Description
Transducer -1 to 20 BAR (-14.5 to 290 PSI) with 1/4in NTP male fitting
Transducer -1 to 20 BAR (-14.5 to 290 PSI) with 7/16in 20UNF(F)
Transducer -1 to 65 BAR (-14.5 to 940 PSI) with 1/4in NTP male fitting
Transducer -1 to 65 BAR (-14.5 to 940 PSI) with 7/16in 20UNF(F)
Transducer 0 to 125 BAR (0 to 1810 PSI) with 1/4in NTP male fitting
Part Number
PR0160
PR0161
PR0162
PR0163
PR0164
V1.3 www.resourcedm.com
Parameter
Pressure Range
Pressure Type
Overload
Burst Pressure
Accuracy (Linearity Hysteresis
Repeatability)
Stability
Working Temperature
Storage Temperature
Temperature Compensation
Thermal effect on zero
Thermal effect on span
Medium compatible
Electronic wire
Output
Power supply
Short Circuit protected
Overvoltage protection
Insulate resistance
Electronic connection
Pressure connect port
Response time
Certificate approving
EMC standard
Water proof
Weight
Compatible Refrigerants
Spec
-1-20 bar, -1-65 bar, 0-125 bar
Gauge pressure, Absolute pressure
200% F.S
300% F.S
≤ ±0.5%F.S
≤ ±1%F.S
Optional
0.5%F.S ± 0.05%
-40°C~95°C
-40°C~125°C
-10°C~60°C (standard)
+/- 0.05%
+/- 0.005%
Compatible with 304/316 Stainless steel
2/ 3 Wires
4~20mA
12~36V DC
Yes
45 V DC
>100M Ω @50V
Packard 3 pin connector with 2.0m cable
¼” NPT male, 7/16in 20UNF(F)
≤10ms
CE Certificate
Electromagnetic radiation: EN50081-1/-2
Electromagnetic susceptibility: EN50082-2
IP67
Net weight 0.2Kg
Full packaging weight 0.35Kg (includes 2.0m cable
R12 , R21 , R22 , R31 , R32 , R113 , R114 , R154a ,
R404a , R407a , R407c, R410a, R502, R507, R744.
V1.3 www.resourcedm.com
The specifications of the product detailed in this document may change without notice. RDM Ltd shall not be liable for errors or omissions, for incidental or consequential damages, directly or indirectly, in connection with the furnishing, performance or misuse of this product or document.
Revision
1.0
1.1
1.2
1.3
Date
16/01/2014
05/03/2014
01/10/2014
10/08/2015
Changes
First Release
US address details updated
Refrigerant table added
Image added of male fitting transducer
V1.3 www.resourcedm.com