GENERAL NOTES: APPROACH SLAB TYPES 1. DESIGN SPECIFICATIONS: TYPE AASHTO, LRFD BRIDGE DESIGN SPECIFICATIONS AND AS SUPPLEMENTED BY THE DESCRIPTION DESIGN MANUAL, PART 4, STRUCTURES. DESIGN IS IN ACCORDANCE WITH THE LOAD AND RESISTANCE FACTOR DESIGN 1 CONCRETE APPROACH SLAB METHOD (LRFD). 2. CONSTRUCTION SPECIFICATIONS AND WORKMANSHIP: CONCRETE APPROACH SLAB WITH 2 PROVIDE MATERIALS AND PERFORM WORK IN ACCORDANCE WITH THE CURRENT VERSION INDEX OF SHEETS SHEET NO. SHEET TITLE 1 GENERAL NOTES - 1 2 GENERAL NOTES - 2 3 TYPE 1 AND TYPE 2 - SECTIONS AND DETAILS 4 TYPE 1 AND TYPE 2 - PLAN 1 5 TYPE 1 AND TYPE 2 - PLAN 2 6 TYPE 1 AND TYPE 2 - PLAN 3 7 TYPE 1 AND TYPE 2 - PLAN 4 SUPERPAVE ASPHALT OVERLAY OF THE PENNSYLVANIA DEPARTMENT OF TRANSPORTATION PUBLICATION 408, AASHTO/AWS/D1.5M/D1.5 2002 - BRIDGE WELDING CODE AND THE CONTRACT SPECIAL ABUTMENT WITH BACKWALL WITH ATTACHED PROVISIONS. (USE AWS/D1.1/D1.1M FOR WELDING NOT COVERED IN 3 AASHTO/AWD/D1.5M/D1.5 2002.) CONCRETE APPROACH SLAB AND NEOPRENE STRIP SEAL DAM 3. ALL DIMENSIONS SHOWN ARE HORIZONTAL, EXCEPT AS NOTED. ABUTMENT WITH BACKWALL WITH ATTACHED TYPE 1 THRU TYPE 4 - TRANSVERSE SECTION 8 WITH ATTACHED BARRIERS INTEGRAL CONCRETE DRAIN TROUGH AND 4 4. DIMENSIONS SHOWN ARE FOR A NORMAL TEMPERATURE OF 68 DEGREES F. TOOTH EXPANSION DAM 5. REINFORCEMENT IN SOME SECTIONS IS NOT SHOWN FOR CLARITY. CONCRETE APPROACH SLAB WITH 5 INTEGRAL ABUTMENT 6. IF NEEDED DETAILS ARE NOT FOUND IN THIS STANDARD A SPECIAL SUBMISSION REQUESTING APPROVAL FOR SPECIFIC DETAILS MUST BE MADE TO THE CHIEF BRIDGE ENGINEER. NOTE: ASPHALT OVERLAY IS NOT PERMITTED ON APPROACH SLAB TYPES 1, 3, 4 AND 5. MATERIAL NOTES: 1. PROVIDE THE FOLLOWING CONCRETE CLASS: 9 TYPE 1, 2 AND 4 - DETAILS 1, 2 AND 3 10 TYPE 1 AND TYPE 2 - DETAIL 4 11 TYPE 1 AND TYPE 2 - DETAIL 5 12 TYPE 1 AND TYPE 2 - DETAIL 6 13 TYPE 1 AND TYPE 2 - DETAIL 7 14 TYPE 1 AND TYPE 2 - DETAIL 8 15 TYPE 1 AND TYPE 2 - DETAIL 9 16 TYPE 1 AND TYPE 2 - DETAIL 10 17 TYPE 1 AND TYPE 2 - DETAIL 11 18 TYPE 1 AND TYPE 2 - DETAIL 12 19 TYPE 3 - PLAN 1 AND SECTION 20 TYPE 3 - PLAN 2 21 TYPE 3 - PLAN 3 22 TYPE 3 AND TYPE 5 - DETAILS 13, 14 AND 15 23 TYPE 5 - DETAILS 16, 17 AND 18 24 TYPE 3 - DETAILS 19 AND 20 25 TYPE 3 - DETAILS 21 AND 22 26 TYPE 4 - PLAN 1 AND SECTION 27 TYPE 4 - PLAN 2 28 TYPE 4 - PLAN 3 29 TYPE 4 - DETAIL 23 30 TYPE 4 - DETAIL 24 31 TYPE 4 - DETAIL 25 32 TYPE 4 - DETAIL 26 33 TYPE 4 - DRAIN TROUGH DETAILS 1 34 TYPE 4 - DRAIN TROUGH DETAILS 2 35 TYPE 5 - PLAN AND SECTION PROVIDE CLASS A CEMENT CONCRETE IN SUPPORT PEDESTALS BELOW THE BRIDGE SEAT CONSTRUCTION JOINT FOR TYPE 4 APPROACH SLAB. PROVIDE CLASS AA CEMENT CONCRETE IN APPROACH SLAB TYPES 1, 2 AND 4, SLEEPER SLABS, BARRIERS, SUPPORT PEDESTALS ABOVE THE BRIDGE SEAT CONSTRUCTION JOINT AND DRAIN TROUGH. PROVIDE CLASS AAAP CEMENT CONCRETE IN APPROACH SLAB TYPES 3 AND 5. A HIGHER CLASS OF CONCRETE MAY BE SUBSTITUTED FOR A LOWER CLASS OF CONCRETE AT NO ADDITIONAL COST TO THE DEPARTMENT. 2. REINFORCEMENT STEEL: PROVIDE GRADE 60 DEFORMED REINFORCING BARS THAT MEET THE REQUIREMENTS OF ASTM A615, ASTM A996, OR A706. DO NOT WELD REINFORCEMENT BARS UNLESS SPECIFIED. DO NOT USE RAIL STEEL A996 IN BARRIERS OR WHERE BENDING OR WELDING OF REINFORCEMENT BARS IS INDICATED. EPOXY COAT ALL REINFORCEMENT BARS. PROVIDE MINIMUM LAP AND EMBEDMENT LENGTH FOR REINFORCING BARS IN ACCORDANCE WITH BC-736M. 3. FABRICATED STRUCTURAL STEEL: PROVIDE STRUCTURAL STEEL CONFORMING TO AASHTO M270 GRADE 36 [ASTM A709, GRADE 36] UNLESS NOTED OTHERWISE. 4. NEOPRENE COMPRESSION SEALS: PROVIDE MATERIALS AND DETAILS IN ACCORDANCE WITH BC-766M. 5. NEOPRENE STRIP SEAL DAMS: PROVIDE MATERIALS AND DETAILS IN ACCORDANCE WITH BC-767M. 6. TOOTH EXPANSION DAMS: PROVIDE MATERIALS AND DETAILS IN ACCORDANCE WITH BC-762M. RC-12M BACKFILL AT STRUCTURES RC-20M CONCRETE PAVEMENT JOINTS BC-788M TYPICAL WATERPROOFING AND EXPANSION DETAILS RC-24M PAVEMENT RELIEF JOINT BC-799M MECHANICALLY STABILIZED EARTH RETAINING WALLS RC-30M SUBSURFACE DRAINS BD-601M CONCRETE DECK SLAB RC-50M GUIDE RAIL TO BRIDGE BARRIER TRANSITIONS BD-610M PA BRIDGE BARRIER THRIE-BEAM TO VERTICAL WALL BRIDGE BD-611M CONCRETE DIAPHRAGM DETAILS BD-615M PA HT BRIDGE BARRIER BD-617M PA TYPE 10M BRIDGE BARRIER BD-618M PA VERTICAL WALL BRIDGE BARRIER CONNECTION BD-621M REINFORCED CONCRETE ABUTMENTS BC-713M PA BRIDGE BARRIER BD-622M R.C. ABUTMENTS WITH BACKWALL BC-735M WALL CONSTRUCTION AND EXPANSION JOINT DETAILS BD-624M R.C. ABUTMENTS WITHOUT BACKWALL BC-736M REINFORCEMENT BAR FABRICATION DETAILS BD-627M MOMENT SLABS BC-739M TYPE F-BRIDGE BARRIER TO GUIDE RAIL TRANSITION BD-655M TYPICAL SUPERSTRUCTURE SECTIONS TOOTH EXPANSION DAM FOR PRESTRESSED CONCRETE BD-656M TYPICAL LONGITUDINAL SECTIONS BD-661M BOX BEAM REINFORCEMENT DETAILS BC-703M BC-708M BC-709M BC-712M BC-762M BC-766M BC-767M BC-775M BARRIER TRANSITION CONNECTION THRIE-BEAM TO PA TYPE 10M BRIDGE BARRIER TRANSITION CONNECTION PA TYPE 10M BRIDGE BARRIER THRIE-BEAM TO PA BRIDGE BARRIER TRANSITION COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY STANDARD BRIDGE APPROACH SLABS AND STEEL BEAM BRIDGES PREFORMED NEOPRENE COMPRESSION SEAL JOINT FOR APPROACH SLABS BD-662M I-BEAM AND PA BULB-TEE BEAM REINFORCEMENT DETAILS AND STEEL BEAM BRIDGES BD-667M INTEGRAL ABUTMENTS MISCELLANEOUS PRESTRESS DETAILS BD-679M STRUCTURE MOUNTED SOUND BARRIER WALLS GENERAL NOTES - 1 NEOPRENE STRIP SEAL DAM FOR PRESTRESSED CONCRETE REFERENCE DRAWINGS RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 1 OF 35 BD-628M INSTRUCTIONS TO DESIGNER NOTES 1. THE INFORMATION SHOWN IN THIS STANDARD IS PROVIDED FOR USE IN THE DEVELOPMENT OF THE CONTRACT DRAWINGS. THE DESIGNER IS RESPONSIBLE FOR THE PRESENTATION OF ALL REQUIRED DETAILS AND NOTES. CONTRACT DRAWING NOTES 15. PLACE ROADWAY INLETS OUTSIDE THE LIMITS OF THE APPROACH SLAB OR SLEEPER SLABS. THE FOLLOWING NOTES ARE TO BE PLACED ON THE CONTRACT DRAWINGS: 16. OPENINGS IN BARRIERS AT BRIDGE / APPROACH SLAB INTERFACE ARE TO BE 1/2" OPEN JOINTS IN ACCORDANCE WITH BC-752M, PLACED PARALLEL TO THE CENTERLINE 1. CONSTRUCT BRIDGE APPROACH SLAB AFTER THE BRIDGE DECK SLAB IS CONSTRUCTED. OF BEARINGS. 2. APPROACH SLAB SKEW ANGLE TO MATCH BRIDGE SKEW ANGLE. BRIDGE SKEW ANGLE MUST 17. OPENINGS IN BARRIERS AT EXPANSION DEVICE (ROADWAY END OF APPROACH SLAB): BE GREATER THAN OR EQUAL TO 45 DEGREES. IF THE BRIDGE SKEW ANGLE IS LESS THAN BRIDGE SKEWS GREATER THAN OR EQUAL TO 75 DEGREES: PROVIDE OPENINGS 45 DEGREES THE DESIGNER MUST DISCUSS ALTERNATE DETAILS WITH THE BRIDGE PARALLEL TO CENTERLINE OF BEARINGS. QUALITY ASSURANCE DIVISION. BRIDGE SKEWS LESS THAN 75 DEGREES: PROVIDE OPENINGS PERPENDICULAR 2. PLACE CONCRETE IN ONE CONTINUOUS OPERATION, UNLESS OTHERWISE INDICATED OR DIRECTED. 3. TRANSVERSE CONSTRUCTION JOINTS ARE NOT PERMITTED IN THE CONCRETE APPROACH TO THE ROADWAY. 3. DESIGNER TO DETERMINE AND SPECIFY THE APPROPRIATE TYPE OF APPROACH SLAB REQUIRED ON THE TS&L DRAWINGS FOR APPROVAL BY PENNDOT. SLAB OR SLEEPER SLAB, UNLESS OTHERWISE INDICATED. 18. PRESTRESSED CONCRETE BEAMS: BEAM NOTCHES: DEPTH OF BEAM NOTCH IS MODIFIED TO ACCOMMODATE THE DEPTH 4. PROVIDE ANY OTHER NOTES AS REQUIRED. OF THE APPROACH SLABS IN ACCORDANCE WITH THE DETAILS SHOWN. SHOW BEAM 4. REFER TO APPROACH SLAB SELECTION CRITERIA TABLE FOR ADDITIONAL INFORMATION. NOTCH DIMENSIONS ON THE CONTRACT DRAWINGS. STRAND PATTERN: STRAIGHT OR DEBONDED STRAND PATTERN IS PREFERRED OVER A 5. DIFFERENT APPROACH SLAB TYPES ARE PERMITTED ON THE SAME BRIDGE. DRAPED STRAND PATTERN TO INSURE PATTERN DOES NOT CONFLICT WITH THE INCREASED BEAM NOTCH DEPTH. DESIGNER TO INSURE THAT THE STRAND PATTERN 6. APPROACH SLABS ARE PERMITTED TO BE USED ON CURVED HORIZONTAL ALIGNMENTS. DESIGNER TO DETERMINE IF THESE DETAILS ARE APPROPRIATE FOR EACH INDIVIDUAL SITUATION. DOES NOT CONFLICT WITH THE BEAM NOTCH. 19. STEEL BEAMS: BEAM NOTCHES: PROVIDE BEAM NOTCH IN ACCORDANCE WITH THE DETAILS SHOWN. SHOW BEAM NOTCH DIMENSIONS ON THE CONTRACT DRAWINGS. 7. CONTRACT DRAWINGS: PROVIDE COMPLETE DETAILS AND NOTES AS REQUIRED. PROVIDE COMPLETE REINFORCEMENT BAR DETAILS AND BAR SCHEDULE. APPROACH SLAB GUIDELINE NOTES PROVIDE FINISHED TOP OF CONCRETE ELEVATIONS AT THE BEGIN AND END OF SLABS AND AT 10 FOOT INTERVALS. PROVIDE ELEVATIONS AT THE BASELINE, GUTTER LINES, AND AT BREAKS IN SLOPES. THE FOLLOWING GUIDELINES ARE PROVIDED IN ORDER TO HELP THE DESIGNER DETERMINE THE APPROPRIATE TYPE OF APPROACH SLAB TO BE SPECIFIED ON THE CONTRACT DRAWINGS. 8. APPROACH SLAB PER RC-23M: DESIGNER TO DISCUSS OPTIONS WITH PENNDOT PRIOR TO TS&L SUBMISSION. APPROACH SLAB DETAILS SHOWN ON RC-23M ARE ONLY PERMITTED WHEN THE BRIDGE IS DESIGNED USING BRADD, UNLESS OTHERWISE DIRECTED. APPROACH SLAB DETAILS ARE NOT REQUIRED ON THE CONTRACT DRAWINGS WHEN THE BRIDGE IS DESIGNED USING BRADD, UNLESS OTHERWISE DIRECTED. 1. BRADD BRIDGES: REFER TO RC-23M, APPROACH SLAB DETAILS ARE NOT REQUIRED ON THE CONTRACT DRAWINGS, UNLESS OTHERWISE DIRECTED. IF THE APPROACH SLAB IS CONSTRUCTED IN ACCORDANCE WITH RC-23M, THE APPROACH SLAB IS A ROADWAY ITEM, UNLESS OTHERWISE DIRECTED. 2. TYPE 1 APPROACH SLAB: PROVIDE TYPE 1 APPROACH SLAB WHEN CONCRETE OR FLEXIBLE PAVEMENT IS SPECIFIED. THE BARRIERS MUST BE CONNECTED TO THE APPROACH SLAB 9. BRIDGE PAY ITEMS: BRIDGE APPROACH SLABS ARE TO BE INCLUDED AS PART OF THE LUMP SUM DIRECTLY OR USE MOMENT SLABS CONNECTED TO THE APPROACH SLAB. STRUCTURE AND SEPARATED INTO INDIVIDUAL ITEMS, UNLESS OTHERWISE DIRECTED. PROVIDE SEPARATE COLUMNS IN THE QUANTITY BLOCK FOR EACH APPROACH SLAB. (APPROACH SLAB AT ABUTMENT 1 / APPROACH SLAB AT ABUTMENT 2) PROVIDE SEPARATE ITEMS AND INDICATE THE APPROXIMATE QUANTITY FOR CONCRETE, REINFORCEMENT, NEOPRENE STRIP SEAL DAMS, TOOTH EXPANSION DAMS, PROTECTIVE 3. TYPE 2 APPROACH SLAB: PROVIDE TYPE 2 APPROACH SLAB WHEN FLEXIBLE PAVEMENT IS SPECIFIED. THE BARRIERS MUST BE CONNECTED TO THE APPROACH SLAB, DIRECTLY OR USE MOMENT SLABS CONNECTED TO THE APPROACH SLAB. COATINGS AND ANY OTHER ITEM THAT MAY BE REQUIRED FOR THE CONSTRUCTION OF THE APPROACH SLAB. COMPRESSION SEALS OR INVERTED V JOINT SEALS, WATERSTOPS, POLYETHYLENE SHEETING, CLOSED CELL NEOPRENE SPONGE, EPOXY BONDING COMPOUND, SAWING AND SEALING JOINTS, BACKER ROD, AND BITUMINOUS PAPER ITEMS ARE INCIDENTAL TO THE APPROACH SLAB CONCRETE. END COVER PLATES, BOLTS, WASHERS AND THREADED INSERTS FOR TYPE 3 AND 5 APPROACH SLABS ARE INCIDENTAL TO THE NEOPRENE STRIP SEAL DAM. STAINLESS STEEL PLATES, RUBBERIZED TROUGH MATERIAL, GALVANIZED STEEL BARS, STAINLESS STEEL SCREWS, NON SHRINK GROUT, STUDS AND ANCHOR BOLTS REQUIRED 4. TYPE 3 APPROACH SLAB: TYPE 3 APPROACH SLABS CONNECTS THE BRIDGE SUPERSTRUCTURE AND BARRIERS WITH THE APPROACH SLAB. PROVIDE TYPE 3 APPROACH SLAB WHEN AN EXPANSION DEVICE IS REQUIRED AND THE DEPARTMENT DIRECTS THE DESIGNER TO RELOCATE THE EXPANSION DEVICE FROM ON THE BRIDGE TO THE END OF THE APPROACH SLAB. DESIGNER TO DETERMINE THE REQUIRED JOINT OPENING AT TIME OF CONSTRUCTION AND THE MOVEMENT REQUIREMENTS OF THE EXPANSION JOINT AT THE END OF THE APPROACH SLAB IN ACCORDANCE WITH THE REQUIREMENTS OF DESIGN MANUAL, PART 4. FOR THE DRAIN TROUGH FOR TYPE 4 APPROACH SLAB ARE INCIDENTAL TO THE TOOTH EXPANSION DAM PAY ITEM. TYPE 5 APPROACH SLABS: PROVIDE STRUCTURAL BACKFILL IN ACCORDANCE WITH RC-12M. SUBBASE MATERIAL NOT REQUIRED. 4. TYPE 4 APPROACH SLAB: PROVIDE TYPE 4 APPROACH SLAB WHEN AN EXPANSION DEVICE IS REQUIRED AND THE ANTICIPATED JOINT MOVEMENT IS OVER 4". EXTEND THE DECK SLAB CONTINUOUS OVER THE BACKWALL TO THE EXPANSION DEVICE SUPPORTED BY AN INTEGRAL DRAIN TROUGH. DESIGNER TO DETERMINE THE REQUIRED JOINT OPENING AT TIME OF CONSTRUCTION 10. ROADWAY PAY ITEMS: SUPERPAVE ASPHALT OVERLAY, ROADWAY PAVEMENT, PAVEMENT RELIEF JOINT, AND THE MOVEMENT REQUIREMENTS OF THE EXPANSION JOINT AT THE END OF THE APPROACH SLAB IN ACCORDANCE WITH THE REQUIREMENTS OF DESIGN MANUAL, PART 4. DUCTILE IRON PIPE, INLETS, EXCAVATION, SUBBASE MATERIAL AND SUBGRADE DRAINS ARE ROADWAY PAY ITEMS. SUBBASE THICKNESS BENEATH THE APPROACH SLABS AND SLEEPER SLABS MUST MATCH THE ROADWAY SUBBASE THICKNESS. 6. TYPE 5 APPROACH SLAB: PROVIDE TYPE 5 APPROACH SLAB WHEN INTEGRAL ABUTMENTS ARE SPECIFIED. DESIGNER TO DETERMINE THE REQUIRED JOINT OPENING AT TIME OF CONSTRUCTION AND THE MOVEMENT REQUIREMENTS OF THE EXPANSION JOINT AT THE END OF THE 11. SUPERPAVE ASPHALT OVERLAY: THE TYPE OF SUPERPAVE ASPHALT MIXTURE DESIGNS PLACED ON TOP OF THE APPROACH SLAB IN ACCORDANCE WITH THE REQUIREMENTS OF DESIGN MANUAL, PART 4, APPENDIX G, SECTION 1.6. APPROACH SLAB MUST MATCH THE TYPE OF SUPERPAVE ASPHALT MIXTURE DESIGNS USED ON THE ADJACENT ROADWAY. DESIGNER TO SPECIFY THE REQUIRED SUPERPAVE ASPHALT MIXTURE DESIGNS, FOR THE WEARING AND BASE COURSES, ON THE CONTRACT PLANS. THE DEPTH OF THE 7. TYPE 3 AND 5 APPROACH SLABS ARE NOT PERMITTED IF MECHANICALLY STABILIZED EARTH (MSE) ABUTMENTS AND/OR RETAINING WALLS ARE SPECIFIED. MSE RETAINING WALLS ARE PERMITTED BEYOND THE END OF THE SLEEPER SLAB. COURSES MUST EQUAL 5". ASPHALT OVERLAY IS ONLY PERMITTED ON TYPE 2 APPROACH SLAB. 8. REFER TO THE DETAILS FOR BEAM DEPTH LIMITATIONS. 12. PAVEMENT SUBGRADE DRAIN: APPROACH SLAB SELECTION CRITERIA TABLE PROVIDE SUBGRADE DRAIN, REFER TO RC-30M, ON THE LOW SIDE OF THE SLEEPER SLAB. APPROACH ROADWAY APPLY A PROTECTIVE COATING FOR REINFORCED CONCRETE SURFACES (PENETRATING SLAB PAVEMENT SEALER, BRIDGE SUPERSTRUCTURE) IN ACCORDANCE WITH PUBLICATION 408, TYPE TYPE 13. PROTECTIVE COATINGS: MINIMUM SKEW ANGLE (DEGREES) ABUTMENT APPROACH SLAB WITH CONNECTED TO BACKWALL? SUPERSTRUCTURE? SUPERPAVE ASPHALT OVERLAY ON APPROACH SLAB? EXPANSION JOINT AT END OF APPROACH SLAB SECTION 1019 TO THE TOP SURFACE OF APPROACH SLAB, EXPOSED SURFACES OF THE SLEEPER SLAB AND TO THE FACE AND TOP SURFACES OF THE BARRIERS. DO NOT PLACE PENETRATING SEALERS ON TOP OF ANY SURFACE THAT RECEIVES ASPHALT OVERLAY. 14. GENERAL INFORMATION: CONCRETE 45 FLEXIBLE 45 FLEXIBLE 45 CONCRETE 45 1 2 N/A NO NO N/A NO YES N/A N/A COMMONWEALTH OF PENNSYLVANIA NEOPRENE DEPARTMENT OF TRANSPORTATION PROVIDE PAVING NOTCH OUT-TO-OUT. THE DETAILS PRESENTED IN THIS STANDARD SHOW A TYPICAL CONCRETE BARRIER. DESIGNER IS RESPONSIBLE TO PROVIDE THE APPROPRIATE DETAILS FOR THE TYPE 3 YES FLEXIBLE 45 CONCRETE 45 YES NO STRIP SEAL BUREAU OF PROJECT DELIVERY OF BARRIER REQUIRED. THE DIAPHRAGM REINFORCEMENT CONNECTING THE TYPE 3 APPROACH SLAB TO THE BRIDGE STRUCTURE WAS DEVELOPED BASED ON A HORIZONTAL LOAD EQUAL TO A FRICTION FACTOR OF 0.60 X DEADLOAD OF APPROACH SLAB DESIGN OF ABUTMENTS AND BEARINGS WITH STRUCTURE SUPPORTED APPROACH SLAB: DESIGNER TO INCLUDE THE FOLLOWING ADDITIONAL VERTICAL LOADS INCURRED FROM THE APPROACH SLAB WHEN DESIGNING THE ABUTMENTS AND BEARINGS. VERTICAL REACTION = 1/2 DEADLOAD OF APPROACH SLAB + PHL-93 LANE LOAD 4 5 FLEXIBLE 45 CONCRETE 45 FLEXIBLE 45 (SEE NOTE 1) TOOTH YES YES NO EXPANSION DAM STANDARD NEOPRENE N/A YES NO STRIP SEAL BRIDGE APPROACH SLABS (IF REQUIRED) REACTION FROM APPROACH SLAB. GENERAL NOTES - 2 PHL-93 LANE LOAD REACTION IS OBTAINED BY TREATING THE BRIDGE APPROACH SLAB AS A SIMPLE BEAM WHICH SPANS FROM STRUCTURE TO SLEEPER SLAB. DESIGNER NOTES: MUST DETERMINE MAXIMUM REACTION BASED ON LENGTH OF THE APPROACH SLAB. 1. SKEW LIMITATIONS PER DESIGN MANUAL, PART 4, APPENDIX G, SECTION 1.2.2 MUST ALSO DESIGN OF BACKWALL WITH BACKWALL SUPPORTED APPROACH SLAB: DESIGNER TO INCLUDE 1/2 DEADLOAD OF THE APPROACH SLAB, MAXIMUM PHL-93 LIVE LOAD REACTION (AXLES PLUS LANE LOAD) AND BRAKING FORCE WHEN DESIGNING THE BACKWALL. DESIGN OF ABUTMENTS: DESIGNER TO INCLUDE 3’-0" LIVE LOAD SURCHARGE IN THE DESIGN OF THE ABUTMENT TO ACCOUNT FOR FUTURE CONDITION WITHOUT APPROACH SLABS (i.e. OMIT APPROACH SLAB DEADLOAD AND LIVE LOAD). BE MET IN ORDER TO USE INTEGRAL ABUTMENTS. 2. IF BRIDGE SKEW ANGLE IS LESS THAN 45 DEGREES THE DESIGNER MUST DISCUSS ALTERNATE RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHEET 2 OF 35 DETAILS WITH THE BRIDGE QUALITY ASSURANCE DIVISION. CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-628M SEAL HEIGHT FACE OF SAW CUT SEAL HEIGHT FACE OF FORMED OPENING PLUS 1" OPENING (TYP ) PLUS 1" TO BE ABRASIVE BLASTED " FOAM JOINT FILLER TOP OF " FOAM JOINT FILLER (TO TO BE REMOVED WITH FORM DECK SLAB DECK SLAB BE REMOVED AFTER PLACEMENT FOR BOTH TYPE 1 AND 3 DESCRIPTION 1. THE JOINT OPENING IS TO BE FORMED BY A TWO-STAGE SAWING WITH FLARED WINGS AND MOMENT SLABS 1 " NEOPRENE SPONGE TO REMAIN TO REMAIN FOR 4 (IN SHOULDER) THE JOINT OPENING SHALL BE FORMED. THE FIRST SAW CUT IS NOTE SEE " CLOSED CELL SHEET NO. APPROACH SLAB SET TO ROADWAY WIDTH FULL WIDTH APPROACH SLAB WITH ATTACHED DESIGNED TO CONTROL CRACKING. THE SECOND SAW CUT IS MADE FORM BOTH TYPE 1 AND 3 9"* PLAN OPERATION WHERE ACCESSIBLE. WHERE ACCESSIBILITY IS LIMITED, 1’-4" NEOPRENE SPONGE, FORMED OPENING APPROACH SLAB " CLOSED CELL JOINT PREPARATION NOTES: THE FOLLOWING NOTES ARE TO BE PLACED ON THE CONTRACT DRAWINGS: FACE OF SAW CUT OR WATERSTOP FORM ON BEAM AND FOAM JOINT FILLER APPROACH SLAB TYPE TYPE 3 - " NOTE " DEPTH VARIES BASED NEOPRENE SPONGE SEE CLOSED CELL WATERSTOP OF APPROACH SLAB CONCRETE ) TYPE 1 - " DESCRIPTION OF PLANS FOR TYPE 1 AND TYPE 2 APPROACH SLABS TOP OF USING A DOUBLE-BLADED WATER-COOLED SAW CAPABLE OF HOLDING BARRIERS WITH FLARED WINGS OR SHORT 2 A TOLERANCE OF 1/16" TO CREATE THE PROPER OPENING FOR THE 5 U-WINGS PREFORMED NEOPRENE COMPRESSION SEAL OR INVERTED V JOINT SEAL. FULL WIDTH APPROACH SLAB WITH ATTACHED 2. WATER BLAST OPENING IMMEDIATELY FOLLOWING SAW CUTTING 3 6 BARRIERS WITH LONG U-WINGS OPERATION TO REMOVE ANY RESIDUAL SLURRY BEFORE IT DRIES. FULL WIDTH APPROACH SLAB WITH ATTACHED 3. THE DEPTH OF THE JOINT OPENING EQUALS THE HEIGHT OF THE SEAL PLUS 1". THE WIDTH OF THE SECOND SAW CUT SHOULD * MEASURED NORMAL BARRIERS WITH FLARED WINGS OR SHORT 4 7 U-WINGS WITH MOMENT SLABS BE ADJUSTED TO ACCOUNT FOR THE CONCRETE SURFACE TO ABUTMENT TEMPERATURE AT THE TIME OF SAWING, SEE MANUFACTURER’S PRODUCT INFORMATION. 9"* WATERSTOP NOTE: DESCRIPTION OF DETAILS FOR 4. BEFORE INSTALLING THE SEAL, ABRASIVE BLAST THE BONDING AN EXPANSION WATERSTOP (TYPE E1 OR E2), IN SURFACES TO THOROUGHLY CLEAN THE JOINT OPENING AND ACCORDANCE WITH BC-735M, MUST BE INSTALLED REMOVE FOREIGN MATERIAL, INCLUDING BROKEN CONCRETE. TYPE 1 AND TYPE 2 APPROACH SLABS USE WATER AND OIL FREE COMPRESSED AIR TO BLOW OUT AT MID-DEPTH OF APPROACH SLAB, OR ABOVE THE RESIDUE FROM THE SEAL GROOVE OPENING. BEAM NOTCH FOR ADJACENT AND SPREAD BOX BEAMS. DETAIL PLACE WATERSTOP TO PROVIDE POSITIVE DRAINAGE DESCRIPTION SHEET NO. 5. PREPARE BONDING SURFACES AND INSTALL JOINT SEAL IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS. TO THE OUTSIDE OF THE STRUCTURE. APPROACH SLAB ADJACENT TO FLEXIBLE 1 9 PAVEMENT 6. DO NOT EXCEED 3% ELONGATION OF THE SEAL, IF STRETCHING TYPE 1 AND 3 TYPE 2 APPROACH SLABS APPROACH SLABS APPROACH SLAB ADJACENT TO CONCRETE OCCURS. 2 9 PAVEMENT APPROACH SLAB ADJACENT TO PAVEMENT 3 9 RELIEF JOINT PAVING NOTCH FORMING DETAILS APPROACH SLAB SUPPORTED ON ABUTMENT NOTE: FOR BACKWALL SUPPORTED APPROACH SLABS (DETAILS 4 AND 5) AND 4 10 BACKWALL WITH NEOPRENE STRIP SEAL DAM TYPE 4 APPROACH SLABS, OMIT THE WATERSTOP AND CLOSED CELL NEOPRENE SPONGE ABOVE THE WATERSTOP. APPROACH SLAB SUPPORTED ON ABUTMENT 5 11 BACKWALL WITH TOOTH EXPANSION DAM HIGHWAY SIDE APPROACH SLAB SUPPORTED ON PRESTRESSED 6 25’-0" PAVEMENT, FLEXIBLE " BRIDGE (TYP.) #5 @ 12" 2 SIDE CLR. 2’-9" SEE DETAILS 12 CONCRETE ADJACENT BOX BEAMS PAY LIMIT: CONCRETE APPROACH SLAB SUPPORTED ON PRESTRESSED PAVEMENT OR PAVEMENT 7 RELIEF JOINT (ROADWAY ITEMS) CONCRETE SPREAD BOX BEAMS AND FULL 13 DEPTH CONCRETE END DIAPHRAGMS 4 THRU 12 SEE DETAILS 1’-4" APPROACH SLAB SUPPORTED ON PRESTRESSED 1, 2 AND 3 8 CONCRETE I-BEAMS AND FULL DEPTH 14 3" CLR. CONCRETE END DIAPHRAGMS (TYP.) APPROACH SLAB SUPPORTED ON STEEL I-BEAMS #5 @ 12" 9 15 #10 @ 9" 3" #6 @ 12" CLR. AND FULL DEPTH CONCRETE END DIAPHRAGMS (BOTH ENDS) APPROACH SLAB SUPPORTED ON ABUTMENT SUBBASE PROVIDE 2 LAYERS OF 4 MIL. 10 CORBEL ADJACENT TO PRESTRESSED CONCRETE (ROADWAY POLYETHYLENE SHEETING ITEM) UNDERNEATH APPROACH SLAB SUBSURFACE DRAIN SLEEPER SLAB APPROACH SLAB SUPPORTED ON ABUTMENT (ROADWAY ITEM)(REFER CORBEL ADJACENT TO PRESTRESSED CONCRETE PAY LIMITS FOR 11 TO INSTRUCTIONS 17 SPREAD BOX BEAMS AND FULL DEPTH CONCRETE BRIDGE APPROACH SLAB QUANTITIES TO DESIGNER NOTES) END DIAPHRAGMS TYPE 1 - CONCRETE APPROACH SLAB APPROACH SLAB SUPPORTED ON ABUTMENT 12 HIGHWAY CORBEL ADJACENT TO STEEL I-BEAMS AND PAY LIMIT 25’-0" (TYP.) ASPHALT OVERLAY BRIDGE 4 THRU 12 FLEXIBLE PAVEMENT SIDE 2 (ROADWAY ITEM) #5 @ 12" (ROADWAY ITEM) CLR. 5" SUPERPAVE " 2’-9" 18 FULL DEPTH CONCRETE END DIAPHRAGMS SIDE SEE DETAILS 16 ADJACENT BOX BEAMS NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. 1’-9" TOTAL THICKNESS SEE DETAIL 1 1’-4" COMMONWEALTH OF PENNSYLVANIA 3" CLR. (TYP.) DEPARTMENT OF TRANSPORTATION #5 @ 12" #10 @ 9" 3" #6 @ 12" PROVIDE 2 LAYERS OF 4 MIL. CLR. BUREAU OF PROJECT DELIVERY (BOTH ENDS) STANDARD SUBBASE (ROADWAY POLYETHYLENE SHEETING ITEM) UNDERNEATH APPROACH SLAB SLEEPER SLAB PAY LIMITS FOR BRIDGE APPROACH SLAB QUANTITIES BRIDGE APPROACH SLABS SUBSURFACE DRAIN (ROADWAY ITEM)(REFER TYPE 1 AND TYPE 2 TO INSTRUCTIONS TO DESIGNER NOTES) SECTIONS AND DETAILS TYPE 2 - CONCRETE APPROACH SLAB WITH SUPERPAVE ASPHALT OVERLAY RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SECTION A-A CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 3 OF 35 BD-628M APPROACH SLAB OR MOMENT SLAB WITH BARRIER ROADWAY PAVEMENT MOMENT SLAB WITH BARRIER 1" FLUSH (LENGTH AS REQUIRED) EXPANSION SHOULDER/ 8’-0" MIN. LANE LINE JOINT 10’-0" BEND LINE OUTSIDE FACE MIN. 5’-0" ADJACENT TO FLEXIBLE PAVEMENT OF BARRIER CURB BARRIER WITH OR CONCRETE PAVEMENT 6’-0" ADJACENT TO PAVEMENT RELIEF JOINT (SEE NOTE 6) CURB BLOCK TIE BARS OR TO MATCH APPROACH TIE BOLTS SLAB DEPTH 6" 10’-0" MIN. (ROADWAY (SEE NOTE 7) 3" ITEM) JOINT (SEE RC-20M) CONSTRUCTION JOINT SUBBASE SHOULDER 8 INLET KEYED CONSTRUCTION MOMENT SLAB DEPTH MIN. " D MOMENT SLAB 8" OF BARRIER CURB OUTSIDE FACE 8’-0" MIN. TRANSITION BARRIER (ROADWAY ITEM) (ROADWAY ITEM) PROVIDE 2 LAYERS OF 4 MIL. (REFER TO RC-20M) POLYETHYLENE SHEETING UNDERNEATH APPROACH SLAB AND MOMENT SLAB TYPE 1 APPROACH SLAB D ADJACENT TO MOMENT SLAB AB SL R PE EE SL 9" @ T. #5 BO & P TO 5" 25’-0" SIDE HIGHWAY SIDE APPROACH SLAB A A P TO " T. 12 BO @ " #5 12 @ 6 # 9" NG VI PA H TC O N 3" WIDTH 8’-0" MIN. BRIDGE WIDTH BRIDGE CURB TO CURB WIDTH C L SLAB WIDTH = MATCH BRIDGE SKEW APPROACH SKEW ANGLE TO #5 @ 12" #10 @ 9" BOT. #8 @ 12" TOP & BOT. OF ABUTMENT #5 @ 12" TOP ROADWAY PAVEMENT APPROACH SLAB SLEEPER SLAB FRONT FACE APPROACH SLAB OR MOMENT SLAB WITH BARRIER ROADWAY #5 @ 12" SHOULDER/ LANE LINE SEAL WITH ASPHALT JOINT SEALANT (AC-20) OUTSIDE FACE MOMENT SLAB DEPTH OF BARRIER TO MATCH APPROACH 5" SUPERPAVE SLAB DEPTH ASPHALT OVERLAY (ROADWAY ITEM) " -6 2’ TIE BARS OR TIE BOLTS 6" MIN. 3" D MOMENT SLAB JOINT (SEE RC-20M) EXTEND JOINT SEAL UP BARRIER 1/2" OPEN JOINT IN BARRIER, FACE IN ACCORDANCE WITH BC-766M. SEE BC-752M FOR DETAILS (TYP). EXTEND WATERSTOP TO OUTSIDE FACE OMIT CAULKING COMPOUND IN AREA OF BARRIER, SEE DETAIL THIS SHEET. (ROADWAY ITEM) PROVIDE 2 LAYERS OF 4 MIL. D OUTSIDE FACE OF BARRIER (REFER TO RC-20M) POLYETHYLENE SHEETING UNDERNEATH APPROACH SLAB AND MOMENT SLAB TYPE 2 APPROACH SLAB ADJACENT TO MOMENT SLAB BARRIER OF SAW CUT FOR JOINT SEAL. CONSTRUCTION JOINT SUBBASE SHOULDER SEE NOTE 4 KEYED CONSTRUCTION 8’-0" MIN. 5" SECTION D-D MOMENT SLAB WITH BARRIER (LENGTH AS REQUIRED) 10’-0" MIN. BEND LINE PLAN 1 TYPE 1 AND TYPE 2 APPROACH SLAB SET TO ROADWAY WIDTH WITH FLARED WINGS AND MOMENT SLABS (IN SHOULDER) NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. OUTSIDE FACE EXTEND JOINT SEAL OF BARRIER UP BARRIER FACE IN ACCORDANCE WITH BC-766M. 2. FOR SECTION A-A, SEE SHEET 3. 3. FOR ADDITIONAL MOMENT SLAB DETAILS REFER TO BD-627M. 4. ELIMINATE THE TIE BARS OR TIE BOLTS ALONG LENGTH INDICATED. COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION " PERM. EXPANSION JOINT BUREAU OF PROJECT DELIVERY 5. PROVIDE PAVING NOTCH OUT TO OUT. FILLER IN ACCORDANCE WITH 6. PROVIDE TYPE 2-SC GUIDE RAIL WITH POSTS AT 3’-1" SPA. ALONG BC-752M OPEN JOINT DETAILS CURB AFTER APPROACH END TRANSITION. 7. INLET TO BE LOCATED SUCH THAT ITS OUTFLOW PIPE MISSES TYPE 2-SC STANDARD POSTS IN GUIDE RAIL TRANSITION. EXTEND WATERSTOP TO BRIDGE APPROACH SLABS OUTSIDE FACE OF BARRIER. PLACE WATERSTOP TO PROVIDE TYPE 1 AND TYPE 2 - PLAN 1 POSITIVE DRAINAGE TO THE OUTSIDE OF THE STRUCTURE. JOINT SEAL AND WATERSTOP RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHEET 4 OF 35 TERMINATION DETAIL CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-628M 10’-0" BEND LINE (SEE NOTE 4) #10 BOT. 1" FLUSH (AS REQUIRED) OUTSIDE FACE E C 8" EXPANSION OF BARRIER BARRIER CURB (ROADWAY ITEM) #5 TOP JOINT CURB MIN. 8" 1" 7" #4 @ 12" ITEM) C 8" INLET (ROADWAY 0" ’10 N. 5) MI TE NO E E (S CURB SHOULDER " 8 C SEE DETAIL C 8" #4 EDGE OF APPROACH SLAB 1" CLR. (TYP.) CONSTR JOINT " AB SL R PE EE SL 9" @ T. #5 BO & P TO (SEE DETAIL B) MIN. 8 OPTIONAL KEYED GUTTER LINE SLAB 6" #5 @ 12" CONSTRUCTION JOINT APPROACH (RAKED FINISH) C SEE NOTE 6. 25’-0" APPROACH SLAB A 5" A 9" NG VI PA H TC NO DETAIL C BRIDGE WIDTH ROADWAY WIDTH CURB TO CURB WIDTH SIDE SIDE (DETAIL AS REQUIRED) C L HIGHWAY BRIDGE #5 @ 12" TOP SKEW ANGLE TO MATCH BRIDGE SKEW #10 @ 9" BOT. APPROACH SLAB SLEEPER SLAB #8 @ 12" TOP & BOT. #5 @ 12" TYPE 1, 3, OR 5 - CONCRETE APPROACH SLAB SEAL WITH ASPHALT 5’-0" ADJACENT TO FLEXIBLE PAVEMENT 8" JOINT SEALANT OR CONCRETE PAVEMENT (AC-20) 6’-0" ADJACENT TO PAVEMENT RELIEF JOINT 7" 1" #4 M AG HR LL AP WA DI CK BA R O #4 @ 12" 8" P TO " T. 12 BO @ " 2 #5 1 @ #6 " -6 2’ (ROADWAY ITEM) 5" 1" CLR. SHOULDER OPTIONAL KEYED EXTEND JOINT SEAL UP BARRIER CONSTRUCTION JOINT FACE IN ACCORDANCE WITH (SEE DETAIL B) BC-766M. EXTEND WATERSTOP TO 5" SUPERPAVE ASPHALT OVERLAY OUTSIDE FACE OF BARRIER, SEE TERMINATION DETAIL ON SHEET 4. (TYP.) CONSTR JOINT APPROACH (RAKED FINISH) SLAB 6" MIN. 1/2" OPEN JOINT IN BARRIER, OUTSIDE FACE OF BARRIER EDGE OF #5 TOP #10 BOT. (AS REQUIRED) 10’-0" MIN. APPROACH SLAB BARRIER E OF SAW CUT FOR JOINT SEAL 1’-4 OMIT CAULKING COMPOUND IN AREA " SEE BC-752M FOR DETAILS (TYP). SUBBASE (ROADWAY ITEM) BEND LINE NOTES TYPE 2 - CONCRETE APPROACH SLAB WITH SUPERPAVE ASPHALT OVERLAY 1. FOR NOTES, SEE SHEETS 1 AND 2. PLAN 2 2. FOR SECTION A-A, SEE SHEET 3. TYPE 1 AND TYPE 2 3. FOR SECTION E-E, SEE SHEET 8. 4. PROVIDE TYPE 2-SC GUIDE RAIL WITH POSTS AT 3’-1" SPA. ALONG FULL WIDTH APPROACH SLAB WITH ATTACHED BARRIERS SECTION C-C CURB AFTER APPROACH END TRANSITION. WITH FLARED WINGS OR SHORT U-WINGS 5. INLET TO BE LOCATED SUCH THAT ITS OUTFLOW PIPE MISSES TYPE 2-SC POSTS IN GUIDE RAIL TRANSITION. 6. TYPE 1 AND TYPE 3 APPROACH SLAB: SUBBASE (ROADWAY ITEM) TYPE 5 APPROACH SLAB: STRUCTURAL BACKFILL, REFER TO RC-12M. SHOULDER/LANE LINE SHOULDER/LANE LINE KEYED CONSTRUCTION JOINT KEYED CONSTRUCTION JOINT " SAW CUT SUPERPAVE ASPHALT SEE NOTE A JOINT SEALING MATERIAL, SEE NOTE A SEE DETAIL JOINT SEALING MATERIAL, " TO OVERLAY 1" " (ROADWAY ITEM) SEE DETAIL COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY CONCRETE CONCRETE JOINT SEALING APPROACH SLAB APPROACH SLAB MATERIAL STANDARD JOINT SEALING DETAIL WITHOUT ASPHALT OVERLAY BRIDGE APPROACH SLABS WITH ASPHALT OVERLAY NOTE A: TYPE 1 AND TYPE 2 - PLAN 2 PROVIDE CONTINUOUS REINFORCEMENT THRU JOINT. MECHANICAL SPLICES ARE PERMITTED AS AN OPTION. DETAIL B RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHEET 5 OF 35 OPTIONAL CONSTRUCTION JOINT AT SHOULDER/LANE LINE CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-628M OUTSIDE FACE OF BARRIER EXPANSION 5’-0" JOINT MIN. 1" FLUSH CURB EXPANSION (ROADWAY JOINT ITEM) BARRIER 1" FLUSH E 5’-0" ADJACENT TO FLEXIBLE PAVEMENT OR CONCRETE PAVEMENT 6’-0" ADJACENT TO PAVEMENT RELIEF JOINT SHOULDER INLET (ROADWAY ITEM) 0" ’10 N. 4) MI TE NO E E (S OPTIONAL KEYED CONSTRUCTION JOINT (SEE DETAIL B, SHEET 5) APPROACH WINGWALL SLAB WITH WITH BARRIER BARRIER 1" FLUSH AB SL R PE EE SL 9" @ T. #5 BO & P TO 25’-0" APPROACH SLAB A 5" JOINT GUTTER LINE BOTTOM OF V-NOTCH APPROACH SLAB BRIDGE WIDTH SIDE SIDE ROADWAY WIDTH HIGHWAY BRIDGE CURB TO CURB WIDTH C L #10 @ 9" BOT. MATCH BRIDGE SKEW SLEEPER SLAB APPROACH SLAB SKEW ANGLE TO #5 @ 12" TOP #8 @ 12" TOP & BOT. #5 @ 12" #5 @ 12" EXPANSION TOP OF BARRIER TOP OF WINGWALL AND CONSTR JOINT 1" PREFORMED BEND LINE CELLULAR POLYSTYRENE A 9" NG VI PA H TC NO M AG HR LL AP WA DI CK BA R O @ #5 #6 @ P TO " T. 12 BO " 12 " -6 2’ WINGWALL SLEEPER SLAB (FAR SIDE OF WINGWALL) SECTION F-F 5" SHOULDER OPTIONAL KEYED EXTEND JOINT SEAL UP BARRIER CONSTRUCTION JOINT FACE IN ACCORDANCE WITH (SEE DETAIL B, SHEET 5) BC-766M. EXTEND WATERSTOP TO OUTSIDE FACE OF BARRIER, SEE TERMINATION DETAIL ON SHEET 4. 1/2" OPEN JOINT IN BARRIER, OMIT CAULKING COMPOUND IN AREA OF SAW CUT FOR JOINT SEAL 5’-0" E MIN. F OUTSIDE FACE 1" FLUSH OF BARRIER EXPANSION F BARRIER SEE BC-752M FOR DETAILS (TYP). JOINT NOTES PLAN 3 TYPE 1 AND TYPE 2 FULL WIDTH APPROACH SLAB WITH ATTACHED BARRIERS WITH LONG U-WINGS 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. FOR SECTION A-A, SEE SHEET 3. 3. FOR SECTION E-E, SEE SHEET 8. 4. INLET TO BE LOCATED SUCH THAT ITS OUTFLOW PIPE MISSES TYPE 2-SC POSTS IN GUIDE RAIL TRANSITION. COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY STANDARD BRIDGE APPROACH SLABS TYPE 1 AND TYPE 2 - PLAN 3 RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 6 OF 35 BD-628M BARRIER 1" FLUSH MOMENT SLAB WITH BARRIER EXPANSION JOINT EXPANSION JOINT 10’-0" MIN. (SEE NOTE 4) OUTSIDE FACE CURB OF BARRIER (ROADWAY ITEM) E H 5’-0" ADJACENT TO FLEXIBLE PAVEMENT OR CONCRETE PAVEMENT 6’-0" ADJACENT TO PAVEMENT RELIEF JOINT (SEE NOTE 6) ROADWAY PAVEMENT MOMENT SLAB WITH BARRIER SHOULDER/ OPTIONAL KEYED (ROADWAY MIN. ITEM) (SEE NOTE 7) CONSTRUCTION JOINT LANE LINE SHOULDER INLET 10’-0" 8’-0" MIN. 8’-0" MIN. OUTSIDE FACE OF BARRIER TIE BARS OR TIE BOLTS (SEE DETAIL B, SHEET 5) 6" H #5 @ 12" AB SL R PE E E SL 9" @ T. #5 BO & P TO #5 @ 12" MIN. LONGITUDINAL SUBBASE SHOULDER JOINT (ROADWAY ITEM) APPROACH SLAB BRIDGE WIDTH MOMENT SLAB ADJACENT TO TYPE 1 APPROACH SLAB A 9" NG VI PA H TC NO P TO " T. 12 BO @ " 2 #5 1 @ #6 M AG HR LL AP WA DI CK A B R O ROADWAY PAVEMENT MOMENT SLAB WITH BARRIER 8’-0" MIN. 3" A 5" CURB TO CURB WIDTH 25’-0" ROADWAY WIDTH SIDE SIDE #10 @ 9" BOT. HIGHWAY BRIDGE SLEEPER SLAB C L #5 @ 12" TOP SKEW ANGLE TO MATCH BRIDGE SKEW #8 @ 12" TOP & BOT. (REFER TO RC-20M) APPROACH SLAB SHOULDER/ " -6 2’ LANE LINE SEAL WITH ASPHALT H JOINT SEALANT (AC-20) OUTSIDE FACE 8’-0" MIN. OPTIONAL KEYED CONSTRUCTION JOINT FACE IN ACCORDANCE WITH (SEE DETAIL B, SHEET 5) BC-766M. EXTEND WATERSTOP TO OUTSIDE FACE OF BARRIER, SEE TERMINATION DETAIL ON SHEET 4. SHOULDER OF BARRIER 5" EXTEND JOINT SEAL UP BARRIER TIE BARS OR 5" SUPERPAVE TIE BOLTS ASPHALT OVERLAY (ROADWAY ITEM) 6" MIN. 1/2" OPEN JOINT IN BARRIER, OMIT CAULKING COMPOUND IN AREA E OF SAW CUT FOR JOINT SEAL H G OUTSIDE FACE G OF BARRIER EXPANSION JOINT BARRIER SEE BC-752M FOR DETAILS (TYP). SUBBASE (ROADWAY ITEM) LONGITUDINAL SHOULDER JOINT (REFER TO RC-20M) (SEE NOTE 4) MOMENT SLAB ADJACENT TO 10’-0" MIN. MOMENT SLAB WITH BARRIER TYPE 2 APPROACH SLAB PLAN 4 SECTION H-H TYPE 1 AND TYPE 2 FULL WIDTH APPROACH SLAB WITH ATTACHED BARRIERS WITH FLARED WINGS OR SHORT U-WINGS WITH MOMENT SLABS APPROACH MOMENT SLAB SLAB WITH WITH BARRIER NOTES BARRIER 1. FOR NOTES, SEE SHEETS 1 AND 2. EXPANSION JOINT 2. FOR SECTION A-A, SEE SHEET 3. (SEE NOTE 4) 3. FOR SECTION E-E, SEE SHEET 8. TOP OF BARRIER 4. PROVIDE THE FOLLOWING JOINT OPENINGS: APPROACH SLAB ADJACENT TO CONCRETE 0R FLEXIBLE PAVEMENT: 1" FLUSH EXPANSION JOINT BEND LINE BOTTOM OF APPROACH SLAB ADJACENT TO PAVEMENT RELIEF JOINT: GUTTER LINE V-NOTCH COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION 1’-0" AND PROVIDE SLIDING PLATE IN ACCORDANCE BUREAU OF PROJECT DELIVERY WITH THE DETAILS SHOWN ON BD-627M. APPROACH SLAB 5. FOR ADDITIONAL MOMENT SLAB DETAILS REFER TO BD-627M. TOP OF WINGWALL BOTTOM OF (IF REQUIRED) MOMENT SLAB 6. PROVIDE TYPE 2-SC GUIDE RAIL WITH POSTS AT 3’-1" SPA. ALONG CURB AFTER APPROACH END TRANSITION. STANDARD 7. INLET TO BE LOCATED SUCH THAT ITS OUTFLOW PIPE MISSES TYPE 2-SC POSTS IN GUIDE RAIL TRANSITION. BRIDGE APPROACH SLABS 1" PREFORMED CELLULAR POLYSTYRENE SLEEPER SLAB (FAR SIDE OF WINGWALL (IF WINGWALL IF WINGWALL IS REQUIRED. EXTEND TO IS REQUIRED) OUTSIDE FACE OF BARRIER IF NOT.) TYPE 1 AND TYPE 2 - PLAN 4 WINGWALL (IF REQUIRED) RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHEET 7 OF 35 SECTION G-G CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-628M BRIDGE WIDTH CURB TO CURB WIDTH SHOULDER ROADWAY WIDTH SHOULDER BARRIER OPTIONAL KEYED BARRIER OPTIONAL KEYED CONSTRUCTION JOINT (SEE DETAIL B, SHEET 5) DESIGNER MUST FULLY DETAIL CONSTRUCTION JOINT 1’-4" - TYPE 1 AND TYPE 4 THE APPROPRIATE BARRIER (SEE DETAIL B, SHEET 5) 1’-6" - TYPE 3 TYPE, LENGTH AND TRANSITION ON THE CONTRACT DRAWINGS OF BARRIER " #5 BARS TYP. 2’-9" IF SPLICE CONSTR JOINT 2 IS REQUIRED CLR. OUTSIDE FACE OUTSIDE FACE #5 @ 12" OF BARRIER (RAKED FINISH) (TYP.) 90 BEND 3" PROVIDE 2 LAYERS OF 4 MIL. POLYETHYLENE SHEETING UNDERNEATH APPROACH SLAB 3’-3" #6 BARS TYP. 4’-3" #7 BARS TYP. CLR. (TYP.) #6 @ 12" - TYPE 1 AND TYPE 4 #7 @ 12" - TYPE 3 PROVIDE 1’-0" GAP IN IF SPLICE WINGWALL SEE DETAIL D (IF REQUIRED) #10 @ 9" - TYPE 1 AND TYPE 4 IS REQUIRED POLYETHYLENE SHEETING #10 @ 6" - TYPE 3 ALONG REAR FACE TO (TYP.) (TYP.) ALLOW FOR DRAINAGE (TYP.) TYPE 1, TYPE 3 OR TYPE 4 CONCRETE APPROACH SLAB WITH ATTACHED BARRIERS BRIDGE WIDTH CURB TO CURB WIDTH SHOULDER ROADWAY WIDTH SHOULDER BARRIER BARRIER DESIGNER MUST FULLY DETAIL OPTIONAL KEYED OPTIONAL KEYED CONSTRUCTION JOINT CONSTRUCTION JOINT (SEE DETAIL B, SHEET 5) (SEE DETAIL B, SHEET 5) TYPE, LENGTH AND TRANSITION ON THE CONTRACT DRAWINGS " IF SPLICE OF BARRIER CONSTR JOINT 2 IS REQUIRED 1’-4" CLR. #5 BARS TYP. 2’-9" OUTSIDE FACE THE APPROPRIATE BARRIER OUTSIDE FACE 1’-9" #5 @ 12" 5" SUPERPAVE TOTAL OF BARRIER ASPHALT OVERLAY THICKNESS (ROADWAY ITEM) SEE DETAIL E (RAKED FINISH) (TYP.) (TYP.) 90 BEND IF SPLICE UNDERNEATH APPROACH SLAB 3" #6 BARS TYP. 3’-3" POLYETHYLENE SHEETING WINGWALL CLR. (TYP.) PROVIDE 2 LAYERS OF 4 MIL. #6 @ 12" #10 @ 9" PROVIDE 1’-0" GAP IN IS REQUIRED POLYETHYLENE SHEETING (IF REQUIRED) SEE DETAIL D (TYP.) (TYP.) ALONG REAR FACE TO ALLOW FOR DRAINAGE (TYP.) NOTES TYPE 2 - CONCRETE APPROACH SLAB WITH 1. FOR NOTES, SEE SHEETS 1 AND 2. ATTACHED BARRIERS AND SUPERPAVE ASPHALT OVERLAY 3" SECTION E-E SEAL WITH ASPHALT RUBBER SEALING COMPOUND OUTSIDE FACE [PUB.408, SECTION 705.4(g)] OUTSIDE FACE OF BARRIER OF BARRIER SEAL WITH AN APPROVED CAULKING COMPOUND 5" SUPERPAVE "x" ASPHALT OVERLAY CHAMFER (TYP.) COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION (ROADWAY ITEM) TOP OF WINGWALL BUREAU OF PROJECT DELIVERY LEVEL STANDARD 1" CLOSED CELL PROVIDE 2 LAYERS OF 4 MIL. NEOPRENE SPONGE POLYETHYLENE SHEETING BRIDGE APPROACH SLABS UNDERNEATH APPROACH SLAB WINGWALL TYPE 1 THRU TYPE 4 - TRANSVERSE SECTION PROVIDE 1’-0" GAP IN BATTER AS REQUIRED POLYETHYLENE SHEETING WITH ATTACHED BARRIERS ALONG REAR FACE TO ALLOW FOR DRAINAGE DETAIL D DETAIL D WITH WINGWALL WITHOUT WINGWALL DETAIL E RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 8 OF 35 BD-628M (TYP.) (TYP.) SLEEPER SLAB STRUCTURE ROADWAY 2’-4" 3" CLR. PAVEMENT 1’-4" 8" 1’-0" 1 #8 @ 12" 1 #5 @ 9" CLASS AA 3" CLR. 1 ITEM) 1 3" CLR. (TYP.) TYPE 1 AND TYPE 4 APPROACH SLAB (WITHOUT OVERLAY) - DETAIL 1 6" MIN. 5’-0" (TYP.) SLEEPER SLAB CEMENT CONCRETE 1 5’-0" 1 1 SUBBASE (ROADWAY 3" #5 @ 9" 6" MIN. SEE NOTE 2 CLR. 1 CLASS AA 1 #8 @ 12" CEMENT CONCRETE 3" ITEM) CLR. SUBBASE 1 SLIDING SURFACE 1’-0" CLR. 3" 1 (ROADWAY REFER TO RC-20M 8" 1 CEMENT 2’-4" SEE NOTE 2 CONCRETE 1’-4" SLIDING SURFACE DEPTH OF TYPE E JOINT 3" CLR. 1’-4" CEMENT CONCRETE 1’-4" CLASS AA (ROADWAY ITEM) 2’-6" CLASS AA ROADWAY SEE DETAIL F 3" CLR. PAVEMENT 2’-6" CONCRETE PAVEMENT PAVEMENT CONCRETE APPROACH SLAB (ROADWAY ITEM) CONCRETE FLEXIBLE PAVEMENT STRUCTURE CONCRETE APPROACH SLAB TYPE 1 AND TYPE 4 APPROACH SLAB - DETAIL 2 END OF APPROACH SLAB ADJACENT (SEE NOTE 3) TO FLEXIBLE PAVEMENT END OF APPROACH SLAB ADJACENT TO CONCRETE PAVEMENT CONCRETE APPROACH SLAB FLEXIBLE PAVEMENT CONCRETE APPROACH SLAB (ROADWAY ITEM) PAVEMENT RELIEF JOINT FOR DETAILS NOT SHOWN REFER TO RC-24M ASPHALT OVERLAY #8 @ 12" 1 #5 @ 9" 1 3" CLR. (TYP.) 6" MIN. 5’-0" (TYP.) SLEEPER SLAB 3" 1 CLR. 1 3" 1 CLR. SUBBASE (ROADWAY #8 @ 12" #5 @ 9" ITEM) 3" CLR. (TYP.) 6" MIN. 6’-0" (TYP.) SLEEPER SLAB TYPE 1 AND TYPE 4 APPROACH SLAB - DETAIL 3 END OF APPROACH SLAB ADJACENT TO TO FLEXIBLE PAVEMENT PAVEMENT RELIEF JOINT FLEXIBLE SLAB PAVEMENT SAWCUT " COMMONWEALTH OF PENNSYLVANIA " TOP OF SUPERPAVE ROADWAY GRADE DEPARTMENT OF TRANSPORTATION ASPHALT OVERLAY ROADWAY GRADE BUREAU OF PROJECT DELIVERY APPROACH SLAB STANDARD " " TO TOP OF CONCRETE JOINT SEALING 5" " " " " TO 1 1 END OF APPROACH SLAB ADJACENT APPROACH PAVEMENT 1 TYPE 2 APPROACH SLAB (WITH OVERLAY) - DETAIL 1 SAWCUT 2’-4" SEE NOTE 2 ROADWAY CEMENT CONCRETE 1’-4" CLASS AA CEMENT CONCRETE 1 CLASS AA 3" 1 ITEM) SLIDING SURFACE 1’-0" 1’-0" CLR. 3" (ROADWAY CLR. SUBBASE CLASS AA 1 1 2’-9" SEE NOTE 2 1’-9" SLIDING SURFACE STRUCTURE ROADWAY PAVEMENT CEMENT CONCRETE PAVEMENT (ROADWAY ITEM) CLR. CEMENT CONCRETE 5" 3" OF APPROACH SLAB CLR. CLASS AA 1’-9" 1’-4" REINFORCED CONCRETE SAWCUT AND SEAL TO WIDTH 3" (ROADWAY ITEM) CONCRETE 2’-6 STRUCTURE 5" SUPERPAVE 1’-0" DEPTH OF 2’-6" SEE DETAIL G PAVEMENT 2’-6" JOINT SEALING MATERIAL MATERIAL NOTES BRIDGE APPROACH SLABS 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. TROWEL SMOOTH AND PLACE 2 LAYERS OF 4 MIL. CONCRETE FLEXIBLE INITIAL SAWCUT " (DEPTH TO APPROACH SLAB PAVEMENT TOP OF CONCRETE APPROACH SLAB) POLYETHYLENE SHEETING AS BOND BREAKER. TYPE 1, 2 AND 4 - DETAILS 1, 2 AND 3 3. USE DETAIL 2 ONLY WHEN LIMITED MOVEMENT (ADJACENT TO ROADWAY) IS ANTICIPATED IN THE ROADWAY OTHERWISE USE DETAIL 3. REFER TO RC-24M FOR ADDITIONAL DETAIL F DETAIL G INFORMATION. RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 9 OF 35 BD-628M JOINT OPENING FOR JOINT SEAL, SEE JOINT PREPARATION NOTES ON SHEET 3. WIDTH OF OPENING SHOULD BE ADJUSTED TO ACCOUNT FOR THE CONCRETE SURFACE TEMPERATURE AT THE TIME OF SAWING. SEE MANUFACTURER’S DATA. BRIDGE APPROACH SLAB GRIND OR TOOL 2’-0"* DECK " CHAMFER CONCRETE ROADWAY GRADE 2’-0"* 1’-3"* 9"* BEAM NOTCH 1’-4" 1’-9" 2’-0" 1’-4" AND HAUNCH 8" MIN. 1’-0" DECK SLAB APPROACH SLAB CONCRETE " " TO PLUS 1". SEE SEE DETAIL H DAM (SEE BC-767M) DEPTH EQUALS TYPE 1 NEOPRENE STRIP SEAL 9"* TYPE 2 1’-3"* HEIGHT OF SEAL BLOCKOUT MANUFACTURER’S DATA LIMITS OF 1" MIN. NOMINAL WIDTH NEOPRENE COMPRESSION SEAL FOR " MOVEMENT CLASSIFICATION, SEE NOTE 3. SEE DETAIL H NOTES OR INCREASED HAUNCH DEPTH " MIN. BOND BREAKER, CONSTR BEAM 2-PLY BIT. PAPER JOINT " CLOSED CELL BRIDGE APPROACH SLAB CONSTR. CLASS AA CEMENT CONCRETE JOINT " CLOSED CELL (TYP) NEOPRENE SPONGE DETAIL H 8"* 4" NEOPRENE SPONGE (NEOPRENE COMPRESSION SEAL) JOINT OPENING FOR JOINT SEAL, SEE JOINT PREPARATION NOTES ON SHEET 3. WIDTH OF OPENING SHOULD BE BACKWALL 4"* (SEE NOTE 2) 1’-8"* ADJUSTED TO ACCOUNT FOR THE CONCRETE SURFACE TEMPERATURE AT THE TIME OF SAWING. SEE MANUFACTURER’S DATA. * MEASURED NORMAL TO ABUTMENT * MEASURED NORMAL TO ABUTMENT BRIDGE APPROACH SLAB OPTIONAL BACKWALL GRIND OR TOOL TYPE 1 APPROACH SLAB (WITHOUT OVERLAY) - DETAIL 4 (SEE NOTE 2) DECK APPROACH SLAB SUPPORTED ON ABUTMENT " CHAMFER CONCRETE ROADWAY GRADE LIMITS OF 1’-2"* 9"* APPROACH SLAB CONCRETE " " TO PLUS 1". SEE MANUFACTURER’S DATA DEPTH EQUALS 2’-0"* HEIGHT OF SEAL BACKWALL WITH NEOPRENE STRIP SEAL DAM 1" MIN. NOMINAL INVERTED V JOINT SEAL FOR " MOVEMENT CLASSIFICATION, SEE NOTE 3. BLOCKOUT SEE DETAIL H NOTES SUPERPAVE ASPHALT NEOPRENE STRIP SEAL DAM (SEE BC-767M) OVERLAY (ROADWAY ITEM) SEE DETAIL J, " MIN. (TYP) 5" DECK SLAB 1’-9" (INVERTED V JOINT SEAL) DETAIL H NOTES 1. DETAIL H SHOWN FOR TYPE 1-STRUCTURE SUPPORTED APPROACH SLABS. 8" BEAM NOTCH OR INCREASED " CLOSED CELL NEOPRENE SPONGE DETAIL H AND HAUNCH 1’-4" MIN. 1’-0" SHEET 11 2. FOR TYPE 1-BACKWALL SUPPORTED AND TYPE 4 APPROACH SLABS, OMIT HAUNCH DEPTH WATERSTOP AND " CLOSED CELL NEOPRENE SPONGE ABOVE WATERSTOP. 3. FOR TYPE 3 APPROACH SLABS, OMIT " CLOSED CELL NEOPRENE SPONGE BEAM BOND BREAKER, CONSTR 2-PLY BIT. PAPER JOINT " CLOSED CELL ABOVE WATERSTOP. BRIDGE APPROACH SLAB CLASS AA CEMENT CONCRETE COMMONWEALTH OF PENNSYLVANIA 8"* DEPARTMENT OF TRANSPORTATION NEOPRENE SPONGE BUREAU OF PROJECT DELIVERY BACKWALL (SEE NOTE 2) STANDARD NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. BRIDGE APPROACH SLABS 2. DESIGNER TO DETERMINE BACKWALL SHAPE, REFER TO * MEASURED NORMAL TO ABUTMENT BD-621M, SHEET 2. 3. USE ONLY APPROVED SEALS, AS LISTED IN BULLETIN 15. TYPE 2 APPROACH SLAB (WITH OVERLAY)- DETAIL 4 APPROACH SLAB SUPPORTED ON ABUTMENT BACKWALL WITH NEOPRENE STRIP SEAL DAM TYPE 1 AND TYPE 2 - DETAIL 4 INSTALL JOINT SEALS TO A UNIFORM DEPTH WITH THE TOP OF THE SEAL FROM" TO" BELOW THE LEVEL (NEOPRENE STRIP SEAL DAM WITH BACKWALL) OF THE CHAMFER. MAKE THE TOP EDGES OF THE CONTACT SURFACES ON BOTH SIDES OF THE SEAL AT THE SAME ELEVATION. RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHEET 10 OF 35 4. FOR FORMING AND WATERSTOP DETAILS, SEE SHEET 3. CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-628M BRIDGE APPROACH SLAB "* SAWCUT * MEASURED NORMAL TO ABUTMENT " JOINT SEALING MATERIAL ROADWAY GRADE 2" DIA HEAT RESISTANT TOOTH EXPANSION SEE DETAIL H, BACKER ROD DAM (SEE BC-762M) 1’-4" DEPTH EQUALS HEIGHT AND HAUNCH COMPRESSION SEAL FOR " MOVEMENT CLASSIFICATION, SEE NOTE 2. MANUFACTURER’S DATA 8" BEAM NOTCH OF SEAL PLUS 1". SEE 1" MIN. NOMINAL WIDTH NEOPRENE " " TO DECK SLAB MIN. 1’-0" SHEET 10 OR INCREASED ITEM) CONCRETE (ROADWAY 9"* 5" SUPERPAVE 1’-3"* ASPHALT OVERLAY DECK LIMITS OF BLOCKOUT " " TO 2’-0"* APPROACH SLAB HAUNCH DEPTH CONCRETE " MIN. BOND BREAKER, CONSTR (TYP) NEOPRENE SPONGE BRIDGE APPROACH SLAB 2-PLY BIT. PAPER JOINT " CLOSED CELL JOINT OPENING FOR JOINT SEAL, SEE JOINT PREPARATION CLASS AA CEMENT CONCRETE BEAM NOTES ON SHEET 3. WIDTH OF OPENING SHOULD BE " CLOSED CELL 8"* ADJUSTED TO ACCOUNT FOR THE CONCRETE SURFACE NEOPRENE SPONGE TEMPERATURE AT THE TIME OF SAWING. SEE MANUFACTURER’S DATA. DETAIL J (NEOPRENE COMPRESSION SEAL) * MEASURED NORMAL TO ABUTMENT BRIDGE APPROACH SLAB "* TYPE 1 APPROACH SLAB (WITHOUT OVERLAY) - DETAIL 5 * MEASURED NORMAL SAWCUT TO ABUTMENT " JOINT SEALING MATERIAL ROADWAY GRADE 2" DIA HEAT RESISTANT BACKER ROD (ROADWAY ITEM) 5" SUPERPAVE " DECK CONCRETE " TO BACKWALL WITH TOOTH EXPANSION DAM ASPHALT OVERLAY APPROACH SLAB SUPPORTED ON ABUTMENT 1’-2"* 9"* OF SEAL PLUS 1". SEE " MIN. NOMINAL INVERTED V JOINT SEAL FOR " MOVEMENT " DEPTH EQUALS HEIGHT LIMITS OF BLOCKOUT " TO 2’-0"* CLASSIFICATION, SEE NOTE 2. MANUFACTURER’S DATA APPROACH SLAB SUPERPAVE ASPHALT TOOTH EXPANSION DAM (SEE BC-762M) CONCRETE OVERLAY (ROADWAY ITEM) SEE DETAIL J " MIN. " CLOSED CELL (TYP) 5" JOINT OPENING FOR JOINT SEAL, SEE JOINT PREPARATION NOTES ON SHEET 3. WIDTH OF OPENING SHOULD BE AND HAUNCH OR INCREASED HAUNCH DEPTH ADJUSTED TO ACCOUNT FOR THE CONCRETE SURFACE 1’-9" 1’-4" BEAM NOTCH TEMPERATURE AT THE TIME OF SAWING. SEE MANUFACTURER’S DATA. DETAIL J 8" MIN. DECK SLAB 1’-0" NEOPRENE SPONGE (INVERTED V JOINT SEAL) DETAIL J NOTES BOND BREAKER, CONSTR BEAM 2-PLY BIT. PAPER JOINT BRIDGE APPROACH SLAB CLASS AA CEMENT CONCRETE 1. DETAIL J SHOWN FOR TYPE 2-STRUCTURE SUPPORTED APPROACH SLABS. 2. FOR TYPE 2-BACKWALL SUPPORTED APPROACH SLABS, OMIT WATERSTOP AND " CLOSED CELL NEOPRENE SPONGE ABOVE WATERSTOP. " CLOSED CELL 8"* NEOPRENE SPONGE COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY * MEASURED NORMAL TO ABUTMENT STANDARD NOTES TYPE 2 APPROACH SLAB (WITH OVERLAY)- DETAIL 5 1. FOR NOTES, SEE SHEETS 1 AND 2. BRIDGE APPROACH SLABS 2. USE ONLY APPROVED SEALS, AS LISTED IN BULLETIN 15. APPROACH SLAB SUPPORTED ON ABUTMENT BACKWALL WITH TOOTH EXPANSION DAM INSTALL JOINT SEALS TO A UNIFORM DEPTH WITH THE TOP OF THE SEAL FROM 1/2" TO 3/4" BELOW THE LEVEL OF THE PAVEMENT SURFACE. MAKE THE TOP EDGES OF THE TYPE 1 AND TYPE 2 - DETAIL 5 (TOOTH EXPANSION DAM WITH BACKWALL) CONTACT SURFACES ON BOTH SIDES OF THE SEAL AT THE SAME ELEVATION. 3. FOR FORMING AND WATERSTOP DETAILS, SEE SHEET 3. RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 11 OF 35 BD-628M 9"* SEE DETAIL H, SHEET 10 WATERSTOP 5" MIN. DECK 1’-4" SLAB PLUS HAUNCH 1 BEAM NOTCH 1 (REFER TO BD-661M) BOND BREAKER, 8"* " CLOSED CELL 2-PLY BIT. PAPER BRIDGE APPROACH SLAB NEOPRENE SPONGE CLASS AA CEMENT CONCRETE END OF BEAM VOID 1’-3"* C L BRGS. P/S CONCRETE ADJACENT BOX BEAM FRONT FACE 9"* 9"* MIN. MIN. OF ABUTMENT BATTER AS REQUIRED 1’-6"* MIN. * MEASURED NORMAL TO ABUTMENT TYPE 1 APPROACH SLAB (WITHOUT OVERLAY) - DETAIL 6 APPROACH SLAB SUPPORTED ON P/S CONCRETE ADJACENT BOX BEAMS FOR BEAM DEPTHS 27" AND GREATER NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. BURN OFF, TO TOP OF BEAM, REINFORCEMENT AND/OR LIFTING DEVICES PROTRUDING INTO APPROACH SLAB. 3. DETAILS SHOWN MAY ONLY BE USED IF THE BEAM DEPTH 9"* IS EQUAL TO OR EXCEEDS THE DEPTHS INDICATED. IF SUPERPAVE ASPHALT SEE DETAIL J, SHEET 11 OVERLAY (ROADWAY ITEM) WATERSTOP REQUIRED BEAM DEPTH IS LESS THAN INDICATED REFER TO DETAIL 10. 4. FOR FORMING AND WATERSTOP DETAILS, SEE SHEET 3. 1’-4" BEAM NOTCH 1 (REFER TO 1’-9" 5" 5" MIN. DECK SLAB PLUS HAUNCH 1 BD-661M) BOND BREAKER, VOID 8"* " CLOSED CELL 2-PLY BIT. PAPER NEOPRENE SPONGE END OF BEAM BRIDGE APPROACH SLAB CLASS AA CEMENT CONCRETE 1’-3"* C L BRGS. COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION P/S CONCRETE BUREAU OF PROJECT DELIVERY ADJACENT BOX BEAM FRONT FACE 9"* 9"* MIN. MIN. BATTER AS REQUIRED OF ABUTMENT STANDARD 1’-6"* MIN. * MEASURED NORMAL TO ABUTMENT BRIDGE APPROACH SLABS TYPE 2 APPROACH SLAB (WITH OVERLAY)- DETAIL 6 APPROACH SLAB SUPPORTED ON P/S CONCRETE TYPE 1 AND TYPE 2 - DETAIL 6 (P/S CONCRETE ADJACENT BOX BEAMS WITHOUT BACKWALL) ADJACENT BOX BEAMS FOR BEAM DEPTHS 30" AND GREATER RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 12 OF 35 BD-628M 9"* SEE DETAIL H, 8" MIN. SHEET 10 WATERSTOP 9 " M I N . " MIN. HAUNCH BEAM NOTCH (WITHOUT (REFER TO CAMBER) BD-661M) 1’-4" DECK SLAB 1 1 BOND BREAKER, 8"* " CLOSED CELL 2-PLY BIT. PAPER BRIDGE APPROACH SLAB NEOPRENE SPONGE CLASS AA CEMENT CONCRETE END OF BEAM 1’-0"* VOID 1’-3"* MIN. FULL DEPTH DIAPHRAGM (REFER TO BD-656M) C L BRGS. P/S CONCRETE SPREAD BOX BEAM FRONT FACE 9"* 9"* MIN. MIN. BATTER AS REQUIRED OF ABUTMENT 1’-6"* MIN. * MEASURED NORMAL TO ABUTMENT TYPE 1 APPROACH SLAB (WITHOUT OVERLAY) - DETAIL 7 APPROACH SLAB SUPPORTED ON P/S CONCRETE SPREAD BOX BEAMS AND FULL DEPTH CONCRETE END DIAPHRAGMS FOR BEAM DEPTHS 24" AND GREATER NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. BURN OFF, TO TOP OF BEAM, REINFORCEMENT AND/OR LIFTING DEVICES PROTRUDING INTO APPROACH SLAB. 3. DETAILS SHOWN MAY ONLY BE USED IF THE BEAM DEPTH IS EQUAL TO OR EXCEEDS THE DEPTHS INDICATED. IF 9"* SUPERPAVE ASPHALT SEE DETAIL J, 8" MIN. SHEET 11 OVERLAY (ROADWAY ITEM) WATERSTOP TO DETAIL 11. 4. FOR FORMING AND WATERSTOP DETAILS, SEE SHEET 3. " MIN. CAMBER) 9 " M I N . HAUNCH (WITHOUT BEAM NOTCH (REFER TO BD-661M) 1’-9" 1’-4" 5" DECK SLAB REQUIRED BEAM DEPTH IS LESS THAN INDICATED REFER 1 1 BOND BREAKER, " CLOSED CELL 8"* 2-PLY BIT. PAPER NEOPRENE SPONGE END OF BEAM BRIDGE APPROACH SLAB CLASS AA CEMENT CONCRETE 1’-0"* VOID 1’-3"* MIN. FULL DEPTH DIAPHRAGM C L BRGS. (REFER TO BD-656M) COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY P/S CONCRETE SPREAD BOX BEAM FRONT FACE 9"* 9"* MIN. MIN. STANDARD BRIDGE APPROACH SLABS BATTER AS REQUIRED OF ABUTMENT 1’-6"* MIN. * MEASURED NORMAL TO ABUTMENT TYPE 1 AND TYPE 2 - DETAIL 7 (P/S CONCRETE SPREAD BOX BEAMS WITHOUT BACKWALL) TYPE 2 APPROACH SLAB (WITH OVERLAY)- DETAIL 7 APPROACH SLAB SUPPORTED ON P/S CONCRETE SPREAD BOX BEAMS AND FULL DEPTH CONCRETE END DIAPHRAGMS RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHEET 13 OF 35 FOR BEAM DEPTHS 30" AND GREATER CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-628M 9"* SEE DETAIL H, 8" MIN. SHEET 10 WATERSTOP " MIN. 9 " M I N . 1 1 HAUNCH 1’-4" DECK SLAB (WITHOUT CAMBER) BOND BREAKER, 2-PLY BIT. PAPER BRIDGE APPROACH SLAB BEAM NOTCH 2" (REFER TO " CLOSED CELL BD-662M) 8"* CLASS AA CEMENT CONCRETE MIN. NEOPRENE SPONGE 1’-6"* MIN. FULL DEPTH DIAPHRAGM P/S CONCRETE (REFER TO BD-656M) I-BEAM END OF BEAM 4"* MIN. * MEASURED NORMAL TO ABUTMENT TYPE 1 APPROACH SLAB (WITHOUT OVERLAY) - DETAIL 8 APPROACH SLAB SUPPORTED ON P/S CONCRETE I-BEAMS AND FULL DEPTH CONCRETE END DIAPHRAGMS NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. BURN OFF, TO TOP OF BEAM, REINFORCEMENT AND/OR LIFTING DEVICES PROTRUDING INTO APPROACH SLAB. 3. FOR FORMING AND WATERSTOP DETAILS, SEE SHEET 3. 9"* SUPERPAVE ASPHALT SEE DETAIL J, 8" MIN. SHEET 11 OVERLAY (ROADWAY ITEM) WATERSTOP 1 1 9 " M I N . HAUNCH (WITHOUT CAMBER) 1’-9" " MIN. 1’-4" 5" DECK SLAB BEAM NOTCH BOND BREAKER, (REFER TO 2-PLY BIT. PAPER BD-662M) 2" " CLOSED CELL 8"* BRIDGE APPROACH SLAB CLASS AA CEMENT CONCRETE MIN. NEOPRENE SPONGE 1’-6"* MIN. FULL DEPTH P/S CONCRETE DIAPHRAGM I-BEAM (REFER TO BD-656M) COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY END OF BEAM STANDARD 4"* MIN. BRIDGE APPROACH SLABS * MEASURED NORMAL TO ABUTMENT TYPE 1 AND TYPE 2 - DETAIL 8 (P/S CONCRETE I-BEAMS WITHOUT BACKWALL) TYPE 2 APPROACH SLAB (WITH OVERLAY)- DETAIL 8 APPROACH SLAB SUPPORTED ON P/S CONCRETE I-BEAMS AND FULL DEPTH CONCRETE END DIAPHRAGMS RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 14 OF 35 BD-628M 9"* SEE DETAIL H, 8" MIN. SHEET 10 WATERSTOP DECK SLAB 1’-4" 12"* MIN. " MIN. HAUNCH BEAM NOTCH 3"* (WITHOUT (REFER TO MIN. CAMBER) BD-611M) BOND BREAKER, 2-PLY BIT. PAPER ROUGH CONSTR. JOINT 3" BRIDGE APPROACH SLAB MIN. CLASS AA CEMENT CONCRETE 8"* " CLOSED CELL NEOPRENE SPONGE FULL DEPTH DIAPHRAGM (REFER TO BD-611M) STEEL END OF BEAM I-BEAM 4"* MIN. * MEASURED NORMAL TO ABUTMENT TYPE 1 APPROACH SLAB (WITHOUT OVERLAY) - DETAIL 9 APPROACH SLAB SUPPORTED ON STEEL I-BEAMS AND FULL DEPTH CONCRETE END DIAPHRAGMS FOR BEAM DEPTHS 2’-1" AND GREATER NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. DETAILS SHOWN MAY ONLY BE USED IF THE BEAM DEPTH IS EQUAL TO OR EXCEEDS THE DEPTHS INDICATED. IF REQUIRED BEAM DEPTH IS LESS THAN INDICATED REFER TO DETAIL 12. 3. FOR FORMING AND WATERSTOP DETAILS, SEE SHEET 3. 9"* SUPERPAVE ASPHALT SEE DETAIL J, 8" MIN. SHEET 11 OVERLAY (ROADWAY ITEM) WATERSTOP 12"* HAUNCH MIN. (WITHOUT BEAM NOTCH CAMBER) (REFER TO 3"* BD-611M) MIN. 1’-9" " MIN. 1’-4" 5" DECK SLAB BOND BREAKER, ROUGH CONSTR. JOINT 2-PLY BIT. PAPER 3" " CLOSED CELL BRIDGE APPROACH SLAB CLASS AA CEMENT CONCRETE MIN. 8"* NEOPRENE SPONGE FULL DEPTH DIAPHRAGM (REFER TO BD-611M) STEEL END OF BEAM COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY I-BEAM STANDARD 4"* MIN. BRIDGE APPROACH SLABS * MEASURED NORMAL TO ABUTMENT TYPE 1 AND TYPE 2 - DETAIL 9 (STEEL BEAMS WITHOUT BACKWALL) TYPE 2 APPROACH SLAB (WITH OVERLAY)- DETAIL 9 APPROACH SLAB SUPPORTED ON STEEL I-BEAMS AND FULL DEPTH CONCRETE END DIAPHRAGMS RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHEET 15 OF 35 FOR BEAM DEPTHS 2’-6" AND GREATER CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-628M 9"* SEE DETAIL H, #6 @ 9" SHEET 10 WATERSTOP EXTEND 2’-9" CL BRGS. BEYOND 5" MIN. DECK SLAB PLUS HAUNCH 1’-4" 3" CLR. " CLOSED CELL (TYP.) NEOPRENE SPONGE 1 BEAM NOTCH 1’-3"* 1’-4"* 7"* 1 9" (REFER TO BD-661M) BOND BREAKER, 2-PLY BIT. PAPER DOWEL HOLE BRIDGE APPROACH SLAB 0" 3" CLR. PROVIDE #5 BARS (TYP.) CLASS AA CEMENT CONCRETE AS INDICATED, C L BRGS. #5 @ 9" 1’-0" MAX. 0" P/S CONCRETE #6 PLACED ADJACENT BOX BEAM 0" 3" CLR. #6 @ 6" (TYP.) MIN. 9" VERTICAL SPACING MIN. END OF BEAM 1’-0" VOID INSIDE HOOK 3" CLOSED CELL #5 BARS AT NEOPRENE SPONGE " PREFORMED 1’-0" MAX. C/C 9"* 9"* POLYSTYRENE 1’-4"* MIN. MIN. (TYP.) REINFORCEMENT PER BD-621M 1 ’ M 6 I " N . 1’-6" CELLULAR FRONT FACE OF ABUTMENT MIN. ABUTMENT 1’-6"* MIN. * MEASURED NORMAL VERTICAL 1 TO ABUTMENT REAR FACE 1 ABUTMENT CORBEL ABUTMENT (REFER REINFORCEMENT DETAIL TO BD-621M FOR ADDITIONAL DETAILS) (BATTERED REAR FACE) TYPE 1 APPROACH SLAB (WITHOUT OVERLAY) - DETAIL 10 APPROACH SLAB SUPPORTED ON ABUTMENT ADJACENT TO P/S CONCRETE ADJACENT BOX BEAMS FOR BEAM DEPTHS LESS THAN 27" NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. FOR FORMING AND WATERSTOP DETAILS, SEE SHEET 3. 9"* #6 @ 9" SEE DETAIL J, EXTEND 2’-9" SHEET 11 SUPERPAVE ASPHALT WATERSTOP CL BRGS. BEYOND OVERLAY (ROADWAY ITEM) " CLOSED CELL NEOPRENE SPONGE 5" 5" MIN. DECK SLAB PLUS HAUNCH 1 1’-3"* 7"* 1’-4" (TYP.) BEAM NOTCH BOND BREAKER, 1 (REFER TO 2-PLY BIT. PAPER 1’-9" 3" CLR. BD-661M) VOID END OF BEAM 3" CLR. DOWEL HOLE 0" PROVIDE #5 BARS (TYP.) C L BRGS. #5 @ 9" AS INDICATED, BRIDGE APPROACH SLAB 1’-0" MAX. CLASS AA CEMENT CONCRETE #6 PLACED ADJACENT BOX BEAM INSIDE HOOK 9" VERTICAL SPACING P/S CONCRETE 3" CLOSED CELL NEOPRENE SPONGE 9"* MIN. MIN. POLYSTYRENE 1’-4"* MIN. CELLULAR 9"* OF ABUTMENT 1’-6" " PREFORMED FRONT FACE COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY 1’-6"* MIN. STANDARD * MEASURED NORMAL VERTICAL 1 TO ABUTMENT BRIDGE APPROACH SLABS REAR FACE 1 ABUTMENT (REFER TYPE 1 AND TYPE 2 - DETAIL 10 TO BD-621M FOR ADDITIONAL DETAILS) (P/S CONCRETE ADJACENT BOX BEAMS WITH ABUTMENT CORBEL) TYPE 2 APPROACH SLAB (WITH OVERLAY)- DETAIL 10 APPROACH SLAB SUPPORTED ON ABUTMENT ADJACENT TO P/S CONCRETE RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHEET 16 OF 35 ADJACENT BOX BEAMS FOR BEAM DEPTHS LESS THAN 30" CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-628M 9"* SEE DETAIL H, #6 @ 9" 8" MIN. SHEET 10 WATERSTOP EXTEND 2’-9" DECK SLAB CL BRGS. BEYOND 1’-4" 3" CLR. " CLOSED CELL (TYP.) 6 " M I N . NEOPRENE SPONGE " MIN. HAUNCH BEAM NOTCH (WITHOUT (REFER TO CAMBER) BD-661M) 1’-0"* 7"* END OF BEAM 1 BOND BREAKER, 1 VOID 3" CLR. 2-PLY BIT. PAPER 0" BRIDGE APPROACH SLAB (TYP.) CLASS AA CEMENT CONCRETE PROVIDE #5 BARS C L BRGS. AS INDICATED, #5 @ 9" 1’-0" MAX. AT BEAMS #5 @ 9" VERTICAL SPACING P/S CONCRETE 9" BETWEEN SPREAD BOX BEAM #6 PLACED BEAMS INSIDE HOOK 3" CLOSED CELL NEOPRENE SPONGE (REFER TO BD-656M) MIN. 1’-6" CELLULAR 1’-3"* POLYSTYRENE MIN. " PREFORMED FULL DEPTH DIAPHRAGM FRONT FACE 9"* 9"* MIN. MIN. 1’-4"* OF ABUTMENT 1’-6"* VERTICAL MIN. * MEASURED NORMAL 1 TO ABUTMENT REAR FACE 1 ABUTMENT (REFER TO BD-621M FOR ADDITIONAL DETAILS) TYPE 1 APPROACH SLAB (WITHOUT OVERLAY) - DETAIL 11 APPROACH SLAB SUPPORTED ON ABUTMENT ADJACENT TO P/S CONCRETE SPREAD BOX BEAMS AND FULL DEPTH CONCRETE END DIAPHRAGMS FOR BEAM DEPTHS LESS THAN 24" NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. 9"* 2. FOR FORMING AND WATERSTOP DETAILS, SEE SHEET 3. 3. FOR ABUTMENT CORBEL REINFORCEMENT DETAIL, SEE SHEET 16. 8" MIN. DECK SLAB #6 @ 9" SEE DETAIL J, EXTEND 2’-9" SHEET 11 SUPERPAVE ASPHALT WATERSTOP CL BRGS. BEYOND OVERLAY (ROADWAY ITEM) " CLOSED CELL 5" NEOPRENE SPONGE BEAM NOTCH (WITHOUT (REFER TO 7"* BOND BREAKER, 2-PLY BIT. PAPER BD-661M) END OF BEAM 1 1 VOID 3" CLR. (TYP.) 0" PROVIDE #5 BARS C L BRGS. #5 @ 9" AT BEAMS #5 @ 9" AS INDICATED, BRIDGE APPROACH SLAB 1’-0" MAX. CLASS AA CEMENT CONCRETE VERTICAL SPACING #6 PLACED BEAMS INSIDE HOOK 9" BETWEEN 3" CLOSED CELL NEOPRENE SPONGE CELLULAR 1’-3"* (REFER TO BD-656M) MIN. POLYSTYRENE MIN. " PREFORMED FULL DEPTH DIAPHRAGM 1’-6" CAMBER) 1’-0"* 1’-4" 6 " M I N . (TYP.) HAUNCH 1’-9" 3" CLR. " MIN. FRONT FACE 9"* 9"* MIN. MIN. COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION 1’-4"* BUREAU OF PROJECT DELIVERY OF ABUTMENT 1’-6"* * MEASURED NORMAL TO ABUTMENT VERTICAL MIN. 1 STANDARD REAR FACE 1 ABUTMENT (REFER TO BD-621M FOR ADDITIONAL DETAILS) TYPE 2 APPROACH SLAB (WITH OVERLAY)- DETAIL 11 BRIDGE APPROACH SLABS TYPE 1 AND TYPE 2 - DETAIL 11 (P/S CONCRETE SPREAD BOX BEAMS WITH ABUTMENT CORBEL) APPROACH SLAB SUPPORTED ON ABUTMENT ADJACENT TO P/S CONCRETE RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHEET 17 OF 35 SPREAD BOX BEAMS AND FULL DEPTH CONCRETE END DIAPHRAGMS FOR BEAM DEPTHS LESS THAN 30" CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-628M 9"* SEE DETAIL H, #6 @ 9" 8" MIN. SHEET 10 WATERSTOP EXTEND 2’-9" DECK SLAB CL BRGS. BEYOND 1’-4" 1’-4" " MIN. 1’-9"* " CLOSED CELL MIN. NEOPRENE SPONGE 4" ROUGH CONSTR. HAUNCH JOINT 3" CLR. (WITHOUT (TYP.) CAMBER) BOND BREAKER, WORK POINT 2-PLY BIT. PAPER BRIDGE APPROACH SLAB END OF BEAM 4"* #5 @ 9" 7"* MIN. BETWEEN CLASS AA CEMENT CONCRETE PROVIDE #5 BARS AS INDICATED, 1’-0" MAX. BEAMS VERTICAL SPACING STEEL 9" C L BRGS. I-BEAM #6 PLACED INSIDE HOOK 3" CLOSED CELL NEOPRENE SPONGE POLYSTYRENE 3" CLR. 10"* MIN. (POT BEARINGS) (TYP.) OR 1’-3"* MIN. MIN. CELLULAR (REFER TO BD-611M) 1’-6" " PREFORMED FULL DEPTH DIAPHRAGM FRONT FACE (ELASTOMERIC BEARINGS) 9"* 9"* MIN. MIN. 1’-4"* OF ABUTMENT 1’-6"* * MEASURED NORMAL VERTICAL MIN. TO ABUTMENT 1 REAR FACE 1 ABUTMENT (REFER TO BD-621M FOR ADDITIONAL DETAILS) TYPE 1 APPROACH SLAB (WITHOUT OVERLAY) - DETAIL 12 APPROACH SLAB SUPPORTED ON ABUTMENT ADJACENT TO STEEL I-BEAMS AND FULL DEPTH CONCRETE END DIAPHRAGMS FOR BEAM DEPTHS LESS THAN 2’-1" NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. FOR FORMING AND WATERSTOP DETAILS, SEE SHEET 3. 9"* 3. FOR ABUTMENT CORBEL REINFORCEMENT DETAIL, SEE SHEET 16. 8" MIN. DECK SLAB #6 @ 9" SEE DETAIL J, EXTEND 2’-9" SHEET 11 SUPERPAVE ASPHALT WATERSTOP CL BRGS. BEYOND OVERLAY (ROADWAY ITEM) " CLOSED CELL 5" NEOPRENE SPONGE MIN. 3" CLR. (TYP.) HAUNCH BOND BREAKER, 2-PLY BIT. PAPER (WITHOUT CAMBER) 4"* 1’-4" " MIN. 1’-9" 1’-4" 1’-9"* 7"* ROUGH CONSTR. JOINT MIN. END OF BEAM #5 @ 9" PROVIDE #5 BARS BETWEEN AS INDICATED, BEAMS 1’-0" MAX. BRIDGE APPROACH SLAB CLASS AA CEMENT CONCRETE VERTICAL SPACING STEEL #6 PLACED INSIDE HOOK 3" CLOSED CELL 9" I-BEAM C L BRGS. NEOPRENE SPONGE COMMONWEALTH OF PENNSYLVANIA 10"* MIN. (POT BEARINGS) 3" CLR. OR 1’-3"* MIN. (TYP.) POLYSTYRENE MIN. CELLULAR (REFER TO BD-611M) 1’-6" " PREFORMED FULL DEPTH DIAPHRAGM DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY FRONT FACE (ELASTOMERIC BEARINGS) 9"* 9"* MIN. MIN. 1’-4"* OF ABUTMENT * MEASURED NORMAL TO ABUTMENT 1’-6"* STANDARD VERTICAL MIN. 1 REAR FACE 1 BRIDGE APPROACH SLABS ABUTMENT (REFER TO BD-621M FOR ADDITIONAL DETAILS) TYPE 1 AND TYPE 2 - DETAIL 12 (STEEL BEAMS WITH ABUTMENT CORBEL) TYPE 2 APPROACH SLAB (WITH OVERLAY)- DETAIL 12 APPROACH SLAB SUPPORTED ON ABUTMENT ADJACENT TO RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHEET 18 OF 35 STEEL I-BEAMS AND FULL DEPTH CONCRETE END DIAPHRAGMS FOR BEAM DEPTHS LESS THAN 2’-6" CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-628M 1" FLUSH 7’-6" ADJACENT TO CONCRETE PAVEMENT EXPANSION JOINT 8’-6" ADJACENT TO PAVEMENT RELIEF JOINT OUTSIDE FACE OF BARRIER E BARRIER 5’-0" ADJACENT TO FLEXIBLE PAVEMENT CURB 5’-6" (ROADWAY MIN. ITEM) DESCRIPTION OF PLANS FOR DESCRIPTION OF DETAILS FOR TYPE 3 APPROACH SLABS TYPE 3 APPROACH SLAB PLAN DESCRIPTION SHEET NO. DETAIL APPROACH SLAB WITH 1 INLET 19 SHOULDER ITEM) 0" ’10 N. 3) MI TE NO EE (S SHEET NO. 13 LONG U-WINGS (ROADWAY DESCRIPTION END OF APPROACH SLAB WITH NEOPRENE STRIP SEAL DAM 22 ADJACENT TO FLEXIBLE PAVEMENT END OF APPROACH SLAB WITH NEOPRENE STRIP SEAL DAM APPROACH SLAB WITH 14 22 ADJACENT TO CONCRETE PAVEMENT FLARED WINGS OR 2 20 SHORT U-WINGS WITH END OF APPROACH SLAB WITH NEOPRENE STRIP SEAL DAM MOMENT SLABS 15 22 ADJACENT TO PAVEMENT RELIEF JOINT APPROACH SLAB WITH APPROACH SLAB CONNECTED TO P/S CONCRETE ADJACENT 3 FLARED WINGS OR 21 19 24 BOX BEAMS WITH BACKWALL SHORT U-WINGS OPTIONAL KEYED #5 @ 12" AB SL APPROACH SLAB CONNECTED TO THE SUPERSTRUCTURE R PE EE SL 9" @ T. #5 BO & P TO J J 21 (P/S CONCRETE I-BEAMS AND CONCRETE END 25 BRIDGE WIDTH DIAPHRAGMS) WITH BACKWALL APPROACH SLAB CONNECTED TO THE SUPERSTRUCTURE 22 (STEEL I-BEAMS AND CONCRETE END DIAPHRAGMS) 25 WITH BACKWALL APPROACH WINGWALL SLAB WITH WITH BARRIER BARRIER JOINT OPENING LL WA CK BA " -0 3’ P TO " T. 12 BO @ " 12 #5 @ #7 5" AS REQUIRED FOR NEOPRENE STRIP SEAL " -0 2’ T OU CK O BL TOP OF BARRIER " PLATE OPTIONAL KEYED EXTEND JOINT SEAL UP BARRIER SHOULDER 9" NG VI PA H TC NO M AG R H AP DI ROADWAY WIDTH SIDE 5" CURB TO CURB WIDTH HIGHWAY 30’-0" APPROACH SLAB #5 @ 12" TOP C L #10 @ 6" BOT. SKEW ANGLE TO MATCH BRIDGE SKEW SIDE 24 APPROACH SLAB CONNECTED TO THE SUPERSTRUCTURE APPROACH SLAB BRIDGE (P/S CONCRETE SPREAD BOX BEAMS AND CONCRETE END DIAPHRAGMS) WITH BACKWALL SLEEPER SLAB #5 @ 12" 20 #8 @ 12" TOP & BOT. CONSTRUCTION JOINT (SEE DETAIL B, SHEET 5) CONSTRUCTION JOINT FACE IN ACCORDANCE WITH (SEE DETAIL B, SHEET 5) BC-766M. EXTEND WATERSTOP TO CONSTRUCTION JOINT OUTSIDE FACE OF BARRIER, SEE SEE DETAIL K, GUTTER LINE V-NOTCH SHEET 20 BOTTOM OF APPROACH SLAB TOP OF WINGWALL TERMINATION DETAIL ON SHEET 4. AND CONSTR JOINT 1/2" OPEN JOINT IN BARRIER, SEE BC-752M FOR DETAILS (TYP). 5’-6" E OF SAW CUT FOR JOINT SEAL K OUTSIDE FACE K MIN. OF BARRIER JOINT OPENING AS REQUIRED FOR BARRIER 1" PREFORMED OMIT CAULKING COMPOUND IN AREA BEND LINE CELLULAR POLYSTYRENE WINGWALL NEOPRENE STRIP SEAL PLAN 1 (TYP. EACH SIDE) TYPE 3 SLEEPER SLAB " BETWEEN (FAR SIDE OF BOTTOM OF PLATE WINGWALL) AND TOP OF WALL APPROACH SLAB WITH LONG U-WINGS SECTION K-K NOTES 30’-0" SEE DETAILS 2’-9" LIMITS OF (TYP.) CONSTRUCTION JOINT BLOCKOUT " CLR. BRIDGE TRANSVERSE SIDE #5 @ 12" 19 THRU 22 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. FOR SECTION E-E, SEE SHEET 8. HIGHWAY 3. INLET TO BE LOCATED SUCH THAT ITS OUTFLOW PIPE MISSES SIDE NEOPRENE STRIP SEAL CONCRETE DAM (SEE BC-767M) APPROACH SLAB TYPE 2-SC POSTS IN GUIDE RAIL TRANSITION. SEE DETAILS 13, 14 AND 15 2 1’-6" 3" CLR. #5 @ 12" #7 @ 12" #10 @ 6" (BOTH ENDS) 3" CLR. (TYP.) ITEM) POLYETHYLENE SHEETING UNDERNEATH APPROACH SLAB PAY LIMITS FOR BRIDGE APPROACH SLAB QUANTITIES DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY (ROADWAY ITEM)(REFER (ROADWAY PROVIDE 2 LAYERS OF 4 MIL. #6 @ 9" DIAPHRAGM COMMONWEALTH OF PENNSYLVANIA SUBSURFACE DRAIN SUBBASE TO INSTRUCTIONS SLEEPER SLAB TO DESIGNER NOTES) PAY LIMIT: CONCRETE STANDARD PAVEMENT, FLEXIBLE PAVEMENT OR PAVEMENT BACKWALL BRIDGE APPROACH SLABS RELIEF JOINT (ROADWAY ITEMS) PLACED PARALLEL TO BEAMS AND TYPE 3 - PLAN 1 AND SECTION SPACED BETWEEN BEAMS, BEAM WEBS OR PLACED WITH P/S ADJACENT BOX BEAMS SECTION J-J RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 19 OF 35 BD-628M EXPANSION JOINT 10’-0" MIN. OUTSIDE FACE CURB EXPANSION JOINT OF BARRIER E (ROADWAY ITEM) (SEE NOTE 6) M (SEE NOTE 4) BARRIER 1" FLUSH MOMENT SLAB WITH BARRIER ROADWAY PAVEMENT MOMENT SLAB WITH BARRIER SHOULDER/ 8’-0" MIN. (ROADWAY ITEM) SHOULDER INLET 10’-0" MIN. (SEE NOTE 7) 8’-0" MIN. LANE LINE OUTSIDE FACE OF BARRIER TIE BARS OR TIE BOLTS 6" MIN. M OPTIONAL KEYED #5 @ 12" CONSTRUCTION JOINT AB SL R PE EE SL 9" @ T. #5 BO & P TO 5" J J #5 @ #7 5" " -0 2’ T OU CK O BL (SEE DETAIL B, SHEET 5) OUTSIDE FACE OF BARRIER, SEE SECTION M-M M OPTIONAL KEYED BC-766M. EXTEND WATERSTOP TO MOMENT SLAB ADJACENT TO TYPE 3 OR TYPE 4 APPROACH SLAB " -0 3’ P TO " T. 12 BO " 12 CONSTRUCTION JOINT FACE IN ACCORDANCE WITH SHOULDER JOINT CONSTRUCTION JOINT TERMINATION DETAIL ON SHEET 4. SHOULDER EXTEND JOINT SEAL UP BARRIER @ 8’-0" MIN. LL WA CK BA 9" NG VI PA H TC NO M AG R H AP DI BRIDGE WIDTH SIDE APPROACH SLAB CURB TO CURB WIDTH HIGHWAY 30’-0" SIDE ROADWAY WIDTH C L #5 @ 12" TOP MATCH BRIDGE SKEW #10 @ 6" BOT. SKEW ANGLE TO BRIDGE LONGITUDINAL (REFER TO RC-20M) SLEEPER SLAB APPROACH SLAB SUBBASE (ROADWAY ITEM) #8 @ 12" TOP & BOT. (SEE DETAIL B, SHEET 5) #5 @ 12" NOTES 1/2" OPEN JOINT IN BARRIER, 1. FOR NOTES, SEE SHEETS 1 AND 2. SEE BC-752M FOR DETAILS (TYP). OUTSIDE FACE E OF SAW CUT FOR JOINT SEAL M OF BARRIER L L EXPANSION JOINT JOINT OPENING AS REQUIRED (SEE NOTE 4) FOR NEOPRENE STRIP SEAL BARRIER 2. FOR SECTION E-E, SEE SHEET 8. OMIT CAULKING COMPOUND IN AREA 3. FOR SECTION J-J, SEE SHEET 19. 4. PROVIDE THE FOLLOWING JOINT OPENINGS: APPROACH SLAB ADJACENT TO CONCRETE OR FLEXIBLE PAVEMENT: 1" FLUSH EXPANSION JOINT 10’-0" MIN. (TYP. EACH SIDE) APPROACH SLAB ADJACENT TO PAVEMENT RELIEF JOINT: MOMENT SLAB WITH BARRIER 1’-0" AND PROVIDE SLIDING PLATE IN ACCORDANCE WITH THE DETAILS SHOWN ON BD-627M. PLAN 2 5. FOR ADDITIONAL MOMENT SLAB DETAILS REFER TO BD-627M. 5’-0" ADJACENT TO FLEXIBLE PAVEMENT TYPE 3 7’-6" ADJACENT TO CONCRETE PAVEMENT APPROACH SLAB WITH FLARED WINGS OR 8’-6" ADJACENT TO PAVEMENT RELIEF JOINT SHORT U-WINGS WITH MOMENT SLABS 6. PROVIDE TYPE 2-SC GUIDE RAIL WITH POSTS AT 3’-1" SPA. ALONG CURB AFTER APPROACH END TRANSITION. 7. INLET TO BE LOCATED SUCH THAT ITS OUTFLOW PIPE MISSES TYPE 2-SC POSTS IN GUIDE RAIL TRANSITION. JOINT OPENING AS REQUIRED APPROACH MOMENT SLAB SLAB WITH WITH BARRIER FOR NEOPRENE STRIP SEAL BARRIER APPROACH ROADWAY SLAB SIDE SIDE EXPANSION JOINT 3" 1" (SEE NOTE 4) JOINT OPENING AS REQUIRED FOR NEOPRENE STRIP SEAL 3-" DIA. GALVANIZED " A325 BOLTS WITH GALVANIZED WASHERS WITH THREADED " PLATE 6 " REMOVABLE COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY GALVANIZED 6 BEND LINE SEE DETAIL K INSERTS (TYP) " 1’-7" TOP OF BARRIER STEEL PLATE GUTTER LINE V-NOTCH 3" " DIA. HOLES BOTTOM OF 4" 4" MIN. MIN. APPROACH SLAB BOTTOM OF STANDARD NOTE: BRIDGE APPROACH SLABS DESIGNER TO DETERMINE LENGTH (L) MOMENT SLAB L OF PLATE. PLATE AND OTHER ITEMS TYPE 3 - PLAN 2 INCIDENTAL TO COST OF NEOPRENE STRIP SEAL DAM. " BETWEEN BOTTOM OF PLATE AND TOP OF SLEEPER SLAB DETAIL K SLEEPER SLAB END COVER PLATE SECTION L-L RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 20 OF 35 BD-628M EDGE OF " SLAB (TYP.) SLIDING CURB (ROADWAY ITEM) PLATE (SEE NOTE 5) Z SEE DETAIL C, FOR NEOPRENE STRIP SEAL APPROACH ROADWAY SLAB SIDE SIDE INLET (ROADWAY 0" ’10 N. 6) MI TE NO EE S ( 4-" DIA. GALVANIZED WASHERS WITH THREADED 2’-1" #5 @ 12" J LL WA CK BA @ #5 @ #7 5" OPTIONAL KEYED (SEE DETAIL B, SHEET 5) BC-766M. EXTEND WATERSTOP TO 3" 4" 4" MIN. MIN. NOTE: DESIGNER TO DETERMINE LENGTH (L) OF PLATE. PLATE AND OTHER ITEMS L INCIDENTAL TO COST OF NEOPRENE STRIP SEAL DAM. DETAIL R END COVER PLATE " -0 2’ UT KO OC L B CONSTRUCTION JOINT FACE IN ACCORDANCE WITH " DIA. HOLES " -0 3’ P TO " T. 12 BO " 12 SHOULDER EXTEND JOINT SEAL UP BARRIER GALVANIZED " J BRIDGE WIDTH SIDE 5" CONSTRUCTION JOINT CURB TO CURB WIDTH 30’-0" APPROACH SLAB ROADWAY WIDTH HIGHWAY #5 @ 12" TOP C L #10 @ 6" BOT. MATCH BRIDGE SKEW SLEEPER SLAB #8 @ 12" TOP & BOT. APPROACH SLAB SKEW ANGLE TO 9" NG VI PA H TC NO M AG R H AP DI " REMOVABLE 6 AB SL R PE EE SL 9" @ T. #5 BO & P TO (SEE DETAIL B, SHEET 5) #5 @ 12" SIDE INSERTS (TYP) STEEL PLATE CONSTRUCTION JOINT BRIDGE A325 BOLTS WITH GALVANIZED 6 ITEM) 1" 2 " Z SHEET 5 (TYP.) OPTIONAL KEYED JOINT OPENING AS REQUIRED SHOULDER 1’-4 C EXPANSION JOINT 8 " C E (TYP.) OF BARRIER " 1" FLUSH 8" OUTSIDE FACE CURB (AS REQUIRED) " #10 BOT. " #5 TOP APPROACH 6 BEND LINE BARRIER 10’-0" MIN. " " OUTSIDE FACE OF BARRIER, SEE SLIDING TERMINATION DETAIL ON SHEET 4. 8 PLATE NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. FOR SECTION C-C, SEE SHEET 5. 3. FOR SECTION E-E, SEE SHEET 8. 4. FOR SECTION J-J, SEE SHEET 19. 5. USE GUIDE RAIL TRANSITION SIMILAR TO DETAIL ON BC-739M. ONCE BEYOND INLET, PROVIDE GUIDE RAIL AND POSTS AS PER 1/2" OPEN JOINT IN BARRIER, RC-50M AND/OR RC-52M. OF SAW CUT FOR JOINT SEAL N OF BARRIER E 8" OUTSIDE FACE 1" FLUSH BARRIER OMIT CAULKING COMPOUND IN AREA CURB SEE BC-752M FOR DETAILS (TYP). N EXPANSION JOINT CURB (ROADWAY ITEM) #5 TOP 6. INLET TO BE LOCATED SUCH THAT ITS OUTFLOW PIPE MISSES TYPE 2-SC POSTS IN GUIDE RAIL TRANSITION. #10 BOT. (AS REQUIRED) 10’-0" MIN. JOINT OPENING AS REQUIRED FOR NEOPRENE STRIP SEAL BEND LINE (TYP. EACH SIDE) PLAN 3 5’-0" ADJACENT TO FLEXIBLE PAVEMENT 7’-6" ADJACENT TO CONCRETE PAVEMENT TYPE 3 8’-6" ADJACENT TO PAVEMENT RELIEF JOINT APPROACH SLAB WITH FLARED WINGS OR SHORT U-WINGS APPROACH SLAB CURB (ROADWAY ITEM) WITH BARRIER AND CURB COUNTERSUNK MACHINE SCREW WITH CONCRETE INSERT JOINT OPENING AS REQUIRED CAST IN PLACE (TYP.) FOR NEOPRENE STRIP SEAL 1" FLUSH TOP OF BARRIER 2" " SLIDING PLATE EXPANSION JOINT CLR. COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION " BUREAU OF PROJECT DELIVERY 8"x 8" CURB TOP OF CURB GUTTER LINE 1/2" GALVANIZED STEEL V-NOTCH PLATE, SEE DETAIL R STANDARD 45 " 5 " PLATE STEEL SEE DETAIL R EXTRUSION 6" 6" BRIDGE APPROACH SLABS 6" TYPE 3 - PLAN 3 " BETWEEN BOTTOM OF PLATE AND TOP OF SLEEPER SLAB SLEEPER SLAB SECTION N-N SECTION Z-Z RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 21 OF 35 BD-628M CONCRETE APPROACH SLAB CONCRETE APPROACH SLAB NEOPRENE STRIP SEAL CLASS AAAP CEMENT CONCRETE 1 ROUGH CLASS AAAP CONSTR CEMENT CONCRETE STRUCTURE ROADWAY SEE NOTE 2 3" CLR. PAVEMENT SLIDING SURFACE 1’-6" SEE NOTE 2 PAVEMENT TYPE E JOINT REFER TO RC-20M 9" SLIDING SURFACE DEPTH OF " CEMENT CONCRETE CLASS AAAP #5 @ 9" SIDE OF JT. (SEE BC-767M) 1 JOINT 1’-0" JOINT #5 @ 12" 2’-6" CONSTR (TYP.) #6 BARS EACH 1’-0" ROUGH CLR. 2’-6" 6" 9" 3" 1’-6" 3" CLR. 3" CLR. (TYP.) 1 1 #5 @ 9" 0" 2" 3" 1 CLASS AA 1 CLR. 0" #5 @ 9" SEE NOTE 4 1 2" 3" 1 CLR. 1 #8 @ 12" CEMENT CONCRETE #8 @ 12" 1" POLY-VINYL CHLORIDE 3" CLR. 3" CLR. PIPE (SCHEDULE 40) SPACED (TYP.) (TYP.) AT 10’-0" MAX. SPACING 1" POLY-VINYL CHLORIDE 6" MIN. 5’-0" (TYP.) SLEEPER SLAB PIPE (SCHEDULE 40) SPACED AT 10’-0" MAX. SPACING 6" MIN. 7’-6" (TYP.) SLEEPER SLAB TYPE 3 AND TYPE 5 APPROACH SLAB - DETAIL 13 CEMENT CONCRETE 1 SEE NOTE 4 CLASS AA CEMENT CONCRETE 1’-6" CLASS AAAP SHEET 9 2’-0" TOP & BOT. 1’-6" SEE DETAIL F, STRUCTURE #5 @ 9" SIDE OF JT. (SEE BC-767M) SEE NOTE 2 ROADWAY #5 @ 12" PAVEMENT " CLR. 2 (TYP.) DAM (SEE BC-767M) CONCRETE PAVEMENT (ROADWAY ITEM) 3’-0" 6" #6 BARS EACH SLIDING SURFACE 2’-0" (ROADWAY ITEM) 2’-0" 2’-6" 3’-0" TOP & BOT. CONSTRUCTION JOINT CONCRETE FLEXIBLE PAVEMENT CLR. 2’-0" LIMITS OF BLOCKOUT 2 CONSTRUCTION JOINT NEOPRENE STRIP SEAL TRANSVERSE DAM (SEE BC-767M) 3" LIMITS OF BLOCKOUT CLR. TRANSVERSE TYPE 3 AND TYPE 5 APPROACH SLAB - DETAIL 14 END OF APPROACH SLAB WITH NEOPRENE END OF APPROACH SLAB WITH NEOPRENE STRIP SEAL DAM ADJACENT TO FLEXIBLE PAVEMENT STRIP SEAL DAM ADJACENT TO CONCRETE PAVEMENT (SEE NOTE 3) NEOPRENE STRIP SEAL DAM (SEE BC-767M) CONCRETE APPROACH SLAB 2’-0" TRANSVERSE LIMITS OF BLOCKOUT CONSTRUCTION JOINT 2’-0" PAVEMENT RELIEF JOINT FOR DETAILS NOT SHOWN REFER TO RC-24M NOTES 3’-0" #5 @ 12" PAVEMENT #5 @ 9" SIDE OF JT. (ROADWAY ITEM) SLIDING SURFACE SEE NOTE 2 (SEE BC-767M) PAVEMENT CONCRETE DEPTH OF " 2 #6 BARS EACH REINFORCED CONCRETE 1. FOR NOTES, SEE SHEETS 1 AND 2. 6" (TYP.) CLR. TOP & BOT. 2’-6" 1’-0" 2’-0" 2. TROWEL SMOOTH AND PLACE 2 LAYERS OF 4 MIL. POLYETHYLENE SHEETING AS BOND BREAKER. 3. USE DETAIL 14 ONLY WHEN LIMITED MOVEMENT IS ANTICIPATED IN THE ROADWAY OTHERWISE USE DETAIL 15. REFER TO RC-24M FOR ROUGH CLR. CLASS AAAP CONSTR 1 1 CEMENT CONCRETE 1’-0" JOINT STRUCTURE (TYP.) 3" 4. TYPE 3 APPROACH SLAB; SUBBASE (ROADWAY ITEM) TYPE 5 APPROACH SLAB; STRUCTURAL BACKFILL, REFER TO RC-12M. 2’-6" ROADWAY SEE NOTE 2 PAVEMENT 3" SLIDING SURFACE 3" CLR. CLR. CEMENT CONCRETE 1’-6" CLASS AAAP ADDITIONAL INFORMATION. 1 0" #5 @ 9" 2" 1 3" 1 CLR. CLASS AA CEMENT CONCRETE 1 #8 @ 12" SEE NOTE 4 1" POLY-VINYL CHLORIDE COMMONWEALTH OF PENNSYLVANIA PIPE (SCHEDULE 40) SPACED AT 10’-0" MAX. SPACING 3" CLR. DEPARTMENT OF TRANSPORTATION (TYP.) 6" MIN. 8’-6" (TYP.) SLEEPER SLAB BUREAU OF PROJECT DELIVERY STANDARD TYPE 3 AND TYPE 5 APPROACH SLAB - DETAIL 15 BRIDGE APPROACH SLABS END OF APPROACH SLAB WITH NEOPRENE STRIP SEAL DAM ADJACENT TO PAVEMENT RELIEF JOINT TYPE 3 & TYPE 5 - DETAILS 13, 14 AND 15 (ADJACENT TO ROADWAY) RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 22 OF 35 BD-628M (TYP.) 5’-0" (TYP.) SLEEPER SLAB STRUCTURE ROADWAY PAVEMENT PAVEMENT 1’-6" 1’-0" 2’-6" 3" CLR. CEMENT 9" #8 @ 12" 1 #5 @ 9" CLASS AA 3" CLR. 1 1 1 3" CLR. (TYP.) 6" MIN. 5’-0" (TYP.) SLEEPER SLAB CEMENT CONCRETE CLASS AA 1 6" MIN. 1 1 SEE NOTE 4 3" 1 CLR. #8 @ 12" #5 @ 9" CEMENT CONCRETE CLR. 3" 3" 1 CLR. SEE NOTE 4 1 SEE NOTE 2 1’-0" 1 SLIDING SURFACE 9" 1 CONCRETE 2’-6" SEE NOTE 2 REFER TO RC-20M CLR. 1’-6" SLIDING SURFACE DEPTH OF TYPE E JOINT 3" 1’-6" TYPE 5 APPROACH SLAB - DETAIL 17 TYPE 5 APPROACH SLAB - DETAIL 16 END OF APPROACH SLAB END OF APPROACH SLAB ADJACENT TO FLEXIBLE PAVEMENT ADJACENT TO CONCRETE PAVEMENT (SEE NOTE 3) PAVEMENT RELIEF JOINT CONCRETE APPROACH SLAB FOR DETAILS NOT SHOWN REFER TO RC-24M REINFORCED CONCRETE 3" PAVEMENT (ROADWAY ITEM) CLR. PAVEMENT DEPTH OF 2’-6" CONCRETE NOTES 1’-0" 2’-6" 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. TROWEL SMOOTH AND PLACE 2 LAYERS OF 4 MIL. POLYETHYLENE SHEETING AS BOND BREAKER. 3. USE DETAIL 17 ONLY WHEN LIMITED MOVEMENT IS 4. STRUCTURAL BACKFILL, REFER TO RC-12M. SLIDING SURFACE 2’-6" 1 3" 1 CLR. CEMENT CONCRETE 1’-0" CLASS AA 1 #8 @ 12" #5 @ 9" PAVEMENT 1 ROADWAY 3" SEE NOTE 2 CLR. CEMENT REFER TO RC-24M FOR ADDITIONAL INFORMATION. CONCRETE 1’-6" CLASS AAAP ANTICIPATED IN THE ROADWAY OTHERWISE USE DETAIL 18. STRUCTURE CEMENT CONCRETE 1’-6" CLASS AAAP CLR. 2’-6" CLASS AAAP SHEET 9 (ROADWAY ITEM) STRUCTURE ROADWAY SEE DETAIL F, PAVEMENT 2’-6" 3" CONCRETE PAVEMENT CONCRETE APPROACH SLAB (ROADWAY ITEM) CONCRETE FLEXIBLE PAVEMENT CONCRETE APPROACH SLAB 1 1 SEE NOTE 4 3" CLR. (TYP.) 6" MIN. 6’-0" (TYP.) SLEEPER SLAB COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY STANDARD TYPE 5 APPROACH SLAB - DETAIL 18 END OF APPROACH SLAB BRIDGE APPROACH SLABS ADJACENT TO PAVEMENT RELIEF JOINT TYPE 5 - DETAILS 16, 17 AND 18 (ADJACENT TO ROADWAY) RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 23 OF 35 BD-628M 1’-3"* 5" MIN. DECK 8"* 1’-3"* PAVING MIN. SLAB PLUS HAUNCH 8"* MIN. NOTCH BRIDGE APPROACH SLAB CLASS AAAP CEMENT CONCRETE SEE DETAIL H, DECK SLAB 0" SHEET 10 AND NOTE 5. CLR. 0" NOTE 5. CLR. SHEET 10 AND BRIDGE APPROACH SLAB 8" MIN. CLASS AAAP CEMENT CONCRETE SEE DETAIL H, ROUGH 135 1’-6" 2" SLIDING CLR. SURFACE *** 1’-0" WATERSTOP 2" JOINT 135 SLIDING 1’-0" SURFACE *** CLR. " MIN. 1’-6" CONSTR WATERSTOP HAUNCH 1 ** ** BEAM NOTCH 1 1 (WITHOUT BEAM NOTCH (REFER TO 1 CAMBER) (REFER TO BD-661M) BD-661M) 1" PREFORMED " CLOSED CELL NEOPRENE SPONGE 8 " 1" PREFORMED SURFACE 9"* POLYSTYRENE 1 ’ 1 ’ TROWEL SMOOTH #6 PLACED CELLULAR 8 " CELLULAR POLYSTYRENE " CLOSED CELL NEOPRENE SPONGE #6 @ 9" #6 PLACED INSIDE HOOK TROWEL SMOOTH 9"* INSIDE HOOK SURFACE #6 @ 9" SEE ALTERNATE 2’-0" MIN. VOID REBAR DETAIL, THIS SHT. 6"* 1’-0"* PROVIDE 2’-0" GAP IN 1’-3" MIN. ALONG BACKWALL TO POLYETHYLENE SHEETING BACKWALL 2’-0"* ALONG BACKWALL TO 1’-3"* MIN. POLYETHYLENE SHEETING BACKWALL VOID DOWEL HOLE PROVIDE 2’-0" GAP IN 1’-3" MIN. AND REFER TO BD-661M JOINT OPENING MIN. DIAPHRAGM ALLOW FOR DRAINAGE "A" @ 68 F (REFER TO BD-656M) "A" @ 68 F ALLOW FOR DRAINAGE JOINT OPENING + 2" MIN. + 2" MIN. END OF BEAM END OF BEAM * MEASURED NORMAL TO ABUTMENT FRONT FACE 9" OF ABUTMENT P/S CONCRETE C L BEARINGS SPREAD BOX BEAM ** COAT WITH AN APPROVED EPOXY BONDING MIN. 9"* AND DOWEL 1’-3"* COMPOUND PRIOR TO PLACING APPROACH FRONT FACE SLAB CONCRETE P/S CONCRETE OF ABUTMENT *** 2 LAYERS OF 4 MIL. POLYETHYLENE SHEETING ADJACENT BOX BEAM MIN. MIN. C L BRGS. PLACED PARALLEL TO BEAMS AND SPACED BETWEEN BEAMS, SEE ALTERNATE REBAR DETAIL, THIS SHEET. TYPE 3 APPROACH SLAB - DETAIL 19 TYPE 3 APPROACH SLAB - DETAIL 20 APPROACH SLAB CONNECTED TO P/S CONCRETE ADJACENT BOX APPROACH SLAB CONNECTED TO THE SUPERSTRUCTURE (P/S CONCRETE SPREAD BOX BEAMS EXPANSION BEAMS WITH BACKWALL, FOR BEAM DEPTHS 33" AND GREATER AND CONCRETE END DIAPHRAGMS) WITH BACKWALL, FOR BEAM DEPTHS 39" AND GREATER SEE DETAIL H, WATERSTOP, SHEET 10 AND SEE BC-735M NOTE 5. NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. BURN OFF, TO TOP OF BEAM, REINFORCEMENT AND/OR THREADED FLANGE COUPLING 8 " LIFTING DEVICES PROTRUDING INTO APPROACH SLAB. 2"x2" FLANGE, 2" 1 ’ LENGTH AND 1" DIA. 3. DETAILS SHOWN MAY ONLY BE USED IF THE BEAM DEPTH IS EQUAL TO OR EXCEEDS THE DEPTHS INDICATED. IF REQUIRED BEAM DEPTH IS LESS THAN INDICATED PROVIDE #6 @ 9" " CLOSED CELL NEOPRENE SPONGE TYPE 1 OR TYPE 2 APPROACH SLAB. 4. FOR FORMING AND WATERSTOP DETAILS, SEE SHEET 3. 5. DETAIL O ON SHEET 35 MAY BE SPECIFIED AS AN ALTERNATE JOINT SEAL TYPE, AS DIRECTED BY THE 8 " 45(TYP.) DISTRICT BRIDGE ENGINEER. 2" (TYP.) 1 ’ - 6. SEE STANDARD DRAWING BC-767M FOR JOINT OPENING "A". 1" PREFORMED CELLULAR POLYSTYRENE COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY 1" #6 PLACED INSIDE HOOK #5 STANDARD 4" (TYP.) #4 OPTIONAL LOCATION BRIDGE APPROACH SLABS OF HOOK IF DEPTH 9"* ALLOWS TYPE 3 - DETAILS 19 AND 20 2’-0" MIN. 1’-3" MIN. DIAPHRAGM BACKWALL ALTERNATE REBAR DETAIL (P/S CONCRETE BOX BEAMS RECOMMENDED AUG. 31, 2012 RECOMMENDED WITH BACKWALL) AUG. 31, 2012 END OF BOX BEAM TO MATCH NOTCH SHOWN ABOVE FOR THIS ALTERNATE. CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 24 OF 35 BD-628M 1’-3"* 1’-3"* 8"* MIN. 8"* MIN. BRIDGE APPROACH SLAB DECK SLAB SHEET 10 AND NOTE 5. ROUGH CONSTR 2" 135 SLIDING CLR. SURFACE *** 1’-0" 4" ** (WITHOUT CAMBER) CAMBER) NEOPRENE SPONGE 8 " " CLOSED CELL CELLULAR 3" 2" ** 1 (REFER TO 1" PREFORMED CELLULAR POLYSTYRENE 1 ’ POLYSTYRENE 1 NEOPRENE SPONGE BEAM NOTCH 1" PREFORMED ’ " CLOSED CELL MIN. 1 BD-611M) MIN. BEAM NOTCH SLIDING 1’-0" 4" HAUNCH MIN. (REFER TO BD-662M) 135 SURFACE *** " MIN. 1 HAUNCH (WITHOUT 2" CLR. 8 " 1 WATERSTOP JOINT MIN. WATERSTOP JOINT 1’-6" CONSTR 1’-6" ROUGH " MIN. CLASS AAAP CEMENT CONCRETE SEE DETAIL H, 0" NOTE 5. 0" SHEET 10 AND CLR. DECK SLAB BRIDGE APPROACH SLAB 8" MIN. CLASS AAAP CEMENT CONCRETE SEE DETAIL H, CLR. 8" MIN. #6 PLACED TROWEL SMOOTH 9"* #6 PLACED #6 @ 9" TROWEL SMOOTH 9"* INSIDE HOOK SURFACE SURFACE #6 @ 9" INSIDE HOOK PROVIDE 2’-0" GAP IN 1’-3" MIN. 6"* 2’-0"* ALONG BACKWALL TO ALONG BACKWALL TO ALLOW FOR DRAINAGE ALLOW FOR DRAINAGE JOINT OPENING 2’-0"* "A" @ 68 F (REFER TO BD-656M) POLYETHYLENE SHEETING BACKWALL JOINT OPENING MIN. DIAPHRAGM PROVIDE 2’-0" GAP IN 1’-3" MIN. 6"* POLYETHYLENE SHEETING BACKWALL "A" @ 68 F MIN. DIAPHRAGM + 2" MIN. + 2" MIN. (REFER TO BD-611M) END OF BEAM 4"* * MEASURED NORMAL TO ABUTMENT MIN. 0" MIN. 6" MAX. 4"* ** COAT WITH AN APPROVED EPOXY BONDING MIN. COMPOUND PRIOR TO PLACING APPROACH END OF BEAM SLAB CONCRETE *** 2 LAYERS OF 4 MIL. POLYETHYLENE SHEETING P/S CONCRETE I-BEAM 9"* 1’-3"* MIN. MIN. STEEL PLACED PARALLEL TO BEAMS AND I-BEAM 9"* SPACED BETWEEN BEAMS, SEE ALTERNATE FRONT FACE 1’-3"* MIN. MIN. REBAR DETAIL, SHEET 24. C L BRGS. OF ABUTMENT FRONT FACE C L BRGS. OF ABUTMENT TYPE 3 APPROACH SLAB - DETAIL 21 TYPE 3 APPROACH SLAB - DETAIL 22 APPROACH SLAB CONNECTED TO THE SUPERSTRUCTURE APPROACH SLAB CONNECTED TO THE SUPERSTRUCTURE (P/S CONCRETE I-BEAMS AND CONCRETE END DIAPHRAGMS) (STEEL I-BEAMS AND CONCRETE END DIAPHRAGMS) WITH BACKWALL WITH BACKWALL - SEE TABLE A FOR MINIMUM BEAM DEPTHS FOR BEAM DEPTHS 40" AND GREATER TABLE A BEAM TYPE MINIMUM BEAM DEPTHS AASHTO TYPE I-BEAMS 63" PA BULB-TEE BEAMS 47.25" PA I-BEAMS 1 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION 1 THE FOLLOWING BEAMS ARE PERMITTED: NOTES 26/54, 24/60, 26/60 1. FOR NOTES, SEE SHEETS 1 AND 2. 24/63, AND 26/63 2. BURN OFF, TO TOP OF BEAM, REINFORCEMENT AND/OR BUREAU OF PROJECT DELIVERY STANDARD LIFTING DEVICES PROTRUDING INTO APPROACH SLAB. 3. DETAILS SHOWN MAY ONLY BE USED IF THE BEAM DEPTH IS BRIDGE APPROACH SLABS EQUAL OR EXCEEDS THE DEPTHS INDICATED IN TABLE A. IF REQUIRED BEAM DEPTH IS LESS THAN INDICATED PROVIDE TYPE 3 - DETAILS 21 AND 22 TYPE 1 OR TYPE 2 APPROACH SLAB. 4. FOR FORMING AND WATERSTOP DETAILS, SEE SHEET 3. (I-BEAMS WITH BACKWALL) 5. DETAIL O ON SHEET 35 MAY BE SPECIFIED AS AN ALTERNATE JOINT SEAL TYPE, AS DIRECTED BY THE DISTRICT BRIDGE ENGINEER. 6. SEE STANDARD DRAWING BC-767M FOR JOINT OPENING "A". RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 25 OF 35 BD-628M 1" FLUSH 5’-0" ADJACENT TO FLEXIBLE PAVEMENT EXPANSION OR CONCRETE PAVEMENT JOINT 6’-0" ADJACENT TO PAVEMENT RELIEF JOINT OUTSIDE FACE R CURB 5’-6" E OF BARRIER BARRIER C L 12" DIA. DUCTILE IRON OUTLET PIPE (ROADWAY ITEM) (ROADWAY ITEM) MIN. DESCRIPTION OF PLANS FOR DESCRIPTION OF DETAILS FOR TYPE 4 APPROACH SLABS TYPE 4 APPROACH SLAB PLAN DESCRIPTION SHEET NO. DETAIL DESCRIPTION SHEET NO. APPROACH SLAB ADJACENT TO FLEXIBLE INTEGRAL DRAIN TROUGH 1 1 EXTEND JOINT SEAL UP BARRIER FACE IN ACCORDANCE WITH BC-766M (TYP) " -6 2’ AB SL 0" ’INLET 10 N. I 6) (ROADWAY M TE NO ITEM) EE (S 9 PAVEMENT 26 LONG U-WINGS SHOULDER R PE EE SL WITH APPROACH SLAB AND APPROACH SLAB ADJACENT TO CONCRETE 2 9 PAVEMENT INTEGRAL DRAIN TROUGH WITH APPROACH SLAB 2 APPROACH SLAB ADJACENT TO PAVEMENT AND FLARED WINGS OR 27 3 9 RELIEF JOINT SHORT U-WINGS P/S CONCRETE ADJACENT BOX BEAMS WITH BACKWALL INTEGRAL DRAIN TROUGH 23 AND INTEGRAL DRAIN TROUGH FOR TOOTH DAM AND 29 WITHOUT APPROACH SLAB 3 #5 @ 12" NO APPROACH SLAB 28 AND FLARED WINGS OR #5 @ 12" SHORT U-WINGS P/S CONCRETE SPREAD BOX BEAMS AND CONCRETE END OPTIONAL KEYED 24 CONSTRUCTION JOINT N. MI " X. -7 MA 5’ " GH -4 OU R 7’ T N AI R D DIAPHRAGMS WITH BACKWALL AND INTEGRAL DRAIN 30 TROUGH FOR TOOTH DAM AND APPROACH SLAB SUPPORT (SEE DETAIL B, SHEET 5) BRIDGE HIGHWAY SUPPORT PEDESTAL SIDE SIDE 25’-0" 5" APPROACH SLAB O O 25 DIAPHRAGMS WITH BACKWALL AND INTEGRAL DRAIN 31 TROUGH FOR TOOTH DAM AND NO APPROACH SLAB BRIDGE WIDTH C L DRAIN TROUGH ROADWAY WIDTH C L CURB TO CURB WIDTH T. BO #5 @ 12" TOP P TO MATCH BRIDGE SKEW & #10 @ 9" BOT. #5 SKEW ANGLE TO 9" #8 @ 12" TOP & BOT. APPROACH SLAB @ SLEEPER SLAB P/S CONCRETE I-BEAMS AND CONCRETE END 7’-0" MAX. STEEL I-BEAMS AND CONCRETE END DIAPHRAGMS 26 WITH BACKWALL AND INTEGRAL DRAIN TROUGH 32 FOR TOOTH DAM AND APPROACH SLAB SUPPORT APPROACH WINGWALL SLAB WITH WITH BARRIER BARRIER 1" FLUSH LL WA CK BA P TO " T. 12 BO @ " 12 #5 @ #6 M AG HR AP DI TOP OF BARRIER JOINT GUTTER LINE BOTTOM OF OPTIONAL KEYED 5" SHOULDER UT KO OC BL CONSTRUCTION JOINT (SEE DETAIL B, SHEET 5) 4’-0" MAX. CONSTRUCTION JOINT EXPANSION V-NOTCH APPROACH SLAB TOP OF WINGWALL AND CONSTR JOINT (TYP.) 1" PREFORMED BEND LINE CELLULAR R S 5’-6" E JOINT OPENING OUTSIDE FACE S AS REQUIRED FOR MIN. P OF BARRIER 1" FLUSH TOOTH EXPANSION 1/2" OPEN JOINT IN BARRIER, EXPANSION JOINT PLAN 1 DAM (TYP. EACH SIDE) P BARRIER POLYSTYRENE (FAR SIDE OF WINGWALL) SEE BC-752M FOR DETAILS (TYP). WINGWALL SLEEPER SLAB (TYP. EACH SIDE) SECTION P-P TYPE 4 OMIT CAULKING COMPOUND IN AREA NOTES APPROACH SLAB WITH LONG U-WINGS OF SAW CUT FOR JOINT SEAL 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. FOR SECTION E-E, SEE SHEET 8. TOOTH EXPANSION DAM 3. FOR SECTION S-S, SEE SHEET 27. (SEE DRAIN TROUGH HIGHWAY DETAILS AND BC-762M) SIDE 25’-0" BRIDGE #10 @ 9" COMMONWEALTH OF PENNSYLVANIA SUBBASE PROVIDE 2 LAYERS OF 4 MIL. POLYETHYLENE SHEETING DIAPHRAGM IN GUIDE RAIL TRANSITION. 1, 2 AND 3 #5 @ 12" (BOTH ENDS) OUTFLOW PIPE MISSES TYPE 2-SC POSTS RELIEF JOINT (ROADWAY ITEMS) SEE DETAILS 3" #6 @ 12" 2 1’-4" (TYP) 6. INLET TO BE LOCATED SUCH THAT ITS PAVEMENT OR PAVEMENT CLR. " 3" CLR CLR. #5 @ 12" 23 THRU 26 1’-6" SHEETS 28 - 34. PAVEMENT, FLEXIBLE (TYP) SEE DETAILS 5. FOR DRAIN TROUGH DETAILS, SEE PAY LIMIT: CONCRETE 2’-9" SIDE 4. FOR SECTION R-R, SEE SHEET 33. DEPARTMENT OF TRANSPORTATION (ROADWAY BUREAU OF PROJECT DELIVERY ITEM) UNDERNEATH APPROACH SLAB SLEEPER SLAB SUBSURFACE DRAIN (ROADWAY ITEM)(REFER TO INSTRUCTIONS STANDARD TO DESIGNER NOTES) INTEGRAL DRAIN TROUGH BACKWALL BRIDGE APPROACH SLABS (SEE DRAIN TROUGH DETAILS) TYPE 4 - PLAN 1 AND SECTION PAY LIMITS FOR BRIDGE APPROACH SLAB QUANTITIES SECTION O-O RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 26 OF 35 BD-628M 10’-0" BEND #5 TOP MIN. LINE #10 BOT. (SEE NOTE 6) (AS REQ’D.) C JOINT OR CONCRETE PAVEMENT 6’-0" ADJACENT TO PAVEMENT RELIEF JOINT 8 C SHOULDER E 5’-0" ADJACENT TO FLEXIBLE PAVEMENT " OF BARRIER 8" EXPANSION CURB 1" FLUSH OUTSIDE FACE R BARRIER CURB (ROADWAY ITEM) INLET EXTEND JOINT SEAL UP BARRIER FACE (ROADWAY IN ACCORDANCE WITH BC-766M (TYP) 0" ’10 N. 7) MI TE NO EE S ( C L 12" DIA. DUCTILE IRON OUTLET PIPE (ROADWAY ITEM) ITEM) #5 @ 12" C L C L DRAIN TROUGH BRIDGE HIGHWAY SUPPORT PEDESTAL SIDE SIDE 25’-0" APPROACH SLAB O O 5" LL WA CK BA @ #5 @ #6 M AG HR AP DI " -6 2’ OPTIONAL KEYED 5" SHOULDER UT KO OC BL CONSTRUCTION JOINT P TO " T. 12 BO " 12 BRIDGE WIDTH MATCH BRIDGE SKEW ROADWAY WIDTH APPROACH SLAB SKEW ANGLE TO CURB TO CURB WIDTH 7’-0" MAX. #5 @ 12" TOP (SEE DETAIL B, SHEET 5) #10 @ 9" BOT. CONSTRUCTION JOINT N. MI " X. -7 MA 5’ " GH -4 OU R 7’ T N AI R D SLEEPER SLAB OPTIONAL KEYED #8 @ 12" TOP & BOT. AB SL ER EP E SL 9" @ T. #5 BO & P TO #5 @ 12" CONSTRUCTION JOINT (SEE DETAIL B, SHEET 5) SEE DETAIL C, 4’-0" MAX. 1/2" OPEN JOINT IN BARRIER, SHEET 5 (TYP.) (TYP.) SEE BC-752M FOR DETAILS (TYP). OMIT CAULKING COMPOUND IN AREA NOTES S JOINT OPENING E EDGE OF 1’-4 R OUTSIDE FACE OF BARRIER AS REQUIRED FOR APPROACH SLAB S BARRIER " OF SAW CUT FOR JOINT SEAL 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. FOR SECTION E-E, SEE SHEET 8. 3. FOR SECTION O-O, SEE SHEET 26. 4. FOR SECTION R-R, SEE SHEET 33. 5. FOR DRAIN TROUGH DETAILS, SEE SHEETS 28 - 34. TOOTH EXPANSION 10’-0" MIN. DAM (TYP. EACH SIDE) BEND LINE 6. PROVIDE TYPE 2-SC GUIDE RAIL WITH POSTS AT 3’-1" SPA. #5 TOP ALONG CURB AFTER APPROACH END TRANSITION. #10 BOT. PLAN 2 7. INLET TO BE LOCATED SUCH THAT ITS OUTFLOW PIPE MISSES (AS REQ’D.) TYPE 2-SC POSTS IN GUIDE RAIL TRANSITION. TYPE 4 APPROACH SLAB WITH FLARED WINGS OR SHORT U-WINGS BRIDGE DECK ABUTMENT APPROACH SLAB AND BARRIER WITH WITH BARRIER BARRIER JOINT OPENING AS REQUIRED FOR TOOTH EXPANSION DAM TOP OF BARRIER SEE DETAIL BEND LINE M OR N, SHEET 32 COMMONWEALTH OF PENNSYLVANIA GUTTER LINE V-NOTCH DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY STANDARD FF BACKWALL SLEEPER SLAB INTEGRAL DRAIN BOTTOM OF TROUGH (SEE DRAIN APPROACH SLAB BRIDGE APPROACH SLABS TYPE 4 - PLAN 2 TROUGH DETAILS) SECTION S-S RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 27 OF 35 BD-628M BARRIER 1" FLUSH EXPANSION JOINT CURB R (ROADWAY ITEM) (SEE NOTE 5) NOTE: BLOCKOUT REFER TO BC-762M FOR ADDITIONAL INFORMATION 9" " DIA. Q Q 9" W " LP AIR HOLES INLET (ROADWAY 1" 1"x 1" SLOTTED (TYP) HOLES FOR " DIA. STUDS SPA. @ " 10’-0" MIN. (SEE NOTE 6) U POINTS BTW. CLIPS TOOTH P L H.S. BOLTS (TYP.) " DIA. x 16" t ALTERNATELY (TYP) ITEM) (TYP) SHOULDER @ 6" STUDS (TYP) C L 12" DIA. DUCTILE IRON SIDE SIDE DECK SLAB 1’-6" MIN. " DIA. x 10" STUDS (TYP) " LP 2" MIN 6" MAX STEEL " DRIP 1" PREFORMED U NOTCH (TYP) @ 4’-0" MAX (TYP) POLYSTYRENE PROVIDE 1" DIA. HOLES FOR REINFORCEMENT (TYP) TROWEL SMOOTH SURFACE LL WA CK BA WT 18x75 CLIP CELLULAR 6" 6" 2’-6" MIN. SUPPORT PEDESTAL TYP 2"x " GALVANIZED STEEL 9" MIN @ 68 F (ASTM A709, GR.36 OR 50) 3" MIN @ -10 F BATTEN SECURED TO CONCRETE WITH SELF-TAPPING STAINLESS M AG HR AP DI DRAIN TROUGH MATERIAL STEEL CONCRETE SCREWS, (SECTION 1020.2(h) PUB. 408) " @ 18" MAX. (TYP.) ATTACHED TO CONCRETE WITH 4’-0" MAX. CONSTRUCTION JOINT SHOULDER (ATTACHMENT INCIDENTAL TO UT KO OC BL 7" ADHESIVE AS RECOMMENDED BY PERMANENT STRUCTURE) 4-" DIA. MIN. DRAIN TROUGH MANUFACTURER. ANCHOR BOLTS W/ NUTS AND WASHERS NON SHRINK GROUT CHAMFERS (TYP.) Q 4" EMBEDMENT (TYP.) HIGHWAY TYP STAINLESS BRIDGE WIDTH C L C L DRAIN TROUGH BRIDGE ROADWAY WIDTH 7’-0" MAX. CURB TO N. MI 0" . -1 AX ’ M 4 " GH -7 OU R 6’ T N AI R D CURB WIDTH OUTLET PIPE (ROADWAY ITEM) Q 1’-3" 2’-1" MIN 1’-6" MIN WITHOUT APPROACH SLAB SUPPORT MIN 3’-10" MAX 2’-3" MAX WITH 9" APPROACH SLAB SUPPORT BARRIER BACKWALL R T T JOINT OPENING AS REQUIRED FOR TOOTH EXPANSION DAM (TYP. EACH SIDE) TOOTH EXPANSION DAM ANCHORAGE DETAIL PLAN 3 TYPE 4 NO APPROACH SLAB WITH FLARED WINGS TOOTH P L OR SHORT U-WINGS BRIDGE DECK U-WING AND BARRIER WITH BARRIER WT18x75 CLIP @ 4’-0" MAX (TYP) JOINT OPENING AS TOP OF BARRIER TYP REQUIRED FOR TOOTH EXPANSION DAM " LP SEE DETAIL STAINLESS M OR N, BEND LINE STEEL SHEET 32 GUTTER LINE COMMONWEALTH OF PENNSYLVANIA V-NOTCH " DEPARTMENT OF TRANSPORTATION SECTION U-U BUREAU OF PROJECT DELIVERY FF BACKWALL STANDARD NOTES INTEGRAL DRAIN TROUGH (SEE DRAIN TROUGH DETAILS) BRIDGE APPROACH SLABS 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. FOR SECTIONS R-R, SEE SHEET 33. TYPE 4 - PLAN 3 3. FOR SECTIONS Q-Q, SEE SHEET 34. 4. FOR DRAIN TROUGH DETAILS, SEE SHEETS 28 - 34. 5. PROVIDE TYPE 2-SC GUIDE RAIL WITH POSTS AT 3’-1 1/2 " SPA. ALONG CURB AFTER APPROACH END TRANSITION. SECTION T-T 6. INLET TO BE LOCATED SUCH THAT ITS OUTFLOW PIPE MISSES RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHEET 28 OF 35 TYPE 2-SC POSTS IN GUIDE RAIL TRANSITION. CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-628M 6’- 1" MAX. 3" EA4 BARS 3" CLR @ 1’-0" MAX. CLR EACH FACE (TOP) BOTTOM OF INTEGRAL 3" 9" CLR (TYP) DRAIN TROUGH 3" CEMENT 3’-7" MIN. BACKWALL CONCRETE CLASS AAAP 1 CLASS AA ** SLIDING SURFACE *** CEMENT CONCRETE 1’-6" SLAB PLUS HAUNCH DECK SLAB 5" MIN. DECK 1’-3" MIN. 1 BEAM NOTCH CLASS AA CEMENT CONCRETE CLASS A BD-661M) CEMENT CONCRETE (REFER TO 3" EA4 BARS (TYP.) + 2" MIN. @ 1’-0" MAX. (TYP.) 3" CONSTR JT. o @ 68 F A4 BARS KEYED JOINT OPENING @ 1’-0" MAX. MIN. MIN. 1’-3"* 1’-0" DOWEL HOLE FOOTING CHAMFER (TYP.) SURFACE CONSTR JT. LAP TROWEL SMOOTH VOID ABUTMENT KEYED 3" x 3" MIN. 3’-10" MAX. MIN. 1’-9" 1’-6" 2’-1" MIN. 2-0" 4’-0" MAX. CELLULAR POLYSTYRENE 2’-0" MIN. 1" PREFORMED INTEGRAL CONCRETE END OF BEAM DRAIN TROUGH WITH TOOTH DAM 1’-3" MIN. BACKWALL FRONT FACE 9" DRAIN TROUGH C L BEARINGS OF ABUTMENT 1’-0"x1’-0" OPENING SUPPORT PEDESTALS MIN. FOR STRUCTURE AND DOWEL P/S CONCRETE @ 7’-0" MAX FOUNDATION DRAIN EXTENDED TO (IF PRESENT), CUT REINF. AS NEEDED ABUTMENT FOOTING A4 BARS ADJACENT BOX BEAM @ 1’-0" MAX. BONDING COMPOUND PRIOR TO LAP 1’-3" * MEASURED NORMAL TO ABUTMENT ** COAT WITH AN APPROVED EPOXY MIN. EACH FACE (BOT.) 3" TYPE 4 APPROACH SLAB - DETAIL 23 PLACING DECK SLAB CONCRETE *** 2 LAYERS OF 4 MIL. P/S CONCRETE ADJACENT BOX BEAMS WITH BACKWALL POLYETHYLENE SHEETING FOR BEAM DEPTHS 33" AND GREATER (SHOWN WITH FLEXIBLE PAVEMENT ADJACENT TO TOOTH DAM) 1’-3" MIN. 3" F4 BARS 3" CLR @ 1’-0" MAX. CLR EACH FACE BACKWALL EA4 BARS PEDESTAL REINFORCEMENT ELEVATION @ 1’-0" MAX EACH FACE (TOP) A4 BARS (BOT) OR EA4 BARS (TOP) 3" CLR SEE NOTE 5 (TYP) 1’-6" @ 1’-0" MAX COMMONWEALTH OF PENNSYLVANIA FRONT FACE BACKWALL DEPARTMENT OF TRANSPORTATION A4 BARS @ 1’-0" MAX EACH FACE (BOT.) BUREAU OF PROJECT DELIVERY NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. STANDARD 2. BURN OFF, TO TOP OF BEAM, REINFORCEMENT AND/OR LIFTING DEVICES PROTRUDING INTO APPROACH SLAB. 3. DETAILS SHOWN MAY ONLY BE USED IF THE BEAM DEPTH BRIDGE APPROACH SLABS IS EQUAL TO OR EXCEEDS THE DEPTHS INDICATED. IF REQUIRED BEAM DEPTH IS LESS THAN INDICATED PROVIDE PEDESTAL REINFORCEMENT SECTION TYPE 4 - DETAIL 23 TYPE 1 OR TYPE 2 APPROACH SLAB. 4. SEE STANDARD DRAWING BC-762M FOR JOINT OPENING o. (P/S CONCRETE BOX BEAMS WITH BACKWALL) 5. CONTRACTOR HAS THE OPTION OF FORMING AND POURING THE SUPPORT PEDESTALS INTEGRAL WITH THE ABUTMENT STEM OR PROVIDING A CONSTRUCTION JOINT WITH PROJECTING REINFORCEMENT. RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 29 OF 35 BD-628M BRIDGE APPROACH SLAB SEE DETAIL H, 8" MIN. EA6 BARS @ 6" CLASS AA CEMENT CONCRETE SHEET 10 AND 4" DECK SLAB NOTE 5. 9"* BEAM NOTCH (WITHOUT 1 (REFER TO CAMBER) MIN. JOINT CEMENT 1’-3" CONCRETE ** CLASS AAAP CONSTR BOND BREAKER, 2-PLY BIT. PAPER 1’-4" HAUNCH SLIDING SURFACE *** 8" ROUGH 1’-6" " MIN. DECK SLAB CLR 3-EA6 BARS (TOP & BOT) BACKWALL 1 BD-661M) 3-EA6 CELLULAR 3’-10" MAX. POLYSTYRENE TROWEL SMOOTH 3" x 3" SURFACE CHAMFER (TYP.) JOINT OPENING o @ 68 F (REFER TO BD-656M) + 2" MIN. KEYED CONSTR JT. (TYP.) 1’-3" MIN. INTEGRAL CONCRETE BACKWALL MIN. 2’-0"* MIN DIAPHRAGM 1’-0" VOID (TYP.) EA5 BARS @ 12" 2’-3" 2’-1" MIN. EA5 BARS @ 6" 2" CLR MAX. EACH FACE NEOPRENE SPONGE 1" PREFORMED 3" CLR CLASS AA CEMENT CONCRETE 8"* 4’-0" MAX. " CLOSED CELL 2’-0" MIN. 1’-0"* EA5 CLOSED HOOPS @ 6" 3-EA6 3" " DIA. CLR ANCHOR BOLTS DRAIN TROUGH EA6 BARS @ 6" FOR TOOTH DAM WITH TOOTH DAM END OF BEAM EA5 BARS @ 6" MAX. (TOP & BOT) DRAIN TROUGH 9"* 1’-3"* SUPPORT PEDESTALS MIN. MIN. @ 7’-0" MAX. FRONT FACE EXTENDED TO OF ABUTMENT ABUTMENT FOOTING C L BRGS. P/S CONCRETE SPREAD BOX BEAM DRAIN TROUGH REINFORCEMENT DETAIL * MEASURED NORMAL TO ABUTMENT (SHOWN WITH APPROACH SLAB SUPPORT / PAVING NOTCH) ** COAT WITH AN APPROVED EPOXY BONDING COMPOUND PRIOR TO TYPE 4 APPROACH SLAB - DETAIL 24 PLACING DECK SLAB CONCRETE *** 2 LAYERS OF 4 MIL. P/S CONCRETE SPREAD BOX BEAMS AND CONCRETE END DIAPHRAGMS POLYETHYLENE SHEETING WITH BACKWALL FOR BEAM DEPTHS 39" AND GREATER (SHOWN WITH APPROACH SLAB ADJACENT TO TOOTH DAM) BLOCKOUT TRANSVERSE SLAB ES6 BARS TOP & BOT REINFORCEMENT (PLACED PARALLEL TO LONGITUDINAL SLAB 3" ES6 BARS TO EXTEND MIN. 3’-6" MIN. BEYOND DIAPH. 6" REINFORCEMENT 3" SKEW) TIED TO STUDS NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. BURN OFF, TO TOP OF BEAM, REINFORCEMENT AND/OR LIFTING DEVICES PROTRUDING INTO APPROACH SLAB. 3. DETAILS SHOWN MAY ONLY BE USED IF THE BEAM DEPTH BRGS. IS EQUAL TO OR EXCEEDS THE DEPTHS INDICATED. IF SLAB TYPE 1 OR TYPE 2 APPROACH SLAB. 1’-6" 4. SEE STANDARD DRAWING BC-762M FOR JOINT OPENING CONSTR. JT. o. 5. DETAIL O ON SHEET 35 MAY BE SPECIFIED AS AN ALTERNATE JOINT SEAL TYPE, AS DIRECTED BY THE DISTRICT BRIDGE ENGINEER. HAUNCH COMMONWEALTH OF PENNSYLVANIA BEAM (TYP) CEMENT CONCRETE (TYP) CONCRETE CLASS AAA CLASS AA CEMENT REQUIRED BEAM DEPTH IS LESS THAN INDICATED PROVIDE ES6 BAR ES6 BARS @ 9" (BTWN BMS) DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY (PLACED PARALLEL TO SKEW) ED4 BARS @ 9" STANDARD (BTWN BMS) ES6 BARS, SPACING AS REQUIRED BY DESIGN BRIDGE APPROACH SLABS TYPE 4 - DETAIL 24 CONC. ABUT. DIAPH. BKWL. DECK SLAB REINFORCEMENT DETAIL (P/S CONCRETE BOX BEAMS WITH BACKWALL) RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 30 OF 35 BD-628M EA6 BARS @ 6 8" MIN. 4" DECK SLAB JOINT (WITHOUT CEMENT SLIDING SURFACE *** CONCRETE ** CONSTR 1 HAUNCH CLASS AAAP ROUGH 1 1’-6" " MIN. DECK SLAB CLR 3-EA6 BARS (TOP & BOT) 1’-3" MIN. BACKWALL 3’-10" MAX. 3" x 3" TROWEL SMOOTH JOINT OPENING o @ 68 F (REFER TO BD-656M) + 2" MIN. KEYED CONSTR JT. (TYP.) INTEGRAL CONCRETE DRAIN TROUGH WITH TOOTH DAM 4"* MIN. 2’-0"* MIN DIAPHRAGM CHAMFER (TYP.) 1’-0" SURFACE (TYP.) EA5 BARS @ 6 CLASS AA CEMENT CONCRETE 1’-6" 2’-1" MIN. CELLULAR POLYSTYRENE 4’-0" MAX. 1" PREFORMED 2’-0" MIN. 3" CLR (REFER TO BD-662M) CLR 2-EA6 3" " DIA CLR ANCHOR BOLTS EA6 BARS @ 6 FOR TOOTH DAM EA5 BARS @ 6" MAX. 1’-3" MIN. MIN. 2" EACH FACE BEAM NOTCH EA5 BARS @ 12" MAX. CAMBER) (TOP & BOT) BACKWALL DRAIN TROUGH SUPPORT PEDESTALS END OF BEAM @ 7’-0" MAX. EXTENDED TO ABUTMENT FOOTING P/S CONCRETE I-BEAM 9"* 1’-3"* MIN. MIN. DRAIN TROUGH REINFORCEMENT DETAIL FRONT FACE OF ABUTMENT (SHOWN WITHOUT APPROACH SLAB SUPPORT / PAVING NOTCH) C L BRGS. * MEASURED NORMAL TO ABUTMENT TYPE 4 APPROACH SLAB - DETAIL 25 P/S CONCRETE I-BEAMS AND CONCRETE END DIAPHRAGMS ** COAT WITH AN APPROVED EPOXY BONDING COMPOUND PRIOR TO PLACING DECK SLAB CONCRETE WITH BACKWALL - SEE TABLE A FOR MINIMUM BEAM DEPTHS *** 2 LAYERS OF 4 MIL. (SHOWN WITH FLEXIBLE PAVEMENT ADJACENT TO TOOTH DAM) POLYETHYLENE SHEETING NOTES TABLE A 1. FOR NOTES, SEE SHEETS 1 AND 2. 2. BURN OFF, TO TOP OF BEAM, REINFORCEMENT AND/OR BEAM TYPE MINIMUM LIFTING DEVICES PROTRUDING INTO APPROACH SLAB. 3. DETAILS SHOWN MAY ONLY BE USED IF THE BEAM DEPTH BEAM DEPTHS IS EQUAL TO OR EXCEEDS THE DEPTHS INDICATED. IF REQUIRED BEAM DEPTH IS LESS THAN INDICATED PROVIDE AASHTO TYPE I-BEAMS 63" PA BULB-TEE BEAMS 47.25" PA I-BEAMS 1 TYPE 1 OR TYPE 2 APPROACH SLAB. 1 4. SEE STANDARD DRAWING BC-762M FOR JOINT OPENING o. THE FOLLOWING BEAMS ARE PERMITTED: 26/54, 24/60, 26/60, 24/63, AND 26/63 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY STANDARD BRIDGE APPROACH SLABS TYPE 4 - DETAIL 25 (P/S CONCRETE I-BEAMS WITH BACKWALL) RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 31 OF 35 BD-628M BRIDGE APPROACH SLAB 8" MIN. CLASS AA CEMENT CONCRETE SEE DETAIL H, DECK SLAB SHEET 10 AND 1’-6" " MIN. ** HAUNCH 1 (WITHOUT BEAM NOTCH CAMBER) SLIDING BOND BREAKER, SURFACE *** 2-PLY BIT. PAPER 1’-4" ROUGH CONSTR JOINT DECK SLAB NOTE 4. 1 (REFER TO CEMENT CONCRETE CHAMFER (TYP.) INTEGRAL CONCRETE 2’-0"* JOINT OPENING DRAIN TROUGH MIN. DIAPHRAGM o @ 68 F WITH TOOTH DAM (REFER TO BD-611M) + 2" MIN. 1’-6" W 1" (TYP.) TROUGH 7" W 7" OPENING CLASS AA (TYP.) MIN. 1’-0" SURFACE KEYED CLR. TROUGH OPENING 3" x 3" TROWEL SMOOTH CONSTR JT. 1" MIN 1’-9" POLYSTYRENE " 3’-10" MAX. GALVANIZED STEEL PLATE 3 CELLULAR 2’-3" (TYP.) 2’-1" MIN. 4" 1" PREFORMED " REMOVABLE 4’-0" MAX. 9"* 2’-0" MIN. 3" MIN. BD-611M) DETAIL N DRAIN TROUGH END VIEW (BURIED ENDS) 4"* 0" MIN. 1’-3" MIN. MIN. 6" MAX. DRAIN TROUGH BACKWALL SUPPORT PEDESTALS C L TROUGH @ 7’-0" MAX. END OF BEAM EXTENDED TO ABUTMENT FOOTING STEEL I-BEAM 9"* 1’-3"* MIN. MIN. FRONT FACE 3 - THREADED OF ABUTMENT INSERTS (TYP.) 1’-3" 1’-6" BACK- TROUGH WALL WALL C L BRGS. " REMOVABLE GALVANIZED 3 - " DIA. GALVANIZED STEEL PLATE A325 BOLTS WITH GALVANIZED 1" TYPE 4 APPROACH SLAB - DETAIL 26 * MEASURED NORMAL TO ABUTMENT 1" 7" TROUGH ** COAT WITH AN APPROVED EPOXY 7" OPENING BONDING COMPOUND PRIOR TO STEEL I-BEAMS AND CONCRETE END DIAPHRAGMS WITH WASHERS (TYP.) TROUGH OPENING NOTE: PLACING DECK SLAB CONCRETE BACKWALL FOR BEAM DEPTHS 40" AND GREATER + 1’-3" STEEL PLATE AND BOLTS *** 2 LAYERS OF 4 MIL. (SHOWN WITH APPROACH SLAB ADJACENT TO TOOTH DAM) SECTION W-W POLYETHYLENE SHEETING INCIDENTAL TO COST OF TOOTH EXPANSION DAM. HEAVY WELDED GALVANIZED STEEL GRATE 2" x " BARS @ 2" MAX. C-C WITH " DIA. CROSS BARS @ 4" C-C NOTES 1. FOR NOTES, SEE SHEETS 1 AND 2. SEE DETAIL N V-NOTCH FOR BURIED ENDS 2. DETAILS SHOWN MAY ONLY BE USED IF THE BEAM DEPTH C L TROUGH GUTTER LINE IS EQUAL TO OR EXCEEDS THE DEPTHS INDICATED. IF 1’-6" OR REQUIRED BEAM DEPTH IS LESS THAN INDICATED PROVIDE DECK SLAB APPROACH SLAB 1" MIN. 1" CLR. 1’-9" TROUGH OPENING 1’-6" " 3 1’-3" 2’-3" BACK- TROUGH WALL WALL TYPE 1 OR TYPE 2 APPROACH SLAB. 3. SEE STANDARD DRAWING BC-762M FOR JOINT OPENING 1" CLOSED CELL NEOPRENE SPONGE 1" CLOSED CELL o. 4. DETAIL O ON SHEET 35 MAY BE SPECIFIED AS AN ALTERNATE JOINT SEAL TYPE, AS DIRECTED BY THE DISTRICT BRIDGE ENGINEER. NEOPRENE SPONGE V (TYP.) V 4" TOP OF WINGWALL COMMONWEALTH OF PENNSYLVANIA 1" (TYP.) " TRIM BAR (TYP.) WINGWALL 1’-3" (TYP.) DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY 2 - " DIA. GALVANIZED 2 - THREADED HEX. HEAD BOLTS WITH 5" INSERTS (TYP.) STANDARD 1" CLOSED CELL 1’-3" (TYP.) NEOPRENE SPONGE 1" 1" DIA. GALVANIZED WASHERS (TYP.) REMOVABLE 7" TROUGH 7" OPENING #5 @ 12" DOWELS 7" TROUGH OPENING 7" BRIDGE APPROACH SLABS GALVANIZED STEEL GRATE TYPE 4 - DETAIL 26 TROUGH OPENING CHEEKWALL/ CURTIN WALL WINGWALL + 1’-3" (STEEL BEAMS WITH BACKWALL) NOTE: DETAIL M - DRAIN TROUGH END VIEW SECTION V-V STEEL GRATE AND BOLTS INCIDENTAL TO COST OF TOOTH EXPANSION DAM. RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHEET 32 OF 35 (EXPOSED ENDS) CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-628M 4-0" 3’-0" MAX. SPA. BENT PLATE (TYP.) C L SUPPORT TOP OF WALL FOR DRAIN TROUGH OUTSIDE FACE CONSTR JOINT OF BARRIER (RAKED FINISH) FOR TOOTH P L AND BOTTOM OF APPROACH SLAB (PARALLEL WITH ROADWAY, SEE NOTE 2) OUTSIDE FACE TOP OF APPROACH SLAB OF BARRIER (TYP.) AND TOOTH PLATE 1’-6" OF WINGWALL (TYP.) (TYP.) 1’-0" 2" CLR. 2"x " GALVANIZED STEEL #5 @ 12" (TYP.) TERMINATION BAR SECURED TO (TYP.) C L 12" DIA. DUCTILE IRON #5 @ 12" (TYP.) OUTLET PIPE (ROADWAY ITEM) 2’-6" MIN TROUGH OPENING 1’-6" RUBBERIZED TROUGH MATERIAL EMBED (TYP) SEE DETAIL M OR N (SECTION 1020.2(h) PUB. 408) CONCRETE WITH SELF-TAPPING ATTACHED TO CONCRETE WITH STAINLESS STEEL CONCRETE SLOPE TO DRAIN ENDWALL APPROVED ADHESIVE 2 % MIN. SCREWS, " @ 18" MAX. (TYP.) 5’-6" MAX. LEVEL FOR WIDTH 1’-6" MIN. SEE DETAIL M OR N 3’-6" MIN. TROUGH OPENING 1’-6" ENDWALL 1’-0" MIN. 1’-0" SLOPE BOTTOM OF TROUGH MIN. TO PIPE INVERT 1" CLOSED CELL NEOPRENE SPONGE 1" CLOSED CELL NEOPRENE SPONGE 1’-6" MIN. STRUCTURE BACKFILL MATERIAL #5 @ 12" WINGWALL (TYP.) DOWELS TOP OF WINGWALL (IF REQUIRED) (TYP.) LEVEL (TYP.) 7’-0" MAX. WINGWALL SECTION R-R (IF REQUIRED) (DRAIN TROUGH) C L DRAIN TROUGH 4’-0" MAX. SUPPORT PEDESTAL (TYP.) (TYP.) (TYP.) C L 12" DIA. DUCTILE IRON OUTLET PIPE (ROADWAY ITEM) PROVIDE SPOT ELEVATIONS DRAIN TROUGH SUPPORT BEGIN OR END PEDESTAL (TYP.) BRIDGE STATION AT GUTTER LINE AND BREAK ADJUST DRAIN TROUGH REINFORCEMENT TO CLEAR WT 18x75 SUPPORT ANCHOR BOLTS AND BRACKET AND ANCHOR SUPPORT BRACKETS (TYP.) BOLTS (TYP.) 1’-6" TROUGH WALL WITHOUT APPROACH SLAB SUPPORT IN SLOPE POINTS FOR THE BOTTOM OF TROUGH AND TOP OF BACKWALL OR TROUGH WALL 2’-3" TROUGH WALL WITH APPROACH SLAB SUPPORT R R 6" SLOPE TO (TYP.) DRAIN 9" MIN. @ 68 F 2’-1" MIN. JOINT OPENING * W @ 68 F 1’-3" MIN. BACKWALL * 3’-10" MAX. JOINT OPENING o @ 68 F * END DIAPHRAGM + 2" MIN. 6" C/C NOTES (TYP.) 1. FOR NOTES, SEE SHEETS 1 AND 2. BLOCKOUT CONSTRUCTION JOINT 2. FOR DETAILS M AND N, SEE SHEET 32. 3. DESIGNER MAY ADJUST AS REQUIRED TO SIMPLIFY FABRICATION AND CONSTRUCTION. GUTTER LINE (TYP.) BREAK IN SLOPE (TYP.) CONSTRUCTION BASELINE 4. STAINLESS STEEL PLATE, STUDS, ANCHOR BOLTS, RUBBERIZED TROUGH MATERIAL, GALVANIZED STEEL TERMINATION BARS, SELF-TAPPING STAINLESS STEEL CONCRETE SCREWS, NON SHRINK GROUT AND ANY OTHER ITEMS SHOWN ARE INCIDENTAL TO THE * TO BE ADJUSTED FOR INSTALLATION TEMPERATURE TOOTH DAM SUPPORT PLAN COST OF THE TOOTH EXPANSION DAM. FOR SPECIFIED MOVEMENT CLASSIFICATION. COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY STANDARD BRIDGE APPROACH SLABS TYPE 4 - DRAIN TROUGH DETAILS 1 RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 33 OF 35 BD-628M 1 Q 2 6" x 4" x " MIN. ANGLE SPACED REMOVABLE ANCHOR (TYP.) 3 " DIA. STUD TO LIMIT DEFLECTION OF DAM BETWEEN DO NOT USE PERCUSSION DRILL BOLT (TYP.) SUPPORTS TO " MAX. TO INSTALL ANCHOR. AFTER REMOVAL, FILL HOLE WITH WITH 3" DIA. * PLATE WASHERS LIMITS OF BLOCKOUT 1" x 4" SLOTTED TOP AND BOTTOM APPROVED NONSHRINK MORTAR HOLES FOR " DIA. PER PUB. 408 SECT. 1001.2(e) STUD BOLTS (TYP.) " (TYP.) TACK WELD (TYP.) (TYP.) SLOPE DOWN "/FT COAT WITH AN APPROVED EPOXY SHIM AS DECK SLAB 6" MIN. 1’-6" MIN. SHIMS (TYP.) REQUIRED TO PREVENT ROTATION B BONDING COMPOUND PRIOR TO S G R * W PLACING DECK SLAB CONCRETE * FF ABUT TO BE ADJUSTED FOR INSTALLATION TEMPERATURE WT18x75 CLIP FOR SPECIFIED MOVEMENT CLASSIFICATION. Q ** CONTRACTOR MAY USE AN ALTERNATE SCHEME WITH THE APPROVAL OF THE DISTRICT BRIDGE ENGINEER @ 4’-0" MAX. 1’-3" MIN. BACKWALL * 2" MIN. (TYP.) 9" MIN. 6" MAX. @ 68 F FF WING OR DISTRICT STRUCTURE CONTROL ENGINEER " FLUSH EXP JT ** CONCEPTUAL INSTALLATION SCHEME SAFETY WING PLAN MEASURED ALONG 5’-10" JOINT INSTALLATION NOTES: OF BARRIER 1. CAST ANCHOR BOLTS INTO INTEGRAL CONCRETE DRAIN TROUGH. BEND LINE 2. INSTALL AND ADJUST FIXED PORTION OF TOOTH DAM ON TROUGH WALL TO THE PROPER LINE AND GRADE. 3. THE SURFACE OF THE BLOCKOUT MUST BE COMPLETELY CLEAN WHEN THE JOINT IS INSTALLED. 1’-8" EC4 BARS @ 6 4. SUPPORT MOVEABLE PORTION OF TOOTH DAM IN THE BLOCKOUT FROM THE DECK SLAB AND FIXED EC4 BARS @ 6 GUTTER LINE PORTION OF THE TOOTH DAM (SEE CONCEPTUAL INSTALLATION SCHEME). A’ EC6 BARS 5. ADJUST MOVEABLE PORTION OF TOOTH DAM TO THE PROPER LINE AND GRADE WITH THE JOINT OPENING (W) SET WITH RESPECT TO THE INSTALLATION TEMPERTURE SHOWN ON THE PLANS. EC4 6. DURING ASSEMBLY INSTALLATION TIGHTEN ANCHOR 1 AND BOTH NUTS ON STUD BOLTS 2 AND 3 BARS EC6 BARS GUTTER EC5 BARS EC5 BARS OF BARRIER MAKING SURE THE JOINT OPENING (W) REFLECTS THE INSTALLATION TEMPERATURE. 7. IMMEDIATELY AFTER BLOCKOUT IS CAST, LOOSEN TOP NUT ON STUD BOLT 3 TO PERMIT TEMPERATURE LINE MOVEMENT IN THE ASSEMBLY. ALTERNATE THE PATTERN BETWEEN NEAR SIDE AND FAR SIDE OF JOINT ON EC5 BARS SUCCESSIVE ASSEMBLIES, I.E. LOOSEN TOP NUT ON STUD BOLT 2 IMMEDIATELY AFTER BLOCKOUT IS EA6 BARS EA6 BARS 8. PROVIDE LOW FRICTION INTERFACE BETWEEN BOTTOM NUT AND WASHER ON STUD BOLTS AND ANGLE. EA6 BARS EACH FACE EA4 BARS TOP OF DRAIN TROUGH SLAB EACH FACE 2’-1" A6 BARS A6 BARS @ 12 CAST TO PERMIT MOVEMENT. EA6 BARS EACH FACE BRGS 9. AFTER THE CONCRETE OF THE BLOCKOUT ACHIEVES PRESCRIBED STRENGTH IN ACCORDANCE WITH PUB. 408 SECTION 1001.3(q)1, REMOVE THE TEMPORARY SUPPORT ASSEMBLY AND GRIND OFF TACK WELDS UNTIL SMOOTH. 10. APPLY TOUCH-UP PAINT. MIN CONSTRUCTION JOINT CONSTRUCTION JOINT A5 BARS A6 BARS A5 BARS A6 BARS @ 12 EACH FACE NOTES 2" CLR. 1. FOR NOTES, SEE SHEETS 1 AND 2. (TYP.) RF FF A5 BARS @ 6 LAP MIN. 2’-6" EACH FACE COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY F5 BARS @ 6 FF F5 BARS F5 BARS F5 BARS @ 6 RF STANDARD A’ BRIDGE APPROACH SLABS TYPE 4 - DRAIN TROUGH DETAILS 2 SECTION Q-Q SECTION A’-A’ RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 34 OF 35 BD-628M 5’-0" ADJACENT TO FLEXIBLE PAVEMENT (DETAIL 16), CONCRETE PAVEMENT (DETAIL 17) 1" FORMED OR NEOPRENE STRIP SEAL DAM ADJACENT TO FLEXIBLE PAVEMENT (DETAIL 13) EDGE OF APPROACH SLAB JOINT (TYP) DESCRIPTION OF DETAILS FOR 6’-0" ADJACENT TO PAVEMENT RELIEF JOINT (DETAIL 18) SEE DETAIL A 1" MIN. NOMINAL WIDTH 8’-6" NEOPRENE STRIP SEAL DAM ADJACENT TO PAVEMENT RELIEF JOINT (DETAIL 15) NEOPRENE COMPRESSION SEAL WINGWALL BARRIER 1" FLUSH CURB CURB BLOCK EXPANSION JOINT (ROADWAY ITEM) C (SEE NOTE 5) 3" B CURB 8" OUTSIDE FACE N N OUTSIDE FACE BARRIER WITH TRANSITION OF BARRIER TYPE 5 APPROACH SLAB 7’-6" NEOPRENE STRIP SEAL DAM ADJACENT TO CONCRETE PAVEMENT (DETAIL 14) OR 1" MIN. NOMINAL DETAIL WIDTH INVERTED V JOINT OF BARRIER SEAL FOR 1/2" MOVEMENT DESCRIPTION SHEET NO. END OF APPROACH SLAB WITH NEOPRENE STRIP 13 CLASSIFICATION, SEE NOTE 7. 22 SEAL DAM ADJACENT TO FLEXIBLE PAVEMENT END OF APPROACH SLAB WITH NEOPRENE STRIP 14 22 SEAL DAM ADJACENT TO CONCRETE PAVEMENT " 1" CLOSED CELL 0" ’10 N. 6) I M TE NO EE (S CELL NEOPRENE SPONGE (TYP.) ITEM) 15 22 SEAL DAM ADJACENT TO PAVEMENT RELIEF JOINT (PLACED CURB SHOULDER 8 INLET (ROADWAY 1" CLOSED END OF APPROACH SLAB WITH NEOPRENE STRIP APPROACH SLAB NEOPRENE SPONGE C B TO CURB) END OF APPROACH SLAB ADJACENT TO FLEXIBLE 16 23 PAVEMENT STRUCTURE BACKFILL, REFER TO RC-12M. END OF APPROACH SLAB ADJACENT TO CONCRETE 17 23 PAVEMENT SECTION B-B END OF APPROACH SLAB ADJACENT TO PAVEMENT 18 23 RELIEF JOINT #5 @ 12" OPTIONAL KEYED AB SL ER LS EP AI E T SL DE E SE CONSTRUCTION JOINT (SEE DETAIL B, SHEET 5) PAVEMENT APPROACH SLAB (ROADWAY ITEM) JOINT OPENING JOINT OPENING AS REQUIRED AS REQUIRED FOR NEOPRENE STRIP SEAL X AT GUTTER LINE 3-" DIA. GALVANIZED A325 BOLTS WITH GALVANIZED " " PLATE " WASHERS WITH THREADED 5 SEE DETAIL P " BETWEEN BOTTOM OF PLATE AND TOP OF SLEEPER SLAB SLEEPER SLAB INSERTS (TYP.) " REMOVABLE GALVANIZED STEEL PLATE SECTION Y-Y OPTIONAL KEYED " DIA. HOLES 3" NG VI PA H TC NO SIDE 3" AT GUTTER LINE P TO " T. 12 BO @ " #5 12 @ 7 # 6" SLAB SIDE 1" TOP OF APPROACH SLAB 5 X ROADWAY " SIDE TOP OF APPROACH SLAB 1’-5 SIDE APPROACH SLAB BRIDGE HIGHWAY APPROACH STRIP SEAL BRIDGE WIDTH 5" 25’-0" ROADWAY WIDTH C L CURB TO CURB WIDTH MATCH BRIDGE SKEW #10 @ 6" BOT. SKEW ANGLE TO #5 @ 12" SLEEPER SLAB NT ME UT AB #8 @ 12" TOP & BOT. APPROACH SLAB #5 @ 12" TOP FOR NEOPRENE (FOR NEOPRENE STRIP SEAL) 4" 4" CONSTRUCTION JOINT MIN. 5" NOTE: MIN. (SEE DETAIL B, SHEET 5) DESIGNER TO DETERMINE L LENGTH (L) OF PLATE. EDGE OF APPROACH SLAB SHOULDER PLATE AND OTHER ITEMS INCIDENTAL TO COST OF C 8" OF ABUTMENT CURB FRONT FACE NEOPRENE STRIP SEAL DAM. DETAIL P END COVER PLATE OUTSIDE FACE BOND END OF JOINT SEAL TO OF BARRIER INTERGRAL ABUTMENT (TYP). 8 1. FOR NOTES, SEE SHEETS 1 AND 2. B (SEAL ENDS OF NEOPRENE NOTES " Y BARRIER Y 3" B JOINT SEAL C GUTTER LINE ALONG GUTTER LINE SEE SECTION B-B PLAN AND NOTE 7 AND JOINT SEALING MATERIAL TYPE 5 5. PROVIDE TYPE 2-SC GUIDE RAIL WITH POSTS AT 3’-1" SPA. ALONG CURB AFTER APPROACH END TRANSITION. 6. INLET TO BE LOCATED SUCH THAT ITS OUTFLOW PIPE MISSES TYPE 2-SC POSTS IN GUIDE RAIL TRANSITION. APPR0ACH SLAB WITH INTEGRAL ABUTMENT PRIOR TO INSTALLATION ) 3. FOR SECTION N-N, SEE SHEET 21. 4. PROVIDE PAVING NOTCH FROM CURB TO CURB. 1" CLOSED CELL NEOPRENE SPONGE COMPRESSION SEAL PER DETAILS ON BC-766M, 2. FOR SECTION C-C, SEE SHEET 5. DETAIL A SET TO CURB TO CURB WIDTH WITH U-WINGS 7. USE ONLY APPROVED SEALS, AS LISTED IN BULLETIN 15. INSTALL JOINT SEALS TO A UNIFORM DEPTH WITH THE HIGHWAY TOP OF THE SEAL FROM 1/4" TO 1/2" BELOW THE SIDE LEVEL OF THE PAVEMENT SURFACE. MAKE THE TOP EDGES 25’-0" FOR INTEGRAL OF THE CONTACT SURFACES ON BOTH SIDES OF THE SEAL ABUTMENT DETAILS, 2’-9" AT THE SAME ELEVATION. SEE DETAILS " (TYP.) #5 @ 12" BRIDGE 2 SEE DETAIL O SIDE CLR. SEE BD-667M 13, 14, 15, 16, 17 AND 18 1’-6" 3" CLR. (TYP.) SAWCUT ** COMMONWEALTH OF PENNSYLVANIA " JOINT SEALING ROADWAY MATERIAL #10 @ 6" GRADE DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY " #7 @ 12" 3" (BOTH ENDS) CLR. #5 @ 12" PROVIDE 2 LAYERS OF 4 MIL. POLYETHYLENE SHEETING STRUCTURE BACKFILL, REFER TO RC-12M. UNDERNEATH APPROACH SLAB SLEEPER SLAB PAY LIMITS FOR BRIDGE APPROACH SLAB QUANTITIES SUBSURFACE DRAIN (ROADWAY ITEM)(REFER STANDARD " #6 @ 9" " TO 6" ** BRIDGE APPROACH SLABS TO INSTRUCTIONS TO DESIGNER NOTES) ** REFER TO BD-667M FOR INTEGRAL CONCRETE ADDITIONAL DETAILS ABUTMENT APPROACH SLAB TYPE 5 - PLAN AND SECTION COAT WITH BOND BREAKER PRIOR TO PLACING APPROACH SLAB CONCRETE SECTION X-X DETAIL O RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHEET 35 OF 35 BD-628M