DCM0035 DCM0035 - Interstate Batteries

advertisement
DCM0035
DCM0035
VALVE-REGULATED
LEAD-ACID BATTERY
FOR DEEP-CYCLE
APPLICATIONS
FEATURES
• Robust plate for extended cycle life.
• Computer-generated grid design optimized for high-power density.
• Low-calcium grid alloy for reduced gas emissions and ease of recycling.
• Flame-arresting, one-way pressure-
relief vent for safety and long life.
• UL-recognized component.
• Multicell design for economy of installation and maintenance.
• Case and cover available in standard polypropylene.
• Thermally welded case-to-cover bond to eliminate leakage.
• Removable handles.
• Can be used in any orientation. Upright, side or end mounting
recommended.
•
Absorbent Glass Mat (AGM) technol-
ogy for efficient gas recombination of up to 99% and freedom from electrolyte maintenance.
• Not restricted for air transport ­— complies with IATA/ICAO Special Provision A67.
•
Not restricted for surface transport ­— classified as nonhazardous material
as related to DOT-CFR Title 49 parts 171-189.
• Not restricted for water transport ­— classified as nonhazardous material
per IMDG Amendment 27.
• Longest cycle life available.
• Manufactured by an ISO9001 certified
facility.
12 Volts – 35 Ampere-Hour Capacity @ 20-Hour Rate
Ampere-Hour Capacity to 1.75 Volts per Cell @ 77°F (25°C)
10.5 Volts per 12 Volt Battery
20
36
Approximate Discharge in Hours
Amp-Hour Capacity
Interstate Battery
System of America, Inc.
12770 Merit Drive, Suite 1000
Dallas, TX 75251
Customer Service: 1-888-772-3600
Printed in the U.S.A.
Rev. 12/06
MR
128782
© 2006 Interstate Battery System of America, Inc. interstatebatteries.com
10
33
5
26.5
1
18
DCM0035
7.68 (195)
5.16 (131)
7.13 (181)
6.14 (156)
PT
1/4 - 20 THREAD
PT
DCM0035 – Specifications
*All dimensions in inches and (millimeters). All dimensions are for reference only.
Contact an Interstate representative for complete dimensional information.
Cells
Per Unit
Voltage Per Unit
Weight
Electrolyte
Max. Discharge
Current
Short Circuit
Current
Ohms Imped.
60 Hz
6
12
23.1 lbs.
10.5 kg
Absorbed H2SO4
SG = 1.30
175 Amps
525 Amps
@ 0.1 sec.
10 m7
Capacity
35 Ah @ 20 hr. rate to 1.75 volts per cell @ 77˚F (25˚C) Operating Temperature Range
(with temperature compensation)
Discharge: -40˚F (-40˚C) to +160˚F (71˚C), Charge: -10˚F (-23˚C) to +140˚F (60˚C)
Recommended Operating
Temperature Range
+74˚F (23˚C) to +80˚F (27˚C)
Equalization and Cycle Service
Charging and Current Limits
≤ 14 A, 14.5 - 14.9 volts
Self Discharge
Interstate batteries may be stored for up to six months at 77˚F (25˚C), and then
a freshening charge is required. For higher temperatures, the time interval will
be shorter.
Terminal
Insert, threaded female, ¼" – 20 (hardware included)
Constant Current Discharge Ratings – Amperes @ 77˚F (25˚C)
Operating Time to End Point Voltage (in hours)
End Point
Volts/Cell
9.60V
10.20V
10.50V
10.80V
11.10V
5 min
A
W
A
W
A
W
A
W
A
W
122
1297
108
1194
104
1175
100
1160
96
1139
10 min 15 min 30 min
89
946
81
901
77
876
73
853
69
825
63
666
56
623
53
599
50
576
46
550
38
403
36
399
35
397
34
396
33
393
1 hr
2 hr
3 hr
4 hr
5 hr
8 hr
10 hr
20 hr
19.8
229
18.6
216
18
209
17
203
17
200
12
134
11
128
10.8
125
10.5
122
10.2
122
8.5
98
8.3
96
8.1
93
7.9
91
7.6
90
6.6
76
6.4
75
6.3
73
6.2
72
6
71
5.4
63
5.3
62
5.3
61
5.1
60
5
60
3.8
44
3.8
43
3.7
43
3.6
42
3.5
42
3.5
40
3.4
39
3.3
39
3.3
38
3.1
37
1.9
21.7
1.8
21.1
1.8
20.9
1.8
20.7
1.7
20.1
Download