kl high output - Columbia Lighting

advertisement
KL HIGH OUTPUT
Premium Industrial / 2, 3 or 4-Lamp T8, T12
PROJECT INFORMATION
Project Name
Type
Catalog No.
Date
CONSTRUCTION
FEATURES
Heavy steel housing with longitudinal reinforcing
ribs for extra strength.
•
•
•
•
•
•
•
White painted parts are treated with a five stage
phosphate bonding process and finished with
a high reflectance baked enamel. LSR and M4R
reflectors specular room side, Mill finish aluminum
top surface.
Available in 4' and 8' lengths
Apertured reflectors have 15% uplight
Spring loaded turret lampholders
6" lamp spacing
For individual or continuous row mounting
Channel ends double as joiners
Full depth end closures available
FINISH
ELECTRICAL
Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. All ballast
leads extend a minimum of 6" through access
location. NEC/CEC-compliant ballast disconnect is
standard.
ORDERING INFORMATION
KL
EXAMPLE KL8-296HO-U-EPU-GLR
–
MODEL
SIZE
KL Premium
Industrial
4 4'
8 8'
–
NO. OF LAMPS IN
CROSS SECTION
2 Two
3 Three
4 Four
ACCESSORIES
(ORDER SEPARATELY)
KZT Zip Tee Hanger - 1½" spacer on
T-bar ceiling
KTH Slide Clamp Tong Hanger
S18 18" Stem, canopy and 8° aligner
SS18 18", 45° Swivel Stem & Canopy
KHC 24" Chain Hanging Assembly
KLEC Full Depth End Closure
KLWG4 Wire Guard 4' lg. - 2 required per
8' fixture
KLEGG White Straight Blade Egg Crate
Louver 4' - 2 required per 8' fixture
OS1360K Occupancy/Daylight sensor kit,
120/277/347V, one relay, 360
Lens, snap on drop down adaptor,
quick connect wiring1
CERTIFICATION
All luminaires are built to UL 1598 standards and
bear appropriate UL and cUL or CSA labels. Damp
location labeling is standard. Emergency-equipped
fixtures labeled UL 924.
EP
–
LAMP TYPE
REFLECTOR TYPE
48HO 4', T12: 60
Watt
96HO 8', T12: 110 or
95 Watt
96T8HO 8', T8: 86 Watt
U Apertured Reflector for
Uplight
ST Solid Top (No Uplight)
M4RST Solid Top Reflector
with 95% Reflective
Specular Silver Finish
M4RU Apertured Reflector
with 95% Reflective
Silver Finish
–
OPTIONS
VOLTAGE
U
120
277
347
120V-277V
120V
277V
347V
GLR
GMF
EL
BC
Fast Blow Fuse
Slow Blow Fuse
Emergency Battery Pack
Branch Circuit Plug-on Wiring
System (See options section
for details.)
PAF Paint After Fabrication
NYC NYC Compliant
NYCU NYC Compliant, Union Label
BALLAST
EP Electronic,
Program Start
For others available,
see Ballast Options.
Use programmed start ballast. Not recommended for use with instant start. For more occupancy/daylight harvesting sensor accessories see Technical section.
1
Page 1/2 Rev. 08/27/14
© 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
INDUSTRIALS / KL HIGH OUTPUT
KL HIGH OUTPUT
Premium Industrial / 2, 3 or 4-Lamp T8, T12
PHOTOMETRIC DATA
ZONAL LUMEN SUMMARY
Zone
LUMINAIRE DATA
0-30
0-40
0-60
0-90
90-120
90-130
90-150
90-180
0-180
KL8-296HO-U
KL Industrial
1' × 8' 2-L High Output Industrial
w/White PAF Apertured Reflector
480-X-TC-P
0.95
F96T12/CW/HO
8800
252
N/A
0º = 1.26 90º = 1.26
Length: 8.00
Width: 1.02
Height: 0.00
Ballast
Ballast Factor
Lamp
Lumens per Lamp
Watts
Shielding Angle
Spacing Criterion
Luminous Opening
in Feet
3182
5250
9612
12738
535
780
1508
2364
15102
18.1
29.8
54.6
72.4
3.0
4.4
8.6
13.4
85.8
ENERGY DATA
21.1
34.8
63.6
84.3
3.5
5.2
10.0
15.7
100.00
INDOOR CANDELA PLOT
RCR
70
90
81
74
67
62
57
53
49
46
43
80
50 30
86 82
74 68
65 58
57 49
51 43
45 38
41 34
37 30
34 27
31 25
10
78
63
52
44
37
32
28
25
22
20
70
86
78
71
64
59
54
50
47
44
41
70
50 30
82 79
71 66
62 56
55 48
49 42
44 37
40 33
36 29
33 27
31 24
10
76
61
51
43
36
32
28
25
22
20
50
76
66
58
51
46
41
37
34
31
29
50
30
73
62
52
45
40
35
31
28
25
23
10
71
58
48
41
35
30
27
24
21
19
85.8%
Luminaire Efficacy Rating (LER)
IESNA RP-1-1993 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
57
Non-Compliant
$4.21 based on
3000 hrs. and
$0.08 per KWH
AVG. LUMINANCE (Candela/Sq. M.)
COEFFICIENTS OF UTILIZATION (%)
RC
RW
1
2
3
4
5
6
7
8
9
10
Total Luminaire Efficiency
Average Luminance Angle
Luminaire
Test 10244 Test Date 1/8/03
Lumens % Lamp % Fixt.
0
0
59
49
41
34
30
26
23
20
18
16
0
30
40
45
50
55
60
65
70
75
80
85
0.0
22.5
45.0
67.5
90.0
5457
5359
5283
5223
5143
5037
4889
4694
4428
4062
3570
2815
5457
5237
5166
5128
5085
5020
4957
5019
5141
4888
4740
4056
5457
5292
5297
5330
5483
5660
5633
5500
5419
5912
4923
3905
5457
5340
5467
5680
5967
5754
5651
5621
6098
6065
3836
4147
5457
5330
5550
5779
5877
5747
5667
5706
6368
5836
3631
4253
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
DIMENSIONAL DATA
MOUNTING ACCESSORIES
96"
861/16"
2"
2"
11/8"
15/16"
431/32"
48"
2"
48"
381/16"
2"
15/16" 11/8"
381/16"
431/32"
KHC
S18
43/16"
61/8"
35/8"
6"
133/8"
KZT
KTH
A: 7/8" Diameter knockout
B: .570" × .656" Strain Relief knockout
E: 11/8" Diameter knockout
NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
Page 2/2 Rev. 08/27/14
© 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
INDUSTRIALS / KL HIGH OUTPUT
Download