Pilot devices, 22 mm Catalogue 1SFC 261001-EN Edition 4 December 2000 Supersedes Catalogue 1SFC 261001-EN Edition 3 January 2000 Pushbuttons Switches Pilot lights Components Signal Towers K 70 Signal Beacons K SB Pushbuttons, selector switches, toggle switches and pilot lights A complete range of state-of the art products ABB Control has a complete range of pushbuttons, selector switches and pilot lights of modern design that are easy to install. By combining a few basic components a large number of versions can be built up. They can be ordered in parts (operator + blocks with holder) or installed in an enclosure. ✔ Lenses and lamp caps have a large area, giving dependable operation. Pushbuttons and pilot lights are easy to tell apart. ✔ Pushbuttons, selector switches and toggle switches are available with three different bezels: black plastic, chrome plastic or metal. ✔ Terminals protected against inadvertant touching. (IP20) ✔ The contact blocks are colour coded for ease of wiring and inspection (NO is green, NC is red). The contacts have silver tips and are self-cleaning to ensure good conductivity even after long use. ✔ The lamp blocks can take either filament bulb, neon bulb, buzzer or LED. The bulbs can be changed from the front. ✔ Non-metallic or aluminium enclosures for rear mounting. Front mounting is available. ✔ A wide assortment of accessories including legend plates, bulbs, special blocks and enclosures are available. ✔ The design complies with all major international standards. ✔ The terminals on the contact blocks and lamp blocks are open. Wiring can be done separately before the blocks are snapped on the operator and holder or to the enclosure base. ✔ Pushbuttons, pilot lights and selector switches have an integrated spring-loaded tab. Used together with a notched hole it willl prevent the operator from rotating. Legend plates Of plastic or aluminium with slots that guide the legend plate and the operator into the correct position. Contact block Single pole with making or breaking contact. Operator Lenses and handles in several colours. Illuminated or non-illuminated. Sleeve and tightening nut The sleeve has bayonet fit. Lamp block Illuminated pushbuttons, selector switches and pilot lights have a lamp block in the centre position of the holder. Holder Available either for three blocks or five blocks in one single row. Additional blocks can be stacked. Bezels Pushbuttons, selector switches and toggle switches with bezel in black plastic, chrome plastic or metal are available. Easy to install The only tool needed is a screwdriver for connecting the wiring. 1. The operator is to be inserted from the front and secured at the back with a bayonet type sleeve and locking ring. 2 1SFC 261001-EN, Ed. 4 2. The holder is pushed onto the sleeve and secured with a latch. The contact block/lamp blocks are then snapped on. ABB Contents Pilot devices Non-illuminated Illuminated page page Pushbuttons, type K P 6 7 Double pushbuttons, type K PD 8 9-10 Key lockable pushbuttons, type K PK 11 Mushroom and emergency stop pushbuttons, type K PM, K PMT, KPMP, K PMK 12 – 14 Potentiometers, type K T 15 Selector switches, type K 2SS, K 3SS 16 – 17 Key-operated selector switches, type K 2SSK, K 3SSK 20 Toggle switches, type K TS 21 Pilot lights, type K L 22 Buzzers, type K B 22 12, 14 18–19 Signal Towers, type K 70 23 – 25 Signal Beacons, type K SB 26 Reset buttons 27 Enclosures and assembled stations ABB Non-metallic enclosures Metallic enclosures Assembled stations 28 32 34 Accessories Blocks Bulbs Legend plates 35 37 39 Miscellaneous Order forms Technical data Dimensions Colour selection Index of Order Codes ABB agencies and representatives Explanation of type designations 50 54 56 64 65 62 66 3 1SFC 261001-EN, Ed. 4 Selection Guide Pushbuttons Double pushbuttons Selector switches Mushrooms Key-lockable pushbuttons Pilot-lights 4 1SFC 261001-EN, Ed. 4 Contact block combinations Non-illuminated/momentary Non-illuminated/maintained Illuminated Contact block combinations Non-illuminated Illuminated Contact block combinations Non-illuminated Illuminated Contact block/ lamp block combinations Contact block combinations Lamp block combinations E-stop Toggle switches Contact block/lamp block combinations with safety holder Contact block combinations Compact pilot light ABB Selection Guide Panel holes Accessories Legend plates Text caps Sealing membrane Ø 30 Ø 22.5 Guard Hole adaptor panel 1.5 – 4 mm panel 1.5 – 6 mm For For Not together with flush extended legend plate button button holder Not together with legend plate holder Transformers Accessories Sealing membrane Accessories Legend plates Accessories Legend plates me rg e n c Stop Components y E Shackle Not together with legend plate. For 30 mm knob with twist release only. Potentiometers Reset buttons Buzzers Accessories Legend plates Accessories Legend plates ABB Text cap 5 1SFC 261001-EN, Ed. 4 Note: Both operator and contact block(s) must be ordered to get a complete pilot device Pushbuttons, non-illuminated Black plastic bezel Order Code Weight kg K P1-10R K P1-10G K P1-10Y K P1-10L K P1-10W K P1-10B K P1-10C 1SFA 616 100 R1001 1SFA 616 100 R1002 1SFA 616 100 R1003 1SFA 616 100 R1004 1SFA 616 100 R1005 1SFA 616 100 R1006 1SFA 616 100 R1008 0.016 0.016 0.016 0.016 0.016 0.016 0.016 K P2-10R K P2-10G K P2-10Y K P2-10L K P2-10W K P2-10B 1SFA 616 101 R1001 1SFA 616 101 R1002 1SFA 616 101 R1003 1SFA 616 101 R1004 1SFA 616 101 R1005 1SFA 616 101 R1006 0.016 0.016 0.016 0.016 0.016 0.016 K P3-10R K P3-10G K P3-10Y K P3-10L K P3-10W K P3-10B K P3-10C 1SFA 616 102 R1001 1SFA 616 102 R1002 1SFA 616 102 R1003 1SFA 616 102 R1004 1SFA 616 102 R1005 1SFA 616 102 R1006 1SFA 616 102 R1008 0.016 0.016 0.016 0.016 0.016 0.016 0.016 K P4-10R K P4-10G K P4-10Y K P4-10L K P4-10W K P4-10B 1SFA 616 103 R1001 1SFA 616 103 R1002 1SFA 616 103 R1003 1SFA 616 103 R1004 1SFA 616 103 R1005 1SFA 616 103 R1006 0.016 0.016 0.016 0.016 0.016 0.016 Type Order Code Weight kg Type Operator with flush button Momentary Button colour: Red Green Yellow Blue White Black Clear Maintained 1) Button colour: Red Green Yellow Blue White Black Operator with extended button Momentary Button colour: Red Green Yellow Blue White Black Clear Bezel in chrome plastic or metal Maintained 1) Replace 1 in the: Button colour: Type K PX-1 0X Cat. No. 1SFA 616 XXX R 1 XXX 2 for chrome plastic bezel 3 for metal bezel Red Green Yellow Blue White Black Blocks Contact blocks and holder 1 NO with holder 1 NC with holder 2 NO with holder 2 NC with holder 1 NO +1 NC with holder K CBH-10 K CBH-01 K CBH-20 K CBH-02 K CBH-11 1SFA 616 600 R1101 1SFA 616 600 R1110 1SFA 616 600 R1102 1SFA 616 600 R1120 1SFA 616 600 R1111 0.019 0.019 0.032 0.032 0.032 1 NO without holder 1 NC without holder K CB-10 K CB-01 SK 616 001-A SK 616 001-B 0.013 0.013 Holder for 3 blocks K CBH-00 SK 616 013-F 0.006 NO NC 1) 6 1SFC 261001-EN, Ed. 4 No contact block in the centre position. Accessories, see p. 35. Dimension drawings, see p. 56. ABB Note: Both operator and contact block(s) /lamp block must be ordered to get a complete pilot device Pushbuttons, illuminated Black plastic bezel Order Code Weight kg K P1-11R K P1-11G K P1-11Y K P1-11L K P1-11W K P1-11C 1SFA 616 100 R1101 1SFA 616 100 R1102 1SFA 616 100 R1103 1SFA 616 100 R1104 1SFA 616 100 R1105 1SFA 616 100 R1108 0.016 0.016 0.016 0.016 0.016 0.016 K P2-11R K P2-11G K P2-11Y K P2-11L K P2-11W K P2-11C 1SFA 616 101 R1101 1SFA 616 101 R1102 1SFA 616 101 R1103 1SFA 616 101 R1104 1SFA 616 101 R1105 1SFA 616 101 R1108 0.016 0.016 0.016 0.016 0.016 0.016 K P3-11R K P3-11G K P3-11Y K P3-11L K P3-11W K P3-11C 1SFA 616 102 R1101 1SFA 616 102 R1102 1SFA 616 102 R1103 1SFA 616 102 R1104 1SFA 616 102 R1105 1SFA 616 102 R1108 0.016 0.016 0.016 0.016 0.016 0.016 Button colour: Red Green Yellow Blue White Clear K P4-11R K P4-11G K P4-11Y K P4-11L K P4-11W K P4-11C 1SFA 616 103 R1101 1SFA 616 103 R1102 1SFA 616 103 R1103 1SFA 616 103 R1104 1SFA 616 103 R1105 1SFA 616 103 R1108 0.016 0.016 0.016 0.016 0.016 0.016 Blocks Type Order Code Weight kg Type Operator with flush button Momentary 1) Button colour: Red Green Yellow Blue White Clear Maintained 1) Button colour: Red Green Yellow Blue White Clear Operator with extended button Momentary 1) Button colour: Red Green Yellow Blue White Clear Maintained 1) Bezel in chrome plastic or metal Replace 1 in the: Type K PX-1 0X Cat. No. 1SFA 616 XXX R 1 XXX 2 for chrome plastic bezel 3 for metal bezel Contact blocks, lamp blocks and holder NO LB NC 1) ABB 1 NO + 1 LB with holder2) 1 NC + 1 LB with holder2) 2 NO + 1 LB with holder2) 2 NC + 1 LB with holder2) 1 NO +1 NC + 1 LB with holder2) K CBH-101 K CBH-011 K CBH-201 K CBH-021 K CBH-111 1SFA 616 600 R1201 1SFA 616 600 R1210 1SFA 616 600 R1202 1SFA 616 600 R1220 1SFA 616 600 R1211 0.034 0.034 0.047 0.047 0.047 1 NO without holder 1 NC without holder K CB-10 K CB-01 SK 616 001-A SK 616 001-B 0.013 0.013 Lampblock for 2 W, max. 230 V AC and DC bulb, neon bulb or LED K LB-1 SK 616 003-A 0.015 Holder for 3 blocks K CBH-00 SK 616 013-F 0.006 No contact block in the centre position. 2) Lamp block for max. 230 V AC/ DC. Bulb not included. For other lamp blocks see p 35. Accessories, see p. 35. Dimension drawings, see p. 56. 7 1SFC 261001-EN, Ed. 4 Note: Both operator and contact block(s) must be ordered to get a complete pilot device Double pushbuttons, non-illuminated Upper button Colour Text Lower button Colour Text Type Order Code Weight kg Operator with flush buttons 1) Green no text I ON START Red no text O OFF STOP K PD1-11B K PD2-11B K PD3-11B K PD4-11B 1SFA 616 130 R1106 1SFA 616 131 R1106 1SFA 616 132 R1106 1SFA 616 133 R1106 0.025 0.025 0.025 0.025 White no text I ON START Black no text O OFF STOP K PD5-11B K PD6-11B K PD7-11B K PD8-11B 1SFA 616 134 R1106 1SFA 616 135 R1106 1SFA 616 136 R1106 1SFA 616 137 R1106 0.025 0.025 0.025 0.025 Lens colour = black Operator with extended lower button 1) Green no text I ON START Red no text O OFF STOP K PD12-11B K PD13-11B K PD14-11B K PD15-11B 1SFA 616 141 R1106 1SFA 616 142 R1106 1SFA 616 143 R1106 1SFA 616 144 R1106 0.025 0.025 0.025 0.025 White no text I ON START Black no text O OFF STOP K PD16-11B K PD17-11B K PD18-11B K PD19-11B 1SFA 616 145 R1106 1SFA 616 146 R1106 1SFA 616 147 R1106 1SFA 616 148 R1106 0.025 0.025 0.025 0.025 Lens colour = black Blocks Type Order Code Weight kg Contact blocks and holder 2 NO with holder 2 NC with holder 1 NO +1 NC with holder K CBH-20 K CBH-02 K CBH-11 1SFA 616 600 R1102 1SFA 616 600 R1120 1SFA 616 600 R1111 0.032 0.032 0.032 1 NO without holder 1 NC without holder K CB-10 K CB-01 SK 616 001-A SK 616 001-B 0.013 0.013 Holder for 3 blocks K CBH-00 SK 616 013-F 0.006 NO NC 1) 8 1SFC 261001-EN, Ed. 4 No contact block in the centre position. Accessories, see p. 35. Dimension drawings, see p. 56. ABB Note: Both operator and contact block(s) /lamp block must be ordered to get a complete pilot device Double pushbuttons, illuminated Upper button Colour Text Lower button Colour Text Type Order Code Weight kg Operator with flush buttons 1) Red lens Lens colours - red - green - yellow - clear Green no text I ON START Red no text O OFF STOP K PD1-11R K PD2-11R K PD3-11R K PD4-11R 1SFA 616 130 R1101 1SFA 616 131 R1101 1SFA 616 132 R1101 1SFA 616 133 R1101 0.025 0.025 0.025 0.025 White no text I ON START Black no text O OFF STOP K PD5-11R K PD6-11R K PD7-11R K PD8-11R 1SFA 616 134 R1101 1SFA 616 135 R1101 1SFA 616 136 R1101 1SFA 616 137 R1101 0.025 0.025 0.025 0.025 Green lens Green no text I ON START Red no text O OFF STOP K PD1-11G K PD2-11G K PD3-11G K PD4-11G 1SFA 616 130 R1102 1SFA 616 131 R1102 1SFA 616 132 R1102 1SFA 616 133 R1102 0.025 0.025 0.025 0.025 White no text I ON START Black no text O OFF STOP K PD5-11G K PD6-11G K PD7-11G K PD8-11G 1SFA 616 134 R1102 1SFA 616 135 R1102 1SFA 616 136 R1102 1SFA 616 137 R1102 0.025 0.025 0.025 0.025 Yellow lens Green no text I ON START Red no text O OFF STOP K PD1-11Y K PD2-11Y K PD3-11Y K PD4-11Y 1SFA 616 130 R1103 1SFA 616 131 R1103 1SFA 616 132 R1103 1SFA 616 133 R1103 0.025 0.025 0.025 0.025 White no text I ON START Black no text O OFF STOP KPD5-11Y KPD6-11Y KPD7-11Y KPD8-11Y 1SFA 616 134 R1103 1SFA 616 135 R1103 1SFA 616 136 R1103 1SFA 616 137 R1103 0.025 0.025 0.025 0.025 Clear lens Green no text I ON START Red no text O OFF STOP K PD1-11C K PD2-11C K PD3-11C K PD4-11C 1SFA 616 130 R1108 1SFA 616 131 R1108 1SFA 616 132 R1108 1SFA 616 133 R1108 0.025 0.025 0.025 0.025 White no text I ON START Black no text O OFF STOP K PD5-11C K PD6-11C K PD7-11C K PD8-11C 1SFA 616 134 R1108 1SFA 616 135 R1108 1SFA 616 136 R1108 1SFA 616 137 R1108 0.025 0.025 0.025 0.025 Type Order Code Weight kg Blocks Contact blocks, lamp blocks and holder NO LB NC 1) ABB 2 NO + 1 LB with holder 2) 2 NC + 1 LB with holder 2) 1 NO +1 NC + 1 LB with holder 2) K CBH-201 K CBH-021 K CBH-111 1SFA 616 600 R1202 1SFA 616 600 R1220 1SFA 616 600 R1211 0.047 0.047 0.047 1 NO without holder 1 NC without holder K CB-10 K CB-01 SK 616 001-A SK 616 001-B 0.013 0.013 Lamp block for 2 W, max. 230 V AC and DC bulb, neon bulb or LED K LB-1 SK 616 003-A 0.015 Holder for 3 blocks K CBH-00 SK 616 013-F 0.006 No contact block in the centre position. 2) Lamp block for max. 230 V AC/ DC. Bulb not included. For other lamp blocks see p 35. Accessories, see p. 35. Dimension drawings, see p. 56. 9 1SFC 261001-EN, Ed. 4 Note: Both operator and contact block(s) /lamp block must be ordered to get a complete pilot device Double pushbuttons, illuminated Upper button Colour Text Lower button Colour Text Type Weight kg Order Code Operator with extended lower button buttons 1) Red lens Lens colours - red - green - yellow - clear Green no text I ON START Red no text O OFF STOP K PD12-11R K PD13-11R K PD14-11R K PD15-11R 1SFA 616 141 R1101 1SFA 616 142 R1101 1SFA 616 143 R1101 1SFA 616 144 R1101 0.025 0.025 0.025 0.025 White no text I ON START Black no text O OFF STOP K PD16-11R K PD17-11R K PD18-11R K PD19-11R 1SFA 616 145 R1101 1SFA 616 146 R1101 1SFA 616 147 R1101 1SFA 616 148 R1101 0.025 0.025 0.025 0.025 Green lens Green no text I ON START Red no text O OFF STOP K PD12-11G K PD13-11G K PD14-11G K PD15-11G 1SFA 616 141 R1102 1SFA 616 142 R1102 1SFA 616 143 R1102 1SFA 616 144 R1102 0.025 0.025 0.025 0.025 White no text I ON START Black no text O OFF STOP K PD16-11G K PD17-11G K PD18-11G K PD19-11G 1SFA 616 145 R1102 1SFA 616 146 R1102 1SFA 616 147 R1102 1SFA 616 148 R1102 0.025 0.025 0.025 0.025 Yellow lens Green no text I ON START Red no text O OFF STOP K PD12-11Y K PD13-11Y K PD14-11Y K PD15-11Y 1SFA 616 141 R1103 1SFA 616 142 R1103 1SFA 616 143 R1103 1SFA 616 144 R1103 0.025 0.025 0.025 0.025 White no text I ON START Black no text O OFF STOP K PD16-11Y K PD17-11Y K PD18-11Y K PD19-11Y 1SFA 616 145 R1103 1SFA 616 146 R1103 1SFA 616 147 R1103 1SFA 616 148 R1103 0.025 0.025 0.025 0.025 Clear lens Green no text I ON START Red no text O OFF STOP K PD12-11C K PD13-11C K PD14-11C K PD15-11C 1SFA 616 141 R1108 1SFA 616 142 R1108 1SFA 616 143 R1108 1SFA 616 144 R1108 0.025 0.025 0.025 0.025 White no text I ON START Black no text O OFF STOP K PD16-11C K PD17-11C K PD18-11C K PD19-11C 1SFA 616 145 R1108 1SFA 616 146 R1108 1SFA 616 147 R1108 1SFA 616 148 R1108 0.025 0.025 0.025 0.025 Type Order Code Weight kg Blocks Contact blocks, lamp block and holder NO LB NC 1) 10 1SFC 261001-EN, Ed. 4 2 NO + 1 LB with holder 2) 2 NC + 1 LB with holder 2) 1 NO +1 NC + 1 LB with holder 2) K CBH-201 K CBH-021 K CBH-111 1SFA 616 600 R1202 1SFA 616 600 R1220 1SFA 616 600 R1211 0.047 0.047 0.047 1 NO without holder 1 NC without holder K CB-10 K CB-02 SK 616 001-A SK 616 001-B 0.013 0.013 Lamp block for 2 W, max. 230 V AC and DC bulb, neon bulb or LED K LB-1 SK 616 003-A 0.015 Holder for 3 blocks K CBH-00 SK 616 013-F 0.006 No contact block in the centre position. 2) Lamp block for max. 230 V AC/ DC. Bulb not included. For other lamp blocks see p 35. Accessories, see p. 35. Dimension drawings, see p. 56. ABB Note: Both operator and contact block(s) must be ordered to get a complete pilot device Key-lockable pushbuttons Type Weight kg Order Code Maintained Locks, when depressed, can only be released with the key Key removable in both locked and unlocked position Ronis 455 (Key code 71) Ronis 421 (Key code 72) Ronis 3433-E (Key code 73) K PK1-101 K PK1-102 K PK1-103 1SFA 616 110 R1001 1SFA 616 110 R1002 1SFA 616 110 R1003 0.059 0.059 0.059 Momentary Can be operated without key when unlocked Key removable in both locked and unlocked position Key-lockable in non-depressed position Ronis 455 (Key code 71) K PK2-101 Ronis 421 (Key code 72) K PK2-102 Ronis 3433-E (Key code 73) K PK2-103 1SFA 616 111 R1001 1SFA 616 111 R1002 1SFA 616 111 R1003 0.059 0.059 0.059 Key-lockable in depressed position Ronis 455 (Key code 71) K PK3-101 Ronis 421 (Key code 72) K PK3-102 Ronis 3433-E (Key code 73) K PK3-103 1SFA 616 112 R1001 1SFA 616 112 R1002 1SFA 616 112 R1003 0.059 0.059 0.059 Key-lockable in both non-depressed and depressed position Ronis 455 (Key code 71) K PK4-101 1SFA 616 113 R1001 Ronis 421 (Key code 72) K PK4-102 1SFA 616 113 R1002 Ronis 3433-E (Key code 73) K PK4-103 1SFA 616 113 R1003 0.059 0.059 0.059 Can only be operated with the key Key removable in locked position The key-lockable pushbuttons are delivered with two keys. Other key codes On request Key-lockable in non-depressed position Ronis 455 (Key code 71) K PK5-101 Ronis 421 (Key code 72) K PK5-102 Ronis 3433-E (Key code 73) K PK5-103 1SFA 616 114 R1001 1SFA 616 114 R1002 1SFA 616 114 R1003 0.059 0.059 0.059 Key-lockable in depressed position Ronis 455 (Key code 71) K PK6-101 Ronis 421 (Key code 72) K PK6-102 Ronis 3433-E (Key code 73) K PK6-103 1SFA 616 115 R1001 1SFA 616 115 R1002 1SFA 616 115 R1003 0.059 0.059 0.059 Key-lockable in both non-depressed and depressed position Ronis 455 (Key code 71) K PK7-101 1SFA 616 116 R1001 Ronis 421 (Key code 72) K PK7-102 1SFA 616 116 R1002 Ronis 3433-E (Key code 73) K PK7-103 1SFA 616 116 R1003 0.059 0.059 0.059 Blocks Weight kg Type Order Code Contact blocks, lamp block and holder NO NC 1 NO with holder 1 NC with holder 2 NO with holder 2 NC with holder 1 NO +1 NC with holder K CBH-10 K CBH-01 K CBH-20 K CBH-02 K CBH-11 1SFA 616 600 R1101 1SFA 616 600 R1110 1SFA 616 600 R1102 1SFA 616 600 R1120 1SFA 616 600 R1111 0.019 0.019 0.032 0,032 0.032 1 NO without holder 1 NC without holder K CB-10 K CB-01 SK 616 001-A SK 616 001-B 0.013 0.013 Holder for 3 blocks K CBH-00 SK 616 013-F 0.006 Accessories, see p. 35. Dimension drawings, see p. 56. ABB 11 1SFC 261001-EN, Ed. 4 Note: Both operator and contact block(s) /lamp block must be ordered to get a complete pilot device Mushroom pushbuttons, momentary Non-illuminated and illuminated Operator material Button colour Type Order Code Weight kg Non-illuminated operators Ø 40 mm Plastic Red Yellow Black K PM1-10R K PM1-10Y K PM1-10B 1SFA 616 124 R1001 1SFA 616 124 R1003 1SFA 616 124 R1006 0.039 0.039 0.039 Red Yellow Black K PM2-10R K PM2-10Y K PM2-10B 1SFA 616 125 R1001 1SFA 616 125 R1003 1SFA 616 125 R1006 0.039 0.039 0.039 Red Yellow K PM1-11R K PM1-11Y 1SFA 616 124 R1101 1SFA 616 124 R1103 0.039 0.039 Red Yellow K PM2-11R K PM2-11Y 1SFA 616 125 R1101 1SFA 616 125 R1103 0.039 0.039 Type Order Code Weight kg Ø 60 mm Plastic Illuminated operators 1) Ø 40 mm Plastic Ø 60 mm Plastic Bezel in chrome plastic or metal Replace 1 in the: Type K PMX-1 XX Cat. No. 1SFA 616 XXX R 1 XXX 2 for chrome plastic bezel 3 for metal bezel Blocks Contact blocks, lamp block and holder NO 1 NO with holder 1 NC with holder 2 NO with holder 2 NC with holder 1 NO +1 NC with holder 1 NO + 1 LB with holder 2) 1 NC + 1 LB with holder 2) 2 NO + 1 LB with holder 2) 2 NC + 1 LB with holder 2) 1 NO +1 NC + 1 LB with holder 2) K CBH-10 K CBH-01 K CBH-20 K CBH-02 K CBH-11 K CBH-101 K CBH-011 K CBH-201 K CBH-021 K CBH-111 1SFA 616 600 R1101 1SFA 616 600 R1110 1SFA 616 600 R1102 1SFA 616 600 R1120 1SFA 616 600 R1111 1SFA 616 600 R1201 1SFA 616 600 R1210 1SFA 616 600 R1202 1SFA 616 600 R1220 1SFA 616 600 R1211 0.019 0.019 0.032 0.032 0.032 0.019 0.019 0.047 0.047 0.047 1 NO without holder 1 NC without holder K CB-10 K CB-01 SK 616 001-A SK 616 001-B 0.013 0.013 1 LB For max 230 V AC/DC bulb, neon bulb or LED K LB-1 SK 616 003-A 0.015 Holder for 3 blocks SK 616 013-F 0.006 K CBH-00 LB NC 1) 12 1SFC 261001-EN, Ed. 4 No contact block in the centre position. 2) Lamp block for max. 230 V AC/ DC. Bulb not included. For other lamp blocks see p 29. Accessories, see p. 35. Dimension drawings, see p. 56. ABB Note: Both operator and contact block(s) must be ordered to get a complete pilot device Mushroom pushbuttons Maintained. Operator material Button colour Type Order Code Weight kg Non-illuminated operators Operator Ø 30 mm Twist release Plastic Red K PMT1-10R 1SFA 616 500 R1001 0.039 Black K PMT1-10B 1SFA 616 500 R1006 0.039 Red K PMP1-10R 1SFA 616 501 R1001 0.039 Black K PMP1-10B 1SFA 616 501 R1006 0.039 Pull release Plastic Operator Ø 40 mm Key release (key code 71, Ronis 455) Plastic Red K PMK2-10R 1SFA 616 504 R1001 0.079 Black K PMK2-10B 1SFA 616 504 R1006 0.079 Type Order Code Weight kg The mushroom pushbutton with key release is delivered with two keys. Blocks Contact blocks with holder NO NC 1 NO with holder 1 NC with holder 2 NO with holder 2 NC with holder 1 NO +1 NC with holder K CBH-10 K CBH-01 K CBH-20 K CBH-02 K CBH-11 1SFA 616 600 R1101 1SFA 616 600 R1110 1SFA 616 600 R1102 1SFA 616 600 R1120 1SFA 616 600 R1111 0.019 0.019 0.032 0.032 0.032 1 NO without holder 1 NC without holder K CB-10 K CB-01 SK 616 001-A SK 616 001-B 0.013 0.013 Holder for 3 blocks K CBH-00 SK 616 013-F 0.006 Accessories, see p. 35. Dimension drawings, see p. 56. ABB 13 1SFC 261001-EN, Ed. 4 Note: Both operator and contact block(s) /lamp block must be ordered to get a complete pilot device Emergency stop pushbuttons Non-illuminated and illuminated Operator function Operator material, colour Type Order Code Weight kg Non-illuminated operators Ø 40 mm Twist release Pull release Plastic, red Plastic, red K PMT3-10R K PMP3-10R 1SFA 616 510 R1001 1SFA 616 511 R1001 0.041 0.041 Plastic, red Plastic, red K PMT4-10R PMP4-10R 1SFA 616 513 R1001 1SFA 616 514 R1001 0.048 0.048 Plastic, red Plastic, red K PMT3-11R K PMP3-11R 1SFA 616 510 R1101 1SFA 616 511 R1101 0.041 0.041 Plastic, red Plastic, red K PMT4-11R K PMP4-11R 1SFA 616 513 R1101 1SFA 616 514 R1101 0.048 0.048 Ø 60 mm Twist release Pull release Illuminated operators Ø 40 mm Twist release Pull release Ø 60 mm Twist release Pull release Use adapter plate 1SFA 616 920 R 8014 (see page 29) when using non-metallic enclosure. ● The safety holder below can only be used for the the above mentioned type of Emergency stop pushbuttons. ● Blocks Type Weight kg Order Code Contact blocks and lamp block with safety holder for emergency stop pushbuttons 1) 1 NO with safety holder 1 NC with safety holder 2 NO with safety holder 2 NC with safety holder 1 NO +1 NC with safety holder 1 NO +1 LB with safety holder 2) 1 NC +1 LB with safety holder 2) 2 NO +1 LB with safety holder 2) 2 NC +1 LB with safety hoolder 2) 1 NO +1 NC +1 LB with safety holder2) 1 NO without safety holder K CB-10 1 NC without safety holder K CB-01 1 LB For max 230 V AC/DC bulb, neon bulb or LED without safety holder K LB-1 Safety holder E-stop K CBHS-00 NO LB NC 1) 14 1SFC 261001-EN, Ed. 4 K CBHS-10 K CBHS-01 K CBHS-20 K CBHS-02 K CBHS-11 K CBHS-101 K CBHS-011 K CBHS-201 K CBHS-021 K CBHS-111 No contact block in the centre position for the illuminated operators. 2) 1SFA 616 605 R1101 1SFA 616 605 R1110 1SFA 616 605 R1102 1SFA 616 605 R1120 1SFA 616 605 R1111 1SFA 616 605 R1201 1SFA 616 605 R1210 1SFA 616 605 R1202 1SFA 616 605 R1220 1SFA 616 605 R1211 0.021 0.021 0.032 0.032 0.032 0.033 0.033 0.044 0.044 0.044 SK 616 001-A SK 616 001-B 0.013 0.013 SK 616 003-A 1SFA 616 605 R1100 0.015 0.010 Lamp block for max. 230 V AC/ DC. Bulb not included. For other lamp blocks see p 35. Accessories, see p. 35. Dimension drawings, see p. 56. ABB Potentiometer Bezel Type Order Code Weight kg Complete potentiometer - with resistor 5 kΩ Black knob with integrated position indication and marking in white. Black plastic Chrome plastic Metal K T-105B K T-205B K T-305B 1SFA 616 410 R1056 1SFA 616 410 R2056 1SFA 616 410 R3056 0.034 0.034 0.042 Complete potentiometer - with resistor 10 kΩ Black knob with integrated position indication and marking in white. Black plastic Chrome plastic Metal Resistor data Element type Power rating Mechanical angle Terminals Insulation voltage Operating temperature Cermet 2W 280° Solder lugs 900 V -1°C to + 70°C K T-110B K T-210B K T-310B 1SFA 616 410 R1106 1SFA 616 410 R2106 1SFA 616 410 R3106 0.034 0.034 0.042 Operating knob - without resistor Black knob with integrated position indication and marking in white. For shaft diameter 6 - 6.35 mm. Min. shaft length 20 mm. Black plastic Chrome plastic Metal K T-1B K T-2B K T-3B 1SFA 616 410 R1006 1SFA 616 410 R2006 1SFA 616 410 R3006 0.023 0.023 0.031 Suitable legend plate - see page 45. ABB 15 1SFC 261001-EN, Ed. 4 Note: Both operator and contact block(s) must be ordered to get a complete pilot device Two-position selector switches, non-illuminated Black plastic bezel Weight Symbol Handle colour Type Order Code kg Operator with short handle 1) Maintained Red Black Grey K 2SS1-10R K 2SS1-10B K 2SS1-10U 1SFA 616 200 R1001 1SFA 616 200 R1006 1SFA 616 200 R1007 0.024 0.024 0.024 Red Black Grey K 2SS2-10R K 2SS2-10B K 2SS2-10U 1SFA 616 201 R1001 1SFA 616 201 R1006 1SFA 616 201 R1007 0.024 0.024 0.024 1SFA 616 202 R1001 1SFA 616 202 R1006 1SFA 616 202 R1007 0.024 0.024 0.024 Maintained Momentary, spring return from C to B Red Black Grey K 2SS3-10R K 2SS3-10B K 2SS3-10U Operator with long handle 1) Maintained Red Black Grey K 2SS4-10R K 2SS4-10B K 2SS4-10U 1SFA 616 203 R1001 1SFA 616 203 R1006 1SFA 616 203 R1007 0.025 0.025 0.025 Red Black Grey K 2SS5-10R K 2SS5-10B K 2SS5-10U 1SFA 616 204 R1001 1SFA 616 204 R1006 1SFA 616 204 R1007 0.025 0.025 0.025 K 2SS6-10R K 2SS6-10B K 2SS6-10U 1SFA 616 205 R1001 1SFA 616 205 R1006 1SFA 616 205 R1007 0.025 0.025 0.025 Type Order Code Weight kg Maintained Bezel in chrome plastic or metal Replace 1 in the: Momentary, spring return from C to B Type K 2SSX-1 0X Cat. No. 1SFA 616 XXX R 1 XXX Red Black Grey 2 for chrome plastic bezel 3 for metal bezel Blocks Contact blocks and holder NO NC Contact functions Block positions as seen from operator front. Handle position Left block Right block A (B) O O O x x 1) 1 NO with holder K CBH-10 1SFA 616 600 R1101 0.019 1 NC with holder K CBH-01 1SFA 616 600 R1110 0.019 2 NO with holder K CBH-20 1SFA 616 600 R1102 0.032 2 NC with holder K CBH-02 1SFA 616 600 R1120 0.032 1 NO +1 NC with holder K CBH-11 1SFA 616 600 R1111 0.032 1 NO without holder K CB-10 SK 616 001-A 0.013 1 NC without holder K CB-01 SK 616 001-B 0.013 Holder for 3 blocks K CBH-00 SK 616 013-F 0.006 No contact block in the centre position. Accessories, see p. 35. Dimension drawings, see p. 56. O = not influenced (normal state) x = influenced (state changed) 16 1SFC 261001-EN, Ed. 4 ABB Note: Both operator and contact block(s) must be ordered to get a complete pilot device Three-position selector switches, non-illuminated Black plastic bezel Symbol Handle colour Type Order Code Weight kg 1SFA 616 210 R1001 1SFA 616 210 R1006 1SFA 616 210 R1007 0.024 0.024 0.024 Operator with short handle 1) Maintained Red Black Grey K 3SS1-10R K 3SS1-10B K 3SS1-10U Momentary, spring return from A to B and C to B Red Black Grey K 3SS2-10R K 3SS2-10B K 3SS2-10U 1SFA 616 211 R1001 1SFA 616 211 R1006 1SFA 616 211 R1007 0.024 0.024 0.024 1SFA 616 212 R1001 1SFA 616 212 R1006 1SFA 616 212 R1007 0.024 0.024 0.024 1SFA 616 216 R1001 1SFA 616 216 R1006 1SFA 616 216 R1007 0.024 0.024 0.024 1SFA 616 213 R1001 1SFA 616 213 R1006 1SFA 616 213 R1007 0.025 0.025 0.025 Momentary, spring return from C to B Red Black Grey K 3SS3-10R K 3SS3-10B K 3SS3-10U Momentary, spring return from A to B Red Black Grey K 3SS7-10R K 3SS7-10B K 3SS7-10U Operator with long handle 1) Maintained Red Black Grey K 3SS4-10R K 3SS4-10B K 3SS4-10U Momentary, spring return from A to B and C to B Red Black Grey K 3SS5-10R K 3SS5-10B K 3SS5-10U 1SFA 616 214 R1001 1SFA 616 214 R1006 1SFA 616 214 R1007 0.025 0.025 0.025 1SFA 616 215 R1001 1SFA 616 215 R1006 1SFA 616 215 R1007 0.025 0.025 0.025 1SFA 616 217 R1001 1SFA 616 217 R1006 1SFA 616 217 R1007 0.025 0.025 0.025 Momentary, spring return from C to B Bezel in chrome plastic or metal Red Black Grey Replace 1 in the: K 3SS6-10R K 3SS6-10B K 3SS6-10U Type K 3SSX-1 0X Cat. No. 1SFA 616 XXX R 1 XXX Momentary, spring return from A to B 2 for chrome plastic bezel Red Black Grey 3 for metal bezel K 3SS8-10R K 3SS8-10B K 3SS8-10U Contact blocks and holder – see page 16 Contact functions Block positions as seen from operator front. Handle position Left block Right block A x O B O O C O x 1) No contact block in the centre position. Accessories, see p. 35. Dimension drawings, see p. 56. O = not influenced (normal state) x = influenced (state changed) ABB 17 1SFC 261001-EN, Ed. 4 Note: Both operator and contact block(s) /lamp block must be ordered to get a complete pilot device Two-position selector switches, illuminated Black plastic bezel Weight Symbol Handle colour Type Order Code kg Operator with short handle 1) Maintained Red Gren Yellow Blue Clear K 2SS1-11R K 2SS1-11G K 2SS1-11Y K 2SS1-11L K 2SS1-11C 1SFA 616 200 R1101 1SFA 616 200 R1102 1SFA 616 200 R1103 1SFA 616 200 R1104 1SFA 616 200 R1108 0.024 0.024 0.024 0.024 0.024 Red Gren Yellow Blue Clear K 2SS2-11R K 2SS2-11G K 2SS2-11Y K 2SS2-11L K 2SS2-11C 1SFA 616 201 R1101 1SFA 616 201 R1102 1SFA 616 201 R1103 1SFA 616 201 R1104 1SFA 616 201 R1108 0.024 0.024 0.024 0.024 0.024 1SFA 616 202 R1101 1SFA 616 202 R1102 1SFA 616 202 R1103 1SFA 616 202 R1104 1SFA 616 202 R1108 0.024 0.024 0.024 0.024 0.024 Maintained Momentary, spring return from C to B Red Gren Yellow Blue Clear K 2SS3-11R K 2SS3-11G K 2SS3-11Y K 2SS3-11L K 2SS3-11C Operator with long handle 1) Maintained Red Gren Yellow Blue Clear K 2SS4-11R K 2SS4-11G K 2SS4-11Y K 2SS4-11L K 2SS4-11C 1SFA 616 203 R1101 1SFA 616 203 R1102 1SFA 616 203 R1103 1SFA 616 203 R1104 1SFA 616 203 R1108 0.025 0.025 0.025 0.025 0.025 Red Gren Yellow Blue Clear K 2SS5-11R K 2SS5-11G K 2SS5-11Y K 2SS5-11L K 2SS5-11C 1SFA 616 204 R1101 1SFA 616 204 R1102 1SFA 616 204 R1103 1SFA 616 204 R1104 1SFA 616 204 R1108 0.025 0.025 0.025 0.025 0.025 K 2SS6-11R K 2SS6-11G K 2SS6-11Y K 2SS6-11L K 2SS6-11C 1SFA 616 205 R1101 1SFA 616 205 R1102 1SFA 616 205 R1103 1SFA 616 205 R1104 1SFA 616 205 R1108 0.025 0.025 0.025 0.025 0.025 Type Order Code Maintained Bezel in chrome plastic or metal Replace 1 in the: Type K 2SSX-1 1X Cat. No. 1SFA 616 XXX R 1 1XX Momentary, spring return from C to B 2 for chrome plastic bezel Red Gren Yellow Blue Clear 3 for metal bezel Blocks Weight, kg Contact blocks, lamp block and holder 1 NO + 1 LB with holder 2) K CBH-101 1SFA 616 600 R1201 0.034 1 NC + 1 LB with holder 2) K CBH-011 1SFA 616 600 R1210 0.034 2 NO + 1 LB with holder 2) K CBH-201 1SFA 616 600 R1202 0.047 2 NC + 1LB with holder K CBH-021 1SFA 616 600 R1220 0.047 K CBH-111 K CB-10 K CB-01 1SFA 616 600 R1211 SK 616 001-A SK 616 001-B 0.047 0.013 0.013 K LB-1 K CBH-00 SK 616 003-A SK 616 013-F 0.013 0.006 2) 1 NO +1 NC + 1 LB with holder 2) 1 NO without holder 1 NC without holder Lamp block for 2 W, max230 V AC and DC bulb, neon bulb or LED Holder for 3 blocks NO LB NC Contact functions Block positions as seen from operator front. Handle position Left block Right block A (B) O O O x x 1) No contact block in the centre position. 2) Lamp block for max. 230 V AC/ DC. Bulb not included. For other lamp blocks see p. 35 Accessories, see p. 35. Dimension drawings, see p. 56. O = not influenced (normal state) x = influenced (state changed) 18 1SFC 261001-EN, Ed. 4 ABB Note: Both operator and contact block(s) /lamp block must be ordered to get a complete pilot device Three-position selector switches, illuminated Black plastic bezel Symbol Handle colour Type Weight kg Order Code Operator with short handle 1) Maintained Red Gren Yellow Blue Clear K 3SS1-11R K 3SS1-11G K 3SS1-11Y K 3SS1-11L K 3SS1-11C 1SFA 616 210 R1101 1SFA 616 210 R1102 1SFA 616 210 R1103 1SFA 616 210 R1104 1SFA 616 210 R1108 0.024 0.024 0.024 0.024 0.024 Momentary, spring return from A to B and C to B Red Gren Yellow Blue Clear K 3SS2-11R K 3SS2-11G K 3SS2-11Y K 3SS2-11L K 3SS2-11C 1SFA 616 211 R1101 1SFA 616 211 R1102 1SFA 616 211 R1103 1SFA 616 211 R1104 1SFA 616 211 R1108 0.024 0.024 0.024 0.024 0.024 1SFA 616 212 R1101 1SFA 616 212 R1102 1SFA 616 212 R1103 1SFA 616 212 R1104 1SFA 616 212 R1108 0.024 0.024 0.024 0.024 0.024 1SFA 616 216 R1101 1SFA 616 216 R1102 1SFA 616 216 R1103 1SFA 616 216 R1104 1SFA 616 216 R1108 0.024 0.024 0.024 0.024 0.024 1SFA 616 213 R1101 1SFA 616 213 R1102 1SFA 616 213 R1103 1SFA 616 213 R1104 1SFA 616 213 R1108 0.025 0.025 0.025 0.025 0.025 Momentary, spring return from C to B Red Gren Yellow Blue Clear K 3SS3-11R K 3SS3-11G K 3SS3-11Y K 3SS3-11L K 3SS3-11C Momentary, spring return from A to B Red Gren Yellow Blue Clear K 3SS7-11R K 3SS7-11G K 3SS7-11Y K 3SS7-11L K 3SS7-11C Operator with long handle 1) Maintained Red Gren Yellow Blue Clear K 3SS4-11R K 3SS4-11G K 3SS4-11Y K 3SS4-11L K 3SS4-11C Momentary, spring return from A to B and C to B Red Gren Yellow Blue Clear K 3SS5-11R K 3SS5-11G K 3SS5-11Y K 3SS5-11L K 3SS5-11C 1SFA 616 214 R1101 1SFA 616 214 R1102 1SFA 616 214 R1103 1SFA 616 214 R1104 1SFA 616 214 R1108 0.025 0.025 0.025 0.025 0.025 1SFA 616 215 R1101 1SFA 616 215 R1102 1SFA 616 215 R1103 1SFA 616 215 R1104 1SFA 616 215 R1108 0.025 0.025 0.025 0.025 0.025 1SFA 616 217 R1101 1SFA 616 217 R1102 1SFA 616 217 R1103 1SFA 616 217 R1104 1SFA 616 217 R1108 0.025 0.025 0.025 0.025 0.025 Momentary, spring return from C to B Bezel in chrome plastic or metal Red Gren Yellow Blue Clear Replace 1 in the: Type K 3SSX-1 1X Cat. No. 1SFA 616 XXX R 1 1XX K 3SS6-11R K 3SS6-11G K 3SS6-11Y K 3SS6-11L K 3SS6-11C 2 for chrome plastic bezel Momentary, spring return from A to B 3 for metal bezel Red Gren Yellow Blue Clear K 3SS8-11R K 3SS8-11G K 3SS8-11Y K 3SS8-11L K 3SS8-11C Contact blocks, lamp block and holder – see page 18 Contact functions Block positions as seen from operator front. Handle position Left block Right block A x O B O O C O x 1) No contact block in the centre position. 2) Lamp block for max. 230 V AC/ DC. Bulb not included. For other lamp blocks see p. 35 Accessories, see p. 35. Dimension drawings, see p. 56. O = not influenced (normal state) x = influenced (state changed) ABB 19 1SFC 261001-EN, Ed. 4 Note: Both operator and contact block(s) must be ordered to get a complete pilot device Key-operated selector switches Symbol The key can be removed Type Order Code Weight kg Operator – two positions 3) Maintained In both positions K 2SSK1-10■ 1) 1SFA 616 280 R100 ■ 1) 0.069 In position B only K 2SSK2-10■ 1) 1SFA 616 281 R100 ■ 1) 0.069 1SFA 616 282 R100 ■ 1) 0.069 Maintained The key-operated selector switches are delivered with two keys. Momentary, spring return from C to B In position B only K 2SSK3-10■ 1) Operator – three positions 3) Maintained In all positions K 3SSK1-10■ 1) 1SFA 616 283 R100 ■ 1) 0.069 In position B only K 3SSK2-10■ 1) 1SFA 616 284 R100 ■ 1) 0.069 Maintained 1 ) Key code codes Momentary, spring return from A to B and C to B Key code Code 71 (standard) 72 73 Other ■=1 ■=2 ■=3 In position B only K 3SSK3-10■ 1) 1SFA 616 285 R100 ■ 1) 0.069 1SFA 616 286 R100 ■ 2) 0.069 1SFA 616 287 R100 ■ 1) 0.069 Momentary, spring return from C to B On request In position A only K 3SSK4-10■ 1) 2 ) Key code codes Key code Code 71 (standard) 72 ■=1 ■=2 Momentary, spring return from C to B In all positions *) K 3SSK5-10■ 1) To improve antirotation use guide washer 2154 373-2. See page 38. Blocks Type Order Code Weight kg Contact blocks and holder 2 NO with holder K CBH-20 1SFA 616 600 R1102 0.032 2 NC with holder K CBH-02 1SFA 616 600 R1120 0.032 1 NO +1 NC with holder K CBH-11 1SFA 616 600 R1111 0.032 1 NO without holder K CB-10 SK 616 001-A 0.013 1 NC without holder K CB-01 SK 616 001-B 0.013 Holder for 3 blocks K CBH-00 SK 616 013-F 0.006 NO NC Contact functions Two positions: see page 18 3) No contact block in the centre position. Accessories, see p. 35. Dimension drawings, see p. 56. Three positions: see page 19 20 1SFC 261001-EN, Ed. 4 ABB Note: Both operator and contact block(s) must be ordered to get a complete pilot device Toggle switches Symbol Bezel Type Order Code Weight kg K TS1-10B K TS1-20B K TS1-30B 1SFA 616 300 R1006 1SFA 616 300 R2006 1SFA 616 300 R3006 0.021 0.021 0.021 Operator – two positions Maintained 1) Black plastic Chrome plastic Metal Operator – three positions Momentary, spring return from A to B and C to B 1) Black plastic Chrome plastic Metal K TS2-10B K TS2-20B K TS2-30B 1SFA 616 301 R1006 1SFA 616 301 R2006 1SFA 616 301 R3006 0.021 0.021 0.021 K TS3-10B K TS3-20B K TS3-30B 1SFA 616 302 R1006 1SFA 616 302 R2006 1SFA 616 302 R3006 0.021 0.021 0.021 Type Cat.No. Weight kg Maintained 2) Black plastic Chrome plastic Metal Blocks Contact blocks and holder NO NC 1 NO with holder K CBH-10 1SFA 616 600 R1101 0.019 1 NC with holder K CBH-01 1SFA 616 600 R1110 0.019 2 NO with holder K CBH-20 1SFA 616 600 R1102 0.032 2 NC with holder K CBH-02 1SFA 616 600 R1120 0.032 1 NO +1 NC with holder K CBH-11 1SFA 616 600 R1111 0.032 1 NO without holder K CB-10 SK 616 001-A 0.013 1 NC without holder K CB-01 SK 616 001-B 0.013 Holder for 3 blocks K CBH-00 SK 616 013-F 0.006 Contact functions Block positions as seen from operator front. Right block Three-position momentary switch Handle Left Right position block block Three-position maintained switch Handle Left Middle Right position block block block O O A x O A O x x x x B O O B O O O C O x C x x O Two-position switch Handle Left position block A C O = not influenced (normal state) x = influenced (state changed) ABB O = not influenced (normal state) x = influenced (state changed) 1) No contact block in centre position. 2) Contact block in centre position is influenced in both position A and C. Accessories, see p. 35. Dimension drawings, see p. 56. O = not influenced (normal state) x = influenced (state changed) 21 1SFC 261001-EN, Ed. 4 Note: Both pilot light head and lamp block must be ordered to get a complete pilot light Pilot lights and buzzers Lens colour Weight, kg Type Order Code Red Green Yellow Blue White Clear K L1-100R K L1-100G K L1-100Y K L1-100L K L1-100W K L1-100C 1SFA 616 400 R1001 1SFA 616 400 R1002 1SFA 616 400 R1003 1SFA 616 400 R1004 1SFA 616 400 R1005 1SFA 616 400 R1008 Supply voltage Type Order Code Pilot light heads 1) 0.018 0.018 0.018 0.018 0.018 0.018 Weight, kg Lamp blocks with holder max. 230 V AC /DC 1) K CBH-001 1SFA 616 600 R1200 0.021 115 V AC 1) K CBH-002 1SFA 616 600 R1300 0.023 230 V AC 1) K CBH-003 1SFA 616 600 R1400 0.026 Type Order Code Lens colour Weight, kg Compact Pilot lights 1) Direct supply. max 240 V, 3 W. Use filament bulb for best light. With LED or neon bulb add light diffusing lens. Red Green Yellow Blue White Clear K L2-100R K L2-100G K L2-100Y K L2-100L K L2-100W K L2-100C Type 1SFA 616 402 R1001 1SFA 616 402 R1002 1SFA 616 402 R1003 1SFA 616 402 R1004 1SFA 616 402 R1005 1SFA 616 402 R1008 0.017 0.017 0.017 0.017 0.017 0.017 Weight, kg Order Code Light diffusing lens – Accessory for pilot light The lens is used instead of text cap Supply voltage Tone type 1SFA 616 920 R8005 Type 0.001 Weight, kg Order Code Buzzers Black. Frequency: Approx. 2400 Hz. Loudness: Min 80 dB(A)/10 cm, Rated current:≤8 mA. Service life >5000 h 24 V AC/DC Continuous K B1-4010 1SFA 616 401 R4010 115 V AC/DC Continuous K B1-4030 1SFA 616 401 R4030 230 V AC Continuous K B1-4040 1SFA 616 401 R4040 24 V AC/DC Pulsating K B1-4110 1SFA 616 401 R4110 115 V AC/DC Pulsating K B1-4130 1SFA 616 401 R4130 230 V AC Pulsating K B1-4140 1SFA 616 401 R4140 1) 22 1SFC 261001-EN, Ed. 4 Bulb not included. 0.020 0.020 0.020 0.020 0.020 0.020 Accessories, see p. 29 Dimension drawings, see p. 56-57 ABB Signal Towers K 70 and Signal Beacons K SB Signal Towers K 70 - Fast mounting of signal elements using bayonet fixing - Easy changing of bulbs for each module without tools Simple fitting with quick fix system Each K 70 module is equipped with a bayonet fixing with integral contact system. The modules are fastened together by aligning the corresponding white marks then with a gentle twist they are locked into place (see the figures). - Flexibility of signal element combination - Up to 5 elements possible/up to 10 elements with bracket for 2-sided mounting - Flashing light elements can be mounted in each module - Up to 5 flashing light elements possible - High protection rating optical and audible signal elements with IP 54. - LED elements for long life Connection plan Connection plan with AS Interface module Uextern (-) Uextern (+) 4 3 2 1 ASI (+) 5 0 ASI (-) Signal Beacons K SB - Vandal-proof design withstands every mechanical and natural challenge both indoors and outdoors. - High protection rating IP 65 - Cap consists of high impact polycarbonate (up to 20 J). - Bulb change via inside of control box. ABB 23 1SFC 261001-EN, Ed. 4 Signal Towers K 70 Colour Type Order Code Weight, kg Optical modules Light element Permanent light, 12-240 V AC/DC. For bulb BA15d. Bulb not included. Red Green Yellow Blue Clear K L70-401R K L70-401G K L70-401Y K L70-401L K L70-401C 1SFA 616 070 R4011 1SFA 616 070 R4012 1SFA 616 070 R4013 1SFA 616 070 R4014 1SFA 616 070 R4018 0.09 0.09 0.09 0.09 0.09 Blinking light, 24 V AC/DC. For bulb BA15d. Bulb not included. Red Green Yellow Blue Clear K L70-302R K L70-302G K L70-302Y K L70-302L K L70-302C 1SFA 616 070 R3021 1SFA 616 070 R3022 1SFA 616 070 R3023 1SFA 616 070 R3024 1SFA 616 070 R3028 0.10 0.10 0.10 0.10 0.10 Flashing light, 24 V DC. Xenon tube included. Not changeable. Red Green Yellow Blue Clear K L70-203R K L70-203G K L70-203Y K L70-203L K L70-203C 1SFA 616 070 R2031 1SFA 616 070 R2032 1SFA 616 070 R2033 1SFA 616 070 R2034 1SFA 616 070 R2038 0.12 0.12 0.12 0.12 0.12 Blinking light, 115 V AC/DC. For bulb BA15d. Bulb not included. Red Green Yellow Blue Clear K L70-312R K L70-312G K L70-312Y K L70-312L K L70-312C 1SFA 616 070 R3121 1SFA 616 070 R3122 1SFA 616 070 R3123 1SFA 616 070 R3124 1SFA 616 070 R3128 0.10 0.10 0.10 0.10 0.10 Flashing light, 115 V AC. Xenon tube included. Not changeable. Red Green Yellow Blue Clear K L70-113R K L70-113G K L70-113Y K L70-113L K L70-113C 1SFA 616 070 R1131 1SFA 616 070 R1132 1SFA 616 070 R1133 1SFA 616 070 R1134 1SFA 616 070 R1138 0.11 0.11 0.11 0.11 0.11 Blinking light, 230 V AC/DC. For bulb BA15d. Bulb not included. Red Green Yellow Blue Clear K L70-322R K L70-322G K L70-322Y K L70-322L K L70-322C 1SFA 616 070 R3221 1SFA 616 070 R3222 1SFA 616 070 R3223 1SFA 616 070 R3224 1SFA 616 070 R3228 0.10 0.10 0.10 0.10 0.10 Flashing light, 230 V AC. Xenon tube included. Not changeable. Red Green Yellow Blue Clear K L70-123R K L70-123G K L70-123Y K L70-123L K L70-123C 1SFA 616 070 R1231 1SFA 616 070 R1232 1SFA 616 070 R1233 1SFA 616 070 R1234 1SFA 616 070 R1238 0.11 0.11 0.11 0.11 0.11 LED Permanent light, 24 V AC/DC. LED included. Not changeable. Red Green Yellow K L70-305R K L70-305G K L70-305Y 1SFA 616 070 R3051 1SFA 616 070 R3052 1SFA 616 070 R3053 0.10 0.10 0.10 LED Blinking light, 24 V AC/DC. LED included. Not changeable. Red Green Yellow K L70-306R K L70-306G K L70-306Y 1SFA 616 070 R3061 1SFA 616 070 R3062 1SFA 616 070 R3063 0.10 0.10 0.10 LED Rotating light, 24 V AC/DC. LED included. Not changeable. Red Green Yellow K L70-307R K L70-307G K L70-307Y 1SFA 616 070 R3071 1SFA 616 070 R3072 1SFA 616 070 R3073 0.10 0.10 0.10 Bulbs for Signal Tower K 70 Max 7 W For permanent or blinking light. Bulb BA15d, 42 mm, : 24 V, 5 W 115 V, 5 W 230 V, 5 W 1SFA 616 923 R1028 1SFA 616 923 R1118 1SFA 616 923 R1148 0.009 0.009 0.009 Dimension drawings, see p. 58. 24 1SFC 261001-EN, Ed. 4 ABB Signal Towers K 70 Accessories Description Type Order Code Weight, kg Audible modules Buzzer element 85 dB, continuous or pulsating tone, adjustable 230 V AC K B70-1201 1SFA 616 071 R1201 24 V AC/DC K B70-3001 1SFA 616 071 R3001 115 V AC/DC K B70-3101 1SFA 616 071 R3101 0.12 0.11 0.11 Siren element Multi function, 8 diff. tones adjustable, volume adjustable 100 dB, 115 V AC K S70-1104 1SFA 616 073 R1104 0.13 Multi function, 8 diff. tones adjustable, volume adjustable 100 dB, 230 V AC K S70-1204 1SFA 616 073 R1204 0.12 Multi function, 7 diff. tones adjustable, volume adjustable, remote control 100 dB, 24 V DC K S70-2004 1SFA 616 073 R2004 0.12 Multi function, 8 diff. tones adjustable, volume adjustable 100 dB, 24 V AC/DC K S70-3004 1SFA 616 073 R3004 0.12 Continuous tone alternating 108 dB, 24 V DC K S70-2002 1SFA 616 073 R2002 0.15 AS-Interface Module { K ASI-4101 1SFA 616 079 R4101 0.11 for external voltage 18,5-31,6 V AC/DC K ASI-4102 1SFA 616 079 R4102 0.14 Terminal elements (K T70) max 5 elements 18,5-31,6 V AC/DC K B70/K S70 For tube mounting, including cap K T70-1001 1SFA 616 075 R1001 0.15 For bracket or base, including cap K T70-1002 1SFA 616 075 R1002 0.15 Cable exit at side K A70-1001 1SFA 616 077 R1001 0.07 Magnetic base K A70-1002 1SFA 616 077 R1002 0.31 D=25 mm L=110 mm K A70-1011 1SFA 616 077 R1011 0.06 K ASI K L70 K T70-1002 K T70-1001 Special parts Contact box K A70-1021 K A70-1031 K A70-1001 K A70-1032 K A70-1022 K A70-1001 Base with tube Base for tube D=25 mm, Plastic K A70-1012 1SFA 616 077 R1012 0.03 D=25 mm, Metal K A70-1013 1SFA 616 077 R1013 0.32 K A70-1011 K A70-1013 Tube, anodized aluminium KA 70-1012 D=25 mm L=250 mm K A70-1021 1SFA 616 077 R1021 0.08 D=25 mm L=400 mm K A70-1022 1SFA 616 077 R1022 0.12 K A70-1001 Bracket K A70-1002 1-sided mounting K A70-1031 1SFA 616 077 R1031 0.08 2-sided mounting K A70-1032 1SFA 616 077 R1032 0.07 Dimension drawings, see p. 58. ABB 25 1SFC 261001-EN, Ed. 4 Signal Beacons K SB Colour Type Order Code Weight, kg Signal Beacons Permanent light, 12-240 V AC/DC. For bulb BA15d. Bulb not included. Red K SB-401R 1SFA 616 080 R4011 Green K SB-401G 1SFA 616 080 R4012 Yellow K SB-401Y 1SFA 616 080 R4013 Blue K SB-401L 1SFA 616 080 R4014 Clear K SB-401C 1SFA 616 080 R4018 0.13 0.13 0.13 0.13 0.13 Flashing light, 24 V DC. Xenon tube included. Not changeable. Red K SB-203R 1SFA 616 080 R2031 Green K SB-203G 1SFA 616 080 R2032 Yellow K SB-203Y 1SFA 616 080 R2033 Blue K SB-203L 1SFA 616 080 R2034 Clear K SB-203C 1SFA 616 080 R2038 0.14 0.14 0.14 0.14 0.14 Flashing light, 115 V AC. Xenon tube included. Not changeable. Red K SB-113R 1SFA 616 080 R1131 Green K SB-113G 1SFA 616 080 R1132 Yellow K SB-113Y 1SFA 616 080 R1133 Blue K SB-113L 1SFA 616 080 R1134 Clear K SB-113C 1SFA 616 080 R1138 0.14 0.14 0.14 0.14 0.14 Flashing light, 230 V AC. Xenon tube included. Not changeable. Red K SB-123R 1SFA 616 080 R1231 Green K SB-123G 1SFA 616 080 R1232 Yellow K SB-123Y 1SFA 616 080 R1233 Blue K SB-123L 1SFA 616 080 R1234 Clear K SB-123C 1SFA 616 080 R1238 0.14 0.14 0.14 0.14 0.14 LED Permanent light, 24 V AC/DC. LED included. Not changeable. Red K SB-305R 1SFA 616 080 R3051 Green K SB-305G 1SFA 616 080 R3052 Yellow K SB-305Y 1SFA 616 080 R3053 0.14 0.14 0.14 LED Blinking light, 24 V AC/DC. LED included. Not changeable. Red K SB-306R 1SFA 616 080 R3061 Green K SB-306G 1SFA 616 080 R3062 Yellow K SB-306Y 1SFA 616 080 R3063 0.14 0.14 0.14 LED Rotating light, 24 V AC/DC. LED included. Not changeable. Red K SB-307R 1SFA 616 080 R3071 Green K SB-307G 1SFA 616 080 R3072 Yellow K SB-307Y 1SFA 616 080 R3073 0.14 0.14 0.14 Special parts Anti-twist device K ASB-1000 1SFA 616 087 R1000 Bulbs for Signal Beacons Max 10 W. For permanent light. Bulb BA15d, 52 mm: 12 V, 7 W 24 V, 7 W 115 V, 7 W 220-260 V, 7-10 W 1SFA 616 922 R1018 1SFA 616 922 R1028 1SFA 616 922 R1118 1SFA 616 922 R1148 0.011 0.011 0.011 0.011 Dimension drawings, see p. 59 26 1SFC 261001-EN, Ed. 4 ABB Reset buttons Lens Colour Weight, kg Order Code Without shaft With flush button Red Green Yellow Blue White White with black "R" Black Clear SK 616 204-AA SK 616 204-AB SK 616 204-AC SK 616 204-AD SK 616 204-AE SK 616 404-A SK 616 204-AF SK 616 204-AH 0.020 0.020 0.020 0.020 0.020 0.020 0.020 0.020 SK 616 204-DA SK 616 204-DB SK 616 204-DC SK 616 204-DD SK 616 204-DE SK 616 204-DF SK 616 204-DH 0.021 0.021 0.021 0.021 0.021 0.021 0.021 SK 616 404-B SK 616 404-C SK 616 404-D 0.027 0.027 0.027 5396 0562-1 0.007 With extended button Red Green Yellow Blue White Black Clear With shaft 2) With flush button White with black "R" Black with white "RESET" Blue with black "R" Shaft 30 – 200 mm 2) Dimensions ABB 1) Length of stroke. 2) Can be cut to desired length. 27 1SFC 261001-EN, Ed. 4 Enclosures, non-metallic Degree of protection IP 65 Size Colour top/bottom Order Code 1-seat Grey/black SK 616 801-AA 0.16 1-seat Yellow/black SK 616 801-DA 0.16 2-seat Grey/black SK 616 802-AA 0.21 3-seat Grey/black SK 616 803-AA 0.25 4-seat Grey/black SK 616 804-AA 0.31 6-seat Grey/black SK 616 806-AA 0.40 When ordering Use the order form on page 51. Weight, kg Dimension drawings, see p. 60. • Select operators from page 6-22. • Select contact blocks and lamp blocks for ▼ N.B. Operators for vertically mounted selector switches must be ordered from page 30-31. 3 pos. toggle switches and double pushbuttons are not available for vertical mounting. rear mounting, see page 29. • Accessories, see page 29 and 37. N.B. One spacer per operator has to be ordered if legend plate is not used. 28 1SFC 261001-EN, Ed. 4 ABB Enclosures, non-metallic Accessories Description Type Weight, kg Order Code Contact block for rear mounting 1NO 1NC K CB-10B K CB-01B SK 616 002-A SK 616 002-B 0.013 0.013 Contact block with gold plated contacts for rear mounting 1NO 1NC K CB-10BG K CB-01BG SK 616 008-A SK 616 008-B 0.013 0.013 Lamp block for rear mounting For 2 W, max. 230 V AC and DC bulb, neon lamp or LED. K LB-1B SK 616 003-D 0.015 115 V AC supply voltage. 60 V lamp max. 1.2 W. K LB-2B SK 616 003-E 0.017 230 V AC supply voltage. 130 V lamp max. 2 W. K LB-3B SK 616 003-F 0.020 Protective sleeve To make a rear mounted lamp block screen protected, IP 20. Protective sleeve 5396 0543-1 0.002 Cable gland Black plastic. Threaded outer sleeve. Sealing ring Pr 22.5 included. Pr Pg 22.5 16 28.3 21 Sleeve diameter min. mm Sealing diameter mm 18 24 9 – 15 12 - 20 SK 175 931-AF SK 175 931-AK 0.010 0.017 SK 175 923-3 SK 175 923-4 0.002 0.004 Nut Black plastic. For cable gland above. Pr Pg 22.5 16 28.3 21 Earthing terminal For non-metallic enclosure. 1-seat enclosure has space for one terminal and the others have space for two terminals. Earthing device SK 615 017-A 0.005 Spacer 1mm thick. Needed when legend plates are not used in non-metallic enclosures. Spacer Spacer for Emergency Stop Pushbutton on page 14 SK 615 516-1 0.002 1SFA 616 920 R8045 0.004 SK 616 502-B 0.030 Blanking plug Black non-metallic Impact protection For increased protection against heavy shocks. Impact protection SK 616 590-D 0.010 Adapter plate For Emergency Stop pushbuttons on page 14. For rear mounted contact blocks and lamp blocks. 1SFA 616 920 R8014 ABB 0.007 29 1SFC 261001-EN, Ed. 4 Selector switches, two positions Only for vertically mounted enclosures Handle colour Symbol Type Weight, kg Order Code Short handle – non-illuminated Maintained Red Black K 2SSV1-10R 1SFA 616 220 R1001 K 2SSV1-10B 1SFA 616 220 R1006 0.024 0.024 Red Black K 2SSV2-10R 1SFA 616 221 R1001 K 2SSV2-10B 1SFA 616 221 R1006 0.024 0.024 Momentary, spring return from C to B Red Black K 2SSV3-10R 1SFA 616 222 R1001 K 2SSV3-10B 1SFA 616 222 R1006 0.024 0.024 Short handle – illuminated Maintained Bezel in chrome plastic or metal Replace 1 in the Type K 2SSVX-1 XX Cat. No. 1SFA 616 XXX R 1 XXX Red Green Yellow K 2SSV1-11R 1SFA 616 220 R1101 K 2SSV1-11G 1SFA 616 220 R1102 K 2SSV1-11Y 1SFA 616 220 R1103 0.024 0.024 0.024 Red Green Yellow K 2SSV2-11R 1SFA 616 221 R1101 K 2SSV2-11G 1SFA 616 221 R1102 K 2SSV2-11Y 1SFA 616 221 R1103 0.024 0.024 0.024 Momentary, spring return from C to B Red Green Yellow 2 for chrome plastic bezel K 2SSV3-11R 1SFA 616 222 R1101 K 2SSV3-11G 1SFA 616 222 R1102 K 2SSV3-11Y 1SFA 616 222 R1103 0.024 0.024 0.024 3 for metal bezel Contact blocks and lamp blocks – see page 29 Contact functions Block positions as seen from operator front. Accessories, see p. 29 and 37. Dimension drawings, see p. 56. No contact block in the centre position. Handle position Lower block Upper block A (B) O O C x x O = not influenced (normal state) x = influenced (state changed) 30 1SFC 261001-EN, Ed. 4 ABB Selector switches, three positions Only for vertically mounted enclosures Handle colour Symbol Type Weight, kg Order Code Short handle – non-illuminated Maintained Red Black K 3SSV1-10R K 3SSV1-10B 1SFA 616 230 R1001 1SFA 616 230 R1006 0.024 0.024 Momentary, spring return from A and C to B Red Black K 3SSV2-10R K 3SSV2-10B 1SFA 616 231 R1001 1SFA 616 231 R1006 0.024 0.024 1SFA 616 232 R1001 1SFA 616 232 R1006 0.024 0.024 1SFA 616 230 R1101 1SFA 616 230 R1102 1SFA 616 230 R1103 0.024 0.024 0.024 Momentary, spring return from C to B Red Black K 3SSV3-10R K 3SSV3-10B Short handle – illuminated Maintained Red Green Yellow K 3SSV1-11R K 3SSV1-11G K 3SSV1-11Y Momentary, spring return from A and C to B Red Green Yellow Bezel in chrome plastic or metal Replace 1 in the Type K 2SSVX-1 XX Cat. No. 1SFA 616 XXX R 1 XXX K 3SSV2-11R K 3SSV2-11G K 3SSV2-11Y 1SFA 616 231 R1101 1SFA 616 231 R1102 1SFA 616 231 R1103 0.024 0.024 0.024 1SFA 616 232 R1101 1SFA 616 232 R1102 1SFA 616 232 R1103 0.024 0.024 0.024 Momentary, spring return from C to B Red Green Yellow 2 for chrome plastic bezel 3 for metal bezel K 3SSV3-11R K 3SSV3-11G K 3SSV3-11Y Contact blocks and lamp blocks – see page 29 Contact functions Block positions as seen from operator front. Accessories, see p. 29 and 37. Dimension drawings, see p. 56. No contact block in the centre position. Handle position Lower block Upper block A x O B O O C O x O = not influenced (normal state) x = influenced (state changed) ABB 31 1SFC 261001-EN, Ed. 4 Enclosures, metallic Degree of protection IP 671) Weight, kg Size Colour Order Code 1-seat Grey SK 616 701-AA 0.40 2-seat Grey SK 616 702-AA 0.70 3-seat Grey SK 616 703-AA 0.80 4-seat Grey SK 616 704-AA2) 1.20 6-seat Grey SK 616 706-AA2) 1.40 Select contact blocks for front mounting, see page 35. Select lamp blocks for front mounting, see page 35. Select accessories from page 33, 36-38. 1) Pushbuttons with sealing membrane 32 1SFC 261001-EN, Ed. 4 2) Flanges are not included Dimension drawings, see p. 60. ABB Enclosures, metallic Accessories Description Order Code Weight, kg Cable gland Metal. Threaded outer sleeve. Sealing ring Pr 22.5 (Pg 16) included. Pr Pg Sealing diameter mm 22.5 22.5 22.5 16 16 16 8.5 – 11.5 10.5 – 13.5 12.5 – 15.0 SK 170 7685 SK 170 7686 SK 170 7687 0.040 0.045 0.050 SK 175 0152 0.010 Hexagon nut Metal. Pr 22.5 Pg 16 Blanking plates Without holes. Metal. Black. For 4- and 6-seat enclosures. Note: Gasket not included For flange opening Suitable flange gasket Order Code FL 13 SK 170 4536 SK 172 105-AA 0.110 With holes. Metal. Black. For 4- and 6-seat enclosures. Note: Gasket not included For flange opening Suitable flange gasket Order Code Two threaded holes Pr 22.5 (Pg 16). Hole centre distance 50 mm. FL 13 SK 170 4536 SK 172 105-AD 0.110 Three threaded holes Pr 22.5 (Pg 16). Hole centre distance 38 mm. FL 13 SK 170 4536 SK 172 105-AE 0.100 Four threaded holes Pr 22.5 (Pg 16). Hole centre distance 30 mm. FL 13 SK 170 4536 SK 172 105-AF 0.100 Flange gasket FL 13 SK 170 4536 0.005 Blanking plug Applicable to cover a 22 mm-hole in an enclosure instead of an operator. Gasket and nut included. Black non-metallic SK 616 502-B 0.030 Sealing plug Plastic. Black. For holes Pr 22.5 Pg 16 ABB SK 175 919-3 0.010 33 1SFC 261001-EN, Ed. 4 Assembled stations Fig. See below 1) Legend plate text Left Centre Button/ cap col,our Left Centre Right Right Weight kg Order Code Non-metallic enclosures Degree of protection IP 65, (dependent on the degree of protection of each pushbutton) 1-seat, grey top/black bottom One pushbutton – momentary 1 1 2 2 I I O O – – – – White Green Black Red – – – – One 40 mm emergency stop button – twist release 6 Emerg. Stop (English) – Red – 1SFA 616 811 R1002 1SFA 616 811 R1001 1SFA 616 811 R1004 1SFA 616 811 R1003 0.045 0.045 0.045 0.045 1SFA 616 811 R1016 0.475 1-seat, yellow top/black bottom One 40 mm emergency stop button – twist release 6 – – – – Red – 1SFA 616 821 R1005 0.089 – Green 1SFA 616 812 R1001 0.079 Green 2-seat, grey/black bottom Two pushbuttons – momentary 2,1 O – l Red 3-seat, grey/black bottom Three pushbuttons – momentary 1, 2, 1 1SFA 616 813 R1004 0.112 Two pushbuttons – momentary – pilot lamp in centre position Max 230 V bulb 2, 4, 1 O l l Red Clear Green 1SFA 616 813 R1001 l O ll Green Red 0.116 Two pushbuttons – momentary – pilot lamp in centre position With diode and resistor. For supply voltage 230 V AC and 130V bulb, 5911 086-15 2, 5, 1 O I I Red Clear Green 1SFA 616 813 R1003 0.121 Metallic enclosures 1-seat, grey One pushbutton – momentary Degree of protection IP 66. 1 – I – – Green – 1SFA 616 831 R1001 0.429 One 40 mm mushroom button – maintained – pull release Degree of protection IP 66. 2 Emerg.stop (English) – Red – 1SFA 616 831 R1018 0.452 1 Accessories, see p. 35. Dimension drawings, see p. 60. ) Fig. 1 34 1SFC 261001-EN, Ed. 4 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 ABB Accessories Contact blocks, lamp blocks and holders Max. number of blocks in holder Included blocks Type Weight, kg Order Code Contact blocks and lamp blocks with holder for front mounting For non-illuminated operators 3 3 3 3 3 3 3 3 3 1 NC 1 NO 2 NC 2 NO 3 NC 3 NO 1 NC + 1 NO 2 NC + 1 NO 1 NC + 2 NO K CBH-01 K CBH-10 K CBH-02 K CBH-20 K CBH-03 K CBH-30 K CBH-11 K CBH-12 K CBH-21 1SFA 616 600 R1110 1SFA 616 600 R1101 1SFA 616 600 R1120 1SFA 616 600 R1102 1SFA 616 600 R1130 1SFA 616 600 R1103 1SFA 616 600 R1111 1SFA 616 600 R1121 1SFA 616 600 R1112 0.019 0.019 0.032 0.032 0.045 0.045 0.032 0.045 0.045 K CBH-011 K CBH-101 1SFA 616 600 R1210 1SFA 616 600 R1201 0.034 0.034 K CBH-111 K CBH-021 K CBH-201 1SFA 616 600 R1211 1SFA 616 600 R1220 1SFA 616 600 R1202 0.047 0.047 0.047 For illuminated operators 3 3 3 3 3 1 NC + 1 LB 1 NO + 1 LB 1 NC + 1 NO + 1 LB 2 NC + 1 LB 2 NO + 1 LB Single contact blocks for front mounting1) Contact symbols - NO With gold plated contacts NC - LB 1 NO 1 NC 1 NO 1 NC K CB-10 K CB-01 SK 616 001-A SK 616 001-B 0.013 0.013 K CB-10G K CB-01G SK 616 007-A SK 616 007-B 0.013 0.013 Single lamp blocks for front mounting, BA 9s base1) For 2 W, max. 230 V AC and DC filament bulb, neon bulb or LED. K LB-1 SK 616 003-A 0.015 115 V AC supply voltage. For 60 V filament bulb max. 1.2 W K LB-2 SK 616 003-B 0.017 230 V AC supply voltage. For 130 V filament bulb max. 2 W. K LB-3 SK 616 003-C 0.020 115 V AC and DC supply voltage. For 24 V LED K LB-4 SK 616 003-G 0.017 24 V AC and DC supply voltage. With resistor. Intended for electronic circuits. The resistor limits the making current and protects against disturbances in the electronic circuit. For 24 V filament bulb K LB-5 SK 616 003-M 0.017 Holders Holder for front mounting. For three blocks 1) Contact blocks and lamp blocks for rear mounting, see page 29. ABB K CBH-00 SK 616 013-F 0.006 For lamp blocks with transformer and transformer blocks, see page 36. 35 1SFC 261001-EN, Ed. 4 Accessories Transformer and diode blocks Primary voltage Secondary voltage Type Order Code Weight, kg Transformer with lamp holder for front mounting, BA 9s base For 6 or 24 V filament bulb and 24 V LED. Rated power 1.5 W. Intended to supply a 1.2 W filament bulb. 110 - 127 V AC 6 V AC 1SFA 616 950 R1001 220 - 250 V AC 6 V AC 1SFA 616 950 R1002 380 - 420 V AC 6 V AC 1SFA 616 950 R1003 440 - 480 V AC 6 V AC 1SFA 616 950 R1004 500 - 600 V AC 6 V AC 1SFA 616 950 R1005 110 - 127 V AC 220 - 250 V AC 380 - 420 V AC 440 - 480 V AC 24 V AC 1) 24 V AC 1) 24 V AC 1) 24 V AC 1) 1SFA 616 950 R1011 1SFA 616 950 R1012 1SFA 616 950 R1013 1SFA 616 950 R1014 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 0.095 Transformer block for illuminated operators For 6 or 24 V filament bulb and 24 V LED. Rated power 1.5 W. Intended to supply a 1.2 W filament bulb. 110 – 127 V AC 220 – 240 V AC 380 – 420 V AC 440 – 480 V AC 500 – 600 V AC 6 V AC 6 V AC 6 V AC 6 V AC 6 V AC 1SFA 616 950 R2001 1SFA 616 950 R2002 1SFA 616 950 R2003 1SFA 616 950 R2004 1SFA 616 950 R2005 0.095 0.095 0.095 0.095 0.095 110 – 127 V AC 220 – 240 V AC 380 – 420 V AC 440 – 480 V AC 24 V AC 1) 24 V AC 1) 24 V AC 1) 24 V AC 1) 1SFA 616 950 R2011 1SFA 616 950 R2012 1SFA 616 950 R2013 1SFA 616 950 R2014 0.095 0.095 0.095 0.095 Diode block To be used if several lamps are to be connected to a common lamp-test pushbutton. A diode must be connected in series with each lamp. The diode block snaps onto the lamp block or is placed at the side. Diode block K DB-1001 SK 616 009-A 0.015 Diagram for lamp test 1) Can be used with LED bulb. 36 1SFC 261001-EN, Ed. 4 ABB Accessories Bulbs. BA 9s base. Description Order Code Weight kg Filament bulbs Type of current: AC/DC. A lamp changing tool is required for changing bulb. Rated voltage Rated current Rated output Luminance mcd Service life 6V 12 V 24 V 30 V 48 V 60 V 110 V 130 V 200 mA 100 mA 50 mA 40 mA 42 mA 20 mA 18 mA 15 mA 1.2 W 1.2 W 1.2 W 1.2 W 2W 1.2 W 2W 2W 350 230 280 250 500 190 250 120 10 000 h 10 000 h 10 000 h 10 000 h 6 000 h 5 000 h 7 500 h 7 500 h 5911 086-11 5911 086-12 5911 086-13 5911 086- 4 5911 086- 5 5911 086-14 5911 086- 7 5911 086-15 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 5912 019-1 5912 019-2 5912 019-3 0.003 0.003 0.003 Neon bulbs A lamp changing tool is required for changing bulb. Not to be used together with green, blue or white lamp cap. Rated voltage 110 V 220 V 220 V Rated current Current type Service life 0.8 mA 0.9 mA 1.9 mA AC/DC DC AC 20 000 h 20 000 h 20 000 h LED With one diode chip mounted on a BA 9s base. Choose the same colour for the LED and the lamp cap or else use a clear lamp cap. White LED only with clear lamp cap. At DC the lamp base have to be connected to cathode (-) and the bottom contact to anode (+). Rated voltage Rated current Colour Type of current: (AC)/DC 24 V 24 V 24 V 24 V 24 V 1) 15 mA 15 mA 15 mA 15 mA 15 mA 1) Wavelength Luminance Service life >50 000 hours. Red Green Yellow Blue White 630 nM 525 nM 592 nM 470 nM x=0.31 y=0.32 250 mcd 800 mcd 250 mcd 400 mcd 500 mcd 1SFA 616 921 R2021 1SFA 616 921 R2022 1SFA 616 921 R2023 1SFA 616 921 R2024 1SFA 616 921 R2025 0.005 0.005 0.005 0.005 0.005 At AC the luminance is decreased with 30 % and there is also a slight flickering Type of current: AC Service life 25 000 hours. 110-130 V 110-130 V 110-130 V 110-130 V 110-130 V 4-6 mA 4-6 mA 4-6 mA 4-6 mA 4-6 mA Red Green Yellow Blue White 630 nM 525 nM 592 nM 470 nM x=0.31 y=0.32 25-35 mcd 300-350 mcd 60-90 mcd 130-150 mcd 160-200 mcd 1SFA 616 921R2131 1SFA 616 921R2132 1SFA 616 921R2133 1SFA 616 921R2134 1SFA 616 921R2135 0.005 0.005 0.005 0.005 0.005 1SFA 616 921R2221 1SFA 616 921R2222 1SFA 616 921R2223 1SFA 616 921R2224 1SFA 616 921R2225 0.005 0.005 0.005 0.005 0.005 Type of current: AC Service life 25 000 hours. 230 V 230 V 230 V 230 V 230 V 4 mA 4 mA 4 mA 4 mA 4 mA Red Green Yellow Blue White 630 nM 525 nM 592 nM 470 nM x=0.31 y=0.32 25 mcd 300 mcd 60 mcd 130 mcd 160 mcd Flashing LED A lamp changing tool is required for changing bulb. Choose the same colour for the LED and the lamp cap or else use a clear lamp cap. The lamp base have to be connected to cathode (-) and the bottom contact to anode (+). Type of current DC. Rated voltage Rated current Colour Wave length 24 V 24 V 24 V 25 mA 25 mA 25 mA Red Green Yellow 630 nM 565 nM 585 nM Service life 50 000 h 50 000 h 50 000 h 4950 512-1 4950 512-2 4950 512-3 0.005 0.005 0.005 6880 311-1 0.005 Lamp changing tool For LED and for bulbs. ABB 37 1SFC 261001-EN, Ed. 4 Accessories Miscellaneous Description Order Code Weight kg Mounting tool Used for tightening the nut of the attachment device in confined spaces. 1SFA 616 920 R8015 0.021 Membrane of silicone Of transparent, heat and cold resistant silicon rubber. Does not harden at low temperature. Gives IP 67 degree of protection. When membrane is used, remove the gasket. For operator with: Flush button Extended button Double pushbutton 1SFA 616 920 R8052 1SFA 616 920 R8002 SK 616 503-4 0.002 0.002 0.002 SK 615 512-1 0.002 1SFA 616 920 R8010 0.008 1SFA 616 920 R8001 0.025 Protective ring To prevent inadvertant operation. Not together with legend plate holder. Protective cover For flush button. To prevent inadvertant operation. Not together with legend plate holder. Mounting kit for DIN-rail To be used only with pushbuttons and pilot lights 30 mm adaptors 1) For use when fitting the 22 mm pushbutton range in 30 mm mounting holes. (1.5–4 mm panels) For use with 22 mm Pushbuttons and Switches Black plastic Metal 1SFA 616 920 R8003 1SFA 616 920 R8004 0.012 0.037 For use with 22 mm Emergency Stop Black plastic Metal 1SFA 616 920 R8027 1SFA 616 920 R8028 0.007 0.021 For use with 22 mm Potentiometer, Compact Pilot Light and Buzzer Black plastic 1SFA 616 920 R8029 Metal 1SFA 616 920 R8030 0.010 0.035 1) Legend plates for 30 mm by request. Extra key Ronis 455 (Key code 71) Ronis 421 (Key code 72) Ronis 3433-E (Key code 73) SK 616 021-71 SK 616 021-72 SK 616 021-73 0.007 0.007 0.007 Lock shackle for mushroom button with 30 mm button, twist release Cannot be used in ABB non-metallic enclosure. For 30 mm diameter mushroom button, twist release. Lockable with 4 padlocks when button is in the depressed position. Max. lock yoke diameter 7 mm. SK 615 502-D 0.080 Label sheet For marking of contact blocks at two levels. 2949 1725-1 0.001 2154 373-2 0.001 Guide washer To improve antirotation 38 1SFC 261001-EN, Ed. 4 ABB Accessories Legend plates – Survey Fixed legend plates: Example Toggle switches, two-positions page 43 ● Silver-grey aluminium Toggle switches, three-positions page 43 Pushbuttons page 40 and 44 Legend plates: inserts: Two-position selector switches page 41 Insert plates with customer/selected text/symbols: -See page 49 ● Brushed aluminium on black plastic ● Silver-grey aluminium ● Plastic inserts with one side black and the other white ● Plastic pocket with paper legend slip aluminium ● Grey plastic ● Black plastic page 48-49 Text caps: Extended button Fixed plates with customer-selected text/symbols: -See page 41-44 Fixed plates (black/white) without text: -See page -44 Example ● Silver-grey Flush button Three-position selector switches page 42 Example Pilot light 1. 2. 3. Example me rg e n c y E Special legend plates: page 46-47 Stop ● Yellow aluminium ● Yellow plastic ABB page 45 39 1SFC 261001-EN, Ed. 4 Accessories Legend plates for pushbuttons Silver-grey Aluminium Symbol/text Order Code Weight, kg Engraved fixed legend plates, with symbols1) O l ll ➞ ➞ ➞➞ SK 615 550-61 SK 615 550-62 SK 615 550-63 SK 615 562-12 SK 615 562-18 SK 615 562-27 0.002 0.00 0.002 0.002 0.002 0.002 Engraved fixed legend plates, with text1) English Close Down Emergency stop Fast Forward In Inching Left Lower Off On Open Out Raise Reset Reverse Right Run Slow Start Stop Up SK 615 552-13 SK 615 552-14 SK 615 552-15 SK 615 552-16 SK 615 552-17 SK 615 550-29 SK 615 552-18 SK 615 552-39 SK 615 552-20 SK 615 552-21 SK 615 552-22 SK 615 552-23 SK 615 552-24 SK 615 552-25 SK 615 552-27 SK 615 552-28 SK 615 552-40 SK 615 552-29 SK 615 552-30 SK 615 550-44 SK 615 552-31 SK 615 552-32 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 SK 615 550-12 SK 615 550-15 SK 615 550-16 SK 615 550-18 SK 615 550-19 SK 615 550-20 SK 615 550-27 SK 615 550-28 SK 615 550-29 SK 615 550-32 SK 615 550-33 SK 615 550-34 SK 615 550-35 SK 615 550-37 SK 615 550-38 SK 615 550-39 SK 615 550-44 SK 615 550-45 SK 615 550-46 SK 615 550-47 SK 615 550-48 SK 615 550-49 SK 615 550-50 SK 615 550-51 SK 615 550-52 SK 615 550-53 SK 615 550-54 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 0.002 Swedish Back Drift Fel Fram Framryckning Från Hög Höger In Låg Manöverspänning Minskar Ned Normal Nödstopp Prov Start Stopp Stänger Till Upp Ut Utlösning Vänster Återställning Ökar Öppnar 1) 40 1SFC 261001-EN, Ed. 4 Text height 3 mm. ABB Accessories Legend plates for two-position selector switches Symbol/text Silver-grey Aluminium Silver-Grey Laminated plastic Centre Order Code Order Code Right Weight, kg Engraved fixed legend plates, with symbols1) O I ➞ I II ➞➞ SK 615 550-75 SK 615 550-76 SK 615 562-72 0.002 0.002 0.002 Engraved fixed legend plates, with text1) English H = 39 mm Hand Jog Off Stop Auto Run On Start SK 615 550-71 SK 615 552-52 SK 615 552-53 SK 615 552-55 0.002 0.002 0.002 0.002 SK 615 550-70 SK 615 550-71 SK 615 550-72 SK 615 550-73 SK 615 550-74 0.002 0.002 0.002 0.002 0.002 Swedish Från Hand Låg Prov Stopp Till Auto Hög Drift Start Fixed legend plates with customer-selected text1) Without heading H = 39 mm SK 615 999-1 SK 616 999-21 0.002 SK 616 999-22 0.002 When ordering state (in addition to Cat. No.): – Centre text (max 5 characters) – Right text (max 5 characters) H = 39 mm With heading H = 44.5 mm SK 615 999-2 When ordering state (in addition to Cat. No.): – Heading text (max. 11 characters) – Centre text (max. 5 characters) – Right text (max. 5 characters) H = 44.5 mm 1) ABB Text height 3 mm. Only the initial character is upper case unless other is stated. 41 1SFC 261001-EN, Ed. 4 Accessories Legend plates for three-position selector switches Symbol/text Left Centre Right Silver-grey Aluminium Silver-Grey Laminated plastic Order Code Order Code Weight, kg Engraved fixed legend plates, with symbols1) ❘ ➞ ➞ O O O ❘❘ ➞ ➞➞ SK 615 550-81 SK 615 562-82 SK 615 562-83 0.002 0.002 0.002 Engraved fixed legend plates, with text1) H = 39 mm English Hand Slow O Off Auto Fast SK 615 550-80 SK 615 552-60 0.002 0.002 Auto SK 615 550-80 0.002 Swedish Hand O Fixed legend plates with customer-selected text1) Without heading H = 39 mm SK 615 999-1 SK 616 999-21 0.002 SK 616 999-22 0.002 When ordering state (in addition to Cat. No.): – Left text(max 5 characters) – Centre text (max 5 characters) – Right text (max 5 characters) H = 39 mm With heading H = 44.5 mm – Heading text – Left text – Centre text – Right text H = 44.5 mm 42 1SFC 261001-EN, Ed. 4 1) SK 615 999-2 When ordering state (in addition to Cat. No.): (max. 11 characters) (max. 5 characters) (max. 5 characters) (max. 5 characters) Text height 3 mm. Only the initial character is upper case unless other is stated. ABB Accessories Legend plates for toggle switches Text Silver-grey Aluminium Silver-Grey Laminated plastic Order Code Order Code Weight, kg Fixed legend plates with customer-selected text1) Toggle switches, two positions Two text lines H = 39 mm SK 615 999-3 0.002 When ordering state (in addition to Cat. No.): – Upper text (max. 4 characters) – Lower text (max. 4 characters) Two text lines H = 44,5 mm SK 615 999-4 0.002 When ordering state (in addition to Cat. No.): – Upper text (max. 6 characters) – Lower text (max. 6 characters) Fixed legend plates with customer-selected text1) Toggle switches, three positions Three text lines H = 39 mm SK 615 999-3 SK 616 999-23 0.002 SK 616 999-24 0.002 When ordering state (in addition to Cat. No.): – Upper text (max. 4 characters) – Middle text (max. 3 characters) – Lower text (max. 4 characters) Three text lines H = 44,5 mm SK 615 999-4 When ordering state (in addition to Cat. No.): – Upper text (max. 6 characters) – Middle text (max. 5 characters) – Lower text (max. 6 characters) 1) ABB Text height 3 mm. Only the initial character is upper case unless other is stated. 43 1SFC 261001-EN, Ed. 4 Accessories Legend plates for pushbuttons Silver-grey Aluminium Text Order Code Weight, kg Fixed legend plates (for pushbuttons, mushroom buttons and pilot lights) 1) Standard design without text H = 39 mm For 1-2 text lines H = 39 mm SK 615 540-1 0.002 For 2-3 text lines H = 44.5 mm SK 615 541-1 0.002 With customer-selected text1) For 1 text line H = 39 mm SK 615 999-1 0.002 For 2 text lines H = 44.5 mm SK 615 999-2 0.002 H = 44.5 mm Black/white plastic Symbol/Text Order code Weight, kg Fixed legend plates One side black and the other white. Engraving will give either white or black text. Without text 1) 44 1SFC 261001-EN, Ed. 4 For 1-2 text lines H = 39 mm SK 616 540-2 0.002 For 2-3 text lines H = 44.5 mm SK 616 541-2 0.002 Text height 3 mm. Only the initial character is upper case unless other is stated. ABB Accessories Special legend plates Text Order Code Weight, kg Emergency stop legend plate Black text on a yellow aluminium plate. Quantity per package: 10. Nöd Stopp Emergency Stop Not Aus ARRET D'URGENCE PARADA DE EMERGENCIA SK 615 546-1 SK 615 546-2 SK 615 546-3 SK 615 546-4 SK 615 546-6 0.010 0.010 0.010 0.010 0.010 EMERGENCY STOP NOT AUS ARRET D'URGENCE SK 615 546-13 0.010 Without text SK 615 546-8 0.010 Black text on a yellow plastic plate. Quantity per package: 10. Can be used as yellow background Emergency Stop 1SFA 616 915 R1005 0.003 Legend plate without or with customer-selected text Aluminium. Number of operators 1 2 2 3 3 1 2 ) ) Max. number of characters per line 7 20 24 33 42 Dimensions A L 30.5 40 30.5 40 C 29.6 23.6 60 54 70 64 90 84 110 104 Without text 1) Order Code With text 2) Order Code SK 615 545-1 SK 615 545-2 SK 615 545-3 SK 615 545-4 SK 615 545-5 SK 615 998-1 SK 615 998-2 SK 615 998-3 SK 615 998-4 SK 615 998-5 Weight, kg 0.001 0.001 0.001 0.001 0.001 Quantity per package: 10. When ordering state text and position (upper and lower line). Only the initial character is upper case unless other is stated. Quantity per package: 1. Legend plate for potentiometer Aluminium Design Text Order Code Symbol plate SK 615 562-87 Weight, kg 0.002 29.6 x 44.5 mm ABB 45 1SFC 261001-EN, Ed. 4 Accessories Text caps Text/ Symbol Cap colour 1) Flush button Order Code Extended button Order Code Pilot light Order Code Weight kg Text caps for illuminated pushbuttons and pilot lights Flush or extended button Till White 1SFA 616 901R2020 1SFA 616 902R2020 1SFA 616 903R2020 0.001 Från White 1SFA 616 901R2019 1SFA 616 902R2019 1SFA 616 903R2019 0.001 Start White 1SFA 616 901R2030 1SFA 616 902R2030 1SFA 616 903R2030 0.001 START Green 1SFA 616 906R1042 – – 0.001 Can be turned 90°or 180° Stopp White 1SFA 616 901R2031 1SFA 616 902R2031 1SFA 616 903R2031 0.001 Characters per line One line (line 11): max. 6 Two lines: upper (line 21): max. 5 lower (line 22): max. 5 R White Black 1SFA 616 901R2019 1SFA 616 908R9009 1SFA 616 902R2019 1SFA 616 909R9009 1SFA 616 903R2019 – 0.001 0.001 On White 1SFA 616 901R1020 1SFA 616 902R1020 1SFA 616 903R1020 0.001 ON White Green Black 1SFA 616 901R1039 1SFA 616 906R1039 1SFA 616 908R1039 – – – 1SFA 616 903R1039 – – 0.001 0.001 0.001 Off White 1SFA 616 901R1019 1SFA 616 902R1019 1SFA 616 903R1019 0.001 OFF White Red Black – – – 1SFA 616 902R1040 1SFA 616 905R1040 1SFA 616 909R1040 – – – 0.001 0.001 0.001 Stop White 1SFA 616 901R1031 1SFA 616 902R1031 1SFA 616 903R1031 0.001 STOP Red 1SFA 616 904R1047 1SFA 616 905R1047 – 0.001 Reset White 1SFA 616 901R1025 1SFA 616 902R1025 1SFA 616 903R1025 0.001 Ein White 1SFA 616 901R6020 1SFA 616 902R6020 1SFA 616 903R6020 0.001 Aus White 1SFA 616 901R6019 1SFA 616 902R6019 1SFA 616 903R6019 0.001 Without text White 1SFA 616 901R9000 1SFA 616 902R9000 1SFA 616 903R9000 0.001 With customer selected text2) White 1SFA 616 901R9001 1SFA 616 902R9001 1SFA 616 903R9001 0.001 Pilot light Characters per line One line (line 11): max. 8 Two lines: upper (line 21): max. 8 lower (line 22): max. 8 1) Use only white caps for illuminated pushbuttons and pilot lights 2) When ordering, please state text and position: - one line (middle), max. 6 characters. - two lines (upper and lower), max. 5 or 8 characters. Only the initial character is upper case unless other is stated. Recommended colour combinations of text caps and actuators 46 1SFC 261001-EN, Ed. 4 Text cap colour Actuator Lens colour White White Pilot light Illuminated pushbutton All colours All colours Green, Red, Black, White Non-illuminated pushbutton Clear ABB Accessories Text caps Text/ Symbol Flush button Extended button Can be turned 90°or 180° Flush button Order Code Extended button Order Code Pilot light Order Code Weight kg Text caps for illuminated pushbuttons and pilot lights O White Red Black 1SFA 616 901R9004 1SFA 616 904R9004 1SFA 616 908R9004 1SFA 616 902R9004 1SFA 616 905R9004 – 1SFA 616 903R9004 – – 0.001 0.001 0.001 I White Green Black 1SFA 616 901R9002 1SFA 616 906R9002 1SFA 616 908R9002 1SFA 616 902R9002 – – 1SFA 616 903R9002 – – 0.001 0.001 0.001 II White Green Black 1SFA 616 901R9003 1SFA 616 906R9003 1SFA 616 908R9003 1SFA 616 902R9003 – – 1SFA 616 903R9003 – – 0.001 0.001 0.001 III White Black 1SFA 616 901R9028 1SFA 616 908R9028 1SFA 616 902R9028 – – – 0.001 0.001 + White Green Black 1SFA 616 901R9011 1SFA 616 906R9011 1SFA 616 908R9011 1SFA 616 902R9011 – – – – – 0.001 0.001 0.001 – White Red Black 1SFA 616 901R9012 1SFA 616 904R9012 1SFA 616 908R9012 – – – – – – 0.001 0.001 0.001 White Black 1SFA 616 901R9005 1SFA 616 908R9005 1SFA 616 902R9005 – 1SFA 616 903R9005 – 0.001 0.001 White Black 1SFA 616 901R9014 1SFA 616 908R9014 1SFA 616 902R9014 – – – 0.001 0.001 White Black 1SFA 616 901R9015 1SFA 616 908R9015 1SFA 616 902R9015 – – – 0.001 0.001 White Black 1SFA 616 901R9016 1SFA 616 908R9016 1SFA 616 902R9016 – – – 0.001 0.001 White Black 1SFA 616 901R9017 1SFA 616 908R9017 1SFA 616 902R9017 – – – 0.001 0.001 White 1SFA 616 901R9006 1SFA 616 902R9006 1SFA 616 903R9006 0.001 White Black 1SFA 616 901R9018 1SFA 616 908R9018 1SFA 616 902R9018 – – – 0.001 0.001 White Black 1SFA 616 901R9019 1SFA 616 908R9019 1SFA 616 902R9019 – – – 0.001 0.001 White Black 1SFA 616 901R9020 1SFA 616 908R9020 1SFA 616 902R9020 – – – 0.001 0.001 White Black 1SFA 616 901R9021 1SFA 616 908R9021 1SFA 616 902R9021 – – – 0.001 0.001 White Black 1SFA 616 901R9022 1SFA 616 908R9022 1SFA 616 902R9022 – – – 0.001 0.001 White Black 1SFA 616 901R9023 1SFA 616 908R9023 1SFA 616 902R9023 – – – 0.001 0.001 White Black 1SFA 616 901R9024 1SFA 616 908R9024 1SFA 616 902R9024 – – – 0.001 0.001 White Black 1SFA 616 901R9025 1SFA 616 908R9025 1SFA 616 902R9025 – – – 0.001 0.001 White Black 1SFA 616 901R9026 1SFA 616 908R9026 1SFA 616 902R9026 – – – 0.001 0.001 White Black 1SFA 616 901R9027 1SFA 616 908R9027 1SFA 616 902R9027 – – – 0.001 0.001 Pilot light 1) ABB Cap colour 1) Use only white caps for illuminated pushbuttons and pilot lights. 47 1SFC 261001-EN, Ed. 4 Accessories Special legend plates Text Front ▲ 47 Legend plates with inserts 31 Holder of grey or black plastic. Insert of silver grey aluminium. The insert is securely retained in a pocket and can be removed. The inserts are available without text or with text on one or both sides. 3 mm high text in typeface Helvetica. Weight, kg ▼ ▼ 36 Order Code ▲ ▼ ▼ Rear Legend plate holders Grey Black SK 615 564-1 SK 615 564-8 0.002 0.002 Inserts With text/symbols 48 1SFC 261001-EN, Ed. 4 O I SK 615 570-30 SK 615 582-18 0.001 0.001 English Close On Fast Down Emerg.stop Open Off Slow Up Release SK 615 569-10 SK 615 569-11 SK 615 569-12 SK 615 569-13 SK 615 569-14 0.001 0.001 0.001 0.001 0.001 Cancel In Lower Start Inching Reset Out Raise Stop Jog SK 615 569-15 SK 615 569-16 SK 615 569-17 SK 615 569-18 SK 615 569-19 0.001 0.001 0.001 0.001 0.001 Run Forward Full Reverse SK 615 569-20 SK 615 569-21 0.001 0.001 Swedish Autom.regl Fram Blockering Drift Fel Handregl. Back Deblockering Prov Normal SK 615 570-10 SK 615 570-11 SK 615 570-12 SK 615 570-13 SK 615 570-14 0.001 0.001 0.001 0.001 0.001 Fort Framryckn. Till Full Nollställning Sakta Man.-spänning Från Klart Inställning SK 615 570-15 SK 615 570-16 SK 615 570-17 SK 615 570-18 SK 615 570-19 0.001 0.001 0.001 0.001 0.001 Hög Höger In Ökar Upp Läg Vänster Ut Minskar Ned SK 615 570-20 SK 615 570-21 SK 615 570-22 SK 615 570-23 SK 615 570-24 0.001 0.001 0.001 0.001 0.001 Nödstopp Sakta ned Start Stänger Utlösning Snabbstopp Sakta upp Stopp Öppnar Återställning SK 615 570-25 SK 615 570-26 SK 615 570-27 SK 615 570-28 SK 615 570-29 0.001 0.001 0.001 0.001 0.001 ABB Accessories Special legend plates Front Left Rear Centre Right Left Weight Centre Right Order Code kg Inserts for two-position selector switches Holders – see page 56 Two position. Silver grey aluminium. l ll ➞ ➞➞ SK 615 582-72 0.001 On High Open Auto Stop Slow Jog O Start Fast Run l SK 615 569-30 SK 615 569-31 SK 615 569-32 SK 615 570-51 0.001 0.001 0.001 0.001 Till Auto Hög Stopp O Prov Start l Drift SK 615 570-50 SK 615 570-51 SK 615 570-52 0.001 0.001 0.001 English For two-pos. selector switch Off Low Close Hand Swedish Från Hand Låg Inserts for three-position selector switches Holders – see page 56 Two position. Silver grey aluminium. For three-pos. selector switch ➞ O ➞ ➞ O ➞➞ SK 615 582-82 0.001 Swedish Hand O Auto l O ll SK 615 569-70 0.001 O Off Auto Fast l – O – ll – SK 615 569-70 SK 615 569-71 0.001 0.001 English Hand Slow Inserts with customer-selected text/symbols Holders – see page 56 For two-pos. selector switch Brushed aluminium on black plastic. Engraving on the aluminium side will give black text. Without text With text For three-pos. selector switch SK 615 563-3 SK 616 999-25 0.001 0.001 SK 615 563-1 SK 615 999-5 0.001 0.001 SK 615 563-2 0.001 Silver-grey aluminium. Without text With text Plastic inserts with one side black and the other white Engraving will give either white or black text. Without text When ordering, please state: 1. Text (line 1, 11 or 12, max. 11 characters per line) 2. Left (line 31, max. 5 characters per line) Centre (line 21 or 32, max. 5 characters per line) Right (line 22 or 33, max. 5 characters per line) 3. Black or white side 4. Note: Only the initial character will be upper case unless other is stated. Plastic pocket with paper legend slip Consists of a pocket in which can be placed a typewritten or handwritten legend slip. The plastic pocket is intended for insertion in the legend-plate holder. For indoor application. ABB Plastic pocket SK 615 548-1 Sheet of legend slip 1 sheet=50 legend slip SK 615 548-2 49 1SFC 261001-EN, Ed. 4 Order form – assembled stations Non-metallic enclosures Instructions for order form: Non-metallic enclosed pilot devices 1. Number of enclosures Only one type of enclosure per order form. Specify quantity. 2. Enclosure size 1 1 2 1 2 3 2 1 3 4 1 2 3 4 5 6 The non-metallic enclosures are available in five different sizes, intended for 1 to 6 pushbuttons/pilot lights etc. Specify the number of seats, 1, 2, 3, 4 or 6. Contact blocks, lamp blocks and transformer blocks are snapped on to a built-in DIN rail in the base. In addition to the three positions for each seat, there is further space (=position 4) for using an extra block. See the figure below. Max. no. of blocks= 24 for 6-seat enclosure. Seat 1 1 2 Seat 2 3 4 1 2 Seat 3 3 4 1 2 Seat 4 3 4 1 2 Seat 5 3 4 1 2 Seat 6 3 4 1 2 3 4 ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ 3. Mode of mounting The non-metallic enclosures can be horizontally or vertically mounted. Mark the alternative of your choice with an X. For vertically mounted enclosures legend plates of height=39 mm can be used only. There are also special selector switches available for vertical mounting. See page 30–31. 4. Operators Are selected according to page 6–22. Specify the order number for the required operator. 5.1 Contact block and lamp block Mark the required block with an X. N.B. Normally three markings per seat. Extra blocks in shaded box. 5.2 Transformer block Put in X against your choice. Select according to page 36. Takes up three positions. Place a blanking plug on the mounting hole in the seat that is taken up by a transformer block. Enter the required code letter in the sub-part of the order number. 6. Legend plates Fixed plates and caps can be selected with text according to the legend plate section, page 40–49, with engraved plates or customer-selected texts. Specify the order number only for catalogued options. When ordering customised texts specify the engraving template and the required text for each line/position. N.B. It is not possible to provide double pushbuttons with legend plates. Instead the buttons can be marked. 7. Accessories for non-metallic enclosures See page 29. Specify quantity and order number. 8. Accessories/Special requirements See page 37–38. N.B. filament bulbs, neon bulbs and LEDs are not included. They are to be ordered separately. Specify quantity and order number. 50 1SFC 261001-EN, Ed. 4 ABB Feel free to make copies of this form. It might come in handy at the next ordering occasion. Non-metallic enclosed pilot devices Order form To Ref. From Order no. Issuer, phone Customer 2. Mode of mounting ■ 1. No. of enclosures....................in the design as below 3. Enclosure size 1-seat ■ SK 616 801-AA Date Horizontal 2-seat 3-seat 4-seat 6-seat ■ ■ ■ ■ SK 616 802-AA SK 616 803-AA SK 616 804-AA ■ Rev. Vertical SK 616 806-AA 4. Operators Seat 1 Seat 2 Seat 3 Seat 4 Seat 5 Seat 6 See page 6...22 and 30...31. 1SFA 616 .................... 1SFA 616 ....................... 1SFA 616 ....................... 1SFA 616 ....................... 1SFA 616 ....................... 1SFA 616 ....................... 5.1 Contact blocks, lamp blocks (for rear mounting) Max. 3+1 block/seat Seat 1 ■ = disposable seat for extra block N.B. normally three blocks in all per seat. Seat 2 Seat 3 Seat 4 Seat 5 Seat 6 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Contact block SK 616 002-A ❑ ❑❑ ■ ❑❑❑ ■ ❑ ❑❑ ■ ❑ ❑❑ ■ ❑ ❑❑ ■ ❑ ❑ ❑ ■ SK 616 002-B ❑ ❑❑ ■ ❑ ❑❑ ■ ❑ ❑❑ ■ ❑ ❑❑ ■ ❑ ❑❑ ■ ❑ ❑ ❑ ■ Positions per seat K CB -10B K CB -01B Lamp block SK 616 003-D ❑ ❑ ❑ ❑ ❑ ❑ SK 616 003-E ❑ ❑ ❑ ❑ ❑ ❑ SK 616 003-F ❑ ❑ ❑ ❑ ❑ ❑ K LB -1B K LB -2B K LB -3B 5.2 Transformer block N.B. A transformer block takes up three positions. SK 615 004-....... see page 36. 6. Legend plates Seat 1 Seat 2 Seat 3 Seat 4 Seat 5 Seat 6 Upright Horizontal No. of characters per field ( ) Fixed plates 1) Engraving template, see below Text Heading 1(11) Heading 2(11) Left (5) Upper (4) Centre (5) Centre (3) Right (5) Lower (4) Caps with characters Text 1 line (6)*) Order form 1SFC 16103-55EN CRL/XM 990217 *) 2 lines Upper (5)*) (8) for pilot light Lower (5)*) Fixed plate for: Pushbutton, pilot lights mushroom pushbutton Engraving template A 1) Silver-grey. B 2) Selector switch 2-positions C D 2) Selector switch 3-positions E F 2) Brushed aluminium on black plastic. Yellow for EMERGENCY STOP. 7. Accessories for non-metallic enclosures See page 29. Toggle Toggle 2-positions 3-positions G 2) Only Caps with 1- or 2-line text H for enclosures horizontally mounted. 8. Accessories/Special requirements See page 37. Qty .... Cable gland, incl. nut .... Earthing device ABB 51 1SFC 261001-EN, Ed. 4 Order form – assembled stations Metallic enclosures Instructions for order form: Metal-enclosed pilot devices 1. Number of enclosures Only one type of enclosure per order form. Specify quantity. 2. Enclosure size 1 2 1 2 3 2 1 4 3 3 2 6 1 5 4 The metal enclosures are available in five different sizes, intended for 1 to 6 pushbuttons/pilot lights etc. Specify the number of seats, 1, 2, 3, 4 or 6. Contact blocks, lamp blocks and transformer blocks are front mounted. 5-block holder can be used. 3. Operators Are selected according to page 6-22. Specify the order number for the required operator. 4.1 Contact block and lamp block Mark the required block with an X. N.B. Normally three markings per seat. 4.2 Transformer block Put in X against your choice. Select according to page 36. Takes up three positions. Place a blanking plug on the mounting hole in the seat that is taken up by a transformer block. Enter the required code letter in the sub-part of the order number. 5. Legend plates Fixed plates and caps can be selected with text according to the legend plate section's options with engraved plates or customer-selected texts. Specify the order number only for catalogued options. When ordering customised texts specify the engraving template and the required text for each line/ position. N.B. It is not possible to provide double pushbuttons with legend plates. Instead the buttons can be marked. 6. Accessories for metal-enclosures See page 33. Specify quantity and order number. 7. Accessories/Special requirements See page 37–38. N.B. filament bulbs, neon bulbs and LEDs are not included. They are to be ordered separately. Specify quantity and order number. 52 1SFC 261001-EN, Ed. 4 ABB Feel free to make copies of this form. It might come in handy at the next ordering occasion. Metal-enclosed pilot devices Order form To Ref. Date From Order no. Issuer, phone Customer Rev. 1. No. of enclosures....................in the design as below 2. Enclosure size 1-seat ■ SK 616 701-AA 2-seat 3-seat 4-seat 6-seat ■ ■ ■ ■ SK 616 702-AA SK 616 703-AA SK 616 704-AA SK 616 706-AA 3. Operators Seat 1 Seat 2 Seat 3 Seat 4 Seat 5 Seat 6 See page 6...22. 1SFA 616 ........................ 1SFA 616 ....................... 1SFA 616 ....................... 1SFA 616 ....................... 1SFA 616 ....................... 1SFA 616 ....................... 4.1 Contact block, lamp block (for front mounting) N.B. Max. three blocks in all per seat with 3-block holders.. Seat 1 Seat 2 Seat 3 Seat 4 Seat 5 Seat 6 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 Contact block SK 616 001-A ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ SK 616 001-B ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Lamp block SK 616 003-A ❑ ❑ ❑ ❑ ❑ ❑ SK 616 003-B ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Position 3-block holder K CB -10 K CB -01 K LB -1 K LB -2 SK 616 003-C K LB -3 4.2 Transformer block N.B. A transformer block takes up three positions. SK 615 004-....... see page 36. 5. Legend plates Seat 1 Seat 2 Seat 3 Seat 4 Seat 5 Seat 6 Upright Horizontal No. of characters per field( ) Fixed plates 1) Engraving template, see below Text Heading 1(11) Heading 2(11) Left (5) Upper (4) Centre (5) Centre (3) Right (5) Lower (4) Caps with characters Text 1 line (6)*) 2 lines (8) for pilot light Order form 1SFC 16103-57EN CRL/XM 990217 *) Upper (5)*) Lower (5)*) Fixed plates for: Pushbutton, pilot lights Selector switches mushroom pushbutton 2-positions Engraving template A 1) Silver-grey. B2) C D 2) Selector switches 3-positions E F 2) Toggle Toggle 2-positions 3-positions G Caps with 1- or 2-line text H Brushed aluminium on black plastic. Yellow for EMERGENCY STOP. 2) Only for enclosures horizontally mounted. 6. Accessories for metal enclosures See page 33. 7. Accessories/Special requirements See page 37-38. Qty .... Cable gland, incl. nut .... Earthing device .... Cover plate with n no. of bushings ABB 53 1SFC 261001-EN, Ed. 4 Technical data Approvals The pushbuttons and pilot lights are approved by: – national approval agencies: VDE, UL*) and CSA*) – marine classification: Lloyds, Bureau Veritas, Det Norske Veritas, Germanische Lloyd and Maritime Register of Shipping (Russia). Material and characteristics No ozone depleting substances in the products. Material1) Standards PC PSU PA PBT Zink Light- Rubber alloy Chloro- Nitrile prene IEC 73, 529, 947-5-1, 947-5-5 EN 50 013, 60 947-5-1 VDE 0660 part 2 UL 508 CSA C22.2 No. 14 *) Pushbutton ● ● ● ● ● ● Double pushbutton ● ● ● - - - - ● Mushroom pushbutton, momentary maintained ● ● ● - ● ● - - - ● - ● ● Emergency stop ● - ● ● - - ● ● Potentiometer ● - ● - - - - ● IP 66 IP 66 IP 54 IP 66 IP 54 IP 64 Selector switch ● ● ● - - - - ● Toggle switch ● - ● - - - - ● Pilot light ● - ● - - - - ● Lock in lockable operators - - - - ● - - - Non-metallic enclosure ● - - - - - ● - IP 43 IP 66 IP 54 IP 43 IP 66 IP 65 IP 66 IP 54 IP 65 Metallic enclosure - - - - ● ● - For detail information please contact ABB Degrees of protection Operators Pushbutton with flush or extended button Mushroom pushbutton, momentary Mushroom pushbutton, maintained Emergency stop pushbutton Double pushbutton Reset button Lockable pushbutton and lockable mushroom pushbutton Selector switch Key operated selector switch Toggle switch Pilot lights Buzzer Potentiometer Signal Tower K70 Signal Beacons Electrical functions Contact block and transformer block IP 20 1) Material Characteristics PC Polycarbonate High impact strength, good outdoor resistance. Can withstand light acid solutions, aliphatic hydrocarbons, paraffin, alcohols, animal and vegetable greases. PSU Polysulphone Can withstand high temperatures, acids, basic solutions, alkaline compounds, oils, alcohols. PA Polyamide Can withstand high temperatures, aliphatic, aromatic and chlorinated hydrocarbons, esters, ketone-aldehydes, alcohols and basic solutions. Enclosures Polycarbonate enclosures (Non-metallic) IP 65 Light-alloy enclosures (Metallic) (with sealing membrane) IP 67 54 1SFC 261001-EN, Ed. 4 - PBT Can withstand temperature, aliphatic and aromatic hydrocarbons, acids, basic solutions, alcohols, grease and oils Zinc Good corrosion resistance in inland-, sea and industrial atmosphere. Light-alloy Good corrosion resistance in inland-, sea and industrial atmosphere. ABB Technical data Mechanical life Lamp block Operators Ratings as per IEC 947-5-1 Rated insulation voltage Base Max. permissible power Pushbuttons with flush or extended button, momentary mushroom pushbutton 2 million operations Selector switch, maintained mushroom pushbutton, key operated selector switch and double pushbutton 0.5 million operations Emergency stop pushbutton 0.1 million operations Toggle switch 1 million operations Lockable pushbuttons 0.3 million operations Service life of filament bulb Relative service life, luminous flux and power consumption at different service voltages. It is generally true to say that bulbs for lower voltages give more light and have better vibration-withstand capability than bulbs for higher voltages. Service life Temperature Ambient temperature during operation Exception: All pilot devices with 2 W continuously lit filament bulb Storage temperature 230 V BA 9s 2W a = service life (H) b = luminous flux (lm) c = power (W) Ud = service voltage, V Um= bulb voltage (V) -25 to +70 °C -25 to +40 °C -30 to +85 °C Terminals Plus-minus pozidrive size 2 screw with DIN-washer. Connectable area min. 1 x 0,5 mm2 max. 2 x 2,5 mm2 Recommended torque 0,9 Nm 10 million operations Self cleaning contacts of silver, NC contact has forced breaking. At voltages and currents below 24 V and 5.6 mA two contact blocks in parallel are recommended. As an alternative, gold plated contacts are recommended. Ratings as per UL/CSA, NEMA A 600, Q600 Rated insulation voltage Rated thermal current Rated operational current at 120 V 240 V 480 V 600 V Ratings as per IEC 947-5-1 Rated insulation voltage, Ui Rated thermal current, Ith Rated operational current, Ie utilisation category AC 15, at 120 V 230 V 400 V 690 V Rated operational current, Ie utilisation category DC 13, at 24 V 125 V 250 V Contact resistance 600 V 10 A 6A 3A 1.5 A 1.2 A 690 V 10 A 8A 6A 4A 2A 5A 1.1 A 0.55 A 25 mΩ Max. number of contact blocks per operator 1) Pushbutton, toggle switch 6 Mushroom pushbutton 5 Double pushbutton, selector switch and key operated selector switch, emergency stop pushbutton 4 1) Lamp comparisation Bulb type Contact blocks Mechanical endurance Ud/Um Approx. service life (hours) Shock and vibration immunity High operating temperature Low power Brightness consumption Filament 5000– 10 000 + + + +++ Neon 20 000 ++ +++ +++ + LED 25 000– 50 000 +++ ++ ++ ++ Very good +++ Good ++ Less good + Lens colours suitable for: Red Green Yellow Blue White Clear Filament bulbs LEDs Neon bulbs ● ● ● ● ● ● ● ● ● ● ● ● ● ● Transformer block Suitable for filament bulb 6 or 24 V AC and 1.2 W and LED 24 V. Rated power 1.5 W Rated voltage Ratio, see Accessories page 36 Rated insulation voltage acc. to IEC 70 °C (∆T) Class E The contact blocks can be stacked in max. two levels. Short circuit protection Max. fuse at 1 kA ABB 16 A ordinary 10 A delayed 55 1SFC 261001-EN, Ed. 4 Dimensions Pushbutton Key-lockable pushbutton Mushroom pushbutton R29 Flush Ø29 23 1,5-6 43 Ø60 Ø40 30 56 25,5 25,5 Extended Emergency Stop pushbutton Double pushbutton Selector switch Key-operated selector switch Toggle switch Potentiometer Pilot light Pilot light with transformer Compact Pilot Light Ø29 Ø29 Dimensions in mm. 56 1SFC 261001-EN, Ed. 4 ABB Dimensions Buzzer Transformer block 90 50 30 5 29 Drilling plans for pushbuttons, switches and pilot lights Drilling plan for double pushbutton Drilling plan for 30 mm adaptor 1) 30 2) 1) 55 mm when legend plate H= 44.5 mm is used. 61 mm for mushroom pushbutton with D=60 mm 2) 37 mm when legend plate with insert is used, 30 Mounting on a DIN-rail ABB 57 1SFC 261001-EN, Ed. 4 Dimensions Contact box for cable exit at side Signal Tower K 70 Base for tube, plastic ø 70 ø 70 Rubber seal 15° 2 4. 54 ø 5. 5 15 43 ø PG 11 Base for tube, metal Contact box with magnetic base Base with integrated tube 184 240 56 296 352 32 46 408 PG 11 110 85 ø 25 ø 70 ø 10.5 54 ø 5.5 ø 70 Audible module Bracket 1-sided mounting 69 70 ø 70 Bracket 2-sided mounting Drilling plan for Signal Tower K 70 54 58 1SFC 261001-EN, Ed. 4 ABB Dimensions Signal Beacons K SB Drilling plan for Signal Beacons 39 7 16 32 3 64.5 ø 68 22 Pg29 (ø 37) ø 75 Screw terminal M3 ABB Pull relief 59 1SFC 261001-EN, Ed. 4 Dimensions Dimensions in mm. Enclosures, non-metallic 1 seat 2 seats 3 seats Ø 4.8 (2x) Ø 4.8 (2x) Ø 4.8 (2x) 1) 1) 1) 2) 6 seats 4 seats Ø 4.8 (2x) 23.6 Ø 4.8 (2x) 1) 1) 2) Enclosures, metallic 1 seat 2 or 3 seats 1) Knock-outs in the bottom 2) Both sides identical. Knock-outs, D = 22.5 or 28.6 60 1SFC 261001-EN, Ed. 4 4 or 6 seats ABB ABB 61 1SFC 261001-EN, Ed. 4 ABB agencies and representatives throughout the world Europe AUSTRIA NORWAY ABB Control AS Component Division Kjellstad, Näringssenter N - 3400 LIER Phone : (47) 32858050 Fax : (47) 32858010 POLAND ABB Industrial Components Ltd ul. Marywilska 22 PL - 03 228 WARSAW Phone : (48) 226760400 Fax : (48) 226760440 PORTUGAL ABB Componentes Eléctricos SA Estrada do Casal de Canas Edificio ABB Alfragide P - 2700 AMADORA Phone : (351) 14169200 Fax : (351) 14169250 ROMANIA ABB Ltd Street I. Cimpineanu 16 P.O. Box 1.-871-5th Floor RO - 70100 BUCHAREST Phone : (40) 13300495 Fax : (40) 13300630 ABB Industrie & Gebäudesysteme GmbH (ATIGS) Div. ABB Serienprodukte Wienerbergstrasse 11B P.O. Box 184 A AT - 1810 WIEN Phone : (43) 1601090 Fax : (43) 1601098600 BELGIUM ABB Electro N.V. Hoge Wei 27 B - 1930 ZAVENTEM Phone : (32) 27186311 Fax : (32) 27186666 BULGARIA ABB Ltd 5, Triaditsa street BG - 1040 SOFIA Phone : (359) 29800450 Fax : (359) 29800846 CROATIA ABB Trg. J.F. Kennedya 7 HR - 41000 ZAGREB Phone : (385) 12335355 Fax : (385) 1228836 RUSSIA ABB Industrial & Building Systems 23, Profsoyuznaya street RU - 117 859 MOSCOW Phone : (7) 0951209004 Fax : (7) 0951204490 CZECH REPUBLIC ABB EJF, a.s. Hybesova 30 CZ - 60200 BRNO Phone : (42) 543216742 Fax : (42) 5331489 SLOVAKIA ABB STOTZ Krompachy s.r.o. Hornadska ul. 1 SK - 053 42 KROMPACHY Phone : (42) 965972181 Fax : (42) 956971094 DENMARK ABB Komponent A/S Helgeshoj Allé 8-10 P.O. Box 230 DK - 2630 TAASTRUP Phone : (45) 43595959 Fax : (45) 43595950 SLOVENIA ABB Electrocomponentes SA Dunajska 22 SL- 1000 LJUBLJANA Phone : (386) 611331394 Fax : (386) 611315067 ESTONIA ABB Eesti Pärnu mnt 148 EE - 0013 TALLINN Phone : (372) 6711800 Fax : (372) 6711814 SPAIN ABB Metron S.A. Torrent de l'Olla, 220 E - 08012 BARCELONA Phone : (34) 34842121 Fax : (34) 34842190 FINLAND ABB Control Oy P.O. Box 622 SF - 65101 VAASA Phone : (358) 010224000 Fax: (358) 0102245708 SWEDEN ABB Control AB Saltängsvägen 26 S - 721 61 VASTERAS Phone : (46) 21320700 Fax : (46) 21126001 FRANCE ABB Diffusion S.A. 10, rue Ampère - Z.I., B.P. 114 FR - 69685 CHASSIEU Cedex Phone : (33)4 72221992 Fax : (33) 4 78902758 SWITZERLAND ABB CMC Components Badenerstrasse 790 CH - 8048 ZÜRICH Phone : (41) 14356600 Fax : (41) 14356601 GERMANY ABB SST Eppelheimer Strasse 82 D - 69123 HEIDELBERG Phone : (49) 62217770 Fax : (49) 6221777111 TURKEY ABB Elektrik Sanayi A.S. Yukari Dudullu Imes P.O. Box 3 TR - 81260 UMRANIYE-ITANBUL Phone : (90) 2163652900 Fax : (90) 2163652940 GREECE ABB Trade S.A. 13th Klm National Road Athens-Lamia GR - 144 52 Metamorphossis ATTICA Phone : (30) 12891900 Fax : (30) 12891999 Phone : (44) 203368500 Fax : (44) 203364499 HUNGARY ABB Ltd Vaci ut 152 - 156 P.O. Box 95 HU - 1138 BUDAPEST Phone : (36) 12701555 Fax : (36) 12698723 UNITED KINGDOM ABB Control Ltd Grovelands House Longford Road - Exhall GB - COVENTRY CV7 9ND YUGOSLAVIA Phone : (381) 11344341 Fax : (381) 11341623 ICELAND Johan Ronning HF Sundaborg 15 IS - 105 REYKJAVIK Phone : (354) 5684000 Fax : (354) 5688221 IRELAND ABB Ltd Belgard Road TALLAGHT - DUBLIN 24 Phone : (353) 4057300 Fax : (353) 4057327 ISRAEL S Kahane Agencies. Ltd 1.Haomanviot Str. IL - NETANYA 42160 Phone : (972) 9 8851311 Fax : (972) 9 8851240 ITALY ABB Elettrocondutture S.p.A Viale Dell' Industria 18 I - 200 10 VITTUONE Phone : (39) 2 9034 1 Fax : (39) 2 9034 7609 LATVIA ABB Latvia SIA 15 Krustpils street LV - 1073 RIGA Phone : (371) 2249087 Fax : (371) 9341877 LITHUANIA ABB UAB Lukiskiu 5 LT - 2600 VILNIUS Phone : (370) 822224831 Fax : (370) 822224693 LUXEMBOURG ABB S.A. Zone Industrielle Grasbusch L - 3370 LEUDELANGE Phone : (352) 493116 Fax : (352) 492859 MALTA A. CALLEJA & SONS Ltd 46, Bishop Labini Street P.O. Box 41 MT - B'KARA ABB Componenten BV Lylantse Baan 9 P.O. Box 532 NL - 2908 AM CAPELLE A/D IJSSEL NETHERLANDS ABB Emilijana Josimovica 4 YU - 11000 BELGRAD Africa EGYPT ABB ARAB SA 7dr. Mohamed Kamel Hussein street P.O. Box 197 Heliopolis / CAIRO Phone : (20) 22468001 Fax : (20) 22966776 IVORY COAST ABB S.A. Rue du Canal - Zone 4 P.O. Box 01 BP 1048 ABIDJAN 01 Phone : (225) 354265 Fax : (225) 350414 KENYA ABB Baba Dogo Road, Ruaraka P.O. Box 39120 NAIROBI Phone : (254) 2861570 Fax : (254) 2861574 NIGERIA ABB Industrial avenue, Plot C, Block 1 P.O. Box 21055 IKEJA (LAGOS) Phone : (234) 14937347 Fax : (234) 15875100 MAROCCO Phone : (212) 2310899 : (212) 2311187 Fax : (212) 2311121 Phone : (356) 447 448/449 Fax : (356) 496507 ABB 119, boulevard Emile Zola 9ème étage 21700 CASABLANCA SOUTH AFRICA Phone : (012) 3867088 Fax : (012) 3862422 Phone : (31) 102582250 Fax : (31) 104586559 ABB Installation Materials (Pty) Ltd 86 Tsessebe Crescent P.O. Box 7760 MIDRAND TUNISIA ABB Maghreb Services S.A. Immeuble BADR Les Berges Du Lac P.O. Box 381 TN - 1080 TUNIS Cedex Phone : (27) 116533500 Fax : (27) 116533506 ZIMBABVE ABB Ltd ABB House P.O. Box 2107 88 Rezende Street HARARE Phone : (263) 4773594 Fax : (263) 4753537 Phone and fax numbers do not include the code (0) for local calls in the country - The code between ( ) is the international one. 62 1SFC 261001-EN, Ed. 4 ABB Building Technologies ABB agencies and representatives throughout the world America CANADA ABB Control 3299, Boul. J. B. Deschamps LACHINE QCH8T3E4 QUEBEC H4S 1N6 Phone : (1) 5144203100 Fax : (1) 514203137 U.S.A. ABB Control Inc. 1206 Hatton Road WICHITA FALLS TX 76302 Phone : (940) 3977000 Fax : (940) 3977001 ARGENTINA ABB Tubio Tubío Tucumán S.A. Av. Cordoba 6063 AR - 1427 BUENOS AIRES BRAZIL Phone : (54) 17776116 Fax : (54) 17776116/ 7725907 ABB Ltda Av. dos Autonomistos, 1496-5 Andar 06020-902 Osasco SAO PAULO Phone : (55) 1170889335 Fax : (55) 1170889977 BOLIVIA ABB Ltda Av. 20de Octubre No 2315 P.O. Box 9286 LA PAZ Phone : (591) 327800 Fax : (591) 315623 CHILE ABB SA Vicuna Mackenna 1602 P.O. Box 581-3 SANTIAGO Phone : (56) 25550051 Fax : (56) 25569345 COLOMBIA ABB Ltda Av. Eldorado Carrera 100 n°. 45-A-11 P.O. Box 6195/3984 SANTAFE DÈ BOGOTA Phone : (57) 14178036 Fax : (57) 14134086 ABB S.A Sucur. n° 8 Calle Ulloa 1194 y Mariana de Jesus P.O. Box 17-08-8431 QUITO Phone : (593) 2500645 Fax : (593) 2500650 ABB Tecnical Office Central 69, Avda Norte 148 P.O. Box 1440 SAN SALVADOR Phone : (503) 2986489 Fax : (503) 2242539 ABB Mexico, S.A. de C.V. Boulevard Centro Industrial No 12 Los Reyes Zona Industrial Tlalnepantla, Edo. de Mexico C.P. 54073 MEXICO CITY Phone : (52) 53281400 Fax : (52) 53281663 PERU ABB S.A. Av. Argentina 3120 LIMA Phone : (51) 15610404 Fax : (51) 15613040 VENEZUELA ABB S.A. P.O. Box 6649 - Carmelitas Av. Don Diego Cisneros Edif. ABB Los Ruices CARACAS 1010 A Phone : (58) 22382422 Fax : (58) 22395834 HONG KONG ABB Industrial and Building Systems Ltd 3 Dai Hei Street, Tai Po Industrial Estate Tai Po, N.T. HONG KONG Phone: (852) 29293838 Fax : (852) 29293505 INDIA ABB Ltd. Low Voltage Apparatus Division Plotno 5-6 Peenya Industrial Estate IN - BANGALORE 560052 Phone : (91) 808360962 Fax : (91) 808360349 INDONESIA PT. Abdibangun Buana JI. Cikini Raya 69, Building B Tromol Pos. 3781 JAKARTA 10002 Phone : (62) 213149115 Fax : (62) 213153964 JAPAN ABB Industry K.K. 2-39, Akasaka 5-Chome - Minato-ku Tokyo Central 1284 TOKYO 107 Phone : (81) 355638736 Fax : (81) 335840483 JORDAN Asea Brown Boveri Ltd Al Kheir Center, 2nd fl. P.O. Box 926 098 AMMAN 11110 Phone : (962) 6684067 Fax : (962) 6684167 ECUADOR EL SALVADOR MEXICO KOREA ABB Ltd P.O. Box 6131 8th Floor, Oksan Bldg 157 Samsung-Dong, Kangnam-Ku SEOUL 135-090 Phone : (82) 25282392 Fax : (82) 25283091 KUWAIT ABB Electrical Co. Commercial Area N° 1, Gulf Road Khalid Saleh AL-Ghunaim Building P.O. Box 4275 KW - 13043 SAFAT Phone : (965) 2428626 Fax : (965) 2403139 MALAYSIA ABB Industrial and Building Systems Sdn Bhd No. 8A, Jalan 7/118 B Desa Tun Razak, Cheras 56000 KUALA LUMPUR Phone : (60) 39703398 Fax : (60) 39726888 PAKISTAN Ameejee Valleejee & Sons Campbell street, P.O. Box 51 KARACHI 2 Phone : (92) 21210125 : (92) 21210129 Fax : (92) 21737817 PHILIPPINES ABB Industry KM 20, South Superhighway, Sucat, Paranaque P.O. Box 701 Metro Manila MAKATI Phone : (63) 28244581 Fax : (63) 28195762 SAUDI ARABIA ABB Electrical Industries Ltd P.O. Box 8796 RIYADH 11492 Phone : (966) 12653030 Fax : (966) 12651211 SINGAPORE ABB Industry Pte Ltd 2 Ayer Rajah Crescent SINGAPORE 139 935 Phone : (65) 7765711 Fax : (65) 7780222 TAIWAN ABB Ltd 126 Nanking East Rd, 8F World Building, Section 4 P.O. Box 81-54 TAIPEI Phone : (886) 7316090 Fax : (886) 73355934 THAILAND ABB T&D Ltd 322 Moo, 4 Bangpoo Industrial Estate Soi 6, Sukuhmvit Rd SAMUTPRAKARN 10280 Phone : (66) 23240505 Fax : (66) 23240502 U.A.E. ASEA Brown Boveri Ltd P.O. Box 11070 DUBAI Phone : (971) 4347788 Fax : (971) 4347813 AUSTRALIA ABB Industry Pty Ltd Locked Bag 20 AU - REGENTS PARK NSW 2143 Phone : (61) 297382000 Fax : (61) 297382001 NEW ZEALAND ABB Ltd 133 Central Park Drive P.O. Box 83203, Edmonton Henderson NZ - AUCKLAND Phone : (64) 98371234 Fax : (64) 098372950 Oceania Asia Further information about non listed countries product availability, technical back-up and service, please consult us. ABB Building Technologies 63 1SFC 261001-EN, Ed. 4 Colour selection Colour selection according to IEC 73, edition 4, 1991 IEC 73 specifies colours for pushbuttons and pilot lights and gives recommendations regarding the use of colours. An excerpt from the standards is given below. Colour Pushbutton/Meaning Pilot lights/Meaning RED Emergency Measures required in emergency situations Emergency or danger YELLOW Abnormal. Measures required in abnormal situations Abnormal or warning GREEN Safety Measure to normalize or secure the situation Normal or safety BLUE Prescribed Prescribed or obligatory WHITE, GREY, BLACK No special meaning prescribed No special meaning prescribed Pushbuttons Emergency, even in combination with Off, is to be RED. Stop and Off can be white, grey or black, with preference for BLACK. Red is also allowed. Start and On can be white, grey or black, with preference for WHITE. Green is also allowed. Start and stop in combination can be white, grey or black. Yellow, green or red must not be used. Reset is to be blue, white, grey or black, with preference for BLUE. Reset with stop function can be white, grey or black, with preference for BLACK. Red is also allowed. lluminated pushbuttons The red colour of Emergency must be on the operator itself and is not to be dependent on transmitted light. For other functions, see Pushbuttons. When in doubt, use white (neutral). Pilot lights Pilot lights are to be given colours according to the table above. When in doubt, use white (neutral). 64 1SFC 261001-EN, Ed. 4 ABB Index of Cat. Nos. Order Code Page 2154 373 2949 1725 4950 512 38 38 37 5911 086 5912 019 5396 0543 37 37 29 5396 0562 6880 311 27 37 1SFA 616 070 071 – 079 080, 087 24 25 26 100 – 103 110 – 116 124 – 125 6, 7 11 12 130 – 137 141 – 148 147 – 148 8, 9 8, 10 8, 10 200 – 205 210 – 217 220 – 222 16, 18 17, 19 30 230 – 232 280 – 287 300 – 302 31 20 21 400 – 402 410 500, 501, 504 22 15 13 Order Code 1SFA 616 SK 170 K A70 K ASB K ASI KB K B70 K CB K CBH K CBHS K DB KL K L70 K LB KP K PD ABB Page 25 26 25 22 25 29, 35 22, 35 14 36 22 24 29, 35 6-7 8 - 10 811 – 813 821, 831 901 – 909 34 34 46, 47 915 920 921 45 22, 29, 38 37 922 923 950 26 24 36 4536 7685, 7686, 7687 33 33 Order Code Page SK 616 001 002 003 35 29 29, 35 007 008 009 35 29 36 013 021 204 35 38 27 27 29, 33 38 SK 172 105 33 404 502 503 SK 175 919 923 931 33 29 29 540, 541 590 701 – 704, 706 33 801 – 804, 806 28 999 41, 42, 43, 49 0152 SK 615 017 502, 512 516 29 38 29 540 – 541 545, 546 548 550, 552 562 563 999 44 29 32 44 45 49 40, 41, 42 40, 41, 42, 45 49 564 569, 570, 582 998 510, 511, 513, 514 14 600 22, 35 605 14 Type Page 48 48, 49 45 41, 42, 43, 44 Type K PK K PM.-... K PMT.-..., K PMK.-..., K PMP.-... K S70 K SB K 2SS.-... K 3SS.-... K 2SSK.-..., K 3SSK.-... K 2SSV.-... K 3SSV.-... KT K T70 K TS Page 11 12 13, 14 25 26 16, 18 17, 19 20 30 31 15 25 21 65 1SFC 261001-EN, Ed. 4 Explanation of type designations Explanation of type designation Buzzers, contact blocks, lamp blocks, siren, Signal Beacons etc Example 1: Type K CBH-1110 B CB CBH LB Buzzer Contact Block Contact Block with Holder Lamp Block S70 SB A70 ASI Siren (to K70) Signal Beacon Accessories to K70 AS-Interface Module to K70 Pilot lights, Signal Towers Example 2: Type K L1-100R L1 L2 Pilot Light Head Compact Pilot Light L70 Light element K70 Lens colour: R = Red W = White G = Green B = Black Y = Yellow C = Clear L = Blue U = Grey Operators Example 3: Type K PM1-10Y P PD PK PM PMT PMK PMP 2SS 3SS T TS Example 4: Pushbutton Pushbutton, Double Pushbutton, Key-lockable Pushbutton, Mushroom Pushbutton, Mushroom, Twist release Pushbutton, Mushroom, Key-lockable Pushbutton, Mushroom, Pull release 2-pos. Selector Switch 3-pos. Selector Switch Potentiometer Toggle Switch Button colour/ Lens colour for double pushbuttons R = Red W= White G = Green B = Black Y = Yellow C = Clear U = Grey Y = Blue Type K 2SSK1-10■ PK Pushbutton, Key-lockable 2SSK 2-pos. Selector Switch, Key-lockable 3SSK 3-pos. Selector Switch, Key-lockable K= "Generation" 66 1SFC 261001-EN, Ed. 4 Key code ■ : 1 = 71 2 = 72 3 = 73 K ABB ABB 67 1SFC 261001-EN, Ed. 4 ABB Control AB, SE-721 61 Västerås, Sweden, Telephone +46 21 32 07 00, Telefax +46 21 12 60 01 Catalogue 1SFC 261001-EN, Ed.4 December 2000 ABB Control/XM Printed in June 2001