Current Transducer LAC 300

advertisement
IPN
Current Transducer LAC 300-S/SP2
=
300 A
For the electronic measurement of currents: DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
Electrical data
IPN
IP
IPM
Primary nominal current rms
Primary current < 500 ms
Primary current, measuring range
RM
Measuring resistance
with ± 15 V
ISN
KN
VC
IC
@ ± 640 A maxi
Secondary nominal current rms
Conversion ratio
Supply voltage (± 5 %)
Current consumption
300
500
0 .. ± 640
@ TA = 85°C
RM mini RM maxi
A
A
A
0
Ω
10
100
1 : 3000
± 15
25 + IS
XG
Overall accuracy @ IPN , TA = 25°C
Linearity error
L
±1
< 0.1
IO
IOM
IOT
Typ Maxi
Offset current @ IP = 0, TA = 25°C
± 0.15
Magnetic offset current @ IP = 0, after an overload of 3 x IPN
± 0.15
Temperature variation of IO
- 40°C .. + 85°C
± 0.2 ± 0.50
tr
di/dt
BW
Response time @ 90 % of IPN step
di/dt accurately followed
Frequency bandwidth (- 3 dB)
<1
> 50
DC .. 50
mA
V
mA
%
%
mA
mA
mA
µs
A/µs
kHz
General data
TA
TS
RS
m
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @ TA = 85°C
Mass
Standards
• Closed loop (compensated) current
transducer using the Hall effect
Accuracy - Dynamic performance data
ε
Features
- 40 .. + 85
°C
- 45 .. + 90
°C
53
Ω
137
g
EN 50155: 2001
• Isolated plastic case recognized
according to UL 94-V0.
Special features
•
•
•
•
IPN
IP
IPM
KN
=
=
=
=
300 A
500 A (< 400 ms)
0 .. ± 640 A
1 : 3000.
Advantages
•
•
•
•
•
•
•
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
• Current overload capability.
Applications
•
•
•
•
•
Single or three phases inverter
Propulsion and braking chopper
Propulsion converter
Auxiliary converter
Battery charger.
Application Domain
• Traction.
Page 1/3
070724/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com
Current Transducer LAC 300-S/SP2
Isolation characteristics
Vd
Rms voltage for AC isolation test, 50 Hz, 1 min
5.5
kV
dCp
dCl
CTI
Creepage distance
Clearance distance
Comparative Tracking Index (Group I)
Mini
21.2
11.2
600
mm
mm
Safety
This transducer must be used in electric/electronic equipment with respect to
applicable standards and safety requirements in accordance with the following
manufacturer's operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a built-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
070724/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com
Dimensions LAC 300-S/SP2
(in mm. 1 mm = 0.0394 inch)
Front view
Left view
Connection
Top view
Mechanical characteristics
Remarks
• General tolerance
• Transducer fastening
• IS is positive when IP flows in the direction of the arrow.
• Temperature of the primary conductor should not exceed
± 0.5 mm
4 holes ∅ 4.5 mm
4 M4 steel screws
Recommended fastening torque 2.90 Nm or 2.15 Lb - Ft.
Or
4 slots ∅ 4.5 mm
4 M4 steel screws
Recommended fastening torque 2.90 Nm or 2.15 Lb - Ft.
• Primary through-hole
13 x 30 mm
• Connection of secondary
Molex serie 70543-0003
100°C.
• Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
Page 3/3
070724/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
w w w .lem.com