Accessories

advertisement
Pilot devices, 22 mm
Catalogue 1SFC 261001-EN Edition 4 December 2000
Supersedes Catalogue 1SFC 261001-EN Edition 3 January 2000
Pushbuttons
Switches
Pilot lights
Components
Signal Towers K 70
Signal Beacons K SB
Pushbuttons, selector switches,
toggle switches and pilot lights
A complete range of state-of
the art products
ABB Control has a complete range of pushbuttons,
selector switches and pilot lights of modern design that
are easy to install.
By combining a few basic components a large number of
versions can be built up. They can be ordered in parts
(operator + blocks with holder) or installed in an enclosure.
✔ Lenses and lamp caps have a large area, giving dependable
operation. Pushbuttons and pilot lights are easy to tell
apart.
✔ Pushbuttons, selector switches and toggle switches are
available with three different bezels: black plastic, chrome
plastic or metal.
✔ Terminals protected against inadvertant touching. (IP20)
✔ The contact blocks are colour coded for ease of wiring and
inspection (NO is green, NC is red). The contacts have
silver tips and are self-cleaning to ensure good conductivity
even after long use.
✔ The lamp blocks can take either filament bulb, neon bulb,
buzzer or LED. The bulbs can be changed from the front.
✔ Non-metallic or aluminium enclosures for rear mounting.
Front mounting is available.
✔ A wide assortment of accessories including legend plates,
bulbs, special blocks and enclosures are available.
✔ The design complies with all major international standards.
✔ The terminals on the contact blocks and lamp blocks are
open. Wiring can be done separately before the blocks are
snapped on the operator and holder or to the enclosure
base.
✔ Pushbuttons, pilot lights and selector switches have an integrated spring-loaded tab. Used together with a notched
hole it willl prevent the operator from rotating.
Legend plates
Of plastic or aluminium with
slots that guide the legend
plate and the operator into
the correct position.
Contact block
Single pole with making or
breaking contact.
Operator
Lenses and handles in
several colours.
Illuminated or
non-illuminated.
Sleeve and
tightening nut
The sleeve has
bayonet fit.
Lamp block
Illuminated pushbuttons, selector switches and
pilot lights have a lamp block in the centre
position of the holder.
Holder
Available either for three blocks or five blocks
in one single row. Additional blocks can be
stacked.
Bezels
Pushbuttons, selector switches and toggle switches
with bezel in black plastic, chrome plastic or metal
are available.
Easy to install
The only tool needed is a screwdriver for connecting the wiring.
1. The operator is to be inserted from the front and secured at the
back with a bayonet type sleeve and locking ring.
2
1SFC 261001-EN, Ed. 4
2. The holder is pushed onto the sleeve and secured with a latch.
The contact block/lamp blocks are then snapped on.
ABB
Contents
Pilot devices
Non-illuminated
Illuminated
page
page
Pushbuttons, type K P
6
7
Double pushbuttons, type K PD
8
9-10
Key lockable pushbuttons,
type K PK
11
Mushroom and emergency
stop pushbuttons,
type K PM, K PMT, KPMP, K PMK 12 – 14
Potentiometers, type K T
15
Selector switches,
type K 2SS, K 3SS
16 – 17
Key-operated selector switches,
type K 2SSK, K 3SSK
20
Toggle switches, type K TS
21
Pilot lights, type K L
22
Buzzers, type K B
22
12, 14
18–19
Signal Towers, type K 70
23 – 25
Signal Beacons, type K SB
26
Reset buttons
27
Enclosures and assembled stations
ABB
Non-metallic enclosures
Metallic enclosures
Assembled stations
28
32
34
Accessories
Blocks
Bulbs
Legend plates
35
37
39
Miscellaneous
Order forms
Technical data
Dimensions
Colour selection
Index of Order Codes
ABB agencies and representatives
Explanation of type designations
50
54
56
64
65
62
66
3
1SFC 261001-EN, Ed. 4
Selection Guide
Pushbuttons
Double pushbuttons
Selector switches
Mushrooms
Key-lockable
pushbuttons
Pilot-lights
4
1SFC 261001-EN, Ed. 4
Contact block combinations
Non-illuminated/momentary
Non-illuminated/maintained
Illuminated
Contact block combinations
Non-illuminated
Illuminated
Contact block combinations
Non-illuminated
Illuminated
Contact block/
lamp block combinations
Contact block combinations
Lamp block combinations
E-stop
Toggle switches
Contact block/lamp block
combinations with safety holder
Contact block combinations
Compact pilot light
ABB
Selection Guide
Panel holes
Accessories
Legend plates
Text caps
Sealing membrane
Ø 30
Ø 22.5
Guard
Hole
adaptor
panel
1.5 – 4 mm
panel
1.5 – 6 mm
For
For
Not together with
flush
extended legend plate
button button
holder
Not together
with legend
plate holder
Transformers
Accessories
Sealing membrane
Accessories
Legend plates
Accessories
Legend plates
me
rg e n c
Stop
Components
y
E
Shackle
Not together
with
legend plate.
For 30 mm knob with twist
release only.
Potentiometers
Reset buttons
Buzzers
Accessories
Legend plates
Accessories
Legend plates
ABB
Text cap
5
1SFC 261001-EN, Ed. 4
Note: Both operator and
contact block(s) must be
ordered to get a complete
pilot device
Pushbuttons, non-illuminated
Black plastic bezel
Order Code
Weight
kg
K P1-10R
K P1-10G
K P1-10Y
K P1-10L
K P1-10W
K P1-10B
K P1-10C
1SFA 616 100 R1001
1SFA 616 100 R1002
1SFA 616 100 R1003
1SFA 616 100 R1004
1SFA 616 100 R1005
1SFA 616 100 R1006
1SFA 616 100 R1008
0.016
0.016
0.016
0.016
0.016
0.016
0.016
K P2-10R
K P2-10G
K P2-10Y
K P2-10L
K P2-10W
K P2-10B
1SFA 616 101 R1001
1SFA 616 101 R1002
1SFA 616 101 R1003
1SFA 616 101 R1004
1SFA 616 101 R1005
1SFA 616 101 R1006
0.016
0.016
0.016
0.016
0.016
0.016
K P3-10R
K P3-10G
K P3-10Y
K P3-10L
K P3-10W
K P3-10B
K P3-10C
1SFA 616 102 R1001
1SFA 616 102 R1002
1SFA 616 102 R1003
1SFA 616 102 R1004
1SFA 616 102 R1005
1SFA 616 102 R1006
1SFA 616 102 R1008
0.016
0.016
0.016
0.016
0.016
0.016
0.016
K P4-10R
K P4-10G
K P4-10Y
K P4-10L
K P4-10W
K P4-10B
1SFA 616 103 R1001
1SFA 616 103 R1002
1SFA 616 103 R1003
1SFA 616 103 R1004
1SFA 616 103 R1005
1SFA 616 103 R1006
0.016
0.016
0.016
0.016
0.016
0.016
Type
Order Code
Weight
kg
Type
Operator with flush button
Momentary
Button colour:
Red
Green
Yellow
Blue
White
Black
Clear
Maintained 1)
Button colour:
Red
Green
Yellow
Blue
White
Black
Operator with extended button
Momentary
Button colour:
Red
Green
Yellow
Blue
White
Black
Clear
Bezel in chrome plastic or metal
Maintained 1)
Replace 1 in the:
Button colour:
Type K PX-1 0X
Cat. No. 1SFA 616 XXX R 1 XXX
2 for chrome plastic bezel
3 for metal bezel
Red
Green
Yellow
Blue
White
Black
Blocks
Contact blocks and holder
1 NO with holder
1 NC with holder
2 NO with holder
2 NC with holder
1 NO +1 NC with holder
K CBH-10
K CBH-01
K CBH-20
K CBH-02
K CBH-11
1SFA 616 600 R1101
1SFA 616 600 R1110
1SFA 616 600 R1102
1SFA 616 600 R1120
1SFA 616 600 R1111
0.019
0.019
0.032
0.032
0.032
1 NO without holder
1 NC without holder
K CB-10
K CB-01
SK 616 001-A
SK 616 001-B
0.013
0.013
Holder for 3 blocks
K CBH-00
SK 616 013-F
0.006
NO
NC
1)
6
1SFC 261001-EN, Ed. 4
No contact block in the centre
position.
Accessories, see p. 35.
Dimension drawings, see p. 56.
ABB
Note: Both operator and
contact block(s) /lamp block
must be ordered to get
a complete pilot device
Pushbuttons, illuminated
Black plastic bezel
Order Code
Weight
kg
K P1-11R
K P1-11G
K P1-11Y
K P1-11L
K P1-11W
K P1-11C
1SFA 616 100 R1101
1SFA 616 100 R1102
1SFA 616 100 R1103
1SFA 616 100 R1104
1SFA 616 100 R1105
1SFA 616 100 R1108
0.016
0.016
0.016
0.016
0.016
0.016
K P2-11R
K P2-11G
K P2-11Y
K P2-11L
K P2-11W
K P2-11C
1SFA 616 101 R1101
1SFA 616 101 R1102
1SFA 616 101 R1103
1SFA 616 101 R1104
1SFA 616 101 R1105
1SFA 616 101 R1108
0.016
0.016
0.016
0.016
0.016
0.016
K P3-11R
K P3-11G
K P3-11Y
K P3-11L
K P3-11W
K P3-11C
1SFA 616 102 R1101
1SFA 616 102 R1102
1SFA 616 102 R1103
1SFA 616 102 R1104
1SFA 616 102 R1105
1SFA 616 102 R1108
0.016
0.016
0.016
0.016
0.016
0.016
Button colour: Red
Green
Yellow
Blue
White
Clear
K P4-11R
K P4-11G
K P4-11Y
K P4-11L
K P4-11W
K P4-11C
1SFA 616 103 R1101
1SFA 616 103 R1102
1SFA 616 103 R1103
1SFA 616 103 R1104
1SFA 616 103 R1105
1SFA 616 103 R1108
0.016
0.016
0.016
0.016
0.016
0.016
Blocks
Type
Order Code
Weight
kg
Type
Operator with flush button
Momentary 1)
Button colour: Red
Green
Yellow
Blue
White
Clear
Maintained 1)
Button colour: Red
Green
Yellow
Blue
White
Clear
Operator with extended button
Momentary 1)
Button colour: Red
Green
Yellow
Blue
White
Clear
Maintained 1)
Bezel in chrome plastic or metal
Replace 1 in the:
Type K PX-1 0X
Cat. No. 1SFA 616 XXX R 1 XXX
2 for chrome plastic bezel
3 for metal bezel
Contact blocks, lamp blocks and holder
NO
LB
NC
1)
ABB
1 NO + 1 LB with holder2)
1 NC + 1 LB with holder2)
2 NO + 1 LB with holder2)
2 NC + 1 LB with holder2)
1 NO +1 NC + 1 LB with holder2)
K CBH-101
K CBH-011
K CBH-201
K CBH-021
K CBH-111
1SFA 616 600 R1201
1SFA 616 600 R1210
1SFA 616 600 R1202
1SFA 616 600 R1220
1SFA 616 600 R1211
0.034
0.034
0.047
0.047
0.047
1 NO without holder
1 NC without holder
K CB-10
K CB-01
SK 616 001-A
SK 616 001-B
0.013
0.013
Lampblock for 2 W, max. 230 V AC
and DC bulb, neon bulb or LED
K LB-1
SK 616 003-A
0.015
Holder for 3 blocks
K CBH-00
SK 616 013-F
0.006
No contact block in the centre
position.
2)
Lamp block for max. 230 V AC/
DC. Bulb not included.
For other lamp blocks see p 35.
Accessories, see p. 35.
Dimension drawings, see p. 56.
7
1SFC 261001-EN, Ed. 4
Note: Both operator and
contact block(s) must be
ordered to get a complete
pilot device
Double pushbuttons, non-illuminated
Upper button
Colour
Text
Lower button
Colour
Text
Type
Order Code
Weight
kg
Operator with flush buttons 1)
Green
no text
I
ON
START
Red
no text
O
OFF
STOP
K PD1-11B
K PD2-11B
K PD3-11B
K PD4-11B
1SFA 616 130 R1106
1SFA 616 131 R1106
1SFA 616 132 R1106
1SFA 616 133 R1106
0.025
0.025
0.025
0.025
White
no text
I
ON
START
Black
no text
O
OFF
STOP
K PD5-11B
K PD6-11B
K PD7-11B
K PD8-11B
1SFA 616 134 R1106
1SFA 616 135 R1106
1SFA 616 136 R1106
1SFA 616 137 R1106
0.025
0.025
0.025
0.025
Lens colour
= black
Operator with extended lower button 1)
Green
no text
I
ON
START
Red
no text
O
OFF
STOP
K PD12-11B
K PD13-11B
K PD14-11B
K PD15-11B
1SFA 616 141 R1106
1SFA 616 142 R1106
1SFA 616 143 R1106
1SFA 616 144 R1106
0.025
0.025
0.025
0.025
White
no text
I
ON
START
Black
no text
O
OFF
STOP
K PD16-11B
K PD17-11B
K PD18-11B
K PD19-11B
1SFA 616 145 R1106
1SFA 616 146 R1106
1SFA 616 147 R1106
1SFA 616 148 R1106
0.025
0.025
0.025
0.025
Lens colour
= black
Blocks
Type
Order Code
Weight
kg
Contact blocks and holder
2 NO with holder
2 NC with holder
1 NO +1 NC with holder
K CBH-20
K CBH-02
K CBH-11
1SFA 616 600 R1102
1SFA 616 600 R1120
1SFA 616 600 R1111
0.032
0.032
0.032
1 NO without holder
1 NC without holder
K CB-10
K CB-01
SK 616 001-A
SK 616 001-B
0.013
0.013
Holder for 3 blocks
K CBH-00
SK 616 013-F
0.006
NO
NC
1)
8
1SFC 261001-EN, Ed. 4
No contact block in the centre
position.
Accessories, see p. 35.
Dimension drawings, see p. 56.
ABB
Note: Both operator and
contact block(s) /lamp block
must be ordered to get
a complete pilot device
Double pushbuttons, illuminated
Upper button
Colour
Text
Lower button
Colour
Text
Type
Order Code
Weight
kg
Operator with flush buttons 1)
Red lens
Lens colours
- red
- green
- yellow
- clear
Green
no text
I
ON
START
Red
no text
O
OFF
STOP
K PD1-11R
K PD2-11R
K PD3-11R
K PD4-11R
1SFA 616 130 R1101
1SFA 616 131 R1101
1SFA 616 132 R1101
1SFA 616 133 R1101
0.025
0.025
0.025
0.025
White
no text
I
ON
START
Black
no text
O
OFF
STOP
K PD5-11R
K PD6-11R
K PD7-11R
K PD8-11R
1SFA 616 134 R1101
1SFA 616 135 R1101
1SFA 616 136 R1101
1SFA 616 137 R1101
0.025
0.025
0.025
0.025
Green lens
Green
no text
I
ON
START
Red
no text
O
OFF
STOP
K PD1-11G
K PD2-11G
K PD3-11G
K PD4-11G
1SFA 616 130 R1102
1SFA 616 131 R1102
1SFA 616 132 R1102
1SFA 616 133 R1102
0.025
0.025
0.025
0.025
White
no text
I
ON
START
Black
no text
O
OFF
STOP
K PD5-11G
K PD6-11G
K PD7-11G
K PD8-11G
1SFA 616 134 R1102
1SFA 616 135 R1102
1SFA 616 136 R1102
1SFA 616 137 R1102
0.025
0.025
0.025
0.025
Yellow lens
Green
no text
I
ON
START
Red
no text
O
OFF
STOP
K PD1-11Y
K PD2-11Y
K PD3-11Y
K PD4-11Y
1SFA 616 130 R1103
1SFA 616 131 R1103
1SFA 616 132 R1103
1SFA 616 133 R1103
0.025
0.025
0.025
0.025
White
no text
I
ON
START
Black
no text
O
OFF
STOP
KPD5-11Y
KPD6-11Y
KPD7-11Y
KPD8-11Y
1SFA 616 134 R1103
1SFA 616 135 R1103
1SFA 616 136 R1103
1SFA 616 137 R1103
0.025
0.025
0.025
0.025
Clear lens
Green
no text
I
ON
START
Red
no text
O
OFF
STOP
K PD1-11C
K PD2-11C
K PD3-11C
K PD4-11C
1SFA 616 130 R1108
1SFA 616 131 R1108
1SFA 616 132 R1108
1SFA 616 133 R1108
0.025
0.025
0.025
0.025
White
no text
I
ON
START
Black
no text
O
OFF
STOP
K PD5-11C
K PD6-11C
K PD7-11C
K PD8-11C
1SFA 616 134 R1108
1SFA 616 135 R1108
1SFA 616 136 R1108
1SFA 616 137 R1108
0.025
0.025
0.025
0.025
Type
Order Code
Weight
kg
Blocks
Contact blocks, lamp blocks and holder
NO
LB
NC
1)
ABB
2 NO + 1 LB with holder 2)
2 NC + 1 LB with holder 2)
1 NO +1 NC + 1 LB with holder 2)
K CBH-201
K CBH-021
K CBH-111
1SFA 616 600 R1202
1SFA 616 600 R1220
1SFA 616 600 R1211
0.047
0.047
0.047
1 NO without holder
1 NC without holder
K CB-10
K CB-01
SK 616 001-A
SK 616 001-B
0.013
0.013
Lamp block for 2 W, max. 230 V AC
and DC bulb, neon bulb or LED
K LB-1
SK 616 003-A
0.015
Holder for 3 blocks
K CBH-00
SK 616 013-F
0.006
No contact block in the centre
position.
2)
Lamp block for max. 230 V AC/
DC. Bulb not included.
For other lamp blocks see p 35.
Accessories, see p. 35.
Dimension drawings, see p. 56.
9
1SFC 261001-EN, Ed. 4
Note: Both operator and
contact block(s) /lamp block
must be ordered to get
a complete pilot device
Double pushbuttons, illuminated
Upper button
Colour
Text
Lower button
Colour
Text
Type
Weight
kg
Order Code
Operator with extended lower button buttons 1)
Red lens
Lens colours
- red
- green
- yellow
- clear
Green
no text
I
ON
START
Red
no text
O
OFF
STOP
K PD12-11R
K PD13-11R
K PD14-11R
K PD15-11R
1SFA 616 141 R1101
1SFA 616 142 R1101
1SFA 616 143 R1101
1SFA 616 144 R1101
0.025
0.025
0.025
0.025
White
no text
I
ON
START
Black
no text
O
OFF
STOP
K PD16-11R
K PD17-11R
K PD18-11R
K PD19-11R
1SFA 616 145 R1101
1SFA 616 146 R1101
1SFA 616 147 R1101
1SFA 616 148 R1101
0.025
0.025
0.025
0.025
Green lens
Green
no text
I
ON
START
Red
no text
O
OFF
STOP
K PD12-11G
K PD13-11G
K PD14-11G
K PD15-11G
1SFA 616 141 R1102
1SFA 616 142 R1102
1SFA 616 143 R1102
1SFA 616 144 R1102
0.025
0.025
0.025
0.025
White
no text
I
ON
START
Black
no text
O
OFF
STOP
K PD16-11G
K PD17-11G
K PD18-11G
K PD19-11G
1SFA 616 145 R1102
1SFA 616 146 R1102
1SFA 616 147 R1102
1SFA 616 148 R1102
0.025
0.025
0.025
0.025
Yellow lens
Green
no text
I
ON
START
Red
no text
O
OFF
STOP
K PD12-11Y
K PD13-11Y
K PD14-11Y
K PD15-11Y
1SFA 616 141 R1103
1SFA 616 142 R1103
1SFA 616 143 R1103
1SFA 616 144 R1103
0.025
0.025
0.025
0.025
White
no text
I
ON
START
Black
no text
O
OFF
STOP
K PD16-11Y
K PD17-11Y
K PD18-11Y
K PD19-11Y
1SFA 616 145 R1103
1SFA 616 146 R1103
1SFA 616 147 R1103
1SFA 616 148 R1103
0.025
0.025
0.025
0.025
Clear lens
Green
no text
I
ON
START
Red
no text
O
OFF
STOP
K PD12-11C
K PD13-11C
K PD14-11C
K PD15-11C
1SFA 616 141 R1108
1SFA 616 142 R1108
1SFA 616 143 R1108
1SFA 616 144 R1108
0.025
0.025
0.025
0.025
White
no text
I
ON
START
Black
no text
O
OFF
STOP
K PD16-11C
K PD17-11C
K PD18-11C
K PD19-11C
1SFA 616 145 R1108
1SFA 616 146 R1108
1SFA 616 147 R1108
1SFA 616 148 R1108
0.025
0.025
0.025
0.025
Type
Order Code
Weight
kg
Blocks
Contact blocks, lamp block and holder
NO
LB
NC
1)
10
1SFC 261001-EN, Ed. 4
2 NO + 1 LB with holder 2)
2 NC + 1 LB with holder 2)
1 NO +1 NC + 1 LB with holder 2)
K CBH-201
K CBH-021
K CBH-111
1SFA 616 600 R1202
1SFA 616 600 R1220
1SFA 616 600 R1211
0.047
0.047
0.047
1 NO without holder
1 NC without holder
K CB-10
K CB-02
SK 616 001-A
SK 616 001-B
0.013
0.013
Lamp block for 2 W, max. 230 V AC
and DC bulb, neon bulb or LED
K LB-1
SK 616 003-A
0.015
Holder for 3 blocks
K CBH-00
SK 616 013-F
0.006
No contact block in the centre
position.
2)
Lamp block for max. 230 V AC/
DC. Bulb not included.
For other lamp blocks see p 35.
Accessories, see p. 35.
Dimension drawings, see p. 56.
ABB
Note: Both operator and
contact block(s) must be
ordered to get a complete
pilot device
Key-lockable pushbuttons
Type
Weight
kg
Order Code
Maintained
Locks, when depressed, can only be released with the key
Key removable in both locked and unlocked position
Ronis 455 (Key code 71)
Ronis 421 (Key code 72)
Ronis 3433-E (Key code 73)
K PK1-101
K PK1-102
K PK1-103
1SFA 616 110 R1001
1SFA 616 110 R1002
1SFA 616 110 R1003
0.059
0.059
0.059
Momentary
Can be operated without key when unlocked
Key removable in both locked and unlocked position
Key-lockable in non-depressed position
Ronis 455 (Key code 71)
K PK2-101
Ronis 421 (Key code 72)
K PK2-102
Ronis 3433-E (Key code 73)
K PK2-103
1SFA 616 111 R1001
1SFA 616 111 R1002
1SFA 616 111 R1003
0.059
0.059
0.059
Key-lockable in depressed position
Ronis 455 (Key code 71)
K PK3-101
Ronis 421 (Key code 72)
K PK3-102
Ronis 3433-E (Key code 73)
K PK3-103
1SFA 616 112 R1001
1SFA 616 112 R1002
1SFA 616 112 R1003
0.059
0.059
0.059
Key-lockable in both non-depressed and depressed position
Ronis 455 (Key code 71)
K PK4-101
1SFA 616 113 R1001
Ronis 421 (Key code 72)
K PK4-102
1SFA 616 113 R1002
Ronis 3433-E (Key code 73)
K PK4-103
1SFA 616 113 R1003
0.059
0.059
0.059
Can only be operated with the key
Key removable in locked position
The key-lockable pushbuttons
are delivered with two keys.
Other key codes
On request
Key-lockable in non-depressed position
Ronis 455 (Key code 71)
K PK5-101
Ronis 421 (Key code 72)
K PK5-102
Ronis 3433-E (Key code 73)
K PK5-103
1SFA 616 114 R1001
1SFA 616 114 R1002
1SFA 616 114 R1003
0.059
0.059
0.059
Key-lockable in depressed position
Ronis 455 (Key code 71)
K PK6-101
Ronis 421 (Key code 72)
K PK6-102
Ronis 3433-E (Key code 73)
K PK6-103
1SFA 616 115 R1001
1SFA 616 115 R1002
1SFA 616 115 R1003
0.059
0.059
0.059
Key-lockable in both non-depressed and depressed position
Ronis 455 (Key code 71)
K PK7-101
1SFA 616 116 R1001
Ronis 421 (Key code 72)
K PK7-102
1SFA 616 116 R1002
Ronis 3433-E (Key code 73)
K PK7-103
1SFA 616 116 R1003
0.059
0.059
0.059
Blocks
Weight
kg
Type
Order Code
Contact blocks, lamp block and holder
NO
NC
1 NO with holder
1 NC with holder
2 NO with holder
2 NC with holder
1 NO +1 NC with holder
K CBH-10
K CBH-01
K CBH-20
K CBH-02
K CBH-11
1SFA 616 600 R1101
1SFA 616 600 R1110
1SFA 616 600 R1102
1SFA 616 600 R1120
1SFA 616 600 R1111
0.019
0.019
0.032
0,032
0.032
1 NO without holder
1 NC without holder
K CB-10
K CB-01
SK 616 001-A
SK 616 001-B
0.013
0.013
Holder for 3 blocks
K CBH-00
SK 616 013-F
0.006
Accessories, see p. 35.
Dimension drawings, see p. 56.
ABB
11
1SFC 261001-EN, Ed. 4
Note: Both operator and
contact block(s) /lamp block
must be ordered to get
a complete pilot device
Mushroom pushbuttons, momentary
Non-illuminated and illuminated
Operator
material
Button
colour
Type
Order Code
Weight
kg
Non-illuminated operators
Ø 40 mm
Plastic
Red
Yellow
Black
K PM1-10R
K PM1-10Y
K PM1-10B
1SFA 616 124 R1001
1SFA 616 124 R1003
1SFA 616 124 R1006
0.039
0.039
0.039
Red
Yellow
Black
K PM2-10R
K PM2-10Y
K PM2-10B
1SFA 616 125 R1001
1SFA 616 125 R1003
1SFA 616 125 R1006
0.039
0.039
0.039
Red
Yellow
K PM1-11R
K PM1-11Y
1SFA 616 124 R1101
1SFA 616 124 R1103
0.039
0.039
Red
Yellow
K PM2-11R
K PM2-11Y
1SFA 616 125 R1101
1SFA 616 125 R1103
0.039
0.039
Type
Order Code
Weight
kg
Ø 60 mm
Plastic
Illuminated operators 1)
Ø 40 mm
Plastic
Ø 60 mm
Plastic
Bezel in chrome plastic or metal
Replace 1 in the:
Type K PMX-1 XX
Cat. No. 1SFA 616 XXX R 1 XXX
2 for chrome plastic bezel
3 for metal bezel
Blocks
Contact blocks, lamp block and holder
NO
1 NO with holder
1 NC with holder
2 NO with holder
2 NC with holder
1 NO +1 NC with holder
1 NO + 1 LB with holder 2)
1 NC + 1 LB with holder 2)
2 NO + 1 LB with holder 2)
2 NC + 1 LB with holder 2)
1 NO +1 NC + 1 LB with holder 2)
K CBH-10
K CBH-01
K CBH-20
K CBH-02
K CBH-11
K CBH-101
K CBH-011
K CBH-201
K CBH-021
K CBH-111
1SFA 616 600 R1101
1SFA 616 600 R1110
1SFA 616 600 R1102
1SFA 616 600 R1120
1SFA 616 600 R1111
1SFA 616 600 R1201
1SFA 616 600 R1210
1SFA 616 600 R1202
1SFA 616 600 R1220
1SFA 616 600 R1211
0.019
0.019
0.032
0.032
0.032
0.019
0.019
0.047
0.047
0.047
1 NO without holder
1 NC without holder
K CB-10
K CB-01
SK 616 001-A
SK 616 001-B
0.013
0.013
1 LB For max 230 V AC/DC bulb, neon
bulb or LED
K LB-1
SK 616 003-A
0.015
Holder for 3 blocks
SK 616 013-F
0.006
K CBH-00
LB
NC
1)
12
1SFC 261001-EN, Ed. 4
No contact block in the centre
position.
2)
Lamp block for max. 230 V AC/
DC. Bulb not included.
For other lamp blocks see p 29.
Accessories, see p. 35.
Dimension drawings, see p. 56.
ABB
Note: Both operator and
contact block(s) must be
ordered to get a complete
pilot device
Mushroom pushbuttons
Maintained.
Operator
material
Button
colour
Type
Order Code
Weight
kg
Non-illuminated operators
Operator Ø 30 mm
Twist release
Plastic
Red
K PMT1-10R
1SFA 616 500 R1001
0.039
Black
K PMT1-10B
1SFA 616 500 R1006
0.039
Red
K PMP1-10R
1SFA 616 501 R1001
0.039
Black
K PMP1-10B
1SFA 616 501 R1006
0.039
Pull release
Plastic
Operator Ø 40 mm
Key release (key code 71, Ronis 455)
Plastic
Red
K PMK2-10R
1SFA 616 504 R1001
0.079
Black
K PMK2-10B
1SFA 616 504 R1006
0.079
Type
Order Code
Weight
kg
The mushroom pushbutton with
key release is delivered with two
keys.
Blocks
Contact blocks with holder
NO
NC
1 NO with holder
1 NC with holder
2 NO with holder
2 NC with holder
1 NO +1 NC with holder
K CBH-10
K CBH-01
K CBH-20
K CBH-02
K CBH-11
1SFA 616 600 R1101
1SFA 616 600 R1110
1SFA 616 600 R1102
1SFA 616 600 R1120
1SFA 616 600 R1111
0.019
0.019
0.032
0.032
0.032
1 NO without holder
1 NC without holder
K CB-10
K CB-01
SK 616 001-A
SK 616 001-B
0.013
0.013
Holder for 3 blocks
K CBH-00
SK 616 013-F
0.006
Accessories, see p. 35.
Dimension drawings, see p. 56.
ABB
13
1SFC 261001-EN, Ed. 4
Note: Both operator and
contact block(s) /lamp block
must be ordered to get
a complete pilot device
Emergency stop pushbuttons
Non-illuminated and illuminated
Operator
function
Operator
material, colour
Type
Order Code
Weight
kg
Non-illuminated operators
Ø 40 mm
Twist release
Pull release
Plastic, red
Plastic, red
K PMT3-10R
K PMP3-10R
1SFA 616 510 R1001
1SFA 616 511 R1001
0.041
0.041
Plastic, red
Plastic, red
K PMT4-10R
PMP4-10R
1SFA 616 513 R1001
1SFA 616 514 R1001
0.048
0.048
Plastic, red
Plastic, red
K PMT3-11R
K PMP3-11R
1SFA 616 510 R1101
1SFA 616 511 R1101
0.041
0.041
Plastic, red
Plastic, red
K PMT4-11R
K PMP4-11R
1SFA 616 513 R1101
1SFA 616 514 R1101
0.048
0.048
Ø 60 mm
Twist release
Pull release
Illuminated operators
Ø 40 mm
Twist release
Pull release
Ø 60 mm
Twist release
Pull release
Use adapter plate 1SFA 616 920 R 8014 (see page 29) when using
non-metallic enclosure.
● The safety holder below can only be used for the the above
mentioned type of Emergency stop pushbuttons.
●
Blocks
Type
Weight
kg
Order Code
Contact blocks and lamp block with safety holder
for emergency stop pushbuttons 1)
1 NO with safety holder
1 NC with safety holder
2 NO with safety holder
2 NC with safety holder
1 NO +1 NC with safety holder
1 NO +1 LB with safety holder 2)
1 NC +1 LB with safety holder 2)
2 NO +1 LB with safety holder 2)
2 NC +1 LB with safety hoolder 2)
1 NO +1 NC +1 LB with safety holder2)
1 NO without safety holder
K CB-10
1 NC without safety holder
K CB-01
1 LB For max 230 V AC/DC bulb, neon
bulb or LED without safety holder
K LB-1
Safety holder E-stop
K CBHS-00
NO
LB
NC
1)
14
1SFC 261001-EN, Ed. 4
K CBHS-10
K CBHS-01
K CBHS-20
K CBHS-02
K CBHS-11
K CBHS-101
K CBHS-011
K CBHS-201
K CBHS-021
K CBHS-111
No contact block in the centre
position for the illuminated
operators.
2)
1SFA 616 605 R1101
1SFA 616 605 R1110
1SFA 616 605 R1102
1SFA 616 605 R1120
1SFA 616 605 R1111
1SFA 616 605 R1201
1SFA 616 605 R1210
1SFA 616 605 R1202
1SFA 616 605 R1220
1SFA 616 605 R1211
0.021
0.021
0.032
0.032
0.032
0.033
0.033
0.044
0.044
0.044
SK 616 001-A
SK 616 001-B
0.013
0.013
SK 616 003-A
1SFA 616 605 R1100
0.015
0.010
Lamp block for max. 230 V AC/
DC. Bulb not included.
For other lamp blocks see p 35.
Accessories, see p. 35.
Dimension drawings, see p. 56.
ABB
Potentiometer
Bezel
Type
Order Code
Weight
kg
Complete potentiometer - with resistor 5 kΩ
Black knob with integrated position indication and marking in white.
Black plastic
Chrome plastic
Metal
K T-105B
K T-205B
K T-305B
1SFA 616 410 R1056
1SFA 616 410 R2056
1SFA 616 410 R3056
0.034
0.034
0.042
Complete potentiometer - with resistor 10 kΩ
Black knob with integrated position indication and marking in white.
Black plastic
Chrome plastic
Metal
Resistor data
Element type
Power rating
Mechanical angle
Terminals
Insulation voltage
Operating
temperature
Cermet
2W
280°
Solder lugs
900 V
-1°C to + 70°C
K T-110B
K T-210B
K T-310B
1SFA 616 410 R1106
1SFA 616 410 R2106
1SFA 616 410 R3106
0.034
0.034
0.042
Operating knob - without resistor
Black knob with integrated position indication and marking in white.
For shaft diameter 6 - 6.35 mm. Min. shaft length 20 mm.
Black plastic
Chrome plastic
Metal
K T-1B
K T-2B
K T-3B
1SFA 616 410 R1006
1SFA 616 410 R2006
1SFA 616 410 R3006
0.023
0.023
0.031
Suitable legend plate - see page 45.
ABB
15
1SFC 261001-EN, Ed. 4
Note: Both operator and
contact block(s) must be
ordered to get a complete
pilot device
Two-position selector switches, non-illuminated
Black plastic bezel
Weight
Symbol
Handle colour
Type
Order Code
kg
Operator with short handle 1)
Maintained
Red
Black
Grey
K 2SS1-10R
K 2SS1-10B
K 2SS1-10U
1SFA 616 200 R1001
1SFA 616 200 R1006
1SFA 616 200 R1007
0.024
0.024
0.024
Red
Black
Grey
K 2SS2-10R
K 2SS2-10B
K 2SS2-10U
1SFA 616 201 R1001
1SFA 616 201 R1006
1SFA 616 201 R1007
0.024
0.024
0.024
1SFA 616 202 R1001
1SFA 616 202 R1006
1SFA 616 202 R1007
0.024
0.024
0.024
Maintained
Momentary, spring return from C to B
Red
Black
Grey
K 2SS3-10R
K 2SS3-10B
K 2SS3-10U
Operator with long handle 1)
Maintained
Red
Black
Grey
K 2SS4-10R
K 2SS4-10B
K 2SS4-10U
1SFA 616 203 R1001
1SFA 616 203 R1006
1SFA 616 203 R1007
0.025
0.025
0.025
Red
Black
Grey
K 2SS5-10R
K 2SS5-10B
K 2SS5-10U
1SFA 616 204 R1001
1SFA 616 204 R1006
1SFA 616 204 R1007
0.025
0.025
0.025
K 2SS6-10R
K 2SS6-10B
K 2SS6-10U
1SFA 616 205 R1001
1SFA 616 205 R1006
1SFA 616 205 R1007
0.025
0.025
0.025
Type
Order Code
Weight
kg
Maintained
Bezel in chrome plastic or
metal
Replace 1 in the:
Momentary, spring return from C to B
Type K 2SSX-1 0X
Cat. No. 1SFA 616 XXX R 1 XXX
Red
Black
Grey
2 for chrome plastic bezel
3 for metal bezel
Blocks
Contact blocks and holder
NO
NC
Contact functions
Block positions as seen from
operator front.
Handle
position
Left
block
Right
block
A (B)
O
O
O
x
x
1)
1 NO with holder
K CBH-10
1SFA 616 600 R1101
0.019
1 NC with holder
K CBH-01
1SFA 616 600 R1110
0.019
2 NO with holder
K CBH-20
1SFA 616 600 R1102
0.032
2 NC with holder
K CBH-02
1SFA 616 600 R1120
0.032
1 NO +1 NC with holder
K CBH-11
1SFA 616 600 R1111
0.032
1 NO without holder
K CB-10
SK 616 001-A
0.013
1 NC without holder
K CB-01
SK 616 001-B
0.013
Holder for 3 blocks
K CBH-00
SK 616 013-F
0.006
No contact block in the centre
position.
Accessories, see p. 35.
Dimension drawings, see p. 56.
O = not influenced (normal state)
x = influenced (state changed)
16
1SFC 261001-EN, Ed. 4
ABB
Note: Both operator and
contact block(s) must be
ordered to get a complete
pilot device
Three-position selector switches, non-illuminated
Black plastic bezel
Symbol
Handle colour
Type
Order Code
Weight
kg
1SFA 616 210 R1001
1SFA 616 210 R1006
1SFA 616 210 R1007
0.024
0.024
0.024
Operator with short handle 1)
Maintained
Red
Black
Grey
K 3SS1-10R
K 3SS1-10B
K 3SS1-10U
Momentary, spring return from A to B and C to B
Red
Black
Grey
K 3SS2-10R
K 3SS2-10B
K 3SS2-10U
1SFA 616 211 R1001
1SFA 616 211 R1006
1SFA 616 211 R1007
0.024
0.024
0.024
1SFA 616 212 R1001
1SFA 616 212 R1006
1SFA 616 212 R1007
0.024
0.024
0.024
1SFA 616 216 R1001
1SFA 616 216 R1006
1SFA 616 216 R1007
0.024
0.024
0.024
1SFA 616 213 R1001
1SFA 616 213 R1006
1SFA 616 213 R1007
0.025
0.025
0.025
Momentary, spring return from C to B
Red
Black
Grey
K 3SS3-10R
K 3SS3-10B
K 3SS3-10U
Momentary, spring return from A to B
Red
Black
Grey
K 3SS7-10R
K 3SS7-10B
K 3SS7-10U
Operator with long handle 1)
Maintained
Red
Black
Grey
K 3SS4-10R
K 3SS4-10B
K 3SS4-10U
Momentary, spring return from A to B and C to B
Red
Black
Grey
K 3SS5-10R
K 3SS5-10B
K 3SS5-10U
1SFA 616 214 R1001
1SFA 616 214 R1006
1SFA 616 214 R1007
0.025
0.025
0.025
1SFA 616 215 R1001
1SFA 616 215 R1006
1SFA 616 215 R1007
0.025
0.025
0.025
1SFA 616 217 R1001
1SFA 616 217 R1006
1SFA 616 217 R1007
0.025
0.025
0.025
Momentary, spring return from C to B
Bezel in chrome plastic or
metal
Red
Black
Grey
Replace 1 in the:
K 3SS6-10R
K 3SS6-10B
K 3SS6-10U
Type K 3SSX-1 0X
Cat. No. 1SFA 616 XXX R 1 XXX
Momentary, spring return from A to B
2 for chrome plastic bezel
Red
Black
Grey
3 for metal bezel
K 3SS8-10R
K 3SS8-10B
K 3SS8-10U
Contact blocks and holder – see page 16
Contact functions
Block positions as seen from
operator front.
Handle
position
Left
block
Right
block
A
x
O
B
O
O
C
O
x
1)
No contact block in the centre
position.
Accessories, see p. 35.
Dimension drawings, see p. 56.
O = not influenced (normal state)
x = influenced (state changed)
ABB
17
1SFC 261001-EN, Ed. 4
Note: Both operator and
contact block(s) /lamp block
must be ordered to get
a complete pilot device
Two-position selector switches, illuminated
Black plastic bezel
Weight
Symbol
Handle colour
Type
Order Code
kg
Operator with short handle 1)
Maintained
Red
Gren
Yellow
Blue
Clear
K 2SS1-11R
K 2SS1-11G
K 2SS1-11Y
K 2SS1-11L
K 2SS1-11C
1SFA 616 200 R1101
1SFA 616 200 R1102
1SFA 616 200 R1103
1SFA 616 200 R1104
1SFA 616 200 R1108
0.024
0.024
0.024
0.024
0.024
Red
Gren
Yellow
Blue
Clear
K 2SS2-11R
K 2SS2-11G
K 2SS2-11Y
K 2SS2-11L
K 2SS2-11C
1SFA 616 201 R1101
1SFA 616 201 R1102
1SFA 616 201 R1103
1SFA 616 201 R1104
1SFA 616 201 R1108
0.024
0.024
0.024
0.024
0.024
1SFA 616 202 R1101
1SFA 616 202 R1102
1SFA 616 202 R1103
1SFA 616 202 R1104
1SFA 616 202 R1108
0.024
0.024
0.024
0.024
0.024
Maintained
Momentary, spring return from C to B
Red
Gren
Yellow
Blue
Clear
K 2SS3-11R
K 2SS3-11G
K 2SS3-11Y
K 2SS3-11L
K 2SS3-11C
Operator with long handle 1)
Maintained
Red
Gren
Yellow
Blue
Clear
K 2SS4-11R
K 2SS4-11G
K 2SS4-11Y
K 2SS4-11L
K 2SS4-11C
1SFA 616 203 R1101
1SFA 616 203 R1102
1SFA 616 203 R1103
1SFA 616 203 R1104
1SFA 616 203 R1108
0.025
0.025
0.025
0.025
0.025
Red
Gren
Yellow
Blue
Clear
K 2SS5-11R
K 2SS5-11G
K 2SS5-11Y
K 2SS5-11L
K 2SS5-11C
1SFA 616 204 R1101
1SFA 616 204 R1102
1SFA 616 204 R1103
1SFA 616 204 R1104
1SFA 616 204 R1108
0.025
0.025
0.025
0.025
0.025
K 2SS6-11R
K 2SS6-11G
K 2SS6-11Y
K 2SS6-11L
K 2SS6-11C
1SFA 616 205 R1101
1SFA 616 205 R1102
1SFA 616 205 R1103
1SFA 616 205 R1104
1SFA 616 205 R1108
0.025
0.025
0.025
0.025
0.025
Type
Order Code
Maintained
Bezel in chrome plastic or
metal
Replace 1 in the:
Type K 2SSX-1 1X
Cat. No. 1SFA 616 XXX R 1 1XX
Momentary, spring return from C to B
2 for chrome plastic bezel
Red
Gren
Yellow
Blue
Clear
3 for metal bezel
Blocks
Weight, kg
Contact blocks, lamp block and holder
1 NO + 1 LB with holder 2)
K CBH-101
1SFA 616 600 R1201
0.034
1 NC + 1 LB with holder 2)
K CBH-011
1SFA 616 600 R1210
0.034
2 NO + 1 LB with holder 2)
K CBH-201
1SFA 616 600 R1202
0.047
2 NC + 1LB with holder
K CBH-021
1SFA 616 600 R1220
0.047
K CBH-111
K CB-10
K CB-01
1SFA 616 600 R1211
SK 616 001-A
SK 616 001-B
0.047
0.013
0.013
K LB-1
K CBH-00
SK 616 003-A
SK 616 013-F
0.013
0.006
2)
1 NO +1 NC + 1 LB with holder 2)
1 NO without holder
1 NC without holder
Lamp block for 2 W, max230 V AC
and DC bulb, neon bulb or LED
Holder for 3 blocks
NO
LB
NC
Contact functions
Block positions as seen from
operator front.
Handle
position
Left
block
Right
block
A (B)
O
O
O
x
x
1)
No contact block in the centre
position.
2)
Lamp block for max. 230 V AC/
DC.
Bulb not included.
For other lamp blocks see p. 35
Accessories, see p. 35.
Dimension drawings, see p. 56.
O = not influenced (normal state)
x = influenced (state changed)
18
1SFC 261001-EN, Ed. 4
ABB
Note: Both operator and
contact block(s) /lamp block
must be ordered to get
a complete pilot device
Three-position selector switches, illuminated
Black plastic bezel
Symbol
Handle colour
Type
Weight
kg
Order Code
Operator with short handle 1)
Maintained
Red
Gren
Yellow
Blue
Clear
K 3SS1-11R
K 3SS1-11G
K 3SS1-11Y
K 3SS1-11L
K 3SS1-11C
1SFA 616 210 R1101
1SFA 616 210 R1102
1SFA 616 210 R1103
1SFA 616 210 R1104
1SFA 616 210 R1108
0.024
0.024
0.024
0.024
0.024
Momentary, spring return from A to B and C to B
Red
Gren
Yellow
Blue
Clear
K 3SS2-11R
K 3SS2-11G
K 3SS2-11Y
K 3SS2-11L
K 3SS2-11C
1SFA 616 211 R1101
1SFA 616 211 R1102
1SFA 616 211 R1103
1SFA 616 211 R1104
1SFA 616 211 R1108
0.024
0.024
0.024
0.024
0.024
1SFA 616 212 R1101
1SFA 616 212 R1102
1SFA 616 212 R1103
1SFA 616 212 R1104
1SFA 616 212 R1108
0.024
0.024
0.024
0.024
0.024
1SFA 616 216 R1101
1SFA 616 216 R1102
1SFA 616 216 R1103
1SFA 616 216 R1104
1SFA 616 216 R1108
0.024
0.024
0.024
0.024
0.024
1SFA 616 213 R1101
1SFA 616 213 R1102
1SFA 616 213 R1103
1SFA 616 213 R1104
1SFA 616 213 R1108
0.025
0.025
0.025
0.025
0.025
Momentary, spring return from C to B
Red
Gren
Yellow
Blue
Clear
K 3SS3-11R
K 3SS3-11G
K 3SS3-11Y
K 3SS3-11L
K 3SS3-11C
Momentary, spring return from A to B
Red
Gren
Yellow
Blue
Clear
K 3SS7-11R
K 3SS7-11G
K 3SS7-11Y
K 3SS7-11L
K 3SS7-11C
Operator with long handle 1)
Maintained
Red
Gren
Yellow
Blue
Clear
K 3SS4-11R
K 3SS4-11G
K 3SS4-11Y
K 3SS4-11L
K 3SS4-11C
Momentary, spring return from A to B and C to B
Red
Gren
Yellow
Blue
Clear
K 3SS5-11R
K 3SS5-11G
K 3SS5-11Y
K 3SS5-11L
K 3SS5-11C
1SFA 616 214 R1101
1SFA 616 214 R1102
1SFA 616 214 R1103
1SFA 616 214 R1104
1SFA 616 214 R1108
0.025
0.025
0.025
0.025
0.025
1SFA 616 215 R1101
1SFA 616 215 R1102
1SFA 616 215 R1103
1SFA 616 215 R1104
1SFA 616 215 R1108
0.025
0.025
0.025
0.025
0.025
1SFA 616 217 R1101
1SFA 616 217 R1102
1SFA 616 217 R1103
1SFA 616 217 R1104
1SFA 616 217 R1108
0.025
0.025
0.025
0.025
0.025
Momentary, spring return from C to B
Bezel in chrome plastic or
metal
Red
Gren
Yellow
Blue
Clear
Replace 1 in the:
Type K 3SSX-1 1X
Cat. No. 1SFA 616 XXX R 1 1XX
K 3SS6-11R
K 3SS6-11G
K 3SS6-11Y
K 3SS6-11L
K 3SS6-11C
2 for chrome plastic bezel
Momentary, spring return from A to B
3 for metal bezel
Red
Gren
Yellow
Blue
Clear
K 3SS8-11R
K 3SS8-11G
K 3SS8-11Y
K 3SS8-11L
K 3SS8-11C
Contact blocks, lamp block and holder – see page 18
Contact functions
Block positions as seen from
operator front.
Handle
position
Left
block
Right
block
A
x
O
B
O
O
C
O
x
1)
No contact block in the centre
position.
2)
Lamp block for max. 230 V AC/
DC.
Bulb not included.
For other lamp blocks see p. 35
Accessories, see p. 35.
Dimension drawings, see p. 56.
O = not influenced (normal state)
x = influenced (state changed)
ABB
19
1SFC 261001-EN, Ed. 4
Note: Both operator and
contact block(s) must be
ordered to get a complete
pilot device
Key-operated selector switches
Symbol
The key can be
removed
Type
Order Code
Weight
kg
Operator – two positions 3)
Maintained
In both positions
K 2SSK1-10■ 1)
1SFA 616 280 R100 ■ 1)
0.069
In position B only
K 2SSK2-10■ 1)
1SFA 616 281 R100 ■ 1)
0.069
1SFA 616 282 R100 ■ 1)
0.069
Maintained
The key-operated selector
switches are delivered with two
keys.
Momentary, spring return from C to B
In position B only
K 2SSK3-10■ 1)
Operator – three positions 3)
Maintained
In all positions
K 3SSK1-10■ 1)
1SFA 616 283 R100 ■ 1)
0.069
In position B only
K 3SSK2-10■ 1)
1SFA 616 284 R100 ■ 1)
0.069
Maintained
1
) Key code codes
Momentary, spring return from A to B and C to B
Key code
Code
71 (standard)
72
73
Other
■=1
■=2
■=3
In position B only
K 3SSK3-10■ 1)
1SFA 616 285 R100 ■ 1)
0.069
1SFA 616 286 R100 ■ 2)
0.069
1SFA 616 287 R100 ■ 1)
0.069
Momentary, spring return from C to B
On request
In position A only
K 3SSK4-10■ 1)
2
) Key code codes
Key code
Code
71 (standard)
72
■=1
■=2
Momentary, spring return from C to B
In all positions
*)
K 3SSK5-10■ 1)
To improve antirotation use guide washer 2154 373-2. See page 38.
Blocks
Type
Order Code
Weight
kg
Contact blocks and holder
2 NO with holder
K CBH-20
1SFA 616 600 R1102
0.032
2 NC with holder
K CBH-02
1SFA 616 600 R1120
0.032
1 NO +1 NC with holder
K CBH-11
1SFA 616 600 R1111
0.032
1 NO without holder
K CB-10
SK 616 001-A
0.013
1 NC without holder
K CB-01
SK 616 001-B
0.013
Holder for 3 blocks
K CBH-00
SK 616 013-F
0.006
NO
NC
Contact functions
Two positions: see page 18
3)
No contact block in the centre
position.
Accessories, see p. 35.
Dimension drawings, see p. 56.
Three positions: see page 19
20
1SFC 261001-EN, Ed. 4
ABB
Note: Both operator and
contact block(s) must be
ordered to get a complete
pilot device
Toggle switches
Symbol
Bezel
Type
Order Code
Weight
kg
K TS1-10B
K TS1-20B
K TS1-30B
1SFA 616 300 R1006
1SFA 616 300 R2006
1SFA 616 300 R3006
0.021
0.021
0.021
Operator – two positions
Maintained 1)
Black plastic
Chrome plastic
Metal
Operator – three positions
Momentary, spring return from A to B and C to B 1)
Black plastic
Chrome plastic
Metal
K TS2-10B
K TS2-20B
K TS2-30B
1SFA 616 301 R1006
1SFA 616 301 R2006
1SFA 616 301 R3006
0.021
0.021
0.021
K TS3-10B
K TS3-20B
K TS3-30B
1SFA 616 302 R1006
1SFA 616 302 R2006
1SFA 616 302 R3006
0.021
0.021
0.021
Type
Cat.No.
Weight
kg
Maintained 2)
Black plastic
Chrome plastic
Metal
Blocks
Contact blocks and holder
NO
NC
1 NO with holder
K CBH-10
1SFA 616 600 R1101
0.019
1 NC with holder
K CBH-01
1SFA 616 600 R1110
0.019
2 NO with holder
K CBH-20
1SFA 616 600 R1102
0.032
2 NC with holder
K CBH-02
1SFA 616 600 R1120
0.032
1 NO +1 NC with holder
K CBH-11
1SFA 616 600 R1111
0.032
1 NO without holder
K CB-10
SK 616 001-A
0.013
1 NC without holder
K CB-01
SK 616 001-B
0.013
Holder for 3 blocks
K CBH-00
SK 616 013-F
0.006
Contact functions
Block positions as seen from
operator front.
Right
block
Three-position momentary switch
Handle
Left
Right
position
block
block
Three-position maintained switch
Handle
Left
Middle Right
position block
block
block
O
O
A
x
O
A
O
x
x
x
x
B
O
O
B
O
O
O
C
O
x
C
x
x
O
Two-position switch
Handle
Left
position
block
A
C
O = not influenced (normal state)
x = influenced (state changed)
ABB
O = not influenced (normal state)
x = influenced (state changed)
1)
No contact block in centre
position.
2)
Contact block in centre position
is influenced in both position A
and C.
Accessories, see p. 35.
Dimension drawings, see p. 56.
O = not influenced (normal state)
x = influenced (state changed)
21
1SFC 261001-EN, Ed. 4
Note: Both pilot light head
and lamp block must be
ordered to get a complete
pilot light
Pilot lights and buzzers
Lens
colour
Weight,
kg
Type
Order Code
Red
Green
Yellow
Blue
White
Clear
K L1-100R
K L1-100G
K L1-100Y
K L1-100L
K L1-100W
K L1-100C
1SFA 616 400 R1001
1SFA 616 400 R1002
1SFA 616 400 R1003
1SFA 616 400 R1004
1SFA 616 400 R1005
1SFA 616 400 R1008
Supply voltage
Type
Order Code
Pilot light heads 1)
0.018
0.018
0.018
0.018
0.018
0.018
Weight,
kg
Lamp blocks with holder
max. 230 V AC /DC
1)
K CBH-001
1SFA 616 600 R1200
0.021
115 V AC
1)
K CBH-002
1SFA 616 600 R1300
0.023
230 V AC
1)
K CBH-003
1SFA 616 600 R1400
0.026
Type
Order Code
Lens
colour
Weight,
kg
Compact Pilot lights 1)
Direct supply. max 240 V, 3 W.
Use filament bulb for best light.
With LED or neon bulb add light diffusing lens.
Red
Green
Yellow
Blue
White
Clear
K L2-100R
K L2-100G
K L2-100Y
K L2-100L
K L2-100W
K L2-100C
Type
1SFA 616 402 R1001
1SFA 616 402 R1002
1SFA 616 402 R1003
1SFA 616 402 R1004
1SFA 616 402 R1005
1SFA 616 402 R1008
0.017
0.017
0.017
0.017
0.017
0.017
Weight,
kg
Order Code
Light diffusing lens – Accessory for pilot light
The lens is used instead of text cap
Supply voltage
Tone type
1SFA 616 920 R8005
Type
0.001
Weight,
kg
Order Code
Buzzers
Black. Frequency: Approx. 2400 Hz. Loudness: Min 80 dB(A)/10 cm,
Rated current:≤8 mA. Service life >5000 h
24 V AC/DC
Continuous
K B1-4010
1SFA 616 401 R4010
115 V AC/DC
Continuous
K B1-4030
1SFA 616 401 R4030
230 V AC
Continuous
K B1-4040
1SFA 616 401 R4040
24 V AC/DC
Pulsating
K B1-4110
1SFA 616 401 R4110
115 V AC/DC
Pulsating
K B1-4130
1SFA 616 401 R4130
230 V AC
Pulsating
K B1-4140
1SFA 616 401 R4140
1)
22
1SFC 261001-EN, Ed. 4
Bulb not included.
0.020
0.020
0.020
0.020
0.020
0.020
Accessories, see p. 29
Dimension drawings, see p. 56-57
ABB
Signal Towers K 70 and Signal Beacons K SB
Signal Towers K 70
- Fast mounting of signal
elements using bayonet
fixing
- Easy changing of bulbs for
each module without tools
Simple fitting with quick fix system
Each K 70 module is equipped with a bayonet fixing with integral
contact system. The modules are fastened together by aligning the
corresponding white marks then with a gentle twist they are locked
into place (see the figures).
- Flexibility of signal element
combination
- Up to 5 elements possible/up
to 10 elements with bracket
for 2-sided mounting
- Flashing light elements can
be mounted in each module
- Up to 5 flashing light
elements possible
- High protection rating
optical and audible signal
elements with IP 54.
- LED elements for long life
Connection plan
Connection plan with AS
Interface module
Uextern (-)
Uextern (+)
4
3
2
1
ASI (+)
5
0
ASI (-)
Signal Beacons K SB
- Vandal-proof design withstands
every mechanical and natural challenge
both indoors and outdoors.
- High protection rating IP 65
- Cap consists of high impact polycarbonate (up to 20 J).
- Bulb change via inside of control box.
ABB
23
1SFC 261001-EN, Ed. 4
Signal Towers K 70
Colour
Type
Order Code
Weight,
kg
Optical modules
Light element
Permanent light, 12-240 V AC/DC. For bulb BA15d. Bulb not included.
Red
Green
Yellow
Blue
Clear
K L70-401R
K L70-401G
K L70-401Y
K L70-401L
K L70-401C
1SFA 616 070 R4011
1SFA 616 070 R4012
1SFA 616 070 R4013
1SFA 616 070 R4014
1SFA 616 070 R4018
0.09
0.09
0.09
0.09
0.09
Blinking light, 24 V AC/DC. For bulb BA15d. Bulb not included.
Red
Green
Yellow
Blue
Clear
K L70-302R
K L70-302G
K L70-302Y
K L70-302L
K L70-302C
1SFA 616 070 R3021
1SFA 616 070 R3022
1SFA 616 070 R3023
1SFA 616 070 R3024
1SFA 616 070 R3028
0.10
0.10
0.10
0.10
0.10
Flashing light, 24 V DC. Xenon tube included. Not changeable.
Red
Green
Yellow
Blue
Clear
K L70-203R
K L70-203G
K L70-203Y
K L70-203L
K L70-203C
1SFA 616 070 R2031
1SFA 616 070 R2032
1SFA 616 070 R2033
1SFA 616 070 R2034
1SFA 616 070 R2038
0.12
0.12
0.12
0.12
0.12
Blinking light, 115 V AC/DC. For bulb BA15d. Bulb not included.
Red
Green
Yellow
Blue
Clear
K L70-312R
K L70-312G
K L70-312Y
K L70-312L
K L70-312C
1SFA 616 070 R3121
1SFA 616 070 R3122
1SFA 616 070 R3123
1SFA 616 070 R3124
1SFA 616 070 R3128
0.10
0.10
0.10
0.10
0.10
Flashing light, 115 V AC. Xenon tube included. Not changeable.
Red
Green
Yellow
Blue
Clear
K L70-113R
K L70-113G
K L70-113Y
K L70-113L
K L70-113C
1SFA 616 070 R1131
1SFA 616 070 R1132
1SFA 616 070 R1133
1SFA 616 070 R1134
1SFA 616 070 R1138
0.11
0.11
0.11
0.11
0.11
Blinking light, 230 V AC/DC. For bulb BA15d. Bulb not included.
Red
Green
Yellow
Blue
Clear
K L70-322R
K L70-322G
K L70-322Y
K L70-322L
K L70-322C
1SFA 616 070 R3221
1SFA 616 070 R3222
1SFA 616 070 R3223
1SFA 616 070 R3224
1SFA 616 070 R3228
0.10
0.10
0.10
0.10
0.10
Flashing light, 230 V AC. Xenon tube included. Not changeable.
Red
Green
Yellow
Blue
Clear
K L70-123R
K L70-123G
K L70-123Y
K L70-123L
K L70-123C
1SFA 616 070 R1231
1SFA 616 070 R1232
1SFA 616 070 R1233
1SFA 616 070 R1234
1SFA 616 070 R1238
0.11
0.11
0.11
0.11
0.11
LED Permanent light, 24 V AC/DC. LED included. Not changeable.
Red
Green
Yellow
K L70-305R
K L70-305G
K L70-305Y
1SFA 616 070 R3051
1SFA 616 070 R3052
1SFA 616 070 R3053
0.10
0.10
0.10
LED Blinking light, 24 V AC/DC. LED included. Not changeable.
Red
Green
Yellow
K L70-306R
K L70-306G
K L70-306Y
1SFA 616 070 R3061
1SFA 616 070 R3062
1SFA 616 070 R3063
0.10
0.10
0.10
LED Rotating light, 24 V AC/DC. LED included. Not changeable.
Red
Green
Yellow
K L70-307R
K L70-307G
K L70-307Y
1SFA 616 070 R3071
1SFA 616 070 R3072
1SFA 616 070 R3073
0.10
0.10
0.10
Bulbs for Signal Tower K 70 Max 7 W For permanent or blinking light.
Bulb BA15d, 42 mm, :
24 V, 5 W
115 V, 5 W
230 V, 5 W
1SFA 616 923 R1028
1SFA 616 923 R1118
1SFA 616 923 R1148
0.009
0.009
0.009
Dimension drawings, see p. 58.
24
1SFC 261001-EN, Ed. 4
ABB
Signal Towers K 70
Accessories
Description
Type
Order Code
Weight,
kg
Audible modules
Buzzer element
85 dB, continuous or pulsating tone, adjustable
230 V AC
K B70-1201
1SFA 616 071 R1201
24 V AC/DC
K B70-3001
1SFA 616 071 R3001
115 V AC/DC
K B70-3101
1SFA 616 071 R3101
0.12
0.11
0.11
Siren element
Multi function, 8 diff. tones adjustable, volume adjustable
100 dB, 115 V AC
K S70-1104
1SFA 616 073 R1104
0.13
Multi function, 8 diff. tones adjustable, volume adjustable
100 dB, 230 V AC
K S70-1204
1SFA 616 073 R1204
0.12
Multi function, 7 diff. tones adjustable, volume adjustable, remote control
100 dB, 24 V DC
K S70-2004
1SFA 616 073 R2004
0.12
Multi function, 8 diff. tones adjustable, volume adjustable
100 dB, 24 V AC/DC K S70-3004
1SFA 616 073 R3004
0.12
Continuous tone alternating
108 dB, 24 V DC
K S70-2002
1SFA 616 073 R2002
0.15
AS-Interface Module
{
K ASI-4101
1SFA 616 079 R4101
0.11
for external voltage
18,5-31,6 V AC/DC
K ASI-4102
1SFA 616 079 R4102
0.14
Terminal elements
(K T70)
max 5
elements
18,5-31,6 V AC/DC
K B70/K S70
For tube mounting,
including cap
K T70-1001
1SFA 616 075 R1001
0.15
For bracket or base,
including cap
K T70-1002
1SFA 616 075 R1002
0.15
Cable exit at side
K A70-1001
1SFA 616 077 R1001
0.07
Magnetic base
K A70-1002
1SFA 616 077 R1002
0.31
D=25 mm L=110 mm K A70-1011
1SFA 616 077 R1011
0.06
K ASI
K L70
K T70-1002
K T70-1001
Special parts
Contact box
K A70-1021
K A70-1031
K A70-1001
K A70-1032
K A70-1022
K A70-1001
Base with tube
Base for tube
D=25 mm, Plastic
K A70-1012
1SFA 616 077 R1012
0.03
D=25 mm, Metal
K A70-1013
1SFA 616 077 R1013
0.32
K A70-1011
K A70-1013
Tube, anodized aluminium
KA 70-1012
D=25 mm L=250 mm K A70-1021
1SFA 616 077 R1021
0.08
D=25 mm L=400 mm K A70-1022
1SFA 616 077 R1022
0.12
K A70-1001
Bracket
K A70-1002
1-sided mounting
K A70-1031
1SFA 616 077 R1031
0.08
2-sided mounting
K A70-1032
1SFA 616 077 R1032
0.07
Dimension drawings, see p. 58.
ABB
25
1SFC 261001-EN, Ed. 4
Signal Beacons K SB
Colour
Type
Order Code
Weight,
kg
Signal Beacons
Permanent light, 12-240 V AC/DC. For bulb BA15d. Bulb not included.
Red
K SB-401R
1SFA 616 080 R4011
Green
K SB-401G
1SFA 616 080 R4012
Yellow
K SB-401Y
1SFA 616 080 R4013
Blue
K SB-401L
1SFA 616 080 R4014
Clear
K SB-401C
1SFA 616 080 R4018
0.13
0.13
0.13
0.13
0.13
Flashing light, 24 V DC. Xenon tube included. Not changeable.
Red
K SB-203R
1SFA 616 080 R2031
Green
K SB-203G
1SFA 616 080 R2032
Yellow
K SB-203Y
1SFA 616 080 R2033
Blue
K SB-203L
1SFA 616 080 R2034
Clear
K SB-203C
1SFA 616 080 R2038
0.14
0.14
0.14
0.14
0.14
Flashing light, 115 V AC. Xenon tube included. Not changeable.
Red
K SB-113R
1SFA 616 080 R1131
Green
K SB-113G
1SFA 616 080 R1132
Yellow
K SB-113Y
1SFA 616 080 R1133
Blue
K SB-113L
1SFA 616 080 R1134
Clear
K SB-113C
1SFA 616 080 R1138
0.14
0.14
0.14
0.14
0.14
Flashing light, 230 V AC. Xenon tube included. Not changeable.
Red
K SB-123R
1SFA 616 080 R1231
Green
K SB-123G
1SFA 616 080 R1232
Yellow
K SB-123Y
1SFA 616 080 R1233
Blue
K SB-123L
1SFA 616 080 R1234
Clear
K SB-123C
1SFA 616 080 R1238
0.14
0.14
0.14
0.14
0.14
LED Permanent light, 24 V AC/DC. LED included. Not changeable.
Red
K SB-305R
1SFA 616 080 R3051
Green
K SB-305G
1SFA 616 080 R3052
Yellow
K SB-305Y
1SFA 616 080 R3053
0.14
0.14
0.14
LED Blinking light, 24 V AC/DC. LED included. Not changeable.
Red
K SB-306R
1SFA 616 080 R3061
Green
K SB-306G
1SFA 616 080 R3062
Yellow
K SB-306Y
1SFA 616 080 R3063
0.14
0.14
0.14
LED Rotating light, 24 V AC/DC. LED included. Not changeable.
Red
K SB-307R
1SFA 616 080 R3071
Green
K SB-307G
1SFA 616 080 R3072
Yellow
K SB-307Y
1SFA 616 080 R3073
0.14
0.14
0.14
Special parts
Anti-twist device
K ASB-1000
1SFA 616 087 R1000
Bulbs for Signal Beacons Max 10 W. For permanent light.
Bulb BA15d, 52 mm:
12 V, 7 W
24 V, 7 W
115 V, 7 W
220-260 V, 7-10 W
1SFA 616 922 R1018
1SFA 616 922 R1028
1SFA 616 922 R1118
1SFA 616 922 R1148
0.011
0.011
0.011
0.011
Dimension drawings, see p. 59
26
1SFC 261001-EN, Ed. 4
ABB
Reset buttons
Lens
Colour
Weight,
kg
Order Code
Without shaft
With flush button
Red
Green
Yellow
Blue
White
White with black "R"
Black
Clear
SK 616 204-AA
SK 616 204-AB
SK 616 204-AC
SK 616 204-AD
SK 616 204-AE
SK 616 404-A
SK 616 204-AF
SK 616 204-AH
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
SK 616 204-DA
SK 616 204-DB
SK 616 204-DC
SK 616 204-DD
SK 616 204-DE
SK 616 204-DF
SK 616 204-DH
0.021
0.021
0.021
0.021
0.021
0.021
0.021
SK 616 404-B
SK 616 404-C
SK 616 404-D
0.027
0.027
0.027
5396 0562-1
0.007
With extended button
Red
Green
Yellow
Blue
White
Black
Clear
With shaft 2)
With flush button
White with black "R"
Black with white "RESET"
Blue with black "R"
Shaft
30 – 200 mm 2)
Dimensions
ABB
1)
Length of stroke.
2)
Can be cut to desired length.
27
1SFC 261001-EN, Ed. 4
Enclosures, non-metallic
Degree of protection IP 65
Size
Colour
top/bottom
Order Code
1-seat
Grey/black
SK 616 801-AA
0.16
1-seat
Yellow/black
SK 616 801-DA
0.16
2-seat
Grey/black
SK 616 802-AA
0.21
3-seat
Grey/black
SK 616 803-AA
0.25
4-seat
Grey/black
SK 616 804-AA
0.31
6-seat
Grey/black
SK 616 806-AA
0.40
When ordering
Use the order form on page 51.
Weight,
kg
Dimension drawings, see p. 60.
• Select operators from page 6-22.
• Select contact blocks and lamp blocks for
▼
N.B. Operators for vertically mounted selector
switches must be ordered from page 30-31.
3 pos. toggle switches and double pushbuttons
are not available for vertical mounting.
rear mounting, see page 29.
• Accessories, see page 29 and 37.
N.B. One spacer per operator has to be ordered if legend
plate is not used.
28
1SFC 261001-EN, Ed. 4
ABB
Enclosures, non-metallic
Accessories
Description
Type
Weight,
kg
Order Code
Contact block for rear mounting
1NO
1NC
K CB-10B
K CB-01B
SK 616 002-A
SK 616 002-B
0.013
0.013
Contact block with gold plated contacts for rear mounting
1NO
1NC
K CB-10BG
K CB-01BG
SK 616 008-A
SK 616 008-B
0.013
0.013
Lamp block for rear mounting
For 2 W, max. 230 V AC and DC bulb,
neon lamp or LED.
K LB-1B
SK 616 003-D
0.015
115 V AC supply voltage.
60 V lamp max. 1.2 W. K LB-2B
SK 616 003-E
0.017
230 V AC supply voltage.
130 V lamp max. 2 W. K LB-3B
SK 616 003-F
0.020
Protective sleeve
To make a rear mounted lamp block screen protected, IP 20.
Protective sleeve
5396 0543-1
0.002
Cable gland
Black plastic. Threaded outer sleeve. Sealing ring Pr 22.5 included.
Pr
Pg
22.5 16
28.3 21
Sleeve diameter
min. mm
Sealing
diameter mm
18
24
9 – 15
12 - 20
SK 175 931-AF
SK 175 931-AK
0.010
0.017
SK 175 923-3
SK 175 923-4
0.002
0.004
Nut
Black plastic. For cable gland above.
Pr
Pg
22.5 16
28.3 21
Earthing terminal
For non-metallic enclosure. 1-seat enclosure has space for one terminal
and the others have space for two terminals.
Earthing device
SK 615 017-A
0.005
Spacer
1mm thick. Needed when legend plates are not used in non-metallic enclosures.
Spacer
Spacer for Emergency Stop
Pushbutton on page 14
SK 615 516-1
0.002
1SFA 616 920 R8045
0.004
SK 616 502-B
0.030
Blanking plug
Black non-metallic
Impact protection
For increased protection against heavy shocks.
Impact protection
SK 616 590-D
0.010
Adapter plate
For Emergency Stop pushbuttons on page 14. For rear mounted
contact blocks and lamp blocks.
1SFA 616 920 R8014
ABB
0.007
29
1SFC 261001-EN, Ed. 4
Selector switches, two positions
Only for vertically mounted enclosures
Handle
colour
Symbol
Type
Weight,
kg
Order Code
Short handle – non-illuminated
Maintained
Red
Black
K 2SSV1-10R 1SFA 616 220 R1001
K 2SSV1-10B 1SFA 616 220 R1006
0.024
0.024
Red
Black
K 2SSV2-10R 1SFA 616 221 R1001
K 2SSV2-10B 1SFA 616 221 R1006
0.024
0.024
Momentary, spring return from C to B
Red
Black
K 2SSV3-10R 1SFA 616 222 R1001
K 2SSV3-10B 1SFA 616 222 R1006
0.024
0.024
Short handle – illuminated
Maintained
Bezel in chrome plastic or metal
Replace 1 in the
Type K 2SSVX-1 XX
Cat. No. 1SFA 616 XXX R 1 XXX
Red
Green
Yellow
K 2SSV1-11R 1SFA 616 220 R1101
K 2SSV1-11G 1SFA 616 220 R1102
K 2SSV1-11Y 1SFA 616 220 R1103
0.024
0.024
0.024
Red
Green
Yellow
K 2SSV2-11R 1SFA 616 221 R1101
K 2SSV2-11G 1SFA 616 221 R1102
K 2SSV2-11Y 1SFA 616 221 R1103
0.024
0.024
0.024
Momentary, spring return from C to B
Red
Green
Yellow
2 for chrome plastic bezel
K 2SSV3-11R 1SFA 616 222 R1101
K 2SSV3-11G 1SFA 616 222 R1102
K 2SSV3-11Y 1SFA 616 222 R1103
0.024
0.024
0.024
3 for metal bezel
Contact blocks and lamp blocks – see page 29
Contact functions
Block positions as seen from
operator front.
Accessories, see p. 29 and 37.
Dimension drawings, see p. 56.
No contact block in the centre
position.
Handle
position
Lower
block
Upper
block
A (B)
O
O
C
x
x
O = not influenced (normal state)
x = influenced (state changed)
30
1SFC 261001-EN, Ed. 4
ABB
Selector switches, three positions
Only for vertically mounted enclosures
Handle
colour
Symbol
Type
Weight,
kg
Order Code
Short handle – non-illuminated
Maintained
Red
Black
K 3SSV1-10R
K 3SSV1-10B
1SFA 616 230 R1001
1SFA 616 230 R1006
0.024
0.024
Momentary, spring return from A and C to B
Red
Black
K 3SSV2-10R
K 3SSV2-10B
1SFA 616 231 R1001
1SFA 616 231 R1006
0.024
0.024
1SFA 616 232 R1001
1SFA 616 232 R1006
0.024
0.024
1SFA 616 230 R1101
1SFA 616 230 R1102
1SFA 616 230 R1103
0.024
0.024
0.024
Momentary, spring return from C to B
Red
Black
K 3SSV3-10R
K 3SSV3-10B
Short handle – illuminated
Maintained
Red
Green
Yellow
K 3SSV1-11R
K 3SSV1-11G
K 3SSV1-11Y
Momentary, spring return from A and C to B
Red
Green
Yellow
Bezel in chrome plastic or metal
Replace 1 in the
Type K 2SSVX-1 XX
Cat. No. 1SFA 616 XXX R 1 XXX
K 3SSV2-11R
K 3SSV2-11G
K 3SSV2-11Y
1SFA 616 231 R1101
1SFA 616 231 R1102
1SFA 616 231 R1103
0.024
0.024
0.024
1SFA 616 232 R1101
1SFA 616 232 R1102
1SFA 616 232 R1103
0.024
0.024
0.024
Momentary, spring return from C to B
Red
Green
Yellow
2 for chrome plastic bezel
3 for metal bezel
K 3SSV3-11R
K 3SSV3-11G
K 3SSV3-11Y
Contact blocks and lamp blocks – see page 29
Contact functions
Block positions as seen from
operator front.
Accessories, see p. 29 and 37.
Dimension drawings, see p. 56.
No contact block in the centre
position.
Handle
position
Lower
block
Upper
block
A
x
O
B
O
O
C
O
x
O = not influenced (normal state)
x = influenced (state changed)
ABB
31
1SFC 261001-EN, Ed. 4
Enclosures, metallic
Degree of protection IP 671)
Weight,
kg
Size
Colour
Order Code
1-seat
Grey
SK 616 701-AA
0.40
2-seat
Grey
SK 616 702-AA
0.70
3-seat
Grey
SK 616 703-AA
0.80
4-seat
Grey
SK 616 704-AA2)
1.20
6-seat
Grey
SK 616 706-AA2)
1.40
Select contact blocks for front mounting, see page 35.
Select lamp blocks for front mounting, see page 35.
Select accessories from page 33, 36-38.
1) Pushbuttons with sealing
membrane
32
1SFC 261001-EN, Ed. 4
2) Flanges are not included
Dimension drawings, see p. 60.
ABB
Enclosures, metallic
Accessories
Description
Order Code
Weight,
kg
Cable gland
Metal. Threaded outer sleeve. Sealing ring Pr 22.5 (Pg 16) included.
Pr
Pg
Sealing
diameter mm
22.5
22.5
22.5
16
16
16
8.5 – 11.5
10.5 – 13.5
12.5 – 15.0
SK 170 7685
SK 170 7686
SK 170 7687
0.040
0.045
0.050
SK 175 0152
0.010
Hexagon nut
Metal.
Pr 22.5 Pg 16
Blanking plates
Without holes. Metal. Black. For 4- and 6-seat enclosures. Note: Gasket not included
For flange
opening
Suitable flange gasket
Order Code
FL 13
SK 170 4536
SK 172 105-AA
0.110
With holes. Metal. Black. For 4- and 6-seat enclosures. Note: Gasket not included
For flange
opening
Suitable flange gasket
Order Code
Two threaded holes Pr 22.5 (Pg 16). Hole centre distance 50 mm.
FL 13
SK 170 4536
SK 172 105-AD
0.110
Three threaded holes Pr 22.5 (Pg 16). Hole centre distance 38 mm.
FL 13
SK 170 4536
SK 172 105-AE
0.100
Four threaded holes Pr 22.5 (Pg 16). Hole centre distance 30 mm.
FL 13
SK 170 4536
SK 172 105-AF
0.100
Flange gasket
FL 13
SK 170 4536
0.005
Blanking plug
Applicable to cover a 22 mm-hole in an
enclosure instead of an operator.
Gasket and nut included.
Black non-metallic
SK 616 502-B
0.030
Sealing plug
Plastic. Black.
For holes
Pr 22.5 Pg 16
ABB
SK 175 919-3
0.010
33
1SFC 261001-EN, Ed. 4
Assembled stations
Fig.
See
below 1)
Legend
plate text
Left
Centre
Button/
cap col,our
Left
Centre
Right
Right
Weight
kg
Order Code
Non-metallic enclosures
Degree of protection IP 65, (dependent on the degree of protection of each pushbutton)
1-seat, grey top/black bottom
One pushbutton – momentary
1
1
2
2
I
I
O
O
–
–
–
–
White
Green
Black
Red
–
–
–
–
One 40 mm emergency stop button – twist release
6
Emerg. Stop (English) –
Red
–
1SFA 616 811 R1002
1SFA 616 811 R1001
1SFA 616 811 R1004
1SFA 616 811 R1003
0.045
0.045
0.045
0.045
1SFA 616 811 R1016
0.475
1-seat, yellow top/black bottom
One 40 mm emergency stop button – twist release
6
–
–
–
–
Red
–
1SFA 616 821 R1005
0.089
–
Green
1SFA 616 812 R1001
0.079
Green
2-seat, grey/black bottom
Two pushbuttons – momentary
2,1
O
–
l
Red
3-seat, grey/black bottom
Three pushbuttons – momentary
1, 2, 1
1SFA 616 813 R1004
0.112
Two pushbuttons – momentary – pilot lamp in centre position
Max 230 V bulb
2, 4, 1
O
l
l
Red
Clear Green
1SFA 616 813 R1001
l
O
ll
Green Red
0.116
Two pushbuttons – momentary – pilot lamp in centre position
With diode and resistor. For supply voltage 230 V AC and 130V bulb, 5911 086-15
2, 5, 1
O
I
I
Red
Clear Green
1SFA 616 813 R1003
0.121
Metallic enclosures
1-seat, grey
One pushbutton – momentary
Degree of protection IP 66.
1
–
I
–
–
Green –
1SFA 616 831 R1001
0.429
One 40 mm mushroom button – maintained – pull release
Degree of protection IP 66.
2
Emerg.stop (English)
–
Red
–
1SFA 616 831 R1018
0.452
1
Accessories, see p. 35.
Dimension drawings, see p. 60.
)
Fig. 1
34
1SFC 261001-EN, Ed. 4
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
ABB
Accessories
Contact blocks, lamp blocks and holders
Max. number
of blocks
in holder
Included
blocks
Type
Weight,
kg
Order Code
Contact blocks and lamp blocks with holder for front mounting
For non-illuminated operators
3
3
3
3
3
3
3
3
3
1 NC
1 NO
2 NC
2 NO
3 NC
3 NO
1 NC + 1 NO
2 NC + 1 NO
1 NC + 2 NO
K CBH-01
K CBH-10
K CBH-02
K CBH-20
K CBH-03
K CBH-30
K CBH-11
K CBH-12
K CBH-21
1SFA 616 600 R1110
1SFA 616 600 R1101
1SFA 616 600 R1120
1SFA 616 600 R1102
1SFA 616 600 R1130
1SFA 616 600 R1103
1SFA 616 600 R1111
1SFA 616 600 R1121
1SFA 616 600 R1112
0.019
0.019
0.032
0.032
0.045
0.045
0.032
0.045
0.045
K CBH-011
K CBH-101
1SFA 616 600 R1210
1SFA 616 600 R1201
0.034
0.034
K CBH-111
K CBH-021
K CBH-201
1SFA 616 600 R1211
1SFA 616 600 R1220
1SFA 616 600 R1202
0.047
0.047
0.047
For illuminated operators
3
3
3
3
3
1 NC + 1 LB
1 NO + 1 LB
1 NC + 1 NO
+ 1 LB
2 NC + 1 LB
2 NO + 1 LB
Single contact blocks for front mounting1)
Contact symbols
-
NO
With gold plated contacts
NC
-
LB
1 NO
1 NC
1 NO
1 NC
K CB-10
K CB-01
SK 616 001-A
SK 616 001-B
0.013
0.013
K CB-10G
K CB-01G
SK 616 007-A
SK 616 007-B
0.013
0.013
Single lamp blocks for front mounting, BA 9s base1)
For 2 W, max. 230 V AC and DC
filament bulb, neon bulb or LED.
K LB-1
SK 616 003-A
0.015
115 V AC supply voltage.
For 60 V filament bulb
max. 1.2 W
K LB-2
SK 616 003-B
0.017
230 V AC supply voltage.
For 130 V filament bulb
max. 2 W.
K LB-3
SK 616 003-C
0.020
115 V AC and DC supply voltage.
For 24 V LED
K LB-4
SK 616 003-G
0.017
24 V AC and DC supply voltage. With resistor.
Intended for electronic circuits. The resistor limits the making current
and protects against disturbances in the electronic circuit.
For 24 V filament bulb
K LB-5
SK 616 003-M
0.017
Holders
Holder for front mounting.
For three blocks
1) Contact blocks and lamp blocks
for rear mounting, see page 29.
ABB
K CBH-00
SK 616 013-F
0.006
For lamp blocks with transformer
and transformer blocks,
see page 36.
35
1SFC 261001-EN, Ed. 4
Accessories
Transformer and diode blocks
Primary
voltage
Secondary
voltage
Type
Order Code
Weight,
kg
Transformer with lamp holder for front mounting, BA 9s base
For 6 or 24 V filament bulb and 24 V LED. Rated power 1.5 W.
Intended to supply a 1.2 W filament bulb.
110 - 127 V AC
6 V AC
1SFA 616 950 R1001
220 - 250 V AC
6 V AC
1SFA 616 950 R1002
380 - 420 V AC
6 V AC
1SFA 616 950 R1003
440 - 480 V AC
6 V AC
1SFA 616 950 R1004
500 - 600 V AC
6 V AC
1SFA 616 950 R1005
110 - 127 V AC
220 - 250 V AC
380 - 420 V AC
440 - 480 V AC
24 V AC 1)
24 V AC 1)
24 V AC 1)
24 V AC 1)
1SFA 616 950 R1011
1SFA 616 950 R1012
1SFA 616 950 R1013
1SFA 616 950 R1014
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
0.095
Transformer block for illuminated operators
For 6 or 24 V filament bulb and 24 V LED. Rated power 1.5 W.
Intended to supply a 1.2 W filament bulb.
110 – 127 V AC
220 – 240 V AC
380 – 420 V AC
440 – 480 V AC
500 – 600 V AC
6 V AC
6 V AC
6 V AC
6 V AC
6 V AC
1SFA 616 950 R2001
1SFA 616 950 R2002
1SFA 616 950 R2003
1SFA 616 950 R2004
1SFA 616 950 R2005
0.095
0.095
0.095
0.095
0.095
110 – 127 V AC
220 – 240 V AC
380 – 420 V AC
440 – 480 V AC
24 V AC 1)
24 V AC 1)
24 V AC 1)
24 V AC 1)
1SFA 616 950 R2011
1SFA 616 950 R2012
1SFA 616 950 R2013
1SFA 616 950 R2014
0.095
0.095
0.095
0.095
Diode block
To be used if several lamps are to be connected to a common lamp-test pushbutton. A diode must be
connected in series with each lamp. The diode block snaps onto the lamp block or is placed at the side.
Diode block
K DB-1001
SK 616 009-A
0.015
Diagram for lamp test
1) Can be used with LED bulb.
36
1SFC 261001-EN, Ed. 4
ABB
Accessories
Bulbs. BA 9s base.
Description
Order Code
Weight
kg
Filament bulbs
Type of current: AC/DC. A lamp changing tool is required for changing bulb.
Rated
voltage
Rated
current
Rated
output
Luminance
mcd
Service
life
6V
12 V
24 V
30 V
48 V
60 V
110 V
130 V
200 mA
100 mA
50 mA
40 mA
42 mA
20 mA
18 mA
15 mA
1.2 W
1.2 W
1.2 W
1.2 W
2W
1.2 W
2W
2W
350
230
280
250
500
190
250
120
10 000 h
10 000 h
10 000 h
10 000 h
6 000 h
5 000 h
7 500 h
7 500 h
5911 086-11
5911 086-12
5911 086-13
5911 086- 4
5911 086- 5
5911 086-14
5911 086- 7
5911 086-15
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
5912 019-1
5912 019-2
5912 019-3
0.003
0.003
0.003
Neon bulbs
A lamp changing tool is required for changing bulb.
Not to be used together with green, blue or white lamp cap.
Rated
voltage
110 V
220 V
220 V
Rated
current
Current
type
Service
life
0.8 mA
0.9 mA
1.9 mA
AC/DC
DC
AC
20 000 h
20 000 h
20 000 h
LED
With one diode chip mounted on a BA 9s base.
Choose the same colour for the LED and the lamp cap or else use a clear lamp cap. White LED only with
clear lamp cap.
At DC the lamp base have to be connected to cathode (-) and the bottom contact to anode (+).
Rated
voltage
Rated
current
Colour
Type of current: (AC)/DC
24 V
24 V
24 V
24 V
24 V
1)
15 mA
15 mA
15 mA
15 mA
15 mA
1)
Wavelength
Luminance
Service life >50 000 hours.
Red
Green
Yellow
Blue
White
630 nM
525 nM
592 nM
470 nM
x=0.31
y=0.32
250 mcd
800 mcd
250 mcd
400 mcd
500 mcd
1SFA 616 921 R2021
1SFA 616 921 R2022
1SFA 616 921 R2023
1SFA 616 921 R2024
1SFA 616 921 R2025
0.005
0.005
0.005
0.005
0.005
At AC the luminance is decreased with 30 % and there is also a slight flickering
Type of current: AC Service life 25 000 hours.
110-130 V
110-130 V
110-130 V
110-130 V
110-130 V
4-6 mA
4-6 mA
4-6 mA
4-6 mA
4-6 mA
Red
Green
Yellow
Blue
White
630 nM
525 nM
592 nM
470 nM
x=0.31
y=0.32
25-35 mcd
300-350 mcd
60-90 mcd
130-150 mcd
160-200 mcd
1SFA 616 921R2131
1SFA 616 921R2132
1SFA 616 921R2133
1SFA 616 921R2134
1SFA 616 921R2135
0.005
0.005
0.005
0.005
0.005
1SFA 616 921R2221
1SFA 616 921R2222
1SFA 616 921R2223
1SFA 616 921R2224
1SFA 616 921R2225
0.005
0.005
0.005
0.005
0.005
Type of current: AC Service life 25 000 hours.
230 V
230 V
230 V
230 V
230 V
4 mA
4 mA
4 mA
4 mA
4 mA
Red
Green
Yellow
Blue
White
630 nM
525 nM
592 nM
470 nM
x=0.31
y=0.32
25 mcd
300 mcd
60 mcd
130 mcd
160 mcd
Flashing LED
A lamp changing tool is required for changing bulb.
Choose the same colour for the LED and the lamp cap or else use a clear lamp cap.
The lamp base have to be connected to cathode (-) and the bottom contact to anode (+).
Type of current DC.
Rated
voltage
Rated
current
Colour
Wave
length
24 V
24 V
24 V
25 mA
25 mA
25 mA
Red
Green
Yellow
630 nM
565 nM
585 nM
Service
life
50 000 h
50 000 h
50 000 h
4950 512-1
4950 512-2
4950 512-3
0.005
0.005
0.005
6880 311-1
0.005
Lamp changing tool
For LED and for bulbs.
ABB
37
1SFC 261001-EN, Ed. 4
Accessories
Miscellaneous
Description
Order Code
Weight
kg
Mounting tool
Used for tightening the nut of the attachment device in confined spaces.
1SFA 616 920 R8015
0.021
Membrane of silicone
Of transparent, heat and cold resistant silicon rubber. Does not harden at low temperature.
Gives IP 67 degree of protection. When membrane is used, remove the gasket.
For operator with:
Flush button
Extended button
Double pushbutton
1SFA 616 920 R8052
1SFA 616 920 R8002
SK 616 503-4
0.002
0.002
0.002
SK 615 512-1
0.002
1SFA 616 920 R8010
0.008
1SFA 616 920 R8001
0.025
Protective ring
To prevent inadvertant operation.
Not together with legend plate holder.
Protective cover
For flush button. To prevent inadvertant
operation. Not together with legend
plate holder.
Mounting kit for DIN-rail
To be used only with pushbuttons
and pilot lights
30 mm adaptors 1)
For use when fitting the 22 mm pushbutton range in 30 mm mounting holes. (1.5–4 mm panels)
For use with 22 mm Pushbuttons and Switches
Black plastic
Metal
1SFA 616 920 R8003
1SFA 616 920 R8004
0.012
0.037
For use with 22 mm Emergency Stop
Black plastic
Metal
1SFA 616 920 R8027
1SFA 616 920 R8028
0.007
0.021
For use with 22 mm Potentiometer, Compact Pilot Light and Buzzer
Black plastic
1SFA 616 920 R8029
Metal
1SFA 616 920 R8030
0.010
0.035
1)
Legend plates for 30 mm by request.
Extra key
Ronis 455 (Key code 71)
Ronis 421 (Key code 72)
Ronis 3433-E (Key code 73)
SK 616 021-71
SK 616 021-72
SK 616 021-73
0.007
0.007
0.007
Lock shackle for mushroom button with 30 mm button, twist release
Cannot be used in ABB non-metallic enclosure. For 30 mm diameter mushroom button, twist release.
Lockable with 4 padlocks when button is in the depressed position.
Max. lock yoke diameter 7 mm.
SK 615 502-D
0.080
Label sheet
For marking of contact blocks at two levels.
2949 1725-1
0.001
2154 373-2
0.001
Guide washer
To improve antirotation
38
1SFC 261001-EN, Ed. 4
ABB
Accessories
Legend plates – Survey
Fixed legend plates:
Example
Toggle switches,
two-positions
page 43
● Silver-grey aluminium
Toggle switches,
three-positions
page 43
Pushbuttons
page 40 and 44
Legend plates:
inserts:
Two-position
selector switches
page 41
Insert plates with customer/selected
text/symbols:
-See page 49
● Brushed aluminium on black plastic
● Silver-grey aluminium
● Plastic inserts with one side black and
the other white
● Plastic pocket with paper legend slip
aluminium
● Grey plastic
● Black plastic
page 48-49
Text caps:
Extended
button
Fixed plates with customer-selected
text/symbols:
-See page 41-44
Fixed plates (black/white) without text:
-See page -44
Example
● Silver-grey
Flush
button
Three-position
selector switches
page 42
Example
Pilot
light
1.
2.
3.
Example
me
rg e n c
y
E
Special legend plates:
page 46-47
Stop
● Yellow aluminium
● Yellow plastic
ABB
page 45
39
1SFC 261001-EN, Ed. 4
Accessories
Legend plates for pushbuttons
Silver-grey
Aluminium
Symbol/text
Order Code
Weight, kg
Engraved fixed legend plates, with symbols1)
O
l
ll
➞
➞
➞➞
SK 615 550-61
SK 615 550-62
SK 615 550-63
SK 615 562-12
SK 615 562-18
SK 615 562-27
0.002
0.00
0.002
0.002
0.002
0.002
Engraved fixed legend plates, with text1)
English
Close
Down
Emergency stop
Fast
Forward
In
Inching
Left
Lower
Off
On
Open
Out
Raise
Reset
Reverse
Right
Run
Slow
Start
Stop
Up
SK 615 552-13
SK 615 552-14
SK 615 552-15
SK 615 552-16
SK 615 552-17
SK 615 550-29
SK 615 552-18
SK 615 552-39
SK 615 552-20
SK 615 552-21
SK 615 552-22
SK 615 552-23
SK 615 552-24
SK 615 552-25
SK 615 552-27
SK 615 552-28
SK 615 552-40
SK 615 552-29
SK 615 552-30
SK 615 550-44
SK 615 552-31
SK 615 552-32
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
SK 615 550-12
SK 615 550-15
SK 615 550-16
SK 615 550-18
SK 615 550-19
SK 615 550-20
SK 615 550-27
SK 615 550-28
SK 615 550-29
SK 615 550-32
SK 615 550-33
SK 615 550-34
SK 615 550-35
SK 615 550-37
SK 615 550-38
SK 615 550-39
SK 615 550-44
SK 615 550-45
SK 615 550-46
SK 615 550-47
SK 615 550-48
SK 615 550-49
SK 615 550-50
SK 615 550-51
SK 615 550-52
SK 615 550-53
SK 615 550-54
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
0.002
Swedish
Back
Drift
Fel
Fram
Framryckning
Från
Hög
Höger
In
Låg
Manöverspänning
Minskar
Ned
Normal
Nödstopp
Prov
Start
Stopp
Stänger
Till
Upp
Ut
Utlösning
Vänster
Återställning
Ökar
Öppnar
1)
40
1SFC 261001-EN, Ed. 4
Text height 3 mm.
ABB
Accessories
Legend plates for two-position selector switches
Symbol/text
Silver-grey
Aluminium
Silver-Grey
Laminated plastic
Centre
Order Code
Order Code
Right
Weight, kg
Engraved fixed legend plates, with symbols1)
O
I
➞
I
II
➞➞
SK 615 550-75
SK 615 550-76
SK 615 562-72
0.002
0.002
0.002
Engraved fixed legend plates, with text1)
English
H = 39 mm
Hand
Jog
Off
Stop
Auto
Run
On
Start
SK 615 550-71
SK 615 552-52
SK 615 552-53
SK 615 552-55
0.002
0.002
0.002
0.002
SK 615 550-70
SK 615 550-71
SK 615 550-72
SK 615 550-73
SK 615 550-74
0.002
0.002
0.002
0.002
0.002
Swedish
Från
Hand
Låg
Prov
Stopp
Till
Auto
Hög
Drift
Start
Fixed legend plates with customer-selected text1)
Without heading
H = 39 mm
SK 615 999-1
SK 616 999-21
0.002
SK 616 999-22
0.002
When ordering state (in addition to Cat. No.):
– Centre text (max 5 characters)
– Right text
(max 5 characters)
H = 39 mm
With heading
H = 44.5 mm
SK 615 999-2
When ordering state (in addition to Cat. No.):
– Heading text
(max. 11 characters)
– Centre text
(max. 5 characters)
– Right text
(max. 5 characters)
H = 44.5 mm
1)
ABB
Text height 3 mm. Only the initial character is upper case unless other is stated.
41
1SFC 261001-EN, Ed. 4
Accessories
Legend plates for three-position selector switches
Symbol/text
Left
Centre
Right
Silver-grey
Aluminium
Silver-Grey
Laminated plastic
Order Code
Order Code
Weight, kg
Engraved fixed legend plates, with symbols1)
❘
➞
➞
O
O
O
❘❘
➞
➞➞
SK 615 550-81
SK 615 562-82
SK 615 562-83
0.002
0.002
0.002
Engraved fixed legend plates, with text1)
H = 39 mm
English
Hand
Slow
O
Off
Auto
Fast
SK 615 550-80
SK 615 552-60
0.002
0.002
Auto
SK 615 550-80
0.002
Swedish
Hand
O
Fixed legend plates with customer-selected text1)
Without heading
H = 39 mm
SK 615 999-1
SK 616 999-21
0.002
SK 616 999-22
0.002
When ordering state (in addition to Cat. No.):
– Left text(max 5 characters)
– Centre text
(max 5 characters)
– Right text
(max 5 characters)
H = 39 mm
With heading
H = 44.5 mm
– Heading text
– Left text
– Centre text
– Right text
H = 44.5 mm
42
1SFC 261001-EN, Ed. 4
1)
SK 615 999-2
When ordering state (in addition to Cat. No.):
(max. 11 characters)
(max. 5 characters)
(max. 5 characters)
(max. 5 characters)
Text height 3 mm. Only the initial character is upper case unless other is stated.
ABB
Accessories
Legend plates for toggle switches
Text
Silver-grey
Aluminium
Silver-Grey
Laminated plastic
Order Code
Order Code
Weight, kg
Fixed legend plates with customer-selected text1)
Toggle switches, two positions
Two text lines
H = 39 mm
SK 615 999-3
0.002
When ordering state (in addition to Cat. No.):
– Upper text (max. 4 characters)
– Lower text (max. 4 characters)
Two text lines
H = 44,5 mm
SK 615 999-4
0.002
When ordering state (in addition to Cat. No.):
– Upper text (max. 6 characters)
– Lower text (max. 6 characters)
Fixed legend plates with customer-selected text1)
Toggle switches, three positions
Three text lines
H = 39 mm
SK 615 999-3
SK 616 999-23
0.002
SK 616 999-24
0.002
When ordering state (in addition to Cat. No.):
– Upper text (max. 4 characters)
– Middle text (max. 3 characters)
– Lower text (max. 4 characters)
Three text lines
H = 44,5 mm
SK 615 999-4
When ordering state (in addition to Cat. No.):
– Upper text (max. 6 characters)
– Middle text (max. 5 characters)
– Lower text (max. 6 characters)
1)
ABB
Text height 3 mm. Only the initial character is upper case unless other is stated.
43
1SFC 261001-EN, Ed. 4
Accessories
Legend plates for pushbuttons
Silver-grey
Aluminium
Text
Order Code
Weight, kg
Fixed legend plates (for pushbuttons, mushroom buttons and pilot lights)
1)
Standard design without text
H = 39 mm
For 1-2 text lines
H = 39 mm
SK 615 540-1
0.002
For 2-3 text lines
H = 44.5 mm
SK 615 541-1
0.002
With customer-selected text1)
For 1 text line
H = 39 mm
SK 615 999-1
0.002
For 2 text lines
H = 44.5 mm
SK 615 999-2
0.002
H = 44.5 mm
Black/white
plastic
Symbol/Text
Order code
Weight, kg
Fixed legend plates
One side black and the other white. Engraving will give either white or black text.
Without text
1)
44
1SFC 261001-EN, Ed. 4
For 1-2 text lines
H = 39 mm
SK 616 540-2
0.002
For 2-3 text lines
H = 44.5 mm
SK 616 541-2
0.002
Text height 3 mm. Only the initial character is upper case unless other is stated.
ABB
Accessories
Special legend plates
Text
Order Code
Weight, kg
Emergency stop legend plate
Black text on a yellow aluminium plate. Quantity per package: 10.
Nöd Stopp
Emergency Stop
Not Aus
ARRET D'URGENCE
PARADA DE EMERGENCIA
SK 615 546-1
SK 615 546-2
SK 615 546-3
SK 615 546-4
SK 615 546-6
0.010
0.010
0.010
0.010
0.010
EMERGENCY STOP
NOT AUS
ARRET D'URGENCE
SK 615 546-13
0.010
Without text
SK 615 546-8
0.010
Black text on a yellow plastic plate. Quantity per package: 10.
Can be used as yellow background
Emergency Stop
1SFA 616 915 R1005
0.003
Legend plate without or with customer-selected text
Aluminium.
Number
of
operators
1
2
2
3
3
1
2
)
)
Max. number
of characters
per line
7
20
24
33
42
Dimensions
A
L
30.5
40
30.5
40
C
29.6
23.6
60
54
70
64
90
84
110
104
Without text 1)
Order Code
With text 2)
Order Code
SK 615 545-1
SK 615 545-2
SK 615 545-3
SK 615 545-4
SK 615 545-5
SK 615 998-1
SK 615 998-2
SK 615 998-3
SK 615 998-4
SK 615 998-5
Weight, kg
0.001
0.001
0.001
0.001
0.001
Quantity per package: 10.
When ordering state text and position (upper and lower line). Only the initial character is upper case unless other is
stated. Quantity per package: 1.
Legend plate for potentiometer
Aluminium
Design
Text
Order Code
Symbol plate
SK 615 562-87
Weight, kg
0.002
29.6 x 44.5 mm
ABB
45
1SFC 261001-EN, Ed. 4
Accessories
Text caps
Text/
Symbol
Cap
colour 1)
Flush button
Order Code
Extended button
Order Code
Pilot light
Order Code
Weight
kg
Text caps for illuminated pushbuttons and pilot lights
Flush or extended button
Till
White
1SFA 616 901R2020
1SFA 616 902R2020
1SFA 616 903R2020
0.001
Från
White
1SFA 616 901R2019
1SFA 616 902R2019
1SFA 616 903R2019
0.001
Start
White
1SFA 616 901R2030
1SFA 616 902R2030
1SFA 616 903R2030
0.001
START
Green
1SFA 616 906R1042
–
–
0.001
Can be turned 90°or 180°
Stopp
White
1SFA 616 901R2031
1SFA 616 902R2031
1SFA 616 903R2031
0.001
Characters per line
One line (line 11): max. 6
Two lines:
upper (line 21): max. 5
lower (line 22): max. 5
R
White
Black
1SFA 616 901R2019
1SFA 616 908R9009
1SFA 616 902R2019
1SFA 616 909R9009
1SFA 616 903R2019
–
0.001
0.001
On
White
1SFA 616 901R1020
1SFA 616 902R1020
1SFA 616 903R1020
0.001
ON
White
Green
Black
1SFA 616 901R1039
1SFA 616 906R1039
1SFA 616 908R1039
–
–
–
1SFA 616 903R1039
–
–
0.001
0.001
0.001
Off
White
1SFA 616 901R1019
1SFA 616 902R1019
1SFA 616 903R1019
0.001
OFF
White
Red
Black
–
–
–
1SFA 616 902R1040
1SFA 616 905R1040
1SFA 616 909R1040
–
–
–
0.001
0.001
0.001
Stop
White
1SFA 616 901R1031
1SFA 616 902R1031
1SFA 616 903R1031
0.001
STOP
Red
1SFA 616 904R1047
1SFA 616 905R1047
–
0.001
Reset
White
1SFA 616 901R1025
1SFA 616 902R1025
1SFA 616 903R1025
0.001
Ein
White
1SFA 616 901R6020
1SFA 616 902R6020
1SFA 616 903R6020
0.001
Aus
White
1SFA 616 901R6019
1SFA 616 902R6019
1SFA 616 903R6019
0.001
Without text
White
1SFA 616 901R9000
1SFA 616 902R9000
1SFA 616 903R9000
0.001
With customer
selected text2) White
1SFA 616 901R9001
1SFA 616 902R9001
1SFA 616 903R9001
0.001
Pilot light
Characters per line
One line (line 11): max. 8
Two lines:
upper (line 21): max. 8
lower (line 22): max. 8
1)
Use only white caps for illuminated pushbuttons and pilot lights
2)
When ordering, please state text and position:
- one line (middle), max. 6 characters.
- two lines (upper and lower), max. 5 or 8 characters.
Only the initial character is upper case unless other is stated.
Recommended colour combinations
of text caps and actuators
46
1SFC 261001-EN, Ed. 4
Text cap colour
Actuator
Lens colour
White
White
Pilot light
Illuminated pushbutton
All colours
All colours
Green, Red,
Black, White
Non-illuminated pushbutton
Clear
ABB
Accessories
Text caps
Text/
Symbol
Flush
button
Extended
button
Can be turned 90°or 180°
Flush button
Order Code
Extended button
Order Code
Pilot light
Order Code
Weight
kg
Text caps for illuminated pushbuttons and pilot lights
O
White
Red
Black
1SFA 616 901R9004
1SFA 616 904R9004
1SFA 616 908R9004
1SFA 616 902R9004
1SFA 616 905R9004
–
1SFA 616 903R9004
–
–
0.001
0.001
0.001
I
White
Green
Black
1SFA 616 901R9002
1SFA 616 906R9002
1SFA 616 908R9002
1SFA 616 902R9002
–
–
1SFA 616 903R9002
–
–
0.001
0.001
0.001
II
White
Green
Black
1SFA 616 901R9003
1SFA 616 906R9003
1SFA 616 908R9003
1SFA 616 902R9003
–
–
1SFA 616 903R9003
–
–
0.001
0.001
0.001
III
White
Black
1SFA 616 901R9028
1SFA 616 908R9028
1SFA 616 902R9028
–
–
–
0.001
0.001
+
White
Green
Black
1SFA 616 901R9011
1SFA 616 906R9011
1SFA 616 908R9011
1SFA 616 902R9011
–
–
–
–
–
0.001
0.001
0.001
–
White
Red
Black
1SFA 616 901R9012
1SFA 616 904R9012
1SFA 616 908R9012
–
–
–
–
–
–
0.001
0.001
0.001
White
Black
1SFA 616 901R9005
1SFA 616 908R9005
1SFA 616 902R9005
–
1SFA 616 903R9005
–
0.001
0.001
White
Black
1SFA 616 901R9014
1SFA 616 908R9014
1SFA 616 902R9014
–
–
–
0.001
0.001
White
Black
1SFA 616 901R9015
1SFA 616 908R9015
1SFA 616 902R9015
–
–
–
0.001
0.001
White
Black
1SFA 616 901R9016
1SFA 616 908R9016
1SFA 616 902R9016
–
–
–
0.001
0.001
White
Black
1SFA 616 901R9017
1SFA 616 908R9017
1SFA 616 902R9017
–
–
–
0.001
0.001
White
1SFA 616 901R9006
1SFA 616 902R9006
1SFA 616 903R9006
0.001
White
Black
1SFA 616 901R9018
1SFA 616 908R9018
1SFA 616 902R9018
–
–
–
0.001
0.001
White
Black
1SFA 616 901R9019
1SFA 616 908R9019
1SFA 616 902R9019
–
–
–
0.001
0.001
White
Black
1SFA 616 901R9020
1SFA 616 908R9020
1SFA 616 902R9020
–
–
–
0.001
0.001
White
Black
1SFA 616 901R9021
1SFA 616 908R9021
1SFA 616 902R9021
–
–
–
0.001
0.001
White
Black
1SFA 616 901R9022
1SFA 616 908R9022
1SFA 616 902R9022
–
–
–
0.001
0.001
White
Black
1SFA 616 901R9023
1SFA 616 908R9023
1SFA 616 902R9023
–
–
–
0.001
0.001
White
Black
1SFA 616 901R9024
1SFA 616 908R9024
1SFA 616 902R9024
–
–
–
0.001
0.001
White
Black
1SFA 616 901R9025
1SFA 616 908R9025
1SFA 616 902R9025
–
–
–
0.001
0.001
White
Black
1SFA 616 901R9026
1SFA 616 908R9026
1SFA 616 902R9026
–
–
–
0.001
0.001
White
Black
1SFA 616 901R9027
1SFA 616 908R9027
1SFA 616 902R9027
–
–
–
0.001
0.001
Pilot light
1)
ABB
Cap
colour 1)
Use only white caps for illuminated pushbuttons and pilot lights.
47
1SFC 261001-EN, Ed. 4
Accessories
Special legend plates
Text
Front
▲
47
Legend plates with inserts
31
Holder of grey or black plastic.
Insert of silver grey aluminium.
The insert is securely retained in a pocket and can be removed.
The inserts are available without text or with text on one or both sides.
3 mm high text in typeface Helvetica.
Weight, kg
▼
▼
36
Order Code
▲
▼
▼
Rear
Legend plate holders
Grey
Black
SK 615 564-1
SK 615 564-8
0.002
0.002
Inserts
With text/symbols
48
1SFC 261001-EN, Ed. 4
O
I
SK 615 570-30
SK 615 582-18
0.001
0.001
English
Close
On
Fast
Down
Emerg.stop
Open
Off
Slow
Up
Release
SK 615 569-10
SK 615 569-11
SK 615 569-12
SK 615 569-13
SK 615 569-14
0.001
0.001
0.001
0.001
0.001
Cancel
In
Lower
Start
Inching
Reset
Out
Raise
Stop
Jog
SK 615 569-15
SK 615 569-16
SK 615 569-17
SK 615 569-18
SK 615 569-19
0.001
0.001
0.001
0.001
0.001
Run
Forward
Full
Reverse
SK 615 569-20
SK 615 569-21
0.001
0.001
Swedish
Autom.regl
Fram
Blockering
Drift
Fel
Handregl.
Back
Deblockering
Prov
Normal
SK 615 570-10
SK 615 570-11
SK 615 570-12
SK 615 570-13
SK 615 570-14
0.001
0.001
0.001
0.001
0.001
Fort
Framryckn.
Till
Full
Nollställning
Sakta
Man.-spänning
Från
Klart
Inställning
SK 615 570-15
SK 615 570-16
SK 615 570-17
SK 615 570-18
SK 615 570-19
0.001
0.001
0.001
0.001
0.001
Hög
Höger
In
Ökar
Upp
Läg
Vänster
Ut
Minskar
Ned
SK 615 570-20
SK 615 570-21
SK 615 570-22
SK 615 570-23
SK 615 570-24
0.001
0.001
0.001
0.001
0.001
Nödstopp
Sakta ned
Start
Stänger
Utlösning
Snabbstopp
Sakta upp
Stopp
Öppnar
Återställning
SK 615 570-25
SK 615 570-26
SK 615 570-27
SK 615 570-28
SK 615 570-29
0.001
0.001
0.001
0.001
0.001
ABB
Accessories
Special legend plates
Front
Left
Rear
Centre
Right
Left
Weight
Centre
Right
Order Code
kg
Inserts for two-position selector switches Holders – see page 56
Two position. Silver grey aluminium.
l
ll
➞
➞➞
SK 615 582-72
0.001
On
High
Open
Auto
Stop
Slow
Jog
O
Start
Fast
Run
l
SK 615 569-30
SK 615 569-31
SK 615 569-32
SK 615 570-51
0.001
0.001
0.001
0.001
Till
Auto
Hög
Stopp
O
Prov
Start
l
Drift
SK 615 570-50
SK 615 570-51
SK 615 570-52
0.001
0.001
0.001
English
For two-pos. selector switch
Off
Low
Close
Hand
Swedish
Från
Hand
Låg
Inserts for three-position selector switches Holders – see page 56
Two position. Silver grey aluminium.
For three-pos. selector switch
➞
O
➞
➞
O
➞➞
SK 615 582-82
0.001
Swedish
Hand
O
Auto
l
O
ll
SK 615 569-70
0.001
O
Off
Auto
Fast
l
–
O
–
ll
–
SK 615 569-70
SK 615 569-71
0.001
0.001
English
Hand
Slow
Inserts with customer-selected text/symbols Holders – see page 56
For two-pos. selector switch
Brushed aluminium on black plastic. Engraving on the aluminium side will give black text.
Without text
With text
For three-pos. selector switch
SK 615 563-3
SK 616 999-25
0.001
0.001
SK 615 563-1
SK 615 999-5
0.001
0.001
SK 615 563-2
0.001
Silver-grey aluminium.
Without text
With text
Plastic inserts with one side black and the other white
Engraving will give either white or black text.
Without text
When ordering, please state:
1. Text (line 1, 11 or 12, max. 11 characters per line)
2. Left (line 31, max. 5 characters per line)
Centre (line 21 or 32, max. 5 characters per line)
Right (line 22 or 33, max. 5 characters per line)
3. Black or white side
4. Note: Only the initial character will be upper case unless other is stated.
Plastic pocket with paper legend slip
Consists of a pocket in which can be placed a typewritten or handwritten legend slip.
The plastic pocket is intended for insertion in the legend-plate holder. For indoor application.
ABB
Plastic pocket
SK 615 548-1
Sheet of legend slip
1 sheet=50 legend slip
SK 615 548-2
49
1SFC 261001-EN, Ed. 4
Order form – assembled stations
Non-metallic enclosures
Instructions for order form: Non-metallic enclosed pilot devices
1. Number of enclosures Only one type of enclosure per order form. Specify quantity.
2. Enclosure size
1
1
2
1
2
3
2
1
3
4
1
2
3
4
5
6
The non-metallic enclosures are available in five different sizes, intended for 1 to 6 pushbuttons/pilot
lights etc.
Specify the number of seats, 1, 2, 3, 4 or 6.
Contact blocks, lamp blocks and transformer blocks are snapped on to a built-in DIN rail in the base.
In addition to the three positions for each seat, there is further space (=position 4) for using an extra
block. See the figure below.
Max. no. of blocks= 24 for 6-seat enclosure.
Seat 1
1
2
Seat 2
3
4
1
2
Seat 3
3
4
1
2
Seat 4
3
4
1
2
Seat 5
3
4
1
2
Seat 6
3
4
1
2
3
4
❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■
3. Mode of mounting The non-metallic enclosures can be horizontally or vertically mounted. Mark the alternative of your
choice with an X.
For vertically mounted enclosures legend plates of height=39 mm can be used only. There are also
special selector switches available for vertical mounting. See page 30–31.
4. Operators
Are selected according to page 6–22. Specify the order number for the required operator.
5.1 Contact block and
lamp block
Mark the required block with an X. N.B. Normally three markings per seat. Extra blocks in shaded box.
5.2 Transformer block
Put in X against your choice. Select according to page 36. Takes up three positions. Place a blanking
plug on the mounting hole in the seat that is taken up by a transformer block. Enter the required code
letter in the sub-part of the order number.
6. Legend plates
Fixed plates and caps can be selected with text according to the legend plate section, page 40–49, with
engraved plates or customer-selected texts. Specify the order number only for catalogued options. When
ordering customised texts specify the engraving template and the required text for each line/position.
N.B. It is not possible to provide double pushbuttons with legend plates. Instead the buttons can be
marked.
7. Accessories for non-metallic enclosures
See page 29. Specify quantity and order number.
8. Accessories/Special requirements
See page 37–38. N.B. filament bulbs, neon bulbs and LEDs are not included. They are to be ordered
separately. Specify quantity and order number.
50
1SFC 261001-EN, Ed. 4
ABB
Feel free to make copies of this form. It might
come in handy at the next ordering occasion.
Non-metallic enclosed pilot devices
Order form
To
Ref.
From
Order no.
Issuer, phone
Customer
2. Mode of mounting ■
1. No. of enclosures....................in the design as below
3. Enclosure size
1-seat
■
SK 616 801-AA
Date
Horizontal
2-seat
3-seat
4-seat
6-seat
■
■
■
■
SK 616 802-AA
SK 616 803-AA
SK 616 804-AA
■
Rev.
Vertical
SK 616 806-AA
4. Operators
Seat 1
Seat 2
Seat 3
Seat 4
Seat 5
Seat 6
See page 6...22 and 30...31.
1SFA 616
....................
1SFA 616
.......................
1SFA 616
.......................
1SFA 616
.......................
1SFA 616
.......................
1SFA 616
.......................
5.1 Contact blocks, lamp blocks (for rear mounting)
Max. 3+1 block/seat
Seat 1
■ = disposable seat for extra block
N.B. normally three blocks in all per seat.
Seat 2
Seat 3
Seat 4
Seat 5
Seat 6
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
Contact block
SK 616 002-A
❑ ❑❑ ■
❑❑❑ ■
❑ ❑❑ ■
❑ ❑❑ ■
❑ ❑❑ ■
❑ ❑ ❑ ■
SK 616 002-B
❑ ❑❑ ■
❑ ❑❑ ■
❑ ❑❑ ■
❑ ❑❑ ■
❑ ❑❑ ■
❑ ❑ ❑ ■
Positions per seat
K CB -10B
K CB -01B
Lamp block
SK 616 003-D
❑
❑
❑
❑
❑
❑
SK 616 003-E
❑
❑
❑
❑
❑
❑
SK 616 003-F
❑
❑
❑
❑
❑
❑
K LB -1B
K LB -2B
K LB -3B
5.2 Transformer block N.B. A transformer block takes up three positions.
SK 615 004-.......
see page 36.
6. Legend plates
Seat 1
Seat 2
Seat 3
Seat 4
Seat 5
Seat 6
Upright
Horizontal
No. of characters per field ( )
Fixed plates 1)
Engraving template, see below
Text Heading 1(11)
Heading 2(11)
Left (5)
Upper (4)
Centre (5)
Centre (3)
Right (5)
Lower (4)
Caps with characters
Text 1 line (6)*)
Order form 1SFC 16103-55EN CRL/XM 990217
*)
2 lines
Upper (5)*)
(8) for pilot light
Lower (5)*)
Fixed plate for:
Pushbutton, pilot lights
mushroom pushbutton
Engraving template A
1) Silver-grey.
B 2)
Selector switch
2-positions
C
D 2)
Selector switch
3-positions
E
F 2)
Brushed aluminium on black plastic. Yellow for EMERGENCY STOP.
7. Accessories for non-metallic enclosures
See page 29.
Toggle
Toggle
2-positions 3-positions
G
2) Only
Caps with
1- or 2-line
text
H
for enclosures horizontally mounted.
8. Accessories/Special requirements
See page 37.
Qty .... Cable gland, incl. nut
.... Earthing device
ABB
51
1SFC 261001-EN, Ed. 4
Order form – assembled stations
Metallic enclosures
Instructions for order form: Metal-enclosed pilot devices
1. Number of enclosures Only one type of enclosure per order form. Specify quantity.
2. Enclosure size
1
2
1
2
3
2
1 4
3
3
2 6
1 5
4
The metal enclosures are available in five different sizes, intended for 1 to 6 pushbuttons/pilot lights etc.
Specify the number of seats, 1, 2, 3, 4 or 6.
Contact blocks, lamp blocks and transformer blocks are front mounted. 5-block holder can be used.
3. Operators
Are selected according to page 6-22. Specify the order number for the required operator.
4.1 Contact block and
lamp block
Mark the required block with an X. N.B. Normally three markings per seat.
4.2 Transformer block
Put in X against your choice. Select according to page 36. Takes up three positions. Place a blanking
plug on the mounting hole in the seat that is taken up by a transformer block. Enter the required code
letter in the sub-part of the order number.
5. Legend plates
Fixed plates and caps can be selected with text according to the legend plate section's options with
engraved plates or customer-selected texts. Specify the order number only for catalogued options.
When ordering customised texts specify the engraving template and the required text for each line/
position. N.B. It is not possible to provide double pushbuttons with legend plates. Instead the buttons
can be marked.
6. Accessories for metal-enclosures
See page 33. Specify quantity and order number.
7. Accessories/Special requirements
See page 37–38. N.B. filament bulbs, neon bulbs and LEDs are not included. They are to be ordered
separately. Specify quantity and order number.
52
1SFC 261001-EN, Ed. 4
ABB
Feel free to make copies of this form. It might
come in handy at the next ordering occasion.
Metal-enclosed pilot devices
Order form
To
Ref.
Date
From
Order no.
Issuer, phone
Customer
Rev.
1. No. of enclosures....................in the design as below
2. Enclosure size
1-seat
■
SK 616 701-AA
2-seat
3-seat
4-seat
6-seat
■
■
■
■
SK 616 702-AA
SK 616 703-AA
SK 616 704-AA
SK 616 706-AA
3. Operators
Seat 1
Seat 2
Seat 3
Seat 4
Seat 5
Seat 6
See page 6...22.
1SFA 616
........................
1SFA 616
.......................
1SFA 616
.......................
1SFA 616
.......................
1SFA 616
.......................
1SFA 616
.......................
4.1 Contact block, lamp block (for front mounting) N.B. Max. three blocks in all per seat with 3-block holders..
Seat 1
Seat 2
Seat 3
Seat 4
Seat 5
Seat 6
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
1 2 3
Contact block
SK 616 001-A
❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
SK 616 001-B
❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
❑ ❑ ❑
Lamp block
SK 616 003-A
❑
❑
❑
❑
❑
❑
SK 616 003-B
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
Position 3-block holder
K CB -10
K CB -01
K LB -1
K LB -2
SK 616 003-C
K LB -3
4.2 Transformer block
N.B. A transformer block takes up three positions.
SK 615 004-.......
see page 36.
5. Legend plates
Seat 1
Seat 2
Seat 3
Seat 4
Seat 5
Seat 6
Upright
Horizontal
No. of characters per field( )
Fixed plates 1)
Engraving template, see below
Text Heading 1(11)
Heading 2(11)
Left (5)
Upper (4)
Centre (5)
Centre (3)
Right (5)
Lower (4)
Caps with characters
Text 1 line (6)*)
2 lines
(8) for pilot light
Order form 1SFC 16103-57EN CRL/XM 990217
*)
Upper (5)*)
Lower (5)*)
Fixed plates for:
Pushbutton, pilot lights Selector switches
mushroom pushbutton 2-positions
Engraving template
A
1) Silver-grey.
B2)
C
D 2)
Selector switches
3-positions
E
F 2)
Toggle
Toggle
2-positions 3-positions
G
Caps with
1- or 2-line
text
H
Brushed aluminium on black plastic. Yellow for EMERGENCY STOP. 2) Only for enclosures horizontally mounted.
6. Accessories for metal enclosures
See page 33.
7. Accessories/Special requirements
See page 37-38.
Qty .... Cable gland, incl. nut
.... Earthing device
.... Cover plate with n no. of bushings
ABB
53
1SFC 261001-EN, Ed. 4
Technical data
Approvals
The pushbuttons and pilot lights are approved by:
– national approval agencies: VDE, UL*) and CSA*)
– marine classification: Lloyds, Bureau Veritas, Det Norske Veritas,
Germanische Lloyd and Maritime Register of Shipping (Russia).
Material and characteristics
No ozone depleting substances in the products.
Material1)
Standards
PC PSU PA PBT Zink Light- Rubber
alloy Chloro- Nitrile
prene
IEC 73, 529, 947-5-1, 947-5-5
EN 50 013, 60 947-5-1
VDE 0660 part 2
UL 508
CSA C22.2 No. 14
*)
Pushbutton
● ●
● ●
●
●
Double pushbutton
● ●
● -
-
-
-
●
Mushroom pushbutton,
momentary
maintained
● ●
● -
● ● -
-
-
●
-
●
●
Emergency stop
● -
● ●
-
-
●
●
Potentiometer
● -
● -
-
-
-
●
IP 66
IP 66
IP 54
IP 66
IP 54
IP 64
Selector switch
● ●
● -
-
-
-
●
Toggle switch
● -
● -
-
-
-
●
Pilot light
● -
● -
-
-
-
●
Lock in lockable operators
-
-
-
-
●
-
-
-
Non-metallic enclosure
● -
-
-
-
-
●
-
IP 43
IP 66
IP 54
IP 43
IP 66
IP 65
IP 66
IP 54
IP 65
Metallic enclosure
-
-
-
-
●
●
-
For detail information please contact ABB
Degrees of protection
Operators
Pushbutton with flush or extended button
Mushroom pushbutton, momentary
Mushroom pushbutton, maintained
Emergency stop pushbutton
Double pushbutton
Reset button
Lockable pushbutton and
lockable mushroom pushbutton
Selector switch
Key operated selector switch
Toggle switch
Pilot lights
Buzzer
Potentiometer
Signal Tower K70
Signal Beacons
Electrical functions
Contact block and transformer block
IP 20
1)
Material
Characteristics
PC
Polycarbonate
High impact strength, good outdoor resistance. Can withstand light acid solutions,
aliphatic hydrocarbons, paraffin, alcohols,
animal and vegetable greases.
PSU
Polysulphone
Can withstand high temperatures, acids,
basic solutions, alkaline compounds,
oils, alcohols.
PA
Polyamide
Can withstand high temperatures, aliphatic, aromatic and chlorinated hydrocarbons, esters, ketone-aldehydes,
alcohols and basic solutions.
Enclosures
Polycarbonate enclosures (Non-metallic)
IP 65
Light-alloy enclosures (Metallic)
(with sealing membrane)
IP 67
54
1SFC 261001-EN, Ed. 4
-
PBT
Can withstand temperature, aliphatic and
aromatic hydrocarbons, acids, basic
solutions, alcohols, grease and oils
Zinc
Good corrosion resistance in inland-,
sea and industrial atmosphere.
Light-alloy
Good corrosion resistance in inland-,
sea and industrial atmosphere.
ABB
Technical data
Mechanical life
Lamp block
Operators
Ratings as per IEC 947-5-1
Rated insulation voltage
Base
Max. permissible power
Pushbuttons with flush or extended button,
momentary mushroom pushbutton
2 million operations
Selector switch, maintained mushroom pushbutton, key operated selector switch and
double pushbutton
0.5 million operations
Emergency stop pushbutton
0.1 million operations
Toggle switch
1 million operations
Lockable pushbuttons
0.3 million operations
Service life of filament bulb
Relative service life, luminous flux and power consumption
at different service voltages.
It is generally true to say that bulbs for lower voltages give more light and
have better vibration-withstand capability than bulbs for higher voltages.
Service life
Temperature
Ambient temperature during operation
Exception: All pilot devices with 2 W
continuously lit filament bulb
Storage temperature
230 V
BA 9s
2W
a = service life (H)
b = luminous flux (lm)
c = power (W)
Ud = service voltage, V
Um= bulb voltage (V)
-25 to +70 °C
-25 to +40 °C
-30 to +85 °C
Terminals
Plus-minus pozidrive size 2 screw with DIN-washer.
Connectable area
min. 1 x 0,5 mm2
max. 2 x 2,5 mm2
Recommended torque
0,9 Nm
10 million operations
Self cleaning contacts of silver, NC contact has forced breaking.
At voltages and currents below 24 V and 5.6 mA two contact blocks in
parallel are recommended. As an alternative, gold plated contacts are
recommended.
Ratings as per UL/CSA, NEMA A 600, Q600
Rated insulation voltage
Rated thermal current
Rated operational current at
120 V
240 V
480 V
600 V
Ratings as per IEC 947-5-1
Rated insulation voltage, Ui
Rated thermal current, Ith
Rated operational current, Ie
utilisation category AC 15, at
120 V
230 V
400 V
690 V
Rated operational current, Ie
utilisation category DC 13, at
24 V
125 V
250 V
Contact resistance
600 V
10 A
6A
3A
1.5 A
1.2 A
690 V
10 A
8A
6A
4A
2A
5A
1.1 A
0.55 A
25 mΩ
Max. number of contact blocks per operator 1)
Pushbutton, toggle switch
6
Mushroom pushbutton
5
Double pushbutton, selector switch and
key operated selector switch, emergency
stop pushbutton
4
1)
Lamp comparisation
Bulb
type
Contact blocks
Mechanical endurance
Ud/Um
Approx.
service
life (hours)
Shock and
vibration
immunity
High
operating
temperature
Low power
Brightness
consumption
Filament 5000–
10 000
+
+
+
+++
Neon
20 000
++
+++
+++
+
LED
25 000–
50 000
+++
++
++
++
Very good +++
Good
++
Less good +
Lens colours suitable for:
Red
Green
Yellow
Blue
White
Clear
Filament
bulbs
LEDs
Neon
bulbs
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Transformer block
Suitable for filament bulb 6 or 24 V AC and 1.2 W and LED 24 V.
Rated power
1.5 W
Rated voltage
Ratio, see
Accessories page 36
Rated insulation voltage acc. to IEC
70 °C (∆T)
Class E
The contact blocks can be stacked in max. two levels.
Short circuit protection
Max. fuse at 1 kA
ABB
16 A ordinary
10 A delayed
55
1SFC 261001-EN, Ed. 4
Dimensions
Pushbutton
Key-lockable pushbutton
Mushroom pushbutton
R29
Flush
Ø29
23
1,5-6
43
Ø60
Ø40
30
56
25,5
25,5
Extended
Emergency Stop pushbutton
Double pushbutton
Selector switch
Key-operated selector switch
Toggle switch
Potentiometer
Pilot light
Pilot light with transformer
Compact Pilot Light
Ø29
Ø29
Dimensions in mm.
56
1SFC 261001-EN, Ed. 4
ABB
Dimensions
Buzzer
Transformer block
90
50
30
5
29
Drilling plans for pushbuttons,
switches and pilot lights
Drilling plan for
double pushbutton
Drilling plan for 30 mm adaptor
1)
30
2)
1)
55 mm when legend plate H= 44.5 mm is used.
61 mm for mushroom pushbutton with D=60 mm
2)
37 mm when legend plate with insert is used,
30
Mounting on a DIN-rail
ABB
57
1SFC 261001-EN, Ed. 4
Dimensions
Contact box for cable exit at side
Signal Tower K 70
Base for tube, plastic
ø 70
ø 70
Rubber
seal
15°
2
4.
54
ø
5.
5
15
43
ø
PG 11
Base for tube, metal
Contact box with magnetic base
Base with integrated tube
184
240
56
296
352
32
46
408
PG 11
110
85
ø 25
ø 70
ø 10.5
54
ø 5.5
ø 70
Audible module
Bracket 1-sided mounting
69
70
ø 70
Bracket 2-sided mounting
Drilling plan for Signal Tower K 70
54
58
1SFC 261001-EN, Ed. 4
ABB
Dimensions
Signal Beacons K SB
Drilling plan for Signal Beacons
39
7
16
32
3
64.5
ø 68
22
Pg29 (ø 37)
ø 75
Screw terminal
M3
ABB
Pull relief
59
1SFC 261001-EN, Ed. 4
Dimensions
Dimensions in mm.
Enclosures, non-metallic
1 seat
2 seats
3 seats
Ø 4.8 (2x)
Ø 4.8 (2x)
Ø 4.8 (2x)
1)
1)
1)
2)
6 seats
4 seats
Ø 4.8 (2x)
23.6
Ø 4.8 (2x)
1)
1)
2)
Enclosures, metallic
1 seat
2 or 3 seats
1) Knock-outs in the bottom
2) Both sides identical. Knock-outs, D = 22.5 or 28.6
60
1SFC 261001-EN, Ed. 4
4 or 6 seats
ABB
ABB
61
1SFC 261001-EN, Ed. 4
ABB agencies and representatives
throughout the world
Europe
AUSTRIA
NORWAY
ABB Control AS
Component Division
Kjellstad, Näringssenter
N - 3400 LIER
Phone : (47) 32858050
Fax
: (47) 32858010
POLAND
ABB Industrial Components Ltd
ul. Marywilska 22
PL - 03 228 WARSAW
Phone : (48) 226760400
Fax
: (48) 226760440
PORTUGAL
ABB Componentes Eléctricos SA
Estrada do Casal de Canas
Edificio ABB Alfragide
P - 2700 AMADORA
Phone : (351) 14169200
Fax
: (351) 14169250
ROMANIA
ABB Ltd
Street I. Cimpineanu 16
P.O. Box 1.-871-5th Floor
RO - 70100 BUCHAREST
Phone : (40) 13300495
Fax
: (40) 13300630
ABB Industrie & Gebäudesysteme GmbH
(ATIGS)
Div. ABB Serienprodukte
Wienerbergstrasse 11B
P.O. Box 184 A
AT - 1810 WIEN
Phone : (43) 1601090
Fax
: (43) 1601098600
BELGIUM
ABB Electro N.V.
Hoge Wei 27
B - 1930 ZAVENTEM
Phone : (32) 27186311
Fax
: (32) 27186666
BULGARIA
ABB Ltd
5, Triaditsa street
BG - 1040 SOFIA
Phone : (359) 29800450
Fax
: (359) 29800846
CROATIA
ABB
Trg. J.F. Kennedya 7
HR - 41000 ZAGREB
Phone : (385) 12335355
Fax
: (385) 1228836
RUSSIA
ABB Industrial & Building Systems
23, Profsoyuznaya street
RU - 117 859 MOSCOW
Phone : (7) 0951209004
Fax
: (7) 0951204490
CZECH REPUBLIC ABB EJF, a.s.
Hybesova 30
CZ - 60200 BRNO
Phone : (42) 543216742
Fax
: (42) 5331489
SLOVAKIA
ABB STOTZ Krompachy s.r.o.
Hornadska ul. 1
SK - 053 42 KROMPACHY
Phone : (42) 965972181
Fax
: (42) 956971094
DENMARK
ABB Komponent A/S
Helgeshoj Allé 8-10
P.O. Box 230
DK - 2630 TAASTRUP
Phone : (45) 43595959
Fax
: (45) 43595950
SLOVENIA
ABB Electrocomponentes SA
Dunajska 22
SL- 1000 LJUBLJANA
Phone : (386) 611331394
Fax
: (386) 611315067
ESTONIA
ABB Eesti
Pärnu mnt 148
EE - 0013 TALLINN
Phone : (372) 6711800
Fax
: (372) 6711814
SPAIN
ABB Metron S.A.
Torrent de l'Olla, 220
E - 08012 BARCELONA
Phone : (34) 34842121
Fax
: (34) 34842190
FINLAND
ABB Control Oy
P.O. Box 622
SF - 65101 VAASA
Phone : (358) 010224000
Fax: (358) 0102245708
SWEDEN
ABB Control AB
Saltängsvägen 26
S - 721 61 VASTERAS
Phone : (46) 21320700
Fax
: (46) 21126001
FRANCE
ABB Diffusion S.A.
10, rue Ampère - Z.I., B.P. 114
FR - 69685 CHASSIEU Cedex
Phone : (33)4 72221992
Fax
: (33) 4 78902758
SWITZERLAND
ABB CMC Components
Badenerstrasse 790
CH - 8048 ZÜRICH
Phone : (41) 14356600
Fax
: (41) 14356601
GERMANY
ABB SST
Eppelheimer Strasse 82
D - 69123 HEIDELBERG
Phone : (49) 62217770
Fax
: (49) 6221777111
TURKEY
ABB Elektrik Sanayi A.S.
Yukari Dudullu Imes P.O. Box 3
TR - 81260 UMRANIYE-ITANBUL
Phone : (90) 2163652900
Fax
: (90) 2163652940
GREECE
ABB Trade S.A.
13th Klm National Road Athens-Lamia
GR - 144 52 Metamorphossis ATTICA
Phone : (30) 12891900
Fax
: (30) 12891999
Phone : (44) 203368500
Fax
: (44) 203364499
HUNGARY
ABB Ltd
Vaci ut 152 - 156
P.O. Box 95
HU - 1138 BUDAPEST
Phone : (36) 12701555
Fax
: (36) 12698723
UNITED KINGDOM ABB Control Ltd
Grovelands House
Longford Road - Exhall
GB - COVENTRY CV7 9ND
YUGOSLAVIA
Phone : (381) 11344341
Fax
: (381) 11341623
ICELAND
Johan Ronning HF
Sundaborg 15
IS - 105 REYKJAVIK
Phone : (354) 5684000
Fax
: (354) 5688221
IRELAND
ABB Ltd
Belgard Road
TALLAGHT - DUBLIN 24
Phone : (353) 4057300
Fax
: (353) 4057327
ISRAEL
S Kahane Agencies. Ltd
1.Haomanviot Str.
IL - NETANYA 42160
Phone : (972) 9 8851311
Fax
: (972) 9 8851240
ITALY
ABB Elettrocondutture S.p.A
Viale Dell' Industria 18
I - 200 10 VITTUONE
Phone : (39) 2 9034 1
Fax
: (39) 2 9034 7609
LATVIA
ABB Latvia SIA
15 Krustpils street
LV - 1073 RIGA
Phone : (371) 2249087
Fax
: (371) 9341877
LITHUANIA
ABB UAB
Lukiskiu 5
LT - 2600 VILNIUS
Phone : (370) 822224831
Fax
: (370) 822224693
LUXEMBOURG
ABB S.A.
Zone Industrielle Grasbusch
L - 3370 LEUDELANGE
Phone : (352) 493116
Fax
: (352) 492859
MALTA
A. CALLEJA & SONS Ltd
46, Bishop Labini Street
P.O. Box 41
MT - B'KARA
ABB Componenten BV
Lylantse Baan 9
P.O. Box 532
NL - 2908 AM CAPELLE A/D IJSSEL
NETHERLANDS
ABB
Emilijana Josimovica 4
YU - 11000 BELGRAD
Africa
EGYPT
ABB ARAB SA
7dr. Mohamed Kamel Hussein street
P.O. Box 197
Heliopolis / CAIRO
Phone : (20) 22468001
Fax
: (20) 22966776
IVORY COAST
ABB S.A.
Rue du Canal - Zone 4
P.O. Box 01 BP 1048
ABIDJAN 01
Phone : (225) 354265
Fax
: (225) 350414
KENYA
ABB
Baba Dogo Road, Ruaraka
P.O. Box 39120
NAIROBI
Phone : (254) 2861570
Fax
: (254) 2861574
NIGERIA
ABB
Industrial avenue, Plot C, Block 1
P.O. Box 21055
IKEJA (LAGOS)
Phone : (234) 14937347
Fax
: (234) 15875100
MAROCCO
Phone : (212) 2310899
: (212) 2311187
Fax
: (212) 2311121
Phone : (356) 447 448/449
Fax
: (356) 496507
ABB
119, boulevard Emile Zola
9ème étage
21700 CASABLANCA
SOUTH AFRICA
Phone : (012) 3867088
Fax
: (012) 3862422
Phone : (31) 102582250
Fax
: (31) 104586559
ABB Installation Materials (Pty) Ltd
86 Tsessebe Crescent
P.O. Box 7760
MIDRAND
TUNISIA
ABB Maghreb Services S.A.
Immeuble BADR Les Berges Du Lac
P.O. Box 381
TN - 1080 TUNIS Cedex
Phone : (27) 116533500
Fax
: (27) 116533506
ZIMBABVE
ABB Ltd
ABB House
P.O. Box 2107
88 Rezende Street
HARARE
Phone : (263) 4773594
Fax
: (263) 4753537
Phone and fax numbers do not include the code (0) for local calls in the country - The code between ( ) is the international one.
62
1SFC 261001-EN, Ed. 4
ABB Building Technologies
ABB agencies and representatives
throughout the world
America
CANADA
ABB Control
3299, Boul. J. B. Deschamps
LACHINE QCH8T3E4
QUEBEC H4S 1N6
Phone : (1) 5144203100
Fax
: (1) 514203137
U.S.A.
ABB Control Inc.
1206 Hatton Road
WICHITA FALLS TX 76302
Phone : (940) 3977000
Fax
: (940) 3977001
ARGENTINA
ABB Tubio
Tubío Tucumán S.A.
Av. Cordoba 6063
AR - 1427 BUENOS AIRES
BRAZIL
Phone : (54) 17776116
Fax
: (54) 17776116/
7725907
ABB Ltda
Av. dos Autonomistos,
1496-5 Andar
06020-902 Osasco
SAO PAULO
Phone : (55) 1170889335
Fax
: (55) 1170889977
BOLIVIA
ABB Ltda
Av. 20de Octubre No 2315
P.O. Box 9286
LA PAZ
Phone : (591) 327800
Fax
: (591) 315623
CHILE
ABB SA
Vicuna Mackenna 1602
P.O. Box 581-3
SANTIAGO
Phone : (56) 25550051
Fax
: (56) 25569345
COLOMBIA
ABB Ltda
Av. Eldorado
Carrera 100 n°. 45-A-11
P.O. Box 6195/3984
SANTAFE DÈ BOGOTA
Phone : (57) 14178036
Fax
: (57) 14134086
ABB S.A
Sucur. n° 8
Calle Ulloa 1194 y Mariana de Jesus
P.O. Box 17-08-8431
QUITO
Phone : (593) 2500645
Fax
: (593) 2500650
ABB Tecnical Office Central
69, Avda Norte 148
P.O. Box 1440
SAN SALVADOR
Phone : (503) 2986489
Fax
: (503) 2242539
ABB Mexico, S.A. de C.V.
Boulevard Centro Industrial No 12
Los Reyes Zona Industrial
Tlalnepantla, Edo. de Mexico
C.P. 54073
MEXICO CITY
Phone : (52) 53281400
Fax
: (52) 53281663
PERU
ABB S.A.
Av. Argentina 3120
LIMA
Phone : (51) 15610404
Fax
: (51) 15613040
VENEZUELA
ABB S.A.
P.O. Box 6649 - Carmelitas
Av. Don Diego Cisneros
Edif. ABB Los Ruices
CARACAS 1010 A
Phone : (58) 22382422
Fax
: (58) 22395834
HONG KONG
ABB Industrial and Building Systems Ltd
3 Dai Hei Street, Tai Po Industrial Estate
Tai Po, N.T.
HONG KONG
Phone: (852) 29293838
Fax : (852) 29293505
INDIA
ABB Ltd.
Low Voltage Apparatus Division
Plotno 5-6
Peenya Industrial Estate
IN - BANGALORE 560052
Phone : (91) 808360962
Fax
: (91) 808360349
INDONESIA
PT. Abdibangun Buana
JI. Cikini Raya 69, Building B
Tromol Pos. 3781
JAKARTA 10002
Phone : (62) 213149115
Fax
: (62) 213153964
JAPAN
ABB Industry K.K.
2-39, Akasaka 5-Chome - Minato-ku
Tokyo Central 1284
TOKYO 107
Phone : (81) 355638736
Fax
: (81) 335840483
JORDAN
Asea Brown Boveri Ltd
Al Kheir Center, 2nd fl.
P.O. Box 926 098
AMMAN 11110
Phone : (962) 6684067
Fax
: (962) 6684167
ECUADOR
EL SALVADOR
MEXICO
KOREA
ABB Ltd
P.O. Box 6131
8th Floor, Oksan Bldg
157 Samsung-Dong, Kangnam-Ku
SEOUL 135-090
Phone : (82) 25282392
Fax
: (82) 25283091
KUWAIT
ABB Electrical Co.
Commercial Area N° 1, Gulf Road
Khalid Saleh AL-Ghunaim Building
P.O. Box 4275
KW - 13043 SAFAT
Phone : (965) 2428626
Fax
: (965) 2403139
MALAYSIA
ABB Industrial and Building Systems
Sdn Bhd
No. 8A, Jalan 7/118 B
Desa Tun Razak, Cheras
56000 KUALA LUMPUR
Phone : (60) 39703398
Fax
: (60) 39726888
PAKISTAN
Ameejee Valleejee & Sons
Campbell street, P.O. Box 51
KARACHI 2
Phone : (92) 21210125
: (92) 21210129
Fax
: (92) 21737817
PHILIPPINES
ABB Industry
KM 20, South Superhighway,
Sucat, Paranaque
P.O. Box 701 Metro Manila
MAKATI
Phone : (63) 28244581
Fax
: (63) 28195762
SAUDI ARABIA
ABB Electrical Industries Ltd
P.O. Box 8796
RIYADH 11492
Phone : (966) 12653030
Fax
: (966) 12651211
SINGAPORE
ABB Industry Pte Ltd
2 Ayer Rajah Crescent
SINGAPORE 139 935
Phone : (65) 7765711
Fax
: (65) 7780222
TAIWAN
ABB Ltd
126 Nanking East Rd,
8F World Building, Section 4
P.O. Box 81-54
TAIPEI
Phone : (886) 7316090
Fax
: (886) 73355934
THAILAND
ABB T&D Ltd
322 Moo, 4 Bangpoo Industrial Estate
Soi 6, Sukuhmvit Rd
SAMUTPRAKARN 10280
Phone : (66) 23240505
Fax
: (66) 23240502
U.A.E.
ASEA Brown Boveri Ltd
P.O. Box 11070
DUBAI
Phone : (971) 4347788
Fax
: (971) 4347813
AUSTRALIA
ABB Industry Pty Ltd
Locked Bag 20
AU - REGENTS PARK NSW 2143
Phone : (61) 297382000
Fax
: (61) 297382001
NEW ZEALAND
ABB Ltd
133 Central Park Drive
P.O. Box 83203, Edmonton Henderson
NZ - AUCKLAND
Phone : (64) 98371234
Fax
: (64) 098372950
Oceania
Asia
Further information about non listed countries product availability, technical back-up and service, please consult us.
ABB Building Technologies
63
1SFC 261001-EN, Ed. 4
Colour selection
Colour selection according to IEC 73, edition 4, 1991
IEC 73 specifies colours for pushbuttons and pilot lights and gives
recommendations regarding the use of colours. An excerpt from the
standards is given below.
Colour
Pushbutton/Meaning
Pilot lights/Meaning
RED
Emergency
Measures required in emergency situations
Emergency or danger
YELLOW
Abnormal.
Measures required in abnormal situations
Abnormal or warning
GREEN
Safety
Measure to normalize or secure the situation
Normal or safety
BLUE
Prescribed
Prescribed or obligatory
WHITE, GREY,
BLACK
No special meaning prescribed
No special meaning prescribed
Pushbuttons
Emergency, even in combination with Off, is to be RED.
Stop and Off can be white, grey or black, with preference for BLACK. Red is also allowed.
Start and On can be white, grey or black, with preference for WHITE. Green is also allowed.
Start and stop in combination can be white, grey or black. Yellow, green or red must not be used.
Reset is to be blue, white, grey or black, with preference for BLUE.
Reset with stop function can be white, grey or black, with preference for BLACK. Red is also allowed.
lluminated pushbuttons
The red colour of Emergency must be on the operator itself and is not to be dependent on transmitted light.
For other functions, see Pushbuttons. When in doubt, use white (neutral).
Pilot lights
Pilot lights are to be given colours according to the table above. When in doubt, use white (neutral).
64
1SFC 261001-EN, Ed. 4
ABB
Index of Cat. Nos.
Order Code
Page
2154 373
2949 1725
4950 512
38
38
37
5911 086
5912 019
5396 0543
37
37
29
5396 0562
6880 311
27
37
1SFA 616
070
071 – 079
080, 087
24
25
26
100 – 103
110 – 116
124 – 125
6, 7
11
12
130 – 137
141 – 148
147 – 148
8, 9
8, 10
8, 10
200 – 205
210 – 217
220 – 222
16, 18
17, 19
30
230 – 232
280 – 287
300 – 302
31
20
21
400 – 402
410
500, 501, 504
22
15
13
Order Code
1SFA 616
SK 170
K A70
K ASB
K ASI
KB
K B70
K CB
K CBH
K CBHS
K DB
KL
K L70
K LB
KP
K PD
ABB
Page
25
26
25
22
25
29, 35
22, 35
14
36
22
24
29, 35
6-7
8 - 10
811 – 813
821, 831
901 – 909
34
34
46, 47
915
920
921
45
22, 29, 38
37
922
923
950
26
24
36
4536
7685, 7686, 7687
33
33
Order Code
Page
SK 616 001
002
003
35
29
29, 35
007
008
009
35
29
36
013
021
204
35
38
27
27
29, 33
38
SK 172 105
33
404
502
503
SK 175 919
923
931
33
29
29
540, 541
590
701 – 704, 706
33
801 – 804, 806
28
999
41, 42, 43, 49
0152
SK 615 017
502, 512
516
29
38
29
540 – 541
545, 546
548
550, 552
562
563
999
44
29
32
44
45
49
40, 41, 42
40, 41, 42, 45
49
564
569, 570, 582
998
510, 511, 513, 514
14
600
22, 35
605
14
Type
Page
48
48, 49
45
41, 42, 43, 44
Type
K PK
K PM.-...
K PMT.-..., K PMK.-...,
K PMP.-...
K S70
K SB
K 2SS.-...
K 3SS.-...
K 2SSK.-..., K 3SSK.-...
K 2SSV.-...
K 3SSV.-...
KT
K T70
K TS
Page
11
12
13, 14
25
26
16, 18
17, 19
20
30
31
15
25
21
65
1SFC 261001-EN, Ed. 4
Explanation of type designations
Explanation of type designation
Buzzers, contact blocks, lamp blocks, siren, Signal Beacons etc
Example 1:
Type K CBH-1110
B
CB
CBH
LB
Buzzer
Contact Block
Contact Block with Holder
Lamp Block
S70
SB
A70
ASI
Siren (to K70)
Signal Beacon
Accessories to K70
AS-Interface Module to K70
Pilot lights, Signal Towers
Example 2:
Type K L1-100R
L1
L2
Pilot Light Head
Compact Pilot Light
L70
Light element K70
Lens colour:
R = Red
W = White
G = Green B = Black
Y = Yellow C = Clear
L = Blue
U = Grey
Operators
Example 3:
Type K PM1-10Y
P
PD
PK
PM
PMT
PMK
PMP
2SS
3SS
T
TS
Example 4:
Pushbutton
Pushbutton, Double
Pushbutton, Key-lockable
Pushbutton, Mushroom
Pushbutton, Mushroom, Twist release
Pushbutton, Mushroom, Key-lockable
Pushbutton, Mushroom, Pull release
2-pos. Selector Switch
3-pos. Selector Switch
Potentiometer
Toggle Switch
Button colour/
Lens colour for double pushbuttons
R = Red
W= White
G = Green B = Black
Y = Yellow C = Clear
U = Grey
Y = Blue
Type K 2SSK1-10■
PK
Pushbutton, Key-lockable
2SSK 2-pos. Selector Switch, Key-lockable
3SSK 3-pos. Selector Switch, Key-lockable
K= "Generation"
66
1SFC 261001-EN, Ed. 4
Key code ■ :
1 = 71
2 = 72
3 = 73
K
ABB
ABB
67
1SFC 261001-EN, Ed. 4
ABB Control AB, SE-721 61 Västerås, Sweden, Telephone +46 21 32 07 00, Telefax +46 21 12 60 01
Catalogue 1SFC 261001-EN, Ed.4 December 2000 ABB Control/XM Printed in June 2001
Download