DCM0035 DCM0035 VALVE-REGULATED LEAD-ACID BATTERY FOR DEEP-CYCLE APPLICATIONS FEATURES • Robust plate for extended cycle life. • Computer-generated grid design optimized for high-power density. • Low-calcium grid alloy for reduced gas emissions and ease of recycling. • Flame-arresting, one-way pressure- relief vent for safety and long life. • UL-recognized component. • Multicell design for economy of installation and maintenance. • Case and cover available in standard polypropylene. • Thermally welded case-to-cover bond to eliminate leakage. • Removable handles. • Can be used in any orientation. Upright, side or end mounting recommended. • Absorbent Glass Mat (AGM) technol- ogy for efficient gas recombination of up to 99% and freedom from electrolyte maintenance. • Not restricted for air transport ­— complies with IATA/ICAO Special Provision A67. • Not restricted for surface transport ­— classified as nonhazardous material as related to DOT-CFR Title 49 parts 171-189. • Not restricted for water transport ­— classified as nonhazardous material per IMDG Amendment 27. • Longest cycle life available. • Manufactured by an ISO9001 certified facility. 12 Volts – 35 Ampere-Hour Capacity @ 20-Hour Rate Ampere-Hour Capacity to 1.75 Volts per Cell @ 77°F (25°C) 10.5 Volts per 12 Volt Battery 20 36 Approximate Discharge in Hours Amp-Hour Capacity Interstate Battery System of America, Inc. 12770 Merit Drive, Suite 1000 Dallas, TX 75251 Customer Service: 1-888-772-3600 Printed in the U.S.A. Rev. 12/06 MR 128782 © 2006 Interstate Battery System of America, Inc. interstatebatteries.com 10 33 5 26.5 1 18 DCM0035 7.68 (195) 5.16 (131) 7.13 (181) 6.14 (156) PT 1/4 - 20 THREAD PT DCM0035 – Specifications *All dimensions in inches and (millimeters). All dimensions are for reference only. Contact an Interstate representative for complete dimensional information. Cells Per Unit Voltage Per Unit Weight Electrolyte Max. Discharge Current Short Circuit Current Ohms Imped. 60 Hz 6 12 23.1 lbs. 10.5 kg Absorbed H2SO4 SG = 1.30 175 Amps 525 Amps @ 0.1 sec. 10 m7 Capacity 35 Ah @ 20 hr. rate to 1.75 volts per cell @ 77˚F (25˚C) Operating Temperature Range (with temperature compensation) Discharge: -40˚F (-40˚C) to +160˚F (71˚C), Charge: -10˚F (-23˚C) to +140˚F (60˚C) Recommended Operating Temperature Range +74˚F (23˚C) to +80˚F (27˚C) Equalization and Cycle Service Charging and Current Limits ≤ 14 A, 14.5 - 14.9 volts Self Discharge Interstate batteries may be stored for up to six months at 77˚F (25˚C), and then a freshening charge is required. For higher temperatures, the time interval will be shorter. Terminal Insert, threaded female, ¼" – 20 (hardware included) Constant Current Discharge Ratings – Amperes @ 77˚F (25˚C) Operating Time to End Point Voltage (in hours) End Point Volts/Cell 9.60V 10.20V 10.50V 10.80V 11.10V 5 min A W A W A W A W A W 122 1297 108 1194 104 1175 100 1160 96 1139 10 min 15 min 30 min 89 946 81 901 77 876 73 853 69 825 63 666 56 623 53 599 50 576 46 550 38 403 36 399 35 397 34 396 33 393 1 hr 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 20 hr 19.8 229 18.6 216 18 209 17 203 17 200 12 134 11 128 10.8 125 10.5 122 10.2 122 8.5 98 8.3 96 8.1 93 7.9 91 7.6 90 6.6 76 6.4 75 6.3 73 6.2 72 6 71 5.4 63 5.3 62 5.3 61 5.1 60 5 60 3.8 44 3.8 43 3.7 43 3.6 42 3.5 42 3.5 40 3.4 39 3.3 39 3.3 38 3.1 37 1.9 21.7 1.8 21.1 1.8 20.9 1.8 20.7 1.7 20.1