Current Transducer LA 55-P IPN = 50 A For the electronic measurement of currents : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Electrical data IPN IP RM Primary nominal r.m.s. current Primary current, measuring range Measuring resistance @ with ± 12 V with ± 15 V ISN KN VC IC Vd 50 0 .. ± 70 TA = 70°C TA = 85°C RM min RM max RM min RM max @ ± 50 A max @ ± 70 A max @ ± 50 A max @ ± 70 A max 10 10 50 50 Secondary nominal r.m.s. current Conversion ratio Supply voltage (± 5 %) Current consumption R.m.s. voltage for AC isolation test, 50 Hz, 1 mn 100 50 160 90 60 95 60 1) 60 1) 135 155 135 2) 135 2) A A ε Accuracy @ IPN , TA = 25°C @ ± 15 V (± 5 %) @ ± 12 .. 15 V (± 5 %) Ω Ω Ω Ω 50 mA 1 : 1000 ± 12 .. 15 V 10 (@ ± 15 V) + IS mA 2.5 kV Linearity L ± 0.65 ± 0.90 < 0.15 Typ IO IOM IOT tra tr di/dt f % % % Max ± 0.2 ± 0.3 ± 0.5 ± 0.6 Offset current @ IP = 0, TA = 25°C Residual current 3) @ IP = 0, after an overload of 3 x I PN Thermal drift of IO 0°C .. + 70°C - 25°C .. + 85°C ± 0.1 ± 0.1 Reaction time @ 10 % of IP max Response time @ 90 % of IP max di/dt accurately followed Frequency bandwidth (- 1 dB) < 500 <1 > 200 DC .. 200 •Closed loop (compensated) current transducer using the Hall effect Accuracy - Dynamic performance data X Features mA mA mA mA ns µs A/µs kHz •Printed circuit board mounting •Insulated plastic case recognized according to UL 94-V0. Advantages •Excellent accuracy •Very good linearity •Low temperature drift •Optimized response time •Wide frequency bandwidth •No insertion losses •High immunity to external interference •Current overload capability. Applications •AC variable speed drives and servo motor drives •Static converters for DC motor drives •Battery supplied applications •Uninterruptible Power Supplies (UPS) •Switched Mode Power Supplies (SMPS) •Power supplies for welding General data TA TS RS Ambient operating temperature Ambient storage temperature Secondary coil resistance @ m Mass Standards Notes : 1) 2) 3) 4) TA = 70°C TA = 85°C 4) Measuring range limited to ± 60 A max Measuring range limited to ± 55 A max Result of the coercive field of the magnetic circuit A list of corresponding tests is available LEM Components - 25 .. + 85 - 40 .. + 90 80 85 18 EN 50178 °C °C Ω Ω g applications. 980706/8 w w w .lem.com Dimensions LA 55-P (in mm. 1 mm = 0.0394 inch) Bottom view Left view Secondary terminals swiss made Terminal + : supply voltage + 12 .. 15 V Terminal - : supply voltage - 12 .. 15 V Terminal M : measure Connection Standard 00 or N° SP.. Year Week Front view Mechanical characteristics •General tolerance •Primary through-hole •Fastening & connection of secondary Recommended PCB hole Remarks ± 0.2 mm 12.7 x 7 mm 3 pins 0.63 x 0.56mm 0.9 mm •IS is positive when IP flows in the direction of the arrow. •Temperature of the primary conductor should not exceed 90°C. •Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole. •In order to achieve the best magnetic coupling, the primary windings have to be wound over the top edge of the device. •This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...), please contact us. LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice. This datasheet has been downloaded from: www.DatasheetCatalog.com Datasheets for electronic components.