1.50 3.00 7.50 3.00 0.10 1.50 3.00 0.10 7.50 3.00 0.10 3.00 7.50 3.00 1.50 1" X 12" X 12' FASCIA BOARD ON 1" FLAT BAR 1.50 0.10 3.00 7.50 3.00 0.10 3.00 7.50 3.00 0.10 3.00 7.50 3.00 1.50 1" X 12" X 12' FASCIA BOARD ON 1" FLAT BAR 1.50 1" X 12" X 12' FASCIA BOARD ON 1" FLAT BAR 6.00 3.00 6.00 6.00 3.00 3.68 3.52 3.00 3.00 3.68 3.00 3.52 3.50 3.50 W2 7.00 3.50 W2 3.50 7.00 3.50 7.00 3.50 W1 D1 W1 DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS OFFICE OF THE DISTRICT ENGINEER 3.00 IN CASE OF DISCREPANCIES AS TO THE LAYOUT, DIMENSIONS, AND ELEVATION BETWEEN THE STRUCTURAL PLANS AND ARCHITECTURAL DRAWINGS, THE CONTRACTOR SHALL NOTIFY BOTH THE STRUCTURAL ENGINEER AND THE ARCHITECT. 4. ALL CONCRETE WORK SHALL BE DONE IN ACCORDANCE WITH THE ACI. 318 95 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE AND ALL STRUCTURAL STEEL WORK ACCORDING WITH AISC SPECIFICATION ( 9th EDITION ) IN SO FAR AS THEY DO NOT CONFLICT WITH THE LOCAL BUILDING CODE REQUIREMENT. 5. ACI REFERS TO AMERICAN CONCRETE INSTITUTE, AISC TO AMERICAN INSTITUTE OF STEEL CONSTRUCTION AND ASTM TO AMERICAN SOCIETY FOR TESTING MATERIALS. 6. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED. MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITION. L1/6 1. ALL CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH AT THE END OF TWENTY EIGHT ( 28) DAYS W/ CORRESPONDING MAXIMUM SIZE AGGREGATE & SLUMPS AS FOLLOW. 20mm 100mm BEAMS, SLABS 4000 psi ( 27.6 MPA ) 20mm 100mm SLAB ON FILL 3000 psi ( 27.6 MPA ) 20mm 100mm 4. TEMPERATURE BARS FOR SLAB SHALL BE GENERALLY PLACED NEAR THE FACE IN TENSION AND SHALL NOT BE LESS THAN 0.0025 x GROSS CROSS-SECTIONAL AREA ( Ag ) OF THE SLAB ( SEE SCHEDULE BELOW ) MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS SUSPENDED SLABS ------------------------------------------------------------------ 20mm SLAB ON GRADE ----------------------------------------------------------------------- 40mm WALLS ABOVE GRADE --------------------------------------------------------------- 25mm BEAM STIRRUPS AND COLUMN TIES ----------------------------------------------- 40mm WHERE CONCRETE IS EXPOSED TO EARTH BUT POURED AGAINST FORMS -------------------------------------------- 50mm WHERE CONCRETE IS DEPOSITED SCHEDULE OF MINIMUM SLAB REINFORCEMENT THICKNESS 100mm 125mm DIRECTLY AGAINST THE EARTH ----------------------------------------------------75mm CONCRETE SHALL BE DEPOSITED IN ITS FINAL POSITION WITHOUT SEGREGATION. RE-HANDLING OR PLACING SHALL BE DONE PREFERABLY WITH BUGGIES, BUCKETS OR WHEELBARROWS, NO CHUTES WILL BE ALLOWED EXCEPT TO TRANSFER CONCRETE FROM HOPPER TO BUGGIES, WHEELBARROWS OR BUCKETS IN WHICH CASE THEY SHALL NOT EXCEED SIX ( 6 ) METERS IN AGGREGATE LENGTH. 4. NO DEPOSITING OF CONCRETE SHALL BE ALLOWED WITHOUT THE USE OF VIBRATORS UNLESS AUTHORIZED IN WRITING BY THE DESIGNERS AND ONLY FOR UNUSUAL CONDITIONS WHERE VIBRATIONS IS EXTREMELY DIFFICULT TO ACCOMPLISH. 5. ALL ANCHOR BOLTS, DOWELS, AND OTHER INSERTS, SHALL BE PROPERLY POSITIONED & SECURED IN PLACE PRIOR TO PLACING OF CONCRETE. 6. ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN ( 7 ) CONSECUTIVE DAYS IMMEDIATELY AFTER POURING BY THE USE OF WET BURLAP, FOG SPRAYING, CURING COMPOUNDS OR OTHER APPROVED METHODS. 7. STRIPPING OF FORMS AND SHORES : FOUNDATION -------------------------------------------------------------------------- 24 hrs. SUSPENDED SLAB EXCEPT WHEN ----------------------------------------------- 8 days ADDITIONAL LOADS ARE IMPOSED WALLS --------------------------------------------------------------------------------- 24 days BEAMS --------------------------------------------------------------------------------- 24 days COLUMNS ----------------------------------------------------------------------------- 24 days MINIMUM TEMPERATURE BARS 10mm @ 250mm EACH WAY 10mm @ 225mm EACH WAY 150mm 10mm @ 185mm EACH WAY 175mm 10mm @ 150mm EACH WAY 200mm 10mm @ 140mm EACH WAY 5. UNLESS OTHERWISE NOTED IN THE PLANS ALL BEDDED SLABS SHALL BE REINFORCED WITH 10mm AT 250mm O.C EACH WAY TO CENTER OF SLAB AND CONSTRUCTION JOINTS FOR SAME SHALL NOT BE LESS THAN 3.65 METER APART 6. PROVIDE EXTRA REINFORCEMENTS FOR CORNER SLAB ( TWO ADJACENT DISCONTINUOUS EDGES ) AS SHOWN BELOW. 7. CONCRETE SLAB REINFORCEMENTS SHALL BE PROPERLY SUPPORTED WITH 10mm STEEL CHAIR OR APPROVED EQUIVALENT SPACED AT 1.0 METER ON CENTER BOTHWAYS DOWN INTO EDGE BEAM. EXTENDED 4- 12@ 1800 LONG TOP BARS BEND BARS MINIMUM OF 1200 ( 4'-0" ) INTO BARS. 1- 12 TOP & BOTTOM BARS 4- 12 BOTTOM BARS 400 0 0 0 6 DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS OFFICE OF THE DISTRICT ENGINEER 0 MINIMUM CONCRETE PROTECTION FOR REINFORCEMENTS SHALL BE 75mm CLEAR FOR CONCRETE DEPOSITED THE GROUND AND 50mm FOR CONCRETE DEPOSITED AGAINST A FORMWORK. 0 3. L2 L2/3 2D 2D L2/3 2D L2/5 L3 L3/3 2D L2/5 2-12mm SIDE BARS L3/3 2D L3/5 L3/6 WEB BARS BOTTOM BARS TOP BARS TABLE "A" TENSION BARS EMBEDMENT LENGTHS AND LAPPED SPLICES IN MILLIMETERS TABLE "B" COMPRESSION BARS EMBEDMENT LENGTHS AND LAPPED SPLICES IN MILLIMETERS fc' = 20.7MPa (3000psi) fc' = 20.7MPa (4000psi) BAR SIZE (DEFORMED) EMBEDMENT LAPPED EMBEDMENT LAPPED NOTE: ALL CONCRETE REINF. DETAIL SHOULD BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF ACI DETAILING MANUAL. fc' = 20.7MPa (3000psi) fc' = 20.7MPa (4000psi) BAR SIZE (DEFORMED) EMBEDMENT LAPPED EMBEDMENT LAPPED 10mm 300 300 300 300 10mm 225 300 200 300 12mm 300 300 300 300 12mm 275 300 250 300 16mm 300 400 300 400 16mm 350 400 325 400 20mm 400 550 350 500 20mm 450 500 475 500 25mm 600 800 550 750 25mm 550 625 550 625 28mm 750 1000 650 850 28mm 625 675 625 675 32mm 950 1300 850 1100 32mm 700 775 700 775 3. IF THE BEAM REINFORCING BARS END IN A WALL THE CLEAR DISTANCE FROM THE BAR TO THE FARTHER FACE OF THE WALL NOT BE LESS THAN 25mm. EMBEDMENT LENGTH SHALL BE AS SHOWN IN A TABLE "A" FOR TENSION BARS AND TABLE "B" FOR COMPRESSION BARS UNLESS SPECIFIED IN PLAN. TOP BAR SHALL NOT BE SPLICED WITHIN THE COLUMN. AT LEAST TWO STIRRUPS SHALL BE PROVIDED AT ALL SPLICES. 4. IF THERE ARE TWO OR MORE LAYERS OF REINFORCING BARS, USE 25mm BAR SEPARATORS SPACED AT 1.0m ON CENTER IN NO CASE SHALL THERE BE LESS THAN TWO ( 2 ) SEPARATORS BETWEEN TWO LAYERS OF BARS. 5. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS OR STEEL SHAPES BE AS SHOWN IN FIG. B - 2 UNLESS SPECIFIED ELSEWHERE. LAP SPACE LENGTH: AT ANY LEVEL NO MORE THAN ALTERNATE BARS SHOULD BE SPLICED MIN. DISTANCE BETWEEN TWO ADJACENT BARS SPLICES SHALL BE 600mm. 1- 12 EA. TOP & BOTTOM 38mm CLEAR 400 6 0 SLAB OPENING 6 2. FOOTINGS SHALL REST AT LEAST 15800mm BELOW NATURAL GRADE LINE UNLESS OTHERWISE INDICATED IN PLANS. NO FOOTING SHALL REST ON FILL. L1 FOR COL. BAR SPLICES SEE TABLE OF MIN. LAP SPLICE LENGTH OF COLUMN REINFORCEMENT (SPACING OF TIES ALONG THIS REGION SHALL NOT BE LESS THAN 100mm) 12 x 1000 LONG @ MID-DEPTH OF SLAB @ EACH CORNER THE CONTRACTOR SHALL SUBMIT THE SCHEDULE OF POURING AND THE LOCATION OF THE CONSTRUCTION JOINTS TO THE STRUCTURAL ENGINEER AT LEAST ( 4 ) DAYS PRIOR TO THE POURING FOR APPROVAL. FOOTINGS ARE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 96 kpa ( 2000 psf ). CONTRACTOR SHALL REPORT TO THE ENGINEER, IN WRITING, THE ACTUAL SOIL CONDITION UNCOVERED AND CONFIRM ACTUAL BEARING CAPACITY OF SOIL BEFORE DEPOSITING CONCRETE. LAP SPLICES ARE ALLOWED ONLY IN THIS PORTION JOINT HOOP SPACE @ "2Sh" WHEN THERE ARE BEAMS HAVING WIDTH OF AT LEAST ONE-HALF THE COLUMN WIDTH & DEPTHS NOT LESS THAN THREE QUARTERS OF THE DEEPEST BEAM THAT FRAME INTO FOUR SIDES OF THE COLUMN. ALL OTHER CONDITIONS USE HOOP @ "Sh" CENTER A 9. THE CONTRACTOR SHALL FURNISH AND MAINTAIN ADEQUATE FORMS AND SHORING UNTIL THE CONCRETE MEMBERS HAVE ATTAINED THEIR WORKING CONDITION AND STRENGTH 1. BOTTOM BAR IF SLABS ARE REINFORCED BOTHWAYS BARS ALONG THE SHORTER SPAN SHALL BE PLACED BELOW THOSE ALONG THE LONG SPAN AT THE CENTER AND OVER THE LONGER SPAN FOR REINFORCING BARS NEAR THE SUPPORTS. THE SPACING OF THE BARS AT THE COLUMN STRIPS SHALL NOT BE MORE THAN ONE AND A HALF ( 1 21 ) SLAB THICKNESS 3. 8. L2/5 TYPICAL BARS BENDING AND CUTTING DETAILS SHALL BE AS SHOWN IN FIG. B - 1 INTO TWO WAY SLAB EXTEND BARS UP TO BEAM SUPPORT OMIT TRIMMER BARS WHERE OPENING IS FRAMED BY BEAM 1- 12 EA. TOP & BOTTOM LAP SPLICE LENGTH: AT ANY LEVEL NO MORE THAN ALTERNATE BARS SHOULD BE SPLICED. MIN. DISTANCE BET. TWO ADJACENT BARS SPLICES SHALL BE 600mm. b see note WEB BARS see note MAIN REINFORCEMENT L/4 TOP BARS @ SUPPORT (CONT.) REQ'D. BOTT. BARS @ SUPPORT see note 0.025m SEPARATOR t or 1/4D 4000 psi ( 27.6 MPA ) TOP BAR 2. t 100mm BOTTOM BAR L1/5 L2 D 20mm L2/3 t 4000 psi ( 27.6 mpa ) TOP BAR L1/3 UNLESS , OTHERWISE NOTED IN PLANS, CAMBER ALL BEAMS AND GIRDER AT LEAST 6mm FOR EVERY 4.50m OF SPAN, EXCEPT CANTILEVERS FOR WHICH THE CAMBER SHALL BE AS NOTED IN PLANS OR AS ORDERED BY THE ENGINEER BUT IN NO CASE LESS THAN 20mm FOR EVERY 3.0m OF FREE SPAN. ht 2. ALL OTHERS, INCLUDING SUSPENDED SLABS COLUMNS 3. L1 1. 0.96 ALL RESULTS OF MATERIAL TESTING FOR CONCRETE, REINFORCING BARS & STRUCTURAL STEEL MUST BE NOTED & APPROVED BY THE STRUCTURAL DESIGNER. L1/3 THE DESIGN CONSULTANT SHALL BE HELD FULLY RESPONSIBLE FOR THE FAILURE OF THE FACILITY / IES / STRUCTURES DUE TO FAULTY DESIGN EXCEPT FOR THE CHANGES MADE WITHOUT THE CONFORMITY OF THE CONSULTANTS. SLEEVES FOR UTILITY PIPES MAX 1/5D PROVIDE 3-10 EXTRA STIRR. EACH SIDE OF SLEEVES D 9. 2. NOTE: PURSUANT TO SECTION 4 OF ANNEX "A" OF THE REVISED IMPLEMENTING RULES AND REGULATION OF R.A. 9184, APPROVAL BY AUTHORIZED DPWH OFFICIALS OF DETAILED ENGINEERING SURVEYS AND DESIGN UNDERTAKEN BY CONSULTANTS NEITHER DIMINISHES THE RESPONSIBILITY OF THE LATTER FOR THE TECHNICAL INTEGRITY OF THE SURVEYS AND DESIGN NOR TRANSFER ANY PART OF THAT RESPONSIBILITY TO THE APPROVING OFFICIALS. H CROSS-TIE WITHIN CENTER HALF OF "H" CONTRACTOR SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS, SILLS, STOOLS, EQUIPMENT'S AND MECHANICAL BASES THAT ARE REQUIRED BY THE ARCHITECTURAL, ELECTRICAL AND MECHANICAL DRAWINGS. ALL SLAB REINFORCEMENTS SHALL BE 20mm CLEAR MINIMUM FROM BOTTOM AND FROM TOP OF SLAB. UNLESS OTHERWISE SHOWN, REINFORCEMENT IN CONTINUOUS SLAB SHALL BE CUT AS FOLLOWS. n. 8. 4. mi SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEEL, MISCELLANEOUS IRON, PRE-CAST CONCRETE, ETC. SHALL BE SUBMITTED FOR ENGINEERS APPROVAL BEFORE FABRICATION. 3. d 10 7. 1. 2. PROVIDE EXTRA SETS OF TIES AT 100mm OC FOR TIED COLUMN REINFORCEMENT ABOVE AND BELOW BEAM - COLUMN CONNECTIONS FOR A DISTANCE FROM FACE OF CONNECTION EQUAL TO THE GREATER OF THE OVERALL THICKNESS OF COLUMN, 1 / 6 THE CLEAR HEIGHT OF COLUMN OR 450mm. COLUMN TIES SHALL BE PROTECTED EVERYWHERE BY A COVERING OF CONCRETE CAST MONOLITHICALLY WITH THE CORE WITH THE MINIMUM THICKNESS OF 40mm AND NOT LESS THAN 40 TIMES THE MAXIMUM SIZE OF COARSE AGGREGATE IN MILLIMETERS. WHERE COLUMNS CHANGE SIZE, VERTICAL REINFORCEMENTS SHALL BE OFFSET AT A SLOPE OF NOT MORE THAN 1 IN 6 AND EXTRA 10mm TIES AT 100mm SHALL BE PROVIDED THRU OUT THE OFFSET REGION UNLESS OTHERWISE INDICATED IN THE PLANS , LAP SPLICES FOR VERTICAL COLUMN REINFORCEMENT SHALL BE MADE WITHIN THE CENTER HALF OF COLUMN HEIGHT, AND THE SPLICE LENGTH SHALL NOT BE LESS THAN 40 BAR . WELDING OR APPROVED MECHANICAL DEVICES MAY BE USED PROVIDED THAT NOT MORE THAN ALTERNATE BARS ARE WELDED OR MECHANICALLY SPLICED AT ANY LEVEL AND THE VERTICAL DISTANCES BETWEEN THESE WELDS OR SPLICES OF ADJACENT BAR IS NOT LESS THAN 600mm 350mm MAX. H 3. C. BEAMS AND GIRDER -------------------------------------------fy = 275 mpa ( 40,000 psi ) D. NON-LOAD BEARING WALL PARTITION, BEDDED SLABS, FLOOR & ROOF SLABS, PARAPET, CATCH BASIN, SIDE WALK ------------------------- fy = 227.5 mpa ( 33,000 psi ) 2. ALL REINFORCING BARS SIZE 10mm OR LARGER SHALL BE DEFORMED IN ACCORDANCE WITH ASTM A 706. BARS SMALLER THAN 10mm MAY PLAIN. 3. SPLICES SHALL BE SECURELY WIRED TOGETHER & SHALL LAP OR EXTEND IN ACCORDANCE WITH TABLE A. & TABLE B ( TABLE OF LAP SPLICE & ANCHORAGE LENGTH ) UNLESS OTHERWISE SHOWN ON DRAWINGS, SPLICES SHALL BE STAGGERED WHENEVER POSSIBLE. 1. Sh IN REFERENCE TO THE DRAWING, SEE ARCHITECTURAL DRAWINGS FOR DEPRESSIONS IN FLOOR SLABS, OPENINGS IN THE WALLS AND SLABS, INTERIOR PARTITIONS, LOCATION OF DRAWING ETC. UNLESS OTHERWISE NOTED IN PLANS, THE STRENGTH OF REINFORCING BARS SHALL BE: A. FOOTINGS, FOOTING BEAMS AND GIRDERS -------------fy = 275 mpa ( 40,000 psi ) B. COLUMNS AND SHEAR WALLS ------------------------------- fy = 275 mpa ( 40,000 psi ) Sh 2. 1. JT. REINF. IN THE INTERPRETATION OF THE DRAWING, INDICATED DIMENSIONS SHALL GOVERN AND DISTANCES AND SIZES SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. D D COLUMN TIES AS D D CONF. REINF. JOINT REINF.CONF. REINF. PER SCHEDULE CONF. REINF.JOINT REINF. CONF. REINF. 1. SPLICE BOTTOM BARS AT MID SPAN EXTRA TOP BARS @ SUPPORT 6. WHEN A BEAM CROSSES A GIRDER, REST BEAM ON TOP OF GIRDER BARS, BEAM REINFORCING BAR SHALL BE SYMMETRICAL ABOUT CENTER LINE WHENEVER POSSIBLE. 7. GENERALLY NO SPLICES SHALL BE PERMITTED AT POINTS WHERE CRITICAL BENDING STRESSES OCCUR, SPLICES WHERE NO PERMITTED SHALL BE INDICATED IN THE TABLE "A" AND "B" WELDED SPLICES SHALL BE DEVELOP IN TENSION AT LEAST 125% OF THE SPECIFIED YIELD STRENGTH OF THE BAR. NOT MORE THAN 50% OF THE BARS AT ANY ONE SECTION IS ALLOWED TO BE SPLICED THEREIN. 1.60m 1.90m 2.20m 14.0 200 200 200 111- 10 10 12 111- 10 10 10 6mm @ 200mm 6mm @ 200mm 6mm @ 200mm 2.10m 2.40m 2.70m 2.50m 2.90m 3.10m 17.0 250 250 250 111- 12 12 16 111- 10 10 12 6mm @ 200mm 6mm @ 200mm 10mm @ 200mm 3.00m 3.30m 3.60m 3.40m 3.70m 4.00m 20.0 300 300 300 1 - 16 1 - 16 1 - 20 111- 12 12 12 10mm @ 200mm 10mm @ 200mm 10mm @ 200mm 550 = = 275 MPa (40,000 psi) 230 MPa (33,000 psi) fy = 248MPa (36,000 psi) fy = 248MPa (36,000 psi) fm' = 3.45 MPa (500psi) b) Fv = 69MPa(10,000 psi) t/3 30 BAR DIA. (min.) 40 t t/3 50 500 20.70 MPa ( 3,000 psi) t/3 1.20m 1.50m 1.80m 30 BAR DIA. (min.) D STIRRUPS = WHERE A CONSTRUCTION JOINT IS TO BE MADE, THE SURFACE OF CONCRETE SHALL BE CLEANED AND ALL LAITANCE AND STANDING WATER REMOVED. SHEAR KEY SHALL BE PROVIDED AT THE JOINT. D/3 TOP 1 fc' 250 BOTTOM 600 (MIN.) HEIGHT OF LINTEL (mm) VARIES LINTELS IN BLOCK WALLS 500 550 REINFORCING BARS SHALL HAVE 25mm CLEAR CONCRETE COVER FROM FACE OF WALL EXCEPT FOR WALLS IN CONTACT WITH THE GROUND WHERE A MINIMUM OF 60mm SHALL BE PROVIDED, AND FOR EXPOSED FACES FORMED WALLS WHERE THE MINIMUM SHALL BE 50mm CLEAR. CARRY VERTICAL BARS AT LEAST 60mm ABOVE FLOOR LEVEL TO PROVIDE FOR SPLICES WHEN NECESSARY STOP AT 50mm BELOW TOP SLAB OR SOLID BAND WHERE THE WALL ENDS VERTICAL AND HORIZONTAL BARS SHALL BE SPLICED BY LAPPING A DISTANCE EQUAL TO 30 AND WIRED SECURELY WITH 16 G.I. WIRE PROVIDED THAT SPLICES IN ADJACENT BARS ARE STAGGERED AT LEAST 1.50M OC UNLESS OTHERWISE NOTED IN THE PLANS, ALL OPENINGS IN WALLS 250mm OR THICKER SHALL BE REINFORCED AROUND WITH 2 - 20mm BARS FOR 225mm, 200mm, 175mm, 150mm, USE 2 - 16mm . FOR 125mm AND 100mm WALLS, USE 2 - 12mm BARS. ALL WALLS SPANNING SHALL HAVE VERTICAL REINFORCEMENT BENT TO A U - FORM LIKE STIRRUPS AND SPACED ACCORDING TO THE SCHEDULE UNLESS OTHERWISE NOTED ( SEE FIG. 1 ) D/3 D/3 2. 3. CLEAR TOTAL MIN. SPAN LENGTH fc' ("L") (L + 0.40m) (MPa) 2. DESIGN STRESS A. CONCRETE COMPRESSIVE STRENGTH AT 28 DAYS B REINFORCING BARS a) FOR BARS 16mm AND GREATER fy b) FOR BARS LESS THAN 16mm fy C STRUCTURAL STEEL, ASTM - A36 FOR TRUSSES, BRACINGS, AND STRUTS D PURLINS COLD FORMED LIGHT CAGE SHAPES E MASONRY UNIT (CHB) NON - LOADING BEARING CHB WALLS F WELDS - USED E - 60xx ELECTRODE G STRUCTURAL BOLTS, ASTM - A307 a) Ft = 96.60 MPa (14,000 psi) ALL WALLS SHALL BE REINFORCED ACCORDING TO THE FOLLOWING SCHEDULE OF WALL REINFORCEMENT UNLESS OTHERWISE INDICATED IN THE PLANS. 400 (DOWEL) 400 (DOWEL) SCHEDULE OF CONCRETE HOLLOW BLOCK AND CERAMIC BLOCK REINFORCEMENT 400 1. 2. 250 400 DOWEL 300 (TYP.) 400 DOWEL 1. 2. 3. 4. 5. USE E70xx ELECTRODES FOR ALL MEMBERS WELDED. WELDS SHALL DEVELOP THE FULL STRENGTH OF MEMBERS JOINED UNLESS OTHERWISE SHOWN OR DETAILED IN THE DRAWINGS. STRUCTURAL STEEL TO BE USED FOR FABRICATION AND ERECTION OF THIS STRUCTURE SHALL COMPLY WITH ALL THE PERTINENT PROVISION OF AISC SPECIFICATION OR DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDING LATEST EDITION. ALL STRUCTURAL STEEL SHAPES SHALL CONFORM TO ASTM A36 STRUCTURAL STEEL UNLESS OTHERWISE INDICATED. ALL WELDED CONNECTIONS SHALL DEVELOP THE FULL STRENGTH OF THE MEMBERS CONNECTED. UNLESS OTHERWISE SPECIFIED ALL WELDING RODS SHALL CONFORM AWS E60 ELECTRODES. ALL BOLTS USED UNLESS OTHERWISE SPECIFIED SHALL BE ASTM A 307 BOLTS. 38mm CLEAR 400 LOADINGS A. DEAD LOAD CONCRETE STEEL 150mm THK. CHB WALL 100mm THK. CHB WALL - 23.56 KN / m3 76.93 KN / M3 2.73 kPA 2.11 kPA - 1.00 kPA 3 B. LIVE LOAD ROOF L 4db or 65mm DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS OFFICE OF THE DISTRICT ENGINEER D = FOR BEAM 2t = FOR SLAB 30 BAR DIA. (min.) THE DESIGN CONSULTANT SHALL BE HELD FULLY RESPONSIBLE FOR THE FAILURE OF THE FACILITY / IES / STRUCTURES DUE TO FAULTY DESIGN EXCEPT FOR THE CHANGES MADE WITHOUT THE CONFORMITY OF THE CONSULTANTS. WHERE : W = TOTAL DEAD LOAD T = NATURAL PERIOD = Ct (hn) ; WHERE : C = NUMERICAL COEFFICIENT h = BUILDING HEIGHT I = IMPORTANCE FACTOR = 1.50 R = NUMERICAL FACTOR = 8.50 SEISMIC COEFFICIENT Cv = 0.44Nv Ca = 0.64N NEAR SOURCE FACTOR ( 10km ) Nv = 1.20 Na = 1.00 Z = SEISMIC ZONE = 0.40 ( ZONE 4 ) S = SOIL TYPE = D L 12db NOTE: PURSUANT TO SECTION 4 OF ANNEX "A" OF THE REVISED IMPLEMENTING RULES AND REGULATION OF R.A. 9184, APPROVAL BY AUTHORIZED DPWH OFFICIALS OF DETAILED ENGINEERING SURVEYS AND DESIGN UNDERTAKEN BY CONSULTANTS NEITHER DIMINISHES THE RESPONSIBILITY OF THE LATTER FOR THE TECHNICAL INTEGRITY OF THE SURVEYS AND DESIGN NOR TRANSFER ANY PART OF THAT RESPONSIBILITY TO THE APPROVING OFFICIALS. db VERIFY DEPRESSION D = FOR BEAM t = FOR SLAB 30 BAR DIA. 30 BAR DIA (min.) (min.) db 200(mm) 6 C. 200(mm) WIND LOAD ( NSCP 2010 ) BASIC WIND VELOCITY, V = 250 KPH P = qh [(GCpf) - (GCpi)] (DESIGN WIND PRESSURE) WHERE: qh = VELOCITY PRESSURE, kPA GCpf = EXTERNAL PRESSURE COEFFICIENT GCpi = INTERNAL PRESSURE COEFFICIENT D. SEISMIC LOAD ( NSCP 2010 ) V = [( Cvl / RT ) W] ( DESIGN BASE SHEAR ) Vmax = ( 2.50CAL / R ) W Vmin = 0.11 CalW Vmin = ( 0.80 ZNvl / R ) W (ZONE 4) db D L L1 D 1. L 2 ALL REINFORCEMENT SHALL BE BENT COLD UNLESS OTHERWISE PERMITTED BY THE STRUCTURAL ENGINEER. REINFORCEMENT PARTIALLY EMBEDDED IN CONCRETE SHALL NOT BE FILLED BENT, EXCEPT AS SHOWN IN THE DESIGN DRAWINGS OR PERMITTED BY THE STRUCTURAL ENGINEER. TIES AND CLOSE STIRRUPS MUST BE D + 2db 1 D 1.25 NOTES OF STIRRUPS: db 250 400 DOWEL 400 DOWEL A. ALL EMBEDDED PIPES FOR UTILITIES, ETC. THAT PASS THRU BEAMS SHALL NOT EXCEED 100mm IN OR 1 / 3 BEAM DEPTH WHICHEVER IS LESS, UNLESS OTHERWISE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER B. NO PIPES SHALL BE ALLOWED TO PASS THRU BEAMS VERTICALLY. C. NO PIPES SHALL BE EMBEDDED IN COLUMNS. 300 (TYP) 400 200 (DOWEL) 2. UNLESS OTHERWISE SHOWN IN PLANS ALL CONCRETE HOLLOW BLOCKS AND CERAMIC BLOCKS SHALL BE REINFORCED AS SHOWN IN THE SCHEDULE OF CONCRETE HOLLOW BLOCKS AND CERAMIC BLOCK REINFORCEMENT PROVIDE 150mm X 300mm STIFFENER COLUMN REINFORCED WITH 4 -12mm WITH 6mm TIES AT 150mm ON CENTER WHERE CONCRETE HOLLOW BLOCK TERMINATES AND AT EVERY 3.00m LENGTH OF CONCRETE HOLLOW BLOCK WALLS UNLESS NOTED IN STRUCTURAL PLANS. 400 DOWEL 1. VERIFY ARCHITECTURAL 1. 0.20 0.20 0.20 L/4 L RCB-1 L/4 @ SUPPORT 10mm TEMP.BARS @0.20m OC, BOTHWAYS 12mm CUT BARS @0.20m OC, BOTHWAYS @ MIDSPAN L/5 L/5 7 - 16mm DOWEL, 1.00m EXTENDED L/4 0.40 12mm BENT UP BARS @0.20m OC, BOTHWAYS PLAN 10mm TEMP.BARS @0.20m OC, BOTHWAYS 3.50 12mm CUTBARS @0.20m OC, BOTHWAYS L L/5 0.20 L/5 @ SUPPORT @ MIDSPAN L/4 L/4 0.125 0.20 0.20 0.20 0.20 0.20 0.20 0.30 0.30 0.20 RCB-1 12mm BENTBARS @0.20m OC, BOTHWAYS L/2 L M S RCB-1 0.20 0.40 0.20 L/4 0.20 0.20 0.20 0.20 L/4 L L/2 SECTION L/4 RCB-1 L/2 L/4 0.10 L/4 DESIGN CRITERIA: RCB-1 0.05 0.20 0.20 0.05 0.20 12mm BENTBARS @0.20m OC, BOTHWAYS RCB-1 10mm CUTBARS 10mm TEMP.BARS @0.20m O.C. BOTHWAYS @0.10m OC, BOTHWAYS fy = 230 MPa 4. ASSUMED ALLOWABLE BEARING CAPACITY Y = 100KPa NOTE: WATER TABLE IS 1500 BELOW GROUND LEVEL. SLOPE DIRECTION OF FLOOR DRAIN 0.35 10mm BASE BAR SPACED @ 0.20mm O.C. 1.20 0.25 i. LIVE LOAD ________________________1000Pa ii. ALLOWABLE STRESSER 1. CONCRETE a. FOR FOOTING, BEAMS AND SLABS fc" = 20 MPa 2. CONCRETE MASONRY UNITS (LOAD BEARING CHB) fm' = 6.90 MPa, fM = 2.41 MPa 3. REINFORCING STEEL BARS L 3.52 6.00 3.00 3.00 S-1 S-1 3.68 3.52 3.00 0.075 3.68 3.50 3.00 3.50 3.00 6.00 3.00 3.50 6.00 7.00 S-1 0.075 1.20 0.30 3.50 3.50 7.00 3.50 S-1 0 7.00 .5 0 S-1 0.25 1.20 DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS OFFICE OF THE DISTRICT ENGINEER 0.075 GENERAL ELECTRICAL NOTES: ELECTRICAL LEGEND: SYMBOL TYPICAL SCHEDULE OF LOAD OUTLET VOLTS WATTS AMPERE PER CIRCUIT PROTECTION WIRE SIZE CONDUIT DISTRIBUTION BOARD / PANEL CIRCUIT HOMERUN LIGHT OUTLET WALL LAMP M KILOWATTHOUR METER CIRCUIT BREAKER USE: AMP. MOLDED CIRCUIT BREAKER, 2-WIRE WITH 4 BRANCH CIRCUIT. 6.00 3.00 3.50 7.00 3.50 3.00 x 2400mm LENGTH DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS OFFICE OF THE DISTRICT ENGINEER 250 VOLTS