Voltage Transducer LV 100-4000/SP12 VPN = 4000 V

advertisement
Voltage Transducer LV 100-4000/SP12
For the electronic measurement of voltages: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
Features
Electrical data
VPN
VPM
IPN
R M
Primary nominal voltage rms
Primary voltage, measuring range
Primary nominal current rms
Measuring resistance
with ± 15 V
with ± 24 V
ISN
K N
VC
IC
@ ± 4000 V max
@ ± 6000 V max
@ ± 4000 V max
@ ± 6000 V max
Secondary nominal current rms
Conversion ratio
Supply voltage (± 5 %)
Current consumption 4000
0 .. ± 6000
2.5
RM min RM max
0
0
0
110
210
120
410
250
V
V
mA
Ω
Ω
Ω
Ω
50
mA
4000 V : 50 mA
± 15 .. 24
V
< 37 (@ ± 24V) + ISmA
Accuracy - Dynamic performance data
XG
εL
IO
IOT
Overall accuracy @ VPN, TA = 25°C
± 0.9
Linearity error
< 0.1
Typ Max
Offset current @ IP = 0, TA = 25°C
± 0.2
Temperature variation of IO
- 25°C .. + 85°C ± 0.4 ± 0.8
tr
Response time to 90 % of VPN step
%
%
mA
mA
200
µs
- 25 .. + 85
- 45 .. + 95
40000 : 2000
10
1.6
57
790
EN 50155: 1995
°C
°C
General data
TA
TS
NP
P
R 1
RS
m
VPN= 4000 V
Ambient operating temperature
Ambient storage temperature
Turns ratio
Total primary power loss
Primary resistance @ TA = 25°C
Secondary coil resistance @ TA = 85°C
Mass
Standards W
MΩ
Ω
g
●● Closed loop (compensated)
voltage transducer using Hall
effect
●● Isolated plastic case recognized
according to UL 94-V0
●● Primary resistor R1 incorporated
within the housing.
Special features
●● VC = ± 15 .. 24 V (± 5 %) V
●● TA = - 25°C .. + 85°C
●● Connection to primary circuit by
extra-long studs
●● Shield between primary and
secondary
●● Connection to primary and
secondary circuit on M5 threaded
studs.
Advantages
●●
●●
●●
●●
●●
●●
●●
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference.
Applications
●●
●●
●●
●●
●●
Single or three phase inverter
Propulsion and braking chopper
Propulsion converter
Auxiliary converter
Battery charger.
Application Domain
●● Traction.
Page 1/3
110308/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Voltage Transducer LV 100-4000/SP12
Isolation characteristics
Vd
dCp
dCI
CTI
Rms voltage for AC isolation test, 50 Hz, 1 min
Creepage distance
Clearance distance
Comparative Tracking Index (group I)
12 1)
1 2)
Min
164.8
47.1
600
kV
kV
mm
mm
Notes: 1) Between primary and secondary + shield + heatsink
2)
Between secondary and shield.
Safety
This transducer must be used in electric/electronic equipment with respect
to applicable standards and safety requirements in accordance with the
manufacturer’s operating instructions.
Caution, risk of electrical shock
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.
Page 2/3
110308/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com
Dimensions LV 100-4000/SP12 (in mm)
Connection
Mechanical characteristics
●● General tolerance
●● Transducer fastening
Recommended fastening torque
●● Connection of primary
●● Connection of secondary
●● Connection of ground
Recommended fastening torque
Remarks
± 0.3 mm
2 holes Ø 6.5 mm,
2 M6 steel screws
5 Nm
M5 threaded studs
M5 threaded studs
M5 threaded stud
2.2 Nm
●● IS is positive when VP is applied on terminal +HT.
●● The primary circuit of the transducer must be linked to the
connections where the voltage has to be measured.
Page 3/3
110308/3
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice