Installation Instructions

advertisement
4 Channel Passive Video UTP Transceiver Hub
Installation Instructions
General
This manual is a guide to the installation and operation of the VID-HUB-04P model VIDIPAC UTP.
Please read the entire manual before installing.
Brief description
VID-HUB-04P model is a 4-channel passive transceiver hub with RJ45 and Terminal block UTP cable connection. This passive
hub has built-in transient protection and excellent anti-interference ability. VID-HUB-04P Passive Hub allows 4-CCTV video
signals to be transmitted via cost-effective Unshielded Twisted Pair (UTP) cable. Used with passive transceivers, the UTP CCTV
passive transceiver hub can connect the CCTV security and surveillance equipments using standard structured cabling
techniques for neater and more streamlined cabling instead of costly and bulky coaxial cable.
VID-HUB-04P also works in conjunction with other VIDIPAC passive transceivers and passive hubs.
Features of VID-HUB-04P
• PAL, NTSC, SECOM video compatible
• 4-channel Passive device, no power required
• Transmission range: Colour signal up to 225m* working with passive
transceivers
• RJ45 & Terminal block UTP cable connection
• BNC female connectors
• Transient protection and excellent anti-interference ability
• One year warranty
Technical specifications
Model
Video
Cable Type
Environmental
Vidipac VID-HUB-04P
Bandwidth
DC-6MHz
Insertion Loss
0.5dB
CMMR
Typically 60dB 15kHz-5MHz
Anti-transient Ability
6000V 1.2μS×50μS
Coaxial Cable
75ohm
Coaxial Connector
4 x BNC-female video connectors
UTP Connection
RJ45 and Terminal block connectors
Specification*
UTP 24AWG minimum, Cat-3 upwards, 225m* maximum
distance PAL & 300m maximum NTSC for CAT-5
Resistance
100ohm±20%
DC Loop Resistance
18ohm/100m
Differential Capacitance
62pf/m
Temperature
Operating: -20° to 70° C
Humidity
0~95%
Weight
125g
Mechanical:
Dimensions - overall of
Mechanical
balun
Weight
Dimensions - overall of
balun
Mechanical Drawing
Mechanical Drawing
Installation
143 (L) × 60mm (W) × 28mm (H)
0.125kg
*Product specifications are subject to change without notice
Length 143mm !Width 60mm ! Height 28mm
Installation
Caution
• Unshielded Twisted Pair (UTP) wires must be used. Note: Shielded twisted pair wires cause impedance mismatch
• Make sure there are no untwisted wires as it may result in distorted image and interference.
• Each video signal must use the same twisted pair.
• Make sure there are no extra branch (or star connection) of twisted pair as it results in ghost image. Always connect the
transceivers with point-to-point Unshielded Twisted Pair wires.
• Coaxial cable length between the video equipment and the passive UTP transceiver balun must not exceed 1.8m.
Transceiver installation
• Connect the VID-HUB-04P passive transceivers hub as close as possible through the coaxial cable to the video equipments
(Camera, monitors, VCRs, DVRs, etc.)
• VID-HUB-04P passive transceiver hub has RJ45 and terminal block marked ‘+’ and ‘-’ for 4-video signals.
• Use a pair of Unshielded Twisted Pair (UTP) wires to connect single video signal.
• Make sure the ‘+’ of one transceiver is connected to the ‘+’ of another transceiver and vice versa for the ‘-’ terminal.
• Make RJ45 connection according to the figure below and insert it into the RJ45 socket on the front panel of the transceiver hub.
•
Make RJ45 connection according to the figure below and insert it into
the RJ45 socket on the front panel of the transceiver hub
•
Make RJ45 connection according to the figure below and insert it into
the RJ45 socket on the front panel of the transceiver hub
•
Or make terminal block connection according to the figure below
Or make terminal block connection according to the figure below
•
Or make terminal block connection according to the figure below
Connection Diagram
Connection Diagram
Transceiver performance table for UTP video within 225m
Transceiver
Receiver
Distance
Antiinference
Power
Supply
Floating
Surge
Protection
NO
NO
YES
VID-02P
Page 4
VID-03P
VID-Hub-04P
VID-Hub-04P
Up to 225m
YES
VID-Hub-08P
VID-Hub-16P
Troubleshooting
• No Signal on the Monitor. Make sure
 Terminal are well connected
 Same pair of UTP wire is used
• Twisted image. Make Sure
 ‘+’ terminal is connected to ‘+’ and vice versa for ‘-’
• The video image is somewhat red and a red bar moves downward. Make sure
 BNC connector is well connected
 Equipments are well grounded
• The video is not stable and has ghost effect. Make sure
 There are no extra branch (or star connection) from the twisted pair
 A single length UTP wire is used
• Noisy image. Make sure
 There are no untwisted UTP wires to avoid interference
• Attenuated image. Make sure
 Coax length is less than 1.8m
 UTP length is less than 225m
• Distorted image. Make sure
 To use UTP wires Cat3 upwards to avoid impedance mismatch.
With sales and support from over 22 Locations
Download