1734sc-OE2CIH 2 Channel HART Protocol Analog Output Module for Allen-Bradley Point I/O • Two channels of isolated current and HART protocol output provide a flexible solution for process applications • 4 to 20mA current output, 16 bit resolution, 2/4 wire support • Auto-scanning of HART variables (PV,SV,TV,FV) • HART Modem per channel • HART Pass-Through Messaging • Open circuit detection • Fault reporting • 24V Fault Protection • Removal and insertion under power (RIUP) • DTM and CONNECTS support allowing interface to your asset management software Reduce System Costs The 1734sc-OE2CIH module maximizes your system performance by combining real-time HART data acquisition in conjunction with standard analog acquisition and control—at a fraction of the cost. Simplify commissioning, operation and maintenance. The data may be used as the foundation for your asset management system. State-of-the-Art Features The 1734sc-OE2CIH Analog Output Module provides remote I/O with full analog capability and the benefit of HART (highway addressable remote transducer) protocol in an I/O module. The module offers two channels of isolated analog output, each easily configured for current or current plus HART signals. The 1734sc-OE2CIH also acts as a HART master, allowing communication with HART field devices. HART data is available directly on the Point I/O network. The Spectrum Controls 1734sc-OE2CIH is compatible with Allen-Bradley Point I/O (EtherNet and ControlNet) communication adapters. It offers the functionality of dedicated analog output modules without compromising performance or price. Spectrum Controls, Inc. • P.O. Box 6489 • Bellevue, Washington 98008 USA • Tel: (425) 746-9481 • Fax: (425) 641-9473 Web Site: www.spectrumcontrols.com • E-mail: spectrum@spectrumcontrols.com 1734sc-OE2CIH 2 Channel HART + Analog Output Module for Allen-Bradley Point I/O Number of outputs Two isolated outputs Output ranges 0-20mA & 4-20mA (HART only available on 4-20 range) Output load 0-750Ω max, 200-750Ω for HART Resolution 16 bits across 21mA => 320nA Update time (minimum) 10ms analog / 6 seconds HART HART Dynamic Variables PV, SV, TV, FV Full scale settling time <100ms to 95% with resistive loads Differential nonlinearity +/- 0.05% full scale Output ripple +/- 0.05% or better full scale 0-50kHz Repeatability (HART disabled) +/- 0.05% full scale Max inductive load 10uH Output impedance >10kΩ at 1kHz, >1k at 10kHz Accuracy Long term drift Range Temperature Accuracy (% full scale) 0-21mA extended 25ºC 0.15% FS 0-21mA extended -20ºC - 55ºC 0.3% FS target Open & short circuit protection Yes, continuous. (IEC 1131-2 requirement) Isolation voltage 50V (continuous) channel to backplane and between channels SV pointbus current 55mA External DC power Supply voltage 24VDC nominal - 10VDC-28.8VDC (voltage range) Field supply current draw with 20mA into 750Ω loads 175mA @ 12VDC max - 77 mA @ 24VDC typ Power dissipation 1.5W max (1.25W typical) Storage temperature -45C - +85C (5% - 95% non-condensing humidity) Key switch position 4th position Terminal base 1734-TB Wire size Determined by installed terminal block Data format Signed integer Maximum input’s overload Fault protected to +/- 24VDC Calibration Factory-only calibration supported, no user calibration Corporate Headquarters Spectrum Controls, Inc. P.O. Box 6489 • Bellevue, WA 98008 USA Tel 425-746-9481 • Fax 425-641-9473 Email spectrum@spectrumcontrols.com www.spectrumcontrols.com ©2014, Spectrum Controls, Inc. All rights reserved. All other trademarks are the property of their respective owners. Specifications subject to change without notice. Printed in USA. Publication 0100111-01 Rev A 1/14