© Siemens AG 2008 PAC3200 Multifunction Measuring Instruments and Expansion Modules Catalog News LV 1 N • June 2008 SENTRON © Siemens AG 2008 Related catalogs Contents Low-Voltage Controls and Distribution SIRIUS · SENTRON · SIVACON Order No.: Catalog E86060-K1002-A101-A7-7600 Technical Information incl. Systems Controlgear: Contactors and contactor assemblies, solid-state switching devices Protection equipment Load feeders, motor starters and soft starters Monitoring and control devices Detecting devices Commanding and signaling devices Transformers Power supplies Planning and configuration with SIRIUS Power Management System SIVACON Power, distribution boards, busway and cubicle systems SENTRON switching and protection devices for power distribution Air circuit breakers, molded case circuit-breakers, switch disconnectors Software for power distribution BETA lowvoltage circuit protection Low-Voltage Controls and Components for Applications according to UL Order no.: E86060-K1816-A101-A1-7600 Industrial Communication Industrial Communication for Automation and Drives Order No.: E86060-K6710-A101-B5-7600 E86060-K6710-A121-A2-7600 SICUBE System Cubicles and Cubicle Air-Conditioning · LV 1 LV 1 T LV 16 · · · · · · · · · · · · · · · SIRIUS 3RV17 and 3RV18 circuit breaker according to UL 489 SIVACON Components for 8US Distribution Systems according to UL 508A SENTRON 3WL5 air circuit breakers/non-automatic air circuit breakers according to UL 489/IEC SENTRON 3VL Molded Case Circuit Breakers according to UL 489/IEC ALPHA Devices according to UL Standard BETA Devices according to UL standard · · · · · PROFINET/Industrial Ethernet Industrial Mobile Communicaton PROFIBUS to IEC 61158/EN 50170 SIMATIC ET 200 distributed I/Os AS-Interface to EN 50295/IEC 61158 Remote operation with SINAUT Telecontrol Routers ECOFAST system · IK PI IK PI N LV 50 Order No.: · · · · · · · · System cubicles Cubicle modifications Cubicle expansion components Accessories Special cubicles Cubicle solutions in applications Cubicle air-conditioning Special colors · · · E86060-K1920-A101-A3-7600 · SIDAC Reactors and Filters Order No.: E86060-K2803-A101-A4-7600 LV 60 Commutating reactors for converters Mains reactors for frequency converters Iron-core output reactors Ferrite output reactors Iron-core smoothing reactors Smoothing air-core reactors Filter reactors Application-specific reactors Radio interference suppression filters dv/dt filters Sinewave filters SIVACON 8PS CD-K, BD01, BD2 Busbar Trunking Systems up to 1250 A Order No.: E86060-K1870-A101-A3-7600 LV 70 Busbar trunking systems, overview CD-K system (25 A to 40 A) BD01 system (40 A to 160 A) BD2 system (160 A to 1250 A) Automation & Drives The A&D Offline Mall CD-ROM: E86060-D4001-A110-C6-7600 DVD: E86060-D4001-A510-C6-7600 CA 01 All Automation and Drives products, including those in the catalogs listed above. · · ·· · · · · · · · A&D Mall Internet: http://www.siemens.com/ automation/mall All Automation and Drives products, including those in the catalogs listed above. Catalog-PDF Internet: http://www.automation. siemens.com/cd All catalogs for low-voltage controls and distribution can be downloaded as PDF files. Registered trademarks Technical Assistance All product designations may be registered trademarks or product names of Siemens AG or other supplying companies. Third parties using these trademarks or product names for their own purposes may infringe upon the rights of the trademark owners. Further information about low-voltage controls is available on the Internet at: http://www.siemens.com/lowvoltage · Expert technical assistance for Low-voltage controls and electrical installation. Tel.: +49 (9 11) 8 95-59 00 Fax: +49 (9 11) 8 95-59 07 E-Mail: technicalassistance@siemens.com © Siemens AG 2008 SENTRON PAC3200 Multifunction Measuring Instruments Catalog News LV 1 N · 06/2008 The products and systems listed in this catalog are manufactured/distributed using a certified quality management system which complies with EN ISO 9001 (for the Certificate Register No. see the Appendix of Catalog LV 1 · 2008). The certificate is recognized in all IQ Net countries. The corresponding section in Catalog News LV 1 N, which was in circulation up to 04/2008, is replaced by this Catalog News. Contact your local Siemens representative for further information © Siemens AG 2008 © Siemens AG 2008 PG 041, 101, 121, 230, 250, 540 ... PG 041, 101, 121 3RT, 3TB, 3TF Contactors for Switching Motors 3RA13, 3RA14, 3TD, 3TE Contactor Assemblies 3RT, 3RH, 3TB, 3TC, 3TH, 3TK Contactors for Special Applications 3RH, 3TH Contactor Relays · 3RT Coupling Relays 3TX7, 3RS18 Coupling Relays · LZS, LZX Plug-In Relays 3TG10 Power Relays/Miniature Contactors 6 Load Feeders, Motor Starters and Soft Starters 7 Monitoring and Control Devices 8 Detecting Devices 9 Commanding and Signaling Devices 10 3RV Motor Starter Protectors up to 100 A 3RV Molded Case Motor Starter Protectors up to 800 A 3RB2 Solid-State Overload Relays 3RU1 Thermal Overload Relays 3RW Soft Starters · 3RA Fuseless Load Feeders 3RA6 Fuseless Compact Load Feeders 3RA71 Load Feeders with Safety Integrated AS-Interface Motor Starters and Soft Starters ET 200S, ET 200pro Motor Starters ET 200S Safety Motor Starter Solutions Local / PROFIsafe ECOFAST Motor Starters and Soft Starters 3RE Encapsulated Starters SIMOCODE 3UF Motor Management and Control Devices LOGO! Logic Modules · 3RP, 3RT19 Timing Relays 3UG Monitoring Relays for Electrical and Additional Measurements 3RS10, 3RS11 Temperature Monitoring Relays 3RN1 Thermistor Motor Protection 3TK28 Safety Relays 3RS17 Interface Converters 3RK3 Modular Safety System 3SE2, 3SE3, 3SE5, 3SF1 Position Switches 3SF1 Hinge Switches 3SE6 Magnetically Operated Switches 3SB2, 3SB3, 3SF5 Pushbutton Units and Indicator Lights 3SE7, 3SF2 Cable-Operated Switches 3SE2, 3SE3 Foot Switches 8WD4 Signaling Columns 8WD5 Integrated Signal Lamps Transformers Single-Phase Transformers Three-Phase Transformers S8, 8PV For and resistive 8PT Power loads: Distribution Boards and Motor Control Centers 8PS Busbar Systems · 8MC, 8MF Cubicle Systems 3RF20,Trunking 3RF21, 3RF22 Solid-State Relays 8MR,3RF23, 8ME Cubicle 3RF24Air-Conditioning Solid-State Contactors · 3RF29 Function Modules ALPHA 630 - DIN Floor-Mounted Distribution Boards ALPHA Terminal Blocks ForFIX switching motors: ALPHA 8HP Solid-State Molded-Plastic Distribution 3RF24 Contactors and Systems Solid-State Reversing ContacComponents for 8US, 8UC, 4NC Distribution Systems tors Protection Switching Equipment and Protection Devices 15 5SENTRON for Power Distribution 3RV Molded Case Motor Starter Protectors up to 800 A 3RB2 Solid-State Overload Relays 3WL Air Circuit Breakers 3RU1 Thermal Overload Relays Load Feeders, Switching Motor andStarters Protection andDevices Soft Starters 16 6SENTRON for Power Distribution 3RW Soft Starters 3RA Fuseless Load Circuit Feeders 3VL, 3VF2 Molded Case Breakers 3RA71 Load Feeders with Safety Integrated AS-Interface Motor Starters and Soft Starters ET 200S, ET 200pro Motor Starters ET 200S Safety Motor Starter Solutions Local / PROFIsafe ECOFAST Motor Starters and Soft Starters 3RE Encapsulated Starters Monitoring Switching and Control and Protection Devices Devices 17 7SENTRON for Power Distribution SIMOCODE 3UF Motor Management and Control Devices Logic Modules · 3RP, 3RT19 Timing Relays 3KA, LOGO! 3KE, 3LD Switch Disconnectors 3UG Monitoring Relays for Electrical Additional Measurements 3KL, 3KM, 3NJ6 Switch Disconnectors withand Fuses 3RS11 Temperature Monitoring Relays 3NP, 3RS10, 3NJ4, 3NJ5 Fuse Switch Disconnectors 3RN1 Thermistor Motor Protection 3TK28 Safety Relays 3RS17 Interface Converters Detecting for Power Devices Distribution 18 8Software Dimensioning 3SE2, 3SE3, with SIMARIS 3SE5, 3SF1 design Position Switches Configuring, 3SF1 Hinge Visualizing Switches and Controlling with SIMATIC Configuring, 3SE6 Magnetically Visualizing and Operated Controlling Switches with SENTRON Commanding Low-Voltage and Circuit Signaling Protection Devices 19 9BETA Miniature 3SB2, Circuit 3SB3, Breakers 3SF5 Pushbutton (MCBs) Units and Indicator Lights Residual 3SE7, Current 3SF2Protective Cable-Operated Devices Switches Low-Voltage 3SE2, 3SE3 Fuse Foot Systems Switches SITOR 8WD Semiconductor Signaling Columns4 Fuses SR 608WD5 Busbar Integrated SystemsSignal Lamps Overvoltage Protection Devices Socket Outlets Measuring Devices Transformers 2010Appendix Glossary Single-Phase · Training Transformers · Ordering notes · Further documentation · Standards Three-Phase and approvals Transformers · Quality management · Siemens contacts · External partners · Online services · Customer support · Software licenses · Subject index Order number index including metal surcharges and export markings · Terms and Conditions of Sale and Delivery Low-Voltage Power Distribution Protection Equipment Low-Voltage Power Distribution SIRIUS Industrial Controls SIRIUS Industrial Controls For resistive loads: 3RF20, 3RF21, 3RF22 Solid-State Relays 3RF23, 3RF24 Solid-State Contactors · 3RF29 Function Modules For switching motors: 3RF24 Solid-State Contactors and Solid-State Reversing Contactors 5 System Overview 3RT, 3TB, 3TF Contactors for Measuring Switching Motors SENTRON PAC3200 Multifunction Instruments New 3RA13, 3RA14, 3TD, 3TE Contactor Assemblies 3RT, 3RH, 3TB, 3TC, 3TH, 3TK Contactors for Special Applications 3RH, 3TH Contactor Relays · 3RT Coupling Relays 3TX7, 3RS18 Coupling Relays LZS, LZX Plug-In Relays · 3TG10 Power Relays/Miniature Contactors Controls Power Distribution Boards, 14 4SIVACON Busway Solid-State Systems Switching and Cubicle Devices Systems Controls Solid-State Switching Devices PG 041, 101 4 AS-Interface MotorECOFAST Starter ESSystem SIRIUS ECOFAST ESSafety Integrated PROFIBUS SIMOCODE ES SIRIUS Modular Modular Safety SystemSystem ES Soft Starter ES Controls Management – System 13 3Power Contactors and Contactor Assemblies PG 041, 101, 102, 103 Controls Contactors and Contactor Assemblies PG 041, 101, 102, 103, 121, 131 ... 3 Systems Software 12 2Engineering Planning and Configuration with SIRIUS AS-Interface ECOFAST System SIRIUS Safety Integrated PROFIBUS SIRIUS Modular System PG 101, 102, 121, 131, 192, 200 ... Systems 4AV Non-Stabilized Siemens Automation Power and Supplies Drives. Welcome. 6EP Stabilized Increase your Power competitiveness. Supplies Totally Integrated Automation. - SITOP Integrated power distribution from a single source. TIP. - LOGO!Power Low-voltage controls - For advanced solutions SIRIUS industrial controls Low-voltage power distribution PG 102, 121, 574 2 Introduction Supplies 11 1Power © Siemens AG 2008 Answers for Industry. Low-Voltage Controls and Distribution. The basis for progressive solutions. PG 101, 102, 121 Introduction PG 104, 114 1 © Siemens AG 2008 Explanations ■ General information Things you should know about Catalog News LV 1 N · 06/2008 Catalog News LV 1 N · 06/2008 contains commercial and technical information on the products listed in it. The section "Catalog" contains selection and order-relevant data under the topic headings "Overview", "Benefits", "Application", "Selection and ordering data", "Options" and "Accessories". The topics "Design", "Function", "Configuration", "Technical specifications", "Characteristic curves", "Dimensional drawings", "Schematics" and "More information" can be found if required in the integrated Technical Information. Delivery time class (DT) } Preferred type A 2 working days B 1 week C 3 weeks D 6 weeks X On request Preferred types are available immediately from stock, i.e. are dispatched within 24 hours. Normal quantities of the products are usually delivered within the specified time following receipt of your order at our branch. In exceptional cases, the actual delivery time may differ from that specified. The delivery times apply up to the ramp at Siemens AG (products ready for dispatch). The transport times depend on the destination and type of shipping. The standard transport time for Germany is 1 day. The delivery times specified here represent the state of 10/2007. They are permanently optimized. For more up-to-the-minute information, please visit our site at: http://www.siemens.com/automation/mall. Price units (PU) The price unit defines the number of units or meters to which the specified price and weight apply. Package sizes (PS) The package size defines the number, e.g. of units or meters, for outer packaging. Only the quantity defined by the package size or a multiple thereof can be ordered! Price groups (PG) Each product is assigned to a price group. Weight The defined weight in kg refers to the price unit (PU). Dimensions All dimensions in mm. 4 Siemens LV 1 N Power Management System · 06/2008 For multi-unit packing and reusable packaging see see LV 1 · 2008, Appendix. © Siemens AG 2008 Explanations ■ Order number index including export markings Order No. Export markings ECCN Page AL 3Z 3ZS On req. 13/7 7K 7KM21 11 N 7KM21 12-0BA00-2 On req. N 13/4 7KM21 12-0BA00-3 5D992B1 N 13/4 7KM93 00-0AB N N 13/5 7KM93 00-0AM N N 13/6 13/4 Siemens LV 1 N Power Management System · 06/2008 5 © Siemens AG 2008 Notes 6 Siemens LV 1 N Power Management System · 06/2008 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments Catalog 13/2 13/3 13/4 13/4 13/4 13/5 13/5 13/5 13/6 13/6 13/6 13/7 13/7 13/7 Technical Information 13/8 13/9 13/10 13/11 13/12 13/16 13/17 13/20 13/20 13/20 13/21 13/21 13/21 13 PAC3200 multifunction measuring instruments - Overview - Benefits - Application - Selection and ordering data - More information Expansion modules PAC PROFIBUS DP - Overview - Application - Selection and ordering data PAC RS485 - Overview - Application - Selection and ordering data Software SIMATIC PCS 7 Library PAC3200 - Overview - Application - Selection and ordering data PAC3200 multifunction measuring instruments - Design - Function - Integration - Configuration - Technical specifications - Dimensional drawings - Schematics Expansion modules PAC PROFIBUS DP - Technical specifications - Dimensional drawings - More information PAC RS485 - Technical specifications - Dimensional drawings - More information Siemens LV 1 N Power Management System · 06/2008 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments ■ Overview 13 Measuring precisely with SENTRON PAC3200 - New dimensions with the multifunction measuring instrument The SENTRON PAC3200 is a control panel instrument for measuring and indicating more than 50 electric power distribution variables such as voltage, current, power, electrical work and frequency with their minimum, maximum and mean values. It convinces through its compact design and high performance capacity. A large, backlit graphic display can be read even from great distances. User-friendly, intuitive operation is made possible by plain text displays in nine languages in combination with four function buttons. Language selection is possible either directly on the device or using configuration software. SENTRON PAC3200 offers several communication options in addition to one digital input and one digital output. For integration in a higher-level power management system it is possible to use either the integrated Ethernet interface or the optionally available expansion modules. SENTRON PAC3200 is also available with UL and CSA approval for use in the USA and Canada. The SENTRON powerconfig software for user-friendly device configuration is included in the scope of supply. The product variants of the SENTRON PAC3200 PAC3200 Type With AC/DC power supply unit with wide voltage range and screw terminals 7KM21120BA003AA0 • UAUX: 95 ... 240 V AC ±10 %, 50/60 Hz 110 ... 340 V DC ±10 % • Ue: max. 3 AC 690/400 V, 50/60 Hz With DC power supply unit with extra-low voltage and screw terminals With screw terminals • UAUX: 22 ... 65 V DC ±10 % max. 3 AC 500/289 V 7KM21111BA003AA0 • Ue: With AC/DC power supply unit with wide voltage range and cable lug terminals • UAUX: 95 ... 240 V AC ±10%, 50/60 Hz 110 .... 340 V DC ±10 % • Ue: 7KM21120BA002AA0 max. 3 690/400 V AC, 50/60 Hz With cable lug terminals More information is available on the Internet at: www.siemens.com/powermanagementsystem 13/2 Siemens LV 1 N Power Management System · 06/2008 The advantages of the SENTRON PAC3200 at a glance: • Three-phase control panel measuring device for measuring electrical variables • Measuring more than 50 variables such as phase voltage and phase-to-phase voltage, current, power, work, power factor, frequency, etc. • High measuring accuracy for electrical work; Class 0.5S according to IEC 62053-22 • Can be used for single-phase measurements as well as for multiphase measurements in 3 and 4-conductor networks • Can be connected directly to three-phase industrial networks up to 690/400 V or up to max. 500/289 V for devices with DC power supply unit with extra-low voltage (CATIII) • Measuring higher voltages using a voltage transformer; adjustable transformer ratio • For x/1A and x/5A current transformers; adjustable transformer ratio and current direction • 2 device types available with power supply unit with wide voltage range and with extra-low voltage in order to cover all standard AC and DC auxiliary voltage supply needs • Slot for expansion modules such as the SENTRON PAC PROFIBUS DP or SENTRON PAC RS485 communication modules • Small space requirement thanks to compact design (96 mm x 96 mm, mounting depth 51 mm or 73 mm with module) • Large, graphic LCD display with intuitive user operation using function buttons • Menu selections, test displays and documentation available in nine languages (German, English, Portuguese, Turkish, Spanish, Italian, French, Chinese and Russian) Language selection on the device or using configuration software • IP65 using standard sealing • Multifunctional digital input, for example for detecting counting pulses or for monitoring the status of switching devices • Multifunctional digital output, for example for emitting active or reactive power pulses (S0) or for indicating limit value violations • Monitoring of up to 6 limit values and connecting the limit values with logical AND / OR operations • Measuring period averages for active and reactive power with minimum and maximum value • Operating hours meter for indicating the load running time • Integrated Ethernet interface (Modbus TCP or SEAbus TCP) for integration in power management systems • UL and CSA approval for the USA and Canada • CD with SENTRON powerconfig software for user-friendly device configuration included in scope of supply © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments Measurement functions The SENTRON PAC3200 measures the following variables: Current Voltage L-N Voltage L-L Frequency Active power per phase input "+" / output "-" Reactive power per phase pos./neg. or ind./cap. Apparent power per phase Active power total input "+" / output "-" Reactive power total pos./neg. or ind./cap. Apparent power total Power factor per phase Power factor total Active work total input "+" / output "-" Reactive work total pos./neg. or ind./cap. Apparent work total THD voltage per phase THD current per phase Voltage asymmetry Current asymmetry Operating hours Universal counter 1) 2) 3) Display range L1/L1-2 L2/L2-3 L3/L3-1 0 A ………120 kA 0 V …….. 700 kV 0 V …..… 1200 kV 44.00 … 67.00 Hz 0 W ….. 100 GW ✓ ✓ ✓ ✓ ✓ ✓ Total Minimum Mean value value Maximum value ✓ ✓1) ✓ ✓1) ✓ ✓ ✓1) ✓ ✓ ✓ ✓ --- ✓ ✓ -- -- ✓ ✓ ✓ ------ 0 var … 100 Gvar ✓ ✓ ✓ -- ✓ -- ✓ 0 VA … 100 GVA 0 W … 100 GW ✓ ✓ ✓ -- ✓ -- ✓ -- -- -- ✓ ✓ ✓2) ✓ 0 var … 100 Gvar -- -- -- ✓ ✓ ✓2) ✓ 0 VA … 100 GVA 0 …1 0 …1 0 Wh … 1000 GWh -- -- -- ✓ ✓ ✓ ✓ -- ✓ --- --- --- ✓ ✓ ✓3) -- ----- ✓ ✓ 0 varh … 100 Gvarh -- -- -- ✓3) -- -- -- 0 VAh … 100 GVAh 0 … 100 % 0 … 100 % 0 … 100 % 0 … 100 % 0 h … 300 years 0 … 999,999,999 pulses -- -- -- ✓3) ✓ ✓ ✓ ✓ ✓ --- ----- ----- ----- -------- -------- -- ✓ ✓ The values quoted are mean values of all three phases. Can be called up only through communication. The power averages (power count values), including minimum and maximum values, are transmitted for a selectable measurement period. The measurement period can be selected in the range 1 … 60 min; the default setting is 15 min. ✓ ✓ ✓ ✓ ✓ ✓ ✓ 13 Variable ✓ ✓ -- ✓ ✓ ----- ✓ Measuring possible -- Measuring not possible or not meaningful The values for high rate and low rate are shown on the display. ■ Benefits • Thanks to the wide range of functions, only one device variant is required for different measuring tasks – this saves storage costs and procurement costs. • Easy and quick mounting saves installation costs. • Connection to power supply networks up to 690 V1) without a voltage transformer saves space in the control cabinet and costs (transformer costs, transformer mounting and installation costs). • Comprehensive and precise power measurements form the basis for identifying savings potential in the system. • The many different measuring and monitoring functions of the SENTRON PAC3200 contribute indirectly to a higher level of availability because faults are detected early. • With its technical configuration, various approvals and certifications such as UL and CSA for the USA and Canada, and support for nine languages, the SENTRON PAC3200 can be used world-wide. • A large, illuminated graphic display guarantees good reading even in poor light conditions and opens up a wider application area for the device. • Through the multilingual, intuitive user operation of the PAC3200, valuable time can be saved during start-up and operation. • Thanks to the network-capable Ethernet interface, which is included without additional price in every standard device, the costs for system integration can be lowered. At the same time the high transmission speed helps to increase the performance of the overall system notably. • The SENTRON powerconfig configuration software makes it easier to configure the devices. This results in considerable time savings, particularly when several PAC3200 units have to be configured. • Easy integration in automation systems or power management systems, for example SIMATIC WinCC powerrate or SIMATIC PCS 7, is favored by the optional PAC PROFIBUS DP and PAC RS485 expansion modules interface, thus saving time and implementation costs. • The SENTRON PAC3200 has a mounting depth of only 51 mm which means that it can also be installed in equipment with little depth. 1) Max. 500 V (UL-L) for version with DC power supply unit with extra-low voltage (7KM2111-1BA00-3AA0) Siemens LV 1 N Power Management System · 06/2008 13/3 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments 13 ■ Application Three-phase multifunction measuring instruments are used to measure and indicate all relevant network parameters of an electrical installation and they monitor these parameters permanently. for power management systems and for plant and building automation. Uses Power distribution systems for the power supply are needed in all sectors of industry. SENTRON PAC3200 is used accordingly in all sectors where power consumption and electrical parameters are to be measured. Wherever power has to be distributed, be it in industrial or infrastructural buildings, the SENTRON PAC3200 supplies important information to the building services system or the power controlling system. Industries The many different communication options offered by the SENTRON PAC3200 make it an indispensable supplier of data ■ Selection and ordering data Version DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg 7KM2112-0BA00-3AA0 SENTRON PAC3200 Screw terminals A Control panel instrument 96 mm x 96 mm Screw terminals for connecting current and voltage 7KM2112-0BA00-3AA0 1 1 unit 133 0.325 1 1 unit 133 0.325 1 1 unit 133 0.325 AC/DC power supply unit with wide voltage range UAUX: 95 … 240 V AC ±10 %, 50/60 Hz 110 … 340 V DC ±10 %, 50/60 Hz Measuring inputs Ue: max. 3 AC 690/400 V, 50/60 Hz Ie: /1 A or /5 A SENTRON PAC3200 Screw terminals A Control panel instrument 96 mm x 96 mm Screw terminals for connecting current and voltage 7KM2111-1BA00-3AA0 DC power supply unit with extra-low voltage UAUX: DC 22 … 65 V ±10 % 7KM2111-1BA00-3AA0 Measuring inputs Ue: max. 3 AC 500/289 V, 50/60 Hz Ie: /1 A or /5 A Cable lug terminals SENTRON PAC3200 Control panel instrument 96 mm x 96 mm Cable lug terminals for connecting current and voltage 7KM2112-0BA00-2AA0 A 7KM2112-0BA00-2AA0 AC/DC power supply unit with wide voltage range UAUX: 95 … 240 V AC ±10 %, 50/60 Hz 110 … 340 V DC ±10 % Measuring inputs Ue: max. 3 690/400 V AC, 50/60 Hz Ie: /1 A or /5 A ■ More information Suitable current transformers can be found • in Catalog LV 1 2008, section "SIVACON Power Distribution Boards, Busway and Cubicle Systems" --> "Components for 8US, 8UC 4NC Distribution Systems, 4NC Current Transformers for Measuring Purposes" • in the A&D Mall, section "Low-Voltage Controls" --> "Low-Voltage Power Distribution" --> "SIVACON Power Distribution Boards, Busway and Cubicle Systems" -->"Components for 8US, 8UC, 4NC Distribution Systems" --> "4NC Current Transformers for Measuring Purpose". * You can order this quantity or a multiple thereof. 13/4 Siemens LV 1 N Power Management System · 06/2008 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments Expansion modules PAC PROFIBUS DP The PAC PROFIBUS DP expansion module has the following features: • PROFIBUS DP plug-in communication module for SENTRON PAC3200 • Parameterizable from the front of the device or using parameterization software • Using PROFIBUS DPV1, data can be transferred in both cyclic and acyclic modes • Easy integration using GSD file, with free choice of the measurement variables to be transmitted • Plug and play • All baud rates from 9.6 Kbit/s to 12 Mbit/s are supported • Connection through 9-pole Sub-D connector according to IEC 61158 • No external auxiliary power necessary • Status indication by LED on the module ■ Application The SENTRON PAC PROFIBUS DP communication module is plugged onto the rear of the PAC3200 multifunction measuring instrument. The device identifies the module automatically and presents the parameters of relevance for this module for selection in the parameterization menu. All measurement variables supplied by the PAC3200 are selected and cyclically or acyclically transmitted by means of the GSD file. The state of the module is indicated by an LED. ■ Selection and ordering data Version DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg PAC PROFIBUS DP Expansion module for SENTRON PAC3200 (PROFIBUS DPV1) A 7KM9300-0AB00-0AA0 1 1 unit 133 0.045 7KM9300-0AB00-0AA0 * You can order this quantity or a multiple thereof. Siemens LV 1 N Power Management System · 06/2008 13/5 13 ■ Overview © Siemens AG 2008 SENTRON Multifunction Measuring Instruments Expansion modules PAC RS485 ■ Overview 13 The PAC RS485 expansion module has the following features: • PAC RS485 plug-in communication module for SENTRON PAC3200 • Parameterizable from the front of the device or using parameterization software • Modbus RTU and SEAbus protocols are supported • Plug and play • Baud rates of 4.8 / 9.6 / 19.2 and 38.4 kBd are supported • Connection by means of 6-pole screw terminals • No external auxiliary power necessary • Status indication by LED on the module ■ Application The SENTRON PAC RS485 communication module is plugged onto the rear of the PAC3200 multifunction measuring instrument. The device identifies the module automatically and presents the parameters of relevance for this module for selection in the parameterization menu. The state of the module is indicated by the integrated LED. In connection with the PAC3200, the Modbus RTU and SEAbus protocols are supported with baud rates of 4.8 / 9.6 / 19.2 and 38.4 kBd. ■ Selection and ordering data Version DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg PAC RS485 Expansion module for SENTRON PAC3200 (SEAbus and Modbus RTU) A 7KM9300-0AM00-0AA0 1 1 unit 133 0.041 7KM9300-0AM00-0AA0 * You can order this quantity or a multiple thereof. 13/6 Siemens LV 1 N Power Management System · 06/2008 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments Software SIMATIC PCS 7 Library PAC3200 ■ Overview Features • Full integration of SENTRON PAC3200 in the PCS 7 process control system through PROFIBUS DPV1 using a certified PCS 7 add-on module • Reading out and displaying device data • Inputting limit values – for monitoring through the driver block • Resetting values on the device (min/max values) 13 Product components: • Driver block • Diagnostics block • Faceplates ■ Application The PCS 7 function block library − SIMATIC PCS 7 Library PAC3200 − for the SENTRON PAC3200 multifunction measuring instrument enables the seamless integration of the multifunction instrument in the PCS 7 process world. It comprises one driver block, one diagnostics block and the faceplates. The blocks in the SIMATIC S7 supply energy data to the faceplates in the user interface of the process control system, generate signals and guarantee connection to the maintenance system of PCS 7. Between the driver and the SENTRON PAC3200 there exists a bilateral communication connection which permits not only the transfer of measured values and states from the device but also the changing of for example limit values in the device. Faceplates Faceplates serve as a user interface for operating and monitoring and enable technologically important values and functions of the SENTRON PAC3200 to be displayed and performed as a PCS 7 object. Between the driver and faceplates there exist on the system side bidirectional communication connections not only for displaying values in the faceplates but also for forwarding input data from the operator. This makes the SENTRON PAC3200 power monitoring device an integral component of PCS 7. System requirements The SIMATIC PCS 7 Library PAC3200 runs with • PCS 7 V6.1 SP1 (and higher) and • PCS 7 V7.0 (and higher). Supported operating systems are the same as for SIMATIC PCS 7, see Catalog ST PCS 7 or the Mall, section "Automation Systems" --> "Process Automation" --> "Process Control Systems". ■ Selection and ordering data Version DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg SIMATIC PCS 7 Library PAC3200 Engineering + Runtime license 3ZS2781-1CC10-0YG0 1 1 unit 133 0.250 3ZS2781-1CC10-6YH0 1 1 unit 133 0.250 SIMATIC PCS 7 Library PAC3200 Runtime license * You can order this quantity or a multiple thereof. Siemens LV 1 N Power Management System · 06/2008 13/7 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments ■ Design Enclosures Operating and indicating elements SENTRON PAC3200 comes with a plastic enclosure for installation in control panels. It is fastened by one holder on the right side of the device and one on the left side. The following picture shows the SENTRON PAC3200 from the front, divided into the function blocks provided for operation and monitoring, including a description. The header bar shows in plain text which measurement values are presented in the current display. For easier navigation, the menu number of the display is shown on the far right. 2 The measured values with phase identifer and unit of measurement are shown in the middle of the display. The scrollbar and the menu number in the display header together indicate in which display or parameter menu you are, thus enabling fast and selective navigation. NSE0_01953 Four function buttons with context-sensitive descriptions for operating the device. $ % NSE_01947 13 1 Opening in the device for attaching the mounting holder Device holder with retention lugs Mounting the SENTRON PAC3200 Front of the SENTRON PAC3200 To mount the SENTRON PAC3200 it is inserted from the front through the square cut-out in the control cabinet door and secured with the supplied holders. The device is operated using 4 function buttons, which correspond to the 4 text fields situated above them. The buttons are each assigned with several functions; their function at any time depends on the menu then displayed. Which function a button has in the respective menu is indicated by the text in the related display. From the front, i.e. in the installed state, the device complies with Safety Class II with degree of protection IP65. The following picture shows how to join together the SENTRON PAC3200 and the expansion module in the light of the rear view of the SENTRON PAC3200 and the top view of the expansion module (here: PAC PROFIBUS DP). 0,5 Nm 2x SN62217-B3x22 $ % & ( NSE0_01952 Device and module enclosure Fixing screws and related holes in the enclosure PROFIBUS connectors Fixtures for the PROFIBUS connector Mounting the expansion module based on the example of the PAC PROFIBUS DP on the SENTRON PAC3200 13/8 Siemens LV 1 N Power Management System · 06/2008 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments Precise measurement of variables Mounting and start-up in the shortest possible time With its high accuracy, the SENTRON PAC3200 meets the increasing demand for precise power measurement. It satisfies the accuracy requirements of Class 0.5S according to IEC 62053-22 for solid-state active consumption meters. With its ingenious mounting method the SENTRON PAC3200 is quick and easy to install using combination latching holders. Transparency in power matters Altogether 10 power meters for active, reactive and apparent work monitor the power consumption in the system, separately according to the high rate and low rate, for both power input and power feedback. This makes the SENTRON PAC3200 the optimum choice of data supplier for a higher-level power management system. Integrated in such a system it enables the user to record his installation's load profile. For this purpose the SENTRON PAC3200 also supplies the required power averages for active and reactive power. The pair of combination holders performs two functions: • Thanks to the latching mechanism the fitter can fasten the device in the control panel quickly and without the use of any tools. • If greater protection is required, the four screws of the latching holder can be used to increase its contact pressure evenly on all sides so that the control panel cut-out is cleanly sealed by the integrally molded gasket, which is a standard feature. The often bothersome and time-consuming insertion of an accessory gasket is a thing of the past. As the result of the easy-to-use combination holders and the small mounting depth of only 51 mm it is easy to mount several devices side by side. Plain-text displays Powerful communication A large, full graphic LCD display enables easy reading even from great distances. To make sure that this is also the case in poor light conditions, the background lighting can be individually adapted to the actual requirements. Unique in this device class up to now is the Ethernet interface provided as a standard feature which can be used not only for configuration purposes using SENTRON powerconfig but also for system communication in a higher-level power management system. For optimum system adaptation it is possible to switch between the SEAbus TCP protocol and the Modbus TCP protocol. Operation, also multilingual A special highlight is the intuitive user operation. Operation is quick to learn using the four function buttons together with multilingual plain text displays. Following languages can be selected: German, English, Portuguese, Turkish, Spanish, Italian, French, Chinese and Russian. The optional SENTRON PAC PROFIBUS DP and PAC RS485 expansion modules for Modbus RTU and SEAbus are available for communication in a network. Integration in PROFIBUS takes place using a standardized text file called the GSD (Geräte-Stammdaten-Datei). This GSD file is read into the master with the help of the PROFIBUS configuration tool. The master thus receives the slave-specific framework of the PAC3200 and can start cyclic operation immediately. Integration in Modbus RTU or SEAbus systems takes place through parameterization of the device address and baud rate using the device keyboard or SENTRON powerconfig. Multifunctional digital input and output The SENTRON PAC3200 is equipped with one digital input and one digital output, to each of which various functions can be assigned. Operating languages of the PAC3200 Direct navigation is available in addition for the experienced user, who can thus call up the menus of choice even more quickly. Functions of the digital input: • Counting input for work pulses (kWh, kvarh) from third-party devices • Status monitoring of a switching device • Rate switchover between high rate and low rate • Signal input for synchronization of the measurement period Functions of the digital output: • Pulse output for sending work pulses (kWh, kvarh) • Alarm output for signaling limit value violations • SENTRON PAC3200 operating state indicator • Phase sequence indicator • Switching output for remote control using system software With its wide range of functions, the SENTRON PAC3200 can be used in all applications. Siemens LV 1 N Power Management System · 06/2008 13/9 13 ■ Function © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments Monitoring of measurement variables for limit value violations 13 The SENTRON PAC3200 can monitor up to 6 measurement variables for violation of an adjustable upper or lower limit value. The following variables can be monitored: voltage, current, power, power factor, THD U/I, frequency or asymmetry of voltage and current The following can be assigned to each limit value: • A measurement variable: UL-N, UL-L, IL, PL, QL, SL, LFL, THD-UL/IL for all 3 phases and UL-N, mean value, UL-L, mean value, IL, mean value, Stot, Ptot, Qtot, LFtot, frequency, asymmetry U / I • The monitoring mode (overshooting or undershooting) • A limit value • A delay time and • A hysteresis ■ Integration Using the interface modules it is possible to integrate the SENTRON PAC3200 in every I&C system or every SIMATIC S7 environment. When the SENTRON PAC3200 is fully integrated in a power management system, e.g. SIMATIC WinCC powerrate or SIMATIC PCS 7 powerrate, it monitors the power consumption. At the same time the SENTRON PAC3200 helps to monitor the operating state of the installation. Measured values, limit value violations, operating hours of a connected load or power flows are supplied by the device quickly and reliably. Faceplates In addition the limit values can be interconnected by an AND/OR logic function. Like the individual limit values, the result of the logic operation can also trigger certain actions. It is possible to select the action which will be triggered by violation of a limit value. For example, a signal can be sent through the digital output or the communication interface. The integrated universal counter can be used to total the number of limit value violations. Whether a limit value has been violated is indicated on the device. Industrial Ethernet PROFIBUS Monitoring of voltage and current for asymmetry PROFIBUS The device measures, among other things, the asymmetry of voltage and current in the network. Now that a limit value can also be assigned to these two parameters, problems due to unsymmetrical loads in the installation can be detected early and avoided. Operating hours meter An important service function is performed by the integrated operating hours counter, which can be used to monitor e.g. pumps, motors or machines. The counter measures the running time of a connected load, helping to ensure that important maintenance intervals are observed. The count can be read out and evaluated by a PC. A higher-level power management system is thus able to generate a suitable maintenance message. Universal The SENTRON PAC3200 can be used for measuring in two, three and four-conductor networks. It is capable of measuring in three phases as well as in one and two phases. Thanks to its large measuring voltage range, the device can be directly connected in every low-voltage system up to a rated system voltage of 690 V (UL-L). Higher voltages can be measured using voltage transformers. For measuring currents it is possible to use both x/1A and x/5A current transformers. Transformer ratios and current direction can be programmed on the device for adaptation to local conditions. Protection against unauthorized access The SENTRON PAC3200 comes with integrated password protection so that the power and parameter data are safe from unauthorized access. Changes to the parameterization can be traced using a configuration counter which can be read out through an interface. 13/10 Siemens LV 1 N Power Management System · 06/2008 S7 driver / component 16(BE Integration of the SENTRON PAC3200 in SIMATIC PCS 7 / WinCC powerrate © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments ■ Configuration Configuration directly on the device Simplified making of connections through search function The SENTRON PAC3200 is designed for user-friendly configuring directly on the device. All menus are displayed in plain text and are self-explanatory. No manual is required therefore. SENTRON powerconfig comes with a search function which facilitates the finding of all PAC3200 units connected to the same network. Making the first connection is thus easier. Both the communication status and the configuration status are indicated by symbols in the tree view. With the project manager in SENTRON powerconfig it is possible to save device configurations and also to copy them if required. For the documentation of device configurations, SENTRON powerconfig has a user-friendly printing function with preview feature. Off-line device configurations Configuring interface of the SENTRON PAC3200 Configuring with SENTRON powerconfig is user-friendly The scope of supply of the PAC3200 includes the SENTRON powerconfig software for the user-friendly configuring of the PAC3200 from the PC. The software runs on the following operating systems: • Windows 2000 Professional SP4 and higher • Windows XP Professional SP2 and higher SENTRON powerconfig is available in German or English, with selection possible at any time through the Options menu. The integrated online help is likewise bilingual and describes the software's functions in detail. After SENTRON powerconfig is installed, the PAC3200 can be connected to the PC in two ways: • Using a commercially available crossover cable which connects the PAC3200 directly to the network interface of the PC • Or using a hub/switch in an Ethernet network. In this case conventional patch cables are used. 6(17521 SRZHUFRQILJ (WKHUQHW (WKHUQHW &URVVRYHUFDEOH Using the offline device configurations, all the devices of a plant can be configured in the comfort of the office as follows: • Creating the offline device configurations: All available devices and expansion modules are grouped in a library. The required PAC3200 units are selected from the library and moved into the device tree by means of Drag & Drop. Expansion modules can be added to the device tree in the same way. However, they can only be entered under a device. • Sending the offline device configurations: During start-up, the offline device configurations can be sent to the devices as soon as they are connected to SENTRON powerconfig. User interface of SENTRON powerconfig The individual subwindows can be positioned on the monitor as required, including outside the main window of SENTRON powerconfig. In this way the interface of the software can be adapted to the user's individual preferences. The figure below shows the program interface of SENTRON powerconfig by way of example. 3$& Direct connection between the PC and PAC3200 (WKHUQHW (WKHUQHW 6(17521 SRZHUFRQILJ 6ZLWFK+XE 3$& Configuring interface of SENTRON powerconfig 16*B Connection between the PC and PAC3200 through a hub/switch Note: The required cable material is not included in the scope of supply. Siemens LV 1 N Power Management System · 06/2008 13/11 13 Configuration management © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments ■ Technical specifications Measurement Networks Voltage types Only for alternating voltage systems Number of phases 1, 2 or 3-phase Number of conductors 3 or 4 conductors Load type Same or any load 4 quadrants (input and output) Quadrants Hz 13 Frequency of fundamental wave 50/60 Signal detection For power, current and voltage Seamless Curve shape Sinusoidal or distorted Measuring inputs for voltage Rated voltage 3 AC Ue (max.) Device with AC/DC power supply unit with wide voltage range Device with DC power supply unit with extra-low voltage 7KM2112-0BA00-3AA0 or 7KM2112-0BA00-2AA0 Phase/N V AC 400 (max. 347 for UL) +20 % Phase/phase V AC 690 (max. 600 for UL) +20 % Phase/N V AC 289 +20 % Phase/phase V AC 500 +20 % 7KM2111-1BA00-3AA0 CAT III Measuring category Input resistance Phase/N MΩ 1.05 Per phase mW 220 Adjustable AC A 1 or 5 With setting 1 A AC A 0.01 ... 1.2 With setting 5 A AC A 0.05 ... 6 Permanent AC A 10 For 1 second AC A 100 Per phase mVA 4 at 1A, 115 at 5A Power consumption Measuring of voltages > 690 or 500 V AC using voltage transformer Measuring inputs for current Rated current 3 AC Ie per phase Operating range current per phase Permanent load capacity Surge overload capability Power consumption CAT III Measuring category Zero point suppression Adjustable % 0 ... 10 Measuring of currents using current transformer Supply voltage AC/DC Power supply unit with wide voltage range Operating range 7KM2112-0BA00-3AA0 or V AC 95 … 240 ±10 % 7KM2112-0BA00-2AA0 V DC 110…340 ±10 % Hz 50/60 Rated frequency DC Power supply unit with extra-low voltage V DC 22 … 65 ±10 % Without optional expansion module VA 6 Including optional expansion module VA 8 Operating range 7KM2111-1BA00-3AA0 Power consumption Overvoltage category 13/12 Siemens LV 1 N Power Management System · 06/2008 CAT III © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments Fault limits Voltage % ±0.3 Current % ±0.2 Rating % ±0.5 Frequency % ±0.05 Power factor % ±0.5 Active energy Class 0.5S according to IEC 62053-22:2003-01 Reactive energy Class 2 according to IEC 62053-23:2003-01 13 When taking measurements on external current or voltage transformers, the accuracy of the measurements depends on the quality of the transformers. Digital input 1 Number Rated value V DC 24 Max. input voltage V DC 30 Input threshold signal "1" V DC > 13 Input threshold signal "0" V DC <8 Input current signal "1" DC mA 7 Digital output 1 Number Required voltage V DC 12 ... 24 Max. switched output voltage V DC 30 Output current signal "0" DC mA Max. 0.2 Output current signal "1" Typical Permanent Short-time overload for max. 100 ms Resistive load DC mA DC mA DC mA DC mA 10 ... 27 100 300 100 Switching frequency Hz 17 Yes Short-circuit protection Communication RJ45 socket MBit/s 10 Either SEAbus TCP or Modbus TCP (selectable) Ethernet Transmission rate max. Protocol PROFIBUS DP Using expansion module Transmission rate max. Variables to be transmitted RS485 Using expansion module Transmission rates Protocol PAC PROFIBUS DP V1 MBit/s 12 Definable using GSD file PAC RS485 kBd Optionally 4.8 /9.6 /19.2 / 38.4 Optionally SEAbus or Modbus RTU (selectable) Indicating and operating LCD, full graphic Display type Alphanumeric and text Displays Resolution Dots 128 x 96 Size mm 72 x 54 Contrast Adjustable Display Display invertible, pos/neg mode Background lighting Lighting intensity Lighting intensity dimmed Dimming time Adjustable Adjustable 0 ... 99 Languages min German, English, Portuguese, Turkish, Spanish, Italian, French, Chinese and Russian Siemens LV 1 N Power Management System · 06/2008 13/13 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments Connection elements and terminals Measuring inputs and supply voltage Conductor cross-sections Screw terminals mm2 Solid 1 x 0.5 ... 4 AWG 1 x 20 ... 12 mm2 2 x 0.5 ... 2.5 AWG 2 x 20 ... 14 Finely stranded with end sleeve mm2 1 x 0.5 ... 2.5 AWG 1 x 20 … 12 mm2 2 x 0.5 ... 1.5 ± screw, Pozidriv 2 Ring terminal lug connections Measuring inputs and supply voltage Conductor cross-sections mm2 Dependent on ring terminal lug used 1 x 1.0...6.0 AWG 1 x 18...10 / mm D: 3...4 NO: 0,75 ... 1.0 W: ≤ 8 L1: ≤ 24 L2: ≤ 20 L3: ≥ 8 Inch D: 0,118 ... 0,157 NO: 0.029 ... 0.039 W: ≤ 0.314 L1: ≤ 0.944 L2: ≤ 0.787 L3: ≥ 0.314 / ' Tool size NSG0_00229 : / 6 13 AWG 2 x 20 … 16 Tool size 2 ± screw, Pozidriv Screw terminals Digital output, digital input Conductor cross-sections Solid mm2 1 x 0.2 … 2.5 mm2 2 x 0.2 … 1.0 AWG 1 x 24 ... 12 Finely stranded with end sleeve mm2 1 x 0.25 … 2.5 mm2 2 x 0.25 … 1.0 AWG 1 x 24 … 12 Tool size ± screw, Pozidriv 1 Dimensions and weights According to IEC 61554 Enclosure for installing in control panel Enclosure dimensions (W x H x D) Without expansion module With expansion module mm mm 96 x 96 x 56 96 x 96 x 78 Mounting depth Without expansion module With expansion module mm mm 51 73 Control panel thickness mm 0.5 … 4 g g 325 370 Weight Without expansion module With expansion module Approx. Approx. Degree of protection and safety class Safety class according to EN 61010-1 From the front when installed Degree of protection according to EN 60529 All devices Device with screw terminals Device with cable lug terminals 13/14 II Mountable on front Rear Rear Siemens LV 1 N Power Management System · 06/2008 IP65 IP20 IP10 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments Ambient conditions Temperature range Operating temperature Storage and transport temperature °C °C -10 … +55 -25 … +70 Relative air humidity At 25 °C without condensation % 95 Operating altitude Above sea level up to max. m 2000 2 Degree of pollution Safety 13 4-digit numeric code Password protection Safety requirements Verification of suitability as EC conformity declaration Device test according to the following standards IEC 61010-1:2001 (2nd Ed.) with Corr.1 EN 61010-1-1:2001 (2nd Ed.) EN 61010-1:2002 with Corr.1 Verification of suitability as approval for the USA and Canada UL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-04 Electromagnetic compatibility IEC 61000 6-4 Group 1; Class A / CISPR11 Group 1; Class A FCC Part 15 Subpart B; Class A Emitted interference Enclosure interference immunity Electrostatic discharge IEC 61000-4-2:2001-04 Electromagnetic fields IEC 61000-4-3:2006-02 Line-frequency magnetic fields IEC 61000-4-8:2001-03 Measuring and supply voltage Voltage dips IEC 61000-4-11:2004-03 Rapid transients EN 61000-4-4:2005-07 Surge voltages EN 61000-4-5:2001-12 Line-conducted RF signals EN 61000-4-6:2001-12 Inputs and outputs, interfaces Rapid transients IEC 61000-4-4:2004-07 Surge voltages IEC 61000-4-5:2005-11 Line-conducted RF interference fields EN 61000-4-6:2001-12 Mechanical dynamic stress Vibratory load Conditions of use/transport According to IEC 60068 Part 2-6:1995-03 / EN 60068 Part 2-6:1996-05 Seismic stress According to IEC 60068 Part 3-3:1991-02 / EN 60068 Part 3-3:1993-09 Shock stress According to IEC 60068 Part 2-27:1987 / EN 60068 Part 2-27:1995-03 Bumping, resistance According to IEC 60068 Part 2-27:1987 / EN 60068 Part 2-27:1995-03 According to IEC 60068-2-29:1987 / EN 60068 Part 2-29:1995-03 Continuous bumping Mechanical strength Against surges and shocks According to IEC 60068-2-75:1997-08 Siemens LV 1 N Power Management System · 06/2008 13/15 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments ■ Dimensional drawings Dimensions of multifunction measuring instrument 51 F3 91 96 F4 96 51 10 F2 NSE0_01955 F1 91 96 13 73 73 Left: Front view; middle: PAC3200 with screw terminals, view from the right; right: PAC3200 with cable lug terminals, view from the right max. 4 mm 70 92+0,8 Cut-out from the front Left: PAC3200 with screw terminals, view from the right Right: PAC3200 with cable lug terminals, cut-out from right Mounting clearances 13/16 F2 F3 F4 NSE_01958 135 F1 70 NSE0_01956 NSE_01957 92+0,8 max. 4 mm 70 Control panel cut-out, lateral 70 Control panel cut-out F1 F2 F3 Siemens LV 1 N Power Management System · 06/2008 F4 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments ■ Schematics Connection examples Connection example 1: Connection example 4: Three-phase measurement, four conductors, asymmetric load, without voltage transformer, with three current transformers Three-phase measurement, four conductors, symmetric load, with voltage transformer, with one current transformer ; ; ; 13 ; ) ) ) ) ) ) /D /E /F ) /D /E /F 1Q 1Q Connection example 2: Connection example 5: Three-phase measurement, four conductors, asymmetric load, with voltage transformer, with three current transformers Three-phase measurement, three conductors, asymmetric load, without voltage transformer, with three current transformers ; ; ; ) ) ) ) ; ) ) ) ) /D /E /F ) ) ) /D /E /F 1Q Connection example 3: Connection example 6: Three-phase measurement, four conductors, symmetric load, without voltage transformer, with one current transformer Three-phase measurement, three conductors, asymmetric load, with voltage transformer, with three current transformers ; ) /D /E /F 1Q * Fuses must be provided by the user. ; ; ; ) ) ) ) ) ) ) ) /D /E /F ** Connection of the supply voltage Siemens LV 1 N Power Management System · 06/2008 13/17 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments Connection example 7: Connection example 10: Three-phase measurement, three conductors, asymmetric load, without voltage transformer, with two current transformers Three-phase measurement, three conductors, symmetric load, with voltage transformer, with one current transformer ; ; ; ; ) ) ) 13 ) ) ) ) ) /D /E /F ) ) ) /D /E /F Connection example 8: Connection example 11: Three-phase measurement, three conductors, asymmetric load, with voltage transformer, with two current transformers Two-phase measurement, three conductors, asymmetric load, without voltage transformer, with two current transformers ; ; ) ) ) ; ) ; ) ) ) /D /E ) ) ) /D /E /F 1Q Connection example 9: Connection example 12: Three-phase measurement, three conductors, symmetric load, without voltage transformer, with one current transformer Single-phase measurement, two conductors, without voltage transformer, with one current transformer ; ; ) ) ) ; ) ; ) ) /D /D /E /F 1Q * Fuses must be provided by the user. 13/18 Siemens LV 1 N Power Management System · 06/2008 ** Connection of the supply voltage © Siemens AG 2008 SENTRON Multifunction Measuring Instruments PAC3200 multifunction measuring instruments Connection example 13: Three-phase measurement, four conductors, asymmetric load, with voltage transformer, with three current transformers 13 14 15 16 17 ; ) 13 ) ) ) NSE_01951 ; ) ) ) /D /E /F 1Q * Fuses must be provided by the user. 1 2 3 4 5 6 7 8 9 10 11 12 ** Connection of the supply voltage Fusing of the supply voltage input: Fuse holders Cylindrical fuse links 3NW7-5130HG 3NW1006-0HG (0.6A) Connection graphics 8 1 7 Terminal Function $ % & ( ) * + Phase current, IL1, input Phase current, IL1, output Phase current, IL2, input Phase current, IL2, output Phase current, IL3, input , . / IL1 k IL1 l IL2 k IL2 l IL3 k IL3 l V1 V2 V3 VN L/+ 0 N/- 1 2 3 4 5 DIDI+ DODO+ Phase current, IL3, output Phase voltage UL1 Phase voltage UL2 Phase voltage UL3 Neutral conductor UN AC: Connection: Conductor (phase voltage) DC: Connection: + AC: Connection: Neutral conductor DC: Connection: Functional ground Digital input Digital input + Digital output Digital output + PAC3200 terminal assignment in detail NSE_01950 1 No. 2 6 5 4 3 No. $ % & ( ) * + Function Digital inputs and outputs, functional ground Slot not assigned Supply voltage L/+, N/Measuring inputs voltage V1, V2, V3, VN Measuring inputs current IL1, IL2, IL3 Slot for optional expansion modules Optional expansion module, not included in the scope of supply , Ethernet interface PAC3200 terminal assignment in overview Siemens LV 1 N Power Management System · 06/2008 13/19 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments Expansion modules PAC PROFIBUS DP ■ Technical specifications Communication PROFIBUS DP Transmission rate max. MBit/s 12 Protocol PROFIBUS DPV1 Variables to be transmitted Definable using GSD file Enclosure dimensions (W x H x D) Module enclosure for plugging onto the PAC3200 mm 43 x 63 x 22 Weight approx. g 45 Degree of protection IP20 Degree of protection according to EN 60529 Ambient conditions Temperature range Operating temperature °C -10 … + 55 Storage and transport temperature °C -25 … + 70 % 95 m 2000 Relative air humidity At 25 °C without condensation Operating altitude Above sea level up to max. 2 Degree of pollution ■ Dimensional drawings Dimensions of the plug connector between the PAC PROFIBUS DP expansion module and the PAC3200 63 22 43 ■ More information More information can be found on the Internet at www.siemens.com/powermanagementsystem 13/20 Siemens LV 1 N Power Management System · 06/2008 7,5 6,44 NSE_01949 6 Dimensions of PAC PROFIBUS DP expansion module at the side and from above NSE_01948 13 Dimensions and weights © Siemens AG 2008 SENTRON Multifunction Measuring Instruments Expansion modules PAC RS485 ■ Technical specifications Communication RS485 Transmission rates kBd Optionally 4.8 / 9.6 / 19.2 / 38.4 Optionally SEAbus or Modbus RTU (selectable) Protocol Dimensions and weights Module enclosure for plugging onto the PAC3200 mm 43 x 63 x 22 Weight approx. g 41 13 Enclosure dimensions (W x H x D) Degree of protection IP20 Degree of protection according toEN 60529 Ambient conditions Temperature range Operating temperature °C -10 … + 55 Storage and transport temperature °C -25 … + 70 % 95 m 2000 Relative air humidity At 25 °C without condensation Operating altitude Above sea level up to max. 2 Degree of pollution ■ Dimensional drawings 6,44 NSE_02001 63 7,5 NSE_02002 Dimensions of the plug connector between the PAC RS485 expansion module and the PAC3200 11 Dimensions of PAC RS485 expansion module at the side and from above 22 43 . ■ More information More information can be found on the Internet at www.siemens.com/powermanagementsystem Siemens LV 1 N Power Management System · 06/2008 13/21 © Siemens AG 2008 SENTRON Multifunction Measuring Instruments 13 Notes 13/22 Siemens LV 1 N Power Management System · 06/2008 © Siemens AG 2008 Appendix Conditions of sale and delivery Export regulations ■ Terms and Conditions of Sale and Delivery By using this catalog you can acquire hardware and software products described therein from Siemens AG subject to the following terms. Please note! The scope, the quality and the conditions for supplies and services, including software products, by any Siemens entity having a registered office outside of Germany, shall be subject exclusively to the General Terms and Conditions of the respective Siemens entity. The following terms apply exclusively for orders placed with Siemens AG. For customers with a seat or registered office in Germany The “General Terms of Payment” as well as the “General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry” shall apply. For software products, the “General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office in Germany” shall apply. For customers with a seat or registered office outside of Germany The “General Terms of Payment” as well as the “General Conditions for Supplies of Siemens, Automation and Drives for Customers with a Seat or registered Office outside of Germany” shall apply. For software products, the “General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office outside of Germany” shall apply. General The dimensions are in mm. In Germany, according to the German law on units in measuring technology, data in inches only apply to devices for export. Illustrations are not binding. Insofar as there are no remarks on the corresponding pages, - especially with regard to data, dimensions and weights given these are subject to change without prior notice. The prices are in € (Euro) ex works, exclusive packaging. The sales tax (value added tax) is not included in the prices. It shall be debited separately at the respective rate according to the applicable legal regulations. Prices are subject to change without prior notice. We will debit the prices valid at the time of delivery. Surcharges will be added to the prices of products that contain silver, copper, aluminum, lead and/or gold if the respective basic official prices for these metals are exceeded. These surcharges will be determined based on the official price and the metal factor of the respective product. The surcharge will be calculated on the basis of the official price on the day prior to receipt of the order or prior to the release order. The metal factor determines the official price as of which the metal surcharges are charged and the calculation method used. The metal factor, provided it is relevant, is included with the price information of the respective products. An exact explanation of the metal factor and the text of the Comprehensive Terms and Conditions of Sale and Delivery are available free of charge from your local Siemens business office under the following Order Nos.: • 6ZB5310-0KR30-0BA1 (for customers based in Germany) • 6ZB5310-0KS53-0BA1 (for customers based outside Germany) or download them from the Internet http://www.siemens.com/automation/mall (Germany: A&D Mall Online-Help System) ■ Export regulations The products listed in this catalog / price list may be subject to European / German and/or US export regulations. Therefore, any export requiring a license is subject to approval by the competent authorities. According to current provisions, the following export regulations must be observed with respect to the products featured in this catalog / price list: AL Number of the German Export List Products marked other than “N” require an export license. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an “AL“ not equal to “N” are subject to a European or German export authorization when being exported out of the EU. ECCN Export Control Classification Number Products marked other than “N” are subject to a reexport license to specific countries. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an “ECCN“ not equal to “N” are subject to a US re-export authorization. Even without a label or with an “AL: N” or “ECCN: N”, authorization may be required due to the final destination and purpose for which the goods are to be used. The deciding factors are the AL or ECCN export authorization indicated on order confirmations, delivery notes and invoices. Errors excepted and subject to change without prior notice. A&D/VuL_ohne MZ/En 05.09.06 © Siemens AG 2008 Get more information Low-Voltage Controls and Distribution www.siemens.com/lowvoltage Siemens AG Industry Sector Industrial Automation Systems Postfach 48 48 90026 NÜRNBERG GERMANY www.siemens.com/automation Subject to change without prior notice PDF only: (E86060-K1002-A211-A2-7600) KG 0708 28 En / 803029 © Siemens AG 2008 The information provided in this catalog contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.