www.mgeups.com MGE UPS SYSTEMS, INC. S4 3.5kVA-21kVA Scalable N+1 Inverter Advanced Features ◗ Constructed to NEBS /Telecom industry standards ◗ True Modular Scalability: 3.5 kVA-21 kVA (3.5 kVA modules) – add modules as your system grows ◗ Parallel for N+1 redundancy or capacity ◗ Safe hot swap technology ◗ Unparalleled reliability: no single points of failure ◗ Full front accessibility ◗ Ultra low profile: 21 kVA in 24 U with static switch The Next Generation in AC Telecom Power MGE’s Power-Invert™ S4 N+1 scalable DC to AC inverter is the latest addition to the ◗ Clean DC input < 30 dBrnc Power-Invert™ line recognized as the industry standard for critical AC power by many ◗ Precision output voltage regulation: + 1% THD of the world’s leading telecom companies. The S4’s scalable 3.5 kVA inverter power modules can be stacked in a N+1 redundant configuration for optimum reliability up to 21 kVA. This modular scalability makes the Power-Invert™ S4 ideal for overlay ◗ Integrated static bypass for added reliability applications where future power growth is anticipated. All modules are packaged into a “hot swap” receiver cabinet allowing rapid and safe exchange of any component without interruption to the critical load. ◗ Universal voltage and frequencies (user selectable) S4 “Fortress” Topology ~ High Reliability Features Redundant Microcontroller Modules If the primary micro controller module is ever compromised, the secondary module continues to provide uninterrupted performance. Digital Calibration & Self Diagnostics Any drift in settings is immediately self corrected, eliminating maintenance and calibration requirements. Redundant 3.5 kVA “hot swappable” Inverter Modules Permits power modules to go off line and be quickly replaced while keeping the load on inverter power. Integrated Electronic Static T H E Transfer Switch Provides six sigma reliability by adding a third layer of protection by rapidly and seamlessly transferring to bypass power if required. Rack mount receiver cabinet with rapid change connector system Swap components on-line safely and rapidly with no wiring connections and without risking system perfomance. U N I N T E R R U P T I B L E P O W E R ◗ LCD status display module P R O V I D E R ◗ Customers supported by MGE’s Trained and Certified Field Engineer force ◗ International agency certifications (UL, CE, TUV) Power-Invert™ S4 Inverter Plant Accessories Options to meet specific requirements Why is the S4 theyour most reliable critical power protection solution? System Operation: Tri-Layer Redundancy: The Inverter plant receives 48 VDC from a DC power plant/battery bank and converts the output to precision regulated AC power (user selectable voltage and frequency). In the event that the DC is not available or out of tolerance due to a discharged battery, or the inverters are not able to maintain the critical load, the system will automatically transfer via the static transfer switch and disconnect from the DC source. The static transfer switch (standard) will make a seamless, uninterrupted transfer from the critical load to an alternate AC power source where the inverter power was synchronized to utility power or another protected AC source. The MTBF of the S4 N+1 on-line mode with a backup source present is greater than 99.9999%. Three independent layers of redundancy contribute to the S4’s reliability starting with the N+1 inverter assemblies, dual independent microcontrollers and integrated static transfer switch for a final layer of protection. CONTROLLER(S) INVERTER INVERTER DC INPUT INVERTER AC INPUT STATIC SWITCH Telecom Grade Filtering: Since the S4 is connected to large telecom battery plants and shared by other critical equipment, it is equipped with a high grade noise filter system, limiting ripple current on the battery to well under required levels, as well as ensuring that radiated and conducted EMI are kept to safe levels. AC OUTPUT DC POWER N+1 REDUNDANT INVERTER ASSEMBLIES REDUNDANT AC BYPASS SOURCE Tri Layer Redundancy DUAL REDUNDANT MICROCONTROLLERS N+1 REDUNDANT INVERTER ASSEMBLIES REDUNDANT AC BYPASS SOURCE (Static Switch) Regulatory Compliance ~ built to meet industry standards The S4 inverter is designed to meet the stringent regulatory qualifications demanded by telecommunications facilities. As well as meeting all major safety standards, the S4 inverter is one of the only inverters designed to meet Network Equipment Building System (NEBS) standards~ the industry benchmark for product quality and reliability. ◗ ◗ ◗ ◗ NEBS CE UL TUV S4 Power Center: The six 9s solution for ultra critical IT installations The S4 Power Center provides up to a 21 kVA N+1 power system S4 Power Center Components complete with maintenance bypass and distribution in one 70" The S4 Power Center can also integrate a DC power source (rectifier high rack enclosure. The scalability, redundancy and rack mounted and battery bank) transforming the system into a complete double configuration of the S4 makes it an ideal solution for mid range conversion UPS system. IT applications that require a very high level of reliability. Receiver Cabinets Part Number* 64074-94 MGE 7 kVA receiver assembly w/STS (no inverters) 64144-94 MGE 14 kVA receiver assembly w/STS (no inverters) 64214-94 MGE 21 kVA receiver assembly w/STS (no inverters) 64144-94J MGE 14 kVA receiver assembly w/STS (no inverters) with Junction Box 64214-94J MGE 21 kVA receiver assembly w/STS (no inverters) with Junction Box * NOTE: For Line to Line (208/240V) version, add an “H” on the end of the part number. Power-Invert™ S4 Inverter Plant Accessories Options to meet your specific requirements The S4 is available with the following optional accessories, all of which can be factory installed on an open frame relay rack, providing a ready to install inverter system. Maintenance Bypass: AC Distribution Panel Safely and seamlessly transfers the output to an alternate AC source (utility power or protected AC power from another inverter or UPS system) allowing the inverter to be shutdown or removed without interrupting power to the critical loads. The Maintenance Bypass assembly is factory wired to the inverter module when ordered as a system. AC Distribution Panel: The AC distribution panel accommodates 20 single pole breakers and is available in 120 and 240 VAC versions. 10 x two pole breakers can be used if distribution alarm monitoring is required. Maintenance Bypass Cabinet Web Based Monitoring: The Falcon monitoring system (1.75” high rack mounted) provides inverter, maintenance bypass and AC distribution status and alarms over a closed network or via the Internet serving up web pages that can be viewed with a standard browser or via SNMP or dial up access. Accessories include environmental monitoring modules and auxiliary inputs to monitor other devices such as leak detection systems, room security or any other dry contact status points. S4 Fortress Inverters Open Frame Relay Rack: All components can be mounted on an industry standard open frame relay rack with the entire inverter plant certified for zone 4 seismic installations. Conduit Junction Boxes: (optional when maintenance bypass is not used) Larger inverter modules such as the 14 kVA through 21 kVA require substantial cable gauges. The conduit junction box is factory mounted to the back of the inverter module, easing conduit landing requirements and simplifying installation of rear mounted cable entry systems. Rack Inverter Systems Inverter systems include inverter(s), receiver cabinet, static switch and single controller module (redundant controller module optional). N+1 redundant power rating indicates that a single inverter module can go off-line with existing inverters maintaining the critical load. (Rack mount bracket kit is optional.) Part Number * With Junction Box System Output Power (kVA) 3.5 Qty. Inverters Supplied (x 3.5 kVA) 1 Total # of Bays (x 3.5 kVA) 2 Receiver Cabinet Capacity (kVA) 7.0 64074-9401 N/A 64074-9402 N/A 7.0 2 2 7.0 64144-9402 64144-9403 64144-94J2 7.0 2 4 14.0 64144-94J3 10.5 3 4 14.0 64214-9403 64214-94J3 10.5 3 6 21.0 64144-9404 64144-94J4 14.0 4 4 14.0 64214-9404 64214-94J4 14.0 4 6 21.0 64214-9405 64214-94J5 17.5 5 6 21.0 64214-9406 64214-94J6 21.0 6 6 21.0 Junction Box - Suggested on 14 kVA (6414J) & 21 kVA (6421J) Receivers when Maintenance Bypass Not Used - Adder * NOTE: For Line to Line (208/240V) version, add an “H” on the end of the part number. Power-Invert™ S4 Technical Specifications The Power-Invert™ S4 Input Voltage -48VDC (40-57 VDC) Output/Bypass Voltage line to neutral 110, 115, 120, 220, 230, 240 (user selectable) Output/Bypass Voltage line to line 208, 220, 230, 240 (user selectable) Output Frequency User-selectable 50Hz or 60Hz (+/-0.02%) Output Waveform High resolution PWM sine wave Inverter Technology IGBT PWM Load/Line Voltage Regulation < +/- 1% Static Switch Transfer Time < than 3 ms Efficiency 88% typical (on-line mode) to 97% typical (off-line eco mode) Transient Response 5% deviation with 1millisecond recovery from zero to full load Overload Capability 106% of continuous rated VA/watts at 20°C. Short Circuit Current (SCC) 300% for more than 4 cycles Audible Noise Less than 60 dBA EMI Emission (DC Ripple) <30 dBrnc. Total Harmonic Distortion < 1% for linear loads, <3% for crest factor loads up to 3:1. Monitoring LCD with true RMS metering and LED status display, dry contacts Calibration Digitally controlled / automatic Operating Temperature Operating Humidity Operating Altitude Agency Approvals Design Mandate Before designing the S4, MGE’s team of engineers was given the following non-compromising instructions: Reliability: Eliminate single points of failure and allow component changes without interrupting the load. Scalability: Allow users to add extra power for increased capacity as well as redundancy. Maintainability: Ensure that all components can be exchanged safely and rapidly by any technician. Installability: Minimize the mechanical profile of the system while eliminating any requirement for rear access. Operability: Provide clean, comprehensive operating status information with robust communication interfaces. 0 to +55° C (-40° C to +75° C shipping) 0 to 90% relative, without condensation. <10,000 without de-rating UL/CSA 60950 (listed) and European Standard EN60950, CE, TUV, FCC class A certified 19, 23, 25" rack or floor mounted RAL 902 off white I year Installation Finish Warranty Power-Invert™ S4 Selection Guide [1] Select line to neutral or line to line voltage model [2] Select a receiver cabinet (7, 14 or 21 kVA); determines minimum and maximum kVA of the system. [3] Select the quantity of 3.5 kVA inverter modules. Ensure that the total inverter output is at least 3.5 kVA greater than the load for N+1 redundancy Maintenance Bypass (optional) [4] For 14 kVA or 21 kVA receiver cabinets without a maintenance bypass, select a rear mounted conduit option box for sufficient cable landing space. AC Bypass input DC input [5] Inverter systems ordered with optional Maintenance Bypass Module and/or AC Distribution Panel and Telecom Rack are pre-wired to inverter. AC Distribution Panel (optional) Static Transfer Switch Inverter Modules (1-6 modules) 3.5 kVA Inverter [6] Rack mounting bracket options are available for 19", 23", 25" and 26" racks. EMI Filter Static Transfer Switch Assembly Power-Invert™ S4 Options 3.5 kVA Inverter ◗ ◗ ◗ ◗ ◗ ◗ ◗ Dry Contact Alarms 3.5 kVA Inverter RS232 Comm. Port * requires external hardware * 3.5 kVA Inverter Power-Invert™ S4 3.5 kVA Inverter System Schematic 3.5 kVA Inverter System Height 17.0” W x 18.5” D Receiver Cabinet Capacity kVA 21.0” 7.0 (min/max inverter qty 1-2) 31.5” 14.0 (min/max inverter qty 2-4) 42.0” 21.0 kVA Qty. Inverters Power kVA / kW 3.5 7.0 1 2 3.5/3.0 7.0/6.0 88 176 26 52 10.5 3 10.5/9.0 265 14.0 4 14.0/12.0 17.5 5 6 Inverter Capacity 23" Open Frame Relay Rack Web Enabled Status Monitor AC Distribution Panel w/ Alarm Indication - 20 pole/24 pole Maintenance Bypass (rack mounted) Rack Mount Kits (19", 23", 25", 26" versions) On Site Start-Up and Commissioning On Site Service Plans & Extended Warranty Max BTU (A) suggested 135 182 1807 3614 200 200 80 80 40 40 78 252 5421 400 150 80 353 104 299 7227 400 150 80 17.5/15.0 441 130 371 9034 600 225 125 21.0/18.0 529 157 418 10,841 600 225 125 DC Input Output (A) Approx. System (A) Max. @120VAC* Weight(lbs) * DC Breaker AC Input Breaker AC Input Breaker (A) @ 120 VAC (A) @ 240VAC (min/max inverter qty 3-6) 21.0 * Inverters and receiver cabinet shipped separately. Each inverter is approx. 47 lbs. MGE UPS SYSTEMS, INC. USA (headquarters) 1660 Scenic Avenue Costa Mesa, CA 92626 tel (800) 523-0142 (714) 557-1636 fax (714) 557-9788 T H E CANADA #9, 2798 Thamesgate Dr. Mississauga, ON L4T 4E8 tel (905) 672-0990 (877) 672-0990 fax (905) 672-7667 ARGENTINA Avenida Uzal 3556 (1636) Olivos, Pcia. de Buenos Aires, Rep. Argentina tel (54) 11-4766-8777 fax (54) 11-4766-6008 ©MGE UPS SYSTEMS, Inc. All specifications subject to change without notice. The MGE UPS SYSTEMS logo is a trademark of MGE UPS SYSTEMS. U N I N T E R R U P T I B L E BRAZIL • Sao Paulo Office: Avenida Guido Caloi 1985 (Galpao 23), Guarapiranga Sao Paulo –SP, 05802-140Brazil tel (55) 11-5515-9255 fax (55) 11-5515-9250 P O W E R MEXICO Ave. Congreso de la Union #524 Colonia Santa Anita Mexico D.F 08300 tel 525 538 9687 fax 525 530 7625 P R O V I D E R www.mgeups.com info@mgeups.com Pwrinvrt S4 Revision 100 Effective: October 2005