricket
6. 6" minimum height on ridge side
7. 11/2" – 3# density insulation when specified
8. Gas-charged opening device specified
Ship To:
Order No.:
ADDED OPTIONS
1.
2.
3.
Job No.:
Order Date:
MATCH ROOF PANEL
(LOOSE RIBS)
Due Date:
1
11/2"
1/2"
FRONT UNDER PANEL AND REAR OVER PANEL
Insulation
DIM. A
3"
9"
3"
CURB O.D.
4"
A
Section A-A
Uninsulated
Section A-A
Insulated
When
Specified
CL
Double Handle
Lockset
Lift & Cushion
Cylinder
3"
DIM. B
CURB O.D.
A
H
L
6" Min.
PLAN
12
ELEVATION
LONG SECTION
PITCH
NO.
REQ’D
DIM. A
DIM B
H
L
HINGE
LOCATION*
TAG
DESCRIPTION
* Hinge may be locatedon any side. PleaseindicateRIDGE, EAVE, LEFT or RIGHT.
Page
RH-1 / Rev. 2/01
of
METALLIC PRODUCTS • Houston, Texas 77040
(713) 856-9696 • Fax (713) 856-9686 • Toll Free (800) 356-7746
Piano Hinge
(Cont.)
Personnel Door Canopies
CANOPIES / ICE SHIELDS
Ice Shields
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
PERSONNEL DOOR CANOPIES
...attractive and efficient while eliminating the need and expense of drafting and manufacturing canopies as part
of the building package.
Construction
Finish
Canopies are constructed of 26 gauge material around an
18 gauge galvanized frame. Telescoping channels mount
between girts on the interior of the building. Channels will
accommodate girt spacing of up to 7'6". l/2" threaded rod
connects channels to canopy frame. All hardware necessary for installation is included.
26 gauge galvanized steel or aluminum. Unit can be
painted after assembly to match most metal building colors
to properly accent building trim.
Standard Size
4'0" projection from face of wall, available in 4'6" width for
single doors and 7'6" width for double doors.
Design
Incorporates a flat soffit and an integral gutter drain. Canopy
drains against building to the outside of the door jambs.
Canopy can be installed in conjunction with any panel type
or panel location. Units can be flashed together for continuous applications.
An efficient and practical canopy for personnel
doors ships as a complete unit, ready for installation.
This canopy extends 4' from the wall and comes in two
standard widths: 4'6" for single doors and 7'6" for
double doors. Integral framing is 18 gauge galvanized
steel with telescoping channel for interior of building
for girt spacing up to 7'6". Design incorporates a flat
soffit and an integral gutter drain. Finishes are available in 26 gauge galvanized steel or aluminum and can
be painted before shipment to match any color to
properly accent building trim. Unit comes with all
necessary hardware for mounting. Canopies mount
against any type of wall panel or masonary wall.
7777 Hollister Rd Houston, Texas 77040 · Phone: 713.856.96964 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SI-01 / Rev. 2/01
*
29" TO 34"
BACK TO BACK CLIP 403
GIRT SPACING (2'9" TO 6')
4'6" X 4' CANOPY 38" Center to Center
7'6" X 4' CANOPY 86" Center to Center
CLIP 403
21/ 2"BOLTS TO 402
COL 402 INSIDE
COL 401
CLIP 403
2 - #14 STS TYP
*
GIRT OVER DOOR
DETAIL 1: INSTALL SUPPORT COLUMNS
BUILDING EXTERIOR WALL
CASE 2
CASE 1
9"
UPPER HANGER ROD
WALL PANEL
DRILL 9/16 " HOLE,
SEAL AFTER ERECTION
Seal Before
Tightening Nut
HEX NUTS (2)
HEX NUTS (2)
HEX NUTS (2)
WASHER
BOLT
UPPER HANGER ROD
WASHER
PIPE SLEEVES (2)
COL 402
CANOPY BRACKET
OPTIONAL EXTERIOR
MOUNTING BRACKET
Y WALL)
(MASONAR
PLAN VIEW
DETAIL 3
11/ 2"
Seal
HEX NUTS (2)
DETAIL 2: INSTALL HANGER ROD 404
HANGER ROD 404
NUT AND WASHER
29"
PLAN VIEW
BOLT 405
DETAIL 4: INSTALL LOWER BOLTS 405
NUT
6"
1
ADJUSTING NUTS
CLOSURE AND SEALANT
BETWEEN CANOPY AND
WALL (BY OTHERS
1
/ 2" BOLTS (2)
DOOR JAMB
EXTENSION
HEX NUTS (2)
CLIP 403
GIRT
/ 2" BOLT X 3"
DATE:
DETAIL 6
TITLE:
DETAIL 5: INSTALL CANOPY SUPPORT RODS
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
SI-01.1 / Rev. 3/00
3/29/00
FIELD ERECTION
PROCEDURE
PART:
CANOPY
CP-445
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
Heavy Duty
PERSONNEL DOOR CANOPIES
“High Wind/Snow Loads”
Masonry mount with
optional decorative wall accents
(Inset — metal wall mount)
Up to 140 mph wind speeds and 100 lb snow loads *
Construction
• Economical and attractive overhead protection from
the elements
• Specifically designed for high wind load and heavy
snow load areas
• 24 gauge flat soffit and integral gutter with rear
mounted drains
• 16 gauge galvanized internal frame
• 18 gauge telescoping support channels mount behind
wall panel between girts, mounting clips and fasteners
included
• ½" or ¾" galvanized pipe hangers with adjustable rod
ends
Finishes
• Galvalume steel
• All standard metal building colors available in silicone
polyester, Kynar and powder coated finishes
• Custom color matching
• Single color or two tone (contrasting gutter/ fascia and
soffit)
Options
• Masonry mount (anchors by others)
• Decorative wall accents
• Front mounted drains
Sizes
• Standard sizes for single door (4'-6" X 4'-0") and
double door (7'-6" X 4'-0"). Also available in 3' and 5'
projections
• Can be mulled together for continuous run
applications
Design Specifications
•
•
•
•
Exposure category ‘B’; Importance factor, I = 1.0
Topographic factor, K.zt = 1.0
Wind directionality, k.d. = 0.85
Elevation of canopy no more than 30 ft above ground
* Wind speed and snow load requirements are specified when ordering and may effect installation requirements
7777 Hollister, Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SI-10 / Rev. 9/10
061-1085FinalCanopy:061-1085_MP_Canopy 9/8/2010 10:48 AM Page 2
Canopy Installation Instructions
*Metal Panel Applications*
Canopy Installation Instructions
*Masonry Applications*
Note: Additional Support Columns and Pipe Hangers may be required for larger
Canopies and/or higher wind loads.
Note: Additional Support Columns and Pipe Hangers may be required for
larger Canopies and/or higher wind loads.
Step 1 Install Vertical Support Columns
Step 1 Install Lower Support Bolts
Install vertical support columns to girt framing. (Girt spacing max 6’0”)
1A - Center canopy over door. Mark wall at locations where pre-attached
canopy rafter angle holes meet wall.
1A - Center canopy over door. If necessary, shift canopy towards door knob so that pipe
hangers penetrate in the high or low areas of panel. When the canopy is positioned at
the desired location match drill 9/16” holes through pre-drilled canopy angle holes.
(These holes are aligned with the center of the zee rafter holes used for the pipe hangers at the wall attachment angle of the canopy).
1B - Align centerline of support columns with 9/16” holes drilled in step 1A. and centerline of zee rafters on canopy between girts. Make sure support columns are perpendicular to top and bottom girt. Attach mounting clips to each end of telescoping support
columns with (2) 1/4” X 3/4” bolts and nuts per clip. Slide adjust columns to proper
length in order to fit between girts (6 ft. maximum). Secure columns to girts with (2) 1/4”
X 3/4” bolts and nuts per clip.
1B - Drill holes in masonry and install wall anchors sized to accept 1/2” bolts
and appropriate design for masonry type. ( Note: wall anchors by others )
1C - Insert 1/2” X 3” bolt with washer through canopy angle and into wall anchor.
Step 2 Attach Pipe Hangers to Canopy
2A - Thread 1/2” nut on one end of the pipe hanger rod end, slide on 1/2”
washer and insert into hole on top of canopy rafter.
2B - Secure with 1/2” nuts and washers on underside of rafter.
Step 2 Install Lower Support Bolts
Step 3 Attach Pipe Hangers to Wall
2A - Match drill through previously drilled holes in wall panel through centerline of support columns.
3A - Locate elevation at the point where opposite rod end will penetrate the
wall.
2B - With canopy re-positioned and matching holes in canopy and wall panel aligned,
attach canopy to wall panel and support column using 1/2” X 6” bolt with washer. (use
PVC spacer sleeve if hole in wall panel is in low area of panel) (Typical each side)
Note: before tightening bolts apply sealant at penetration points
3B - Drill holes in masonry and install wall anchors sized to accept 1/2” bolts
and appropriate design for masonry.
3C - Thread rod end into wall anchor.
3D - Attach rod end to pipe hanger with clevis pin.
Step 3 Attach Pipe Hangers to Canopy
Step 4 Adjust Pitch of Canopy
3A - Thread 1/2” nut on the short rod end, slide on 1/2” washer and insert into hole on
top of canopy rafter. Secure with 1/2” nuts and washers on underside of rafter. ( Typical
for each pipe hanger assy. )
4A - Adjust pipe hanger yoke ends, and/or short rod end at rafter, so the
canopy slopes back toward wall 1/2” to 1” ( for rear mounted drains ).
Step 4 Attach Pipe Hangers to Wall
4A - Locate the elevation at the point where long rod end will penetrate the wall ( adjust
angle of pipe hanger to 45 degrees or as close as possible). Drill 9/16” hole through
panel and support columns. Thread 1/2” nut on long rod end and slide on 1/2” washer.
Insert long rod through wall panel and support columns. Secure at support column with
1/2” nuts and washers.( Note: before tightening, apply sealant at penetration under
washer or decorative plate. )
Metal
Wall
Install
PVC Spacer Sleeve
1/2” Flat Washer Nut
or Decorative Plate
1/2” Pipe Hanger
& 1/2” Rod End
Adjustment
(double nut)
Step 5 Adjust Pitch of Canopy
5A - Adjust pipe hanger yoke ends, and/or short rod end at rafter, so the canopy slopes
back toward wall 1/2” to 1” (for rear mounted drains ).
1/2” Pipe Hanger
& 1/2” Rod End
Sealant
Nut & Washer
Support
Columns
Install
#14 STS
Stich Screw
(2 per Overlap)
1/2” X 6”
Hex Bolt
PVC Spacer Sleeve
Drill 9/16” Hole for
Rod Hanger Connection
(Both Sides)
CL
Girt Spacing
6’ Max
Masonry
Wall
Install
1/2” Flat Washer and
Nut or Decorative Plate
1/2” Pipe Hanger
and 1/2” Rod end
Adjustment
(double nut)
CL
Drill 9/16” Hole
for Lower Bolt
Connection
Girt
Wall Anchor
(by Others)
Masonry Wall
1/2” Pipe Hanger
and 1/2” Rod end
Nut & Washer
Wall Anchor
(by Others)
Girt over Door
C
L of Support Channels to
match CL of Canopy Rafters
Support Column
Nut & Washer
Top Girt
Mounting Clip
install w/4 1/4”
Bolts & Nuts
Provided or
4 #14 STS
1/2” X 6” Rod End
w/Nut & Washer
Nut & Washer
1/2” Hex Bolt
and Nut
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
CANOPY ERECTION INSTRUCTIONS - CASE 1
• Install vertical support columns to girt framing. Girt spacing should be between 2í9" and 6'0".
• Locate center of canopy and door. Adjust towards knob so that rod supports pierce wall panel
on high or low flat areas. Mark girts at desired length.
• Attach clip angles 403 to inside bottom of column 401 and to inside top of column 402 with 2 1/
2" bolts each. Insert column 402 inside column 401 (see Detail 1).
• Adjust columns to proper length to fit between girts. Secure 401 and 402 together with 6 #14
•
•
•
•
•
•
•
•
•
•
sts on each column (2 ea fl. & Web). (See detail #1). With columns assembled, drill 9/16"
diameter holes through 402 using holes in 401 flanges as guide.
Locate columns in place back to back exactly 2'-10" apart at bottom (1'-5 1/8" each side of
length of canopy). Attach to girts with 2-#14 sts at each end of column.
Install upper hanger rod 404 (see detail 4).
Using upper holes as guide, locate and drill a 9/16" hole in a wall panel.
Insert long end of rod through wall (from exterior) and through one flange of column. Put one
nut on rod and leave 1 1/2" thread. Place washer insert through inside flange. Place washer
and second nut. Snug tight.
Install lower support bolts 405 (see detail 4).
Using lower holes in column as guide, drill two 9/16" holes in wall panel (3'-0" c/c).
Insert bolt with washer through inside flange, through pipe sleeve, outside flange, 2 hex nuts
and through wall panel. Tighten nut against column. Space last nut snug against inside of wall
panel for low conditions (see detail 3). Add nuts as follows: From exterior, thread one nut tight
against panel with sealant under nut; thread 2nd nut and locate at face of wall panel. This will
position canopy (bolts 3'-0" c/c).
Install canopy to support rods (see detail 5). Thread nut onto upper hanger rod. For high
condition of wall panel (see detail 4), add sealant around bolt. Position canopy so that the two
lower bolts enter holes nearest center with back of canopy resting on bolts. Add washer to
upper rod, insert upper rods thru holes in top of supports beams. Add washer and hex nuts.
Add washer and nuts to bolts.
Raise lower nuts on upper rod until canopy slopes 1⁄2" to 1" towards building. Tighten all nuts.
Finish with closure and sealant by others as recommended.
ERECTION INSTRUCTIONS - CASE-2
•
Locate desired bottom of canopy elevation on door jamb extensions. Measure up 3” and
drill 2 9/16” holes 3’-3” apart (one each jamb) for lower support bolts. (It may be
necessary to drill from exterior).
•
Install vertical support columns for upper hanger rod same as case 1, except center on
holes in door jamb exterior and drill 9/16” holes 2-11⁄2” above holes in door jamb
exterior.
•
•
•
Install upper hanger rod (same as case 1).
Install lower support bolt (see detail 6).
Install canopy to supports (same as case 1).
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SI-01.2 / Rev. 2/01
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
ICE SHIELDS…
…engineered specifically for heavy snow and ice areas and provides protection from dangerous eave ice shear.
Construction
Finish
Fabricated from 10 gauge structural plate.
All welded construction.
G-90 galvanized. Powdercoat painted to match most metal
building colors after fabrication.
Sizes
Design Specifications
Available in single or double door sizes. Standard nominal
projections of 2 ft., 3 ft., and 4 ft.
125 mph, BOCA 96, I=1.0.
40 lb psf Roof Snow and Live Load.
57 lb psf Gravity Snow Load.
7777 Hollister Rd Houston, Texas 77040 · Phone: 713.856.96964 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SI-09 / Rev. 10/01
Perimeter “J” Trim
Ice Shield
A
12
1'-3"
Ice Shield Kit Components:
• Ice Shield (10 Ga.)
• Perimeter “J” Trim (26 Ga.)
• Sheeting Angle (16 Ga.)
• Fasteners (#12 x 1 SDS)
• Sealant Caulk (Clear)
Quantities & lengths of components vary
based on size required.
4
C
Fasteners
B
Special Considerations:
Sheeting Angle
(not shown)
Ice shield wall plates are pre-punched for
fastening to wall framing at predetermined
locations. If hole edge distance on standard ice
shields requires modification to accommodate
special framing, please specify when ordering.
Walk Door
5' Ice Shield - Single Door
Ice shields are provided with stiffening angles
welded to back side of wall plate. To
accommodate block wall installations, additional
mounting holes replace stiffener angles (for flat
surface mounting). Please note this condition
when ordering.
6'45⁄8"
7"-95⁄8"
Perimeter “J” Trim
1'-7 5/8"
A
Ice Shield
Fasteners for block wall mounting are not
provided by Metallic Products.
12
4
C
B
Fasteners
Sheeting Angle
(not shown)
DATE:
8/24/01
TITLE:
7' Ice Shield - Double Door
SI-09.1 / Rev. 08/01
Walk Door
7777 Hollister RD
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
PART:
ICE SHIELD
COMPONENTS
ICE SHIELD
5'-10"
Wall Girt
Nominal Projection (-2")
Support Jamb
(8 x 4 Channel)
Head Trim
2
Support Header
(8 x 4 Channel)
Support Header
8 x 4 Channel
Wall Panel
Support Jamb
(8 x 4 Channel)
1
Ice Shield
A
Walk Door Frame
(5 x 11⁄4")
Sheeting Angle
1'-2"
8 x 21⁄2" Zee
(5 x 11⁄4")
7'-31⁄2"
B
Sheeting Angle
Wall Girt
7'-01⁄2" 3 5⁄8"
7'-3 ⁄2"
1
Wall Girt
#12 SDS
Outline of Ice Shield
Stiffener Angles
(shop welded to
wall plate)
5
C
2
1'-2"
Outline of Ice Shield
Door Frame
Section - A
Single door w/o Subframe
3'-0"
Typical Ice Shield Wall Framing (Single Door)
5'-10"
Wall Girt
Nominal Projection (-2")
1’-3 ⁄4"
7’-2 ⁄4"
(5 x 1 ⁄4")
1
1
Wall Girt
Sheeting Angle
1
7'-0 ⁄2" 3 ⁄8"
Walk Door
Subframe Jambs
1
8x2 ⁄2" Channel
1
(5 x 1 ⁄4")
1
2
1’-3 1⁄4"
Sheeting Angle
Stiffener Angles
(shop welded to
wall plate)
7’-2 1⁄4"
B
Walk Door
Subframe Header
#12 SDS
SubFrame
5
C
1
2
Head Trim
Ice Shield
Outline of Ice Shield
Wall Girt
Support Header
8x4 Channel
Wall Panel
Support Jamb
(8 x 4 Channel)
Support Header (8 x 4 Channel)
A
5
Support Jamb
(8 x 4 Channel)
Door Frame
3'-41⁄4"
Section - A
Single door w/Subframe
Typical Ice Shield Wall Framing (Single Door w/Subframe)
Wall Panel
Framing Note:
Framing shown is based on industry standards for
typical walk door framing on metal buildings. Actual door
and wall conditions may vary.
Support Header
Head Trim
Ice Shield
#12 x 1 SDS
5'-10"
Wall Girt
2
Jamb Trim
1
5 x 11⁄4" Shtg. Angle
Field cut to length &
DATE:
attach to wall girt
5'-6"
Section - B
8/24/01
TITLE:
SINGLE DOOR
FRAMING INST.
Ice Shield wall plate
Section - C
Single door
SI-09.2 / Rev. 08/01
Stiffener Angle
(3-Places)
7'-31⁄2"
#12 x 1 SDS
Wall Panel
7'-01⁄2"
Sill Trim
Support Jamb
8 x 4 Channel
7777 Hollister Rd
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
PART:
ICE SHIELD
5
8'-1 ⁄8"
Wall Girt
Nominal Projection (-2")
Support Header
8 x 4 Channel
Wall Panel
Support Jamb
(8 x 4 Channel)
Head Trim
2
Support Header
(8 x 4 Channel)
Ice Shield
2
Outline of
Ice Shield
1'-65⁄8"
A
1
Support Jamb
(8 x 4 Channel)
5
1'-6 ⁄8"
#12 SDS
B
Walk Door Frame
Sheeting Angle
Sheeting Angle
(5 x 1 ⁄ ")
(5 x 11⁄4")
1
4
7'-3 1⁄2"
7'-31⁄2"
7'-3 1⁄2"
Wall Girt
Wall Girt
8 x 21⁄2" Zee
7'-01⁄2" 3 5⁄8"
Stiffener Angles
(shop welded to
wall plate)
5
C
Door Frame
Section - A
Double door w/o Subframe
6'-0"
Typical Ice Shield Wall Framing (Double Door)
8'-1 ⁄8"
5
Wall Girt
Nominal Projection (-2")
Support Header
(8 x 4 Channel)
2
(5 x 1 ⁄4")
1
7'-0 ⁄2" 3 ⁄8"
4
Sheeting Angle
1
(5 x 1 ⁄ ")
Wall Girt
Walk Door
Subframe Jamb
Walk Door
Subframe Jamb
1
SubFrame
8 x 21⁄2" Channel
7'-2 1⁄4"
7'-77⁄8"
B
Sheeting Angle
7'-21⁄4"
7'-3 1⁄2"
Walk Door
Subframe Header
#12 SDS
Stiffener Angles
(shop welded to
wall plate)
5
C
1'-77⁄8"
Ice Shield
Outline of
Ice Shield
Wall Girt
Support Header
8 x 4 Channel
2
A
Wall Panel
Head Trim
1
Support Header
(8 x 4 Channel)
Support Jamb
(8 x 4 Channel)
5
Support Jamb
(8 x 4 Channel)
Door Frame
6'41⁄4"
Section - A
Double door w/Subframe
Typical Ice Shield Wall Framing (Double Door w/Subframe)
Framing Note:
Wall Panel
Framing shown is based on
industry standards for typical
walk door framing on metal
buildings. Actual door and
wall conditions may vary.
Ice Shield
8'-15⁄8"
#12 x 1 SDS
2
Support Jamb
8 x 4 Channel
Jamb Trim
1
Ice Shield wall plate
7'-95⁄8"
Section - C
Double door
Wall Girt
5 x 11⁄4" Shtg. Angle
Field cut to length &
attach to wall girt
Section - B
7'-31⁄2"
Sill Trim
Stiffener Angle
(5-Places)
7'-01⁄2"
#12 x 1 SDS
Wall Panel
SI-09.3 / Rev. 08/01
Support Header
Head Trim
DATE:
8/24/01
TITLE:
7777 Hollister Rd
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
DOUBLE DOOR
FRAMING INST.
PART:
ICE SHIELD
Standard Building Trim
TRIM / FLASHING
Die Formed Flashing
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
STANDARD FEATURES:
n
n
n
n
Available in running lengths up to 21 ft.
Constructed of 26 gauge material
(see OPTIONS for additional gauges)
Available in Galvalume™, white or standard colors
(see OPTIONS for additional materials/finishes)
Boxed for shipment.
OPTIONS:
Additional metal thicknesses from 14 to 26 gauge
Additional materials/finishes:
– Galvanized
– Aluminum
– Stainless Steel
– Kynar 500™
n
n
STANDARD TRIM ITEMS:
n
Box Gutter
n
n
Sculptured Gutter
n
n
Box Rake Trim
n
n
Sculptured Rake Trim
Downspout Offset
Sculptured Eave Trim
High Side Eave Trim
n
Sill Trim
n
Drip Trim
n
Cap Trim
n
Simple Eave Trim
n
Starter Trim "A" Panel
n
Peak Boxes
n
Corner Trim "R" Panel
n
Transition Trim
n
Corner Boxes
n
Corner Trim "U" Panel
n
Ridge Cap
n
Soffit/Valley Flashing
n
Valley Flashing
n
Die-Formed Flashing
Inside Corner “R” Panel
n
Downspout (straight)
n
n
Downspout (with kickout)
n
n
Downspout Outlet
n
Jamb Trim
n
Head Trim
n
Downspout Elbow
Inside Corner “U” Panel
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: mpv@mpvent.com · www.mpvent.com
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
TRIM PROFILES
BOX RAKE TRIM - RT1
BOX GUTTER - EG1
JAMB TRIM - JT17
PANEL
DEPTH
5 3/8"
OPTIONAL 1" LEG
3/4"
2 1/2"
1/2"
2 3/4"
1"
3/4"
6 3/4"
1 1/2"
4 1/2"
4 1/4"
1 1/2"
2"
3/4"
SCULPTURED GUTTER - EG2
3/4"
1 1/4"
1/2"
5 1/4"
HEAD TRIM - HT18
SCULPTURED RAKE TRIM - RT2
PANEL
DEPTH
5 3/8"
OPTIONAL 1" LEG
3 1/2"
2 3/4"
3 1/8"
3 1/8"
1 3/4"
3/4"
6 9/16"
6 9/16"
1/2"
4 1/2"
3 5/8"
1"
3 5/8"
COLOR
1 1/2"
1/2"
4 1/2"
2"
HEAD TRIM - HT19
SILL TRIM - ST20
DRIP TRM - DT21
1 5/16"
2 3/4"
2 5/8"
2"
1 3/8"
2 1/2"
1/2"
1"
1/2"
1/2"
OPTIONAL DT _ _ _
1 3/4"
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: mpv@mpvent.com · www.mpvent.com
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
TRIM PROFILES
SCULPTURED EAVE TRIM - ET3
CORNER TRIM "R" PANEL - CT6
STARTER TRIM "A" PANEL - ST26
6 5/8"
1/2"
3 3/4"
2"
1 1/4""
COLOR
1 1/8"
3 1/4"
3 5/8"
1"
3 1/2"
1 1/2"
3/4"
1/2"
2"
HIGH SIDE EAVE TRIM - ET4
TRANSITION TRIM - TT27
CORNER TRIM "U" PANEL - CT7
7 3/8"
3 1/8"
3 1/4"
COLOR
3/4"
1/2"
5 1/4"
PANEL
DEPTH
3 1/4"
3 5/8"
1 1/2"
2"
5"
3/4"
3/4"
1/2""
SIMPLE EAVE TRIM - ET5
INSIDE CORNER "R" PANEL - CT8
INSIDE CORNER "U" PANEL -CT9
4"
3"
3"
1 1/4"
3/4"
4"
3"
4"
COLOR
3/4"
3/4"
COLOR
1/2"
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: mpv@mpvent.com · www.mpvent.com
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
TRIM PROFILES
PEAK BOXES
RIDGE CAP -RC22
DOWNSPOUT OUTLET-DS14
11 1/2"
4"
2' - 0"
3 5/8"
CORNER BOXES
4 1/8"
o
DOWNSPOUT ELBOW 45 - DS15
RIDGE CAP - RC23
4"
6 1/2"
4"
1"
2 3/4"
DOWN SPOUT (STRAIGHT) DS12
DOWNSPOUT OFFSET - DS16
VALLEY FLASHING - SV25
4 1/4"
4"
3 3/4"
1"
6"
4"
SPECIFY
DOWN SPOUT (WITH KICKOUT) -DS13
SOFFIT/VALLEY FLASHING - SV24
CAP TRIM - CT26
8 1/8"
2 7/8"
6"
2 7/8"
1/2"
1/2"
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: mpv@mpvent.com · www.mpvent.com
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
DIE FORMED FLASHING
“R” Panel
“M” Panel
Standard Features:
Applications
10 ft. coverage.
“R” Panel and “M” Panel profiles
AZ-55 Galvalume or Polar White
(additional colors available upon request)
Wall-to-Roof Transition Flashing
Ventilator Skirt Flashing
Roof and Wall Penetrations
High-Side Eave Flashing
WALL PANEL
DIE FORM FLASHING
OVER ROOF PANEL
WALL PANEL
ROOF PANEL
DIE FORM FLASHING
OVER ROOF PANEL
DIE FORM FLASHING
OVER ROOF PANEL
WALL PANEL
EAVE STRUT
ROOF PANEL
Wall-to-Roof Flashing
ROOF PANEL
High-Side Eave Flashing
“R” PANEL
“M” PANEL
12 1⁄2"
12 1⁄2"
4"
4"
1 1⁄4"
3
2"
2"
⁄4 "
2"
2"
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SI-05 / Rev. 10/01
METALLIC PRODUCTS
7777 Hollister Road • Houston, TX 77040
(713) 856-9696 Toll: 800-356-7746
E-mail: info@mpvent.com
Roof Jack
Specialty Items
4" & 12" Stamped Louvers
Pipe Flashing
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
ROOF JACKS
Type S
Straight side roof jack, mounted in flat base or customer
panel with or without cap.
TYPE S
NO. REQ’D
DIM.
T
DIM.
H
CAP
Y or N
PANEL
TYPE
PITCH
COLOR
H
T
Type T
Tapered roof jack, mounted in flat base or customer panel
with or without cap.
TYPE T
NO. REQ’D
DIM.
T
DIM.
B
DIM.
H
CAP
Y or N
PANEL
TYPE
PITCH
COLOR
H
T
B
Please confirm dimensions when ordering roof jacks. Roof pitch must be specified.
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com
SI-04 / Rev. 2/01
NOTES:
1. SLATS MAY BE PLACED AT ANY SPACING OR
QUANTITY.
2. DIMENSION IS PER CUSTOMER REQUEST.
3. INSECT SCREEN IS OPTIONAL.
4. COLOR IS OPTIONAL.
5. SLATS ARE FIXED.
CV-04
/ Rev.
AL-05
/ Rev.
2/0100/00
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
4/22/97
12"FLAT SKIRT
APPLICATION
STAMPED
PART:
RIDGE VENT
LOUVER
12-SL
NOTES:
1. SLATS MAY BE PLACED AT ANY SPACING OR
QUANTITY.
2. DIMENSION IS PER CUSTOMER REQUEST.
3. INSECT SCREEN IS OPTIONAL.
4. COLOR IS OPTIONAL.
5. SLATS ARE FIXED.
CV-04
/ Rev.
AL-06
/ Rev.
2/0100/00
DATE:
TITLE:
7777 Hollister Road
Houston, TX 77040
(713) 856-9696 • 1-800-356-7746
E-mail: info@mpvent.com
4/22/97
4" FLAT SKIRT
APPLICATION
STAMPED
PART:
RIDGE VENT
LOUVER
4-SL
L o u v e r s
·
V e n t i l a t o r s
·
T r i m
·
R o o f
C u r b s
·
S p e c i a l t y
I t e m s
PIPE FLASHING
FEATURES:
Provides tight seal to pipe penetrations
n
Performance is unaffected by ice, snow, hail stones, vibration or expansion
and contraction
n
n
n
Heavy duty aluminum alloy base is highly flexiable and corrosion resistant
and is compatible with virtually any roofing material
Stepped cone design easily adapts to any roof pitch
n
Available in 10 sizes to fit pipe diameters from 1/8" - 26"
n
EPDM available in black or grey/ Silicone available in red
n
Optional split-side construction for wrap around applications
ADVANCED OZONE
RESISTANCE tested to
EPDM
SILICONE
70 hours @ 500 pphm
70 hours @ 500 pphm
EPDM or Silicone
HIGH TEMPERATURE
RESISTANCE
tested to.....intermediate
+135ºC (+275ºF)
+260ºC (+500ºF)
continuous
+100ºC (+212ºF)
+225ºC (+437ºF)
-55ºC (-65ºF)
-74ºC (-100ºF)
10 MPa (1450 psi)
5MPa (700 psi)
25%
50%
LOW TEMPERATURE
RESISTANCE tested to
TENSILE STRENGTH
minimum
COMPRESSION SET
maximum.
INSTALLATION:
1. TRIM
2. SLIDE
Trim opening to 20%
Slide down over pipe.
smaller than pipe diameter.
Description
Master Flash
Master Flash
Master Flash
Master Flash
Master Flash
Master Flash
Master Flash
Master Flash
Master Flash
Master Flash
Master Flash
3. FORM
Press down , bending flashing
to fit irregularities. Use large
slot screwdriver to press into
tight angles.
Pipe Size
1/8 ” – ¾”
¼” – 2 ”
1 ¼” – 3 ”
¼” – 4 ”
3” – 6 ”
4” – 7 ”
5” – 9 ”
6” – 11 ”
7” – 13 ”
10 ” – 18 ”
13 ” – 26 ”
Base Dimension
2 ¼”
4 ½”
6”
8”
10 ”
11 ”
12 ”
14 ”
17 ”
25 ”
34 ”
4. SEAL
5. FASTEN
Apply sealant between
Use fasteners to finish sealing.
Master Flash and roofing.
Vendor No.
MINI
#1
#2
#3
#4
#5
#6
#7
#8
#9
Maxi
Net Wt.
.2#
.2#
.3#
.5#
.8#
1#
1.2#
1.6#
2.6#
3.86#
5.12#
7777 Hollister Road Houston, Texas 77040 · Phone: 713.856.9696 · Fax: 713.856.9686 · 1.800.356.7746 · Email: info@mpvent.com · www.mpvent.com