FOR REFERENCE ONLY This drawing is representative of the documentation requirements of Schedule 1. The content should not be relied upon as accurate for another building project. DRAWING SCHEDULE Any specific manufacturer, product, material or components shown within this set of drawings has been included for example purposes only. A01 - Cover Page A02 - Site Plan A03 - Floor Plan, Roof Plan & Elevations A04 - Slab Plan, Roof Framing & Bracing Plan, Section & Detail A05 - Connection Details Site Information Land Title Reference: ..... (Certificate folio and volume) Wind Classification: N3 Site classification to AS 4055-2006 Soil Classification: N/A Not applicable for this example. May be required for other Class 10 designs Climate Zone: N/A Unless containing a conditioned space or for snow loading requirements (www.abcb.gov.au map) BAL Level: N/A No areas of bushfire prone vegetation >1ha within 100m of the building Alpine Area: N/A BCA Figure 3.7.5.2 Corrosion Environment: N/A For steel subject to the influence of salt water, breaking surf or heavy industrial areas, refer to BCA section 3.4.2.2 & BCA Table 3.4.4.2. Cladding and fixings to manufacturer's recommendations Other Hazards: N/A High wind, earthquake, flooding, landslip, dispersive soils, sand dunes, mine subsidence, landfill, snow & ice or other relevant factors Floor Area: 48m2 BP01 - Bushfire Protection Plan (Provided for reference only - example building is not in a Bushfire-Prone Area) Accredited Building Designer / Architect Proposed Class 10a garage @: 10 Example Street, TASMANIA Rev. Amendment Date Designer / Architect name ..... Accreditation number ..... Accredited Practitioner: Owner / Client: Drawing Title: Date: Status: Name Address Phone number Building Standards & Occupational Licensing Cover Page 01/10/2014 INFORMATION Scale: Drawing No.: NTS @ A3 A01 Project: Class 10a (Garage) Example 10 Example Street, TASMANIA (1 of 5) Rev - LEGEND & NOTES FOR REFERENCE ONLY This drawing is representative of the documentation requirements of Schedule 1. The content should not be relied upon as accurate for another building project. 5,500 Boundary to garage 7,500 Proposed garage length Manhole DP. Downpipe Protection Work (Section 121 of the Building Act) If excavation is to a level below that of the adjoining owner's footings, along the title boundary or within 3 metres of a building belonging to an adjoining owner, the builder must (as a miniumum) provide and maintain a guard to supervise the excavation. Adjoining owner to be notified using Form 6 (Building and Protection Work Notice) by the Building Surveyor. ADJACENT GARAGE Stormwater main is located 1,100mm below ground level at manhole. MH. Sewer. Stormwater. X DP. End of AG drain. Approximately 150mm of compacted FCR required to create a level base for garage. Ensure land falls away from footings in all directions. PROPOSED GARAGE DP. 90Ø UPVC below ground stormwater pipe connected into stormwater main within easement. AG drain to discharge well clear of footings. Fall Stormwater main from boundary. 2,000 BOUNDARY Sewer main from boundary. Fall 650 deep 100Ø AG drain with filter sock installed at time of footing construction. BOUNDARY 3.0m DRAINAGE EASEMENT MH. BOUNDARY 1,500 6,400 Proposed garage width BOUNDARY MH. 750 1,400 3,000 Easement width. ADJACENT DWELLING SITE PLAN scale 1:200 Rev. Amendment Date Owner / Client: Drawing Title: Date: Status: Name Address Phone number Building Standards & Occupational Licensing Site Plan 01/10/2014 INFORMATION Project: Scale: Drawing No.: 1:200 @ A3 A02 No rt h Accredited Practitioner: Class 10a (Garage) Example 10 Example Street, TASMANIA (2 of 5) Rev - LEGEND & NOTES FOR REFERENCE ONLY This drawing is representative of the documentation requirements of Schedule 1. The content should not be relied upon as accurate for another building project. Conc. Concrete floor finish DP. 01 - Colorbond custom orb roof sheeting at 11º pitch. One and a half corrugation side lap (typical). Colour: Basalt. Refer to A02 Site Plan for stormwater connection. 7,500 6,400 DOUBLE GARAGE Wall Cladding Fixing Fall Roof and wall cladding installed to comply with AS1562 and manufacturer's instructions. Window / Glazing 02 - Conc. S.09.12 Folded colorbond ridge flashing. Fall Roller door 2700W x 2200H - Single glazed 5mm toughened glass sliding window - 900H x 1200H, sill @ 900 AFL. - Powdercoated aluminium frame. Colour: Basalt. 1,105 1,200 Colorbond custom orb roof sheeting crest fixed at every second crest with 12-14 x 50mm Metal Teks. Colour: Basalt. Colorbond Trimwall wall cladding pan fixed in every bay with side lap fasteners to crests as per Lysaght installation details. Fix with 10-16 x 16mm Metal Teks. Colour: Dune. Roller door 2700W x 2200H 04 - Roof Cladding Fixing Stramit Hi-Front Quad Gutters in colorbond. Colour: Basalt. 90Ø DP. 90Ø DP. Downpipe 90Ø DP. 820 90Ø DP. 03 - FLOOR PLAN A A04 scale 1:100 2,400 DP. 3,125 Overall height scale 1:100 Eaves A A04 ROOF PLAN Colorbond roller doors. Colour: Basalt. FL. ELEVATION 01 ELEVATION 02 scale 1:100 scale 1:100 Powdercoated aluminium sliding window. Colorbond folded head and sill flashings to glazing manufacturer's approval. 2040 x 820 Colorbond door and frame kit. Colour: Basalt. Colorbond folded head flashing. FL. S. DP. ELEVATION 03 Date DP. Colorbond downpipes. Colour: Dune. Vertical colorbond Trimwall cladding. Colour: Dune. ELEVATION 04 scale 1:100 Rev. Amendment F. 1,200 900 DP. 2,400 Eaves scale 1:100 Accredited Practitioner: Owner / Client: Drawing Title: Date: Status: Name Address Phone number Building Standards & Occupational Licensing Floor Plan, Roof Plan & Elevations 01/10/2014 INFORMATION Project: Scale: Drawing No.: 1:100 @ A3 A03 Class 10a (Garage) Example 10 Example Street, TASMANIA (3 of 5) Rev - FOR REFERENCE ONLY LEGEND & NOTES Slab / Footings For pre-fabricated steel buildings this drawing is often provided by the supplier, in which case there is no requirement for the Designer to reproduce the information. This drawing is representative of the documentation requirements of Schedule 1. The content should not be relied upon as accurate for another building project. EB1 7,440 Overall slab 2 3 1 2 3 3,628 B S S A04 g. e. e. c. 05 A05 02 A05 b. 03 A05 b. . br br . EB1 a. e. a. a. br. 753 A A04 Framing and Bracing Roof pitch: Eaves height: e. 951 e. f. 04 A05 a. A A04 ROOF FRAMING & BRACING PLAN scale 1:100 scale 1:100 50mm 25MPa 20mm nominal Steel trowel All concrete shall be cured for 7 days. The Engineer's approval of the proposed method of curing shall be obtained before pouring. 11º 2400mm a. C150 12 column b. C100 12 column c. C150 12 portal rafter with 50 x 50 x 2.5 collar tie d. C100 10 door head e. TS6175 roof battens @ 1200 max. crs. 600mm overlap at central portal with 2 - #14 Tek screws at either end. f. C100 15 fascia purlin g. TS6175 side wall battens @ 900 crs 600mm overlap at central column with 2 - #14 Tek screws at either end. b. a. 01 A05 SLAB PLAN e. d. (door head) b. C 06 A05 e. g. C Concrete slump: Concrete strength: Aggregate size: Finish: a. g. a. 3,034 S = sawcut at 24 hours. e. d. (door head) br. B f. . br c. Provide sloping rebates within slab for weather protection at base of all garage doors. a. br . 3,034 100mm thick concrete slab: SL82 top, 30mm cover. 0.2 mm Fortecon vapour barrier. 50mm compacted sand. EB1 S Z a. A S EB1 6,340 Overall slab br. EB1 A Footings shall be founded on approved material having a bearing capacity of 100kPA. 3,628 c. 1 Edge beam 1 (as per detail Z) Founding depth: 400mm Founding material: Dense sand ASSUMED TO BE CLASS 'M' (If soil conditions are not as above an alternative footing / slab design from an Engineer is required) br. 30 x 1.0 tensioned galv. strap fixed to each member with 14 x 25 tophat screws C B Collar tie. 11 degree roof pitch Min. 50mm clearance to ground from cladding. g. a. g. 100 thick slab, SL82 top. EB1 Fall Hi-tensile Bolts Compacted FCR to create level base. Natural ground line dotted. EB1 4-L11 TM to bottom. Vapour barrier (0.2mm Fortecon) shown dotted. 300 Bolts, nuts and washers shall comply with AS 1252. 8.8/S bolts installed to comply with AS 1511 and tensioned to produce the following shank tensions: M12 - 50kN M16 - 90kN Self-Drilling Screws Must comply with AS 3566. SECTION A scale 1:100 All steel to comply with AS 4100 Steel Structures and AS/NZS 4600 Cold-Formed Steel Structures. Steel framing to be manufactured from Hi-tensile hot dip zinc coated steel conforming to AS 1397 and installed as per manufacturer's instructions. 50mm compacted sand. . br g. FL. 150 x 100 x 100 x 4mm Duragal base plate. 2 x M12 8.8S bolts to column. 2 x 12mm dia. x 80mm Dynabolts to slab. 400 g. 100 2,400 Eaves Structural Steel a. A Z EDGE BEAM DETAIL scale 1:20 Rev. Amendment Date Accredited Practitioner: Owner / Client: Drawing Title: Date: Status: Name Address Phone number Building Standards & Occupational Licensing Slab Plan, Roof Framing & Bracing Plan, Section & Detail 01/10/2014 INFORMATION Project: Scale: Drawing No.: 1:100,1:20 @ A3 A04 Class 10a (Garage) Example 10 Example Street, TASMANIA (4 of 5) Rev - FOR REFERENCE ONLY LEGEND & NOTES For pre-fabricated steel buildings this drawing is often provided by the supplier, in which case there is no requirement for the Designer to reproduce the information. This drawing is representative of the documentation requirements of Schedule 1. The content should not be relied upon as accurate for another building project. C B Fascia cleat: 3 x #14 Tek screws to 'a'. 2 x #14 Tek screws to 'f'. e. 1 e. Custom orb roof cladding. Folded colorbond ridge flashing. c. c. e. f. c. Colorbond gable end flashing. c. a. C150 12 column b. C100 12 column c. C150 12 portal rafter with 50 x 50 x 2.5 collar tie d. C100 10 door head e. TS6175 roof battens @ 1200 max. crs. 600mm overlap at central portal with 2 - #14 Tek screws at either end. f. C100 15 fascia purlin g. TS6175 side wall battens @ 900 crs 600mm overlap at central column with 2 - #14 Tek screws at either end. 4 x M16 bolts to rafter 'c'. g. 2.4mm G450 galvanised folded connector plate: 4 x M16 bolts to each rafter 'c'. 3 x M16 bolts to column 'a'. g. a. br. 30 x 1.0 tensioned galv. strap fixed to each member with 14 x 25 tophat screws a. a. 01 PORTAL FRAME END BAY EAVE DETAIL 02 PORTAL FRAME END BAY RIDGE DETAIL scale 1:20 03 GABLE END RIDGE DETAIL scale 1:20 C scale 1:20 B Fascia cleat: 3 x #14 Tek screws to 'a'. 2 x # 14 Tek screws to 'f'. e. B e. e. Folded colorbond ridge flashing. Folded colorbond ridge flashing. c. f. 2.4mm G450 galvanised folded connector plate: 6 x M16 bolts to column 'a'. 4 x M16 bolts to rafter 'c'. c. c. c. 2.4mm G450 galvanised folded connector plate: 4 x M16 bolts to each rafter 'c'. g. a. 2200 d. 04 PORTAL FRAME EAVE DETAIL 05 PORTAL FRAME RIDGE DETAIL scale 1:20 Rev. Amendment c. Date d. a. a. 2.4mm G450 galvanised folded connector plate: 4 x M16 bolts to each rafter 'c'. 2 x M16 bolts to column 'a' (also passing thru' rafters). 100 x 50 x 50 x 2.4mm angle cleat. 4 x #14 Tek screws. 06 PORTAL FRAME END BAY DOOR HEAD DETAIL scale 1:20 scale 1:20 Accredited Practitioner: Owner / Client: Drawing Title: Date: Status: Name Address Phone number Building Standards & Occupational Licensing Connection Details 01/10/2014 INFORMATION Project: Scale: Drawing No.: 1:20 @ A3 A05 Class 10a (Garage) Example 10 Example Street, TASMANIA (5 of 5) Rev - FOR REFERENCE ONLY This drawing is representative of the documentation requirements of Schedule 1. The content should not be relied upon as accurate for another building project. This drawing has been included as an example of how to present the relevant AS 3959 requirements for a BAL-29 building. Note that the example garage is not deemed to be within a Bushfire-Prone area, and as such the information on this drawing has not been applied to drawings A01 through A05. Additional information required for a Building Application: BUSHFIRE RELATED NOTES (BAL-29) 1. BAL Assessment / Report by an Accredited Bushfire Assessor. To comply with Section 7 of AS3959-2009. Including, but not limited to the following: 2. Bushfire Hazard Management Plan prepared by an Accredited Bushfire Assessor. Alternatively (for Building Applications only) a competent Designer / Architect may complete their own BAL Assessment and BHMP using the 'Bushfire Attack Level Assessment Report' as published by the Australian Institute of Building Surveyors. Access and Water provisions are not required for a Class 10 building. For current information and further details on the above, refer to Department of Justice website: http://www.justice.tas.gov.au/building/regulation/building_in_hazardous/bushfire-prone_areas Joints All joints in the external surface material of walls shall be covered, sealed, overlapped, backed or butt-jointed to prevent gaps greater than 3mm. Vents Vents in external walls shall be screened with aluminium mesh with a maximum aperture of 2mm, except where the vents have an aperture less than 3mm. Windows / Glazing Window frame and supporting frame shall be powdercoated aluminium with toughened glass minimum 5mm thickness. Openable portions of windows to be screened internally or externally with screens as described below. Screens for Windows Aluminium screens within powdercoated aluminium frames must have a maximum aperture of 2mm. Gaps between the perimeter of the screen assembly and the window frame shall not exceed 3mm. Gable Gable External walls - Colorbond steel wall cladding with sarking on the outside of the steel framed wall Roof Roof sheeting to be colorbond (ie. non-combustible). The roof / wall junction shall be sealed between the top of the wall and underside of the roof, to prevent openings greater than 3mm. Roof ventilation openings, such as gable and roof vents, shall be fitted with aluminium ember guards with a maximum aperture of 2mm. Vehicle access doors - Colorbond roller door; guide tracks to have a maximum gap no greater than 3mm - Raven RP57 (or equivalent) nylon brush fitted at top to be in contact with the door - No ventilation slots are permissable Sheet roof to be fully sarked. The sarking shall: a) be located on top of the roof framing, except that the roof battens may be fixed above the sarking; b) cover the entire roof area including ridges and hips; and c) extend into the gutters. Window - Toughened glass min. 5mm thickness - Screen (internal or external) - See notes in schedule on RHS of drawing Any gaps greater than 3mm (such as under corrugations or ribs of sheet roofing and between roof components) sealed at the fascia or wall line and at hips and ridges by (i) aluminium mesh with maximum aperture of 2mm; or (ii) mineral wool; or (iii) other non-combustible material; or (iv) a combination of any of the above items. Personnel door - Colorbond metal clad door (non-combustible) - Metal door frame - Door shall be tight fitting to the door frame - Raven RP2b (or equal) door bottom seal Roof Penetrations Roof penetrations, including roof ventilators, aerials, and supports for solar collectors shall be adequately sealed at the roof to prevent gaps greater than 3mm. The material used for sealing shall be non-combustible. BUSHFIRE PROTECTION PLAN scale 1:100 Openings in roof ventilators or vent pipes shall be fitted with aluminium ember guards with a maximum aperture of 2mm. Rev. Amendment Date Accredited Practitioner: Owner / Client: Drawing Title: Date: Status: Name Address Phone number Building Standards & Occupational Licensing Bushfire Protection Plan BAL-29 Construction 01/10/2014 INFORMATION Project: Scale: Drawing No.: Rev 1:100 @ A3 BP01 - Class 10a (Garage) Example 10 Example Street, TASMANIA