kl vr high output - Columbia Lighting

advertisement
KL VR HIGH OUTPUT
Premium Industrial / 2-Lamp T8, T12
PROJECT INFORMATION
Project Name
Type
Catalog No.
Date
CONSTRUCTION
Heavy steel housing with longitudinal reinforcing
ribs for extra strength. Reflector die-embossed
with transverse ribs for maximum rigidity. Deep Vee
center channel provides 30° crosswise shielding.
Smooth, extruded apertures provide 18% uplight.
FEATURES
•
•
•
•
•
•
•
Available in 4' and 8' lengths
Reflectors have 18% uplight and 30° transverse shielding
Spring loaded turret lampholders
6" lamp spacing
For individual or continuous row mounting
Channel ends double as joiners
Full depth end closures available
CERTIFICATION
All luminaires are built to UL 1598 standards and
bear appropriate UL and cUL or CSA labels. Damp
location labeling is standard. Emergency-equipped
fixtures labeled UL 924.
FINISH
White painted parts are treated with a five stage
phosphate bonding process and finished with a high
reflectance baked enamel.
ELECTRICAL
Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. All ballast
leads extend a minimum of 6" through access
location. NEC/CEC-compliant ballast disconnect is
standard.
ORDERING INFORMATION
KL
–
MODEL
2
–
NO. OF LAMPS IN
CROSS SECTION
KL Premium
Industrial
2 Two
EXAMPLE KL8-296HO-VR-120-GLR
VR
–
EP
–
REFLECTOR TYPE
VOLTAGE
VR Deep V Reflector
Apertured for Uplight
(Not available with
solid top)
120 120V
277 277V
347 347V
SIZE
LAMP TYPE
4 4'
8 8'
48HO 4', T12: 60 Watt
96HO 8', T12: 110 or 95 Watt
96T8HO 8', T8: 86 Watt
BALLAST
EP Electronic T8,
Program Start
For others available, see
Ballast Options.
Use programmed start ballast. Not recommended for use with instant start. For more occupancy/daylight harvesting sensor accessories see Technical section.
1
Page 1/2 Rev. 08/27/14
© 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
OPTIONS
GLR
GMF
EL
BC
Fast Blow Fuse
Slow Blow Fuse
Emergency Battery Pack
Branch Circuit Plug-on Wiring System
(See options section for details.)
PAF Paint After Fabrication
NYC NYC Compliant
NYCU NYC Compliant, Union Label
ACCESSORIES
(ORDER SEPARATELY)
KZT Zip Tee Hanger - 1½" spacer on
T-bar ceiling
KTH Slide Clamp Tong Hanger
S18 18" Stem, canopy and 8° aligner
SS18 18", 45° Swivel Stem & Canopy
KHC 24" Chain Hanging Assembly
KLEC Full Depth End Closure
KLWG4 Wire Guard 4' lg. - 2 required per
8' fixture
OS1360K Occupancy/Daylight sensor kit,
120/277/347V, one relay, 360 Lens,
snap on drop down adaptor, quick
connect wiring1
Note: KLEGG not available with V reflector fixtures
INDUSTRIALS / KL VR HIGH OUTPUT
KL VR HIGH OUTPUT
Premium Industrial / 2-Lamp T8, T12
PHOTOMETRIC DATA
ZONAL LUMEN SUMMARY
Zone
LUMINAIRE DATA
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
KL8-296HO-VR-PAF
KL Industrial
1' × 8' 2-Lamp Industrial with
Apertured PAF “V” Reflector
480-X-LH-TC-P
0.95
F96/HO
8800
252
N/A
0º = 1.26 90º = 1.31
Length: 8.00
Width: 0.88
Height: 0.00
Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Shielding Angle
Spacing Criterion
Luminous Opening
in Feet
3179
5266
9327
11425
635
981
1827
2700
14125
18.1
29.9
53.0
64.9
3.6
5.6
10.4
15.3
80.3
ENERGY DATA
22.5
37.3
66.0
80.9
4.5
6.9
12.9
19.1
100.0
INDOOR CANDELA PLOT
RCR
70
81
77
70
64
59
54
50
47
44
41
80
50 30
80 77
70 65
62 56
55 48
49 42
44 37
40 33
36 30
33 27
30 24
10
74
61
51
43
37
32
28
25
22
20
70
80
73
67
61
56
52
48
45
42
39
70
50 30
77 74
67 63
59 54
53 47
47 41
42 36
38 32
35 29
32 26
30 24
10
72
59
49
42
36
31
28
25
22
20
50
71
62
55
49
44
39
36
33
30
28
50
30
69
58
50
44
38
34
30
27
25
23
10
66
55
46
40
34
30
26
24
24
19
80.3%
Luminaire Efficacy Rating (LER)
IESNA RP-1-1993 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
53
Non-Compliant
$4.53 based on
3000 hrs. and
$0.08 per KWH
AVG. LUMINANCE (Candela/Sq. M.)
COEFFICIENTS OF UTILIZATION (%)
RC
RW
1
2
3
4
5
6
7
8
9
10
Total Luminaire Efficiency
Average Luminance Angle
Luminaire
Test 11299 Test Date 1/8/03
Lumens % Lamp % Fixt.
0
0
55
46
39
33
29
25
22
20
18
16
0
30
40
45
50
55
60
65
70
75
80
85
0.0
22.5
45.0
67.5
90.0
6198
6093
6000
5938
5863
5742
5611
5423
5154
4844
4359
3544
6198
6130
6054
6007
5975
5923
6088
6187
5405
4082
3196
3491
6198
6170
6221
6424
6532
5992
5128
4045
3192
2960
3011
3702
6198
6181
6585
6457
5759
4862
3822
3126
2892
2853
3011
4000
6198
6207
6636
6247
5466
4518
3553
2996
2879
2889
3064
4000
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
DIMENSIONAL DATA
B
A
A
MOUNTING ACCESSORIES
96"
861/16"
2"
2"
11/8"
15/16"
431/32"
48"
B
A
A
2"
15/16" 11/8"
48"
381/16"
2"
A
A
E
E
431/32"
KHC
S18
43/16"
A
E
7/8" Dia. Knockout
2½"
37/8"
A
6"
13¼"
E
KZT
KTH
A: 7/8" Diameter knockout
B: .570" × .656" Strain Relief knockout
E: 11/8" Diameter knockout
NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
Page 2/2 Rev. 08/27/14
© 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
INDUSTRIALS / KL VR HIGH OUTPUT