Product Guide Roadway Edition Three Decorative Security Area Flood Controls Poles The AEL Advantage For more than 50 years, American Electric Lighting (an Acuity Brands Company) has produced the highest quality outdoor, utility, and infrastructure lighting products. Continuing in our tradition of excellence, Edition Three of the AEL Product Guide offers a complete package of products for these applications, including Roadway, Decorative, Area, Security, and Floodlighting luminaires, as well as Poles and Photocontrols. However the real AEL Advantage extends beyond our product breadth…it’s the quality and innovation in our products…it’s our knowledgeable sales, service and support teams …and it’s the reliability of our delivery and product performance. Read on for more about the AEL Advantage. Nighttime FriendlyTM In response to the increased demand for products that reduce light pollution, Acuity Brands Lighting established the “Nighttime Friendly” designation to recognize products across our brands that minimize light pollution. Nighttime Friendly products provide superior optical control consistent with the goals of USGBC LEED® and Green Globes™ product criteria for light pollution reduction. Products marked as Nighttime Friendly must meet stringent photometric requirements–at a minimum, these products are full cutoff and emit no more than 10% of their total lumens above 80 degrees from nadir. Look for the Nighttime Friendly logo throughout this edition of the AEL catalog. Preferred Selection Catalog Numbers Not sure what to order? These numbers (visible throughout the catalog) represent our most popular product configurations–many are available for immediate shipment. Look to these numbers for a quick-reference ordering guide. Utility-Friendly Features AEL products are designed with several utility-friendly features in mind, such as tool-less entry, tool-less adjustable photocontrol receptacles, terminal blocks, “breathing seal” gaskets, interchangeable optics, and wildlife shields. Check individual product pages for more details, or visit us at www.americanelectriclighting.com to view our Specification Sheets. Dark-to-Light (DTL) Photocontrols The AEL product offering includes Dark-to-Light Photocontrols, the leader in electronic photocontrol technology. DTL controls are available in combination with AEL products (where noted) or in stand-alone configurations. Dedicated Sales and Service Our products are marketed through a combination of sales agents and a dedicated factory sales force that targets utilities, municipalities and specifiers. Each of our sales representatives (many of whom are Lighting Certified) has intimate knowledge of their particular market, as well as our products. Our outstanding Customer Service and Tech Support teams are equally knowledgeable and friendly, and more importantly, never outsourced. Industry-Leading Warranty AEL was the first to offer a 6-year warranty on luminaire electrical components* across our entire product line and remains the industry leader on product warranties. How are we able to offer longer coverage than the competition? Put simply, we build products that perform reliably, and we stand behind the products we build. * See Terms & Conditions for full warranty information. American Electric Lighting Product Guide Edition Three We are pleased to present the third edition of the American Electric Lighting (AEL) and Dark to Light (DTL) product guide. AEL is a company on the move in the public infrastructure and utility lighting market, with products that have been successful for over 55 years in roadway, security, area, flood and decorative outdoor lighting. DTL has been a large part of that success by offering topof-the-line photocontrols. Our goal is to continue to provide the superior design, quality and reliability that our customers demand. On each product page, AEL has identified a selection of products designated as “Preferred Selection”. Products shown as “Preferred Selection” catalog numbers are frequently ordered, standard products that will be quickly shipped to satisfy your application requirements. Included in each section are ballast and optical matrices for each product. Use them to help determine the best ballast and optical configurations for your needs. Also, a selection guide has been added to the DTL pages to help you choose the best photocontrols for your application. For the most up-to-date product information, photometric files, specification sheets and other technical data that AEL and DTL have to offer, visit our website, www.americanelectriclighting.com. We at American Electric Lighting are confident this catalog will be a useful tool for you. We look forward to working with you to satisfy your lighting requirements. Thank you for your continued support. Sincerely, The AEL Team AEL “Preferred Selection” Program Preferred Selection Program AEL products are offered with an extensive list of source, ballast, optical and option choices for customers with specific application requirements. For most applications a listing of “Preferred Selection” catalog numbers is provided for each product. These products are frequently ordered and can be shipped in as little as 1 week in many cases. Consult with your AEL sales representative for actual lead time. For more information, contact Customer Service at: 1-800-754-0463 1 American Electric Lighting® Roadway Lighting TA B L E O F C O N T E N T S ROADWAY LIGHTING Product Overview ...............................10 Ordering Information ..........................11 Roadway Cobrahead Series 125 Product Overview ...............................26 Ordering Information ..........................27 Product Overview ...............................12 Ordering Information ..........................13 Roadway Cutoff Cobrahead Series 125 Product Overview ...............................28 Ordering Information ..........................29 DuraStar® Roadway Lighting System Series 20 Product Overview ...............................14 Ordering Information ..........................15 Roadway Cobrahead Series 325 Product Overview ...............................30 Ordering Information ..........................31 DuraStar® Roadway Lighting System Series 30 Product Overview ...............................16 Ordering Information ..........................17 Roadway Cutoff Cobrahead Series 325 Product Overview ...............................32 Ordering Information ..........................33 Roadway Cobrahead Series 115 Product Overview ...............................18 Ordering Information ..........................19 Roadway Cobrahead Series 327 Product Overview ...............................34 Ordering Information ..........................35 Roadway Cutoff Cobrahead Series 115 Product Overview ...............................20 Ordering Information ..........................21 Multi-Mount™ Series 285 Product Overview ...............................36 Ordering Information ..........................37 Roadway Cobrahead Series 315 Product Overview ...............................22 Ordering Information ..........................23 InterState™ II Luminaire Series 775 Product Overview ...............................38 Ordering Information ..........................39 Roadway Cutoff Cobrahead Series 315 Product Overview ...............................24 Ordering Information ..........................25 LPS Roadway/Area Luminaire Series SRX Product Overview ...............................40 Ordering Information ..........................41 CVM CVL 2 Product Guide American Electric Lighting® Roadway Lighting, Decorative Post Top Lighting TA B L E LPS Roadway/Area Luminaire Series SP2 Product Overview ...............................42 Ordering Information ..........................43 Georgian Series Underpass Series 581/681 Product Overview ...............................44 Ordering Information ..........................45 Bainbridge Series Wallpack Series 882 Product Overview ...............................46 Ordering Information ..........................47 Marietta Series SignLite Series 875 Product Overview ...............................48 Ordering Information ..........................49 Sumter Series Accessories..........................................................................50 Cresthill Classic O F C O N T E N T S Product Overview................................66 Ordering Information ..........................67 Product Overview................................68 Ordering Information ..........................69 Product Overview................................70 Ordering Information ..........................71 Product Overview................................72 Ordering Information ..........................73 Product Overview................................74 Ordering Information ..........................75 Ballast Matrices ..................................................................52 DECORATIVE AND POST-TOP LIGHTING Cresthill Sphere Product Overview................................76 Ordering Information ..........................77 Valiant® Product Overview ...............................60 Ordering Information ..........................61 American Revolution Deluxe Series Product Overview ...............................62 Ordering Information ..........................63 Cresthill Centennial Product Overview................................78 Ordering Information ..........................79 Cresthill Glass American Revolution Series 247 Product Overview................................64 Ordering Information ..........................65 Product Overview................................80 Ordering Information ..........................81 Product Guide 3 American Electric Lighting® Decorative Post Top Lighting, Security Lighting, Area Lighting TA B L E O F C O N T E N T S SECURITY LIGHTING Lexington Product Overview................................82 Ordering Information ..........................83 NEMA Head Series 11 Product Overview..........................108 Ordering Information.....................109 Product Overview................................84 Ordering Information ..........................85 NEMA Head Package Series 11 PKG Product Overview..........................110 Ordering Information.....................111 Contemporary Series 245 Product Overview................................86 Ordering Information ..........................87 Series 11 “L” Package Product Overview..........................112 Ordering Information.....................113 TwistPack Series TWT Product Overview................................88 Ordering Information ..........................89 Dusk to Dawn Series DTD Product Overview..............................114 Ordering Information ........................115 Branson Series 165 Decorative Poles Product Overview..............................116 Ordering Information ........................117 Chadsworth Series Product Overview................................90 Ordering Information ..........................91 New Albany Series Product Overview................................92 Ordering Information ..........................93 Statesboro Series Product Overview................................94 Ordering Information ..........................95 Accessories .......................................................................118 Ballast Matrices ................................................................119 AREA LIGHTING ASA Product Overview..............................122 Ordering Information ........................123 Waycross Series Product Overview................................96 Ordering Information ..........................97 Weatherproof Receptacles .............................................98 Ballast Matrices ..............................................................100 4 Product Guide PES Product Overview..............................124 Ordering Information ........................125 American Electric Lighting® Area Lighting, Floodlighting TA B L E PEM Product Overview..............................126 Ordering Information ........................127 O F C O N T E N T S LuxMaster® Classic Series LM Product Overview..............................142 Ordering Information ........................143 Accessories.......................................................................144 VMR Product Overview..............................128 Ordering Information ........................129 Ballast Matrices ...............................................................148 FLOODLIGHTING ACP Series VLR Product Overview..............................130 Ordering Information ........................131 Product Overview..............................154 Ordering Information ........................155 Product Overview..............................132 Ordering Information ........................133 UltraFloodTM Series 75 Product Overview..............................156 Ordering Information ........................157 Product Overview..............................134 Ordering Information ........................135 UltraFloodTM Series 77 Product Overview..............................158 Ordering Information ........................159 LuxMaster® Luminaire 53 Product Overview..............................136 Ordering Information ........................137 Energy Saver Series CES Product Overview..............................160 Ordering Information ........................161 LuxMaster® Luminaire 153 Product Overview..............................138 Ordering Information ........................139 Quartz Flood Series 570 Product Overview..............................162 Ordering Information ........................162 LuxMaster® Classic Series LS Product Overview..............................140 Ordering Information ........................141 Quartz Flood Series 474 Product Overview..............................163 Ordering Information ........................163 AVL-BIA AVL Product Guide 5 American Electric Lighting® Floodlighting, Photocontrols TA B L E O F C O N T E N T S AmeriSport Series ASP Product Overview .............................164 Ordering Information ........................165 D7790 Series Sportslighting Series SPF Product Overview .............................166 Ordering Information ........................167 DD Series Diagnostic Product Overview .............................182 Ordering Information ........................182 Accessories.......................................................................168 DPN Series Part Night Product Overview .............................183 Ordering Information ........................183 Ballast Matrices ...............................................................173 Product Overview .............................181 Ordering Information ........................181 ELECTRONIC PHOTOCONTROLS DP Series Silicon DBE Series Button Product Overview .............................176 Ordering Information ........................176 Product Overview .............................184 Ordering Information ........................184 DE Series Filtered Silicon Product Overview .............................177 Ordering Information ........................177 Shorting and Open Caps Product Overview .............................185 Ordering Information ........................185 DP 1704 Utility Premium Product Overview .............................178 Ordering Information ........................178 Accessories ........................................................................186 Recommendation Chart ......................................................186 ANSI Color Chart..................................................................186 DX Series Basic Product Overview .............................179 Ordering Information ........................179 DUX Series Basic Product Overview .............................180 Ordering Information ........................180 6 Product Guide American Electric Lighting® Poles, Options & Accessories TA B L E POLES O F C O N T E N T S TECHNICAL DATA Illustrated Samples .........................................................188 HPS Replacement Starters............................................232 Wind Map .........................................................................189 Lamp Selection ................................................................233 Florida Wind Rating ........................................................190 Fuse Ratings.....................................................................234 General Information........................................................191 Luminaire Classification Systems. ...............................240 RSA ...................................................................................192 Floodlighting Applications. ............................................241 RTA ...................................................................................193 Floodlight Calculations...................................................242 RSAH .................................................................................194 Roadway Lighting Application Design.........................243 SSA ...................................................................................195 Terms & Conditions.........................................................244 SSAH .................................................................................196 Index..................................................................................246 RSS ...................................................................................197 RTS ...................................................................................198 SSS ...................................................................................199 STS ...................................................................................200 STSH..................................................................................201 Pole Options .....................................................................202 Aluminum Mounting Brackets ......................................203 Steel Mounting Brackets...............................................204 RTF ...................................................................................205 RTFDB ...............................................................................206 SSF ...................................................................................207 STC ...................................................................................208 SPRTC ...............................................................................209 SPRTS ...............................................................................213 RTAU..................................................................................216 RTSU..................................................................................220 AMAW / SMAW...............................................................222 AMAC / SMAC .................................................................224 SMAWL.............................................................................226 Traditional Wood Pole Arms..........................................228 Traditional Concrete Pole Arms....................................229 Product Guide 7 NOTES 8 Product Guide ROADWAY LIGHTING Corvus™ CVM Series ..............................................10 Corvus™ CVL Series ................................................12 DuraStar® Series 20 ................................................14 DuraStar® Series 30 ................................................16 Roadway 115 ............................................................18 Roadway 115 Cutoff .................................................20 Roadway 315 ............................................................22 Roadway 315 Cutoff .................................................24 Roadway 125 ............................................................26 Roadway 125 Cutoff .................................................28 Roadway 325 ............................................................30 Roadway 325 Cutoff .................................................32 Roadway 327 .............................................................34 Multi-Mount™ 285.....................................................36 InterState™ II 775 ....................................................38 LPS Roadway - SRX .................................................40 LPS Roadway - SP2..................................................42 Underpass 581/681 ...................................................44 Heavy-Duty Wallpack 882.......................................46 SignLite 875 ...............................................................48 Accessories ..............................................................50 Ballast Matrices .......................................................52 American Electric Lighting® 9 Corvus™ Series CVM Roadway Lighting 70-250W HPS, 70-250W MH P R O D U C T O V E R V I E W Features: NEW The contemporary style of the CorvusTM CVM combines superior mechanical construction, a choice of light distributions, lamp types, and mounting options to make it a truly flexible luminaire for a variety of applications Die-cast aluminum body has direct access to the lamp and electrical components from the top Universal mounting system can be secured on a 2-3/8" to 3" O.D. vertical tenon, or on a 1-7/8” to 2-3/8” O.D. horizontal arm Using a single door entry and a standard hood support brace; full access to fixture interior including electrical gear and the optical chamber is straighforward, reducing maintenance time Tool-less lamp access and a removable power pad with quick disconnects allow for ease of gear and lamp replacement Hydroformed anodized aluminum reflector is enclosed by tempered shock resistant curved glass. The luminaire is sealed with a silicone gasket. Photocontrol receptacle is adjustable without tools reducing installation time Applications: Ambient rated 40°C outdoor City streetscapes Residential streets City streets Parking lots Campuses Optical chamber is IP66 rated standard, gear compartment is IP44 rated All electrical components warranted by American Electric Lighting's 6-year guarantee DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS CVM 10S RN 120 R2 CVM 10S CA MT1 R2 CVM 17M SC MT1 R2 CVM 25M SC MT1 R3 Effective Projected Area (EPA) The EPA for the Corvus Medium is .74 sq. ft. Approx. Wt. = 34 lbs. 10 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Corvus™ Series CVM Roadway Lighting 70-250W HPS, 70-250W MH O R D E R I N G I N F O R M AT I O N Example: C V M 1 0 S C A M T 1 R 2 Wattage / Source Series CVM Corvus Medium Architectural Cobrahead 07 70W 10 100W 13 100/150W Wired 100W 14 100W Wired 150W 15 150W 17 175W 20 200W 25 250W Voltage Distribution 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V R2 Roadway Type II R3 Roadway Type III Ballast S HPS M MH Refer to the ballast matrix on page 52 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI SC SCWA MR Mag Reg (3 Coil)1 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 Refer to optic distribution matrix below for compatibility. Options Paint (blank) BK BZ WH Gray (standard) Black Bronze White Terminal Block2 (blank) Terminal Block (standard) T2 Wired to L1 to L2 Position T3 3 Wire Operation (L1, N, L2 Position) Fusing3 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 230, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle4 Lamp LC LD Misc. BL PC SS LA 5H NN SH SC2 Lamp Included, Clear Lamp Included, Deluxe/Coated Bubble Level Photocontrol Included per Voltage Specified4 Stainless Steel Fasteners Lightning Arrestor 50 Hertz Ballast Cycle5 No NEMA Label on Housing Shorting Cap4 Cutoff optics for R2 Distribution Only Notes: 1 150W maximum 2 T3 option only available with 240, 480, DT2, DT4, MT2 3 Not available in MT, TT, DT voltages 4 PC and SH not available with NR 5 Limited availability, consult factory Optic Distribution 07S 10S 10M 15S 17M 25S 25M R2 N N N N N N N R3 N N N N N N N R2 SC2 N N N N N N N Product Guide 11 Corvus™ Series CVL Roadway Lighting 100-400W HPS, 100-400W MH P R O D U C T O V E R V I E W Features: NEW The contemporary style of the CorvusTM CVL combines superior mechanical construction, a choice of light distributions, lamp types, and mounting options to make it a truly flexible luminaire for a variety of applications Die-cast aluminum body with access to the lamp from the bottom, and a gear access canopy made of precision die-cast aluminum on the top The tool-less top-entry captive hood allows for full access to the removable electrical power pad, with quick disconnects for user-friendly gear replacement Separate tool-less optical chamber access reduces time spent during lamp exchange Universal mounting system can be secured on a 2-3/8" vertical tenon, or on a 1-5/8” to 2-3/8” O.D. horizontal arm Hydroformed anodized aluminum reflector is enclosed by tempered shock resistant curved glass. The luminaire is sealed with a silicone gasket. Photocontrol receptacle is adjustable without tools reducing installation time Applications: Optical chamber is IP66 rated standard, gear compartment is IP44 rated Roadways Residential streets City streets Parking lots Campuses Ambient rated 40°C outdoor, except for Mag Reg. All electrical components warranted by American Electric Lighting's 6-year guarantee DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS CVL 25M SC MT1 R3 CVL 40M SC MT1 R3 CVL 25S CA MT1 R3 CVL 40S CA MT1 R3 Effective Projected Area (EPA) The EPA for the Corvus Large is 1.03 sq. ft. Approx. Wt. = 43 lbs. 12 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Corvus™ Series CVL Roadway Lighting 100-400W HPS, 100-400W MH O R D E R I N G I N F O R M AT I O N Example: C V L 4 0 S C A M T 1 R 3 Wattage / Source Series CVL Corvus Large Architectural Cobrahead Voltage Distribution 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V R2 Roadway Type II R3 Roadway Type III Ballast 10 100W S HPS 13 100/150W M MH Wired 100W 14 100W Wired 150W 15 150W 17 175W 20 200W 25 250W 23 250/400W Wired 250W 24 250/400W Wired 400W 31 310W 40 400W Refer to the ballast matrix on page 52 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI SC SCWA MR Mag Reg (3 Coil) 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 Refer to optic distribution matrix below for compatibility. Options Mounting (blank) Mast Arm (standard) TT Tenon Top Paint (blank) BK BZ WH Gray (standard) Black Bronze White Terminal Block1 (blank) Terminal Block (standard) T2 Wired to L1 to L2 Position T3 3 Wire Operation (L1, N, L2 Position) Listing UL UL Listed CS CSA Certified MX NOM Listed Fusing2 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 230, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle4 Lamp LC LD Misc. 5H BL PC SS LA NN SH Notes: 1 T3 option only available with 240, 480, DT2, DT4, MT2 2 Not available in MT, TT, DT voltages 3 Limited availability - consult factory 4 PC and SH not available with NR Lamp Included, Clear Lamp Included, Deluxe/Coated 50 Hertz Ballast Cycle3 Bubble Level Photocontrol Included per Voltage Specified4 Stainless Steel Fasteners Lightning Arrestor No NEMA Label on Housing Shorting Cap4 Optic Distribution 17M 25S 25M 31S 40S 40M R1 N N N R2 N N N N N N R3 N N N Product Guide 13 DuraStar™ Series 20 Roadway Lighting 50-150W HPS, 175W MH P R O D U C T O V E R V I E W Features: Revolutionary DuraLock™ docking system provides modular installation and interchangeability for easy maintenance. Rugged die-cast, powder-coated docking station mounts securely to mast-arm to ensure secure wiring and long-lasting stability. Durable lightweight lighting fixture positively docks by plugging in with a 20° locking twist High-efficiency optical system maximizes light output while minimizing glare Starter component is externally accessible for easy maintenance and is fully encapsulated for long life Wildlife shield is cast into the docking station (not a separate piece) and is easily adjustable for 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) mast arms Cam-latch doorframe allows easy re-lamping without tools Large surface area "breathing seal" gasket, seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture Photocontrol receptacle is adjustable without tools Applications: Roadways Residential areas Coastal areas — salt/corrosive environments Parking lots Storage areas All electrical components warranted by American Electric Lighting's 6-year guarantee E39 mogul base socket standard Suitable for -30°C MH / -40°C HPS Optical chamber is IP64 rated standard Complies with ANSI: C136.2, C136.10, C136.15, C136.31 DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 20 10S RN 120 R2 FG 20 10S RN 120 R3 FG 20 15S RN 120 R2 FG Horizontal Arm Mount Vertical Tenon Mount Effective Projected Area (EPA) The EPA for the DuraStar™ is .56 sq. ft. The EPA for the DuraStar™ sag lens, is .70 sq. ft. Approx. Wt. = 14 lbs. 14 Product Guide For photometric information, visit our website, www.americanelectriclighting.com DuraStar™ Series 20 Roadway Lighting 50-150W HPS, 175W MH O R D E R I N G I N F O R M AT I O N Example: 2 0 1 0 S R N 1 2 0 R 3 F G L C P C Wattage / Source Series 20 DuraStar Cobrahead 05 07 10 15 17 50W 70W 100W 150W 175W S HPS M MH3 RN RH XN Refer to the ballast matrix on page 52 for compatibility. Voltage Ballast XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance (Lag) Normal Power Factor High Reactance (Lag) High Power Factor CWA CWI 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 Distribution 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V R2 Roadway Type II R3 Roadway Type III Refer to optic distribution matrix below for compatibility. Optics SA Sag Acrylic Lens SP Sag Polycarbonate Lens FG Flat Glass Clear Tempered4 Options Mounting (blank) Duralock Docking Station Set for 1-1/4” Mast Arm M2 2-bolt Internal 2” Setting, for Duralock Docking Station for 2” Mast Arm ML Less Duralock Docking Station VT Vertical Tenon Docking Station Misc. PC PK SS PL Paint (blank) Gray (standard) Listing UL CS UL Listed CSA Certified Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle NR No Photocontrol Receptacle1 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated 5H SH LCU Photocontrol Included per Voltage Specified1 Package (includes lamp, photocontrol, 5’ supply-wire, mast arm, hardware) Stainless Steel Fasteners (external) Distribution Pattern Indicator Label 50 Hertz Ballast Cycle2 Shorting Cap1 Low Copper Alloy Content Docking Station (less than 1%) Notes: 1 PC, SH not available with NR option 2 Limited availability, please contact your local American Electric Lighting representative 3 175W MH available standard, other wattages please contact your local American Electric Lighting representative 4 Nighttime FriendlyTM optic Optic Distribution 05S 07S 10S 15S 17M R2SA N N N N - R3SA R2SP N N N N N N N N N R3SP N N N N N R2FG N N N N - R3FG N N N N - Product Guide 15 DuraStar™ Series 30 Roadway Lighting 200-400W HPS, 175-400W MH P R O D U C T O V E R V I E W Features: Revolutionary DuraLock™ docking system provides modular installation and interchangeability for easy maintenance. Rugged die-cast, powder-coated docking station mounts securely to mast-arm to ensure secure wiring and long-lasting stability. Durable lightweight lighting fixture positively docks by plugging in with a 20° locking twist High-efficiency optical system maximizes light output while minimizing objectionable glare Starter component is externally accessible for easy maintenance and is fully encapsulated for long life Wildlife shield is cast into the docking station (not a separate piece) and is easily adjustable for 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) mast arms Die-cast trigger latch on door frame enables easy and secure one-hand opening for re-lamping and maintenance Large surface area "breathing seal" gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture Applications: Photocontrol receptacle is adjustable without tools Roadways Residential streets Storage areas Parking lots Campuses Parks All electrical components warranted by American Electric Lighting's 6-year guarantee E39 mogul base socket standard Suitable for -30°C MH / -40°C HPS Optical chamber is IP64 rated standard Complies with ANSI: C136.2, C136.10, C136.15, C136.31 DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 30 25S CA MT1 R2 FG 30 40S CA MT1 R3 FG Horizontal Arm Mount Vertical Tenon Mount Effective Projected Area (EPA) The EPA for the DuraStar™ Series 30 is 1.24 sq. ft. flat glass The EPA for the DuraStar™ Series 30 is 1.43 sq. ft. sag glass Approx. Wt. = 30 lbs. 16 Product Guide For photometric information, visit our website, www.americanelectriclighting.com DuraStar™ Series 30 Roadway Lighting 200-400W HPS, 175-400W MH O R D E R I N G I N F O R M AT I O N Example: 3 0 2 5 S C A M T 1 R 3 F G L C P C Wattage / Source Series 30 DuraStar Cobrahead 17 20 25 31 40 23 175W 200W 250W 310W 400W 250/400W Wired 250W1 24 250/400W Wired 400W1 S HPS M MH Refer to the ballast matrix on page 53 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI SC SCWA MR Mag Reg (3 Coil) 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V 5T4 5-tap wired 480V2 Distribution R2 Roadway Type II R3 Roadway Type III Refer to optic distribution matrix below for compatibility. Optics SG Sag Glass Clear Tempered FG Flat Glass Clear Tempered6 Options Mounting (blank) Duralock Docking Station Set for 1-1/4” Mast Arm M2 2-bolt Internal 2” Setting, for Duralock Docking Station ML Less Duralock Docking Station VT Vertical Tenon Docking Station Color (blank) Listing UL CS Misc. PC SS Gray (standard) PK PL UL Listed CSA Certified Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle NR No Photocontrol Receptacle3 Lamp LC LD Starter4 (blank) Externally Mounted Encapsulated Plug-In OB Open Board Internal Lamp Included, Clear Lamp Included, Deluxe/Coated 5H SH LCU Photocontrol Included per Voltage Specified3 Stainless Steel Fasteners (external) Includes Lamp, LC, PC, Arm Distribution Pattern Indicator Label 50 Hertz Ballast Cycle5 Shorting Cap3 Low Copper Alloy Content Docking station (less than 1%) Notes: 1 Not available in 5-tap 2 250W and 400W only 3 PC, SH not available with NR option 4 Available in HPS only 5 Limited availability, please contact your local American Electric Lighting representative 6 Nighttime FriendlyTM optic Optic Distribution 20S 25S 31S 40S 17M 25M 40M R2SG R3SG R2FG R3FG N N N N N N N N N N N N N N N N N N N N N N N N N N N N Product Guide 17 Roadway Series 115 Roadway Lighting 35-400W HPS, 175-250W MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) diameter. Optional four-bolt mounting provides extra security in high-vibration applications Die-cast trigger latch on doorframe enables easy and secure one-hand opening for re-lamping and maintenance Large surface area "breathing seal" gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture Wildlife shield is cast into the housing (not a separate piece) on the two-bolt unit and is easily adjustable for 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) mast arms Photocontrol receptacle is adjustable without tools Anodized aluminum reflectors provide uniform lighting distribution with borosilicate glass, acrylic, or polycarbonate refractor Applications: Roadways Residential streets Storage areas Parking lots Campuses Parks NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard All electrical components warranted by American Electric Lighting's 6-year guarantee E39 mogul base socket standard Suitable for -30°C MH / -40°C HPS Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31 DIMENSIONS 27" (686) PREFERRED SELECTION CATALOG NUMBERS 115 10S RN 120 R2 DA 115 15S CA MT1 R2 DA EC 115 15S RH 120 R2 DA 115 25S CA MT1 R3 DG EC 10.1" (257) 10.1" (257) 13" (330) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 115 is 0.9 sq. ft. Approx. Wt. = 19 lbs. 18 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 115 Roadway Lighting 35-400W HPS, 175-250W MH O R D E R I N G I N F O R M AT I O N Example: 1 1 5 1 5 S R N 1 2 0 R 2 D G L C P C Series 115 Single Door Cobrahead Ballast Wattage / Source 03 05 07 10 13 14 15 17 20 25 40 35W 50W 70W 100W 100/150W Wired 100W 100/150W Wired 150W 150W 175W 200W 250W 400W1 S M HPS MH Refer to the ballast matrix on page 53 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI SC SCWA MR Mag Reg (3 Coil) Distribution Voltage 120 208 240 277 347 480 MT1 MT8 MT2 MT7 TT3 DT2 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 208V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V R2 R3 RX Roadway Type II Roadway Type III Roadway Type II 4-way3 Refer to optic distribution matrix below for compatibility. Optics DA DP DG Drop Acrylic Prismatic Refractor Drop Polycarbonate Prismatic Refractor Drop Glass Prismatic Refractor Options Mounting (blank) 2-bolt Internal EF External Fitter (2-bolt only) 4B 4-bolt Internal M2 2-bolt Internal 2” Setting E2 External Fitter 2” Mast Arm (2-bolt only) Paint4 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 to L2 Position T3 3 Wire Operation (L1, N, L2 Position)5 Listing UL CS UL Listed CSA Certified Fusing6 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle7 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Starter1 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Misc. PC BL SS CF PL LA 5H SH HK BF RG Photocontrol Included per Voltage Specified7 Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle2 Shorting Cap7 Hinge Keeper 3G Vibration8 Rubber Silicone Optical Gasket Notes: 1 For HPS products only 2 Limited availability, please contact your local American Electric Lighting representative 3 DG option only 4 Other colors available, please contact your local American Electric Lighting representative 5 T3 option only available with 240, 480, DT2, DT4, MT2 6 Not available in MT, TT, DT voltages 7 SH, and PC not available with NR option 8 Tested to withstand 3G vibration, 4B option required Optic Distribution 03S 05S 07S 10S 15S 20S 25S 40S 17M 25M R2DA R3DA R2DP R3DP R2DG R3DG RXDG N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N Product Guide 19 Roadway Series 115 Roadway Lighting — Cutoff Style 35-250W HPS, 175-250W MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) diameter. Optional four-bolt mounting provides extra security in high-vibration applications Die-cast trigger latch on doorframe enables easy and secure one-hand opening for re-lamping and maintenance Large surface area "breathing seal" gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture Wildlife shield is cast into the housing (not a separate piece) on the two-bolt unit and is easily adjustable for 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) mast arms. Photocontrol receptacle is adjustable without tools Anodized aluminum reflectors provide uniform lighting distribution with either flat or sag clear tempered glass Applications: NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard Roadways Residential streets Storage areas Parking lots Campuses Parks All electrical components warranted by American Electric Lighting's 6-year guarantee E39 mogul base socket standard Suitable for -30°C MH / -40°C HPS Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.31 DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 115 10S CA MT1 R2 FG EC 27" (686) 6-1/2" (165) 13" (330) 6-1/2" (165) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 115 with cutoff is .74 sq. ft. Approx. Wt. = 19 lbs. 20 Product Guide Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 115 with sag glass is .82 sq. ft. For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 115 Roadway Lighting — Cutoff Style 35-250W HPS, 175-250W MH O R D E R I N G I N F O R M AT I O N Example: 1 1 5 1 5 S C A M T 1 R 3 F G L C P C H P Wattage / Source Series 115 Single Door Cobrahead 03 05 07 10 13 14 15 17 20 25 35W 50W 70W 100W 100/150W Wired 100W 100/150W Wired 150W 150W 175W 200W 250W S M HPS MH Refer to the ballast matrix on page 53 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI MR Mag Reg (3 Coil) Distribution R2 Roadway Type II 120V R3 Roadway Type III 208V 240V Refer to optic distribution 277V matrix below for compatibility. 347V 480V Multi-tap Wired 120V Optics Multi-tap Wired 240V Multi-tap Wired 277V FG Flat Glass Clear Tempered9 Tri-tap Wired 347V SG Sag Glass Clear Tempered Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 Options Mounting (blank) 2-bolt Internal EF External Fitter (2-bolt only) 4B 4-bolt Internal M2 2-bolt Internal 2” Setting E2 External Fitter 2” Mast Arm (2-bolt only) Paint2 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position)3 Listing UL CS UL Listed CSA Certified Fusing4 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle5 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Starter6 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Misc. PC BL SS CF PL LA 5H SH HK HP BF RG Photocontrol Included per Voltage Specified5 Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle1 Shorting Cap5 Hinge Keeper High Performance7 3G Vibration8 Rubber Silicone Optical Gasket Notes: 1 Limited availability, please contact your local American Electric Lighting representative 2 Other colors available, please contact your local American Electric Lighting representative 3 T3 option only available with 240, 480, DT2, DT4, MT2 4 Not available in MT, TT, DT voltages 5 PC and SH not available with NR option 6 For HPS products only 7 FG optics only 8 Tested to withstand 3G vibration, 4B option required Refer to accessory section for shield options 9 Nighttime FriendlyTM optic Optic Distribution 03S 05S 07S 10S 15S 20S 25S 17M 25M R2 SG N N N N N N N N N R3 SG N N N N N N N R2 FG N N N N N N N N1 N1 R3 FG R2 FG HPR3 FG HP N N N N N N N N N N N N N N N N1 N1 - Notes: 1 Use deluxe/coated lamp LD option Product Guide 21 Roadway Series 315 Roadway Lighting — with Power Door 35-400W HPS, 175-250W MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Die-cast secondary Power Pad door places all electrical components on one easily interchangeable module with quick disconnects to main fixture housing Two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Optional four-bolt mounting provides extra security in high-vibration applications Die-cast trigger latch on lens frame enables easy and secure one-hand opening for re-lamping Large surface area "breathing seal" gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture Wildlife shield is cast into the housing (not a separate piece) on the two-bolt unit and is easily adjustable for 1-1/4" to 2" (1-5/8” to 2-3/8” O.D.) mast arms Photocontrol receptacle is adjustable without tools Applications: Anodized aluminum reflectors provide uniform lighting distribution with borosilicate glass, acrylic or polycarbonate refractor Roadways Residential streets Storage areas Parking lots Campuses Parks NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard All electrical components warranted by American Electric Lighting's 6-year guarantee E39 mogul base socket standard Suitable for -30°C MH / -40°C HPS DIMENSIONS Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31 PREFERRED SELECTION CATALOG NUMBERS 315 10S CA MT1 R2 DA EC 315 10S RN 120 R2 DA EC 315 15S RN 120 R2 DA EC Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 315 is 0.9 sq. ft. Approx. Wt. = 19 lbs. 22 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 315 Roadway Lighting — with Power Door 35-400W HPS, 175-250W MH O R D E R I N G I N F O R M AT I O N Example: 3 1 5 1 0 S M R D T 2 R 3 D G N R B L Wattage / Source Series 315 Power Door Cobrahead 03 05 07 10 13 35W S HPS 50W M MH 70W 100W 100/150W Wired 100W 14 100/150W Wired 150W 15 150W 17 175W 20 200W 25 250W 40 400W Refer to the ballast matrix on page 54 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI SC SCWA MR Mag Reg (3 Coil) 120 208 220 240 277 347 480 MT1 MT2 MT7 TT3 DT2 120V 208V 220V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V Distribution R2 Roadway Type II R3 Roadway Type III RX Roadway Type II 4-way2 Refer to optic distribution matrix below for compatibility. Optics DA Drop Acrylic Prismatic Refractor DP Drop Polycarbonate Prismatic Refractor DG Drop Glass Prismatic Refractor Options Mounting (blank) 2-bolt Internal EF External Fitter (2-bolt only) 4B 4-bolt Internal M2 2-bolt Internal 2” setting E2 External Fitter 2” Mast Arm (2-bolt only) Paint3 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position)4 Listing UL CS Fusing5 SF DF UL Listed CSA Certified Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle6 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Starter7 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Misc. PC BL SS CF PL LA 5H NN SH HK BF RG Photocontrol Included per Voltage Specified6 Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle1 No NEMA Label on Housing Shorting Cap6 Hinge Keeper 3G Vibration8 Rubber Silicone Optical Gasket Notes: 1 Limited availability, please contact your local American Electric Lighting representative 2 DG option only 3 Other colors available, please contact your local American Electric Lighting representative 4 T3 option only available with 240, 480, DT2, DT4, MT2 5 Not available in MT, TT, DT voltages 6 SH, PC not available with with NR option 7 Available in HPS only 8 Tested to withstand 3G vibration, 4B option required Optic Distribution 03S 05S 07S 10S 15S 20S 25S 31S 40S 17M 25M R2DA R3DA R2DP R3DP R2DG R3DG RXDG N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N Product Guide 23 Roadway Series 315 Roadway Lighting — Cutoff Style with Power Door 35-400W HPS, 175-250W MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance. Die-cast secondary Power Pad door places all electrical components on one easily interchangeable module with quick disconnects to main fixture housing Two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Optional four-bolt mounting provides extra security in high-vibration applications Die-cast trigger latch on lens frame enables easy and secure one-hand opening for re-lamping Large surface area “breathing seal” gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture Wildlife shield is cast into the housing (not a separate piece) on the two-bolt unit and is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) mast arms Photocontrol receptacle is adjustable without tools Applications: Anodized aluminum reflectors provide uniform lighting distribution with either flat or sag clear tempered glass Roadways Residential streets Storage areas Parking lots Campuses Parks NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard All electrical components warranted by American Electric Lighting's 6-year guarantee E39 mogul socket standard Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.31 Suitable for -30°C MH / -40°C HPS DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 27" (686) 315 10S CA MT1 R2 FG EC 315 25S CA MT1 R2 FG EC 315 15S CA MT1 R2 FG EC 6-1/2" (165) 13" (330) 6-1/2" (165) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 315 with Cutoff is 0.98 sq. ft. Approx. Wt. = 19 lbs. 24 Product Guide Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 315 with sag glass is 1.06 sq. ft. For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 315 Roadway Lighting — Cutoff Style with Power Door 35-400W HPS, 175-250W MH O R D E R I N G I N F O R M AT I O N Example: 3 1 5 1 0 S C A D T 2 R 3 F G N R H P Wattage / Source Series 315 Power Door Cobrahead 03 05 07 10 13 35W S HPS 50W M MH 70W 100W 100/150W Wired 100W 14 100/150W Wired 150W 15 150W 17 175W 20 200W 25 250W 40 400W Refer to the ballast matrix on page 54 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI SC SCWA MR Mag Reg (3 Coil) Distribution R2 Roadway Type II 120V 208V R3 Roadway Type III 240V 277V Refer to optic distribution 347V matrix below for compatibility. 480V Multi-tap Wired 120V Multi-tap Wired 240V Optics Multi-tap Wired 277V Tri-tap Wired 277V FG Flat Glass Clear Tempered9 Tri-tap Wired 347V SG Sag Glass Clear Tempered Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V 120 208 240 277 347 480 MT1 MT2 MT7 TT7 TT3 DT2 Options Mounting (blank) 2-bolt Internal 1-1/4” Setting (standard) EF External Fitter (2-bolt only) 4B 4-bolt Internal M2 2-bolt Internal 2” Setting E2 External Fitter 2” Mast Arm (2-bolt only) Lamp LC LD Paint2 (blank) BK BZ WH UP Misc. PC Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position)3 Listing UL CS UL Listed CSA Certified Fusing4 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle5 Lamp Included, Clear Lamp Included, Deluxe/Coated Starter6 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in BL SS CF PL LA 5H NN SH HK HP BF RG Photocontrol Included per Voltage Specified5 Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle1 No NEMA Label on Housing Shorting Cap5 Hinge Keeper High Performance7 RG Vibration8 Rubber Silicone Optical Gasket Notes: 1 Limited availability, please contact your local American Electric Lighting representative 2 Other colors available, please contact your local American Electric Lighting representative 3 T3 option only available with 240, 480, DT2, DT4, MT2 4 Not available in MT, TT, DT voltages 5 PC, SH, not available in NR option 6 Available in HPS only 7 FG Optics only 8 Tested to withstand 3G vibration, 4B option required 9 Nighttime FriendlyTM optic Refer to accessory section for shield options Optic Distribution 03S 05S 07S 10S 15S 20S 25S 40S 17M 25M R2SG R3SG R2FG R3FG R2FGHP R3FGHP N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N1 N1 N N1 N1 - Notes: 1 Use deluxe/coated lamp LD option Product Guide 25 Roadway Series 125 Roadway Lighting 200-400W HPS, 175-400W MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Optional two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Standard four-bolt mounting provides extra security in high-vibration applications Die-cast trigger latch on doorframe enables easy and secure one-hand opening for re-lamping and maintenance Large surface area "breathing seal" gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture Wildlife shield is cast into the housing (not a separate piece) with 2B option and is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-2/8" O.D.) mast arms Photocontrol receptacle is adjustable without tools Anodized aluminum reflectors provide uniform lighting distribution with either borosilicate glass, or polycarbonate refractor Applications: Roadways Residential streets Storage areas Parking lots Campuses Parks NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard All electrical components warranted by American Electric Lighting's 6-year guarantee E39 mogul socket standard Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31 Suitable for -30°C MH / -40°C HPS DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 125 25S CA MT1 R3 DG EC 125 40S CA MT1 R3 DG EC 125 40M SC MT1 R3 DG Effective Projected Area (EPA) The EPA for the Horizontal Luminaire series 125 is 1.30 sq. ft. Approx. Wt. = 35 lbs. 26 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 125 Roadway Lighting 200-400W HPS, 175-400W MH O R D E R I N G I N F O R M AT I O N Example: 1 2 5 4 0 S C A M T 1 R 3 D G L C P C Wattage / Source Series 125 Single Door Cobrahead 17 20 25 31 40 23 175W 200W 250W 310W 400W 250/400W Wired 2501 24 250/400W Wired 4001 S HPS M MH Refer to the ballast matrix on page 54 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI SC SCWA MR Mag Reg (3 Coil) Distribution R2 Roadway Type II 120V R3 Roadway Type III 208V R4 Roadway Type IV 240V 277V Refer to optic distribution 347V matrix below for compatibility. 480V Multi-tap Wired 120V Optics Multi-tap Wired 240V Multi-tap Wired 277V DP Drop Polycarbonate Tri-tap Wired 347V Prismatic Refractor Dual Tap 120/240 DG Drop Glass Wired 240V Prismatic Refractor DT4 Dual Tap 240/480 Wired 480V 5T4 5-tap Wired 480V2 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 Options Mounting (blank) 4-bolt Internal (standard) M2 2-bolt Internal 2” Setting 2B 2-bolt Internal 1-1/4” Setting Paint3 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position)4 Lamp LC LD Starter7 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Misc. PC BL SS CF PL LA Listing UL CS UL Listed CSA Certified Fusing5 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle6 Lamp Included, Clear Lamp Included, Deluxe/Coated 5H NN SH HK RG Photocontrol Included per Voltage Specified6 Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle8 No NEMA Label on Housing Shorting Cap6 Hinge Keeper Rubber Silicone Optical Gasket Notes: 1 5-tap not available 2 Available in 250W and 400W 3 Other colors available, please contact your local American Electric Lighting representative 4 T3 option only available with 240, 480, DT2, DT4, MT2 5 Not available with MT, TT, DT voltages 6 PC and SH not available in NR option 7 Available in HPS only 8 Limited availability, please contact your local American Electric Lighting representative Optic Distribution 20S 25S 31S 40S 17M 25M 40M R2DP R3DP R2DG R3DG R4DG N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N - Product Guide 27 Roadway Series 125 Roadway Lighting — Cutoff Style 200-400W HPS, 175-400W MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Optional two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Standard four-bolt mounting provides extra security in high-vibration applications. Die-cast trigger latch on doorframe enables easy and secure one-hand opening for re-lamping and maintenance Large surface area “breathing seal” gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture Wildlife shield is cast into the housing (not a separate piece) with 2B option and is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) mast arms Photocontrol receptacle is adjustable without tools Anodized aluminum reflectors provide uniform lighting distribution with either flat or sag clear tempered glass Applications: Roadways Residential streets Storage areas Parking lots Campuses Parks NEMA wattage label, terminal block, and photocontrol receptacle are standard All electrical components warranted by American Electric Lighting's 6-year guarantee E39 mogul socket standard Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.31 Suitable for -30°C MH / -40°C HPS DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 125 25S CA MT1 R3 FG EC 125 40S CA MT1 R3 FG EC Effective Projected Area (EPA) The EPA for the Horizontal Luminaire series 125 Cutoff is 1.14 sq. ft. Approx. Wt. = 35 lbs 28 Product Guide Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 125 with sag glass is 1.22 sq. ft. For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 125 Roadway Lighting— Cutoff Style 200-400W HPS, 175-400W MH O R D E R I N G I N F O R M AT I O N Example: 1 2 5 4 0 S C A M T 1 R 3 F G L C P C Wattage / Source Series 125 Single Door Cobrahead 17 20 25 31 40 23 175W S HPS 200W M MH 250W 310W 400W 250/400W Wired 2501 24 250/400W Wired 4001 Refer to the ballast matrix on page 54 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI SC SCWA MR Mag Reg (3 Coil) 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 Distribution R2 Roadway Type II 120V R3 Roadway Type III 208V 240V Refer to optic distribution 277V matrix below for compatibility. 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Optics Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V 5T4 5-tap Wired 480V2 FG Flat Glass Clear Tempered10 SG Sag Glass Clear Tempered Options Mounting (blank) 4-bolt Internal (standard) M2 2-bolt Internal 2” Setting 2B 2-bolt Internal 1-1/4” Setting Paint3 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position)4 Lamp LC LD Starter7 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Misc. PC BL SS CF PL LA Listing UL CS UL Listed CSA Certified Fusing5 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle6 Lamp Included, Clear Lamp Included, Deluxe/Coated 5H SH HK HP RG Photocontrol Included per Voltage Specified6 Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle9 Shorting Cap6 Hinge Keeper High Performance8 Rubber Silicone Optical Gasket Notes: 1 Not available in 5-tap 2 Available in 250W and 400W 3 Other colors available, please contact your local American Electric Lighting representative 4 T3 option only available with 240, 480, DT2, DT4, MT2 5 Not available with MT, TT, DT voltages 6 PC, SH, not available in NR option 7 Available in HPS only 8 FG Optics only 9 Limited availability, please contact your local American Electric Lighting representative 10 Nighttime FriendlyTM optic Optic Distribution 20S 25S 31S 40S 17M 25M 40M R2SG R3SG R2FG R3FG R2FGHP R2FGHP N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N - Product Guide 29 Roadway Series 325 Roadway Lighting — with Power Door 200-400W HPS, 175-400W MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Die-cast secondary Power Pad door places all electrical components on one easily interchangeable module with quick disconnects to main fixture housing. Optional two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Standard four-bolt mounting provides extra security in high-vibration applications. Die-cast trigger latch on lens frame enables easy and secure one-hand opening for re-lamping. Large surface area “breathing seal” gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Wildlife shield is cast into the housing (not a separate piece) with 2B option and is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) mast arms. Applications: Photocontrol receptacle is adjustable without tools. Roadways Residential streets Storage areas Parking lots Campuses Parks Anodized aluminum reflectors provide uniform lighting distribution with either borosilicate glass or polycarbonate refractor. NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard. All electrical components warranted by American Electric Lighting's 6-year guarantee E39 mogul socket standard DIMENSIONS Suitable for -30°C MH / -40°C HPS Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.17, C136.31 PREFERRED SELECTION CATALOG NUMBERS 325 25S CA MT1 R3 DG EC 325 40M SC MT1 R3 DG 325 40S CA MT1 R3 DG EC 325 40M SC 480 R3 DG Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 325 is 1.30 sq. ft. Approx. Wt. = 35 lbs. 30 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 325 Roadway Lighting — with Power Door 200-400W HPS, 175-400W MH O R D E R I N G I N F O R M AT I O N Example: 3 2 5 4 0 M C A M T 7 R 3 D G B K L C Series 325 Power Door Cobrahead Wattage / Source 17 20 25 31 40 23 175W S HPS 200W M MH 250W 310W 400W 250/400W Wired 250W1 24 250/400W Wired 400W1 Refer to the ballast matrix on page 55 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI SC SCWA MR Mag Reg (3 Coil) Distribution R2 Roadway Type II 120V R3 Roadway Type III 208V R4 Roadway Type IV 240V 277V Refer to optic distribution 347V matrix below for compatibility. 480V Multi-tap Wired 120V Optics Multi-tap Wired 240V Multi-tap Wired 277V DP Drop Polycarbonate Tri-tap Wired 347V Prismatic Refractor Dual Tap 120/240 DG Drop Glass Wired 240V Prismatic Refractor DT4 Dual Tap 240/480 Wired 480V 5T4 5-tap wired 480V2 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 Options Mounting (blank) 4-bolt Internal (standard) M2 2-bolt Internal 2” Setting 2B 2-bolt Internal 1-1/4” Setting Paint3 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position)4 Lamp LC LD Starter7 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Misc. PC BL SS CF PL LA Listing UL CS UL Listed CSA Certified Fusing5 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle6 Lamp Included, Clear Lamp Included Deluxe/Coated 5H SH HK RG TL Photocontrol Included per Voltage Specified6 Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle8 Shorting Cap6 Hinge Keeper Rubber Silicone Optical Gasket Tool-less Entry to Power Pad Notes: 1 Not available in 5-tap 2 Available in 250W and 400W 3 Other colors available, please contact your local American Electric Lighting representative 4 T3 option only available with 240, 480, DT2, DT4, MT2 5 Not available with MT, TT, DT voltages 6 PC and SH, not available in NR option 7 Available in HPS only 8 Limited availability, please contact your local American Electric Lighting representative Optic Distribution 20S 25S 31S 40S 17M 25M 40M R2DP R3DP R2DG R3DG R4DG N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N - Product Guide 31 Roadway Series 325 Roadway Lighting — Cutoff Style with Power Door 200-400W HPS, 175-400W MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Die-cast secondary Power Pad door places all electrical components on one easily interchangeable module with quick disconnects to main fixture housing. Optional two-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter. Standard four-bolt mounting provides extra security in high-vibration applications. Die-cast trigger latch on lens frame enables easy and secure one-hand opening for re-lamping. Large surface area “breathing seal” gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Wildlife shield is cast into the housing (not a separate piece) with 2B option and is easily adjustable for 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) mast arms. Applications: Photocontrol receptacle is adjustable without tools. Roadways Residential streets Storage areas Parking lots Campuses Parks Anodized aluminum reflectors provide uniform lighting distribution with either flat or sag clear tempered glass. NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard. All electrical components warranted by American Electric Lighting's 6-year guarantee E39 mogul socket standard DIMENSIONS Suitable for -30°C MH / -40°C HPS Complies with ANSI: C136.2, C136.10, C136.14, C136.15, C136.31 PREFERRED SELECTION CATALOG NUMBERS 325 25S CA MT1 R3 FG EC 325 40S CA MT1 R3 FG EC Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 325 is 1.14 sq. ft. Approx. Wt. = 35 lbs 32 Product Guide Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 325 with sag glass is 1.22 sq. ft. For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 325 Roadway Lighting — Cutoff Style with Power Door 200-400W HPS, 175-400W MH O R D E R I N G I N F O R M AT I O N Example: 3 2 5 3 1 S C A M T 1 R 3 F G S F B L Wattage / Source Series 325 Power Door Cobrahead 17 20 25 31 40 23 175W 200W 250W 310W 400W 250/400W Wired 250W1 24 250/400W Wired 400W1 S HPS M MH Refer to the ballast matrix on page 55 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI MR Mag Reg (3 Coil) SC SCWA 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 DT4 5T1 5T2 5T7 5T4 Distribution R2 Roadway Type II 120V R3 Roadway Type III 208V 240V Refer to optic distribution 277V matrix below for compatibility. 347V 480V Multi-tap Wired 120V Optics Multi-tap Wired 240V Multi-tap Wired 277V FG Flat Glass Clear Tempered9 Tri-tap Wired 347V SG Sag Glass Clear Tempered Dual Tap 120/240 Wired 240V Dual Tap 240/480 Wired 480V 5-tap Wired 120V8 5-tap Wired 240V8 5-tap Wired 277V8 5-tap Wired 480V8 Options Mounting (blank) 4-bolt Internal (standard) M2 2-bolt Internal 2” Setting 2B 2-bolt Internal 1-1/4” Setting Paint2 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position)3 Lamp LC LD Starter6 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Misc. PC BL SS CF PL LA Listing UL CS UL Listed CSA Certified Fusing4 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Lamp Included, Clear Lamp Included, Deluxe/Coated 5H SH HK HP TL Photocontrol Included per Voltage Specified5 Bubble Level Stainless Steel Fasteners (external) Charcoal Filter Distribution Pattern Indicator Label Lightning Arrestor (Void UL/CSA Certified Options) 50 Hertz Ballast Cycle8 Shorting Cap5 Hinge Keeper High Performance7 Tool-less Entry to Power Pad Notes: 1 Not available in 5-tap 2 Other colors available, please contact your local American Electric Lighting representative 3 T3 option only available with 240, 480, DT2, DT4, MT2 4 Not available with MT, TT, DT voltages 5 PC and SH, not available in NR option 6 Available in HPS only 7 Available with FG optics only 8 Limited availability, please contact your local American Electric Lighting representative 9 Nighttime FriendlyTM optic Optic Distribution 20S 25S 31S 40S 17M 25M 40M R2SG R3SG R2FG R3FG R2FGHP R2FGHP N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N - Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle5 Product Guide 33 Roadway Series 327 Roadway Lighting 1000W HPS, 1000W MH P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Four-bolt mast arm mount provides easy, secure installation and adjustability for arms from 1-1/4" to 2" (1-5/8" to 2-3/8" O.D.) diameter and extra security in high-vibration applications. Die-cast trigger latch on doorframe enables easy and secure one-hand opening for re-lamping and maintenance Large surface area “breathing seal” gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heat-resistant gasket material remains effective over the life of the fixture. Anodized aluminum reflectors provide uniform lighting distribution with standard borosilicate glass refractor. Photocontrol receptacle is adjustable without tools NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard. Applications: Roadways Residential streets Storage areas Parking lots Campuses Parks All electrical components warranted by American Electric Lighting's 6-year guarantee E39 mogul socket standard Complies with ANSI: C136.2, C136.10, C136.14, C136.15 Suitable for -30°C MH / -40°C HPS DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 327 X1S CA MT1 R3 DG 327 X1M CA MT1 R3 DG 38.3" (973) 16-1/4" (413) 17-1/2" (445) 16-1/4" (413) Effective Projected Area (EPA) The EPA for the Horizontal Luminaire Series 327 is 1.96 sq. ft. Approx. Wt. = 60 lbs 34 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 327 Roadway Lighting 1000W HPS, 1000W MH O R D E R I N G I N F O R M AT I O N Example: 3 2 7 X 1 M C A M T 1 R 3 D G L C P C Wattage / Source Series 327 Single Door Cobrahead X1 1000W S HPS M MH Voltage Ballast CA CWA SC SCWA Refer to the ballast matrix on page 55 for compatibility. 120 208 240 277 480 MT1 MT2 MT7 5T4 120V 208V 240V 277V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V 5-tap Wired 480V1 Distribution R1 Roadway Type I R2 Roadway Type II R3 Roadway Type III Refer to optic distribution matrix below for compatibility. Optics DG Drop Glass Prismatic Refractor Options Paint2 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position)3 Fusing4 SF DF Single Fuse (120, 277V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle5 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Notes: 1 2 Misc. PC BL SS PL LA SH Photocontrol Included per Voltage Specified5 Bubble Level Stainless Steel Fasteners (external) Distribution Pattern Indicator Label Lightning Arrestor Shorting Cap5 3 4 5 Limited availability, please contact your local American Lighting representative Other colors available, please contact your local American Electric Lighting representative T3 option only available with 240, 480, DT2, DT4, MT2 Not available with MT voltages PC and SH not available with NR option Optic Distribution X1S X1M R1DG R2DG N N R3DG N N Product Guide 35 Roadway Series 285 Roadway Lighting — Set-Back 200-400W HPS, 250-400W MH P R O D U C T O V E R V I E W Features: Unique optical design allows set-back of mounting poles away from traffic areas, while still delivering superior performance. Light pattern allows exceptional spacing to mounting height ratios, permitting fewer luminaries per mile Anodized aluminum reflector provides uniform lighting distribution with drop acrylic prismatic refractor. Adjustable and locking knuckle mount provides for precise and secure aiming of the luminaire Suitable for 2-3/8” to 3” O.D. tenons Latch on lens frame enables easy and secure one-handed opening for re-lamping Photocontrol receptacle is adjustable without tools All electrical components warranted by American Electric Lighting's 6-year guarantee Applications: Suitable for -30°C MH / -40°C HPS Interstate roadways Broad commercial and residential roadways Large parking areas Complies with ANSI: C136.2, C136.10, C136.15, C136.31 DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 285 25S CA MT1 R3 DA GY 285 40S CA MT1 R3 DA GY Effective Projected Area (EPA) The EPA for the MultiMount™ Luminaire Series 285 is 2.8 sq. ft. Approx Wt. = 42 lbs 36 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Roadway Series 285 Roadway Lighting — Set-Back 200-400W HPS, 250-400W MH O R D E R I N G I N F O R M AT I O N Example: 2 8 5 4 0 S C A M T 1 R 3 D A L C Wattage / Source Series 285 Multi-Mount Roadway S HPS M MH 20 25 31 40 23 200W 250W 310W 400W1 250/400W Wired 250 24 250/400W Wired 4001 Voltage Ballast Refer to the ballast matrix on page 56 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI SC SCWA MR Mag Reg (3 Coil) 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 DT4 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V Dual Tap 240/480 Wired 480V Distribution R3 Roadway Type III2 Optics DA Drop Acrylic Prismatic Refractor Options Paint3 (blank) BK WH UP GY Bronze (standard) Black White Unpainted Gray Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 and L2 Positions T3 3 Wire Operation (L1, N, L2 Position)4 Fusing5 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle6 Lamp LC LD Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Starter7 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Misc. PC HK SS PL LA NL SH 1 2 3 4 5 6 7 400 MH requires reduced jacket ED-28 lamp Distribution depends on tilt angle of fixture Other colors available, please contact your local American Electric Lighting representative T3 option only available with 240, 480, DT2, DT4, MT2 Not available with MT, TT, DT voltages PC and SH not available with NR option For HPS only Photocontrol Included per Voltage Specified6 Hinge Keeper Stainless Steel Fasteners (external) Distribution Pattern Indicator Label Lightning Arrestor NEMA Label Shorting Cap6 Product Guide 37 InterState™ II Series 775 Roadway Lighting — Interstate with Contemporary Style 200-400W HPS, 175-400W MH P R O D U C T O V E R V I E W Features: Unique optical design allows set-back of mounting poles away from traffic areas, while still delivering superior performance Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Slim profile provides a low EPA Door is hinged and easily removable for quick maintenance Anodized aluminum reflector provides uniform lighting distribution with sag or flat glass clear tempered refractor Adjustable and locking knuckle mount provides for precise and secure aiming of the luminaire Suitable for 2-3/8” to 3” O.D. tenons Photocontrol receptacle is adjustable without tools For fast relamping optional tool-less access is available NEMA wattage label, terminal block, and NEMA photocontrol receptacle are standard Applications: All electrical components warranted by American Electric Lighting's 6-year guarantee Interstate roadways Expressways Railway switchyards Shipping docks Large parking lots Suitable for -30°C MH / -40°C HPS Complies with ANSI: C136.2, C136.3, C136.10, C136.15, C136.31 DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS Yoke Mount 775 25S CA MT1 R3 FG 775 25S CA MT1 R3 SG 775 40M SC MT1 R3 SG 775 40S CA MT1 R3 SG Vertical Tenon Mount 19.5" (495) 1" (25) 2" (51) .44" (11) Dia. 1" (25) .78" (20) Dia. Effective Projected Area (EPA) The EPA for the InterState™ II is 2.75 sq. ft. Approx. Wt. = 37 lbs 38 Product Guide 2" (51) For photometric information, visit our website, www.americanelectriclighting.com InterState™ II Series 775 Roadway Lighting — Interstate with Contemporary Style 200-400W HPS, 175-400W MH O R D E R I N G I N F O R M AT I O N Example: 7 7 5 4 0 S C A 4 8 0 R 3 S G Wattage / Source Series 775 InterState Roadway Offset Voltage Distribution 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V 5T4 5-tap Wired 480V3 R3 Roadway Type III4 Ballast RN RH XN 17 20 25 31 40 23 175W S HPS 200W M MH 250W 310W 400W 250/400W Wired 250W1 24 250/400W Wired 400W1 XH Refer to the ballast matrix on page 56 for compatibility. CA CT MR SC Reactor Normal Power Factor Reactor High Power Factor High Reactance (Lag) Normal Power Factor High Reactance (Lag) High Power Factor CWA CWI Mag Reg (3 Coil) SCWA2 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 Optics SG Sag Glass Clear Tempered FG Flat Glass Clear Tempered Options Mounting (blank) Tenon Slipfitter (standard)4 YG Yoke Galvanized YP Yoke Painted5 Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle9 Paint6 (blank) BK BZ WH UP Lamp LC LD Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 and L2 Positions T3 3 Wire Operation (L1, N, L2 Position)7 Standard Listing (blank) UL Listed (standard) CS CSA Certified Fusing8 SF DF Lamp Included, Clear Lamp Included, Deluxe/Coated Starter10 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Misc. PC TL SS PL LA 5H SH Notes: 1 2 3 4 5 6 7 8 9 10 Not available in 5-tap Limited availability, please contact your local American Electric Lighting representative 250W and 400W only Distribution depends on tilt angle of fixture Painted to match specified color of fixture Other colors available, please contact your local American Electric Lighting representative T3 option only available with 240, 480, DT2, DT4, MT2 Not available with MT, TT, DT voltages PC, SH not available with NR option For HPS Products only Photocontrol Included per Voltage Specified9 Tool-less Entry Stainless Steel Fasteners (external) Distribution Pattern Indicator Label Lightning Arrestor 50 Hertz Ballast Cycle2 Shorting Cap9 Single Fuse (120, 277, 347V) Double Fuse (208, 240, 480V) Product Guide 39 LPS Roadway Series SRX Roadway Lighting 35-90W LPS P R O D U C T O V E R V I E W Features: Designed for maximum energy savings with efficient light distribution Vandal resistant, rugged and corrosion resistant die cast aluminum housing Drop polycarbonate prismatic refractor allows for maximum control of light distribution Large surface area "breathing seal," gasket seals the optical chamber to prevent intrusion by insects and environmental contaminants. Heatresistant gasket material remains effective over the life of the fixture. All electrical components warranted by American Electric Lighting's 6-year guarantee Complies with ANSI: C136.2, C136.10 Applications: Roadways Highways Transportation terminals DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS SRX 55L XH DT1 R4 DP LC SRX 55L XH 480 R4 DP NR 4-1/2" (114) 4" (102) 27" (686) 7-1/2" (191) 9" (229) Effective Projected Area (EPA) The EPA for the Roadway Luminaire Series SRX is 1.00 sq. ft. Approx. Wt. = 20 lbs. 40 Product Guide For photometric information, visit our website, www.americanelectriclighting.com LPS Roadway Series SRX Roadway Lighting 35-90W LPS O R D E R I N G I N F O R M AT I O N Example: S R X 0 9 L R H 4 8 0 R 4 D P L C Wattage / Source Series SRX Low Pressure Sodium Roadway 03 35W 55 55W 09 90W L LPS Refer to the ballast matrix on page 57 for compatibility. Voltage Ballast RH Reactor High Power Factor XH High Reactance (Lag) High Power Factor 120 208 240 277 347 480 DT1 120V 208V 240V 277V 347V 480V Dual Tap 120/240 Wired 120V DT2 Dual Tap 120/240 Wired 240V DT5 Dual Tap 208/277 Wired 208V DT6 Dual Tap 208/277 Wired 277V Distribution R4 Roadway Type IV Optics DP Drop Polycarbonate Prismatic Refractor Options Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle1 Lamp LC Lamp Included, Clear Listing UL UL Listed Misc. PC SH Photocontrol Included per Voltage Specified1 Shorting Cap1 Notes: 1 PC and SH not available with NR option Product Guide 41 LPS Roadway Series SP2 Roadway Lighting 90-180W LPS P R O D U C T O V E R V I E W Features: Designed for maximum energy savings with efficient light distribution Outside housing constructed of non-corrosive ABS plastic with UV inhibiting coating Drop acrylic or polycarbonate prismatic refractor allows for maximum control of light distribution All electrical components warranted by American Electric Lighting's 6-year guarantee Applications: Roadways Highways Security lighting Transportation terminals DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS SP2 09L XH DT1 R4 DP LC SP2 13L XH DT1 R4 DP LC SP2 18L XH DT1 R4 DP LC SERIES LENGTH (L) EPA (Sq. Ft.) SP290 397/16'' 1.00 SP213 497/16'' 1.20 SP218 637/16'' 1.45 Approx. Wt. = 31 lbs 42 Product Guide For photometric information, visit our website, www.americanelectriclighting.com LPS Roadway Series SP2 Roadway Lighting 90-180W LPS O R D E R I N G I N F O R M AT I O N Example: S P 2 1 8 L X H 4 8 0 R 4 D P L C Series Wattage / Source 09 90W 13 135W 18 180W SP2 Low Pressure Sodium Roadway L LPS Refer to the ballast matrix on page 57 for compatibility. Voltage Ballast RH Reactor High Power Factor XH High Reactance (Lag) High Power Factor 120 208 240 277 347 480 DT1 120V 208V 240V 277V 347V 480V Dual Tap Wired 120/240 Wired 120V DT2 Dual Tap Wired 120/240 Wired 240V DT5 Dual Tap 208/277 Wired 208V DT6 Dual Tap 208/277 Wired 277V Distribution R4 Roadway Type IV Optics DA Drop Acrylic Prismatic Refractor DP Drop Polycarbonate Prismatic Refractor Options Listing UL CS UL Listed CSA Certified Notes: 1 PC and SH not available with NR option Photocontrol Receptacle (blank) With Photocontrol Receptacle NR No Photocontrol Receptacle1 Lamp LC Lamp Included, Clear Misc. PC SH Photocontrol Included per Voltage 1 Shorting Cap1 Product Guide 43 Underpass Series 581/681 Roadway Lighting 50-250W HPS, 175-250W MH P R O D U C T O V E R V I E W Features: Low profile design for unobtrusive surface mounting Die-cast aluminum back housing with choice of die-cast front housing with borosilicate glass lens, or one-piece polycarbonate front housing and lens Designed for easy access to electrical compartment and optical assembly for installation and maintenance ease All exterior hardware is captive UL and CSA listed for wet locations All electrical components warranted by American Electric Lighting's 6-year guarantee E39 mogul socket standard Suitable for -30°C MH / -40°C HPS Applications: Office complexes Shopping centers and malls Schools and hospitals Parking garages Tunnel and underpasses Parks DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 581 15S CA 120 581 15M XN MT1 681 10S RN 120 681 15S RN 120 681 15M XN MT1 Approx. Wt. = 30 lbs 44 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Underpass Series 581/681 Roadway Lighting 50-250W HPS, 175-250W MH O R D E R I N G I N F O R M AT I O N Example: 5 8 1 2 5 S C A M T 1 G Y Wattage / Source Series 581 Wallpack w/ Die-cast and Glass Front housing 681 Wallpack w/ Polycarbonate Front Housing1 S HPS 05 50 W M MH 07 70 W 10 100 W 15 150 W 17 175 W 20 200 W 25 250 W Refer to the ballast matrix on page 57 for compatibility. Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA CT CWI 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 DT4 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V Dual Tap 240/480 Wired 480V Options Mounting (blank) Wall Mount (standard) Paint2 (blank) BK WH GY UP Bronze (standard) Black White Gray Unpainted Listing (blank) CS UL Listing (standard) CSA Certified Fusing3 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 240, 480V) Photocontrol Receptacle (blank) Button Control (standard) (multi-volt options not available) NC No Photocontrol Notes: 1 2 3 4 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Misc. SE SS 5H NL Side Entry Stainless Steel Fasteners (external) 50 Hertz Ballast Cycle4 NEMA Label Max Wattage 175W, only available in bronze Other colors available, please contact your local American Electric Lighting representative Not available with MT, TT, DT voltages Limited availability, please contact your local American Electric Lighting representative Product Guide 45 Heavy Duty Wallpack Series 882 Roadway Lighting — Building Mounted 200-400W HPS, 175-400W MH P R O D U C T O V E R V I E W Features: Designed for easy access to electrical compartment and optical assembly for installation and maintenance ease Heavy duty, two piece, die cast aluminum housing with hinged, captive bezel and corrosion resistant hardware Completely sealed with high temperature silicone gasket High impact and heat resistant borosilicate glass refractor One piece, stippled, asymmetric anodized aluminum reflector designed to produce a wide pattern of efficient illumination UL and CSA certified for wet locations All electrical components warranted by American Electric Lighting's 6-year guarantee Suitable for -30°C MH / -40°C HPS Applications: Parking areas Perimeter lighting Entrances and walkways Waterfront areas Loading platforms Recreational areas DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 882 25S CA MT7 882 40M CA 5T4 Approx. Wt. = 36 lbs 46 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Heavy Duty Wallpack Series 882 Roadway Lighting — Building Mounted 200-400W HPS, 175-400W MH O R D E R I N G I N F O R M AT I O N Example: 8 8 2 2 5 S C A M T 1 Wattage / Source Series 882 Wallpack 17 20 25 31 40 175W 200W 250W 310W 400W S HPS M MH Voltage Ballast CA CWA CT CWI MR Mag Reg 480 MT1 MT2 MT7 MT8 5T4 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Multi tap Wired 208V 5-tap Wired 480V Refer to the ballast matrix on page 58 for compatibility. Options Listing (blank) CS UL Listed (standard) CSA Certified Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Product Guide 47 SignLite Series 875 Roadway Lighting — Sign Light 175-400W MH, 200-400W HPS P R O D U C T O V E R V I E W Features: Die cast low copper aluminum housing offers light weight and corrosion resistance with excellent durability Hinged door is easily removable for quick maintenance, tool-less option makes relamping easy Anodized aluminum reflector provides uniform lighting distribution with sag or flat clear tempered glass lens Rotatable optics UL listed for wet locations All electrical components warranted by American Electric Lighting's 6-year guarantee Suitable for -30°C MH / -40°C HPS Complies with ANSI: C136.2, C136.10, C136.15 Applications: Interstate highways Outdoor advertising signs Traffic flow signs Building facades Security lighting Corporate and building lighting Other vertical surfaces, watts DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS Yoke Mount 875 25M SC 120 56 SG Vertical Tenon Mount 19.5" (495) 1" (25) 2" (51) .44" (11) Dia. 1" (25) .78" (20) Dia. 2" (51) Effective Projected Area (EPA) The EPA for the Signlite Luminaire, Series 875 is 2.75 sq. ft. Approx. Wt. = 37 lbs 48 Product Guide For photometric information, visit our website, www.americanelectriclighting.com SignLite Series 875 Roadway Lighting — Sign Light 175-400W MH, 200-400W HPS O R D E R I N G I N F O R M AT I O N Example: 8 7 5 4 0 M C A 4 8 0 6 6 S G Wattage / Source Series 875 Sign Light 17 20 25 31 40 23 175W 200W 250W 310W 400W 250/400W Wired 250W1 24 250/400W Wired 400W1 Voltage Ballast S HPS M MH Refer to the ballast matrix on page 58 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Auto Reg CT CWI MR Mag Reg (3 Coil) SC SCWA 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 DT4 5T4 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V Dual Tap 240/480 Wired 480V 5-tap Wired 480V2 Distribution3 56 5H X 6V NEMA distribution 66 6H X 6V NEMA distribution Optics SG Sag Glass Clear Tempered FG Flat Glass Clear Tempered Options Mounting (blank) Tenon Mount (standard)4 YG Yoke Galvanized YP Yoke Painted3 Paint5 (blank) BK BZ WH UP Gray (standard) Black Bronze White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 and L2 Position T3 3 Wire Operation (L1, N, L2 Position)6 Listing (blank) CS Fusing7 SF DF UL Listed (standard) CSA Certified Single Fuse (120, 277, 347V) Double Fuse (208, 240, 480V) Photocontrol Receptacle (blank) Photocontrol Receptacle (standard) NR No Photocontrol Receptacle8 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Starter9 EC Encapsulated Plug-in OP Open Plug-in Misc. TL BT SS CF LA PC 5H NL SH Tool-less Entry Ballast Tray Stainless Steel Fasteners (external) Charcoal Filter Lightning Arrestor (Void UL/CSA Listed Options) Photocontrol Included per Voltage Specified8 50 Hertz Ballast Cycle10 NEMA Label Shorting Cap8 Notes: 1 2 3 4 5 6 7 8 9 10 Not available in 5-tap 250W and 400W only Distribution depends on tilt angle of fixture Painted to match specified color of fixture Other colors available, please contact your local American Electric Lighting representative T3 option only available with 240, 480, DT2, DT4, MT2 Not available with MT, TT, DT voltages PC, and SH not available with NR option Available in HPS only Limited availability, please contact your local American Electric Lighting representative Product Guide 49 Accessories AVA I L A B I L I T Y 115 Glare Shield House Side Shield, Cutoff House Side Shield, Drop Polycarbonate Vandal Shield1 Ballistic Shield for Flat Lens Ballistic Shield for Flat Lens with Side Protection Ballistic Shield for Drop Lens Wireguard1 RK115 GS 315 - RK125-GS 125 115 HS SHLD EXTERNAL FG/SG 315 HS SHLD EXTERNAL FG/SG 125 HS SHLD EXTERNAL FG/SG 115 HS SHLD EXTERNAL DG 315 HS SHLD EXTERNAL DG 125 HS SHLD EXTERNAL DG 325 -325 HS SHLD EXTERNAL DG 581/681 - 882 - - - - RK581 VS 115 PGS FL 25W2 315 PGS FL 25W2 125 PGS FL 40W3 325 PGS FL 40W3 115 PGS FL 25W SPS2 315 PGS FL 25W SPS2 - - 115 PGS DL 25W2 315 PGS DL 25W2 125 PGS DL 40W3 325 PGS DL 40W3 - - - - - - RK581/681 WG RK882 WG 325 HS SHLD EXTERNAL FG/SG NOTES: 1 Polycarbonate Vandal shield and Wireguard can not be used simultaneously 2 250W lamp maximum 3 400W lamp maximum 50 Product Guide Description Catalog Number SERIES 115 GLARE SHIELD RK115 GS HOUSE SIDE SHIELD FOR FLAT/SAG GLASS HOUSE SIDE SHIELD FOR DROP GLASS HOUSE SIDE SHIELD FOR FLAT/SAG GLASS HOUSE SIDE SHIELD FOR DROP GLASS HOUSE SIDE SHIELD FOR FLAT/SAG GLASS HOUSE SIDE SHIELD FOR DROP GLASS HOUSE SIDE SHIELD FOR FLAT/SAG GLASS HOUSE SIDE SHIELD FOR DROP GLASS 115 HS SHLD EXTERNAL FG/SG 115 HS SHLD EXTERNAL DG 315 HS SHLD EXTERNAL FG/SG 315 HS SHLD EXTERNAL DG 125 HS SHLD EXTERNAL FG/SG 125 HS SHLD EXTERNAL DG 325 HS SHLD EXTERNAL FG/SG 325 HS SHLD EXTERNAL DG POLYCARBONATE SHIELD FOR SIDELITE 581 RK581 VS For photometric information, visit our website, www.americanelectriclighting.com Accessories S H I E L D S Description BALLISTIC SHIELDS / W I R E G U A R D S Catalog Number RK115 or 315 PGS FL 25W RK115 or 315 PGS FL 25W SPS RK115 or 315 PGS DL 25W RK115 or 315 PGS DL 25W SPS RK125 or 325 PGS FL 40W RK125 or 325 PGS DL 40W 6.25" (159) 8.67" (220) WIRE GUARDS RK581/681 WG RK882 WG 6.50" (194) 17" (432) 16.63" (422) 6.50" (165) Product Guide 51 Roadway Lighting B A L L A S T M AT R I C E S Corvus CVM Watts 07S 10S 15S 13S 14S 17M 20S 25S 25M 40S 120 CA,CT,MR,RH,RN CA,CT,MR,RH,RN CA,CT,MR,RH,RN RN,RH RN,RH CA CA,CT,XN,XH CA,CT,XN,XH CA,CT - 208 XH,CA,XN CA,CT,XN,XH CA,CT,XN,XH CA CA,CT CA,CT CA RN,RH 240 CA,MR,XH,XN CA,CT,MR,XH,XN CA,CT,MR,XH,XN CA CA,XN,XH CA,CT,XN,XH CA,CT RN,RH 277 XH,CA,CT,XN CA,XH,XN XN,XH,CA,CT CA CA,CT CA,CT CA,CT - 347 XH,XN CT,XH,XN CA, CT,XH,XN CA CA CA,CT 480 DT2 XH,XN CA,CT,MR,XH,XN CA,CT,XN CA,CT,MR,XH,XN CA,MR,XN,XH CA,CT,MR,XH,XN CA CA CA,CT CA,CT,XN,XH CA CA,CT,XN,XH CA,CT CA,CT - DT4 MR MR CT - Corvus CVM continued Watts 07S 10S 15S 13S 14S 17M 20S 25S 25M 40S MT1 CA,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA,CT CA,CT CA - MT2 CA,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA,CT CA,CT CA - MT7 CA,XH,XN CA,CT,XN,XH CA,CT,XH,XN CA CA,CT CA,CT CA - TT3 CT,XH,XN CT,XH,XN XH,XN CA CA,CT CA,CT - Corvus CVL Watts 17M 20S 25S 25M 31S 40S 40M 23/24S 23/24M 120 CA CA,CT,MR,XN,XH CA,CT,MR,XN,XH CA,CT,SC CA,MR CA,CT,MR,XN,XH CA,CT,SC CA,CT, CA 208 CA CA, CT CA,CT,MR CA,SC CA CA,CT,MR,RN,RH CA,CT,SC CA,CT, CA 240 CA CA,CT,RN,RH,MR CA,CT,RN,RH,MR CA,CT,SC CA,MR CA,CT,MR,RN,RH, CA,CT,SC CA,CT CA 277 CA CA,CT CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA 347 CA CA CA,CT,SC CA CA,CT,SC - 480 CA CA,CT,MR CA,MR CA,CT CA,MR CA,MR CA CA CA DT2 CA CA,CT,MR,XN,XH XN,XH,MR CA,CT,SC CA,MR CA,CT,MR,XN,XH CA,CT CA,CT CA Corvus CVL continued Watts 17M 20S 25S 25M 31S 40S 40M 23/24S 23/24M MT1 CA CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA MT2 CA CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA MT7 CA CT,CA CA,CT CA,SC CA CA,CT CA,SC CA,CT CA TT3 CA CA,CT CA,CT,SC CA CA,CT,SC - 5T4 CA CA CA CA - DuraStar Series 20 Watts 05S 07S 10S 15S 17M 120 RH,RN CA,CT,RN,RH,XN,XH CA,CT,RN,RH,XN,XH CA,CT,RN,RH,XN,XH CA,CT 208 CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA,CT, 240 CA,CT,XH,XN CA,CT,XH,XN CA,CT,RN,RH,XN,XH CA,CT 277 XN CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA,CT 480 XH,XN CA,XN,XH CA,CT CA,CT DT2 CA CA,CT,XH CA,CT,XH,XN CA,CT DuraStar Series 20 continued Watts 05S 07S 10S 15S 17M 52 MT1 XN,XH CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN Product Guide MT2 XN,XH CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN MT7 XN,XH CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN TT3 XN,XH XN,XH XN,XH CA For photometric information, visit our website, www.americanelectriclighting.com DT4 CA - DT4 MR MR MR CT - Roadway Lighting B A L L A S T M AT R I C E S DuraStar Series 30 Watts 17M 20S 25S 25M 31S 40S 40M 23/24S 23/24M 120 CA CA,CT,MR,XH,XN CA,CT,MR,XH,XN CA,CT,SC CA,MR CA,CT,MR,XH,XN CA,CT,SC CA CA 208 CA,CT CA,CT CA,CT CA,SC CA,MR CA,CT,RH,RN CA,SC CA CA 240 CA CA,CT,MR,XH,XN CA,CT,MR,XH,XN CA,CT,SC CA,MR CA,CT,MR,XH,XN,RH,RN CA,CT,SC CA CA 277 CA CA,CT CA,CT CA,SC MR,CA CA,CT SC,CA,CT CA CA 347 CA CA CA CA,CT,SC - 480 CA CA,CT CA,MR CA,SC CA,MR CA,MR CA,CT - DT2 CA,CT CA,CT,MR,XH,XN CA,CT,MR,XH,XN CA CA,MR MR CA,CT,SC CA CA 5T4 CA CA CA CA - DuraStar Series 30 continued Watts 17M 20S 25S 25M 31S 40S 40M 23/24S 23/24M DT4 MR MR - MT1 CA CA,CT CA,CT CA,SC CA CA,CT SC,CA CA CA MT2 CA CA,CT CA,CT CA,SC CA CA,CT SC,CA CA CA MT7 CA CA,CT CA,CT CA,SC CA CA,CT CA,SC CA TT3 CA CA CA CA - Roadway 115 Watts 03S 05S 07S 10S 15S 13S 14S 17M 20S 25S 25M 40S 120 RN RH,RN CA,CT,MR,RH,RN CA,CT,MR,RH,RN CA,CT,MR,RH,RN RN,RH RN,RH CA CA,CT,XN,XH CA,CT,XN,XH CA,CT - 208 XH,CA,XN CA,CT,XN,XH CA,CT,XN,XH CA CA,CT CA,CT CA RN,RH 240 CA,MR,XH,XN CA,CT,MR,XH,XN CA,CT,MR,XH,XN CA CA,XN,XH CA,CT,XN,XH CA,CT RN,RH 277 XN XH,CA,CT,XN CA,XH,XN XN,XH,CA,CT CA CA,CT CA,CT CA,CT - 347 XH,XN CT,XH,XN CA, CT,XH,XN CA CA CA,CT 480 DT2 XH,XN CA,CT,MR,XH,XN CA,CT,XN CA,CT,MR,XH,XN CA,MR,XN,XH CA,CT,MR,XH,XN CA CA CA,CT CA,CT,XN,XH CA CA,CT,XN,XH CA,CT CA,CT - DT4 MR MR CT - Roadway 115 continued Watts 03S 05S 07S 10S 15S 13S 14S 17M 20S 25S 25M 40S MT1 CA,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA,CT CA,CT CA - MT2 CA,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA,CT CA,CT CA - MT7 CA,XH,XN CA,CT,XN,XH CA,CT,XH,XN CA CA,CT CA,CT CA - TT3 CT,XH,XN CT,XH,XN XH,XN CA CA,CT CA,CT - Product Guide 53 Roadway Lighting B A L L A S T M AT R I C E S Roadway 315 Watts 03S 05S 07S 10S 15S 13S 14S 17M 20S 25S 25M 40S 120 RN RH,RN CA,CT,MR,RH,RN CA,CT,MR,RH,RN CA,CT,MR,RH,RN RN,RH RN,RH CA CA,CT,XH,XN CA,CT,XH,XN CA,CT,SC CA,XH,XN 208 CA,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA,CT CA,CT CA,SC CA 240 CA,MR,XH,XN CA,CT,MR,XH,XN CA,CT,MR,XH,XN CA CA,CT,RH,RN,XH,XN CA,CT,RH,RN CA,CT,SC CA,RH,RN 277 XN XH,CA,CT,XN CA,CT,XH,XN XH,CA,XN CA CA,CT CA,CT CA,CT,SC - 480 XH,XN CA,CT,MR,XH,XN CA,CT,MR,XH,XN CA CA,CT CA CA,CT,SC CA DT2 XH,XN CA,CT,MR,XH,XN CA,CT,MR,XH,XN CA,CT,MR,XH,XN CA CA,CT,XH,XN CA,CT,XH,XN CA,CT,SC - Roadway 315 continued Watts 03S 05S 07S 10S 15S 13S 14S 17M 20S 25S 25M 40S DT4 MR - MT1 XH,XN,CA CA,CT,XN,XH CA,CT,XN,XH CA CA,CT CA,CT,SC CA,SC CA,XN,XH MT2 CA, XN,XH CA,CT,XN,XH CA,CT,XN,XH CA CA,CT CA,CT,SC CA,SC CA,XN,XH MT7 CA, XN,XH CA,CT,XN,XH CA,CT,XN,XH CA CA,CT CA,CT,SC CA,SC CA,XN,XH TT3 CT,XN,XH CT,XN,XH XN,XH CA CA,CT CA,CT,SC - 347 XN,XH CT,XN,XH XN,XH CA CA CA,CT,SC - Roadway 125 Watts 17M 20S 25S 25M 31S 40S 40M 23/24S 23/24M 120 CA CA,CT,MR,XN,XH CA,CT,MR,XN,XH CA,CT,SC CA,MR CA,CT,MR,XN,XH CA,CT,SC CA,CT, CA 208 CA CA, CT CA,CT,MR CA,SC CA CA,CT,MR,RN,RH CA,CT,SC CA,CT, CA 240 CA CA,CT,RN,RH,MR CA,CT,RN,RH,MR CA,CT,SC CA,MR CA,CT,MR,RN,RH, CA,CT,SC CA,CT CA 277 CA CA,CT CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA 347 CA CA CA,CT,SC CA CA,CT,SC - 480 CA CA,CT,MR CA,MR CA,CT CA,MR CA,MR CA CA CA DT2 CA CA,CT,MR,XN,XH XN,XH,MR CA,CT,SC CA,MR CA,CT,MR,XN,XH CA,CT CA,CT CA Roadway 125 continued Watts 17M 20S 25S 25M 31S 40S 40M 23/24S 23/24M 54 MT1 CA CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA Product Guide MT2 CA CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA MT7 CA CT,CA CA,CT CA,SC CA CA,CT CA,SC CA,CT CA TT3 CA CA,CT CA,CT,SC CA CA,CT,SC - 5T4 CA CA CA CA - For photometric information, visit our website, www.americanelectriclighting.com DT4 MR MR MR CT - Roadway Lighting B A L L A S T M AT R I C E S Roadway 325 Watts 17M 20S 25S 25M 31S 40S 40M 23/24S 23/24M 120 CA CA,CT,MR,XH,XN CA,CT,MR,XH,XN CA,CT,SC CA,MR CA,CT,MR,XH,XN CA,CT,SC CA,CT, CA 208 CA CA, CT CA,CT,MR CA,SC CA CA,CT,MR,RN,RH CA,CT,SC CA,CT, CA 240 CA CA,CT,MR,RN,RH CA,CT,MR,RN,RH CA,CT,SC CA,MR CA,CT,MR,RN,RH CA,CT,SC CA,CT CA 277 CA CA,CT CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA 347 CA CA CA,CT,SC CA CA,CT,SC - 480 CA CA,CT,MR CA,MR CA,CT CA,MR CA,MR CA CA CA DT2 CA CA,CT,MR,XH,XN XN,XH,MR CA,CT,SC CA,MR CA,CT,MR,XH,XN CA,CT CA,CT CA MT2 CA CA MT7 CA CA DT4 MR MR MR CT - Roadway 325 continued Watts 17M 20S 25S 25M 31S 40S 40M 23/24S 23/24M MT1 CA CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA MT2 CA CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA MT7 CA CT,CA CA,CT CA,SC CA CA,CT CA,SC CA,CT CA TT3 CA CA,CT CA,CT,SC CA CA,CT,SC - 5T4 CA CA CA CA - Roadway 327 Watts X1S X1M 120 CA,CT CA 208 CA,CT CS 240 CA,CT CA,SC 277 CA,CT CA 480 CA,CT CA MT1 CA CA 5T4 CA XA Product Guide 55 Roadway Lighting B A L L A S T M AT R I C E S Multi-Mount 285 Watts 20S 25S 25M 31S 40S 40M 23/24S 23/24M 120 CA,CT,MR,XN,XH CA,CT,MR,XN,XH CA,CT,SC CA,MR CA,CT,MR,XN,XH CA,CT,SC CA,CT, CA 208 CA, CT CA,CT,MR CA,SC CA CA,CT,MR,RN,RH CA,CT,SC CA,CT, CA 240 CA,CT,MR,RN,RH CA,CT,MR,RN,RH CA,CT,SC CA,MR CA,CT,MR,RN,RH CA,CT,SC CA,CT CA 277 CA,CT CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA 480 CA,CT,MR CA,MR CA,CT CA,MR CA,MR CA CA CA DT2 CA,CT,MR,XN,XH XN,XH,MR CA,CT,SC CA,MR CA,CT,MR,XN,XH CA,CT CA,CT CA DT4 MR MR MR CT - DT2 CA CA,CT,MR,XN,XH XN,XH,MR CA,CT,SC CA,MR CA,CT,MR,XN,XH CA,CT CA,CT CA DT4 MR MR MR CT - Multi-Mount 285 continued Watts 20S 25S 25M 31S 40S 40M 23/24S 23/24M MT1 CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA MT2 CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA MT7 CT,CA CA,CT CA,SC CA CA,CT CA,SC CA,CT CA TT3 CA,CT CA,CT,SC CA CA,CT,SC - 347 CA CA,CT,SC CA CA,CT,SC - 5T1 CA CA CA CA - Interstate II 775 Watts 17M 20S 25S 25M 31S 40S 40M 23/24S 23/24M 120 CA CA,CT,MR,XN,XH CA,CT,MR,XN,XH CA,CT,SC CA,MR CA,CT,MR,XN,XH CA,CT,SC CA,CT, CA 208 CA CA, CT CA,CT,MR CA,SC CA CA,CT,MR,RN,RH CA,CT,SC CA,CT, CA 240 CA CA,CT,MR,RN,RH CA,CT,MR,RN,RH CA,CT,SC CA,MR CA,CT,MR,RN,RH CA,CT,SC CA,CT CA 277 CA CA,CT CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA 480 CA CA,CT,MR CA,MR CA,CT CA,MR CA,MR CA CA CA Interstate II 775 continued Watts 17M 20S 25S 25M 31S 40S 40M 23/24S 23/24M 56 MT1 CA CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA Product Guide MT2 CA CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA MT7 CA CT,CA CA,CT CA,SC CA CA,CT CA,SC CA,CT CA TT3 CA CA,CT CA,CT,SC CA CA,CT,SC - 347 CA CA CA,CT,SC CA CA,CT,SC - 5T1 CA CA CA CA - For photometric information, visit our website, www.americanelectriclighting.com Roadway Lighting B A L L A S T M AT R I C E S LPS Roadway SRX Watts 03L 55L 09L 120 XH XH XH 208 XH XH XH 240 XH XH XH 277 XH XH XH 347 XH XH XH 480 RH RH RH 240 XH XH XH 277 XH XH XH 347 XH XH XH 480 XH RH,XH XH DT1 XH XH XH DT2 XH XH XH DT5 XH XH XH DT6 XH XH XH LPS Roadway SP2 Watts 09L 13L 18L 120 XH XH XH 208 XH XH XH DT1 XH XH XH DT2 XH XH XH DT5 XH XH XH DT6 XH XH XH UnderPass Series 581/681 Watts 05S 07S 10S 15S 17M 20S 25S 25M 120 RN CA,CT,MR,RN RH CA,CT,RN,RH CA,MR,RN,RH CA XN,XH XN,XH CA 208 CA,CT,XN,XH CA,CT,XN,XH CA,XN,XH CA CA 240 CA,CT,MR,XN,XH CA,CT,XN,XH CA,MR,XN,XH CA XN,XH XN,XH CA 277 CA,XN,XH CA,CT,XN,XH CA,XN,XH CA CA 480 CA CA CA,MR CA - DT2 CA,CT,MR,XN,XH CA,CT CA,MR CA XN,XH XN,XH CA UnderPass Series 581/681 continued Watts 05S 07S 10S 15S 17M 20S 25S 25M DT4 MR MR - MT1 CA CA,CT CA CA CA MT2 CA CA,CT CA CA CA MT7 CA CA,CT CA CA CA MT8 CA CA,CT CA CA CA TT1 XN,XH XN,XH XN,XH CA - TT3 XN,XH XN,XH XN,XH CA - TT7 XN,XH XN,XH XN,XH CA - 347 XN,XH CT,XN,XH XN,XH CA - Product Guide 57 Roadway Lighting B A L L A S T M AT R I C E S Heavy Duty Wallpack 882 Watts 17M 20S 25S 25M 31S 40S 40M 120 CA CA,CT,MR,XN,XH CA,CT,MR,XN,XH CA,CT,SC CA,MR CA,CT,MR,XN,XH CA,CT,SC 208 CA CA, CT CA,CT,MR CA,SC CA CA,CT,MR,RN,RH CA,CT,SC 240 CA CA,CT,MR,RN,RH CA,CT,MR,RN,RH CA,CT,SC CA,MR CA,CT,MR,RN,RH CA,CT,SC 277 CA CA,CT CA,CT,MR CA,SC CA CA,CT,MR CA,SC 480 CA CA,CT,MR CA,MR CA,CT CA,MR CA,MR CA DT2 CA CA,CT,MR,XN,XH MR,XN,XH CA,CT,SC CA,MR CA,CT,MR,XN,XH CA,CT DT4 MR MR MR CT DT2 CA CA,CT,MR,XN,XH XN,XH,MR CA,CT,SC CA,MR CA,CT,MR,XN,XH CA,CT CA,CT CA DT4 MR MR MR CT - Heavy Duty Wallpack 882 continued Watts 17M 20S 25S 25M 31S 40S 40M MT1 CA CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC MT2 CA CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC MT7 CA CT,CA CA,CT CA,SC CA CA,CT CA,SC TT3 CA CA,CT CA,CT,SC CA CA,CT,SC 347 CA CA,CT CA,CT,SC CA CA,CT,SC 5T4 CA CA CA CA SignLite 875 Watts 17M 20S 25S 25M 31S 40S 40M 23/24S 23/24M 120 CA CA, CT, XN, XH MR XH,XN,CA,CT,MR CA,CT,SC CA,MR CA,CT,XN,XH,MR CA,CT,SC CA,CT, CA 208 CA CA, CT CA,CT,MR CA,SC CA CA,CT,MR,RN,RH CA,CT,SC CA,CT, CA 240 CA CA,CT,RN,RH,MR CA,CT,RN,RH,MR CA,CT,SC CA,MR CA,CT,RN,RH,MR CA,CT,SC CA,CT CA 277 CA CA,CT CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA 480 CA CA,CT,MR CA,MR CA,CT CA,MR CA,MR CA CA CA SignLite 875 continued Watts 17M 20S 25S 25M 31S 40S 40M 23/24S 23/24M 58 MT1 CA CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA Product Guide MT2 CA CT,CA CA,CT,MR CA,SC CA CA,CT,MR CA,SC CA,CT CA MT7 CA CT,CA CA,CT CA,SC CA CA,CT CA,SC CA,CT CA TT3 CA CA,CT CA,CT,SC CA CA,CT,SC - 347 CA CA CA,CT,SC CA CA,CT,SC - 5T4 CA CA CA CA - For photometric information, visit our website, www.americanelectriclighting.com DECORATIVE AND POST TOP LIGHTING Valiant ........................................................................60 Decorative Poles ......................................................90 American Revolution Deluxe Series ....................62 Chadsworth Series................................................90 American Revolution Series 247............................64 New Albany Series ...............................................92 Georgian Series GRP ...............................................66 Statesboro Series..................................................94 Bainbridge Series 870 .............................................68 Waycross Series ...................................................96 Marietta Series.........................................................70 Weatherproof Receptacles .................................98 Sumter Series ...........................................................72 Ballast Matrices .....................................................100 Cresthill Classic ........................................................74 Cresthill Sphere ........................................................76 Cresthill Centennial..................................................78 Cresthill Glass ...........................................................80 Lexington ...................................................................82 Branson......................................................................84 Contempo Series 245 ..............................................86 TwistPack Series TWT ............................................88 American Electric Lighting® 59 Valiant TM Series AVP 50-250W HPS, 70-250W MH P R O D U C T O V E R V I E W Features: NEW Die-cast aluminum housing and hood for long-life performance Optical assembly designed for maximum performance Hinged hood and captive screw provision afford quick, easy access to electrical and optical area for relamping or servicing. Trigger latch (TL) optional Slipfitter with three set screws allows secure installation to pole sizes 2-3/8" or 3" O.D. E39 mogul base socket standard Tool-less cupola for easy photocontrol adjustment Tooled cupola lens to prevent wildlife entry into luminaire All electrical components warranted by American Electric Lighting's 6-year guarantee Complies with ANSI: C136.2, C136.10, C136.15, C136.3.1 Suitable for -30°C MH / -40°C HPS 40°C Rated Applications: Encapsulated plug-in starter, standard Streetscapes Walkways Pathways Parks Stainless steel fasteners (external), standard Terminal block, standard DIMENSIONS FULL CUTOFF PREFERRED SELECTION CATALOG NUMBERS VIEUX OPTION AVP 13S RH 120 R3 FC NL TL AVP 10S CA MT1 R3 AY LC PC LDR PA30 AVP 10S CA MT1 R5 AY VX LC PC LDR PA30 AVP 10S RN 120 R3 AY TL AVP 10S RN 120 R5 AY TL AVP 13S RH 120 R3 AY NL HS TL Effective Projected Area (EPA) The EPA for the Valiant 2.4 sq. ft. The EPA for the Valiant Vieux is 2.4 sq. ft. The EPA for the Valiant Full Cutoff is 1.5 sq. ft. Approx. Wt. = 36 lbs. 60 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Valiant TM Series AVP 50-250W HPS, 70-250W MH O R D E R I N G I N F O R M AT I O N Example: A V P 1 7 M C A M T 1 R 3 A Y L C P C L D R P A 3 0 Series AVP Valiant Post Top 05 07 10 13 15 17 20 25 Wattage / Source Ballast S HPS 50W M MH 70W 100W 100/150W 150W 175W 200W1 250W CA CWA Autotransformer CT CWI Autotransformer SC SCWA2 RH Reactor High Power Factor RN Reactor Normal Power Factor XH High Reactance/Lag High Power Factor XN High Reactance/Lag Normal Power Factor Voltage Refer to ballast matrix on page 100 for compatibility. 120 208 240 277 347 480 DT1 DT2 MT1 MT2 MT7 MT8 TT3 Distribution Optics AY Acrylic R2 Type II 120V PY Polycarbonate3 R3 Type III 208V FC Full Cutoff8 R5 Type V 240V 277V Refer to optical matrix 347V below for compatibility 480V Dual Tap 120/240 wired 120 Dual Tap 120/240 wired 240 Multi-tap Wired 120 Multi-tap Wired 240 Multi-tap Wired 277 Multi-tap Wired 208 Tri-tap Wired 347 Options Post Top Design VX Valiant Vieux4 Paint (blank) GY WH Fusing SF DF Black Textured (standard) Gray White Single Fuse (120, 277, 347V) Double Fuse (208, 240, 480) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR PECR with Shorting Cap Installed Lamp LC Listing UL CS Misc. PC NL HS SH TL HP LDR PA30 PB30 PC30 Lamp Included, Clear Notes: UL Listed CSA Certified 1 2 3 4 5 6 7 8 Photocontrol Included per Voltage Specified5 NEMA Label Attached Houseside Shield4 Shorting Cap5 Tool-less Trigger Latch Entry High Performance Optics6 Ladder Rest7 Terminal Block Pre-wired 30’ # 10 CU Solid B/W/G Terminal Block Pre-wired 30’ # 10 CU Solid B/B/G Terminal Block Pre-wired 30’ # 10 CU Solid B/B/W/G Available in HPS only Contact factory for availability PY available in 175W max Full cutoff not available Not available with NR option Not available with VX or FC options Ships with unit, field installed Nighttime FriendlyTM optic Optic Distribution 05S 07S 10S 15S 20S 25S 17M 25M R2 AY N N N N N N N N R3 AY N N N N N N N N R5 AY N N N N N N N N R3 AY VX R5 AY VX N N N N N N N N N N N N N N N N R3 FC N N N N N N R2 AY HP R5 AY HP N N N N N N N N N N N N N N N N Product Guide 61 American Revolution Deluxe Series ARD and ARD Cutoff 50-150W HPS, 70-175W MH P R O D U C T O V E R V I E W Features: NEW Die-cast aluminum housing and hood for long-life performance Die-cast trigger latch (TL) option available for easy access to internal components Optical assembly designed for maximum performance Hinged hood and captive screw provision afford quick, easy access to electrical and optical area for relamping or servicing Slipfitter with three set screws allows secure installation to pole sizes 2-3/8" or 3" O.D. E39 Mogul base socket standard Meets IESNA Full Cutoff classification All electrical components warranted by American Electric Lighting's 6-year guarantee Suitable for -30ºC MH / -40ºC HPS Tool-less cupola for easy photocontrol adjustment Applications: Tooled cupola lens to prevent wildlife entry into luminaire Complies with ANSI: C136.2, C136.10, C136.15, C136.3.1 Streetscapes Walkways Pathways Parks 40°C Rated Stainless steel fasteners (external), standard Terminal block, standard Full cutoff version is “Nighttime FriendlyTM” DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS ARD 10S RN 120 R3 AY EC TL ARD 10S RN 120 R5 AY EC TL ARD 10M XN MT1 R3 AY TL ARD 10S CA MT1 R2 FC EC TL Effective Projected Area (EPA) The EPA for the American Revolution Series 247 is 1.6 sq. ft. Approx. Wt. = 36 lbs. 62 Product Guide For photometric information, visit our website, www.americanelectriclighting.com American Revolution Deluxe Series ARD and ARD Cutoff 50-150W HPS, 70-175W MH O R D E R I N G I N F O R M AT I O N Example: A R D 1 5 S R N 1 2 0 R 5 A Y E C Wattage / Source Series ARD American Revolution Deluxe Post Top 05 07 10 15 17 50W 70W 100W 150W 175W S HPS M MH Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Autotransformer 120 208 240 277 480 MT1 MT8 MT2 MT7 120V 208V 240V 277V 480V Multi-tap wired 120V Multi-tap wired 208V Multi-tap wired 240V Multi-tap wired 277V Distribution R2 R3 R5 RV Type II Type III11 Type V2,11 Type V3.11 Optics AY Acrylic* PY Polycarbonate* FC Full Cutoff12 Refer to ballast matrix on page 100 for compatibility. *Refer to optical matrix below for compatibility Options Paint4 (blank) GY WH BZ Black (standard) Gray White Bronze Lamp LC LD Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Starter6 (blank) Open Board (standard) EC Encapsulated Plug-in11 OP Open Plug-in11 Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Position T3 3 Wire Operation (L1, N, L2 Position)11 Misc. PC Listing11 UL UL Listed SH SS CS CSA Certified 5H NL Fusing10 HS SF Single Fuse (120, 277, 347V) TL DF Double Fuse (208, 240, 480V) LDR Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle5 1 2 3 4 5 6 7 Photocontrol Included per Voltage Specified5 Shorting Cap5 Stainless Steel Hardware 50 Hertz Ballast Cycle7 NEMA Label (2x2) House Side Shield9 Tool-less Entry Ladder Rest13 8 9 10 11 12 13 Voids UL/CSA Listing Four white panels Four clear panels Other colors available, please contact your local American Electric Lighting representative PC, SH not available with NR option HPS only Limited availability, please contact your local American Electric Lighting representative T3 option only available with 240, 480, DT2, DT4, MT2 Acrylic only Not available in MT voltage Not available on FC version Nighttime FriendlyTM optic Ships with unit, field installed Optic Distribution 05S 07S 10S 15S 07M 10M 15M 17M R2 AY R3 AY R5 AY RV AY R2 PY N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N R3 PY R5 PY RV PY R2 FC N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N Product Guide 63 American Revolution Series 247 and 247 Cutoff 50-150W HPS, 70-175W MH P R O D U C T O V E R V I E W Features: SERIES 247 Die-cast aluminum housing and hood for long-life performance Die-cast trigger latch (TL) option available for easy access to internal components Optical assembly designed for maximum performance Hinged hood and captive screw provision afford quick, easy access to electrical and optical area for relamping or servicing Slipfitter with three set screws allows secure installation to pole sizes 2-3/8" or 3" O.D. E39 mogul base socket standard All electrical components warranted by American Electric Lighting's 6-year guarantee Complies with ANSI: C136.2, C136.10, C136.15, C136.31 (regular only), C136.16 (FC only) Suitable for -30°C MH & / -40°C HPS Full cutoff version is “Nighttime FriendlyTM” SERIES 247 CUTOFF Applications: Streetscapes Walkways Pathways Parks DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS Series 247 247 10S RN 120 R3 AY 247 15S RN 120 R3 AY 247 10S RN 120 R5 AY 247 15S RN 120 R5 AY Series 247 Cutoff 247 10S RN 120 R2 FC TL 247 10M XN MT1 R2 FC TL 64 Product Guide Effective Projected Area (EPA) The EPA for the American Revolution Series 247 is 1.6 sq. ft. Approx. Wt. = 36 lbs. For photometric information, visit our website, www.americanelectriclighting.com American Revolution Series 247 and 247 Cutoff 50-150W HPS, 70-175W MH O R D E R I N G I N F O R M AT I O N Example: 2 4 7 1 5 S R N 1 2 0 R 5 A Y E C Wattage / Source Series 247 American Revolution Post Top 05 07 10 15 17 50W 70W 100W 150W 175W S HPS M MH Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Autotransformer CT CWI Autotransformer 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 Refer to ballast matrix on page 101 for compatibility. 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V Distribution R2 R3 R5 RV Type II Type III11 Type V2,11 Type V3.11 Optics AY Acrylic* PY Polycarbonate* FC Full Cutoff12 *Refer to optical matrix below for compatibility Options Paint4 (blank) GY WH BZ Black (standard) Gray White Bronze Lamp LC LD Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Starter6 (blank) Open Board (standard) EC Encapsulated Plug-in11 OP Open Plug-in11 Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Position T3 3 Wire Operation (L1, N, L2 Position)11 Misc. PC Listing11 UL UL Listed SH SS CS CSA Certified 5H NL Fusing10 HS SF Single Fuse (120, 277, 347V) TL DF Double Fuse (208, 240, 480V) LDR Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle5 1 2 3 4 5 6 7 Photocontrol Included per Voltage Specified5 Shorting Cap5 Stainless Steel Hardware 50 Hertz Ballast Cycle7 NEMA Label (2x2) House Side Shield9 Tool-less Entry Ladder Rest13 8 9 10 11 12 13 Voids UL/CSA Listing Four white panels Four clear panels Other colors available, please contact your local American Electric Lighting representative PC, SH not available with NR option HPS only Limited availability, please contact your local American Electric Lighting representative T3 option only available with 240, 480, DT2, DT4, MT2 Acrylic only Not available in MT, TT, DT voltages Not available on FC version Nighttime FriendlyTM optic Ships with unit, field installed Optic Distribution 05S 07S 10S 15S 07M 10M 15M 17M R2 AY R3 AY R5 AY RV AY R2 PY N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N R3 PY R5 PY RV PY R2 FC N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N Product Guide 65 Georgian Series GRP 50-150W HPS, 70-175W MH P R O D U C T O V E R V I E W Features: Two (2) piece cast aluminum housing Castings are hinged and open with a simple 1/4 turn thumb screw for easy maintenance Choice of two (2) mounting arrangements: side entry or post top Lenses are sealed with neoprene gaskets to prevent ingress of dirt or moisture in luminaire. Bottom lens is sealed with a felt gasket for proper breathing of luminaire (top entry and side entry units only) All ballasts are mounted on a ballast plate with quick disconnect, for easy replacement All exposed screws are stainless steel Cast aluminum slipfitter accepts 3” to 3-1/2” O.D. X 4” long tenon or pole. Mounting hardware included A photocell cupola is supplied when ordering the photocell receptacle Mogul base socket Certified by CSA and UL standards Applications: All electrical components warranted by American Electric Lighting's 6-year guarantee Residential areas Architectural landscape lighting Parks, walkways Recreational areas Commercial environments Complies with ANSI: C136.2, C136.10, C136.15, C136.16 DIMENSIONS POST TOP PREFERRED SELECTION CATALOG NUMBERS SIDE MOUNT GRS 10S CT DT1 R2 RD SB CS EC NL PC PY GRS 15S CT DT1 R3 RD CS EC NL PC PY GRP 10S CT DT1 R3 RD SB CS EC NL PC CD PY GRP 15S CT DT1 R3 RD SB CS EC PC NL PY Effective Projected Area (EPA) The EPA for the Georgian is 2.93 sq. ft. Approx. Wt. = 46 lbs. 66 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Georgian Series GRP 50-150W HPS, 70-175W MH O R D E R I N G I N F O R M AT I O N Example: G R P 1 0 S R H 1 2 0 R 3 R D P Y GRP Post Top GRS Side Mount GRL Post Top w/ ladder rest Ballast Wattage / Source Series 05 07 10 15 17 50W 70W 100W 150W 175W M MH S HPS CA CWA Autotransformer CT CWI Autotransformer RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor Refer to ballast matrix on page 102 for compatibility. Voltage 120 208 240 277 347 480 DT1 DT2 MT1 MT2 MT7 TT3 120V 208V 240V 277V 347V 480V Dual Tap 120/240 Wired 120 Dual Tap 120/240 Wired 240 Multi-tap Wired 120 Multi-tap Wired 240 Multi-tap Wired 277 Tri-tap Wired 347 Distribution R2 Roadway Type II R3 Roadway Type III R5 Type 51 Optics RD High Performance Roadway Reflector OA Open Bottom Acrylic2 CR Cone Reflector Options Paint (blank) BZ GY WH SB Black (standard) Bronze Gray White Shibui Brown Terminal Block T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position)3 Listing (blank) CS UL Listing (standard) CSA Certified Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle NR No Receptacle Misc. PC SH NL CH CD CB Photocontrol Included Shorting Cap NEMA Label Decorative Chimney2 Decorative Candle2 Century Base Notes: 1 2 3 4 Available only with OA optics Cannot be used together with other optics T3 option only available with 240, 480, DT2, DT4, MT2 HPS only Side Panels GL Glass PY Polycarbonate AY Acrylic PE Pebbled Glass Starter4 EC Encapsulated Plug-in OP Open Plug-in Product Guide 67 Bainbridge Series 870 50-150W HPS,175W MH P R O D U C T O V E R V I E W Features: Architecturally complimentary design Powdercoated, paint finish Terminal block for ease of wiring A variety of wattages and ballast types Available in HPS and MH Easy access to electrical components Available in a variety of IES distributions E39 mogul base socket standard All electrical components warranted by American Electric Lighting’s 6-year guarantee Complies with ANSI: C136.2, C136.10, C136.15, C136.31 Suitable for -30°C MH / -40°C HPS Applications: Office buildings Shopping centers Malls Apartment/condominium complexes Commercial developments DIMENSIONS 16-1/2” (419) 27” (686) 37” (940) Effective Projected Area (EPA) The EPA for the Bainbridge Series 870 is 3.7 sq. ft. Approx. Wt. = 28 lbs. 68 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Bainbridge Series 870 50-150W HPS,175W MH O R D E R I N G I N F O R M AT I O N Example: 8 7 0 1 0 S C A M T 1 R 3 A Y L C Series 870 Bainbridge Wattage / Source 05 07 10 15 17 50W 70W 100W 150W 175W S HPS M MH Voltage Ballast CA CWA Autotransformer RH Reactor High Power Factor RN Reactor Normal Power Factor XH High Reactance / Lag High Power Factor XN High Reactance / Lag Normal Power Factor 120 208 240 277 480 DT2 MT1 MT2 MT7 120V 208V 240V 277V 480V Dual Tap 120/240 Wired 240 Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Refer to ballast matrix on page 102 for compatibility. Distribution R3 Type III1 R5 Type V1 R0 No Internal Refractor Optics AY Acrylic PY Polycarbonate WC White Polycarbonate Options Paint (blank) BZ Black (standard) Bronze Photocontrol (blank) None BC Button-photocontrol Terminal Block Misc. T2 Wired to L1 & L2 Positions SS T3 3 Wire Operation (L1, N, L2 Position)2 NL Lamp LC LD Notes: 1 Achieved with internal glass refractor 2 T3 option only available with 240, 480, DT2, DT4, MT2 Stainless Steel Hardware NEMA Label Lamp Included, Clear Lamp Included, Deluxe/Coated Product Guide 69 Marietta Series LMD 50-250W HPS, 50-250W MH PP RR O OD DU U CC TT O O VV EE RR VV II EE W W Features: Available in solid or clear top prismatic globe Interchangeable base with a wide variety of globes Symmetric or Asymmetric distribution Available in Semi-Cutoff IES classification Injection-molded, high-impact acrylic or polycarbonate Excellent uniformity, light distribution and efficiency Maximizes pole spacing Base and optical ship separately HPS units standard with encapsulated starter that is located at the socket for quick access Quick disconnect plug for easy maintenance Easy access component door Applications: Photocontrol and terminal block available and located with easy access from component door Streetscapes Walkways Pathways Parks Uplight shield is standard E39 mogul base socket standard Mounts to 3” x 3” pole top tenons DIMENSIONS All electrical components warranted by American Electric Lighting's 6-year guarantee Complies with ANSI: C136.2, C136.10, C136.15, C136.31 Suitable for -30°C MH / -40°C HPS PREFERRED SELECTION CATALOG NUMBERS LMD 10S RN 120 R3 PA PR LMD 10S RN 120 R5 PA PR LMD 10M XN MT1 R3 PA PR LMD 10M XN MT1 R5 PA PR Effective Projected Area (EPA) The EPA for the Marietta Series is 2.7 sq. ft. Approx. Wt. = 24lbs. 70 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Marietta Series LMD 50-250W HPS, 50-250W MH O R D E R I N G I N F O R M AT I O N Example: L M D 1 7 M C A M T 1 R 5 P A P R P C Wattage / Source Series LMD Marietta 05 07 10 15 17 25 S M 50W 70W 100W 150W 175W 250W2 Voltage Ballast HPS MH RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 102 for compatibility. 120 208 240 277 347 480 MT1 MT2 MT7 DT2 TT3 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Dual Tap 120/240 Wired 240V Tri-tap Wired 347V Distribution R3 Type III R5 Type V Options Globe PA PT PN Prismatic Acrylic SolidTop (optical) Prismatic Clear Top Polycarbonate (optical) Prismatic Clear Top Acrylic (optical) Paint3 (blank) Black VG Verde Green BZ Bronze Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Misc PC SH SS BD F5 TL US Locking Type Photocontrol1 Shorting Cap1 Stainless Steel Fasteners (external) Without Decorative Cage Spike Finial5 Tool-less Entry Uplight Shield Notes: 1 For use with PR option 2 250W adds 3” to housing height 3 Other colors available, please contact your local American Electric Lighting representative 4 T3 option only available with 240, 480, DT2, DT4, MT2 5 Standard with PA optic Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 Wire Operations (L1, N, L2 Position)4 Receptacle (blank) No Photocontrol Receptacle (std) PR Photocontrol Receptacle Product Guide 71 Sumter Series LSH 50-250W HPS, 50-250W MH P R O D U C T O V E R V I E W Features: Solid top prismatic globe Interchangeable base with a wide variety of globes Symmetric or Asymmetric distribution Available in Semi-Cutoff IES classification Injection-molded, high-impact acrylic or polycarbonate Excellent uniformity, light distribution and efficiency Maximizes pole spacing Base and optical ship separately HPS units standard with encapsulated starter that is located at the socket for quick access Quick disconnect plug for easy maintenance Easy access component door Applications: Photocontrol and terminal block available and located with easy access from component door Streetscapes Walkways Pathways Parks E39 mogul base socket standard Mounts to 3” x 3” pole top tenons All electrical components warranted by American Electric Lighting's 6-year guarantee DIMENSIONS Complies with ANSI: C136.2, C136.10, C136.15, C136.31 Suitable for -30°C MH / -40°C HPS Effective Projected Area (EPA) The EPA for the Sumter Series is 2.7 sq. ft. Approx. Wt. = 24 lbs. 72 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Sumter Series LSH 50-250W HPS, 50-250W MH O R D E R I N G I N F O R M AT I O N Example: L S H 1 7 M C A 1 2 0 R 5 P A P R L C P C Wattage / Source Series LSH Sumter 05 07 10 15 17 25 S M 50W 70W 100W 150W 175W 250W1 Voltage Ballast HPS MH RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 103 for compatibility. 120 208 240 277 347 480 MT1 MT2 MT7 DT2 TT3 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Dual Tap 120/240 Wired 240 Tri-tap Wired 347V Distribution R3 Type III R5 Type V Options Globe PP PA Prismatic Polycarbonate (optical) Prismatic Acrylic (optical) Paint (blank) Black VG Verde Green BZ Bronze Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Misc PC SH SS Locking Type Photocontrol3 Shorting Cap3 Stainless Steel Fasteners (external) Notes: 1 250W adds 3” to housing height 2 T3 option only available with 240, 480, DT2, DT4, MT2 3 For use with PR option Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 Wire Operations (L1, N, L2 Position)2 Receptacle (blank) No Photocontrol Receptacle (std) PR Photocontrol Receptacle Product Guide 73 Cresthill Classic Series LCR 50-150W HPS, 50-175W MH P R O D U C T O V E R V I E W Features: Interchangeable base with a wide variety of globes Symmetric or Asymmetric distribution Globe available in stepped acrylic and polycarbonate or prismatic acrylic and polycarbonate Base and optical ship separately HPS units standard with encapsulated starter that is located at the socket for quick access Quick disconnect plug for easy maintenance Easy access component door Photocontrol and terminal block available and located with easy access from component door E39 mogul base socket standard Mounts to 3” x 3” pole top tenons Applications: All electrical components warranted by American Electric Lighting's 6-year guarantee Streetscapes Walkways Pathways Parks Complies with ANSI: C136.2, C136.10, C136.15, C136.31 Suitable for -30°C MH / -40°C HPS DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS LCR 10S RN 120 R5 AA PR Effective Projected Area (EPA) The EPA for the Cresthill Classic is 1.4 sq. ft. Approx. Wt. = 37 lbs. 74 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Cresthill Classic Series LCR 50-150W HPS, 50-175W MH O R D E R I N G I N F O R M AT I O N Example: L C R 1 0 S R N 1 2 0 R 5 A P P R L C P R Wattage / Source Series LCR Cresthill 05 07 10 15 17 S M 50W 70W 100W 150W 175W Voltage Ballast HPS MH RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 103 for compatibility. 120 208 240 277 347 480 MT1 MT2 MT7 DT2 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Dual Tap 120/240 Wired 240 Distribution R0 No Internal Refractor1 R3 Type III2 R5 Type V2 Options Globe AP AA PT PN Classic Large Clear Polycarbonate (Non-optical) Classic Large Clear Acrylic (Non-optical) Prismatic Polycarbonate (optical) Prismatic Acrylic (optical) Paint (blank) Black VG Verde Green BZ Bronze Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 Wire Operations (L1, N, L2 Position)3 Receptacle (blank) No Photocontrol Receptacle (std) PR Photocontrol Receptacle Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Misc F5 PC SH SS US 9R Finial Locking Type Photocontrol4 Shorting Cap4 Stainless Steel Fasteners (external) Uplight Shield5 9" Globe Neck Notes: 1 Not available with PN or PT options 2 Achieved with internal glass refractor except with prismatic globes 3 T3 option only available with 240, 480, DT2, DT4, MT2 4 For use with PR options 5 For use with PN and PT only Product Guide 75 Cresthill Sphere Series LCR 50-150W HPS, 50-175W MH P R O D U C T O V E R V I E W Features: Interchangeable base with a wide variety of globes Symmetric or Asymmetric distribution Globe 22” white acrylic or clear polycarbonate Base and optical ship separately HPS units standard with encapsulated starter that is located at the socket for quick access Quick disconnect plug for easy maintenance Easy access component door Photocontrol and terminal block available and located with easy access from component door E39 mogul base socket standard Mounts to 3” x 3” pole top tenons Powdercoat finish Applications: All electrical components warranted by American Electric Lighting's 6-year guarantee Streetscapes Walkways Pathways Parks Complies with ANSI: C136.2, C136.10, C136.15, C136.31 Suitable for -30°C MH / -40°C HPS DIMENSIONS Effective Projected Area (EPA) The EPA for the Cresthill Sphere is 2.5 sq. ft. Approx. Wt. = 22lbs. 76 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Cresthill Sphere Series LCR 50-150W HPS, 50-175W MH O R D E R I N G I N F O R M AT I O N Example: L C R 1 0 S R N 1 2 0 R 5 S Y P R L C P C Wattage / Source Series LCR Cresthill 05 07 10 15 17 S M 50W 70W 100W 150W 175W Voltage Ballast HPS MH RN RH XN XH CA CT 120 208 240 277 480 MT1 MT8 MT2 MT7 DT1 Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 103 for compatibility. DT2 120V 208V 240V 277V 480V Multi-tap Wired 120V Multi-tap Wired 208V Multi-tap Wired 240V Multi-tap Wired 277V Dual Tap 120/240 Wired 120 Dual Tap 120/240 Wired 240 Distribution R0 No Internal Refractor R3 Type III1 R5 Type V1 Options Globe SL SY Sphere White Polycarbonate2 Sphere White Acrylic2 Paint (blank) Black VG Verde Green BZ Bronze Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 Wire Operations (L1, N, L2 Position)3 Lamp LC LD Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated Photocontrol (blank) None PC Locking Type Photocontrol4 Misc SH SS 9R 1 2 3 4 5 Achieved with internal glass refractor Available in 9R only, requires 9R housing T3 option only available with 240, 480, DT2, DT4, MT2 For use with PR options For 9” neck 22” diameter globe is used Shorting Cap4 Stainless Steel Fasteners (external) 9" Globe Neck5 Receptacle (blank) No Photocontrol Receptacle (standard) PR Photocontrol Receptacle Product Guide 77 Cresthill Centennial Series LCR 50-150W HPS, 100-175W MH P R O D U C T O V E R V I E W Features: Interchangeable base with a wide variety of globes Symmetric or Asymmetric distribution Acrylic or polycarbonate globe Base and optical ship separately HPS units standard with encapsulated starter that is located at the socket for quick access Quick disconnect plug for easy maintenance Easy access component door Photocontrol and terminal block available and located with easy access from component door E39 mogul base socket standard Mounts to 3” x 3” pole top tenons Powdercoat finish Applications: All electrical components warranted by American Electric Lighting's 6-year guarantee Streetscapes Walkways Pathways Parks Complies with ANSI: C136.2, C136.10, C136.15, C136.31 Suitable for -30°C MH / -40°C HPS DIMENSIONS Effective Projected Area (EPA) The EPA for the Cresthill Centennial is 1.2 sq. ft. Approx. Wt. = 22lbs. 78 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Cresthill Centennial Series LCR 50-150W HPS, 100-175W MH O R D E R I N G I N F O R M AT I O N Example: L C R 1 0 S R N 1 2 0 R 5 C Y P R L C P C Wattage / Source Series LCR Cresthill 05 07 10 15 17 S M 50W 70W 100W 150W 175W Voltage Ballast HPS MH RN RH XN XH CA CT 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 103 for compatibility. 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347 Dual Tap 120/240 Wired 240 Distribution RO No Internal Refractor R3 Type III1 R5 Type V1 Options Globe CE CW CY CM Centennial Large Clear Acrylic (Non-optical) Centennial Large White Polycarbonate2 Centennial Large Clear Acrylic Centennial Medium Clear Acrylic Paint (blank) Black VG Verde Green BZ Bronze Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operations (L1, N, L2 Position3 Receptacle (blank) No Photocontrol Receptacle (standard) PR Photocontrol Rseceptacle Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Misc PC SH SS 9R Twist-off Photocontrol4 Shorting Cap4 Stainless Steel Fasteners (external) 9" Globe Neck Notes: 1 2 3 4 Achieved with internal glass refractor For use with 9R option only, requires 9R housing T3 option only available with 240, 480, DT2, DT4, MT2 For use with PR options Product Guide 79 Cresthill Glass Series LCR 50-250W HPS, 50-250W MH P R O D U C T O V E R V I E W Features: Interchangeable base with a wide variety of globes Symmetric or Asymmetric distribution Prismatic glass globe Base and optical ship separately HPS units standard with encapsulated starter that is located at the socket for quick access Quick disconnect plug for easy maintenance Easy access component door Photocontrol and terminal block available and located with easy access from component door E39 mogul base socket standard Mounts to 3” x 3” pole top tenons Powdercoat finish Applications: All electrical components warranted by American Electric Lighting's 6-year guarantee Streetscapes Walkways Pathways Parks Complies with ANSI: C136.2, C136.10, C136.15, C136.31 Suitable for -30°C MH / -40°C HPS DIMENSIONS Effective Projected Area (EPA) The EPA for the Cresthill Glass is 1.4 sq. ft. Approx. Wt. = 37lbs. 80 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Cresthill Glass Series LCR 50-250W HPS, 50-250W MH O R D E R I N G I N F O R M AT I O N Example: L C R 1 0 S R N 1 2 0 R 5 P G P R L C P C Wattage / Source Series LCR Cresthill 05 07 10 15 17 25 S M 50W 70W 100W 150W 175W 250W1 Voltage Ballast HPS MH RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 104 for compatibility. 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347 Dual Tap 120/240 Wired 240 Distribution R3 Type III R5 Type V Options Globe PG Prismatic Glass Paint (blank) Black VG Verde Green BZ Bronze Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 Wire Operations (L1, N, L2 Position)2 Notes: Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Misc PC SH SS F5 Locking Type Photocontrol3 Shorting Cap3 Stainless Steel Fasteners (external) Finial 1 250 W adds 3” to cast housing height 2 T3 option only available with 240, 480, DT2, DT4, MT2 3 For use with PR options Receptacle (blank) No Photocontrol Receptacle (std) PR Photocontrol Receptacle Product Guide 81 Lexington Series LLX 50-150W HPS, 100-175W MH P R O D U C T O V E R V I E W Features: Available with or without spikes Interchangeable base with a wide variety of lenses Symmetric or Asymmetric distribution Decorative spike finial standard Rugged cast-aluminum housing Lens available in acrylic, polycarbonate or clear glass Base and optical ship separately HPS units standard with encapsulated starter that is located at the socket for quick access Quick disconnect plug for easy maintenance Easy access component door Photocontrol and terminal block available and located with easy access from component door Applications: E39 mogul base socket standard Streetscapes Walkways Pathways Parks Mounts to 3” x 3” pole top tenons All electrical components warranted by American Electric Lighting's 6-year guarantee Complies with ANSI: C136.2, C136.10, C136.15, C136.31 DIMENSIONS Suitable for -30°C MH / -40°C HPS Effective Projected Area (EPA) The EPA for the Lexington is 3.1 sq. ft. Approx. Wt. = 33 lbs. 82 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Lexington Series LLX 50-150W HPS, 100-175W MH O R D E R I N G I N F O R M AT I O N Example: L L X 1 0 S R N 1 2 0 R 5 A Y P R L C P C Series LLX Lexington Wattage / Source 05 07 10 15 17 S M 50W 70W 100W 150W 175W Voltage Ballast HPS MH RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 104 for compatibility. 120 208 240 277 347 480 MT1 MT2 MT7 DT2 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Dual Tap 120/240 Wired 240 Distribution R0 No Internal Refractor R3 Type III1 R5 Type V1 Options Globe AY PY GL Acrylic Polycarbonate Glass Paint (blank) Black VG Verde Green BZ Bronze Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 Wire Operations (L1, N, L2 Position)2 Receptacle (blank) No Photocontrol Receptacle (std) PR Photocontrol Receptacle Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Misc PC SH SS NS Locking Type Photocontrol3 Shorting Cap3 Stainless Steel Fasteners (external) No Spikes on LLX Housing Notes: 1 Achieved with internal glass refractor 2 T3 option only available with 240, 480, DT2, DT4, MT2 3 For use with PR option Product Guide 83 Branson Series LBR 50-150W HPS, 50-175W MH P R O D U C T O V E R V I E W Features: Ornamental aluminum canopy top Interchangeable base with a variety of globes Symmetric or Asymmetric distribution Base and optical ship separately Powdercoat finish HPS units standard with encapsulated starter that is located at the socket for quick access Quick disconnect plug for easy maintenance Easy access component door Photocontrol and terminal block available and located with easy access from component door E39 mogul base lamp holder standard Mounts to 3” x 3” pole top tenons Applications: Available in stippled acrylic or polycarbonate globes Streetscapes Walkways Pathways Parks All electrical components warranted by American Electric Lighting's 6-year guarantee Complies with ANSI: C136.2, C136.10, C136.15, C136.31 Suitable for -30°C MH / -40°C HPS DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS LBR 10S RN 120 R3 AY PR LBR 10S RN 120 R5 AY PR 13” (330) 38” (965) 3-1/4” (83) Effective Projected Area (EPA) The EPA for the Branson is 2.3 sq. ft. Approx. Wt. = 22 lbs. 84 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Branson Series LBR 50-150W HPS, 50-175W MH O R D E R I N G I N F O R M AT I O N Example: L B R 1 5 S C A M T 1 R 5 P Y L C Series LBR Branson Wattage / Source 05 07 10 15 17 S M 50W 70W 100W 150W 175W Voltage Ballast HPS MH RN RH XN XH CA CT Reactor Normal Power Factor Reactor High Power Factor High Reactance/Lag NPF High Reactance/Lag HPF CWA Auto-Reg CWI Refer to ballast matrix on page 104 for compatibility. 120 208 240 277 347 480 MT1 MT2 MT7 DT2 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Dual Tap 120/240 Wired 240 Distribution RO No Internal Refractor R3 Type III1 R5 Type V1 Options Globe AY PY Acrylic Polycarbonate Paint2 (blank) Black Terminal Block (blank) Terminal Block (std) T2 Wired to L1 & L2 Positions T3 3 Wire Operations (L1, N, L2 Position)3 Receptacle (blank) No Photocontrol Receptacle (std) PR Photocontrol Receptacle Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Misc PC SH SS Locking Type Photocontrol4 Shorting Cap4 Stainless Steel Fasteners (external) Notes: 1 Achieved with internal glass refractor except with prismatic globes 2 Other colors available, please contact your local American Electric Lighting representative 3 T3 option only available with 240, 480, DT2, DT4, MT2 4 For use with PR option Product Guide 85 Contempo Series 245 50-400W HPS, 70-400 MH P R O D U C T O V E R V I E W Features: Die-cast aluminum housing and spun aluminum hood for long-life performance Optical assembly designed for maximum performance Multi-gasketing to provide weatherproof protection of optical assembly for full illumination performance Hinged hood and captive screw latching provision afford quick, easy access to electrical and optical area for relamping or servicing Available with two different style hoods and an added scroll option for a more decorative look Cone mounting fitter with three set screws allows secure installation to pole sizes 2-3/8" or 3" O.D. Refractor available in tempered glass, acrylic and polycarbonate Available in a variety of IES light distributions patterns E39 mogul base socket standard Applications: All electrical components warranted by American Electric Lighting's 6-year guarantee Streetscapes Walkways Pathways Parks Complies with ANSI: C136.2, C136.10, C136.15, C136.16 Suitable for -30°C MH / -40°C HPS PREFERRED SELECTION CATALOG NUMBERS 245 10S RN 120 R5 AY 245 15S RN 120 R5 AY 245 25S CA MT1 R5 GL 245 15S CA MT1 R5 AY DIMENSIONS DIMENSIONS SCROLL DESIGN OPTION Effective Projected Area (EPA) The EPA for the Contempo Series 245 is 1.3 sq. ft. Approx. Wt. = 32 lbs. 86 Product Guide Effective Projected Area (EPA) The EPA for the Decorative Scroll Option is 1.8 sq. ft. Approx. Wt. = 32 lbs. For photometric information, visit our website, www.americanelectriclighting.com Contempo Series 245 50-400W HPS, 70-400W MH O R D E R I N G I N F O R M AT I O N O R D E R I N G I N F O R M AT I O N Example: 2 4 5 1 0 S R N 1 2 0 R 3 G L S D P C Wattage / Source Series 245 Contempo Post Top 05 07 10 13 14 15 17 25 40 RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Autotransformer CT CWI Autotransformer SC SCWA MR Mag Reg (3 coil) 50W S HPS 70W M MH 100W 100/150 Wired 100 100/150 Wired 150 150W 175W 250W 400W Distribution Voltage Ballast 120 208 240 277 480 MT1 MT2 MT7 TT3 DT2 5T4 120V 208V 240V 277V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 wired 240V 5-tap Wired 480V7 R2 Type II R3 Type III R5 Type V Optics GL Glass AY Acrylic6 PY Polycarbonate6 Refer to ballast matrix on page 105 for compatibility. Refer to optical matrix below for compatibility Options Paint1 (blank) BK WH BZ Gray (standard) Black White Bronze Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position)8 Listing UL CS UL Listed CSA Certified Fusing2 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Starter4 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Hood Style (see line art) (blank) Style A SD Style D Misc. PC SS 5H NL DD SH Photocontrol Included per Voltage Specified3 Stainless Steel Hardware 50 Hertz Ballast Cycle5 NEMA Label Decorative Scroll Design9 Shorting Cap3 Notes: 1 Other colors available, please contact your local American Electric Lighting representative 2 Voids UL/CSA not available in MT, TT, DT, voltages 3 PC, SH not available with NR option 4 Available in HPS only 5 Limited availability, please contact your local American Electric Lighting representative 6 Available in 250W maximum 7 Available in 250W and 400W HPS and MH 8 T3 option only available with 240, 480, DT2, DT4, MT2 9 Scroll color must be specified Optic Distribution 05S 07S 10S 15S 20S 25S 31S 40S 17M 25M 40M R2 AY R3 AY R5 AY R2 PY R3 PY R5 PY N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N - R2 GL N N N N N N N N N N N R3 GL R5 GL N N N N N N N N N N N N N N N N N N N N N N Product Guide 87 TwistPack Series TWT 50-250W HPS, 70-250W MH P R O D U C T O V E R V I E W Features: Unique locking type feature with locking screw that allows easy removal of optical assembly from slipfitter casting Slipfitter casting houses ballast. It will fit over a post having top diameter of 3-1/2” (4”O.D.) or 3” (3-1/2”O.D.) Slipfitter casting is secured to post by three Allen-head locking screws Some components of the ballast (e.g. capacitors and/or ignitors) depending on wattage or type, may extend below the slipfitter casting and may have to fit in the top of the pole Aluminum hood covers are either 24” or 28” diameter Refractors offered in IES Type II, and V distributions Available in polycarbonate or acrylic refractors Mogul base socket Natural aluminum finish is standard, other colors available NEMA type photocell receptacle is standard Applications: CSA certified option available All electrical components warranted by American Electric Lighting's 6-year guarantee Shopping malls Parks Campuses Residential streets Condominiums Walkways Complies with ANSI: C136.2, C136.10, C136.15, C136.16 DIMENSIONS H4 HOOD PREFERRED SELECTION CATALOG NUMBERS H8 HOOD Effective Projected Area (EPA) The EPA for the TwistPack H4 Hood is 1.40 sq. ft. The EPA for the TwistPack H8 Hood is 1.28 sq. ft. Approx. Wt. = 41 lbs. 88 Product Guide For photometric information, visit our website, www.americanelectriclighting.com TWT 10S RN 120 R5 AY H8 CS NR EC TWT 15S RN 120 R5 AY H8 CS NR EC TwistPack Series TWT 50-250W HPS, 70-250W MH O R D E R I N G I N F O R M AT I O N Example: T W T 1 5 S R N 1 2 0 R 5 A Y H 8 Wattage / Source Series TWT TwistPack 05 07 10 15 17 25 50W 70W 100W 150W 175W 250W Voltage Ballast M Metal Halide S HPS CA CWA Autotransformer CT CWI Autotransformer RH Reactor High Power Factor RN Reactor Normal Power Factor XH High Reactance/Lag High Power Factor XN High Reactance/Lag Normal Power Factor 120 208 240 277 347 480 DT2 MT1 MT2 MT7 5T4 R2 120V R5 208V 240V 277V 347V 480V Dual Tap 120/240 Wired 240 Multi-tap Wired 120 Multi-tap Wired 240 Multi-tap Wired 277 5-tap Wired 4806 Distribution Roadway Type II Type V Optics AY Acrylic PY Polycarbonate1 Hood H4 H8 24” hood2 28” hood Refer to ballast matrix on page 105 for compatibility. Options Paint UP BK BZ GY WH Unpainted (standard) Black Bronze Gray White Lamp LC LD Starter5 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Terminal Block Misc. T2 Wired to L1 & L2 Positions PC T3 3 Wire Operation (L1, N, L2 Position)4 Listing CS CSA Certified Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated NL SH SS 1 2 3 4 5 6 PY available in HPS only H4 available in 175W and below PC and SH not available with NR option T3 option only available with 240, 480, DT2, DT4, MT2 HPS only Available in 250W Photocontrol Included per Voltage Specified3 NEMA Label Shorting Cap3 Stainless Steel Hardware Supply Wire P Pre-wired to Terminal Block S Supply Wire Included in Carton See page 118. Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 Product Guide 89 Decorative Poles Chadsworth Series Cast Aluminum Posts Extruded Shaft P R O D U C T O V E R V I E W Features: INSTALLATION The post shall be provided with four, hot-dip galvanized L-type anchor bolts to be installed on an 10" - 12" diameter bolt circle. A door shall be provided in the base for anchorage and wiring access. A grounding screw shall be provided inside the base opposite the door. MATERIALS The base shall be heavy wall, copper free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B26-95. The straight shafts shall be extruded from aluminum, ASTM 6061 alloy, heat treated to a T6 temper. The tapered shaft shall be extruded from aluminum, ASTM 6063 alloy, spun to a tapered shape, then heat treated to a T6 temper. All hardware shall be tamper resistant stainless steel. Anchor bolts to be completely hot-dip galvanized. CONSTRUCTION The shaft shall be double welded to the base casting and shipped as one piece for maximum structural integrity. The shaft shall be circumferentially welded inside the base casting at the top of the access door, and externally where the shaft exits the base. All exposed welds below 8’ shall be ground smooth. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per Section 5 of ANSI/AWS D1.2-90. DIMENSIONS The post shall be 8’- 16’ in height (depending on customer selection) with a 16" diameter base. The shaft diameter varies depending on shaft type selected. (See page 91.) At the top of the post, an integral 3" O.D. x 3" tenon with a transitional donut shall be provided for luminaire mounting. Applications: Streetscapes Walkways Pathways Parks 90 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Decorative Poles Chadsworth Series Cast Aluminum Posts Extruded Shaft O R D E R I N G I N F O R M AT I O N Example: P X C H 1 6 1 2 S 5 A N B K A E L AEL Series Height PX CH16 Chadsworth 8’ 10’ 12’ 14’ 16’1 Shaft Type S4 S5 F4 F5 T4 T5 Smooth 4"Ø Smooth 5"Ø Fluted 4"Ø Fluted 5"Ø Tapered 4"-3"Ø Tapered 5"-3"Ø Finish2 ANBK ANDB ANDG CM CS Black Bronze Dark Green Custom Match Custom Select RAL colors Options Manufacturing Code _________ Receptacles _________ Banner Arms _________ Flagpole Holders _________ Signage AEL (See Accessories section or contact your local AEL representative.) Notes: 1 16' height not available for S4, F4, or T4 (any 4"Ø) Shaft Type 2 For finish specifications and color options, please contact your local American Electric Lighting representative DIMENSIONS Product Guide 91 Decorative Poles New Albany Series Cast Aluminum Posts Extruded Shaft P R O D U C T O V E R V I E W Features: INSTALLATION The post shall be provided with four, hot-dip galvanized L-type anchor bolts to be installed on an 12" diameter bolt circle. A door shall be provided in the base for anchorage and wiring access. A grounding screw shall be provided inside the base opposite the door. MATERIALS The base shall be heavy wall, copper free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B26-95. The straight shafts shall be extruded from aluminum, ASTM 6061 alloy, heat treated to a T6 temper. The tapered shaft shall be extruded from aluminum, ASTM 6063 alloy, spun to a tapered shape, then heat treated to a T6 temper. All hardware shall be tamper resistant stainless steel. Anchor bolts to be completely hot-dip galvanized. Smooth Fluted CONSTRUCTION The shaft shall be double welded to the base casting and shipped as one piece for maximum structural integrity. The shaft shall be circumferentially welded inside the base casting at the top of the access door, and externally where the shaft exits the base. All exposed welds below 8’ shall be ground smooth. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per Section 5 of ANSI/AWS D1.2-90. DIMENSIONS The post shall be 8’- 16’ in height (depending on customer selection) with a 16" diameter base. The shaft diameter varies depending on shaft type selected. (See page 93.) At the top of the post, an integral 3" O.D. x 3" tenon with a transitional donut shall be provided for luminaire mounting. Tapered Applications: Streetscapes Walkways Pathways Parks 92 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Decorative Poles New Albany Series Cast Aluminum Posts Extruded Shaft O R D E R I N G I N F O R M AT I O N Example: P X N Y 1 7 1 2 S 5 A N B K A E L AEL Series Height PX NY17 New Albany 8’ 10’ 12’ 14’ 16’1 Finish2 Shaft Type S4 S5 F4 F5 T4 T5 Smooth 4"Ø Smooth 5"Ø Fluted 4"Ø Fluted 5"Ø Tapered 4"-3"Ø Tapered 5"-3"Ø ANBK ANDB ANDG CM CS Black Bronze Dark Green Custom Match Custom Select RAL colors Options Manufacturing Code _________ Receptacles _________ Banner Arms _________ Flagpole Holders _________ Signage (See Accessories section or contact your local AEL representative.) Notes: 1 16' height not available for S4, F4, or T4 (any 4"Ø) Shaft Type. 2 For finish specifications and color options, please contact your local American Electric Lighting representative. DIMENSIONS Product Guide 93 Decorative Poles Statesboro Series Cast Aluminum Posts Extruded Shaft P R O D U C T O V E R V I E W Features: INSTALLATION The post shall be provided with four, hot-dip galvanized L-type anchor bolts to be installed on an 9.5" diameter bolt circle. A door shall be provided in the base for anchorage and wiring access. A grounding screw shall be provided inside the base opposite the door. MATERIALS The base shall be heavy wall, copper free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B26-95. The straight shafts shall be extruded from aluminum, ASTM 6061 alloy, heat treated to a T6 temper. The tapered shaft shall be extruded from aluminum, ASTM 6063 alloy, spun to a tapered shape, then heat treated to a T6 temper. All hardware shall be tamper resistant stainless steel. Anchor bolts to be completely hot-dip galvanized. Applications: Streetscapes Walkways Pathways Parks 94 Product Guide CONSTRUCTION The shaft shall be double welded to the base casting and shipped as one piece for maximum structural integrity. The shaft shall be circumferentially welded inside the base casting at the top of the access door, and externally where the shaft exits the base. All exposed welds below 8’ shall be ground smooth. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per Section 5 of ANSI/AWS D1.2-90. DIMENSIONS The post shall be 8’- 14’ in height (depending on customer selection) with a 16" diameter base. The shaft diameter varies depending on shaft type selected. (See page 95.) At the top of the post, an integral 3" O.D. x 3" tenon with a transitional donut shall be provided for luminaire mounting. . For photometric information, visit our website, www.americanelectriclighting.com Decorative Poles Statesboro Series Cast Aluminum Posts Extruded Shaft O R D E R I N G I N F O R M AT I O N Example: P X S 9 1 2 S 4 A N B K A E L AEL Series Height PX S9 Statesboro 8’ 10’ 12’ 14’ Finish2 Shaft Type S4 Smooth 4"Ø F4 Fluted 4"Ø T4 Tapered 4"-3"Ø ANBK ANDB ANDG CM CS Black Bronze Dark Green Custom Match Custom Select RAL colors Options Manufacturing Code _________ Receptacles _________ Banner Arms _________ Flagpole Holders _________ Signage (See Accessories section or contact your local AEL representative.) DIMENSIONS Product Guide 95 Decorative Poles Waycross Series Cast Aluminum Posts Extruded Shaft P R O D U C T O V E R V I E W Features: INSTALLATION The post shall be provided with four, hot-dip galvanized L-type anchor bolts to be installed on an 12" diameter bolt circle. A door shall be provided in the base for anchorage and wiring access. A grounding screw shall be provided inside the base opposite the door. MATERIALS The base shall be heavy wall, copper free, cast aluminum produced from certified ASTM 356.1 ingot per ASTM B-179-95a or ASTM B26-95. The straight shafts shall be extruded from aluminum, ASTM 6061 alloy, heat treated to a T6 temper. The tapered shaft shall be extruded from aluminum, ASTM 6063 alloy, spun to a tapered shape, then heat treated to a T6 temper. All hardware shall be tamper resistant stainless steel. Anchor bolts to be completely hot-dip galvanized. CONSTRUCTION The shaft shall be double welded to the base casting and shipped as one piece for maximum structural integrity. The shaft shall be circumferentially welded inside the base casting at the top of the access door, and externally where the shaft exits the base. All exposed welds below 8’ shall be ground smooth. All welding shall be per ANSI/AWS D1.2-90. All welders shall be certified per Section 5 of ANSI/AWS D1.2-90. DIMENSIONS The post shall be 8’- 16’ in height (depending on customer selection) with a 16" diameter base. The shaft diameter varies depending on shaft type selected. (See page 97.) At the top of the post, an integral 3" O.D. x 3" tenon with a transitional donut shall be provided for luminaire mounting. . Applications: Streetscapes Walkways Pathways Parks 96 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Decorative Poles Waycross Series Cast Aluminum Posts Extruded Shaft O R D E R I N G I N F O R M AT I O N Example: P X W 1 7 1 2 S 5 A N B K A E L AEL Series PX W17 Waycross 8’ 10’ 12’ 14’ 16’1 Finish2 Shaft Type Height S4 S5 F4 F5 T4 T5 Smooth 4"Ø Smooth 5"Ø Fluted 4"Ø Fluted 5"Ø Tapered 4"-3"Ø Tapered 5"-3"Ø ANBK ANDB ANDG CM CS Black Bronze Dark Green Custom Match Custom Select RAL colors Options Manufacturing Code _________ Receptacles _________ Banner Arms _________ Flagpole Holders _________ Signage AEL (See Accessories section or contact your local AEL representative.) Notes: 1 16' height not available for S4, F4, or T4 (any 4"Ø) Shaft Type. 2 For finish specifications and color options, please contact your local American Electric Lighting representative. DIMENSIONS Product Guide 97 Decorative Poles Weatherproof Receptacles External, Post Shaft Location P R O D U C T O V E R V I E W Features: INSTALLATION External receptacles are typically installed above pedestrian level for special event uses and decorative seasonal lighting. CONSTRUCTION Ground fault circuit interrupter receptacles. Test/Reset buttons on face of receptacles. All cast aluminum covers, not plastic. (Paintable to match post color). Weatherproof “While-in-Use” covers in two sizes. Receptacle with Wet Location While Closed Cover Catalog part # FG-S SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted in the post. The receptacle shall be UL Listed according to E-48380 and UL 943 Class A and UL 498. The receptacle shall have a cast aluminum, UL Listed cover that is suitable for wet locations while not in use. The receptacle and cover shall mount to an outlet opening, in the post shaft, with a gasket and stainless steel screws. Receptacle with Small, In-Use Wet Location Cover Catalog part # FGIUS-S SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted in the post. The receptacle shall be UL Listed according to E-48380 and UL 943 Class A and UL 498. The receptacle shall have a cast aluminum, lockable, UL Listed cover that is suitable for wet locations while in use and complies with NEC Article 41057(b). The cover shall accept most common cord sets up to 3/8” diameter (14/3). The receptacle and cover shall mount to an outlet opening, in the post shaft, with a gasket and stainless steel screws. Receptacle with Large, In-Use Wet Location Cover Catalog part # FGIUL-S SPECIFICATIONS A 20 amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted in the post. The receptacle shall be UL Listed according to E-48380 and UL 943 Class A and UL 498. The receptacle shall have a cast aluminum, lockable, UL Listed cover that is suitable for wet locations while in use and complies with NEC Article 41057(b). The cover shall accept most common cord sets up to 1/2” diameter (12/3). The receptacle and cover shall mount to an outlet opening, in the post shaft, with a gasket and stainless steel screws. 98 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Decorative Poles Weatherproof Receptacles External, Post Shaft Location P R O D U C T O V E R V I E W Features: INSTALLATION Internal receptacles are typically installed for use by authorized personnel for special events and owner maintenance purposes. CONSTRUCTION Ground fault circuit interrupter receptacles. Test and reset buttons on face of receptacles. All cast aluminum covers, not plastic. Receptacle with Weatherproof Box and Cover Catalog part # RB/GFI/WPC SPECIFICATIONS A 20amp, 125 volt, ground fault circuit interrupter duplex receptacle shall be mounted inside the post base, facing toward the access door. The receptacle shall be UL Listed according to E-48380 and UL 943 Class A and UL 498. The receptacle shall be mounted in a cast aluminum box and cover that is suitable for wet locations while not in use. The receptacle and cover shall mount to a outlet box with a gasket and stainless steel screws. Product Guide 99 Decorative and Post Top Lighting B A L L A S T M AT R I C E S Valiant Watts 05S 07S 07M 10S 10M 13S 15S 15M 17M 20S 25S 25M 120 RN, RH CA, CT, RH, RN XH, XN RN, RH, CA, CT XH, XN, CA RN, RH RN, RH, CA, CT XN, XH CA CA XN, XH, CA CA 208 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA CA 240 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA RN, RH, CA XN, XH, CA CA MT7 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA CA TT3 XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH CA CA CA, CT CA, CT 277 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH, CA XN, XH, CA, CT XN, XH CA CA CA CA 347 XN, XH XN, XH XN, XH, CT XN, XH XN, XH CA CA - 480 XN, XH XN, XH, CA XN, XH, CA CA CA CA CA DT2 XN, XH, CA, CT XN, XH XH, XN, CA, CT XN, XH XN, XH CA CA XN, XH, CA CA MT1 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA CA Valiant continued Watts 05S 07S 07M 10S 10M 13S 15S 15M 17M 20S 25S 25M MT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA CA American Revolution Deluxe Series Watts 05S 07S 07M 10S 10M 13S 14S 15S 15M 17M 120 RH, RN RN, RH, CA, CT XN, XH RN, RH, CA, CT XH, XN, CA RH, RN RH, RN RN, RH, CA, CT XN, XH CA 208 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA 240 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA 277 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH, CA XN, XH, CA, CT XN, XH CA 347 XN, XH XN, XH XN, XH, CT XN, XH XN, XH CA 480 XN, XH XN, XH, CA XN, XH, CA CA American Revolution Deluxe Series continued Watts 05S 07S 07M 10S 10M 13S 14S 15S 15M 17M 100 MT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA Product Guide MT7 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA TT3 XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH CA For photometric information, visit our website, www.americanelectriclighting.com DT2 XH, XN, CA, CT XN, XH XH, XN, CA, CT XN, XH XN, XH CA MT1 XH, XN, CA, CT XN, XH XH, XN, CA, CT XN, XH XH, XN, CA, CT XN, XH CA Decorative and Post Top Lighting B A L L A S T M AT R I C E S American Revolution Series 247 Watts 05S 07S 07M 10S 10M 13S 14S 15S 15M 17M 120 RH, RN RN, RH, CA, CT XN, XH RN, RH, CA, CT XH, XN, CA RH, RN RH, RN RN, RH, CA, CT XN, XH CA 208 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA 240 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA 277 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH, CA XN, XH, CA, CT XN, XH CA 347 XN, XH XN, XH XN, XH, CT XN, XH XN, XH CA 480 XN, XH XN, XH, CA XN, XH, CA CA DT2 XH, XN, CA, CT XN, XH XH, XN, CA, CT XN, XH XN, XH CA MT1 XH, XN, CA, CT XN, XH XH, XN, CA, CT XN, XH XH, XN, CA, CT XN, XH CA 277 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH, CA XN, XH, CA, CT XN, XH CA 347 XN, XH XN, XH XN, XH, CT XN, XH XN, XH CA 480 XN, XH XN, XH, CA XN, XH, CA CA DT2 XH, XN, CA, CT XN, XH XH, XN, CA, CT XN, XH XN, XH CA MT1 XH, XN, CA, CT XN, XH XH, XN, CA, CT XN, XH XH, XN, CA, CT XN, XH CA American Revolution Series 247 continued Watts 05S 07S 07M 10S 10M 13S 14S 15S 15M 17M MT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA MT7 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA TT3 XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH CA American Revolution Cutoff Series 247 Watts 05S 07S 07M 10S 10M 13S 14S 15S 15M 17M 120 RH, RN RN, RH, CA, CT XN, XH RN, RH, CA, CT XH, XN, CA RH, RN RH, RN RN, RH, CA, CT XN, XH CA 208 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA 240 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA American Revolution Cutoff Series 247 continued Watts 05S 07S 07M 10S 10M 13S 14S 15S 15M 17M MT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA MT7 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA TT3 XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH CA Product Guide 101 Decorative and Post Top Lighting B A L L A S T M AT R I C E S Georgian Series GRP Wattage 05S 07S 07M 10S 10M 15S 15M 17M 120 RN,RH RN, RH, CA, CT XN, XH RN, RH, CA, CT XN, XH, CA RN, RH, CA, CT XN, XH CA 208 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA 240 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA 277 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH, CA XN, XH, CA, CT XN, XH CA 347 XN, XH XN, XH XN, XH, CT XN, XH XN, XH CA 480 XN, XH XN, XH, CA XN, XH, CA CA DT1 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH CA MT1 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA Georgian Series GRP continued Wattage 05S 07S 07M 10S 10M 15S 15M 17M MT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA MT7 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA TT3 XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH CA Bainbridge Series 870 Watts 05S 07S 10S 15S 17M 120 RN RN, RH, CA, CT RN, RH, CA, CT RN, RH, CA, CT CA 208 XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT CA 240 XN, XH, CA, CT XN, XH, CA, CT XN, XH, CA, CT CA 277 XN, XH, CA XN, XH, CA, CT XN, XH, CA, CT CA 480 CA CA CA CA DT2 XN, XH, CA, CT N, XH, CA, CT XN, XH, CA, CT - MT1 CA, CT CA, CT CA, CT - MT2 CA, CT CA, CT CA, CT CA MT7 CA, CT CA, CT CA, CT CA Marietta Series LMD Wattage 05S 07S 07M 10S 10M 15S 15M 17M 25S 25M 120 RN,RH RN, RH, CA, CT XN, XH RN, RH, CA, CT XN, XH, CA RN, RH, CA, CT XN, XH CA XN, XH, CA CA 208 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA 240 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA XN, XH, CA CA 277 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH, CA XN, XH, CA, CT XN, XH CA CA CA 347 XN, XH XN, XH XN, XH, CT XN, XH XN, XH CA CA - 480 XN, XH XN, XH, CA XN, XH, CA CA CA CA Marietta Series LMD continued Wattage 05S 07S 07M 10S 10M 15S 15M 17M 25S 25M 102 MT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA Product Guide MT7 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA TT3 XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH CA CA, CT CA, CT For photometric information, visit our website, www.americanelectriclighting.com DT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH CA XN, XH, CA CA MT1 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA Decorative and Post Top Lighting B A L L A S T M AT R I C E S Sumter Series LSH Wattage 05S 07S 07M 10S 10M 15S 15M 17M 25S 25M 120 RN,RH RN, RH, CA, CT XN, XH RN, RH, CA, CT XN, XH, CA RN, RH, CA, CT XN, XH CA XN, XH, CA CA 208 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA 240 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA XN, XH, CA CA 277 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH, CA XN, XH, CA, CT XN, XH CA CA CA 347 XN, XH XN, XH XN, XH, CT XN, XH XN, XH CA CA - 480 XN, XH XN, XH, CA XN, XH, CA CA CA CA DT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH CA XN, XH, CA CA MT1 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA 277 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH, CA XN, XH, CA, CT XN, XH CA 347 XN, XH XN, XH XN, XH, CT XN, XH XN, XH CA 480 XN, XH XN, XH, CA XN, XH, CA CA DT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH CA MT1 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA Sumter Series LSH continued Wattage 05S 07S 07M 10S 10M 15S 15M 17M 25S 25M MT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA MT7 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA TT3 XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH CA CA, CT CA, CT Cresthill Series LCR - Classic, Sphere and Centennial Wattage 05S 07S 07M 10S 10M 15S 15M 17M 120 RN,RH RN, RH, CA, CT XN, XH RN, RH, CA, CT XN, XH, CA RN, RH, CA, CT XN, XH CA 208 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA 240 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA Cresthill Series LCR - Classic, Sphere and Centennial continued Wattage 05S 07S 07M 10S 10M 15S 15M 17M MT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA MT7 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA TT3 XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH CA Product Guide 103 Decorative and Post Top Lighting B A L L A S T M AT R I C E S Cresthill Series LCR - Glass Wattage 05S 07S 07M 10S 10M 15S 15M 17M 25S 25M 120 RN,RH RN, RH, CA, CT XN, XH RN, RH, CA, CT XN, XH, CA RN, RH, CA, CT XN, XH CA XN, XH, CA CA 208 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA 240 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA XN, XH, CA CA 277 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH, CA XN, XH, CA, CT XN, XH CA CA CA 347 XN, XH XN, XH XN, XH, CT XN, XH XN, XH CA CA - 480 XN, XH XN, XH, CA XN, XH, CA CA CA CA DT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH CA XN, XH, CA CA MT1 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA Cresthill Series LCR - Glass continued Wattage 05S 07S 07M 10S 10M 15S 15M 17M 25S 25M MT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA MT7 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA TT3 XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH CA CA, CT CA, CT Lexington LLX Watts 120 208 05S RH,RN 07S RN, RH, CA, CT XN, XH, CA, CT 07M XN, XH XN, XH 10S RN, RH, CA, CT XN, XH, CA, CT 10M XN, XH, CA XN, XH 15S RH, RN, CA, CT XN, XH, CA, CT 15M XN, XH XN, XH 17M CA CA 240 277 XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH CA CA 347 XN, XH XN, XH XN, XH, CT XN, XH XN, XH CA 480 XN, XH XN, XH, CA XN, XH, CA CA DT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH CA MT1 MT2 XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH CA CA MT7 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA TT3 XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH CA Branson LBR Watts 120 208 05S RH,RN 07S RN, RH, CA, CT XN, XH, CA, CT 07M XN, XH XN, XH 10S RN, RH, CA, CT XN, XH, CA, CT 10M XN, XH, CA XN, XH 15S RH, RN, CA, CT XN, XH, CA, CT 15M XN, XH XN, XH 17M CA CA 104 Product Guide 240 277 XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH CA CA 347 XN, XH XN, XH XN, XH, CT XN, XH XN, XH CA 480 XN, XH XN, XH, CA XN, XH, CA CA DT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH CA MT1 MT2 XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH XN, XH, CA, CT XN, XH, CA, CT XN, XH XN, XH CA CA For photometric information, visit our website, www.americanelectriclighting.com MT7 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA TT3 XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH CA Decorative and Post Top Lighting B A L L A S T M AT R I C E S Contempo Series 245 Watts 05S 07S 07M 10S 10M 13S 14S 15S 15M 17M 20S 25S 25M 31S 40S 40M 120 RN, RH RN, RH, CA, CT XN, XH RN, RH, CA, CT XN, XH, CA RN, RH RN, RH RN, RH, CA, CT XN, XH CA CA XN, XH, CA CA CA, CT CA, CT 208 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA CA CA, CT CA 240 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA RN, RH, CA XN, XH, CA CA CA, CT CA, CT 277 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH, CA XN, XH, CA, CT XN, XH CA CA CA CA CA, CT CA MT7 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA CA, SC CA TT3 XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH CA CA CA, CT CA, CT - 347 XN, XH XN, XH XN, XH, CT XN, XH XN, XH CA CA CA, CT, SC CA - 480 XN, XH XN, XH, CA XN, XH, CA CA CA CA CA, SC CA CA, SC DT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH CA CA XN, XH, CA CA, CT, SC CA, CT CA, CT Contempo Series 245 continued Watts 05S 07S 07M 10S 10M 13S 14S 15S 15M 17M 20S 25S 25M 31S 40S 40M MT1 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA CA, SC CA MT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA CA, SC CA 5T4 CA CA CA CA TwistPack Series TWT Wattage 05S 07S 07M 10S 10M 15S 15M 17M 20S 25S 25M 120 RN,RH RN, RH, CA, CT XN, XH RN, RH, CA, CT XN, XH, CA RN, RH, CA, CT XN, XH CA CA XN, XH, CA CA 208 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA CA 240 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA RN, RH, CA XN, XH, CA CA 277 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH, CA XN, XH, CA, CT XN, XH CA CA CA CA TT3 XN, XH, CT XN, XH XN, XH, CT XN, XH XN, XH CA CA CA, CT CA, CT 5T4 CA CA 347 XN, XH XN, XH XN, XH, CT XN, XH XN, XH CA CA CA, CT, SC 480 XN, XH XN, XH, CA XN, XH, CA CA CA CA CA, SC DT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH CA CA XN, XH, CA CA, CT, SC MT1 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA CA, SC TwistPack Series TWT continued Wattage 05S 07S 07M 10S 10M 15S 15M 17M 20S 25S 25M MT2 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA CA, SC MT7 XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH XN, XH, CA, CT XN, XH CA CA CA CA, SC Product Guide 105 NOTES 106 Product Guide For photometric information, visit our website, www.americanelectriclighting.com SECURITY LIGHTING NEMA Head Series 11 ...........................................108 NEMA Head Package Series 11 PKG .................110 Series 11 “L” Package...........................................112 Dusk To Dawn Series DTD....................................114 Series 165 ................................................................116 Accessories ............................................................118 Ballast Matrices .....................................................119 American Electric Lighting® 107 NEMA Head Series 11 Security Lighting 50-250W HPS, 100-175W MH P R O D U C T O V E R V I E W Features: Die-cast aluminum head meets NEMA dimension standards For quick easy installation of mast arm, a cast-in external slipfitter is used for a secure mounting Available in a variety of IES light distribution patterns , including full cutoff Tools are not required to install reflector and refractor Tool-less adjustable photocontrol mount Available for arm size 1-1/4" (standard) and 2" fitter Open bottom acrylic, polycarbonate, or glass All electrical components warranted by American Electric Lighting's 6-year guarantee Suitable for -30°C MH / -40°C HPS Complies with ANSI: C136.2, C136.6, C136.10 Applications: Security areas Storage yards Loading areas Receiving areas DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 11 10S RN 120 R5 BA SW5 11 10S RN 120 RO LO 11 15S RN 120 R5 BA SW5 11 15S RN 120 RO LO 11 10M XN 120 R5 BA MDO Approx. Wt. = 16 lbs. Vented Bottom Acrylic (VBA) Approx. Wt. = 16 lbs. 108 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Full Cutoff (FC) NEMA Head Series 11 Security Lighting 50-250W HPS, 100-175W MH O R D E R I N G I N F O R M AT I O N Example: 1 1 1 0 S R N 1 2 0 R 5 B A Wattage / Source Series 11 NEMA Head 05 07 10 15 17 25 50W 70W 100W 150W 175W 250W Voltage Ballast RN Reactor Normal Power Factor XN High Reactance / Lag Normal Power Factor CA CWA, Auto Reg. S HPS M MH Refer to the ballast matrix on page 119 for compatibility. 120 208 240 277 MT1 MT2 MT7 120V 208V 240V 277V 120V Multi-tap 240V Multi-tap 277V Multi-tap Distribution R2 R3 R5 RO Type II Type III Type V No Optics (not for MH) Optics LO BA BP FC BG VBA Options 2 Mast Arm M4 24" Arm M3 30" Arm Photocontrol Receptacle (blank) Standard 3 NR No Photocontrol Receptacle Supply Wire4 SW5 Pre-wire 5' PW5 Wired to Terminal Block 5' (For more options see page 118) Starter5 (blank) Open Board Standard EC Encapsulated Starter Fitter Size (blank) 1-1/4“ Fitter H2 2” Fitter set for 1-1/4“ Lamp LC Lamp Included, Clear LD Lamp Included, Deluxe/Coated Misc. PC NL LA SH MDO Photocontrol Included per Voltage Specified NEMA Label Lightning Arrestor Shorting Cap5 Medium Base Socket, Open Rated (100W and 150W MH only)7 Less Optics Open Bottom Acrylic6 Open Bottom Polycarbonate Full Cutoff1,7,8 Open Bottom Glass6 Vented Bottom Acrylic (required for mogul base MH lamp only) Notes: 1 2 3 4 5 6 7 8 Available in R5 distribution only Available in 1 ¼" aluminum pipe only Not available with PC or DPC option Standard with #14 copper solid, black-white, THHN HPS only MH version requires open rated socket (MDO) Requires open rated lamp Nighttime FriendlyTM optic Product Guide 109 NEMA Head Package Series 11 PKG Security Lighting 50-250W HPS, 100-175W MH P R O D U C T O V E R V I E W Features: Die-cast aluminum head meets NEMA dimension standards For quick easy installation of mast arm, a cast-in external slipfitter is used for a secure mounting Available in a variety of IES light distributions patterns including full cutoff Tools are not required to install reflector and refractor Includes 24”, 1-1/4” diameter mast arm with welded brackets, lamp, photocontrol, 5’ of supply wire, and hardware All electrical components warranted by American Electric Lighting's 6-year guarantee All components in single carton Open bottom acrylic, polycarbonate, or glass Suitable for -30°C MH / -40°C HPS Complies with ANSI: C136.2, C136.6, C136.10 Applications: PREFERRED SELECTION CATALOG NUMBERS Security areas Storage yards Loading areas Receiving areas 11PKG 10S RN 120 R5 BA EC 11PKG 15S RN 120 R5 BA EC 11PKG 10M XN 120 R5 BA MDO DIMENSIONS Vented Bottom Acrylic (VBA) Note: Package includes welded bracket, 24” mast arm 1-1/4” diameter, lamp, photocontrol, 5’ of supply wire and hardware. Approx. Wt. = 18 lbs. 110 Product Guide Full Cutoff (FC) For photometric information, visit our website, www.americanelectriclighting.com NEMA Head Package Series 11 PKG Security Lighting 50-250W HPS, 100-175W MH O R D E R I N G I N F O R M AT I O N Example: 1 1 P K G 1 5 S R N 1 2 0 R 5 B A E C Wattage / Source Series 11PKG NEMA Head Package 05 07 10 15 17 25 50W 70W 100W 150W 175W 250W S HPS M MH Ballast CA CWA, Auto Reg.1 RN Reactor/Normal Power Factor XN High Reactance/Lag Normal Power Factor Refer to the ballast matrix on page 119 for compatibility. Voltage 120 208 240 277 MT1 MT8 MT2 MT7 Optics Distribution 120V 208V 240V 277V 120V Multi-tap 208V Multi-tap 240V Multi-tap 277V Multi-tap R2 Type II R3 Type III R5 Type V BA Open Bottom Acrylic3 BP Open Bottom Polycarbonate FC Full Cutoff2,3,6 BG Open Bottom Glass VBA Vented Bottom Acrylic (required for MH) Options Photocontrol (per voltage specified) (blank) Photocontrol (standard) Starter4 (blank) Open Board (standard) EC Encapsulated Starter Lamp (blank) LD Misc. NL MDO Notes: Lamp Included, Clear Lamp Included, Deluxe/Coated NEMA Label Medium Base Socket, Open Rated (100W and 150W MH only)5 1 2 3 4 5 6 Available in 175W MH only Available in R5 distribution only MH version requires open rated lamp Available in HPS only Open rated lamp supplied Nighttime FriendlyTM optic Product Guide 111 Series 11 “L” Package Security Lighting 50-150W HPS P R O D U C T O V E R V I E W Features: Die-cast aluminum head meets NEMA dimension standards For quick easy installation of mast arm, a cast-in external slipfitter is used for a secure mounting Includes 18” mast arm, lamp, photocontrol, pre-wire, and hardware All components in single carton Open bottom acrylic Suitable for -30°C MH / -40°C HPS Complies with ANSI: C136.2, C136.6, C136.10 UL Listed for wet locations Applications: Rural areas Area lighting Small businesses DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 11L 10S RN 120 R5 BA 11L 15S RN 120 R5 BA Note: Package includes 18” mast arm, lamp, photocontrol, pre-wire, and hardware. Approx. Wt. = 18 lbs. 112 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Series 11 “L” Package Security Lighting 50-150W HPS O R D E R I N G I N F O R M AT I O N Example: 1 1 L 1 5 S X N 1 2 0 R 5 B A Wattage / Source Series 05 07 10 15 11L Security Package 50W 70W 100W 150W S HPS Refer to the ballast matrix on page 119 for compatibility. Ballast RN Reactor Normal Power Factor XN High Reactance / Lag Normal Power Factor Voltage 120 208 240 277 MT1 MT2 MT7 Optics Distribution 120V R5 Type V 208V 240V 277V 120V Multi-tap 240V Multi-tap 277V Multi-tap BA Open Bottom Acrylic Options Photocontrol (per voltage specified) (blank) Photocontrol (standard) Notes: 1 Available in 1-1/4” aluminum pipe only Mast Arm WA Welded Arm (24” mast arm)1 Listing (blank) CS Package includes 18” mast arm, lamp, photocontrol, pre-wire and hardware UL Listed (standard) CSA Certified Product Guide 113 Dusk to Dawn Series DTD Security Lighting 150-400W HPS, 175-400W MH P R O D U C T O V E R V I E W Features: Ballast is completely enclosed in arm, but is readily accessible All components in single carton Refractor available in open bottom acrylic, or polycarbonate All electrical components warranted by American Electric Lighting's 6-year guarantee Suitable for -30°C MH & / -40°C HPS Complies with ANSI: C136.2, C136.10 Applications: Rural areas Small businesses Storage lots DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS DTD 15S RH 120 R5 BA CS LC PC NL DTD 25S XN 120 R5 BA CS LC PC Approx. Wt. = 23 lbs. 114 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Dusk to Dawn Series DTD Security Lighting 150-400W HPS, 175-400W MH O R D E R I N G I N F O R M AT I O N Example: D T D 1 5 S R H 1 2 0 R 5 B A Wattage / Source Series DTD Dusk to Dawn 15 17 25 40 150W 175W 250W 400W Voltage Ballast S HPS M MH1 Refer to the ballast matrix on page 119 for compatibility. RN RH CA CT XN Reactor Normal Power Factor Reactor High Power Factor CWA Auto Reg CWI High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor 120 240 277 347 480 MT1 MT2 MT7 TT3 120V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Distribution R5 Type V Optics BA Open Bottom Acrylic Options Standard Listing (blank) No Listing CS CSA Certified Photocontrol NR No Photocontrol Receptacle2 Lamp LC LD Misc PC NL SH Notes: Photocontrol Included per Voltage Specified NEMA Label Shorting Cap 1 2 Requires open rated lamp Not available with PC or SH option Lamp Included, Clear Lamp Included, Deluxe/Coated Product Guide 115 Series 165 Security Lighting – Ballast-In-Arm 50-400W HPS, 175-400W MH P R O D U C T O V E R V I E W Features: One piece die cast aluminum head and arm configuration for long-life stability and performance Optical assembly utilizes dual latch mounting for quick, easy and secure installation Electrical components mounted to power door for installation and maintenance convenience Gray polyester powder coated housing finish is standard Refractors available in open bottom acrylic, polycarbonate and glass NEMA Label standard Open board starter standard on HPS units Suitable for -30°C MH / -40°C HPS Complies with ANSI: C136.2, C136.10, C136.15, C136.6 6’ of supply wire and hardware included Applications: Parking lots Roadways Commercial environments Office communities DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 165 25S XN 120 R5 BA LC PC 165 20S XN 120 R5 BA PJ0 LC 165 40S CA MT1 R5 BG LC PC 165 40M SC MT1 R5 BG LC PC Approx. Wt. = 35 lbs. 116 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Series 165 Security Lighting – Ballast-In-Arm 50-400W HPS, 175-400W MH O R D E R I N G I N F O R M AT I O N Example: 1 6 5 4 0 S C A 1 2 0 R 5 B A L C P C Wattage / Source Series 165 Ballast-in Arm 05 07 10 15 17 20 25 40 S HPS M MH 50W 70W 100W 150W 175W 200W 250W 400W Voltage Ballast Refer to the ballast matrix on page 119 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Auto Reg CT CWI SC SCWA MR Mag Reg 120 208 240 277 480 MT1 MT2 MT7 120V 208V 240V 277V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Distribution R3 Area Type III R5 Area Type V Optics BA Open Bottom Acrylic BP Open Bottom Polycarbonate BG Open Bottom Glass1 Options Terminal Block (blank) Hard Wired (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position)2 Fusing3 SF DF Single Fuse (120, 277V) Double Fuse (208, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle4 Starter (blank) EC Open Board (standard) Encapsulated Starter5 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Misc. PC TL SS Notes: 1 2 3 4 5 Not available in R4 distribution T3 option only available with 240, 480, DT2, DT4, MT2 Not available with MT PC option not available with NR option Available in HPS only Photocontrol Included per Voltage Specified4 Tool-less Entry Stainless Steel Hardware Product Guide 117 Accessories P S Pre-wired to terminal block Supply wire included in carton WIRE SIZE AND SPECIFICATION W I R E A B C D E F G H I J K L W M N #10 CU Solid B/W #10 CU Solid B/B #10 CU Solid B/B/W #10 CU Stranded B/W #10 CU Stranded B/B #10 CU Stranded B/B/W #12 CU Solid B/W #12 CU Solid B/B #12 CU Solid B/B/WD #12 CU Stranded B/W #12 CU Stranded B/B #12 CU Stranded B/B/W #14 CU Solid B/W #14 CU Solid B/B #14 CU Solid B/B/W LENGTH P R E - S U P P LY 4 5 6 8 0 4’ 5’ 6’ 8’ 10’ Examples SW5 = 5’ of #14 CU. Solid, B/W wire supplied in carton PW5 = 5’ of #14 CU. Solid, B/W pre-wired to terminal block PD0 = 10’ of #10 CU. Stranded, B/W pre-wire to terminal block 118 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Security Lighting B A L L A S T M AT R I C E S Nema Head 11 Watts 05S 07S 10S 10M 15S 17M 25S 120 RN RN RN XN RN CA XN 208 XN XN XN XN CA - 240 XN XN XN XN CA RN 277 XN XN XN XN CA - MT1 XN XN XN XN CA - MT2 XN XN XN XN CA - MT7 XN XN XN XN CA - Nema Head Package Series 11PKG Watts 05S 07S 10S 10M 15S 17M 25S 120 RN RN RN XN RN CA XN 208 XN XN XN XN CA - 240 XN XN XN XN CA RN 277 XN XN XN XN XN CA - MT1 XN XN XN XN CA - MT2 XN XN XN XN CA - MT7 XN XN XN XN CA - 240 XN XN XN XN 277 XN XN XN XN MT1 XN XN XN XN MT2 XN XN XN XN MT7 XN XN XN XN Series 11L Package Watts 05S 07S 10S 15S 120 RN RN RN RN 208 XN XN XN XN TT3 XN XN XN Dusk To Dawn Watts 15S 17M 25S 40S 120 RN,RH,CA,CT,MR CA XH,XN,CA,CT,MR CA,CT,XN,XH 240 CA,CT,XN,XH,MR CA RN,RH,CA,CT,MR RH,RN,CA,CT 277 XN,XH,CA CA CA,CT CA,CT 480 CA,MR CA CA,MR CA MT1 XN,XH,CA,CT CA CA,CT CA,CT MT2 XN,XH,CA,CT CA CA,CT CA,CT MT7 XN,XH,CA,CT CA CA,CT CA,CT TT3 XN,XH CA CA Series 165 Watts 05S 07S 10S 15S 17M 25M 20S 25S 40S 40M 120 RH,RN RH,CA,CT,RN,MR CA,CT,MR,RH,RN RN,RH,CA,CT,MR CA CA,CT,SC CA, CT, XN, XH MR XH,XN,CA,CT CA,CT,XN,XH CA 208 XH,XN XH,CA,CT,XN XH,CA,CT,XN CA,CT,XN,XH CA CA,CT,SC CA, CT CA,CT CA,CT CA 240 XH,XN XH,CA,CT,MR,XN XH,CA,CT,MR,XN CA,CT,XN,XH,MR CA CA,CT,SC CA,CT,RN,RH,MR RN,RH,CA,CT RH,RN,CA,CT CA 277 XH,XN XH,CA,XN CA,XH,XN XN,XH,CA CA CA,SC CA,CT,MR CA,CT CA,CT CA 480 MR CA CA,MR CA CA,CT CA,CT,MR CA CA CA MT1 XH,XN XH,XN,CA CA,XN,XH XN,XH,CA,CT CA CA,SC CT,CA CA,CT CA,CT CA,SC MT2 XN,XH XH,XN,CA, CA,XN,XH XN,XH,CA,CT CA CA,SC CT,CA CA,CT CA,CT CA MT7 XN,XH XH,XN,CA, CA,XN,XH XN,XH,CA,CT CA CA,SC CT,CA CA,CT CA,CT CA Product Guide 119 NOTES 120 Product Guide For photometric information, visit our website, www.americanelectriclighting.com AREA LIGHTING ASA ........................................................................122 PES ........................................................................124 PEM ........................................................................126 VMR ........................................................................128 VLR ........................................................................130 AVL-BIA ................................................................132 AVL ..........................................................................134 LuxMaster® Luminaire Series 53 ......................136 LuxMaster® Luminaire Series 153 ....................138 LuxMaster® Classic Series LS............................140 LuxMaster® Classic Series LM ..........................142 Accessories ..........................................................144 Ballast Matrices....................................................148 American Electric Lighting® 121 ASA Area Lighting 70-400W HPS, 70-400W MH P R O D U C T O V E R V I E W Features: NEW Superior electrical and thermal performance backed by AEL’s 6-year electrical warranty Industry leading Dark To LightTM electronic photocontrol included with PC option Stainless steel external hardware available Impact resistant flat glass Rugged die-cast aluminum enclosure, polyester powder coat paint finish Rotatable and interchangeable R2, R3 and R5 hydroformed optics, segmented forward throw reflector with R4 distribution Aluminum extruded arms available in 4” or 9” mounting for square, round or wood poles External horizontal mast arm fitter mounting option Tool-less entry latching option Applications: Tool-less PEC receptacle, standard Parking lots Roadways Commercial environments Office communities Housing sealed with high temperature silicone gasketing Terminal block and phosphor bronze PEC receptacle contacts, standard PREFERRED SELECTION CATALOG NUMBERS DIMENSIONS ASA 24S CA MT7 R2 SP4 SH ASA 40M SC MT1 R3 SP4 LC PC ASA 40M SC MT1 R5 SP4 LC PC Effective Projected Area (EPA) The EPA for the ASA is 1.7 sq. ft. with a 4”arm; 1.8 sq. ft. with a 9” arm Approx. Wt = 37 lbs. 122 Product Guide For photometric information, visit our website, www.americanelectriclighting.com ASA Area Lighting 70-400W HPS, 70-400W MH O R D E R I N G I N F O R M AT I O N Example: A S A 4 0 M C A M T 1 R 3 S P 4 L C P C Wattage / Source Series ASA Architectural Site Area Light S HPS 70W M MH 100W 150W 175W 200W 250W 310W 400W 250/400W Wired 250W 24 250/400W Wired 400W 07 10 15 17 20 25 31 40 23 RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal XH High Reactance (Lag) High CA CWA (Auto Reg) CT CWI SC SCWA Distribution Voltage Ballast 120 208 240 277 347 480 MT1 MT2 MT7 TT3 5T4 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V 5-Tap Wired 480V R2 Area Type II R3 Area Type III R4 Type IV Forward Throw, Sharp Cutoff1 R5 Type V, Symmetric Mounting (blank) SP4 SP9 RP4 RP9 WW4 WW9 Refer to the ballast matrix on page 148 for compatibility. Less Mounting8 Square, 4” Square, 9” Round, 4” Round, 9” Wood, 4” Wood, 9” Shipped Separate RKASA EF BZ External Mast Arm Mount Options Paint2 (blank) BK GY WH Bronze (standard) Black Gray White Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position)3 Listing (blank) CS XL Lamp Included, Clear Lamp Included, Deluxe/Coated Fusing6 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Misc. PC TL SS UL Listed (standard) CSA Certified No Listing Notes: Lamp LC LD 5H NL SH Photocontrol Included per Voltage Specified Tool-less Entry Stainless Steel Fasteners (external) 50 Hertz Ballast Frequency7 NEMA Label Shorting Cap 1 2 3 4 5 6 7 8 Segmented reflector, not rotatable Other colors available, please contact your local American Electric Lighting representative Not available for 120V fixtures PC & SH not available with NR option HPS only Not available in MT or TT voltages Limited availability, please contact your local American Electric Lighting representative Order less mounting for mast arm mount Photocontrol Receptacle (blank) Photocontrol Receptacle (standard) NR No Photocontrol Receptacle4 Starter5 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Board Plug-in Product Guide 123 Available Summer 2008 PES Area Lighting 70-150W HPS, 100-250W MH P R O D U C T O V E R V I E W Features: NEW Rugged, heavy-gauge, premium extruded aluminum housing Square shape, seam-welded and internally sealed for weathertight integrity Standard finish is dark bronze corrosion resistant polyester powder Anodized, segmented reflectors for uniformity and control Reflectors are tool-less, rotatable and interchangeable 3 cutoff distributions available, R2, R3 and FT Natural anodized, extruded aluminum door frame sealed to housing by silicone closed-cell gasket. Can be hinged from any of the four sides Lens is .125” thick, impact-resistant tempered glass Rugged die-cast aluminum enclosure, polyester powder coat paint finish Extruded 4” aluminum arm for square pole mounting is standard, optional mountings available Applications: High reactance, high power factor for 150W and below. Removable power tray and positive-locking disconnect plug Parking lots Street lighting Parking areas Medium-base socket for 150W MH and below. Mogul-base porcelain socket with copper alloy, nickel-plated screw shell and center contact Terminal block and phosphor bronze PEC receptacle contacts, standard UL Listed 1500W-600V. 4KV pulse rated UL Listed, standard. CSA Certified or NOM Certified. UL Listed for wet locations DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS PES 10M XH MT1 FT SP4 LC PC PES 10S CA MT1 R3 SP9 LC PC Effective Projected Area (EPA) The EPA for the PES is 1.3 sq. ft. Approx. Wt = 26.6 lbs. 124 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Available Summer 2008 PES Area Lighting 70-150W HPS, 100-250W MH O R D E R I N G I N F O R M AT I O N Example: P E S 1 5 S R N 1 2 0 Series Wattage / Source PES Premium Small S HPS 07 70W M MH 10 100W 13 100/150W wired 100 14 100/150W wired 150 15 150W 17 175W 25 250W1 RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal XH High Reactance (Lag) High CA CWA (Auto Reg) Distribution Voltage Ballast 120 208 240 277 347 480 MT1 MT2 MT7 TT3 R2 SP9 PC 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V R2 Roadway Type II R3 Roadway Type III FT Forward Throw, Sharp Cutoff Refer to optical matrix below for compatibility Refer to the ballast matrix on page 148 for compatibility. Mounting (blank) SP4 SP9 RP4 RP9 WW4 WW9 Less Bracket for Mast Arm Mount Square, 4” (standard) Square, 9” Round, 4” Round, 9” Wood, 4” Wood, 9” Shipped Separate RKPES EF BZ External Mast Arm Mount Options Paint (blank) BK WH Bronze (standard) Black White Terminal Block (blank) Wire Nuts (standard) TB Wired to L1 & N Positions T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L3 Position) Listing (blank) CS XL Starter (blank) EC OP Lamp LC Fusing SF DF Misc. PC UL Listed (standard) CUL or CSA Listed No Listing Photocontrol Receptacle (blank) Photocontrol Receptacle (standard) NR No Photocontrol Receptacle TL 5H SH NL Notes: Open Board (standard) Encapsulated Plug-in Open Board Plug-in 1 MA only Lamp Included, Clear Single Fuse (120, 277, 347V) Double Fuse (208, 240, 480V) Photocontrol Included per Voltage Specified Tool-less Entry 50 Hertz Ballast Frequency Shorting Cap NEMA Label Optic Distribution 07S 10S 10M 15S 15M 17M 25M R2 N N N N N N N R3 N N N N N N N FT N N N N N N N Product Guide 125 Available Summer 2008 PEM Area Lighting 200-400W HPS, 250-400W MH P R O D U C T O V E R V I E W Features: NEW Rugged, heavy-gauge, premium extruded aluminum housing Square shape, seam-welded and internally sealed for weathertight integrity Standard finish is dark bronze corrosion resistant polyester powder Anodized, segmented reflectors for uniformity and control Reflectors are tool-less, rotatable and interchangeable 4 cutoff distributions available, R2, R3, R5 and FT Natural anodized, extruded aluminum door frame sealed to housing by silicone closed-cell gasket. Can be hinged from any of the four sides Lens is .125” thick, impact-resistant tempered glass Rugged die-cast aluminum enclosure, polyester powder coat paint finish Extruded 4” aluminum arm for square pole mounting is standard, optional mountings available Applications: Parking lots Roadways Commercial environments Office communities Constant wattage autotransformer for 250W and above. Removable power tray and positive-locking disconnect plug Mogul-base porcelain socket with copper alloy, nickel-plated screw shell and center contact Tool-less PEC receptacle, standard Terminal block and phosphor bronze PEC receptacle contacts, standard UL Listed 1500W-600V. 4KV pulse rated UL Listed, standard. CSA Certified or NOM Certified. UL Listed for wet locations DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS PEM 40M SC MT1 R5 SP9 LC PC PEM 40M SC MT1 FT SP9 LC PC Effective Projected Area (EPA) The EPA for the PEM is 1.9 sq. ft. Approx. Wt = 39.9 lbs. 126 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Available Summer 2008 PEM Area Lighting 200-400W HPS, 250-400W MH O R D E R I N G I N F O R M AT I O N Example: P E M 4 0 M C A M T 1 R 3 S P 4 L C P C Wattage / Source Series PEM Premium Medium 20 25 31 32 35 40 200W 250W 310W 320W 350W 400W S HPS M MH Refer to the ballast matrix on page 149 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal XH High Reactance (Lag) High CA CWA (Auto Reg) SC SCWA Distribution Voltage Ballast 120 208 240 277 347 480 MT1 MT2 MT7 TT3 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V R2 R3 R5 FT Roadway Type II Roadway Type III Type V, Square Forward Throw, Sharp Cutoff Refer to optical matrix below for compatibility Mounting (blank) SP4 SP9 RP4 RP9 WW4 WW9 Less Bracket for Mast Arm Mount Square, 4” Square, 9” Round, 4” Round, 9” Wood, 4” Wood, 9” Shipped Separate RKPEM EF BZ External Mast Arm Mount Options Paint (blank) BK WH Bronze (standard) Black White Terminal Block (blank) Wire Nuts (standard) TB Wired to L1 & N Positions T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L3 Position) Listing (blank) CS XL Starter (blank) EC OP Lamp LC Fusing SF DF Misc. PC UL Listed (standard) CUL or CSA Listed No Listing Photocontrol Receptacle (blank) Photocontrol Receptacle (standard) NR No Photocontrol Receptacle TL 5H SH Open Board (standard) Encapsulated Plug-in Open Board Plug-in Lamp Included, Clear Single Fuse (120, 277, 347V) Double Fuse (208, 240, 480V) Photocontrol Included per Voltage Specified Tool-less Entry 50 Hertz Ballast Frequency Shorting Cap Optic Distribution 20S 25S 25M 31S 32M 35M 40S 40M R2 N N N N N N N N R3 N N N N N N N N R5 N N N N N N N N FT N N N N N N N N Product Guide 127 Available Summer 2008 VMR Area Lighting 70-150W HPS, 50-200W MH P R O D U C T O V E R V I E W Features: NEW Heavy-gauge, spun aluminum housing Integral structural support plate for mounting arm and electrical components ensures rigidity and strength Hinged aluminum door frame incorporates stainless steel hardware Continuous silicone gasketing surrounds lens for weather-tight seal Thermal, shock-resistant tempered flat or drop glass lens Standard finish is dark bronze, electrostatically applied powder paint. Linear embossed accent reveals are standard. Additional architectural colors and striping are available Most flat lens configurations meet full-cutoff criteria. Vertical-lamp reflectors are one-piece spun and formed anodized aluminum High performance segmented aluminum reflectors are used with horizontal lamps. They are rotatable and interchangeable Applications: High reactance, high power factor for 50-150W. Constant wattage autotransformer for 175W. Metal halide 150W and below are standard with pulse-start ignitor technology; super SCWA pulse-start ballast required for 200W Parking lots Street lighting Parking areas Porcelain, horizontally mounted medium base socket with copper alloy, nickelplated screw shell and center contact Arms are available for use with various poles, wall mounting and unique configurations. 4” aluminum fitter for open-top pole is available Listed and labeled to UL standards for 25ºC ambient and wet locations. Listed and labeled to CSA standards. NOM Certified DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS VMR 10M XH MT1 SM DG P9 LC PC TL VMR 10M XH MT1 SM FG P9 LC PC TL VMR 10S CA MT1 SM FG P9 LC PC TL 11.55 (293) Effective Projected Area (EPA) The EPA for the VMR Arm Mount is 1.8 sq. ft., Approx. Wt = 35 lbs. The EPA for the VMR Post-top is 1.9 sq. ft. 128 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Available Summer 2008 VMR Area Lighting 70-150W HPS, 50-200W MH O R D E R I N G I N F O R M AT I O N Example: V M R 1 7 M C A 1 2 0 S M F G S 9 L C Series VMR Vertical Medium Round Wattage / Source 05 07 10 15 17 20 50W 70W 100W 150W 175W 200W S HPS1 M MH Distribution Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor Refer to the ballast matrix on XH High Reactance / page 149 for compatibility. Lag High Power Factor CA CWA SC SCWA2 CT CWI 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V 5T4 5-tap Wired 480V Vertical Lamp AM Asymmetric SM Symmetric Horizontal Lamp R2 Area Type II R3 Area Type III FT Forward Throw, Sharp Cutoff R5 Area Type V Bronze (standard) Black Gray White Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Listing (blank) CS UL Listed (standard) CSA Certified Fusing5 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle6 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Starter7 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Misc. A4 PC TL SS 5H NL SH 4-7/8” Hole Spacing on Housing and Arm Photocontrol Included per Voltage Specified6 Tool-less Entry Stainless Steel Fasteners (external) 50 Hertz Ballast Cycle8 NEMA Label on Housing Shorting Cap6 Accessories (shipped separately) VMREHS U Field Installable External HS Shield Universal Tenon Adapter FG Flat Glass Clear Tempered9 DG Drop Glass Clear Tempered Refer to optical matrix below for compatibility Mounting3 S9 P9 S2 P2 WP WB EF P3 P7 S3 S7 PT4 Options Paint4 (blank) BK GY WH Optics Square Pole, 9” Arm Round Pole, 9” Arm Square Pole, 12” Arm Round Pole, 12” Arm Wood Pole or Wall, 12” Arm Wall Bracket, 12” Arm External Mast Arm Fitter Round Pole Fitter, 2-3/8” OD Round Pole Fitter, 2-7/8” OD Square Pole Fitter, 2-3/8” OD Square Pole Fitter, 2-7/8” OD Spider Mount, 4” OD, Open Top Pole Notes: 1 2 3 4 5 6 7 8 9 Not available with SCWA Pulse Start Metal Halide only Standard arm-hole bolt spacing is 4-1/4”. For 4-7/8” spacing, order “A4” option. Other colors available, please contact your local American Electric Lighting representative Voids UL/CSA Listing, not available with MT, TT, and DT voltages PC & SH not available with NR option HPS only, 400W max Limited availability, please contact your local American Electric Lighting representative Nighttime FriendlyTM optic Optic Distribution 07S 10S 10M 15S 15M 17M 20M AM FG SM FG FT FG R2 FG R3 FG R5 FG AM DG SM DG FT DG R2DG R3DG N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N Product Guide 129 Available Summer 2008 VLR Area Lighting 250-1000W HPS, 175-1000W MH P R O D U C T O V E R V I E W Features: NEW Heavy-gauge, spun aluminum housing Integral structural support plate for mounting arm and electrical components ensures rigidity and strength Hinged aluminum door frame incorporates stainless steel hardware Continuous silicone gasketing surrounds lens for weather-tight seal Thermal, shock-resistant tempered flat or drop glass lens Standard finish is dark bronze, electrostatically applied powder paint. Linear embossed accent reveals are standard. Additional architectural colors and striping are available Most flat lens configurations meet full-cutoff criteria. Vertical-lamp reflectors are one-piece spun and formed anodized aluminum High performance segmented aluminum reflectors are used with horizontal lamps. They are rotatable and interchangeable Applications: Mogul base porcelain socket with copper alloy, nickel-plated screw shell and center contact Parking lots Street lighting Parking areas Reflectors are rotatable and interchangeable Arms are available for use with various pole and wall mounting. 4” aluminum fitter for open-top pole is available Listed and labeled to UL standards for 25ºC ambient and wet locations. Listed and labeled to CSA standards. NOM Certified DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS VLR X1M CA MT1 SM FG P2 LC TL VLR X1M CA MT1 SM DG P2 LC TL VLR X1M SC MT7 SM FG P2 LC TL Effective Projected Area (EPA) The EPA for the PSE is 1.3 sq. ft. Approx. Wt = 26.6 lbs. 130 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Available Summer 2008 VLR Area Lighting 250-1000W HPS, 175-1000W MH O R D E R I N G I N F O R M AT I O N Example: V L R 1 7 5 M C A 1 2 0 A M F G S 9 P C Wattage / Source Series VLR Vertical Large Round 17 25 32 35 40 X1 175W 250W 320W 350W 400W 1000W Voltage Distribution Optics 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V 5T4 5-tap wired 480V Vertical Lamp AM Asymmetric SM Symmetric FV Forward Throw FG Flat Glass Clear Tempered12 DG Drop Glass Clear Tempered Horizontal Lamp R2 Area Type II R3 Area Type III FT Forward Throw, Sharp Cutoff9 Refer to optical matrix below for compatibility Ballast S HPS1,11 M MH10 CA CWA SC SCWA2 CT CWI Refer to the ballast matrix on page 150 for compatibility. 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 S9 P9 S2 P2 WP WB EF P3 P7 S3 S7 PT4 Options Paint4 (blank) BK GY WH UP Bronze (standard) Black Gray White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Listing (blank) CS Fusing5 SF DF UL Listed (standard) CSA Certified Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Starter7 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Misc. A4 1 2 3 4 Accessories (shipped separately) VLREHS U Field installable external HS shield universal tenon adapter 9 10 11 TL SS 5H NL SH 5 6 7 8 12 Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle6 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Square Pole, 9” Arm Round Pole, 9” Arm Square Pole, 12” Arm Round Pole, 12” Arm Wood Pole or Wall, 12” Arm Wall Bracket, 12” Arm External Mast Arm Fitter Round Pole Fitter, 2-3/8” OD Round Pole Fitter, 2-7/8” OD Square Pole Fitter, 2-3/8” OD Square Pole Fitter, 2-7/8” OD Spider Mount, 4” OD, Open Top Pole Notes: 4-7/8” Hole Spacing on Housing and Arm Photocontrol Included per Voltage Specified6 Tool-less Entry Stainless Steel Fasteners (external) 50 Hertz Ballast Cycle8 NEMA Label on Housing Shorting Cap6 PC Mounting3 Not available with SCWA Pulse Start Metal Halide only Standard arm-hole bolt spacing is 4-1/4”. For 4-7/8” spacing, order “A4” option. Other colors available, please contact your local American Electric Lighting representative Voids UL/CSA Listing, not available with MT, TT, and DT voltages PC & SH not available with NR option HPS only, 400W max Limited availability, please contact your local American Electric Lighting representative Not available with PT4 option 1000W MH uses reduced jacketed lamp 1000W HPS uses reduced jacketed lamp for FG options Nighttime FriendlyTM optic Optic Distribution 25S 31S 40S X1S 17M 25M 32M 35M 40M X1M AM FG SM FG FV FG AM DG SM DG FV DG R2 FG R3 FG FT FG R2FG R3FG FT DG N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N - Product Guide 131 AVL BIA Area Lighting – Ballast-in-Arm 200-1000W HPS, 250-1000W MH P R O D U C T O V E R V I E W Features: NEW Separate compartments provide ease of installation (reduced weight of housing, short mounting bolts). Rugged heavy gauge aluminum housing is continuously seam welded for weathertight integrity Silicone gasket seals optical compartment from moisture, insects and dust Available in multiple mounting options to fit a variety of applications Choice of drop or flat lens to allow for full cutoff compliance Separate optical and electrical compartments provide lower internal temperatures extending fixture life Available in a variety of IES light distributions patterns 1000W MH designed around reduced jacket lamp Tool-less die-cast trigger latches Choice of bolt spacing for mounting arm (4-1/4” or 4-7/8”) Applications: Mogul base, E39, socket standard Parking lots Roadways Commercial environments Office communities All electrical components warranted by American Electric Lighting's 6-year guarantee Suitable for -30°C MH / -40°C HPS Ballast tray(s) installable or removable without tools (trigger latch and plug-in connections) DIMENSIONS AVL Drop Glass AVL Flat Glass Effective Projected Area (EPA) Single 4.4 sq. ft. 2 @ 180 8.42 sq. ft. 2 @ 90 7.8 sq. ft. 3 @ 90 11.82 sq. ft. 4 @ 90 13.52 sq. ft. 132 Product Guide Approximate Weight 99 lbs. 170 lbs. 170 lbs. 241 lbs. 312 lbs. For photometric information, visit our website, www.americanelectriclighting.com AVL-Ballast-in-Arm AVL BIA Area Lighting – Ballast-in-Arm 200-1000W HPS, 250-1000W MH O R D E R I N G I N F O R M AT I O N Example: A V L B I A 1 X M C A M T 1 S M D G 4 9 0 3 0 F T Wattage / Source Series AVL BIA AVL Ballast in Arm AVL LMS AVL Low Mast System 20 25 31 32 35 40 45 75 1X 200W 250W 310W 320W1 350W1 400W 450W1 750W 1000W1 Voltage Distribution Optics 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V Vertical Lamp AM Asymmetric SM Symmetric FV Forward Throw3 FG Flat Glass Clear Tempered8 DG Drop Glass Clear Tempered Ballast S HPS M MH CA CWA SC SCWA2 CT CWI Refer to the ballast matrix on page 150 for compatibility. 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 Horizontal Lamp R2 Area Type II R3 Area Type III Refer to optical matrix below for compatibility Mounting7 Units 1 2 3 4 Pre-Wire Length7 Degrees 90 180 *Number of Units and Degrees should be combined to form one number. Ex: 490 20FT 25FT 30FT 35FT 40FT 45FT 50FT 55FT 60FT Options Paint4 (blank) BK GY WH UP Bronze (standard) Black Gray White Unpainted Listing UL CS MX UL Listing CSA Certified NOM Listed Misc. PC SS NL SH 4D 5H Notes: Photocontrol Included per Voltage Specified Stainless Steel Fasteners (external) NEMA Label on Housing Shorting Cap6 4” OD Tenon 50 Hertz Ballast Cycle6 Accessories (shipped separately) AVLEHS U Field Installable External House Side Shield 1 2 3 4 5 6 7 8 Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle6 Reduced jacket lamp only Pulse Start Metal Halide only Available in drop glass only Other colors available, please contact your local American Electric Lighting representative PC & SH not available with NR option Limited availability, please contact your local American Electric Lighting representative Not required for LMS Nighttime FriendlyTM optic Optic Distribution Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated 25S 31S 40S X1S 25M 32M 35M 40M 1XM AM FG SM FG FV FG AM DG SM DG FV DG R2 FG R3 FG FT FG R2DG R3DG FT DG N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N - Product Guide 133 AVL Area Lighting 250-1000W HPS, 250-1000W MH P R O D U C T O V E R V I E W Features: Rugged heavy gauge aluminum housing is continuously seam welded for weathertight integrity Silicone gasket seals optical compartment from moisture, insects and dust Available in multiple mounting options to fit a variety of applications Choice of drop or flat lens to allow for full cutoff compliance Available in a variety of IES light distributions patterns 1000W MH designed around reduced jacket lamp Tool-less die-cast trigger latches Choice of bolt spacing for mounting arm (4-1/4” or 4-7/8”) Mogul base, E39, socket standard All electrical components warranted by American Electric Lighting's 6-year guarantee Suitable for -30°C MH / -40°C HPS Applications: Parking lots Roadways Commercial environments Office communities DIMENSIONS AVL Flat Glass PREFERRED SELECTION CATALOG NUMBERS AVL Drop Glass AVL 1XM CA MT7 SM DG S9 TL AVL 1XM SC MT1 SM DG S9 NR LC AVL 1XM CA MT1 SM DG P2 NR LC TL Effective Projected Area (EPA) The EPA for the AVL is 2.8 sq. ft. Approx. Wt = 53 lbs. 134 Product Guide For photometric information please visit our website: www.americanelectriclighting.com AVL Area Lighting 250-1000W HPS, 250-1000W MH O R D E R I N G I N F O R M AT I O N Example: A V L 1 X M C A M T 7 S M D G S 9 Wattage / Source Series AVL American Vertical Luminaire 25 31 32 35 40 45 75 1X 250W 310W 320W1 350W1 400W 450W1 750W 1000W1 Voltage Distribution Optics 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V 5T4 5-tap wired 480V Vertical Lamp AM Asymmetric SM Symmetric FV Forward Throw FG Flat Glass Clear Tempered9 DG Drop Glass Clear Tempered Ballast S HPS M MH CA CWA SC SCWA2 CT CWI Refer to the ballast matrix on page 150 for compatibility. 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 Horizontal Lamp R2 Area Type II R3 Area Type III FT Area Type IV Mounting3 S9 P9 S2 P2 WP WB EF P3 P7 S3 S7 PT4 Options Paint4 (blank) BK GY WH UP Bronze (standard) Black Gray White Unpainted Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Listing UL CS Fusing5 SF DF UL Listing CSA Certified Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle6 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe/Coated Starter7 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Misc. A4 PC TL SS 5H NL SH TL 4D 4-7/8” Hole Spacing on Housing and Arm Photocontrol Included per Voltage Specified6 Tool-less Entry Stainless Steel Fasteners (external) 50 Hertz Ballast Cycle8 NEMA Label on Housing Shorting Cap6 Trigger Latch 4” OD Tenon Accessories (shipped separately) AVLEHS U Field Installable External HS Shield Universal Tenon Adapter10 Refer to optical matrix below for compatibility Notes: 1 2 3 4 5 6 7 8 9 10 Square Pole, 9” Arm Round Pole, 9” Arm Square Pole, 12” Arm Round Pole, 12” Arm Wood Pole or Wall, 12” Arm Wall Bracket, 12” Arm External Mast Arm Fitter Round Pole Fitter, 2-3/8” OD Round Pole Fitter, 2-7/8” OD Square Pole Fitter, 2-3/8” OD Square Pole Fitter, 2-7/8” OD Spider Mount, 4” OD, Open Top Pole Reduced jacket lamp only for MH Pulse Start Metal Halide only Standard arm-hole bolt spacing is 4-1/4”. For 4-7/8” spacing, order “A4” option. Other colors available, please contact your local American Electric Lighting representative Voids UL/CSA Listing, not available with MT, TT, and DT voltages PC & SH not available with NR option HPS only, 400W max Limited availability, please contact your local American Electric Lighting representative Nighttime FriendlyTM optic See page 145 for options Optic Distribution 25S 31S 40S X1S 25M 32M 35M 40M 1XM AM FG SM FG FV FG AM DG SM DG FV DG R2 FG R3 FG FT FG R2DG R3DG FT DG N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N - Product Guide 135 LuxMaster® Series 53 Area Lighting 70-150W HPS, 175W MH P R O D U C T O V E R V I E W Features: Durable die-cast aluminum housing for long-life performance Optical assembly designed for maximum performance Removable ballast tray electrical system for installation and maintenance ease "Breathing Seal" developed by American Electric prevents contaminants from entering optical assembly for maximum efficiency Optics available in flat tempered glass, sag glass, drop acrylic and drop polycarbonate Available in a variety of IES light distributions patterns and cutoff classifications Standard product is designed to mount to pipe mast arm. Direct pole mount arms are available Applications: Arm ordered separate, see page 144 Parking lots Roadways Residential communities Commercial environments Office communities All electrical components warranted by American Electric Lighting's 6-year guarantee UL Listed Mogul base, E39, socket standard Suitable for -30°C MH / -40°C HPS Complies with ANSI: C136.2, C136.10, C136.14, C136.15 DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 53 10S CA MT1 R2 DA 53 15S CA MT1 R2 FG 53 10S RH 120 R3 FG Effective Projected Area (EPA) The EPA for the LuxMaster® Series 53 with refractor 1.4 sq. ft. Approx Wt = 30 lbs. 136 Product Guide Effective Projected Area (EPA) The EPA for the LuxMaster® Series 53 with flat lens is 1.1 sq. ft. For photometric information please visit our website: www.americanelectriclighting.com LuxMaster® Series 53 Area Lighting 70-150W HPS, 175W MH O R D E R I N G I N F O R M AT I O N Example: 5 3 1 5 S C A M T 1 R 3 F G L C P C 53 LuxMaster Shoebox S HPS M MH 07 70W 10 100W 13 100/150W wired 100 14 100/150W wired 150 15 150W 17 175W Voltage Ballast Wattage / Source Series Refer to the ballast matrix on page 151 for compatibility. RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Auto Reg MR Mag Reg (3 coil) CT CWI 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 DT4 Distribution R2 Roadway Type II 120V R3 Roadway Type III 208V 240V Refer to optical matrix 277V below for compatibility 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V Dual Tap 240/480 Wired 480V Optics DA Drop Acrylic Prismatic Refractor DP Drop Polycarbonate Prismatic Refractor FG Flat Glass Clear Tempered6 SG Sag Glass Refractor Options Mounting (blank) Internal fitter (1-1/4”) M2 Internal fitter (pre-set 2”) Paint1 (blank) BK GY WH Bronze (standard) Black Gray White Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Fusing2 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 Lamp LC LD Lamp Included, Clear Lamp Included, Deluxe Starter4 (blank) EC OP PS Open Board (standard) Encapsulated Plug-in Open Plug-in Protected/Auto Shutoff5 Listing (blank) CS UL Listed (standard) CSA Certified Misc. PC SS LA 5H NL SH HK Notes: 1 2 3 4 5 6 Other colors available, please contact your local American Electric Lighting representative Voids UL/CSA Certified Options and not available in MT, TT, and DT voltages PC, & SH not available with NR option HPS only Limited availability, please contact your local American Electric Lighting representative Nighttime FriendlyTM optic Photocontrol Included per Voltage Specified3 Stainless Steel Fasteners (external) Lightning Arrestor (Void UL/CSA Listed Options) 50 Hertz Ballast Cycle5 NEMA Label on Housing Shorting Cap3 Hinge Keeper Optic Distribution 05S 07S 10S 15S 17M R2 DA N N N N - R3 DA N N N N - R2 DP N N N N - R3 DP N N N N - R2 FG N N N N N R3 FG N N N N N R2 SG N N N N N R3 SG N N N N N Product Guide 137 LuxMaster® Luminaire Series 153 Area Lighting 200-400W HPS, 200-400W MH P R O D U C T O V E R V I E W Features: Die-cast aluminum housing for long-life performance Optical assembly designed for maximum performance Ballast tray electrical system for installation and maintenance ease "Breathing Seal" developed by American Electric preventing contaminants from entering optical assembly Optics available in flat tempered glass, sag glass, drop acrylic and drop polycarbonate Available in a variety of IES light distributions patterns Standard product is designed to mount to pipe mast arm. Direct pole mount arms are available Arm ordered separate, see page 144 UL Listed Applications: All electrical components warranted by American Electric Lighting's 6-year guarantee Parking lots Roadways Residential communities Commercial environments Office communities Mogul base, 539 socket std. Suitable for -30°C MH / -40°C HPS Complies with ANSI: C136.2, C136.10, C136.14, C136.15 DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 153 40M SC MT1 R3 SG 153 25S CA MT1 R3 FG 153 40S CA MT1 R3 FG 153-1-BZ Effective Projected Area (EPA) The EPA for the LuxMaster® HPS Luminaire Series 153 with flat lens is 2.1 sq. ft. Approx Wt = 45 lbs. 138 Product Guide The EPA for the LuxMaster® HPS Luminaire Series 153 with drop lens is 2.4 sq. ft. For photometric information please visit our website: www.americanelectriclighting.com LuxMaster® Luminaire Series 153 Area Lighting 200-400W HPS, 200-400W MH O R D E R I N G I N F O R M AT I O N Example: 1 5 3 2 5 S C A M T 1 R 3 F G L C E C P C Wattage / Source Series 153 LuxMaster Shoebox S HPS M MH 20 25 31 40 23 200W 250W 310W 400W 250/400W wired 250 24 250/400W wired 400 Refer to the ballast matrix on page 151 for compatibility. Distribution Voltage Ballast RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Auto Reg MR Mag Reg (3 coil) CT CWI SC SCWA 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 DT4 R2 Roadway Type II 120V R3 Roadway Type III 208V 240V Refer to optical matrix 277V below for compatibility 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V Dual Tap 240/480 Wired 480V Optics DA Drop Acrylic Prismatic Refractor DP Drop Polycarbonate Prismatic Refractor FG Flat Glass Clear Tempered6 SG Sag Glass Prismatic Refractor Options Mounting (blank) Internal fitter (1-1/4”) M2 Internal fitter (pre-set 2”) Paint1 (blank) BK GY WH Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle3 Lamp LC LD Notes: 1 2 Bronze (standard) Black Gray White Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Fusing2 SF DF Starter4 (blank) Open Board (standard) EC Encapsulated Plug-in OP Open Plug-in Lamp Included, Clear Lamp Included, Deluxe Listing (blank) CS Misc. PC SS LA 5H NL SH HK UL Listed (standard) CSA Certified 3 4 5 Photocontrol Included per Voltage Specified3 Stainless Steel Fasteners (external) Lightning Arrestor 50 Hertz Ballast Cycle5 NEMA Label on Housing Shorting Cap3 Hinge Keeper 6 Other colors available, please contact your local American Electric Lighting representative Voids UL/CSA listing, not available with MT, TT, and DT voltages PC, & SH not available with NR option HPS only Limited availability, please contact your local American Electric Lighting representative Nighttime FriendlyTM optic Optic Distribution 20S 25S 31S 40S 25M 40M R2 DA N N N N - R3 DA N N N N - R2 DP N N N N - R3 DP N N N N - R2 FG N N R3 FG N N N N - R2 SG N N N N - R3 SG N N N N N N * Requires use of ED28 lamp Product Guide 139 LuxMaster® Classic Series LS Area Lighting 70-150W HPS, 175W MH P R O D U C T O V E R V I E W Features: Rugged heavy gauge aluminum housing is continuously seam welded for weathertight integrity Multiple mounting options to fit a variety of applications Optical assembly designed for maximum performance Removable ballast tray electrical system for installation and maintenance ease Mogul base, E39 socket standard "Breathing Seal" developed by American Electric prevents contaminants from entering optical assembly for maximum efficiency Tempered flat glass lens standard, drop polycarbonate option available Available in a variety of IES full cutoff light distributions patterns All electrical components warranted by American Electric Lighting's 6-year guarantee Suitable for -30°C MH / -40°C HPS Applications: Parking lots Office complexes Security lighting Residential areas Commercial environments DIMENSIONS Effective Projected Area (EPA) The EPA for the LuxMaster Classic Luminaire, Series LS is 1.75 sq. ft. Approx Wt. = 20 lbs. 140 Product Guide For photometric information please visit our website: www.americanelectriclighting.com LuxMaster® Classic Series LS The following three separate components must be ordered: 1) BALLAST TRAY 2) HOUSING 3) MOUNTING Area Lighting 70-150W HPS, 175W MH Each Ships Separately O R D E R I N G 1) Ballast Tray Example: L S 1 5 S R H 1 2 0 R 3 Wattage / Source Series LS LuxMaster Shoebox, Small 07 10 15 17 I N F O R M AT I O N S HPS M MH 70W 100W 150W 175W RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Auto Reg CT CWI Refer to the ballast matrix on page 152 for compatibility. Distribution Voltage Ballast 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap WWired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V R2 Roadway Type II R3 Roadway Type III R5 Roadway Type V Options Fusing1 SF DF Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle2 O R D E R I N G 2) Housing Series LS LuxMaster Shoebox, Small I N F O R M AT I O N Example: L S 1 5 S R 3 P C H S G Options Wattage / Source 07 10 15 17 XX S HPS 70W M MH 100W 150W 175W No Ballast3 Paint4 (blank) BK GY WH Distribution R2 Roadway Type II R3 Roadway Type III R5 Roadway Type V Housing Misc. SS Bronze (standard) Black Gray White SH PC LC Photocontrol Receptacle (blank) NEMA Photocontrol Receptacle (standard) NR No Photocontrol Receptacle2 HSG Housing Unit Stainless Steel Fasteners (external) Shorting Cap2 Photocontrol Included per Voltage Specified2 Lamp Included, Clear O R D E R I N G I N F O R M AT I O N 3) Mounting Example: L S P 3 B Z Notes: Paint Mounting Series 1 LM LuxMaster Shoebox, Small P W K M Y T 1 2 Square Pole 12” Arm Wall Bracket 12” Arm Adjustable Knuckle External Fitter Yoke Mount Square Tenon Square Tenon 2 Arms 90° Square Tenon 2 Arms 180° 3 4 5 6 7 8 9 R Square Tenon 3 Arms 90° Square Tenon 4 Arms 90° Round Tenon Round Tenon 2 Arms 90° Round Tenon 2 Arms 180° Round Tenon 3 Arms 90° Round Tenon 3 Arms 120° Round Tenon 4 Arms 90° Paint4 BZ Bronze (standard) BK Black GY Gray WH White 2 3 4 Voids UL/CSA Certified Options and not available in MT, TT, and DT voltages PC, & SH not available with NR option NL not available Other colors available, please contact your local American Electric Lighting representative Product Guide 141 LuxMaster® Classic Series LM Area Lighting 200-400M HPS, 250-400W MH P R O D U C T O V E R V I E W Features: Rugged heavy gauge aluminum housing is continuously seam welded for weathertight integrity Multiple mounting options to fit a variety of applications Optical assembly designed for maximum performance Removable ballast tray electrical system for installation and maintenance ease Mogul base, E39 socket standard "Breathing Seal" developed by American Electric prevents contaminants from entering optical assembly for maximum efficiency Tempered flat glass lens standard, drop polycarbonate option available Available in a variety of IES full cutoff light distributions patterns All electrical components warranted by American Electric Lighting's 6-year guarantee Suitable for -30°C MH / -40°C HPS Applications: Office complexes Parking lots Residential areas Commercial environments Security lighting DIMENSIONS Effective Projected Area (EPA) The EPA for the LuxMaster Classic Luminaire, Series LM is 2.36 sq. ft. Approx Wt. = 45 lbs. 142 Product Guide For photometric information please visit our website: www.americanelectriclighting.com LuxMaster® Classic Series LM The following three separate components must be ordered: 1) BALLAST TRAY 2) HOUSING 3) MOUNTING Area Lighting 200-400M HPS, 250-400W MH Each Ships Separately O R D E R I N G 1) Ballast Tray Example: L M 2 0 S X H 1 2 0 R 3 Wattage / Source Series LM LuxMaster Shoebox, Medium I N F O R M AT I O N S HPS M MH 20 200W 25 250W 40 400W RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance / Lag Normal Power Factor XH High Reactance / Lag High Power Factor CA CWA Auto Reg CT CWI SC SCWA Refer to the ballast matrix on page 152 for compatibility. Distribution Voltage Ballast 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V O R D E R I N G LM LuxMaster Shoebox, Medium Options Fusing1 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 220, 240, 480V) Terminal Block (blank) Terminal Block (standard) T2 Wired to L1 & L2 Positions T3 3 Wire Operation (L1, N, L2 Position) Photocontrol Receptacle NR No Photocontrol Receptacle2 I N F O R M AT I O N Example: L M 2 0 S R 3 H S G 2) Housing Series R2 Roadway Type II R3 Roadway Type III R5 Roadway Type V Options Wattage / Source 20 25 31 40 200W 250W 310W 400W S HPS M MH Distribution Paint3 (blank) BK GY WH Housing Misc. PC Bronze (standard) Black Gray White SS SH HSG Housing Unit Photocontrol Included per Voltage Specified2 Stainless Steel Fasteners (external) Shorting Cap2 R2 Roadway Type II Photocontrol Receptacle R3 Roadway Type III (blank) NEMA Photocontrol Receptacle (standard) R5 Roadway Type V NR No Photocontrol Receptacle2 O R D E R I N G I N F O R M AT I O N 3) Mounting Example: L M P 3 B Z Notes: Paint Mounting Series 1 LM LuxMaster Shoebox, Medium P W K M Y T 1 2 Square Pole 12” Arm Wall Bracket 12” Arm Adjustable Knuckle External Fitter Yoke Mount Square Tenon Square Tenon 2 Arms 90° Square Tenon 2 Arms 180° 3 4 5 6 7 8 9 R Square Tenon 3 Arms 90° Square Tenon 4 Arms 90° Round Tenon Round Tenon 2 Arms 90° Round Tenon 2 Arms 180° Round Tenon 3 Arms 90° Round Tenon 3 Arms 120° Round Tenon 4 Arms 90° Paint3 BZ Bronze (standard) BK Black GY Gray WH White 2 3 Voids UL/CSA Certified options and not available in MT, TT, and DT voltages PC & SH not available with NR option Other colors available, please contact your local American Electric Lighting representative Product Guide 143 Accessories Mounting Hardware O R D E R I N G D ATA Catalog Number Item Approx Wt. (lbs) Area Rectilinear Arm Field Installed 53-1-BZ1 153-1-BZ1 2-1/2 A B C D 2.031” 2.781” 3.25” 8” 2.031” 3.531” 4” 10” NOTE: Pole must be drilled to match dimensions shown 32 46 Area Wall Mount Bracket C 53-1-W-BZ1 153-1-W-BZ1 D A B C D 5.687” 4.687” 2.781” 2.031” 5.687” 4.687” 3.531” 2.031” NOTE: Pole must be drilled to match dimensions shown 32 46 Round Pole Mounting 12-1/2" 53-1-BZ-WM1 153-1-BZ-WM1 Pole Mount Comes with Rectilinear Arm. Product Guide 7 5 53-VS Polycarbonate Shield For flat lens only. RKASA-EF-BZ1 RKPEM-EF-BZ1 RKPES-EF-BZ1 Mast Arm FItter ASA External Mast Arm FItter PEM External Mast Arm FItter PES External Mast Arm FItter Series ASA Series PEM Series PES 5 5 5 ASA R2/3/5 HS ASA R4 HS PEM R2/R3 HS PES R2/R3 HS LS-HS-BZ LM-HS-BZ AVL-EHS-BZ House-Side Shield ASA Internal for R2, R3, R5 Reflectors ASA Internal for R4 Reflectors PEM Internal for R2, R3, R5 Reflectors PES Internal for R2, R3, R5 Reflectors LS External, Bronze LM External, Bronze AVL External, Bronze Series 53 Series 153 Series PEM Series PES Series LS Series LM Series AVL 5 5 Notes: 1 Standard finish is dark bronze. For other finishes change BZ to BK (black) or WH (white) 144 Series 53 Series 153 For more information please visit our website: www.americanelectriclighting.com 5 5 5 5 Accessories Mounting Hardware AVA I L A B I L I T Y 53 153 AVL LS LM ASA 53-1-BZ 153-1-BZ – – – – 53-1-W-BZ 153-1-W-BZ – – – – 53-1-BZ-WM 153-1-BZ-WM – – – – 9401-H 9401-H – – – – 9401-G 9401-G – – – – RK53-HS-SHLD RK153-HS-SHLD AVL EHS BZ LS-HS LM-HS-BZ – – – See chart below – – See chart below – – See chart below – – See chart below PES PEM VMR VLR – – – – – – – – – – – – – – – – – – – – PES-HS-BZ1 PEM-HS-BZ1 VMR-EHS-BZ1 VLR-EHS-BZ1 See chart below See chart below See chart below See chart below See chart below See chart below See chart below See chart below Rectilinear Arm, Dark Bronze Wall Mount Bracket, Dark Bronze Round Pole Mounting, Dark Bronze Single-Arm Steel Bracket, Dark Bronze Single-Arm Steel Bracket, Galvanized House-Side Shield, Dark Bronze 4-1/4” Pole Top Tenon Adapter, Dark Bronze 4-7/8” Pole Top Tenon Adapter, Dark Bronze Rectilinear Arm, Dark Bronze Wall Mount Bracket, Dark Bronze Round Pole Mounting, Dark Bronze Single-Arm Steel Bracket, Dark Bronze Single-Arm Steel Bracket, Galvanized House-Side Shield, Dark Bronze 4-1/4” Pole Top Tenon Adapter, Dark Bronze 4-7/8” Pole Top Tenon Adapter, Dark Bronze NOTES: 1 For R2 and R3 optics only Standard finish is dark bronze, contact American Electric Lighting for other finishes Pole Top Tenon Adapters1 Drill Pattern 1@90º 2@90º 3@90º 4@90º 2@180º 3@120º Standard 4-1/4” TMS-20-190 TMS-20-290 TMS-20-390 TMS-20-490 TMS-20-280 TMS-20-320 Optional 4-7/8” – – – T47-20-490 – – Standard 4-1/4” TMS-25-190 TMS-25-290 TMS-25-390 TMS-25-490 TMS-25-280 TMS-25-320 Optional 4-7/8” – – – T47-25-490 – – Mounting Pattern 2-3/8” OD Tenon Mounting Pattern 2-7/8” OD Tenon NOTES: 1 For use with AVL and ASA only Product Guide 145 Accessories Steel Bracket - Prime Coated (For Horizontally Mounted Luminaires) M O U N T I N G Catalog Number 9401 O P T I O N S Item FABRICATED STEEL BRACKET — SINGLE ARM For mounting on 2'' (23/8'' OD) standard pipe or pole top tenon. 12'' spread. Effective Projected Area (Sq. Ft.) Approx. Wt. (Lbs.) .4 10 See Isotach Wind Map, page 189 Note: Above brackets available with Galvanized Finish. To order add -G suffix to catalog number. 146 Product Guide For photometric information please visit our website: www.americanelectriclighting.com Accessories M M OO UU NN TT II NN GG OO PP TT II OO NN SS Pole Mount, secured with solid steel plate, attaches luminaire directly to square pole. Full length mounting screws secure luminaire, arm and pole. Catalog Number - LMPBZ Wall Mount Arm secures luminaire to wall plate with full length mount screws. Full length mounting screws secure luminaire to arm and wall plate. Square/round Tenon Adapter mounts on top of round or square pole for luminaire attachment. Makes a smooth transition from pole to luminaire. Available mounting arrangements listed below. Catalog Number - LM5BZ Catalog Number - LMWBZ Adjustable Knuckle for pole attachment of luminaire. Makes a smooth transition from pole to luminaire. Wraparound Yoke - Luminaire is suspended above mounting surface by mount and extends above poles. Catalog Constructable Option Catalog Number - LMKBZ Catalog Number - LMGBZ Catalog Number Description LMTBZ LM1BZ LM2BZ LM3BZ LM4BZ LM5BZ LM6BZ LM7BZ LM8BZ LM9BZ LM0BZ Square Tenon with 1 Arm Square Tenon with 2 Arms at 90° Square Tenon with 2 Arms at 180° Square Tenon with 3 Arms Square Tenon with 4 Arms Round Tenon with 1 Arm Round Tenon with 2 Arms at 90° Round Tenon with 2 Arms at 180° Round Tenon with 3 Arms at 90° Round Tenon with 3 Arms at 120° Round Tenon with 4 Arms at 90° Mast Arm Mount - Luminaire is attached to curved mast arm for mounting to pole or structure. Catalog Number - LMMBZ Product Guide 147 Area Lighting B A L L A S T M AT R I C E S ASA Watts 07S 07M 10S 10M 13S 14S 15S 15M 17M 20S 23S 25S 23M 25M 31S 40S 40M 120 CA,CT,RH,RN XH,XN CA,CT,RH,RN CA,XH,XN RH,RN RH,RN CA,CT,RH,RN XH,XN CA CA CA CA,XH,XN CA CA,SC CA CA,CT CA,CT,SC 208 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA CA CA CA CA CA,SC CA CA,CT CA,SC 240 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA CA,RH,RN CA CA,XH,XN CA CA,SC CA CA,CT CA,CT,SC MT7 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA CA CA CA CA CA,SC CA CA,SC TT3 CT,XH,XN XH,XN CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA CA CA,CT CA,CT - 5T4 CA CA CA CA 120 CA,CT,RH,RN XH,XN CA,CT,RH,RN CA,XH,XN RH,RN RH,RN CA,CT,RH,RN XH,XN CA SC CA 208 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA SC CA 240 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA SC CA TT3 CT,XH,XN XH,XN CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA SC CA 5T4 - 277 CA,CT,XH,XN XH,XN CA,CT,XH,XN CA,XH,XN CA,CT,XH,XN XH,XN CA CA CA CA CA CA,SC CA CA,CT CA,SC 347 XH,XN XH,XN CT,XH,XN XH,XN XH,XN CA CA CA,CT,SC CA - 480 XH,XN CA,XH,XN CA,XH,XN CA CA CA CA,SC CA CA CA,SC DT2 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN XH,XN CA CA CA CA,XH,XN CA CA,CT,SC CA CA,CT CA,CT MT1 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA CA CA CA CA CA,SC CA CA,SC MT2 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA CA CA CA CA CA,SC CA CA,SC 277 CA,CT,XH,XN XH,XN CA,CT,XH,XN CA,XH,XN CA,CT,XH,XN XH,XN CA SC CA 347 XH,XN XH,XN CT,XH,XN XH,XN XH,XN CA SC CA 480 XH,XN CA,XH,XN CA,XH,XN CA SC CA DT2 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN XH,XN CA SC CA MT1 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA SC CA MT2 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA SC CA ASA continued Watts 07S 07M 10S 10M 13S 14S 15S 15M 17M 20S 23S 25S 23M 25M 31S 40S 40M PES Watts 07S 07M 10S 10M 13S 14S 15S 15M 17M 20M 25M PES continued Watts 07S 07M 10S 10M 13S 14S 15S 15M 17M 20M 25M 148 MT7 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA SC CA Product Guide For photometric information please visit our website: www.americanelectriclighting.com Area Lighting B A L L A S T M AT R I C E S PEM Watts 20S 23S 25S 23M 25M 31S 32M 35M 40S 40M 120 CA CA CA,XH,XN CA CA,SC CA SC SC CA,CT CA,CT,SC 208 CA CA CA CA CA,SC CA SC SC CA,CT CA,SC 240 CA,RH,RN CA CA,XH,XN CA CA,SC CA SC SC CA,CT CA,CT,SC MT7 CA CA CA CA CA,SC CA SC SC CA,SC TT3 CA CA,CT CA,CT SC SC - 5T4 CA CA CA CA 120 CA,CT,RH,RN CA,CT,RH,RN CA,XH,XN RH,RN RH,RN CA,CT,RH,RN XH,XN CA SC 208 CA,CT,XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA SC 240 CA,CT,XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA SC TT3 CT,XH,XN CT,XH,XN XH,XN XH,XN CA SC 5T4 - 277 CA CA CA CA CA,SC CA SC SC CA,CT CA,SC 347 CA CA,CT,SC SC SC CA - 480 CA CA CA,SC CA SC SC CA CA,SC DT2 CA CA CA,XH,XN CA CA,CT,SC CA CA,CT CA,CT MT1 CA CA CA CA CA,SC CA SC SC CA,SC MT2 CA CA CA CA CA,SC CA SC SC CA,SC 277 CA,CT,XH,XN CA,CT,XH,XN CA,XH,XN CA,CT,XH,XN XH,XN CA SC 347 XH,XN CT,XH,XN XH,XN XH,XN CA SC 480 XH,XN CA,XH,XN CA,XH,XN CA SC DT2 CA,CT,XH,XN CA,CT,XH,XN XH,XN XH,XN CA SC MT1 CA,CT,XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA SC MT2 CA,CT,XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA SC PEM continued Watts 20S 23S 25S 23M 25M 31S 32M 35M 40S 40M VMR Watts 07S 10S 10M 13S 14S 15S 15M 17M 20M VMR continued Watts 07S 10S 10M 13S 14S 15S 15M 17M 20M MT7 CA,CT,XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA SC Product Guide 149 Area Lighting B A L L A S T M AT R I C E S VLR Watts 23S 23M 25S 25M 31S 40S 40M 45M 75M X1S X1M 120 CA CA CA,XH,XN CA,SC CA CA,CT CA,CT,SC CA,CT,SC CA CA CA,SC 208 CA CA CA CA,SC CA CA,CT CA,SC CA,SC CA CA CA,SC 240 CA CA CA,XH,XN CA,SC CA CA,CT CA,CT,SC CA,CT,SC CA CA SC TT3 CA,CT CA,CT CA 5T4 CA CA CA CA CA CA 277 CA CA CA CA,SC CA CA,CT CA,SC CA,CT,SC CA CA CA,SC 347 CA CA,CT,SC CA CA CA 480 CA CA,SC CA CA CA,SC CA,SC CA CA DT2 CA CA CA,XH,XN CA,CT,SC CA CA,CT CA,CT CA,CT,SC CA CA CA,SC MT1 CA CA CA CA,SC CA CA,SC CA,CT,SC CA CA CA,SC 277 CA CA,SC CA SC SC CA CA,SC SC SC CA CA,CT,SC 347 CA SC SC SC CA,CT CA,CT,SC SC SC CA CA,CT 480 CA CA CA SC SC CA CA,SC SC SC CA SC DT2 CA, CT SC CA SC SC CA CA,SC SC CA CA DT4 CT - VLR continued Watts 23S 23M 25S 25M 31S 40S 40M 45M 75M X1S X1M MT7 CA CA CA CA,SC CA CA,SC CA,CT,SC CA CA CA,SC AVL and AVL BIA Watts 25S 25M 31S 32M 35M 40S 40M 45M 75M 1XS 1XM 120 CA CA,SC CA SC SC CA CA,SC SC SC CA CA,SC 208 CA CA,SC CA SC SC CA CA,SC SC SC CA,CT CA,SC 240 CA CA,SC CA SC SC CA CA,SC SC SC AVL and AVL BIA continued Watts 25S 25M 31S 32M 35M 40S 40M 45M 75M 1XS 1XM 150 MT1 CA CA,SC CA SC SC CA CA,SC SC CA CA,SC Product Guide MT2 CA CA,SC CA SC SC CA CA,SC SC CA CA,SC MT7 CA CA,SC CA SC SC CA CA,SC SC CA CA, SC TT7 CA SC SC SC CA,CT CA,SC,CT SC CA CA For photometric information please visit our website: www.americanelectriclighting.com MT2 CA CA CA CA,SC CA CA,SC CA,CT,SC CA CA CA,SC Area Lighting B A L L A S T M AT R I C E S LuxMaster® Series 53 Watts 07S 07M 10S 10M 13S 14S 15S 15M 17M 120 CA,CT,RH,RN XH,XN CA,CT,RH,RN CA,XH,XN RH,RN RN,RH CA,CT,RN,RH XH,XN CA 208 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA 240 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA 277 CA,CT,XH,XN XH,XN CA,CT,XH,XN CA,XH,XN CA,CT,XH,XN XH,XN CA 347 XH,XN XH,XN CT,XH,XN XH,XN XH,XN CA 480 XH,XN CA,XH,XN CA,XH,XN CA DT2 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN XHX,XN CA LuxMaster® Series 53 continued Watts 07S 07M 10S 10M 13S 14S 15S 15M 17M MT1 CA,CT,XN,XH XN,XH CA,CT,XN,XH XH,XN CA,CT,XH,XN XH,XN CA MT2 CA,CT,XN,XH XH,XN CA,CT,XH.XN XH,XN CA,CT,XH.XN XH,XN CA MT7 CA,CT,XN,XH XN,XH CA,CT,XN,XH XH,XN CA,CT,XH.XN XH,XN CA TT3 CT,XN,XH XN,XH CT,XN,XH XH,X XH,XN CA LuxMaster® Series 153 Watts 20S 23S 23M 25S 25M 31S 40S 40M 120 CA CA CA CA,XH,XN CA,SC CA CA,CT CA,CT,SC 208 CA CA CA CA CA,SC CA CA,CT CA,SC 240 CA,RH,RN CA CA CA,XH,XN CA,SC CA CA,CT CA,CT,SC 277 CA CA CA CA CA,SC CA CA,CT CA,SC 347 CA CA,CT,SC CA - 480 CA CA MR CA CA CA,SC DT2 CA CA CA CA,XH,XN CA,CT,SC CA CA,CT CA,CT LuxMaster® Series 153 continued Watts 20S 23S 23M 25S 25M 31S 40S 40M MT1 CA CA CA CA CA,SC CA CA,SC MT2 CA CA CA CA CA,SC CA CA,SC MT7 CA CA CA CA CA,SC CA CA,SC TT3 CA CA,CT CA,CT - Product Guide 151 Area Lighting B A L L A S T M AT R I C E S LuxMaster® Classic Series LS Watts 03S 05S 07S 07M 10S 10M 13S 14S 15S 15M 17M 120 RN RH,RN CA,CT,RH,RN XH,XN CA,CT,RH,RN CA,XH,XN RH,RN RH,RN CA,CT,RH,RN XH,XN CA 208 CA,CT,XH,XN XH,XN CA,CT,XN,XH XH,XN CA,CT,XN,XH XN,XH CA 240 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA 277 CA,CT,XH,XN XH,XN CA,CT,XH,XN CA,XH,XN CA,CT,XH,XN XH,XN CA 347 XH,XN XH,XN CT,XH,XN XH,XN XH,XN CA 480 XH,XN CA,XH,XN CA,XH,XN CA DT2 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN XH,XN CA LuxMaster® Classic Series LS continued Watts 03S 05S 07S 07M 10S 10M 13S 14S 15S 15M 17M MT1 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA MT2 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA MT7 CA,CT,XH,XN XH,XN CA,CT,XN,XH XH,XN CA,CT,XH,XN XH,XN CA TT3 CT,XH,XN XH,XN CT,XH,XN XH,XN XH,XN CA LuxMaster® Classic Series LM Watts 07S 07M 10S 10M 13S 14S 15S 15M 17M 20S 23S 25S 23M 25M 31S 40S 40M 120 CA,CT,RH,RN XH,XN CA,CT,RH,RN CA,XH,XN RH,RN RH,RN CA,CT,RH,RN XH,XN CA CA CA CA,XH,XN CA CA,SC CA CA,CT CA,CT,SC 208 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA CA CA CA CA CA,SC CA CA,CT CA,SC 240 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA CA,RH,RN CA CA,XH,XN CA CA,SC CA CA,CT CA,CT,SC 277 CA,CT,XH,XN XH,XN CA,CT,XH,XN CA,XH,XN CA,CT,XH,XN XH,XN CA CA CA CA CA CA,SC CA CA,CT CA,SC 347 XH,XN XH,XN CT,XH,XN XH,XN XH,XN CA CA,CT CA,CT,SC CA - 480 XH,XN CA,XH,XN CA,XH,XN CA CA CA CA,SC CA CA CA,SC LuxMaster® Classic Series LM continued Watts 07S 07M 10S 10M 13S 14S 15S 15M 17M 20S 23S 25S 23M 25M 31S 40S 40M 152 MT7 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA CA CA CA CA CA,SC CA CA,SC Product Guide TT3 CT,XH,XN XH,XN CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA CA CA,CT CA,CT - 5T4 CA CA CA CA For photometric information please visit our website: www.americanelectriclighting.com DT2 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN XH,XN CA CA CA CA,XH,XN CA CA,CT,SC CA CA,CT CA,CT MT1 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA CA CA CA CA CA,SC CA CA,SC MT2 CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA,CT,XH,XN XH,XN CA CA CA CA CA CA,SC CA CA,SC FLOODLIGHTING ACP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154 UltraFlood™ Series 75 . . . . . . . . . . . . . . . . . . . .156 UltraFlood™ Series 77 . . . . . . . . . . . . . . . . . . . . .158 Energy Saver Series CES . . . . . . . . . . . . . . . . . .160 Quartz Flood Series 570 . . . . . . . . . . . . . . . . . . .162 Quartz Flood Series 474 . . . . . . . . . . . . . . . . . . .163 AmeriSport™ Series ASP . . . . . . . . . . . . . . . . .164 Sportslighting Series SPF . . . . . . . . . . . . . . . . .166 Options & Accessories . . . . . . . . . . . . . . . . . . . .168 Ballast Matrices . . . . . . . . . . . . . . . . . . . . . .173-174 American Electric Lighting® 153 ACP Series American Compact Floodlight 70-400W HPS; 175-400W MH P R O D U C T O V E R V I E W NEW Features: NEMA beam patterns available in a variety of options Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Door is hinged and easily removable for quick maintenance Fully pivoting painted wraparound yoke is standard, tenon and galvanized yoke mounting options are available for precise aiming UL listing is standard @ 40º ambient For easy maintenance, tool-less entry is available Standardized hardware for single-tool internal maintenance Suitable for -40°C to 40°C HPS / -30ºC to 40ºC MH Lens is thermal shock and impact resistant tempered flat glass Approved for use in 1.5 G vibration applications Applications: Auto dealerships Schools Construction sites Recreational areas Churches Industrial sites Shopping centers Parking lots Substations Building facades DIMENSIONS All electrical components warranted by American Electric Lighting's 6-year guarantee PREFERRED SELECTION CATALOG NUMBERS ACP 15S RN 120 76 EC NL TL ACP 23S CA MT1 76 EC 0643 TL NL ACP 40M SC MT7 76 TM TL ACP 40M SC MT1 76 LC 0443 TL PC ACP 40M SC MT1 76 0443 TL NL ACP 40S CA MT1 76 EC LC 0443 TL PC Effective Projected Area (EPA) The EPA for the ACP Series is 1.60 sq. ft. Approx. Wt. = 35 lbs. 154 Product Guide For photometric information, visit our website, www.americanelectriclighting.com ACP Series American Compact Floodlight 70-400W HPS; 175-400W MH O R D E R I N G I N F O R M AT I O N Example: A C P 4 0 M C A M T 1 7 6 0 4 4 3 L C T L P C Series ACP American Compact Flood Wattage / Source 07 10 15 17 20 25 31 40 23 70W 100W 150W 175W1 200W2 250W 310W2 400W 250/400W Wired 250W3 24 250/400W Wired 400W2, 3 S HPS M MH Voltage Ballast RN Reactor Normal Power Factor4 RH Reactor High Power Factor4 XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA (Auto Reg) CT CWI 120 208 240 277 347 480 MT1 MT2 MT7 TT3 5T4 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V 5-tap Wired 480V NEMA Beam Pattern 55 66 76 5H x 5V1 6H x 6V 7H x 6V Refer to the ballast matrix on page 173 for compatibility. Options Lamp Mounting5 LC Lamp Included, Clear (blank) Wraparound Yoke Mount (standard)1 LD Lamp Included, Deluxe YG Wraparound Yoke Galvanized TM Tenon Slipfitter Fusing7 SF Single Fuse (120, 277, 347V) Paint6 DF Double Fuse (208, 220, 240, 480V) (blank) Bronze (standard) BK Black Cord Type* Cord Length* GY Gray 04 4’ 63 16-3 WH White 05 5’ 44 14-48 06 6’ 43 14-3 Terminal Block 08 8’ 23 12-3 (blank) Terminal Block Factory Wire 10 10’ T2 Wired to L1 and L2 Position *Cord length and type 12 12’ T3 3 Wire Operation should be combined to 15 15’ (L1, N, L2 Position) form one number. 20 20’ Ex: 0423 25 25’ Listing 30 30’ (blank) UL Listed (standard) CS CSA Certified Misc. XL No Listing TL Tool-less Entry PC Photocontrol Included per Photocontrol Receptacle Voltage Specified (blank) Photocontrol Receptacle (standard) 5H 50 Hertz Ballast Frequency9 NR No PEC Receptacle NL NEMA Label Starter2 (blank) Open Board (standard) OP Open Board Plug-in EC Encapsulated Plug-in Notes: 1 MH only 2 HPS only 3 Available in CA ballast option only 4 Available in 120V for 50-150W HPS, 220 to 240V only available for 200-400W HPS; not available in MH 5 Painted to match fixture 6 Other colors available, please contact your local American Electric Lighting representative 7 Not available in multi-tap ballast options 8 For 3-wire operation and ground 9 Limited availability, please contact your local American Electric Lighting representative Product Guide 155 UltraFlood™ Series 75 Heavy Duty Floodlight 100-400W HPS; 175-400W MH P R O D U C T O V E R V I E W Features: NEMA beam patterns available in a variety of options including horizontal and vertical lamps Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Door is hinged and easily removable for quick maintenance Fully pivoting painted yoke is standard, tenon and galvanized yoke mounting options are available for precise aiming UL listing is standard For easy of maintenance, tool-less entry and ballast tray are available options Lens is thermal shock and impact resistant tempered glass Hydroformed reflector Suitable for -30°C MH / -40°C HPS Applications: Auto dealerships Schools Construction sites Recreational areas Storage yards Office Buildings Airports Churches Industrial sites Shopping centers Parking lots Substations Building facades DIMENSIONS Yoke Mount All electrical components warranted by American Electric Lighting's 6-year guarantee PREFERRED SELECTION CATALOG NUMBERS 75 40M SC MT1 66 0443 TL NL 75 40S CA MT1 76 EC 0443 TL NL 75 40S CA MT1 76 TM EC TL NL 75 40M SC MT1 76 TM TL NL 75 25S CA MT1 76 EC 0443 TL NL 75 25S CA MT1 76 TM EC TL NL Vertical Tenon Mount Effective Projected Area (EPA) The EPA for the UltraFlood™ Series 75 is 2.75 sq. ft. Approx. Wt. = 37 lbs. 156 Product Guide For photometric information, visit our website, www.americanelectriclighting.com UltraFlood™ Series 75 Heavy Duty Floodlight 100-400W HPS; 175-400W MH O R D E R I N G I N F O R M AT I O N Example: 7 5 4 0 M C A M T 1 6 6 0 6 4 3 L C T L P C Series 75 UltraFlood Wattage / Source 10 15 17 20 25 31 40 23 100W 150W 175W 200W 250W 310W 400W 250/400W Wired 250W 24 250/400W Wired 400W S HPS M MH RN Reactor Normal Power Factor RH Reactor High Power Factor XN High Reactance (Lag) Normal Power Factor XH High Reactance (Lag) High Power Factor CA CWA (Auto Reg) CT CWI SC SCWA MR Mag Reg (3 Coil) Refer to the ballast matrix on page 173 for compatibility. NEMA Beam Pattern Voltage Ballast 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 Wired 240V DT4 Dual Tap 240/480 Wired 480V 5T4 5-tap Wired 480V Vertical Lamp 76 7H x 6V 66 6H x 6V Horizontal Lamp H6 6H x 6V Refer to Optic Distribution Matrix below for compatibility. Options Mounting (blank) Yoke Mount (standard)1 YG Wraparound Yoke Galvanized TM Tenon Slipfitter1 Paint2 (blank) BK GY WH Bronze (standard) Black Gray White Terminal Block3 (blank) Hard wired (standard) TB Terminal Block Factory Wire T2 Wired to L1 and L2 Position T3 3 Wire Operation (L1, N, L2 Position)10 Listing (blank) CS XL UL Listed (standard) CSA Certified No Listing Photocontrol Receptacle (blank) Photocontrol Receptacle (standard) NR No Photocontrol Receptacle4 Starter5 (blank) Open Board (standard) EC Encapsulated plug-in OP Open board plug-in Lamp LC LD Fusing6 SF DF Lamp Included, Clear Lamp Included, Deluxe Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Cord Length* 04 4’ 05 5’ 06 6’ 08 8’ 10 10’ 12 12’ 15 15’ 20 20’ 25 25’ 30 30’ Misc. TL PC BT SS 5H NL PGS SH Cord Type* 63 16-3 44 14-47 43 14-3 23 12-3 *Cord length and type should be combined to form one number. Ex: 0423 Tool-less Entry Photocontrol Included per Voltage Specified4 Removable Ballast Stainless Steel fastener (external) 50 Hertz Ballast Frequency8 NEMA Label Ballistic Shield9 Shorting Cap4 Notes: 1 Painted to match fixture 2 Other colors available, please contact your local American Electric Lighting representative 3 Voids UL and CSA Listing 4 PC, and SH not available with NR option 5 HPS only 6 Voids UL and CSA listing, not available in MT, TT, and DT voltages 7 For 3-wire operation and ground 8 Limited availability, please contact your local American Electric Lighting representative 9 Ships separately 10 Not available in 120V Optic Distribution 10S 15S 20S 25S 40S 17M 25M 40M 76 N N N N N N N N 66 - N N N H6 N N N N N N N N Product Guide 157 UltraFlood™ Series 77 Heavy Duty Floodlight 400-1000W HPS; 400-1000W MH P R O D U C T O V E R V I E W Features: NEMA beam patterns available in a variety of options with horizontal lamp Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance Door is hinged and easily removable for quick maintenance Fully pivoting painted yoke is standard, tenon and galvanized yoke mounting options are available for precise aiming UL listing is standard For easy maintenance, tool-less entry is available Suitable for -30°C MH / -40°C HPS Lens is thermal shock and impact resistant tempered glass All electrical components warranted by American Electric Lighting's 6-year guarantee Applications: Auto dealerships Schools Churches Industrial sites Shopping centers Parking lots Substations Building facades DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS 77 X1M CA MT1 76 0443 TL NL 77 X1M CA MT1 76 TM TL NL 77 X1S CA MT1 76 0443 TL NL 77 X1S CA MT1 76 TM TL NL Effective Projected Area (EPA) The EPA for the UltraFlood™ Series 77 is 3.97 sq. ft. Approx. Wt. = 65 lbs. 158 Product Guide For photometric information, visit our website, www.americanelectriclighting.com UltraFlood™ Series 77 Heavy Duty Floodlight 400-1000W HPS; 400-1000W MH O R D E R I N G I N F O R M AT I O N Example: 7 7 X I M C A M T 7 7 6 T M Wattage / Source Series 77 UltraFlood 40 400W 75 750W X1 1000W Voltage Ballast S HPS M MH CA CWA (Auto Reg) Refer to the ballast matrix on page 174 for compatibility. NEMA Beam Pattern 120 208 240 277 347 480 MT1 MT2 MT7 TT3 DT2 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 347V Dual Tap 120/240 wired 240 5T4 5 Tap Wired 480V Horizontal Lamp 65 6H x 5V 66 6H x 6V 76 7H x 6V Refer to optic distribution matrix below for compatibility. Options Mounting (blank) Yoke Mount (standard)1 YG Yoke Galvanized TM Tenon slipfitter1 Paint2 (blank) BK GY WH Bronze (standard) Black Gray White Terminal Block3 (blank) Hard wired (standard) TB Terminal Block T2 Wired to L1 and L2 T3 3 Wire Operation (L1, N, L2 Position)8 Listing (blank) CS XL UL Listed (standard) CSA Certified No Listing Photocontrol Receptacle (blank) Photocontrol Receptacle NR No Photocontrol Receptacle4 Lamp LC LD Fusing5 SF DF Notes: Single Fuse (120, 277, 347V) Double Fuse (208, 220, 240, 480V) Cord Length* 04 4’ 05 5’ 06 6’ 08 8’ 10 10’ 12 12’ 15 15’ 20 20’ 25 25’ 30 30’ Misc. TL PC SS 5H NL SH Cord Type* 63 16-3 44 14-46 43 14-3 23 12-3 PW Pre-wire (Slip fitter only) *Cord length and type should be combined to form one number. Ex: 0643 Tool Less Entry Photocontrol Included per Voltage Specified4 Stainless Steel fasteners (external) 50 Hertz Ballast Frequency7 NEMA Label Shorting Cap4 1 Painted to match fixture 2 Other colors available, please contact your local American Electric Lighting representative 3 Voids UL and CSA certification 4 PC, and SH not available with NR option 5 Voids UL and CSA listing, not available in MT, TT, & DT voltages 6 For 3-wire operation and ground 7 Limited availability, please contact your local American Electric Lighting representative 8 Not available in 120V Optic Distribution X1S X1M 65 N - 66 N - 76 N Lamp Included, Clear Lamp Included, Deluxe Product Guide 159 Energy Saver Series CES Floodlight 35-150W HPS; 50-175W MH P R O D U C T O V E R V I E W Features: Durable polyester powder paint finish Die-cast aluminum housing Fully gasketed Lens secured by hinged, captive bezel with captive screw or NEMA latch closure High efficiency aluminum reflector Provides broad floodlighting coverage Impact and thermal resistant tempered glass lens UL listing in standard Applications: PREFERRED SELECTION CATALOG NUMBERS Waterfront areas Building facades Residential areas Recreational areas Commercial environments Parking areas Industrial sites Storage areas CES 15S RN 120 LC DIMENSIONS Effective Projected Area (EPA) The EPA for the Energy Saver Series CES is 0.61 sq. ft. Approx. Wt. = 18 lbs. 160 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Energy Saver Series CES Floodlight 35-150W HPS; 50-175W MH O R D E R I N G I N F O R M AT I O N Example: C E S 0 3 S C A 1 2 0 B K Wattage / Source Series CES Compact Energy Saver Floodlight 03 05 07 10 15 17 35W 50W 70W 100W 150W 175W S HPS M MH Refer to the ballast matrix on page 174 for compatibility. Ballast Voltage RN Reactor, Normal Power Factor RH Reactor, High Power Factor XN High Reactance (lag), Normal Power Factor XH High Reactance (lag), High Power Factor CA CWA (Auto Reg) 120 120V Options Mounting (blank) 1/2” Threaded Knuckle Mount WY Wrap Around Yoke Lamp (blank) LC None Lamp Included, Clear Paint (blank) BK WH Misc. TL Tool Less Entry Bronze (standard) Black White Photocontrol Receptacle (blank) None PC Button Photocontrol Product Guide 161 Quartz Flood Series 570 Floodlight 500W Quartz P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance, bronze is standard color Single door access to lamp and electrical components for quick, easy installation and servicing Suitable for -30°C MH / -40°C HPS UL listing is standard Lens is thermal shock and impact resistant tempered glass 570-61/L Applications: Transportation terminals Building facades Sports lighting Parking lots Industrial areas Commercial areas Residential areas Security lighting Fixture Available 570-61/L DIMENSIONS Effective Projected Area (EPA) The EPA for the Floodlight, Series 570 is 0.72 sq. ft. Approx Wt = 3.5 lbs 162 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Clear Lamp Included (120V) Quartz Flood Series 474 Floodlight 1500W Quartz P R O D U C T O V E R V I E W Features: Rugged die-cast aluminum housing is powder-coated for durability and corrosion resistance, bronze is standard color Single door access to lamp and electrical components for quick, easy installation and servicing Permanently attached bezel is secured by twin captive spring latches UL listing is standard Lens is thermal-, shock-, and impact-resistant tempered glass for lamp protection Applications: Transportation terminals Building facades Sports lighting Parking lots Industrial areas Commercial areas Residential areas Security lighting Fixtures Available 474-61/L-208V M4 Lamp Included (208V) 474-61/L-240V M4 Lamp Included (240V) 474-61/L-277V M4 Lamp Included (277V) DIMENSIONS Effective Projected Area (EPA) The EPA for the Floodlight, Series 474 is 1.13 sq. ft. Approx Wt = 5.5 lbs Product Guide 163 AmeriSport™ Series ASP Sports Floodlight 400-1500W MH W PP RR OO DD UU CC TT OO VV EE RR VV II EE W Features: Two-piece die-cast aluminum ballast housing mounted to galvanized steel trunnion. Ballast is removable and hinged with captive fastener. Steel trunnion features vertical and horizontal aiming scale with vertical repositioning stop. All external hardware is stainless steel. White corrosion resistant polyester powder finish standard; other architectural colors available. Heavy-gauge anodized reflector with six distributions available. "Flux manager" available for optimal glare and spill light control. Transverse mounting of lamp. Lamp support included. Optical chamber sealed to inhibit entrance of contaminants. Hinged lens is thermal-, shock- and impact-resistant tempered glass. Lens frame is galvanized and secured by stainless steel spring clips for servicing of lamp. US. Patent no. 6,190,023. Canada Patent no. 2,212,014. Fixture mounted by securing trunnion directly to cross arm. Mounting hardware provided. Suitable for -30°C MH / -40°C HPS Applications: UL listed, suitable for wet locations. Below horizontal aiming orientation only. Listed and labeled to comply with Canadian Standards. Stadiums Sports fields Arenas Tracks Courts All electrical components warranted by American Electric Lighting’s 6-year guarantee. DIMENSIONS Effective Projected Area (EPA) The EPA for the Sports Floodlight Series SPF is 3.3 sq. ft. Approx. Wt. = 55 lbs. 164 Product Guide For photometric information, visit our website, www.americanelectriclighting.com AmeriSport™ Series ASP Sports Floodlight 400-1500W MH O R D E R I N G I N F O R M AT I O N Example: A S P X 5 M C A M T 1 G N ASP AmeriSport 40 400W X1 1000W X5 1500W M Metal Halide CA CWA SC SCWA (Pulse Start)1 CT CWI2 Optics Voltage Ballast Wattage / Source Series 120 208 240 277 347 480 MT1 MT2 MT7 TT3 5T8 120V 208V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V Tri-tap Wired 277V 5-tap Wired 480V G General Purpose H Heavy Duty Distribution N M W NX Narrow Beam Medium Beam Wide Beam Narrow Beam with Flux Manager DX Medium Beam with Flux Manager WX Wide Beam with Flux Manager Options Listing (blank) UL Listed (standard) CS CSA Certified3 XL No Listing Fusing4 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 220, 240, 480V) Cord Length* 03 3' Cord 05 5' Cord 08 8' Cord Cord Type* 23 12-3 SEO Cord 43 14-3 SEO Cord 63 16-3 SEO Cord Frequency 5H 50 Hertz Ballast Frequency5 Filter CF Charcoal Filter6 Connector 3P 3 Prong Plug7,8,9,10 Quartz Restrike QS Quartz Restrike (Lamp not included) Notes: 1 400W MH only 2 Available in 208 and 240V only 3 Consult factory for CSA availability 4 Single tap only 5 Limited availability, please contact your local American Electric Lighting representative 6 Must use with heavy duty optical 7 Must use mating receptacle, provided by others 8 Not available with 1500W, 120V 9 Use with pre-wired gauges and cross-arms 10 For use with 0363 cord length and type only *Cord length and type should be combined to form one number. Ex: 0523 Lamp LC Lamp Included, Clear (Ships separately) Product Guide 165 Sportslighting Series SPF Sports Floodlight 400W & 1000W HPS, 400W-1500W MH P R O D U C T O V E R V I E W Features: Heavy-gauge, hydroformed, aluminum ballast housing is mounted to integral die-cast monoframe with horizontal degree aiming scale and repositioning locator. Die-cast aluminum socket housing provides vertical aiming adjustment, complete with degree aiming scale and repositioning stop. Heavy-gauge, anodized, aluminum reflectors provide a range of NEMA beam spreads. Optical chamber is sealed to inhibit entrance of contaminants. Hinged lens is heavy-duty thermal shock and impact-resistant, tempered glass. Adjustable mounting bracket standard. Porcelain, mogul-base socket with copper alloy, nickel-plated screw shell and center contact. UL listed 1500W, 600V. Fixture is mounted by securing the integral cross-arm mounting bracket directly to the cross-arm. No additional adapters are required. A 5/8"-11UNC mounting bolt is provided. Exposed bolt length is 1-1/2". UL listed, suitable for wet locations. Listed and labeled to comply with Canadian Standards. Suitable for -30°C MH / -40°C HPS Optional painted heavy duty reflector shroud available to protect the reflector. Applications: All electrical components warranted by AEL’s 6-year guarantee. Stadiums Sports fields Arenas Tracks Courts DIMENSIONS PREFERRED SELECTION CATALOG NUMBERS SPF X5M CA MT1 33 SPF X5M CA MT1 44 SPF X5M CA MT1 66 Dimensions EPA: NEMA 2,3: NEMA 4,5,6: Diameter: NEMA 2,3: NEMA 4,5,6: Length: NEMA 2,3: NEMA 4,5,6: Weight: 53 lbs. 166 Product Guide 2.9 ft.2 (.27 m2) 2.5 ft2 (.23 m2) 23-1/8 (58.7) 21-1/2 (54.6) 30 (76.2) 31-1/2 (80) 24 Kg. For photometric information, visit our website, www.americanelectriclighting.com Sportslighting Series SPF Sports Floodlight 400W & 1000W HPS, 400W MH-1500W MH O R D E R I N G I N F O R M AT I O N Example: S P F X 5 M C A M T 1 5 5 Wattage / Source Series SPF Sports Floodlight 40 400W X1 1000W X5 1500W1 S HPS M MH Voltage Ballast 120 208 220 240 277 347 480 MT1 MT2 MT7 5T4 CA CWA SC SCWA (Pulse Start)2 CT CWI3 120V 208V 220V 240V 277V 347V 480V Multi-tap Wired 120V Multi-tap Wired 240V Multi-tap Wired 277V 5-Tap Wired 480V Optics 22 33 44 55 66 2H x 2V 3H x 3V 4H x 4V 5H x 5V 6H x 6V Options Listing (blank) UL Listed (standard) CS CSA Certified4 XL No Listing Bolt LB Extended Bolt for Wood Crossarm Support LT Lamp Support Fusing5 SF Single Fuse (120, 277, 347V) DF Double Fuse (208, 220, 240, 480V) Connector 3P 3 Prong Plug8,9,10,11 Lamp LC Lamp Included, Clear (Ships separately) Coating TC Non-stick Protective Coating, Black Only Cord Length** 03 3' Cord 05 5' Cord 08 8' Cord Cord Type** 23 12-3 SEO Cord 43 14-3 SEO Cord 63 16-3 SEO Cord **Cord length and type should be combined to form one number. Ex: 0523 Frequency 5H 50 Hertz Ballast Frequency6 Shield GS Glare Shield14 HG Hail Shroud and Glare shield RS Reflector (Hail) Shroud7 Aiming AH Above Horizontal Filter CF Charcoal Filter12 Notes: 1 2 3 4 4 5 6 7 8 9 10 11 12 13 14 Metal Halide only 400W MH Only Available in 208 and 240V only. Not available in HPS Consult factory for CSA availability Must use mating receptacle, provided by others Available in single tap only Limited availability, please contact your local American Electric Lighting representative Heavy duty anodized aluminum shroud Must use mating receptacle, provided by others Use with prewired caged and crossarms For use with 0363 cord length and type only Not available with 1500W, 120V For use with reflector shroud (RS option) only Lamp not included LV and GS not compatible Quartz QS Quartz Restrike13 Paint BK Black WH White Louver LV Internal Louver14 Product Guide 167 Accessories G L A R E S H I E L D S Catalog Approx. Wt. (Lbs.) 2 Number Item RK75 GS BZ RK75 GS LARGE BZ ULTRA FLOOD GLARE SHIELD Manufactured of corrosion-resistant aluminum. For use with Ultra Flood, series 75. Standard finish is bronze. POLYCARBONATE VANDAL SHIELD .6 ULTRA FLOOD GLARE SHIELD Manufactured of corrosion-resistant aluminum. For use with Ultra Flood, series 77. Standard finish is bronze. POLYCARBONATE VANDAL SHIELD .7 .5 RKACP VS COMPACT FLOOD GLARE SHIELD Manufactured of corrosion-resistant aluminum. For use with series 51. Standard finish is bronze.2 COMPACT FLOOD VANDAL SHIELD 75 PGS 40W 77 PGS X1W ACP PGS 40W 75 SERIES BALLISTIC SHIELD, 400W MAX 77 SERIES BALLISTIC SHIELD, 1000W MAX ACP SERIES BALLISTIC SHIELD, 400W MAX RK75 VS RK77 GS BZ RK77 GS LARGE BZ RK77 VS RKACP GS BZ RKACP GS LARGE BZ 168 Effective Projected Area (Sq. Ft.) Product Guide For photometric information, visit our website, www.americanelectriclighting.com 2 2 2 2 2 Accessories For Mounting to Wood Poles S T E E L Catalog Number M O U N T I N G Item B R A C K E T S Effective Projected Area (Sq. Ft.) Approx. Wt. (Lbs.) 9201 SINGLE UNIT BRACKET — Manufactured of 2'' steel pipe with a minimum yield of 35,000 PSI. Requires two 1/2'' lag screws, one 5/8'' through-bolt and one 2'' square flat washer. Prime coated finish. .7 5 9254 SINGLE UNIT BRACKET — Manufactured of 2'' steel pipe with a minimum yield of 35,000 PSI. Requires two 1/2'' lag screws, one 5/8'' through-bolt and one 2'' square flat washer. Prime coated finish. .7 13 9204 SINGLE UNIT BRACKET — Fixture bracket is 3'' 3''- 5/16'' angle steel with 3/4'' - 11/2'' steel bolts. Unit of 2'' steel pipe with minimum yield strength of 35,000 PSI. Requires two 1/2'' lag screws, one 5/8'' through-bolt and one 2'' square flat washer. Prime coated finish. .8 141/4 9205 TWIN UNIT BRACKET — Each fixture bracket is 3'' 3''- 5/16'' angle steel with 3/4'' - 11/2'' steel bolts. Unit of 2'' steel pipe with minimum yield strength of 35,000 PSI. Requires two 1/2'' lag screws, one 5/8'' through-bolt and one 2'' square flat washer. Prime coated finish. .8 271/4 9252 9252-G TWIN UNIT BRACKET — Manufactured of 2'' steel pipe with a minimum yield strength of 35,000 PSI. Requires two 1/2'' lag screws, one 5/8'' through-bolt and one 2'' square flat washer. Prime coated finish. 1.4 24 THREE UNIT BRACKET — Manufactured of 2'' steel pipe with minimum yield strength of 35,000 PSI. Requires two 1/2'' lag screws, one 5/8'' through-bolt and one 2'' square flat washer. Prime coated finish. 1.9 27 (Galvanized) 9253 9253-G (Galvanized) NOTE: Above brackets available with GALVANIZED FINISH, to order add -G suffix to catalog number. (Example: 9252-G.) Product Guide 169 Accessories M O U N T I N G Catalog Number 170 A D A P T E R S Item Approx. Wt. (Lbs.) 9902-H ALUMINUM POLE-TOP MOUNT Slipfitter mounting. Positive three-point mounting support and corrosion-resistant hardware. Fits 2'' or 21/2'' pipe (2'' pipe intrudes 31/16'', 21/2'' pipe intrudes 23/4''.) Furnished with mounting bolts, set screws, and compression fitting for cable entry. Top cover removable for wiring. 3 9906 PIPE CLAMP MOUNT Plated steel and cast aluminum clamp mount with corrosion-resistant hardware for 11/2'' or 2'' pipe installations. 3 9909 PIPE CLAMP MOUNT Plated steel and cast aluminum clamp mount with corrosion-resistant hardware for 3'' pipe installations. 5 Product Guide For photometric information, visit our website, www.americanelectriclighting.com Accessories For Mounting to Steel Poles S T E E L Catalog Number M O U N T I N G Item B R A C K E T S Effective Projected Approx. Area (Sq. Ft.) Wt. (Lbs.) 9333 THREE ARM POLE-BRACKET—12'' spread, arms @ 120° 2'' (23/8'' OD) standard pipe tenon and slipfitter base for mounting to standard 2'' pipe tenons. Prime coated finish. 1.2 34 9343 FOUR ARM POLE-TOP BRACKET—48'' spread, arms @ 90°, 2'' (23/8'' OD) standard pipe tenon and slipfitter base for mounting to standard 2'' pipe tenons. Prime-coated finish. .90 45 9352 TWO ARM POLE-TOP BRACKET — 30'' spread, 2'' (23/8'' OD) standard pipe tenon and slipfitter base for mounting to standard 2'' pipe tenons. Prime-coated finish. .87 21 9353 THREE ARM POLE-TOP BRACKET — 30'' spread between tenons, 2'' (23/8'' OD) standard pipe tenon and slipfitter base for mounting to standard 2'' pipe tenons. Prime-coated finish. 1.7 34 9354 FOUR ARM POLE-TOP BRACKET — 30'' spread between tenons, 2'' (23/8'' OD) standard pipe tenon and slipfitter base for mounting to standard 2'' pipe tenons. Prime-coated finish. 2.3 45 NOTE: Above brackets available with GALVANIZED FINISH, to order add -G suffix to catalog number. (Example: 9252-G) For Steel, Aluminum, Fiberglass and Wood Poles Refer to the Pole Section or Call Your Local American Electric Lighting Representative. Product Guide 171 Options and Accessories AVA I L A B I L I T Y GLARE SHIELDS MOUNTING BRACKETS MOUNTING ADAPTERS POLE-TOP MOUNTING BRACKETS SPORTS FLOOD ACCESSORIES Flood Glare Shield, Dark Bronze Large Flood Glare Shield, Dark Bronze Upper Visor, Glass Lens and Glass Ring for NEMA 4, 5, 61 Upper Visor, Glass Lens and Glass Ring for NEMA 2, 31 Polycarbonate Vandal Shield Ballistic Shield Vertical Single Unit Bracket (19-3/4”H) 4, 5 Vertical Single Unit Bracket (23”H) 4, 5 Crossarm Single Unit Bracket 4, 6 Crossarm Twin Unit Bracket 4, 6 Vertical Twin Unit Bracket 4, 5 Galvanized Vertical Twin Unit Bracket 4, 5 Vertical Three Unit Bracket 4, 5 Galvanized Vertical Three Unit Bracket 4, 5 Aluminum Pole-Top Mount Pipe Clamp Mount for 1-1/2” - 2” Pipe Pipe Clamp Mount for 3” Pipe Three-Arm Pole-Top Bracket (12” spread) Two-Arm Pole-Top Bracket (30” spread) Three-Arm Pole-Top Bracket (30” spread) Four-Arm Pole-Top Bracket (30” spread) Four-Arm Pole-Top Bracket (48” spread) Crossarm Adapter Crossarm Adapter, 45º Bottom Internal Louver, Glass Lens and Lens Ring for NEMA 4, 5, 6 Bottom Internal Louver, Glass Lens and Lens Ring for NEMA 2, 3 Radius Wall Bracket, Dark Bronze Steel Angle Bracket, Dark Bronze Mounting Bracket (for 2” Schedule 40 pipe) Pole-Top Tenon Adapter for 2-3/8” to 2-7/8” OD Tenon Wood Pole, 2-light Wood Pole, 3-light Wood Pole, 4-light ACP 75 77 RKACP GS BZ RK75 GS BZ RK77 GS BZ RKACP GS LARGE BZ RK75 GS LARGE BZ RK77 GS LARGE BZ - - - RKACP VS ACP PGS 40W2 9201 9254 9204 9205 9252 9252-G 9253 9253-G 9902-H 9906 9909 9333 9352 9353 9354 9343 RK75 VS 75 PGS 40W2 9201 9254 9204 9205 9252 9252-G 9253 9253-G 9902-H 9906 9909 9333 9352 9353 9354 9343 RK77 VS 77 PGS X1W3 9201 9254 9204 9205 9252 9252-G 9253 9253-G 9902-H 9906 9909 9333 9352 9353 9354 9343 - - - ASP - 9/16" DIA. ATS U SPF TSU Furnished with weather-tight cord grip for 14-3 SO cord. (Grip for 12-3 SO optional.) Wire Access ACRA45 ACRA 172 Product Guide For photometric information, visit our website, www.americanelectriclighting.com SPF20 GS GL OPT U SPF23 GS GL OPT U ACRA ACRA45 U - - SPF20 LV GL U SPF23 LV GL U ARWB BZ U ASAB BZ U - ASPMB OPT U ATS U - Notes: 1 Louver and glare shield cannot be used simultaneously 2 400W lamp maximum 3 1000W lamp maximum 4 Brackets designed to accommodate fixtures with a maximum weight of 65 lbs. and an EPA of 4.0 5 Tenon mount only 6 Yoke mount only Standard finish is dark bronze, contact American Electric Lighting for other finishes ARWB BZ U SPF - 5/8" Clearance Hole SPFTS U ACRW2 ACRW3 ACRW4 Floodlighting B A L L A S T ACRW2 M AT R I C E S ACRW4 ACRW3 ASAB APSMB OPT U ACP Series Watts 07S 10S 13S 14S 15S 17M 20S 23S 25S 23M 25M 31S 40S 40M 120 CA,CT,RH,RN CA,CT,RH,RN RH,RN RH,RN CA,CT,RH,RN CA CA CA XH,XN,CA CA CA CA CA,CT CA,CT 208 CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA CA CA,CT CA 240 CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA RH,RN,CA CA CA, XH, XN CA CA CA CA,CT CA,CT 277 CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA CA CA,CT CA 347 XH,XN CT,XH,XN CA CA CA,CT,SC CA - 480 XH,XN CA,XH,XN CA,XH,XN CA CA CA CA,SC CA CA CA,SC DT2 CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA, CA,XH,XN CA CA,CT,SC CA,CT CA,CT MT1 CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA,SC CA CA,SC MT2 CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA,SC CA CA,SC ACP Series continued Watts 07S 10S 13S 14S 15S 17M 20S 23S 25S 23M 25M 31S 40S 40M MT7 CA,CT,XH,XN CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA,SC CA CA,SC TT3 CT,XH,XN CT,XH,XN CA CA CA,CT CA,CT - 5T4 CA CA CA CA Product Guide 173 Floodlighting B A L L A S T M AT R I C E S Series 75 Watts 10S 15S 17M 20S 23S 25S 23M 25M 31S 40S 40M 120 CA,CT,RH,RN CA,CT,RH,RN CA CA CA CA,XH,XN CA CA CA CA,CT CA,CT 208 CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA CA CA,CT CA 240 CA,CT,XH,XN CA,CT,XH,XN CA CA,RH,RN CA CA,XH,XN CA CA CA CA,CT CA,CT 277 CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA, CA CA CA,CT CA TT3 XH,XN,CT CA CA CA,CT CA,CT - 5T4 CA CA CA CA 347 CT,XH,XN CA CA CA,CT,SC CA - 480 CA,XH,XN CA,XH,XN CA CA CA CA,SC CA CA CA,SC DT2 CA,CT,XH,XN CA CA CA CA,XH,XN CA CA,CT,SC CA CA,CT CA,CT MT1 CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA,SC CA CA,SC Series 75 continued Watts 10S 15S 17M 20S 23S 25S 23M 25M 31S 40S 40M MT2 CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA,SC CA CA MT7 CA,CT,XH,XN CA,CT,XH,XN CA CA CA CA CA CA,SC CA CA Series 77 Watts 40S 40M 75S X1S X1M 120 CA,CT,XN,XH,MR CA,CT,SC CA CA,CT CA,SC 208 CA,CT CA,CT,SC CA CA,CT CS,SC 220 RN,RH CA CA 240 RH,RN,CA,CT,MR CA,CT,SC CA CA,CT CA,SC TT1 CA CA CA,SC TT7 CA CA CA,SC 277 CA,CT CA,SC CA CA,CT CA,SC 480 CA,MR CA,CT, CA,CT CA,SC DT1 CA,CT,,XN,XH,MR CA,CT CA CA,CT CA,SC DT2 CA,CT,,XN,XH,MR CA,CT CA CA,CT CA,SC Series 77 continued Watts 40S 40M 75S X1S X1M MT7 CA,CT CA,SC CA CA,SC MT8 CA,CT CA,SC CA CA,SC TT3 CA CA CA CA,SC 347 CA CA CA,SC Energy Saver Series CES Watts 03S 05S 05M 07S 07M 10S 10M 15S 15M 17M 174 120 RN,RH RN,RH XN,XH RN,RH XN,XH RN,RH XN,XH RN,RH XN,XH CA 208 CA Product Guide 240 CA 277 XN,XH XN,XH XN,XH XN,XH CA DT2 CA MT1 CA MT2 CA MT7 CA For photometric information, visit our website, www.americanelectriclighting.com DT3 MR CT - DT4 MR CT - MT1 CA,CT CA,SC CA CA,SC MT2 CA,CT CA,SC CA CA,SC DARK TO LIGHT ® ELECTRONIC PHOTOCONTROLS DP 1704 ...................................................................176 DP Series .................................................................177 DE Series .................................................................178 DX Series .................................................................179 DUX Series ..............................................................180 D7790 Series............................................................181 DD Series.................................................................182 DPN Series ..............................................................183 DBE Series...............................................................184 Shorting and Open Caps .......................................185 Photocontrol Accessories ....................................186 Photocontrol Recommendation Chart ................186 ANSI Color Chart ....................................................186 American Electric Lighting® 175 DP 1704 Utility Premium Electronic Locking Type Photocontrol O R D E R I N G I N F O R M AT I O N Features: NEW Special components provide superior reliability for large wattage fixtures or other applications that overheat or damage ordinary photocontrols Silicon photocell provides long-term drift-free light sensing at elevated temperatures Heat stabilized polymers are used in the base, enabling the control to withstand the high temperatures found on 400 and 1,000 watt HID floodlights ANSI standard 1.5 footcandle turn on Fast delivery from stock Eight-year warranty Brown cover for identification Multi-volt, 120/208/240/277 VAC MOV surge protection, 320 Joule, 10,000 AMP Applications: “Best of Everything” control Roadway and area lighting PREFERRED SELECTION CATALOG NUMBERS DP124-1.5-1704 J50 Ordering Information Example: D P 1 2 4 - 1 . 5 - 1 7 0 4 J 5 0 Voltage DP124 Premium Turn-on Level (ftc)1 120/208/240/277 Volts (105–305) 1.5 ANSI Standard 1704 Job Packs J50 50 Units DIMENSIONS Notes: 1 176 Product Guide For more information, visit our website, www.americanelectriclighting.com Other options available, please contact your local American Electric Lighting representative DP Series Silicon Electronic Locking Type Photocontrol O R D E R I N G I N F O R M AT I O N Features: Silicon light sensor Complies with ANSI C136.10-1996 MOV surge protection Long life Energy efficient Six-year warranty Available in job packs of J12 or J50 only Heat stabilized polymers are used in the base, enabling the control to withstand the high temperatures found on 400 and 1,000 watt HID floodlights and other fixtures Inverse ratio (DPR) and fail off (DPF) options available Applications: Inverse Ratio Controls are ideal for areas where it is important to turn on lights early but energy costs are a concern. Turn-off level is lower than turn-on levels. Model listed, DPR124-2.6-TJBK J50, is most commonly ordered. Various other models available. Contact your local American Electric Lighting representative for details and specifications. Roadway and area lighting Floodlights Areas with very high temperatures (DP Series High Temp/Floodlight) Fail Off Controls are occasionally used for leased lighting. Model DPF124-1.5-TJ J50 is most commonly ordered. Various other models available. Contact your local American Electric Lighting representative for details and specifications. PREFERRED SELECTION CATALOG NUMBERS DP124-1.5-TJ J50 DP120-1.5-TJ J50 DP124-1.5-TJBK J50 Ordering Information Voltage DP120 DP124 120 Volts (105–130) 120/240/277 Volts (105–305) DP240 240 Volts (185–305) DP347 347 Volts (300–400) DP480 480 Volts (420–530) DPR124 Multi-volt Inverse ratio DPF124 Multi-volt Fail Off Example: D P 1 2 0 - 1 . 5 - T J B K J 5 0 Turn-on Level (ftc)1 1.0 1.5 2.6 8.0 35 Time Delay (seconds)1 T Energy Saver ANSI Standard IES Recommendation Automile (High Ambient Light) FAA 2-5 Second Turn-off Delay Cover Color 1 Surge Protector J 320 J/10,000 Amp MOV (blank) BK BR P ANSI Standard Color* Black Brown Upward Facing * See chart page 186 Job Packs DIMENSIONS J12 12 Units J50 50 Unit Notes: 1 Other options available, please contact your local American Electric Lighting representative Upward Facing Product Guide 177 DE Series Filtered Silicon Electronic Locking Type Photocontrol O R D E R I N G I N F O R M AT I O N Features: Filtered silicon light sensor Human eye spectral response Complies with ANSI C136.10-1996 MOV surge protection Long life Energy efficient Six-year warranty Available in job packs of J12 and J50 only Silicon sensor with infrared blocking filter Polypropylene cover, neoprene gasket, brass legs, acrylic window Base rated for 120°C Applications: Power consumption: 0.5 watts Roadway and area lighting Areas with variable sky conditions Areas with high temperatures Load rating: 1000 watts, 1800 VA ballast Sealed relay rated for 5000 operations at full load Turn OFF light level is 1.5 times turn ON. 3.4 ounces each PREFERRED SELECTION CATALOG NUMBERS -40 to +70°C ambient, Up to 90° interface per ANSI DE120-1.5-TJ J50 DE124-1.5-TJBK J50 DE124-1.5-TJGY J50 Dielectric strength: 5000 V per ANSI Ordering Information Voltage DE120 DE124 DE347 DE480 120 Volts (105–130) 120/240/277 Volts (105–305) 347 Volts (300–400) 480 Volts (420–530) Example: D E 1 2 0 - 1 . 5 - T J J 5 0 Time Delay (seconds)1 Turn-on Level (ftc)1 1.0 1.5 2.6 8.0 35 Energy Saver ANSI Standard IES Recommendation Automile (High Ambient Light) FAA T 2-5 Second Turn-off Delay (standard) Surge Protector J 320 J/10,000 Amp MOV Cover Color 1 (blank) BK P ANSI Standard Color* Black Upward Facing Job Packs J12 12 Units J50 50 Units * See chart page 186 DIMENSIONS Notes: 1 Upward Facing 178 Product Guide For more information, visit our website, www.americanelectriclighting.com Other options available, please contact your local American Electric Lighting representative DX Series Electronic Locking Type Photocontrol O R D E R I N G I N F O R M AT I O N Features: Silicon light sensor Complies with ANSI C136.10-1996 MOV surge protection Long life Energy efficient Economical Six-year warranty Available in job packs of J12 or J50 only Standard 160 joule, 6500 amp MOV rated for multiple surges Polypropylene cover, Neoprene gasket, brass legs, acrylic window base rated for 120°C Applications: Power consumption: 0.5 watts Roadway and area lighting Security lighting Municipal lighting Load rating: 1000 watts, 1800 VA ballast Sealed relay rated for 5000 operations at full load 3.4 ounces each PREFERRED SELECTION CATALOG NUMBERS -40 to +70°C ambient, Up to 90° interface per ANSI Dielectric strength: 5000 V per ANSI DX124-12A J50 DX124-12A J12 Example: D X 1 2 4 - 1 2 A J 5 0 Ordering Information Voltage DX120 DX124 DX347 DX480 Sensor Turn-on Level (ftc) 120 Volts (105–130) 120/240/277 Volts (105–305) 347 Volts (300–400) 480 Volts (420–530) 1 1.2–3 ftc Turn-on (standard) 2 Silicon Sensor,Time Delay (2-5 seconds) Cover Color A ANSI Standard* Job Packs J12 12 Units J50 50 Units * See chart page 186 DIMENSIONS Product Guide 179 DUX Series Locking Type Photocontrol – UL Listed O R D E R I N G I N F O R M AT I O N Features: Silicon light sensor Complies with ANSI C136.10-1996 MOV surge protection Long life Energy efficient Economical Six-year warranty Available in job packs of J12 or J50 only Standard 160 joule, 6500 amp MOV rated for multiple surges Polypropylene cover, neoprene gasket, brass legs, acrylic window base rated for 120°C Applications: Area lighting Security lighting Yard lighting Power consumption: 0.5 watts Load rating: 1000 watts, 1800 VA ballast Sealed relay rated for 5000 operations at full load 3.4 ounces each PREFERRED SELECTION CATALOG NUMBERS -40 to +70°C ambient, up to 90° interface per ANSI DUX124-12A J50 DUX124-12A J12 Dielectric strength: 5000 V per ANSI UL listed is standard Ordering Information Example: D U X 1 2 4 - 1 2 A J 5 0 Voltage DUX120 120 Volts (105–130) DUX124 120/240/277 Volts (105–305) DUX480 480 Volts (420–530) 1 1.2–3 ftc Turn-on (standard) 2 Silicon Sensor, Time Delay (2-5 seconds) Upward Facing Product Guide A P ANSI Standard* Upward Facing * See chart page 186 DIMENSIONS 180 Cover Color Sensor Turn-on Level (ftc) For more information, visit our website, www.americanelectriclighting.com Job Packs J12 12 Units J50 50 Units D7790 Series Electronic Locking Type Photocontrol O R D E R I N G I N F O R M AT I O N Features: Silicon light sensor Complies with ANSI C136.10-1996 Two-year warranty Standard 190 joule, 4500 amp MOV Polypropylene cover, Neoprene gasket, brass legs, acrylic window Base rated for 120°C Power consumption: 0.5 watts At 120 VAC Load rating: 1000 watts, 1800 VA ballast Sealed relay rated for 5000 operations at full load Instant turn on, 2-5 second turn off Applications: Turn on is 1.5 + 0.5 ftc, turn off is 1.5 times turn on Replacement for many industry standard locking type photoocontrols 3.4 ounces each Available in job packs of J12 or J50 only -40 to +70°C ambient, Up to 90° interface per ANSI PREFERRED SELECTION CATALOG NUMBERS Dielectric strength: 5000 V per ANSI D7790 is a replacement for many industry standard type locking photocontrols D7790 J50 Sealed in individual poly bags Ordering Information Example: D 7 7 9 0 J 5 0 Job Pack Voltage D7790 120/208/240/277 VAC J12 J50 12 Units 50 Units DIMENSIONS Product Guide 181 DD Series Diagnostics Electronic Locking Type Photocontrol O R D E R I N G I N F O R M AT I O N Features: Regular dusk to dawn operation Diagnostic feature detects and disables cycling HPS lamps and lamps that fail to start Extends starting aids life Flashing or steady LED alerts line crew of problem Filtered silicon light sensor 2-5 second off delay MOV surge protection Complies with ANSI C136.10-1996; not for use on incandescent fixtures Six-year warranty Available in job packs of J12 or J50 only Applications: Polypropylene cover, neoprene gasket, brass legs, acrylic window base rated for 120°C Roadway and area lighting High profile installations Anywhere cycling lamps are a problem Anywhere starting aid life is a problem Power consumption: 1.0 watts Load rating: 70-400 watt HPS Sealed relay rated for 5000 operations at full load 3.8 ounces each -40 to +70°C ambient, Up to 90° interface per ANSI Dielectric strength: 5000 V per ANSI Ordering Information Voltage DD124 120/208/240/277 Volts (105-305) Example: D D 1 2 4 - 1 . 5 - T J A J 5 0 1.5 ANSI Standard Cycle Detection1 Time Delay (seconds) Turn-on Level (ftc) T 2-5 Second Turn-off Delay (standard) A After Five Lamp Cycles, Control Turns Lamp Off. Next Dusk, Control Turns Lamp On and Cycle Detection Circuit Restarts Job Packs J12 J50 12 Units 50 Units Surge Protector J DIMENSIONS 320J/10,000 Amp MOV Notes: 1 2 182 Product Guide For more information, visit our website, www.americanelectriclighting.com Available with black cover only Cycle Detection Program is set at factory; program cannot be altered in field DPN Series Part Night Electronic Locking Type Photocontrol O R D E R I N G I N F O R M AT I O N Features: Control turns on at dusk and off halfway through the night. Automatically self-adjusts to seasonal time changes, reducing maintenance Reduces light pollution and light trespass concerns Filtered silicon photocell provides long-term, drift-free light sensing. The infrared blocking polymer filter gives human eye response. A 2-5 second off-time delay is provided to avoid turn-off from extraneous light. Complies with ANSI C136.10-1996 Six-year warranty Energy Savings Available in job packs of J12 or J50 only Polypropylene cover, neoprene gasket, brass legs, acrylic window base rated for 120°C Applications: Power consumption: 0.8 watts Parking lots Area lights Park lights Media lighting Ball fields and courts Pedestrian lighting Load rating: 1000 watts, 1800 VA ballast Sealed relay rated for 5000 operations at full load Turn OFF is at middle of the night. 3.6 ounces each -40 to +70°C ambient, Up to 90° interface per ANSI Dielectric strength: 5000 V per ANSI Ordering Information Example: D P N 1 2 4 - 2 . 6 - T J G N J 5 0 DPN124 Time Delay (seconds) Turn-on Level (ftc)1 Voltage 120/240/277 Volts (105-305) 1.5 2.6 ANSI Standard Standard T Cover Color GN 2-5 Second Turn-off Delay (standard) Job Packs Green (only) J12 12 Units J50 50 Units Surge Protector J 320 J/10,000 Amp MOV DIMENSIONS Notes: 1 Other options available, please contact your local American Electric Lighting representative Product Guide 183 DBE Series Button Electronic Wire-In Photocontrol O R D E R I N G I N F O R M AT I O N Features: Electronic wire-in button photocontrol Instant turn-on, standard 5-10 second turn-off time delay Filtered Silicon light sensor UL listed models available Filtered silicon light sensor Voltages 120–347 Complies with ANSI C136.24 Long life Low maintenance Six-year warranty Applications: Available in job packs of J12 only Park lighting Security lighting Post lanterns Decorative and area lighting 190 Joule MOV surge protection 12”, 200ºC, #16 wire leads PREFERRED SELECTION CATALOG NUMBERS DBE124-1.5-T J12 DBE120-1.5-T J12 Example: D B E 1 2 0 1 . 5 - T J 1 2 Ordering Information Voltage DBE120 DBE240 DBE347 DBE124 Time Delay (seconds) Turn-on Level (ftc) 120 Volts (105–130) 208/240/277 Volts (200–305) 347 Volts (300–400) 120/240/277 Volts (105–305) 1.5 ANSI Standard T 5-10 Second Turn-off Delay (standard) DIMENSIONS 3/8” (18) Straight pipe thread 184 Product Guide For more information, visit our website, www.americanelectriclighting.com Certification (blank) U No Listing CSA and UL Listed Job Pack J12 12 Units Shorting and Open Caps Locking Type O R D E R I N G I N F O R M AT I O N SHORTING AND OPEN CAPS For luminaires where lights are to be on continuously (shorting cap) or left off (open cap). Exceeds ANSI C136.10-1996. Description Catalog Number Shorting cap. Black Cover D-SHORT-SBK Shorting cap 320J. MOV surge protection. Black cover. D-SHORT-VBK Open cap. Red cover. D-OPEN-SRD PREFERRED SELECTION CATALOG NUMBERS D-SHORT-SBK J12 D-SHORT-VBK J12 D-OPEN-SRD J50 DIMENSIONS Product Guide 185 Photocontrol Accessories OA RC DC E RS IS NO GR I IENS F O R M A T I O N Catalog Number Description PHOTOCONTROL RECEPTACLES PREFERRED SELECTION Mounting adapter for connecting photocontrol to net. For pole, CATALOG NUMBER wall and frame mounting. 14” x 14” gage wire. Line = black, Load = red, Neutral = white. Each receptacle meets NEMA DUR-103 J6 and ANSI standards. With bracket and rotating cup with locknut DUR-103 PHOTOCONTROL TESTCAP Lightweight black vinyl cap tests the working operation of photocontrols during daylight hours. Completely eliminates direct and reflected light, enabling quick and easy testing. Not designed for use with hot sticks. Affordably priced. D-TESTCAP ANSI Color Chart Photocontrol Recommendation Chart DTL SERIES Type Voltages Available Light Sensor Surge Protection Application Typical Electronic DP Locking 120 thru 480 Silicon MOV, 320 Joule Roadway Yes DE Locking 120 thru 480 MOV, 320 Joule Roadway Yes DX Locking 120 thru 480 Filtered Silicon Silicon MOV, 320 Joule C&I + Roadway Yes DUX 120 thru 480 Silicon MOV, 320 Joule Yes 120-277 Silicon MOV, 160 Joule Where UL is needed Off-Roadway 120-277 Silicon MOV, 160 Joule Roadway Yes DBE Locking, UL listed Locking, Part Night Locking, Diagnostic Button 120 and 208-277 MOV, 190 Joule Utility post top Yes D7790 Locking 120 thru 347 Filtered Silicon Silicon MOV, 190 Joule Roadway or export Yes DPF Locking, Fail OFF Locking, Inverse Ratio Locking, Reverse 120-277 Silicon MOV, 320 Joule Off-Roadway Yes 120-277 Silicon MOV, 320 Joule Roadway Yes 120-277 Silicon MOV, 320 Joule OFF night, ON day Yes DD DPR DPO 186 Product Guide D-TESTCAP J50 PHOTOCONTROL DEMO BOX Portable 120 volt test box. Dimensions: 51/2 x 3 x 21/2 inches. D-DEMO BOX DPN PREFERRED SELECTION CATALOG NUMBER For more information, visit our website, www.americanelectriclighting.com Yes ANSI Color Codes 120V 240V Multivolt 350V 480V Gray Maroon Dark Blue Green Yellow POLES Illustrated Samples ................................................188 RSA ...........................................................................192 Wind Map ................................................................189 RTA............................................................................193 Florida Wind Rating................................................190 RSAH ........................................................................194 General Information...............................................191 SSA ...........................................................................195 SSAH ........................................................................196 RSS ...........................................................................197 RTS............................................................................198 SSS ...........................................................................199 STS............................................................................200 STSH.........................................................................201 Pole Options ............................................................202 Aluminum Mounting Brackets .............................203 Steel Mounting Brackets ......................................204 RTF ............................................................................205 RTFDB.......................................................................206 SSF............................................................................207 STC............................................................................208 SPRTC.......................................................................209 SPRTS.......................................................................213 RTAU.........................................................................216 RTSU.........................................................................220 AMAW / SMAW / Arms for Wood Poles ............222 AMAC / SMAC / Arms for Concrete Poles .........224 SMAWL / Arms for Wall Mount ...........................226 Traditional Wood Pole Arms.................................228 Traditional Concrete Pole Arms...........................229 American Electric Lighting ® 187 I L L U S T R AT E D S A M P L E S There are several different pole types available throughout this section. Below are a few examples. Please contact your local American Electric Lighting representative for more information. Round Straight Aluminum Round Straight Steel Round Tapered Aluminum Round Tapered Fiberglass 4” Bolt Projection 18” Square Straight Steel Square Straight Aluminum Square Tapered Steel 188 Product Guide For more information please visit our website: www.americanelectriclighting.com Square Tapered Steel Hinge Contact AEL for specific data. W I N D M A P Product Guide 189 F L O R I D A P O L E Steel W I N D R AT I N G C H A R T SIDE-MOUNTED LOAD max. wt. Max WT/EPA Max WT/EPA Max WT/EPA that will be used 130mph Zone 140mph Zone 150mph Zone 100 14.2 / 100 12.1 / 100 10.3 / 100 200 10.9 / 200 9.3 / 200 7.9 / 200 200 12.2 / 200 10.4 / 200 8.9 / 200 225 10.0 / 225 8.2 / 225 6.9 / 225 225 19.3 / 225 16.3 / 225 13.9 / 225 225 9.6 / 225 7.6 / 225 5.9 / 225 225 13.9 / 225 11.4 / 225 9.5 / 225 TENON-MOUNTED LOAD Max WT/EPA Max WT/EPA Max WT/EPA 130mph Zone 140mph Zone 150mph Zone 13.1 / 100 11.2 / 100 9.5 / 100 10.3 / 200 8.7 / 200 7.4 / 200 13.3 / 200 11.3 / 200 9.7 / 200 9.5 / 225 7.9 / 225 6.6 / 225 18.3 / 225 15.5 / 225 13.2 / 225 9.2 / 225 7.3 / 225 5.7 / 225 13.3 / 225 11.0 / 225 9.2 / 225 RTS 20 25 25 30 30 35 39 6-5B 7-0B 7-0F 8-0B 8-0F 9-5B 9-0F SSS 20 25 30 5G 5G 6G 100 100 100 10.7 / 100 5.5 / 100 4.7 / 100 8.5 / 100 3.8 / 100 2.7 / 100 6.7 / 100 2.4 / 100 1.0 / 100 10.0 / 100 5.3 / 100 4.6 / 100 7.9 / 100 3.6 / 100 2.6 / 100 6.2 / 100 2.4 / 100 1.1 / 100 SSA 20 25 6G 6J 100 100 5.8 3.5 0 0 2.4 0 0 0 0 0 0 0 RTA 20 25 30 30 35 7E 8G 8G 10G 10G 100 200 200 225 225 7.5 8.8 5.6 11.4 8 6.4 7.4 4.6 9.4 6.4 5.3 6.2 3.7 7.7 5 7.2 8.5 5.5 11.2 7.9 5.8 6.9 4.3 8.9 6.1 5.1 6 3.7 7.6 4.9 Aluminum 190 Product Guide For more information please visit our website: www.americanelectriclighting.com Poles General Information Poles are available only in US O R D E R I N G I N F O R M AT I O N Example: S S A 1 6 4 G D M 1 9 D D B A E L Shaft type RTA RSA RSAH SSA SSAH RTS STS STSH RSS SSS SSF RTF RTFDB SPRTC STC SPRTS Nominal shaft base size/wall thickness (in.) Round Tapered Aluminum Round Straight Aluminum 3 B 0.120 Round Straight Aluminum Hinged 4 C 0.125 Square Straight Aluminum 5 E 0.156 Square Straight Aluminum Hinged 6 G 0.188 Round Tapered Steel 7 J 0.250 Square Tapered Steel 8 K 0.312 Square Tapered Steel Hinged 9 L 0.219 Round Straight Steel 10 P 0.375 Square Straight Steel Square Straight Fiberglass Nominal mounting height Round Tapered Fiberglass Round Tapered Fiberglass 8–50 feet Sportslighting Poles Direct Burial up to 115 Feet Round Tapered Concrete See website for specific Sportslighting information. Square Tapered Concrete Round Tapered Steel Sportslighting NOTES: 1 Other colors available, please contact your local American Electric Lighting representative. 2 Aluminum poles only. Options Fixture Mounting Method Only Open-top Pole Accepts KKS (4" square) and KKR (4-1/2" round) Luminaires Tenon Mounting T20 2-3/8" O.D. (2" NPS) T25 2-7/8" O.D. (2-1/2" NPS) T30 3-1/2" O.D. (3" NPS) T35 4" O.D. (3-1/2" NPS) Drill Mounting DM19 1 at 90° DM28 2 at 180° DM29 2 at 90° DM39 3 at 90° DM49 4 at 90° DM32 3 at 120° (Round Poles) See Page Architectural Colors1 Polyester Powder 202 Standard Colors DDB Dark bronze DWH White DBL Black BA Brushed Aluminum2 PT Ordering Information: Finish Drill Mounting (blank) A B C D E Class 1 Architectural Anodize (Aluminum only) ABL Black ADB Dark bronze ANA Natural ASA & AVL Sq Pole 53 Sq Pole 153 Sq Pole LS, LM, LL Rd Pole 53 & 153 AVL w/A4 Option Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option All luminaire/pole assemblies require proper evaluation to ensure that the structural integrity of the assembly is not compromised when applied in specific wind conditions. Therefore, the basis for pole selection in this catalog is total weight and effective projected area, EPA (ft2), shown on the individual pole catalog pages. Determination of maximum EPA (ft2) and weight loading must include all luminaires, bracketry, signs, decorations, overhead wires or other equipment that will be mounted to the subject pole. Luminaire EPA (ft2) and weight data are found on their respective product pages. The total effective projected area of the luminaires and brackets shall not exceed the EPA (ft2) listed for the pole selected at a given wind velocity. Poles that are to be located in areas of known abnormal conditions will require special consideration. The map on page 189 gives the wind velocities to be used in determining luminaire pole compatibility. Note: If during the pole warranty period of one year, the product proves defective in material or workmanship, the company shall correct, at its option, by repairing or replacing at no charge to the purchaser, if the purchaser promptly notifies the company. This warranty specifically excludes fatigue failure or similar phenomena resulting from induced vibration harmonic oscillation or resonance associated with the movement of air currents around the product. Pole Selection Procedure Step 1. Select the luminaire and decide how many will be mounted per pole. Determine the Effective Projected Area, EPA (ft2), which is given on the dimensional information table. Step 2. Determine the appropriate mounting method for the luminaire. Options include arm, bracket or tenon mounting. Step 3. Add together the EPA's (ft2) of the luminaire and arm/bracket. Multiply by number of fixtures to be mounted on one pole. Step 4. Consult the Wind Map on page 189 to determine the basic wind velocity for your area. Step 5. Select the material (steel or aluminum) and shape (square or round) of the pole. Refer to the “Technical Information” chart on the appropriate pole page. A. Find the desired nominal mounting height in the second column. B. Verify that the fixture weight does not exceed the maximum weight listed for the desired pole. C. Compare your total EPA (ft2) loading with the maximum EPA (ft2) value found in the wind speed column for your area. Check that the equipment you are using will not exceed this value. D. If both the weight and EPA (ft2) values do not exceed the values for which the pole is rated, you have selected the correct pole. If, however, either one of those numbers exceeds the maximum rated values, compare the EPA (ft2) and fixture weight loads to the next larger pole of the same mounting height. CAUTION: This pole selection process is a guideline only. American Electric Lighting assumes no responsibility for selection and recommends consultation with qualified individuals for verification of luminaire/pole assembly selection. Pole Data1 4 Bolt Base 3 Bolt Base Shaft Base size Bolt circle A Bolt projection B Base square C Warehouse Anchor Bolt description Template number 4" 4-1/2" 5" 6" 3" 4" 5” 6-1/2"–8-1/4" 7–8-1/2" 7-1/2"–9-1/2" 8-3/4"–10-1/4" 5-1/2"–7" 6-5/16”–7-3/8" 7-3/8"–8-1/2" 3-1/4" 3-1/4" 3-1/4" 3-1/2" 4-1/8" 4-1/4" 4-1/2" 8-3/4" 8-1/2" 9-1/4" 10-1/4" 10-1/2" 11-1/2" 14-1/2" AB18-0 AB18-0 AB18-0 AB30-0 AB36-0 AB36-0 N/A PJ50057 PJ50040 PJ50058 PJ50059 PJ50125 PJ50126 PJ50127 1 Pole Data for RSA, page 192 Product Guide 191 RSA Anchor Base Poles Round Straight Aluminum P R O D U C T O V E R V I E W Intended Use For 8’ to 30’ mounting height. Grounding – Ground lug located immediately inside handhole is tapped for ground bolt (not supplied by others). Features: Shaft – One-piece extruded 6063-T6 aluminum alloy with T6 temper. Circumferential satin-brushed finish. 4 1/2" round straight tube is uniform in cross-section down length of shaft. Handhole – A nominal 2” x 4” or 3” x 5” reinforced handhole is centered 18” above the base. Cover and attachment hardware furnished. Hardware – Stainless steel. Anchor Base – Cast from A356 aluminum alloy and heat treated to T6 temper. Base slipfits shaft, and they are joined together by continuous circumferential welds at both top and bottom of anchor base to provide maximum strength at area of critical stress. Top Cap – Cast-aluminum cap is provided for drill-mount poles. Anchor Bolts – Top 12" is galvanized per ASTM A-153. Made of carbon steel bar with a minimum-yield strength of 55,000 psi. Bolt Covers – A356 nut covers included with anchor base unless otherwise specified. Finish – Standard finish is brushed aluminum. Optional polyester powder paint and anodized finishes available. Ordering Information: See page 191 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factorysupplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately upon delivery to prevent finish damage. Catalog Number 4 Bolt Base RSA 8 4C RSA 10 4C RSA 12 4C RSA 14 4C RSA 14 4-5C RSA 14 5C RSA 16 4C RSA 16 4-5C RSA 16 4-5G RSA 16 5C RSA 16 5E RSA 18 4-5G RSA 18 5C RSA 18 5E RSA 18 5G RSA 20 4-5G RSA 20 5C RSA 20 5E RSA 20 5G RSA 20 6E RSA 25 4-5G RSA 25 6E RSA 25 6G RSA 30 6G 3 Bolt Base 3RSA 8 3C 3RSA 10 3C 3RSA 10 4C 3RSA 12 3C 3RSA 12 4C 3RSA 12 5C 3RSA 14 3C 3RSA 14 4C 3RSA 14 5C 3RSA 16 4C 3RSA 16 5E 3RSA 18 5C 3RSA 20 5C 3RSA 20 5E Nom. Pole Wall mount. Shaft Size Thick. ht. (ft.) (in. dia. x ft.) (in.) 80 mph 90 mph 100 mph Max. wt. Bolt Circle (in.) 8 10 12 14 14 14 16 16 16 16 16 18 18 18 18 20 20 20 20 20 25 25 25 30 4.0 x 8.0 4.0 x 10.0 4.0 x 12.0 4.0 x 14.0 4.5 x 14.0 5.0 x 14.0 4.0 x 16.0 4.5 x 16.0 4.5 x 16.0 5.0 x 16.0 5.0 x 16.0 4.5 x 18.0 5.0 x 18.0 5.0 x 18.0 5.0 x 18.0 4.5 x 20.0 5.0 x 20.0 5.0 x 20.0 5.0 x 20.0 6.0 x 20.0 4.5 x 25.0 6.0 x 25.0 6.0 x 25.0 6.0 x 30.0 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.188 0.125 0.156 0.188 0.125 0.156 0.188 0.188 0.125 0.156 0.188 0.156 0.188 0.156 0.188 0.188 11.2 8.2 6.0 4.1 5.8 7.8 2.8 4.2 7.5 5.9 8.0 5.7 4.3 6.1 8.0 4.3 3.0 4.7 6.4 9.3 1.3 5.2 7.1 3.5 8.6 6.1 4.3 2.8 4.2 6.0 1.6 2.8 5.5 4.4 6.1 4.0 3.1 4.6 6.8 2.9 2.1 3.4 4.8 7.1 — 3.8 5.3 2.4 6.8 4.7 3.2 1.9 3.3 4.7 1.0 2.1 4.3 3.4 4.8 3.1 2.4 3.5 4.7 2.1 1.5 2.6 3.6 5.5 — 2.8 4.0 1.6 125 100 110 75 60 100 150 50 155 175 190 123 150 175 225 95 150 150 150 175 100 150 150 200 6-1/2-8-1/4 6-1/2-8-1/4 6-1/2-8-1/4 6-1/2-8-1/4 7-1/8-8-3/8 7-1/2-9-1/2 6-1/2-8-1/2 7-1/8-8-3/8 7-1/8-8-3/8 7-1/2-9-1/2 7-1/2-9-1/2 7-1/8-8-3/8 7-1/2-9-1/2 7-1/2-9-1/2 7-1/2-9-1/2 7-1/8-8-3/8 7-1/2-9-1/2 7-1/2-9-1/2 7-1/2-9-1/2 8-3/4-10-1/4 7-1/8-8-3/8 8-3/4-10-1/4 8-3/4-10-1/4 8-3/4-10-1/4 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 22 26 30 35 42 39 38 46 62 46 53 68 48 58 68 74 54 68 82 95 89 108 128 146 8 10 10 12 12 12 14 14 14 16 16 18 20 20 3.0 x 8.0 3.0 x 10.0 4.0 x 10.0 3.0 x 12.0 4.0 x 12.0 5.0 x 12.0 3.0 x 14.0 4.0 x 14.0 5.0 x 14.0 4.0 x 16.0 5.0 x 16.0 5.0 x 18.0 5.0 x 20.0 5.0 x 20.0 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.156 0.125 0.125 0.156 5.8 4.0 8.2 2.7 5.8 10.3 1.7 4.1 7.9 2.8 8.0 4.3 2.9 4.6 4.3 2.9 6.1 1.8 4.2 8 1.0 2.8 6.0 1.6 6.1 3.1 2.0 3.3 3.3 2.3 4.7 1.2 3.1 6.3 0 1.9 4.7 1.0 4.8 2.4 1.4 2.5 75 75 75 75 150 150 75 150 150 150 150 150 150 150 5-1/2-7 5-1/2-7 6-5/16-7-3/8 5-1/2-7 6-5/16-7-3/8 7-3/8-8-1/2 5-1/2-7 6-5/16-7-3/8 7-3/8-8-1/2 6-5/16-7-3/8 7-3/8-8-1/2 7-3/8-8-1/2 7-3/8-8-1/2 7-3/8-8-1/2 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 22 26 26 30 30 36 35 35 39 38 53 48 54 68 NOTES: For Pole Data Chart, see page 191 192 Product Guide Bolt Approx. Size ship wt. (in. x in. x in.) (lbs.) For more information please visit our website: www.americanelectriclighting.com RTA Anchor Based Poles Round Tapered Aluminum P R O D U C T O V E R V I E W Intended Use For 20’ to 39’ mounting height. Grounding – A ground lug located immediately inside the handhole is tapped for 3/8”-16 UNC ground bolt (by others). Features Handhole – A nominal 3"x5" or 4"x6" reinforced flush covered handhole is centered 18" above the base. Shaft – The shaft is spun tapered from seamless 6063 alloy aluminum tubing and is heat-treated to produce a T6 temper. The shaft is cone tapered to the butt diameter. Hardware – Stainless steel. Anchor Base – Cast from A356 alloy aluminum, the anchor base is heat-treated to a T6 condition. The anchor base telescopes the pole shaft and is circumferentially welded top and bottom. Top Cap – Cast-aluminum cap is provided for drill mount poles. Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of steel rod having a minimum yield strength of 55,000 PSI. Bolt Covers – A356 nut covers shall be included with each anchor base unless otherwise specified. Finish – Standard finish is brushed aluminum. Optional polyester powder paint and anodized finishes available. Ordering Information: See page 191 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust Catalog Number 4 Bolt Base RTA 20 5C RTA 20 5G RTA 20 6G RTA 20 7E RTA 25 6E RTA 25 7E RTA 25 8E RTA 25 8G RTA 30 7E RTA 30 8E RTA 30 8G RTA 30 10G RTA 35 8E RTA 35 8G RTA 35 8J RTA 35 10G RTA 39 8G RTA 39 8J RTA 39 10G RTA 39 10J 3 Bolt Base 3RTA 8 4C 3RTA 10 4C 3RTA 12 4C 3RTA 14 4C 3RTA 16 4C 3RTA 16 5C 3RTA 18 5C 3RTA 18 5E 3RTA 20 5C 3RTA 20 5E Nom. Pole Wall mount Shaft Size Thickness 80 ht. (ft.) (in. x in. x ft.) (in.) mph 20 20 20 20 25 25 25 25 30 30 30 30 35 35 35 35 39 39 39 39 5 x 3 x 19’8” 5 x 3 x 19’8” 6 x 4 x 19’8” 7 x 4 x 19’8” 6 x 4 x 24’ 8” 7 x 4 x 24’8” 8 x 4.5 x 24’ 8” 8 x 4.5 x 24’ 8” 7 x 4 x 29’8” 8 x 4.5 x 29’8” 8 x 4.5 x 29’8” 10 x 6 x 29’8” 8 x 4.5 x 34’8” 8 x 4.5 x 34’8” 8 x 4.5 x 34’8” 10 x 6 x 34’8” 8 x 4.5 x 38’8” 8 x 4.5 x 38’8” 10 x 6 x 38’8” 10 x 6 x 38’8” 8 10 12 14 16 16 18 18 20 20 4.0 x 8.0 4.0 x 10.0 4.0 x 12.0 4.0 x 14.0 4.0 x 16.0 5.0 x 16.0 5.0 x 18.0 5.0 x 18.0 5.0 x 20.0 5.0 x 20.0 0.125 0.188 0.188 0.156 0.156 0.156 0.156 0.188 0.156 0.156 0.188 0.188 0.156 0.188 0.250 0.188 0.188 0.250 0.188 0.250 0.125 0.125 0.125 0.125 0.125 0.125 0.125 0.156 0.125 0.156 Approx Bolt Circle Bolt Size ship wt. (in.) (in. x in. x in.) (lbs.) 90 mph 100 mph Max. wt. 3.9 7.4 12.2 15.0 5.3 9.5 14.2 18.0 5.5 9.4 12.4 23.8 5.8 8.3 12.9 17.9 5.6 9.7 14.2 20.4 2.5 5.2 9.2 11.4 3.6 7.0 10.9 13.8 3.8 7.0 9.4 18.3 4.1 6.0 9.7 13.6 3.9 7.1 10.5 15.5 1.6 3.8 7.2 9.0 2.6 5.4 8.5 10.9 2.7 5.3 7.3 14.3 2.9 4.5 7.5 10.4 2.7 5.4 7.8 11.9 100 100 214 256 114 162 220 261 111 151 179 377 119 141 183 295 122 158 253 300 7-1/2-9-1/2 7-1/2-9-1/2 9–10 9-7/8-11-1/4 9–10 9-7/8-11-1/4 11–12 11–12 9-7/8-11-1/4 11–12 11–12 14-1/4-16-1/4 11–12 11–12 11–12 14-1/4-16-1/4 11–12 11–12 14-1/4-16-1/4 14-1/2-16 12.1 8.8 6.6 4.9 3.5 6.9 5.0 7.0 3.8 5.5 9.3 6.7 4.8 3.4 2.3 5.0 3.5 5.0 2.5 3.8 7.3 5.2 3.6 2.4 1.5 3.8 2.5 3.7 1.6 2.6 75 75 75 75 75 75 150 150 150 150 6-1/2–7-1/4 6-1/2–7-1/4 6-1/2–7-1/4 6-1/2–7-1/4 6-1/2–7-1/4 7-1/2-8-1/2 7-1/2-8-1/2 7-1/2-8-1/2 7-1/2-8-1/2 7-1/2-8-1/2 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 1 x 36 x 4 3/4 x 30 x 3 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 40 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 40 x 4 1 x 36 x 4 1 x 36 x 4 1 x 40 x 4 1-1/4 x 48 x 5 62 72 107 103 106 120 130 153 135 150 175 235 185 220 251 268 250 280 295 373 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 n/a n/a n/a n/a n/a n/a n/a n/a 62 70 INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately upon delivery to prevent finish damage. NOTES: • Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) • Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° • Options: See page 202 • Brackets: See page 203-204 18” Pole Data 4 Bolt Base 3 Bolt Base Shaft Base size Bolt circle A Bolt projection B Base square C Anchor Bolt description Warehouse Anchor Bolt description Template number 5" 6" 7" 8" 10"G 10"J 4" 5" 7-1/2"–9-1/2" 9"–10" 9-7/8"–11-1/4" 11-12" 14-1/4"–16-1/4" 14-1/2"–16" 6-1/2"–7-1/4" 7-1/2"–8-1/2" 3-1/4" 3-1/2" 4-1/8" 4-1/4" 4-1/2" 5" 3-1/4" 3-1/4" 9-1/4" 10" 10-1/2" 11-1/2" 14-1/2" 14-1/2" 8-7/8" 10-1/4" ABRTA-5 ABRTA-6 ABRTA-7 ABRTA-8 ABRTA-10G ABRTA-10J ABRTA-5 ABRTA-5 AB18-0 AB30-0 AB36-0 AB36-0 N/A N/A AB18-0 AB18-0 PJ50032 PJ50033 PJ50034 PJ50035 PJ50036 PJ50063 PJ50128 PJ50129 Product Guide 193 RSAH Anchor Base Poles Round Straight Aluminum, Hinged P R O D U C T O V E R V I E W Intended Use For 10’ to 20’ mounting height. Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of carbon steel bar having a minimum-yield strength of 55,000 PSI. Features Grounding – Base plate tapped for 3/8”-16 UNC ground bolt (provided by others). Shaft – One-piece extruded 6063 aluminum alloy with a T6 temper. Circumferential satin-brushed finish. The round, straight tube is uniform in cross-section down the length of the shaft. Handhole – Available as an option, and located 90o to the right of the hinge. Hinged Anchor Base – Cast from A356 aluminum alloy, the anchor base is heat-treated to a T6 temper. The shaft inserts into the tilting section of the hinged base and is joined together by continuous circumferential welds at the outside top and inside bottom. The tilting and anchored sections of the hinged base are joined by a 3/4" diameter solid aluminum pivot rod. The tilting section of the hinged base is held in a vertical position by three 1/2”"-13 x 2 1/2" stainless steel hex head bolts which attach to stainless steel inserts cast into the aluminum base. A cast-aluminum two-piece cover is included. Hardware – Stainless steel. Top Cap – Removable cast-aluminum top cap is provided for drill mount poles. Finish – Standard finish is brushed aluminum. Optional polyester powder painted and anodized finishes available. Ordering Information: See page 191 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately upon delivery to prevent finish damage. Catalog Number RSAH 10 4C RSAH 14 4C RSAH 14 5E RSAH 16 4C RSAH 16 5C RSAH 16 6E RSAH 18 5C RSAH 18 5G RSAH 20 5C RSAH 20 5G RSAH 20 6G Nom. Pole Wall mount. Shaft Size Thick. ht. (ft.) (in. x in. x ft.) (in.) 10 14 14 16 16 16 18 18 20 20 20 4 x 4 x 10 4 x 4 x 14 5 x 5 x 14 4 x 4 x 16 5 x 5 x 16 6 x 6 x 16 5 x 5 x 18 5 x 5 x 18 5 x 5 x 20 5 x 5 x 20 6 x 6 x 20 0.125 0.125 0.156 0.125 0.125 0.156 0.125 0.188 0.125 0.188 0.188 80 mph 90 mph 100 mph Max. wt. Bolt Circle (in.) 8.2 4.4 10.6 3.1 6.2 13.8 4.5 8.2 3.2 6.4 11.7 6.1 3.0 8.2 1.9 4.7 10.7 3.3 6.2 2.2 4.8 9.0 4.7 2.1 6.5 1.2 3.6 8.5 2.5 4.9 1.6 3.7 7.1 100 100 100 100 100 100 130 130 130 130 130 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 Bolt Approx. Size ship wt. (in. x in. x in.) (lbs) 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 NOTES: • Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) • Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° • Options: See page 202 • Brackets: See page 203-204 Pole Data Tapped 3/8” - 16 for ground connector 194 Product Guide Shaft Base size Bolt circle A Bolt projection B Base square C Warehouse Anchor Bolt description Template number 4" 5" 6" 8-1/2"–10" 8-1/2"–10" 8-1/2"–10" 3-1/2" 3-1/2" 3-1/2" 12-5/8" 12-5/8" 12-5/8" AB18-0 AB18-0 AB30-0 PJ50060 PJ50061 PJ50062 For more information please visit our website: www.americanelectriclighting.com 43 50 66 54 60 88 65 90 69 97 110 SSA Anchor Base Poles Square Straight Aluminum P R O D U C T O V E R V I E W Intended Use For 4’, 5’ or 6’ shaft width, 8’ to 35’ mounting height. Grounding – Ground lug located immediately inside handhole is tapped for 3/8"-16 UNC ground bolt (provided by others). Features Shaft – Square, non-tapered shaft made from extruded 6063-T6 or 6061-T6 aluminum alloy Shaft width is 4, 5 or 6 inches. Wall thickness is .125, .188 or .250, depending on mounting height and loading requirements. Anchor Base – Cast from 356-T6 aluminum alloy. Anchor bolt holes are recessed and covered by aluminum caps. Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 3/4" or 1" diameter steel rod having minimum-yield strength of 55,000 psi. Handhole – Reinforced handhole having nominal dimensions 2" x 4" (4" sq.) or 2 1/2” x 4" (5" or 6" sq.). Handhole cover plate made from aluminum alloy with attachment hardware provided. Hardware – Stainless steel. Top Cap – Removable cast-aluminum top cap is provided for drill mount poles. Finish – Brushed aluminum is standard; optional polyester powder paint and anodized finishes available. Bolt Covers – Nut covers included with each anchor base. Ordering Information: See page 191 (Note: Poles are available only in U.S.) Technical Information EPA (ft ) with 1.3 gust 2 Catalog Number SSA 8 4C SSA 10 4C SSA 12 4C SSA 14 4C SSA 15 4C SSA 16 4C SSA 16 4G SSA 16 5G SSA 18 4C SSA 18 4G SSA 18 5G SSA 20 4C SSA 20 4G SSA 20 5G SSA 20 6G SSA 20 6J SSA 25 5G SSA 25 6G SSA 25 6J SSA 30 6G SSA 30 6J SSA 32 6J SSA 35 6J SSA 35 7J Nom. Pole Wall mount. Shaft Size Thick. ht. (ft.) (in. x in. x ft.) (in.) 8 10 12 14 15 16 16 16 18 18 18 20 20 20 20 20 25 25 25 30 30 32 35 35 4.0 x 8.0 4.0 x 10.0 4.0 x 12.0 4.0 x 14.0 4.0 x 15.0 4.0 x 16.0 4.0 x 16.0 5.0 x 16.0 4.0 x 18.0 4.0 x 18.0 5.0 x 18.0 4.0 x 20.0 4.0 x 20.0 5.0 x 20.0 6.0 x 20.0 6.0 x 20.0 5.0 x 25.0 6.0 x 25.0 6.0 x 25.0 6.0 x 30.0 6.0 x 30.0 6.0 x 32.0 6.0 x 35.0 6.0 x 35.0 0.125 0.125 0.125 0.125 0.125 0.125 0.188 0.188 0.125 0.188 0.188 0.125 0.188 0.188 0.188 0.250 0.188 0.188 0.250 0.188 0.250 0.250 0.250 0.250 80 mph 90 mph 100 mph Max. wt. Bolt Circle (in.) 16.5 11.5 12.4 9.3 8.0 6.9 11.8 15.0 4.9 9.2 16.8 3.3 7.0 13.6 22.0 30.4 7.2 13.2 19.7 7.0 12.2 9.7 6.4 7.6 12.6 8.6 9.2 6.7 5.6 4.7 8.5 11.1 3.0 6.4 12.2 1.7 4.6 9.5 15.9 22.6 4.2 8.6 13.8 3.4 7.5 5.4 2.6 3.1 9.9 6.5 6.9 4.8 3.9 3.1 6.2 7.5 1.7 4.4 8.9 0.5 2.9 6.6 11.6 17.0 2.0 5.4 9.5 0.8 4.1 2.3 — — 300 230 160 120 100 90 130 280 70 100 230 40 80 180 230 300 110 180 250 130 170 160 200 150 8-1/2-9-5/8 8-1/2-9-5/8 8-1/2-9-5/8 8-1/2-9-5/8 8-1/2-9-5/8 8-1/2-9-5/8 8-1/2-9-5/8 10-1/2-11-1/2 8-1/2-9-5/8 8-1/2-9-5/8 10-1/2-11-1/2 8-1/2-9-5/8 8-1/2-9-5/8 10-1/2-11-1/2 12-13 12-13 10-1/2-11-1/2 12-13 12-13 12-13 12-13 12-13 12-13 14-1/8–15-1/8 Bolt Approx. Size ship wt. (in. x in. x in.) (lbs.) 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 30 x 3 1 x 36 x 4 1 x 36 x 4 3/4 x 30 x 3 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 32 37 40 50 52 54 74 83 57 80 91 62 85 107 155 202 130 180 224 210 258 272 294 290 INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately upon delivery to prevent finish damage. Tapered 3/8”-16 for ground connector NOTES: • Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) • Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° • Options: See page 202 • Brackets: See page 203-204 Pole Data ShaftBolt Base size Bolt circle A Base projection B Anchor square C Anchor Bolt description Template number 4"C 4"G 5" 6" 7" 8-1/2–9-5/8" 8-1/2–9-5/8" 10-1/2–11-1/2" 12"-13" 14-1/8–15-1/8" 3-1/8" 3-1/8" 3-1/4" 4" 4-1/4" 9-15/16" 9-15/16" 11-9/16" 12-1/4" 15-1/8" AB18-0 AB30-0 AB30-0 AB36-0 AB36-0 PJ50045 PJ50045 PJ50046 PJ50044 PJ50130 Product Guide 195 SSAH Anchor Base Poles Square Straight Aluminum, Hinged P R O D U C T O V E R V I E W Intended Use Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 3/4” diameter steel rod having minimum-yield strength of 55,000 psi. For 10’ to 20’ mounting height. Features Grounding – Base plate tapped for 3/8”-16 UNC ground bolt (provided by others). Shaft – Square, non-tapered shaft made from extruded 6063-T6 aluminum alloy. Shaft width is 4 or 5 inches. Wall thickness is .125 or .188 depending on mounting height and loading requirements. Handhole – Available as an option, and located 90o to the right of the hinge. Hinged Anchor Base – Cast from A356 aluminum alloy and heat treated to a T6 temper. The shaft inserts into the tilting section of the hinged base and is joined together by continuous circumferential welds at the outside top and inside bottom. The tilting and anchored sections of the hinged base is held in a vertical position by three 1/2"–13 x 2 1/2" stainless steel hex head bolts which attach to stainless steel inserts cast into the aluminum base. A cast-aluminum two-piece cover is included. Hardware – Stainless steel. Top Cap – Removable cast-aluminum top cap is provided for drill mount poles. Finish – Brushed aluminum is standard; optional polyester powder paint and anodized finishes available. Ordering Information: See page 191 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately upon delivery to prevent finish damage. Catalog Number SSAH 10 4C SSAH 12 4C SSAH 14 4C SSAH 15 4C SSAH 16 4C SSAH 16 4G SSAH 18 4C SSAH 18 4G SSAH 18 5G SSAH 20 4G SSAH 20 5G Nom. Pole Wall mount. Shaft Size Thick. ht. (ft.) (in. x in. x ft.) (in.) 10 12 14 15 16 16 18 18 18 20 20 4 x 4 x 10 4 x 4 x 12 4 x 4 x 14 4 x 4 x 15 4 x 4 x 16 4 x 4 x 16 4 x 4 x 18 4 x 4 x 18 5 x 5 x 18 4 x 4 x 20 5 x 5 x 20 0.125 0.125 0.125 0.125 0.125 0.188 0.125 0.188 0.188 0.188 0.188 80 mph 90 mph 100 mph Max. wt. Bolt Circle (in.) 13.1 9.6 7.0 6.0 5.0 8.9 3.4 6.8 12.6 5.0 9.9 9.9 7.0 4.9 4.0 3.2 6.2 1.8 4.5 8.8 3.0 6.6 7.5 5.1 3.3 2.6 1.9 4.3 0.7 2.9 6.1 1.6 4.2 100 100 100 100 100 150 100 100 150 150 175 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 8-1/2-10 9-5/16-10 8-1/2-10 9-5/16-10 Bolt Approx. Size ship wt. (in. x in. x in.) (lbs.) 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 18 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 NOTES: • Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) • Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° • Options: See page 202 • Brackets: See page 203-204 Pole Data 196 Product Guide Shaft Base size Bolt circle A Bolt projection B Base square C Warehouse Anchor Bolt description Template number 4"C 4"G 5" 8-1/2–10" 8-1/2–10" 9-5/16–10" 3-1/2" 3-1/2" 3-1/2" 11-11/16" 11-11/16" 11-11/16" AB18-0 AB30-0 AB30-0 PJ50055 PJ50055 PJ50056 For more information please visit our website: www.americanelectriclighting.com 48 53 57 60 62 86 67 93 108 100 117 RSS Anchor Base Poles Round Straight Steel P R O D U C T Intended Use O V E R V I E W Anchor Bolts – Top 12" is fully galvanized per ASTM A-153. Made of carbon steel bar with minimum-yield strength of 55,000 psi. For 8’ to 30’ mounting height. Grounding – Nut holder located immediately inside handhole is provided with 1/2”-13 UNC ground bolt and nut. Features Handhole – Nominal 2.5" x 5" handhole is located 18" above base. Cover and attachment hardware provided. Shaft – Weldable grade A500 or A513 carbon steel tubing with minimum yield of 46,000 or 42,000 psi. Uniform wall thickness of .120". Shafts are one-piece construction with a full length longitudinal, high frequency electric resistance weld. The round, straight tube is uniform in crosssection down length of shaft. Hardware – Fasteners are high-strength galvanized or zinc-plated or stainless steel. Top Cap – Removable plastic top cap is provided for drill mount poles. Anchor Base – Fabricated from carbon steel plate (ASTM A-36). 3/4" thickness. Base plate and shaft are circumferentially welded at both top and bottom to provide maximum strength at area of critical stress. Finish – Dark bronze polyester powder paint (DDB) standard; optional polyester powder paint finishes available. Base Cover – Full-base cover finished to match pole. Ordering Information: See page 191 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust Catalog Number RSS 8 4-5B RSS 8 4-5B RSS 10 3B RSS 10 4B RSS 10 4-5B RSS 12 3B RSS 12 4B RSS 12 4-5B RSS 14 3B RSS 14 4B RSS 14 4-5B RSS 15 4-5B RSS 16 3B RSS 16 4B RSS 16 4-5B RSS 18 3B RSS 18 4B RSS 18 4-5B RSS 20 3B RSS 20 4B RSS 20 4-5B RSS 20 5B RSS 22 4-5B RSS 25 4B RSS 25 4-5B RSS 25 5B RSS 30 4-5B RSS 30 5B Nom. Pole Wall mount. Shaft Size Thick. ht. (ft.) (in. x in. x ft.) (in.) 8 8 10 10 10 12 12 12 14 14 14 15 16 16 16 18 18 18 20 20 20 20 22 25 25 25 30 30 4.5 x 8.0 4.5 x 8.0 3.0 x 10.0 4.0 x 10.0 4.5 x 10.0 3.0 x 12.0 4.0 x 12.0 4.5 x 12.0 3.0 x 14.0 4.0 x 14.0 4.5 x 14.0 4.5 x 15.0 3.0 x 16.0 4.0 x 16.0 4.5 x 16.0 3.0 x 18.0 4.0 x 18.0 4.5 x 18.0 3.0 x 20.0 4.0 x 20.0 4.5 x 20.0 5.0 x 20.0 4.5 x 22.0 4.0 x 25.0 4.0 x 25.0 5.0 x 25.0 4.5 x 30.0 5.0 x 30.0 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 80 mph Max. wt. 90 mph Max. wt. 100 mph Max. wt. 24.7 24.5 10 19.1 24.5 7.7 15.0 19.8 6.0 12.2 16.2 12.0 4.6 9.6 13.1 3.4 7.6 10.5 2.4 6.0 8.5 11.75 6.0 2.85 4.8 7.25 2.3 4.2 630 615 250 480 615 195 390 495 175 305 405 300 125 250 330 90 190 265 100 150 215 300 150 100 130 180 80 150 19.7 19.5 7.7 15.0 19.5 5.8 11.8 15.7 4.4 9.4 12.8 9.5 3.2 7.4 10.2 2.3 5.7 8.2 1.4 4.45 6.6 9.1 4.5 1.95 3.6 5.5 1.5 3 495 490 190 375 490 145 300 395 130 250 320 250 100 185 265 60 180 210 75 150 165 230 125 75 90 150 75 125 16.0 15.8 6.0 12.2 15.8 4.4 9.5 12.7 3.3 7.6 10.3 7.5 2.3 5.9 8.2 1.4 4.5 6.5 — 3.45 5.2 7.25 3.75 1.35 2.7 4.25 1.0 2.25 430 395 175 305 395 130 240 320 90 195 260 200 60 150 205 70 130 165 — 125 130 180 100 75 90 150 60 100 Bolt Bolt Approx. Circle Size ship wt. (in.) (in. x in. x in.) (lbs.) 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 55 55 55 70 75 60 80 85 70 90 95 96 80 100 105 90 110 115 100 120 130 145 134 145 145 180 185 210 Nut Holder Handhole Cover INSTALLATION NOTES: Pole Data Shaft Base size Bolt circle A Bolt projection B Base square C Warehouse Anchor Bolt description Template number 3 4" 4-1/2" 5" 8" 8" 8" 8" 3-1/4" x 3-1/2" 3-1/4" x 3-1/2" 3-1/4" x 3-1/2" 3-1/4" x 3-1/2" 8" 8" 8" 8" AB18-0 AB18-0 AB18-0 AB18-0 PJ50041 PJ50041 PJ50041 PJ50041 NOTES: • Mounting Arrangement: (PT) Open Top (T20) 2-3/8" O.D. (2" NPS) • Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately upon delivery to prevent finish damage. 3 Options: see page 202 4 Brackets: See page 203-204 Product Guide 197 RTS Anchor Base Poles Round Tapered Steel P R O D U C T O V E R V I E W Intended Use For 20’ to 50’ mounting height. Grounding – Nut holder located immediately inside handhole is provided with 1/2”-13 UNC ground bolt and nut. Features Shaft – Minimum weldable-grade (ASTM A-595 Grade A), hot-rolled, commercial-quality carbon steel tubing with minimum yield of 55,000 psi. Uniform wall thickness of 11-gauge (0.1196") or 7-gauge (0.1793"). Shafts are constructed with full-length, longitudinal, high-frequency resistance weld. Round in cross-section, having uniform taper of approximately .14" per foot. Anchor Base – Fabricated from hot-rolled carbon steel plate that conforms to ASTM A36. Handhole – Reinforced handhole rim having nominal dimensions of 3"x5" for shafts less than 6.25" base diameter and 4"x6.5" for all other shafts. Steel cover with attachment screws included. Handhole is located 18" above base. Ordering Information: See page 191 (Note: Poles are available only in U.S.) INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately upon delivery to prevent finish damage. Anchor Bolts – Fabricated from commercial-quality hot-rolled carbon steel with minimum yield strength of 55,000 psi. Bolts have an "L" bend on one end. Hardware – Fasteners are high-strength galvanized or zinc-plated or stainless steel. Top Cap – Removable top cap provided with all drill-mount poles. Finish – Dark bronze polyester powder finish (DDB) standard; other architectural colors available. Bolt Cover – Bolt covers are zinc diecast and fasten to shaft by a .25” stainless steel, self tapping hexhead screw. Full base cover available as option. Technical Information EPA (ft2) with 1.3 gust Nom. Pole Wall mount. Shaft Size Thick. ht. (ft.) (in. x in. x ft.) (in.) Catalog Number RTS 20 5-9B RTS 20 6-5B RTS 25 5-9B RTS 25 7-0B RTS 25 7-0F RTS 30 6-6B RTS 30 8-0B RTS 30 8-0F RTS 35 7-3B RTS 35 8-5B RTS 35 9-5B RTS 39 7-8B RTS 39 9-0B RTS 39 9-0F RTS 45 10-0B RTS 45 10-0F RTS 50 10-0B RTS 50 10-0F 20 20 25 25 25 30 30 30 35 35 35 39 39 39 45 45 50 50 5.9 x 3.1 x 20 6.5 x 3.7 x 20 5.9 x 2.4 x 25 7.0 x 3.5 x 25 7.0 x 3.5 x 25 6.6 x 2.4 x 30 8.0 x 3.8 x 30 8.0 x 3.8 x 30 7.3 x 2.4 x 35 8.5 x 3.6 x 35 9.5 x 4.6 x 35 7.8 x 2.4 x 39 9.0 x 3.6 x 39 9.0 x 3.6 x 39 10.0 x 3.7 x 45 10.0 x 3.7 x 45 10.0 x 3.0 x 50 10.0 x 3.0 x 50 0.125 0.125 0.125 0.125 0.188 0.125 0.125 0.188 0.125 0.125 0.125 0.125 0.125 0.188 0.125 0.188 0.125 0.188 Gauge 80 mph Max. wt. 90 mph Max. wt. 100 mph Max. wt. 11 11 11 11 7 11 11 7 11 11 11 11 11 7 11 7 11 7 19.3 24.2 12.5 20.3 28.5 11.7 18.9 27.5 11.2 18.9 23.2 10.7 17.2 28.5 17.4 28.5 13.2 20.5 482 605 312 507 760 292 473 838 280 472 580 267 430 715 435 715 330 512 15.1 19.3 9.9 16.2 24.0 9.3 14.9 27.0 8.9 15.1 18.2 8.5 13.5 23.0 13.5 23.0 10.6 16.5 377 482 247 405 625 232 373 675 222 377 455 212 338 575 338 575 265 412 12.2 15.6 8 13.1 19.8 7.5 12 22.0 7.1 12.2 14.5 6.6 10.8 19.0 10.6 19.0 8.3 13.6 305 390 200 327 495 187 300 550 177 305 363 165 270 475 265 475 208 340 Bolt Bolt Approx. Circle Size ship wt. (in.) in. x in. x in.) (lbs.) 9.0 9.5 9.0 10.0 10.0 9.5 11.0 11.0 10.5 11.5 13.0 11.0 12.5 12.5 13.5 13.5 13.5 13.5 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1-1/4 x 42 x 6 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1-1/4 x 42 x 6 1 x 36 x 4 1-1/4 x 42 x 6 1 x 36 x 4 1-1/4 x 42 x 6 140 160 155 200 280 200 265 380 250 315 370 285 355 515 450 650 475 680 Pole Data Shaft Base size NOTES: • Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) • Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° • Options: See page 202 • Brackets: See page 203-204 198 Product Guide 5.9" B 6.5" B 7.0" B 7.0" F 6.6" B 8.0" B 8.0" F 7.3" B 8.5" B 9.5" B 7.8" B 9.0" B 9.0" F 10.0" B 10.0" F Bolt Circle A 9" 9.5" 10" 10" 9.5" 11" 11" 10.5" 11.5" 13" 11" 12.5" 12.5" 13.5" 13.5" Bolt Projection B Base Square C Warehouse Bolt description 3-1/2"–4-1/4" 3-1/2"–4-1/4" 3-1/2"–4-1/4" 3-3/4"–4-1/2" 3-1/2"–4-1/4" 3-1/2"–4-1/4" 4-1/2–5-1/4" 3-1/2"–4-1/4" 3-3/4"–4-1/2" 3-3/4"–4-1/2" 3-3/4"–4-1/2" 3-3/4"–4-1/2" 4-1/2–5-1/4" 3-3/4"–4-1/2" 4-1/2–5-1/4" 10" 10-1/2" 10-7/8" 10-7/8" 10-1/2" 11-1/2" 11-1/2" 11-1/4" 12" 13" 11-1/2" 12-3/8" 12-3/8" 14" 14" AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 N/A AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 N/A AB36-0 N/A For more information please visit our website: www.americanelectriclighting.com Template Number PJ50075 PJ50074 PJ50077 PJ50076 PJ50078 PJ50079 PJ50080 PJ50081 PJ50082 PJ50083 PJ50084 PJ50085 PJ50086 PJ50087 PJ50088 SSS Anchor Base Poles Square Straight Steel P R O D U C T O V E R V I E W Intended Use For 10’ to 39’ mounting height. Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 3/4" or 1" diameter steel rod having a minimum-yield strength of 55,000 psi. Features Grounding – Nut holder located immediately inside handhole rim is provided with a 1/2" x13 UNC ground bolt and nut (by others). Shaft – Weldable grade, hot-rolled, commercial-quality carbon steel tubing with a minimum yield of 55,000 psi (11-gauge), 50,000 psi (7gauge). Uniform wall thickness of .125" or .188". Shaft is one-piece with a full-length, longitudinal, high frequency electric resistance weld. Uniformly square in cross-section with flat sides, small corner radii and excellent torsional qualities. Available shaft widths are 4, 5 and 6 inches. Handhole – 1/2”-13, Reinforced handhole rim having nominal dimensions of 3"x5" for all shafts. Includes steel cover with attachment screws. Anchor Base – Fabricated from hot-rolled carbon steel plate that meets or exceeds a minimum-yield strength of 36,000 psi. The anchor base is provided with slotted holes. Finish – Dark bronze polyester powder paint (DDB) standard; optional polyester powder paint finishes available. Hardware – Fasteners are high-strength, galvanized or zinc-plated or stainless steel. Top Cap – Removable top cap is provided for drill mount poles. Base Cover – Full-base cover finished to match pole. INSTALLATION NOTES: Ordering Information: See page 191 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust Nom. Pole Catalog mount. Shaft Size Number ht. (ft.) (in. x in. x ft.) SSS 10 4C SSS 12 4C SSS 14 4C SSS 16 4C SSS 18 4C SSS 20 4C SSS 20 4G SSS 20 5C SSS 20 5G SSS 25 4C SSS 25 4G SSS 25 5C SSS 25 5G SSS 30 4G SSS 30 5C SSS 30 5G SSS 30 6G SSS 35 5G SSS 35 6G SSS 39 6G 10 12 14 16 18 20 20 20 20 25 25 25 25 30 30 30 30 35 35 39 4.0 x 10.0 4.0 x 12.0 4.0 x 14.0 4.0 x 16.0 4.0 x 18.0 4.0 x 20.0 4.0 x 20.0 5.0 x 20.0 5.0 x 20.0 4.0 x 25.0 4.0 x 25.0 5.0 x 25.0 5.0 x 25.0 4.0 x 30.0 5.0 x 30.0 5.0 x 30.0 6.0 x 30.0 5.0 x 35.0 6.0 x 35.0 6.0 x 39.0 Wall Thick. 80 Max. 90 Max. 100 Max. (in.) Gauge mph wt. mph wt. mph wt. 0.125 0.125 0.125 0.125 0.125 0.125 0.188 0.125 0.188 0.125 0.188 0.125 0.188 0.188 0.125 0.188 0.188 0.188 0.188 0.188 11 11 11 11 11 11 7 11 7 11 7 11 7 7 11 7 7 7 7 7 30.6 24.4 19.9 15.9 12.6 9.6 14.0 17.7 28.1 4.8 10.8 9.8 18.5 6.0 4.7 10.7 19.0 5.9 12.4 7.2 765 610 498 398 315 240 350 443 703 150 270 245 463 150 150 267 475 150 310 180 23.8 18.8 15.1 11.8 9.2 6.7 11.0 12.7 21.4 2.6 7.7 6.3 13.3 4.0 2.0 6.7 13.2 2.5 7.6 3.0 595 470 378 295 230 167 275 343 535 100 188 157 333 100 50 167 330 100 190 75 18.9 14.8 11.7 8.9 6.7 4.5 8.0 9.4 16.2 1.0 5.4 3.7 9.5 2.5 — 3.9 9.0 — 4.2 — 473 370 293 223 168 150 200 235 405 50 135 150 238 75 — 100 225 — 105 — Bolt Bolt Approx. Circle Size ship wt. (in.) (in. x in. x in.) (lbs.) 8–9 8–9 8–9 8–9 8–9 8–9 8–9 10–12 10–12 8–9 8–9 10–12 10–12 8–9 10–12 10–12 11–13 10–12 11–13 11–13 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 18 x 3 3/4 x 30 x 3 1 x 36 x 4 1 x 36 x 4 3/4 x 18 x 3 3/4 x 30 x 3 1 x 36 x 4 1 x 36 x 4 3/4 x 30 x 3 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 75 90 100 115 125 140 198 185 265 170 245 225 320 295 265 380 520 440 540 605 Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately upon delivery to prevent finish damage. Pole Data Shaft Base size Bolt circle A Bolt projection B Base square C Warehouse Anchor Bolt description Template number 4"C 4"G 5" 6" 8-1/2" 8-1/2" 10"–12" 11"–13" 2-3/4"–4" 2-3/4"–4" 3-3/8"–4" 3-3/8"–4" 8" 8" 11" 12-1/2" AB18-0 AB30-0 AB36-0 AB36-0 PJ50004 PJ50004 PJ50010 PJ50011 NOTES: • Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. • (2" NPS) • Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° • Options: See page 202 • Brackets: See page 203-204 Product Guide 199 STS Anchor Base Poles Square Tapered Steel P R O D U C T O V E R V I E W Intended Use For 20’ to 50’ mounting height. Grounding – Nut holder located immediately inside handhole rim is tapped for a 1/2" – 13 UNC ground bolt and nut (by others). Features Handhole – Reinforced handhole rim having nominal dimensions of 3"x5" for shafts less than 6.375" square and 4"x6.5" for all other shafts. Steel cover with attachment screws included. Handhole is located 18" above base. Shaft – Weldable-grade (ASTM A595 Grade A) hot-rolled commercialquality carbon steel tubing with minimum yield of 55,000 psi. Uniform wall thickness of 11-gauge (0.1196") or 7-gauge (0.1793"). Shafts are constructed with full-length longitudinal high-frequency resistance weld and are square in cross-section, having flat sides, radiused corners and a uniform taper of approximately .11" per foot. Anchor Base – Fabricated from hot-rolled carbon steel plate that conforms with ASTM A36. Anchor Bolts – Fabricated from commercial-quality, hot-rolled carbon steel with minimum-yield strength of 55,000 psi. Bolts have an "L" bend on one end. Ordering Information: See page 191 (Note: Poles are available only in U.S.) Hardware – Fasteners are high-strength galvanized or zinc-plated or stainless steel. Top Cap – Removable top cap provided with all drill-mount poles. Finish – Must specify finish. Base Cover – Full-base cover finished to match pole. Technical Information EPA (ft2) with 1.3 gust Nom. Pole mount. Shaft Size ht. (ft.) (in. x in. x ft.) Catalog Number Wall Thick. (in.) Gauge 80 mph Max. wt. 90 mph Max. wt. 100 mph Max. wt. 0.125 0.188 0.125 0.188 0.125 0.188 0.125 0.188 0.125 0.188 0.188 0.188 0.188 18.0 30.5 16.8 28.5 13.6 23.6 10.7 23.4 8.6 19.3 16.0 23.5 19.4 452 764 422 713 340 590 269 585 215 483 400 588 485 13.8 24.0 12.6 22.5 9.8 17.9 7.3 17.4 5.4 14.2 11.1 16.6 13.2 345 602 315 563 245 448 184 435 135 355 278 415 332 10.7 19.0 9.5 18.2 7.0 13.7 4.8 13.0 3.0 10.4 7.4 11.4 8.7 268 477 238 455 175 343 120 325 75 260 187 287 218 Bolt Bolt Approx. Circle Size ship wt. (in.) (in. x in. x in.) (lbs.) INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factorysupplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately upon delivery to prevent finish damage. STS 20 5-2B STS 20 5-5F STS 25 6-0B STS 25 6-4F STS 30 6-4B STS 30 6-4F STS 35 6-8B STS 35 7-1F STS 39 7-1B STS 39 7-1F STS 45 7-8F STS 45 8-7F STS 50 8-8F 20 20 25 25 30 30 35 35 39 39 45 45 50 5.25 x 3.05 x 20 5.50 x 3.30 x 20 6.00 x 3.25 x 25 6.41 x 3.66 x 25 6.41 x 3.11 x 30 6.41 x 3.11 x 30 6.81 x 2.96 x 35 7.13 x 3.28 x 35 7.18 x 2.92 x 39 7.13 x 2.87 x 39 7.88 x 2.93 x 45 8.75 x 3.80 x 45 8.81 x 3.31 x 50 11 7 11 7 11 7 11 7 11 7 7 7 7 10-3/4 1 x 36 x 4 11 1 x 36 x 4 12 1 x 36 x 4 12-1/2 1 x 36 x 4 12-1/2 1 x 36 x 4 12-1/2 1 x 36 x 4 13 1 x 36 x 4 13-1/2 1 x 36 x 4 13-1/2 1 x 36 x 4 13-1/2 1 x 36 x 4 14-1/2 1 x 36 x 4 15-3/4 1-1/4 x 42 x 6 16 1-1/4 x42 x 6 NOTES: 1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) 2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° 3 Options: See page 202 4 Brackets: See page 203-204 Pole Data 200 Product Guide Shaft Base size Bolt Circle A Bolt Projection B Base Square C Warehouse Anchor Bolt description Template Number 5.2" B 5.5" F 6.0" B 6.4" F 6.4" B 6.8" B 7.1" F 7.1" B 7.8" F 8.7" F 8.8" F 10-3/4" 11" 12" 12-1/2" 12-1/2" 13" 13-1/2" 13-1/2" 14-1/2" 15-3/4" 16" 3-1/2–4-1/4" 3-3/4"–4-1/2" 3-1/2–4-1/4" 4"–4-3/4" 3-1/2–4-1/4" 3-1/2–4-1/4" 4-1/4"–5" 3-1/2–4-1/4" 4"–4-3/4" 4-3/4"–5-1/2" 4-1/2–5-1/4" 10-3/4" 11" 11-1/2" 11-7/8" 11-7/8" 12-1/4" 12-5/8" 12-5/8" 13-3/8" 14-1/4" 15-1/2" AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 AB42-0 AB42-0 PJ50095 PJ50096 PJ50097 PJ50098 PJ50099 PJ50101 PJ50102 PJ50103 PJ50105 PJ50106 PJ50107 For more information please visit our website: www.americanelectriclighting.com 155 235 205 310 260 375 305 475 345 500 620 730 780 STSH Anchor Base Poles Square Tapered Steel Hinge P R O D U C T O V E R V I E W Intended Use Anchor Bolts – Fabricated from commercial-quality, hot-rolled carbon steel with minimum-yield strength of 55,000 psi. Bolts have an "L" bend on one end. For 20’ to 39’ mounting height. Features Grounding – Nut holder located immediately inside handhole rim is tapped for a 1/2" – 13 UNC ground bolt and nut (provided by others). Shaft – Weldable-grade, hot-rolled, commercial-quality carbon steel having a guaranteed minimum yield strength of 55,000 psi and is supplied in 11-gauge (.1196") or 7-gauge (.1793") nominal thickness. Pole is one-piece construction with full-length, longitudinal, highfrequency, electric-resistance weld. Shaft is square in cross section having flat sides, radiused corners, and uniform taper of approximately 11” per foot (4-inch square poles are not tapered). Handhole – Reinforced handhole rim having nominal dimensions of 3" x 5" for shafts less than 6.375" square and 4" x 6.5" for all other shafts. Steel cover with attachment screws included. Handhole is located 18" above base on hinge side. Hardware – Fasteners are high-strength, galvanized or zinc-plated or stainless steel. Hinge – The hinge includes a stainless steel hinge pin. A flexible wiring guide is provided, passing through the hinge area for wiring protection. Hinge is external. Top Cap – Removable top cap provided with all drill-mount poles. Finish – Dark bronze polyester powder finish (DDB) standard; other architectural colors available. Anchor Base – Fabricated from hot-rolled carbon steel plate that conforms with ASTM A36. Base Cover – Full-base cover is provided. Ordering Information: See page 191 (Note: Poles are available only in U.S.) INSTALLATION NOTES: Technical Information EPA (ft ) with 1.3 gust 2 Catalog Number Nom. Pole Wall mount. Shaft Size Thick. 80 Max. ht. (ft.) (in. x in. x ft.) (in.) Gauge mph wt. STSH 20 4F STSH 25 4B STSH 25 6-4B STSH 30 4F STSH 30 6-4B STSH 35 7-1B STSH 35 7-1F STSH 39 7-1F 20 25 25 30 30 35 35 39 4 x 4 x 20 4 x 4 x 25 6.41 x 3.63 x 25 4 x 4 x 30 6.41 x 3.08 x 30 7.18 x 2.88 x 35 7.13 x 2.87 x 35 7.13 x 2.87 x 39 0.188 0.188 0.125 0.188 0.125 0.125 0.188 0.188 7 7 11 7 11 11 7 7 11.6 7.1 18.0 4.0 12.5 7.1 22.0 19.5 217 160 254 120 230 160 155 110 90 Max. mph wt. 100 mph Max. wt. 8.5 4.8 13.0 2.1 8.3 3.2 16.9 13.5 6.2 3.1 9.3 0.8 5.1 — 12.1 9.2 217 160 254 120 230 — 155 110 217 160 254 120 230 160 155 110 Bolt Bolt Approx. Circle Size ship wt (in.) (in. x in. x in.) (lbs) 8-1/2-10 3/4 x 18 x 3 8-1/2-10 3/4 x 18 x 3 12-1/2 1 x 36 x 4 8-1/2-10 3/4 x 18 x 3 12-1/2 1 x 36 x 4 13-1/2 1 x 36 x 4 13-1/2 1 x 36 x 4 13-1/2 1 x 36 x 4 300 370 355 435 440 540 700 740 Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately upon delivery to prevent finish damage. External Hinge Detail NOTES: • Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) • Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° • Options: See page 202 • Brackets: See page 203-204 Pole Data Shaft Base size 4.0" F 6.4" B 7.1" F 7.1" B Bolt Circle A Bolt Projection B 8-1/2–10" 3-1/2–4-1/4" 12-1/2" 3-3/4"–4-1/2" 13-1/2" 4"–4-3/4" 13-1/2" 3-1/2–4-1/4" Base Square C Warehouse Anchor Bolt description Template Number 9-3/4" 11-7/8" 12-5/8" 12-5/8" AB18-0 AB36-0 AB36-0 AB36-0 PJ50091 PJ50092 PJ50093 PJ50094 Winch Detail (accessory) Winch Ordering Family Winch Shaft size Order nomenclature STSH WCH 4F or 4B 6-4B 7-1B 7-1F STSHWCH 4F STSHWCH 6-4B STSHWCH 7-1B STSHWCH 7-1F Product Guide 201 Pole Options P R O D U C T O V E R V I E W Anchor Bolts Horizontal Arm Bracket Available in various sizes for use with American Electric Lighting poles. Set includes hex nuts and washers. Anchor bolt is partially galvanized for exposed threads per ASTM-A153. Bolts have minimum-yield strength rating of 55,000 psi, AASHTO M314 GR55. See individual pole catalog pages for anchor bolt sizes and description. Single or twin side-mounted horizontal arm brackets for additional luminaires. Made from 2 3/8," pipe. Upright is 18" from pole; special arm lengths may be available upon request. Arms are rated for luminaires up to 4.5 sq. ft. EPA and 100 lbs. per arm. When ordering, specify location in height and feet above base of pole and orientation from the handhole. Base Covers Option Two-piece, full-base cover. Four fasteners provided to secure pieces together. Finished to match pole. Shipped separately. Standard with steel poles only. H1-18A Aluminum H1-18S Steel HI-18F Fiberglass HI-18C Concrete Option Pole (square) Dimension (depth) Dimension SBC4 SBC5 SBC6 SSS 4" SSS 5" SSS 6" 8.75" 11.44" 13.5" x 5.8" x 6.4" x 4" Festoon Outlets Provision provided for mounting duplex outlet. When ordering, specify location in height and feet above base of pole and orientation from the handhole. Description FDL Festoon Duplex Outlet, Less Electric Handheld Cover Plates Note: SSS and SSA arm attachment is slightly different from RTA. Arm modifications located on pole to accept arms. Arms shipped as separate item. It has been found that steady 10-30 mph winds sometimes induce second or higher mode of vibration in lighting poles. Second mode vibration is characterized by the maximum periodic motion occurring at approximately the mid-height of the pole. This type of vibration can result in failure of the pole and/or luminaire. There is no method of predicting destructive light pole vibration. Vibration dampers which alleviate this condition are available. Shipped installed. Four nut covers are standard for RSA, RTA and RTS poles only. All other poles order as handhole cover for full pole description. Also specify if pole is existing. Tenon Dimensions. Bolt-on Tenon Square Steel Poles Tenon Mounting Slipfitters (Order separately) Number of fixtures Tenon O.D. One Two@180° 2-3/8" 2-7/8" 4" T20-190 T25-190 T35-190 T20-280 T25-280 T35-280 Two@90° Three@120° Three@90° Four@90° T20-290 T25-290 T35-290 T20-320 T25-320 T35-320 T20-390 T25-390 T35-390 T20-490 T25-490 T35-490 Threaded couplings and/or nipples can be factory installed. When ordering, specify location in height and side of pole (ex: A, B, C, D). threaded coupling threaded coupling threaded coupling Product Guide NPL12 NPL34 NPL1 1/2" 3/4" 1" threaded nipple threaded nipple threaded nipple" Cat. No. A B C D Wt. (lbs.) SBT-4S1 SBT-5S1 SBT-6S2 2-3/8" 2-3/8" 2-3/8" 3" 4" 5" 13-3/4" 13-3/4" 13-3/4" 5" 5" 5" 7 8 17 Notes: 1 2 Couplings & Nipples 202 7 11 8 9 Nut Covers SSS HHC: For all SSS poles 1/2" 3/4" 1" .43 .50 .45 .55 Note: FVD - Field installable vibrator damper available upon request. Consult factory. SSS CPL12 CPL34 CPL1 Weight (lbs.) VD - Vibration Damper For full-base cover on other poles, must order FBC. When ordering separately, specify full pole nomenclature; i.e., FBC for RTA 25 7E. Also specify if pole is existing. Option EPA (sq. ft.) Stocked in distribution centers. Ordered on a drop-ship basis. Tamperproof Screws Tamperproof (TP): Order as TP. Tamperproof screws provided with base cover. For more information please visit our website: www.americanelectriclighting.com Handhole Opening Field Installed Vibration Dampener Foundation Aluminum Mounting Brackets Bullhorns and Spokes - order as separate items P R O D U C T Projected area is for bracket only. Bracket projected area is added to luminaire projected area to get total effective projected area (EPA). All brackets have a maximum luminaire rating per tenon of 4.5 sq. ft. projected area and 100 lbs. at a wind velocity of 100 mph (luminaire drag coefficient = 1.0). O V E R V I E W Brackets for Aluminum Poles Only RBA32 RBA28 Finish Natural aluminum. Optional painted finishes available. Plastic cap supplied. RBA48 Round Pole Brackets mount to T25 tenon 2-7/8” O.D., or pole top that is 2-7/8” O.D. Heavy duty version mounts to T35 tenon 4” O.D. Catalog Number EPA (sq. ft.) Weight (lbs.) Catalog Number EPA (sq. ft.) Weight (lbs.) RBA28 RBA32 RBA38 RBA48 RBA49 1.2 1.7 1.9 2.7 2.2 7.0 14.3 10.5 14.5 17.5 RBA28 HD RBA32 HD RBA38 HD RBA48 HD RBA49 HD 1.3 1.7 2.0 2.8 2.2 8.4 12.7 11.9 16.2 15.8 Square Pole RBA38 RBA49 Brackets for Aluminum Poles Only Brackets flush mount on 4", 5" and 6" square poles. For use with internal sleeve, plain open-top poles, American Electric Lighting poles only. Must be ordered with pole to ensure proper fit. Catalog Number EPA (sq. ft.) Weight (lbs.) SBA28 SBA38 SBA48 SBA49 0.90 1.50 2.25 1.7 12 17 22 22 SBA38 SBA49 6" SBA48 SBA28 Product Guide 203 Steel Mounting Brackets Bullhorns and Spokes - order as separate items P R O D U C T O V E R V I E W Projected area is for bracket only. Bracket projected area is added to luminaire projected area to get total effective projected area (EPA). All brackets have a maximum luminaire rating per tenon of 4.5 sq. ft. projected area and 100 lbs. at a wind velocity of 100 mph (luminaire drag coefficient = 1.0). Brackets for Steel Poles Only BS28 Finish Dark bronze, standard. Other colors available (consult local American Electric Lighting representative). Plastic cap supplied. Standard Hub Catalog Number EPA (sq. ft.) Weight (lbs.) BS28 BS32 BS38 BS48 BS49 1.0 1.3 1.6 2.3 1.6 21.0 34.0 32.0 44.0 44.0 O.D. 2 7/8” - I.D. 2 1/2” Requires T20 Tenon (min. 5” tall) Heavy Duty Hub O.D. 4 1/2” - I.D. 4” Requires T35 Tenon (min. 6” tall) BS32 BS38 204 Catalog Number EPA (sq. ft.) Weight (lbs.) BS28 HD BS32 HD BS38 HD BS48 HD BS49 HD 1.3 2.0 2.2 3.4 2.8 28.0 38.0 38.0 47.0 46.0 BS48 BS49 Finish Brackets for Square Steel Poles Only Dark bronze, standard. Requires T20 (2-3/8" max OD) tenon on pole for mounting Catalog Number EPA (sq. ft.) Weight (lbs.) SBS 28 SBS 38 SBS 49 1.1 1.7 2.1 30.0 42.0 45.0 Product Guide SBS28 SBS38 For more information please visit our website: www.americanelectriclighting.com SBS49 RTF Anchor Base Poles Round Tapered Fiberglass P R O D U C T O V E R V I E W Intended Use For 20’ to 45’ mounting height. Hardware – Fasteners are high-strength galvanized or zinc-plated or stainless steel. Construction Top Cap – Removable top cap provided with all drill-mount poles. Shaft – “E” type fiberglass reinforced composite shaft incorporating pigmented, UV inhibiting, thermosetting polyester resin and a smooth surface finished with a polyurethane surface coat providing a minimum 1.5 mil dry film thickness. Finish – Ultraviolet resistant and pigmented approximately the same color as the final polyurethane coating. Must specify color. Base Cover – Full base cover is optional and finished to match pole. Anchor Base – Heavy-duty, A356-T6 aluminum base casting is permanently bonded to the outside of the fiberglass shaft. Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 1” or 1-1/4” diameter steel rod having a minimum-yield strength of 55,000 psi. Handhole – An oval, non-metallic, 2 1/2"x5" handhole secured with a vandal resistant fastener. Ordering Information: See page 191 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust Catalog Number INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately upon delivery to prevent finish damage. RTF 20 7-3X RTF 25 7-3X RTF 30 8-4X RTF 30 8-5X RTF 30 10-5X RTF 35 8-4X RTF 35 8-5X RTF 35 11-2X RTF 40 11-7X RTF 40 11-8X RTF 40 12X RTF 45 11-7X RTF 45 11-9X Nom. Pole mount. Shaft Size ht. (ft.) (in. x in. x ft.) 20 25 30 30 30 35 35 35 40 40 40 45 45 7.3 x 4.6 x 20 7.3 x 4.6 x 25 8.4 x 4.6 x 30 8.5 x 4.8 x 30 10.5 x 6.6 x 30 8.4 x 4.6 x 35 8.5 x 4.8 x 35 11.2 x 6.6 x 35 11.7 x 6.2 x 40 11.8 x 6.4 x 40 12.0 x 6.9 x 40 11.7 x 6.2 x 45 11.9 x 6.6 x 45 80 mph 90 mph 100 mph Max. wt. Bolt Circle (in.) Bolt Approx. Size ship wt. (in. x in. x in.) (lbs.) 14.4 9.6 11.2 15.6 28.7 5.5 8.5 21.8 6.4 12.2 25.8 3.9 15.2 11.1 7.3 8.5 12.0 22.4 3.8 6.2 16.6 4.3 8.8 19.3 2.0 10.9 8.9 5.7 6.7 9.5 17.4 2.7 4.7 12.5 2.4 6.0 14.3 0.6 7.6 200 200 100 200 300 100 200 300 165 300 300 300 300 11-1/2 11-1/2 11-1/2 11-1/2 14-1/2 11-1/2 11-1/2 15 15-1/2 15-1/2 15-1/2 15-1/2 15-1/2 1 x 30 x 4 1 x 30 x 4 1 x 30 x 4 1 x 30 x 4 1 x 30 x 4 1 x 30 x 4 1 x 30 x 4 1-1/4 x 36 x 6 1-1/4 x 36 x 6 1-1/4 x 36 x 6 1-1/4 x 36 x 6 1-1/4 x 36 x 6 1-1/4 x 36 x 6 62 75 106 140 202 125 161 248 165 227 317 183 295 Pole Data 4” Bolt Projection Shaft Base size Bolt Circle A Bolt Projection B Base Square C Template Number 7.3" 8.4" 8.5" 10.5" 11.2 11.7" 11.8" 11.9" 12.0" 11.5" 11.5" 11.5" 14.5" 15" 15.5" 15.5" 15.5" 15.5" 4" 4" 4" 4" 4" 4" 4" 4" 4" 11" 11" 11" 13.3" 13.5" 14" 14" 14" 14" PJ50114 PJ50115 PJ50116 PJ50117 PJ50118 PJ50119 PJ50120 PJ50121 PJ50122 NOTES: 1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) 2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° 3 Options: See page 202 4 Brackets: See page 203-204 Product Guide 205 RTFDB Direct Buried Poles Round Tapered Fiberglass P R O D U C T O V E R V I E W Intended Use Hardware – Fasteners are high-strength galvanized or zinc-plated or stainless steel. For direct burial, 14’ to 35’ mounting height. Top Cap – Removable top cap provided with all drill-mount poles. Finish – Ultraviolet resistant and pigmented approximately the same color as the final polyurethane coating. Must specify color. Construction Shaft – “E” type fiberglass reinforced composite shaft incorporating pigmented, UV inhibiting, thermosetting polyester resin and a smooth surface finished with a polyurethane surface coat providing a minimum 1.5 mil dry film thickness. Handhole – An oval, non-metallic, 2 1/2"x5" handhole secured with a vandal-resistant fastener. Ordering Information: See page 191 (Note: Poles are available only in U.S.) INSTALLATION NOTES: Technical Information Do not erect poles without having fixtures installed. EPA (ft2) with 1.3 gust Catalog Number RTFDB 18 6X RTFDB 20 6-6X RTFDB 24 6-7X RTFDB 30 8-3X RTFDB 30 8-4X RTFDB 35 8-4X RTFDB 35 8-5X RTFDB 41 11-8X Nom. mount. ht. (ft.) Pole Shaft Size (in. x in. x ft.) 80 mph 90 mph 100 mph 14 16 20 25 25 30 30 35 6.0 x 4.1 x 18 6.6 x 4.1 x 20 6.7 x 4.1 x 24 8.3 x 4.4 x 30 8.4 x 4.6 x 30 8.4 x 4.6 x 35 8.5 x 4.9 x 35 11.8 x 6.4 x 41 14.0 10.0 8.2 6.2 14.5 10.5 14.8 14.3 10.4 7.4 5.8 4.7 11.2 8.0 11.4 10.8 7.9 5.5 4.1 3.6 8.9 6.2 9.0 7.8 Approx. Max. ship wt. wt. (lbs.) 150 100 150 100 200 200 300 300 If poles are stored outside, all protective wrapping must be removed immediately upon delivery to prevent finish damage. 34 38 46 71 98 116 153 218 NOTES: 1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) 2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° 3 Options: See page 202 4 Brackets: See page 203-204 206 Product Guide For more information please visit our website: www.americanelectriclighting.com SSF Anchor Base Poles Square Straight Fiberglass P R O D U C T O V E R V I E W Intended Use For 6’ to 30’ mounting height. Features Hardware – Fasteners are high-strength galvanized or zinc-plated or stainless steel. Shaft – Constructed by the pultrusion process from thermosetting polyester resin and contains a minimum of 65 percent "E" type fiberglass by weight. The fiberglass strands traverse the length of the pole. Top Cap – Removable top cap provided with all drill-mount poles. Anchor Base – Heavy-duty, A356-T6 aluminum base casting is permanently bonded to the outside of the fiberglass shaft. Finish – Ultraviolet resistant and pigmented approximately the same color as the final polyurethane coating. Dark bronze (DDB) is standard. Must specify color. Base Cover – Full base cover is optional and finished to match pole. Anchor Bolts – Top 12" galvanized per ASTM A-153. Made of 5/8" or 1" diameter steel rod having a minimum-yield strength of 55,000 psi. Handhole – An oval, non-metallic, 2 1/2" x 5" handhole secured with a vandal-resistant, stainless steel 1/4" socket head screw. INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately upon delivery to prevent finish damage. SSF 4” Shaft Ordering Information: See page 191 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust Catalog Number SSF 6 4X SSF 8 4X SSF 10 4X SSF 12 4X SSF 14 4X SSF 16 4X SSF 20 4X SSF 20 5X SSF 25 4X SSF 25 5X SSF 30 5X SSF 30 5XHD Nom. Pole mount. Shaft Size 80 ht. (ft.) (in. x in. x ft.) mph 6 8 10 12 14 16 20 20 25 25 30 30 4x4x6 4x4x8 4 x 4 x 10 4 x 4 x 12 4 x 4 x 14 4 x 4 x 16 4 x 4 x 20 5 x 5 x 20 4 x 4 x 25 5 x 5 x 25 5 x 5 x 30 5 x 5 x 30 23.2 16.5 12.0 9.1 6.7 3.7 7.2 12.2 4.2 8.7 4.7 8.6 90 mph 100 mph Max. wt. 17.9 12.6 8.9 6.5 4.4 2.2 1.8 9.1 2.5 6.2 2.8 5.1 14.2 9.8 6.7 4.6 2.8 1.1 0.5 6.9 0.75 4.4 1.9 2.6 150 150 150 100 100 100 150 200 150 200 200 200 Bolt Bolt Approx. Circle Size ship wt. (in.) (in. x in. x in.) (lbs.) 8 8 8 8 8 8 8 11 8 11 11 10-12 5/8 x 21 x 3 5/8 x 21 x 3 5/8 x 21 x 3 5/8 x 21 x 3 5/8 x 21 x 3 5/8 x 21 x 3 5/8 x 21 x 3 1 x 30 x 4 5/8 x 21 x 3 1 x 30 x 4 1 x 30 x 4 1 x 30 x 4 18 23 27 31 35 39 80 110 90 115 120 164 Pole Data SSF 5” Shaft Shaft Base size Bolt Circle A Bolt Projection B Base Square C Anchor Bolt description Template Number 4" 5" 8" 11" 3" 4" 7.4" 11.1" ABSSF-4 ABSSF-5 PJ50123 PJ50124 NOTES: 1 Mounting Arrangement: (PT) Open Top; (T20) 2-3/8" O.D. (2" NPS) 2 Drill Mounting: (DM19) 1 fixture at 90°; (DM28) 2 fixtures at 180° 3 Options: See page 202 4 Brackets: See page 203-204 Product Guide 207 STC Direct Burial Poles Square Tapered Concrete P R O D U C T O V E R V I E W Intended Use Handhole – A 3"x5" handhole is located 18" above ground line and a 2 1/2" x 7" minimum conduit entrance is located 18" below ground line. Inserts for the handhole and conduit entrance are non-corrosive and weatherproof. Handhole frames and covers conform to ASTM-B240. For direct burial, 16’ to 38’ mounting height. Features Shaft – Concrete mix has a minimum 28-day compressive strength of 8,500 PSI and conforms with ASTM-C150. Prestressing steel reinforcement is uncoated 7 wire, stress relieved strand per ASTMA416. Steel spiral reinforcement conforms to ASTM-A82 and is not less than .120 (11-gauge) diameter. Poles have a continuous taper of 0.165 inches per foot. Grounding – An 18" long, #4 stranded copper pigtail, connected to reinforced strand, is provided at pole top and at cable entrance below grade. Hardware – Fasteners are high-strength galvanized or stainless steel. Finish – Smooth, natural form finish, soft gray color is standard. Ordering Information: See page 191 (Note: Poles are available only in U.S.) INSTALLATION NOTES: Technical Information Do not erect poles without having fixtures installed. EPA (ft2) with 1.3 gust Catalog Number STC 13-4X STC 20 7-24X STC 20 9-24X STC 24 4-80X STC 24 5-60X STC 24 6-40X STC 25 8-05X STC 25 10-05X STC 30 8-86X STC 30 10-86X STC 35 9-67X STC 35 11-67X STC 35 6-40X STC 35 7-25X STC 36-8X STC 40 12-48X STC 45 13-29X STC 46-8X STC 47 9-25X 208 Nom. mount. ht. (ft.) Pole Shaft Size (in. x in. x ft.) 80 mph Max wt. 90 mph Max wt. 100 mph Max. wt. Approx. ship wt. (lbs.) 10 16 16 20 20 20 20 20 25 25 29 29 30 30 30 34 38 40 40 4.0 x 4.0 x 13 4.0 x 7.24 x 20 6.0 x 9.24 x 20 4.8 x 4.8 x 24 5.6 x 5.6 x 24 6.4 x 6.4 x 24 4.0 x 8.05 x 25 6.0 x 10.05 x 25 4.0 x 8.86 x 30 6.0 x 10.86 x 30 4.0 x 9.67 x 35 6.0 x 11.67 x 35 6.4 x 6.4 x 35 7.25 x 7.25 x 35 8.0 x 8.00 x 36 6.0 x 12.48 x 40 6.0 x 13.29 x 45 8.0 x 8.0 x 46 9.25 x 9.25 x 47 3.5 22 48 3.5 3.5 3.5 21 44 20 49 17 43 3.5 3.5 3.2 42 41 3.5 3.5 100 550 1,220 510 510 510 510 1,050 460 1,090 400 1,010 400 1,010 920 820 820 820 820 3.5 16 37 N/A 3.5 3.5 16 34 15 33 12 32 N/A 3.5 3.5 30 31 N/A 3.5 430 430 950 N/A 390 390 390 810 340 830 290 760 N/A 760 670 590 590 N/A 000 3.5 13 29 N/A N/A 3.5 12 26 11 28 8 24 N/A N/A 3.5 22 21 N/A N/A 330 330 760 N/A N/A 300 300 640 250 650 200 580 N/A N/A 500 420 420 N/A N/A 189 680 1,110 517 686 917 985 1,530 1,350 2,000 1,800 2,540 1,337 1,685 2,145 3,130 3,795 2,740 3,813 Product Guide If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. For more information please visit our website: www.americanelectriclighting.com SPRTC Direct Burial Poles Round Tapered Concrete Sportslighting P R O D U C T O V E R V I E W Intended Use For 45’ to 115’ mounting height. Features Shaft – Concrete mix has a minimum 28-day compressive strength of 11,000 PSI and conforms with ASTM-C150. Prestressing steel reinforcement is uncoated 7 wire, stress relieved strand per ASTMA416. Steel spiral reinforcement conforms to ASTM-A82 and is not less than .203 (5-gauge wire) diameter. Poles have a continuous taper of 0.216 inches per foot. Poles are centrifugally spun and round in cross-section with a hollow center. Handhole – 4"x8" handhole is located 24" above ground line. 4"x8" conduit entrance is located 18" below ground line. 2 1/2"x8" reinforced handhole with flush cover is located at cage/crossarm locations. 11/2" coupling wire inlet/outlet is located opposite this handhole. Inserts for handhole and conduit entrance are non-corrosive and weatherproof. Handhole frames and covers conform to ASTM-B240. Grounding – A continuous solid or stranded copper ground wire is cast into the pole. Wire terminates at top of pole to accept a 1/2"x24" lightning rod. Copper coupling, approximately 12” below grade, provides a 1/2" tapped insert at pole face for grounding hardware. Hardware – Fasteners are high-strength galvanized or stainless steel. Finish – Smooth, natural form finish, soft gray color is standard. Ordering Information: See page 191 (Note: Poles are available only in U.S.) INSTALLATION NOTES: Technical Information Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. EPA (ft2) with 1.3 gust Catalog Number SPRTC C6 45 7-17 SPRTC C5 45 7-17 SPRTC C4 45 7-17 SPRTC C4 60 7-20 SPRTC C2 60 9-22 SPRTC H1 60 9-22 SPRTC C3 70 9-24 SPRTC C1 70 9-24 SPRTC H2 70 10-24 SPRTC C2 80 9-26 SPRTC C1 80 9-26 SPRTC H2 80 10-26 SPRTC C2 90 9-28 SPRTC C1 90 9-28 SPRTC H2 90 10-28 SPRTC C1 105 9-32 SPRTC H1 105 9-32 SPRTC H3 105 11-34 SPRTC C1 115 9-34 SPRTC H1 115 9-34 SPRTC H2 115 10-34 Nom. mount. ht. (ft.) Pole Shaft Size (in. x in. x ft.) 80 mph Max wt. 90 mph Max wt. 100 mph 38 38 38 50 50 50 60 60 60 68 68 68 77 77 77 91 91 91 100 100 100 6.75 X 16.47 X 45 6.75 X 16.47 X 45 6.75 X 16.47 X 45 6.75 X 19.71 X 60 8.82 X 21.78 X 60 8.82 X 21.78 X 60 8.82 X 23.94 X 70 8.82 X 23.94 X 70 8.82 X 23.94 X 70 8.82 X 26.1 X 80 8.82 X 26.1 X 80 8.82 X 26.1 X 80 8.82 X 28.26 X 90 8.82 X 28.26 X 90 8.82 X 28.26 X 90 8.82 X 31.5 X 105 8.82 X 31.5 X 105 11.0 X 33.68 X 105 8.82 X 33.66 X 115 8.82 X 33.66 X 115 8.82 X 33.66 X 115 31 39 52 47 85 138 56 90 139 63 85 136 54 78 132 70 99 144 65 96 125 620 780 1,040 893 1,615 2,622 1,064 1,710 2,641 1,197 1,445 2,584 1,026 1,482 2,508 1,330 1,881 2,736 1,235 1,824 2,375 24 30 40 35 65 101 42 69 103 45 65 101 39 56 97 49 74 105 45 70 91 480 600 800 665 1,235 1,919 798 1,311 1,957 855 1,105 1,919 741 1,064 1,843 931 1,406 1,995 855 1,330 1,729 18 23 31 26 48 80 32 52 81 34 48 79 28 42 75 35 54 80 31 50 69 Approx. Max. Ship wt. wt. (lbs.) 360 460 589 520 912 1,520 608 988 1,539 646 816 1,501 532 798 1,425 665 1,026 1,520 589 950 1,311 3,400 3,400 3,450 5,450 7,950 8,100 9,900 10,100 10,400 12,300 12,300 12,800 14,850 14,950 15,350 19,250 19,450 22,050 22,350 22,550 22,800 Product Guide 209 SPRTC Crossarm Options For Round Tapered Concrete and Wood Sportslighting Poles P R O D U C T O V E R V I E W Angle Iron Crossarms for Concrete Poles Projected area is for the crossarm only. The crossarm projected area is added to the luminaire projected area to get a total effective projected area (EPA). ACRCW4 4-Fixture Angle Arm ACRCW3 3-Fixture Angle Arm 6'- 0" 1'- 9" ACRCW2 2-Fixture Angle Arm Notes: 1 Connecting hardware for crossarm to pole is supplied by others. Bolt holes in c-channel are 0.88” diameter. 210 Product Guide For more information please visit our website: www.americanelectriclighting.com SPRTC Crossarm Options For Round Tapered Concrete and Wood Sportslighting Poles P R O D U C T O V E R V I E W Angle Iron Crossarms for Concrete or Wood Poles Projected area is for the crossarm only. The crossarm projected area is added to the luminaire projected area to get a total effective projected area (EPA). ACRCW6 6-Fixture Angle Arm ACRCW5 5-Fixture Angle Arm Angle Iron Crossarms For Concrete Poles Catalog Number Arm EPA (sq. ft.) Weight (lbs.) ACRCW2 ACRCW3 ACRCW4 ACRCW5 ACRCW6 1.80 3.00 4.50 5.70 7.00 50.0 86.0 121.0 157.0 193.0 Notes: 1 Connecting hardware for crossarm to pole is supplied by others. Bolt holes in c-channel are 0.88” diameter. Product Guide 211 SPRTC Crossarm Options For Round Tapered Concrete and Wood Sportslighting Poles P R O D U C T O V E R V I E W Pre-wired Tubular Crossarms for Concrete or Wood Poles Pre-wired Tubular Crossarms For Concrete Poles Projected area is for the crossarm only. The crossarm projected area is added to the luminaire projected area to get a total effective projected area (EPA). SPXCW6 Catalog Number EPA (sq. ft.) Weight (lbs.) SPXCW2 SPXCW3 SPXCW4 SPXCW5 SPXCW6 1.00 1.80 2.50 3.20 3.90 23.5 40.0 56.5 73.0 89.5 6-Fixture Crossarm SPXCW5 5-Fixture Crossarm SPXCW4 SPXCW2 4-Fixture Crossarm 2-Fixture Crossarm 6.50” SPXCW3 3-Fixture Crossarm Notes: 1 Connecting hardware for crossarm to pole is supplied by others. Bolt holes in c-channel are 0.88” diameter. 212 Product Guide For more information please visit our website: www.americanelectriclighting.com SPRTS Anchored Base Poles Round Tapered Steel P R O D U C T Intended Use O V E R V I E W For 40’ to 80’ mounting height. Handhole – An oval, reinforced handhole rim having a nominal dimension of 4"x6.5". Steel cover with attachment screws included. Handhole is located 18" above base. Features Grounding – Nut holder located immediately inside handhole rim is provided with 1/2" – 13 UNC ground bolt and nut. Shaft – The cross section shall be round or 16-sided with a 4" bend radius. Each pole is a constant tapered hollow steel section and shall be up to 55 feet in length with a minimum 1 1/2 times diameter slip joint as standard. The pole shaft sections shall be high strength low alloy steel conforming to ASTM A572 Grade 65 or ASTM A595 Grade A. The plate shall be single thickness – no laminations. Anchor Bolts – Fabricated from commercial-quality hot-rolled carbon steel with minimum-yield strength of 55,000 PSI. Bolts have an "L" bend on one end. Hardware – Fasteners are high-strength galvanized or zinc-plated or stainless steel. Top Cap – Weather-proof removable top cap provided with all drillmount poles. Anchor Base – Fabricated from hot-rolled carbon steel plate that conforms to ASTM A36 or ASTM A572 Grade 42. Ordering Information: See page 191 (Note: Poles are available only in U.S.) Technical Information EPA (ft2) with 1.3 gust Catalog Number SPRTS 40 HT01 SPRTS 40 HT02 SPRTS 40 HT03 SPRTS 50 HT01 SPRTS 50 HT02 SPRTS 50 HT03 SPRTS 50 HT04 SPRTS 50 HT05 SPRTS 60 HT01 SPRTS 60 HT02 SPRTS 60 HT03 SPRTS 60 HT04 SPRTS 70 HT01 SPRTS 70 HT02 SPRTS 70 HT03 SPRTS 70 HT04 SPRTS 70 HT05 SPRTS 80 HT01 SPRTS 80 HT02 SPRTS 80 HT03 SPRTS 80 HT04 Nom. Base mount. Dia. ht (ft.) (in.) 40 40 40 50 50 50 50 50 60 60 60 60 70 70 70 70 70 80 80 80 80 — — — — — — — — 5 6.5 6.6 12 6.6 6.6 12 12 12 12 12 13 12 Wall Thick. (in.) Base Dia. (in.) Wall Thick. (in.) 80 mph Max. wt. 90 mph Max. wt. 100 mph Max. wt. Bolt Bolt Num. of Circle Size Anchor (in.) (in. x in. x in.) Bolts — — — — — — — — 0.1196 0.1196 0.1793 0.1793 0.1793 0.1793 0.1793 0.1793 0.1793 0.1793 0.1793 0.1875 0.1793 9 9 10 10 10 11 13 13 11.5 13 13 15.87 13 13 14.57 15.87 16.82 15.87 16.82 17.53 18.7 0.1193 0.1793 0.1793 0.1193 0.1793 0.1793 0.1793 0.2391 0.1793 0.1793 0.2391 0.1875 0.1793 0.2391 0.1875 0.1875 0.1875 0.1875 0.1875 0.2092 0.1875 17.2 26.1 38.6 13.2 20.5 29.9 50.4 69.2 20.0 36.0 49.0 78.0 20.6 23.8 39.0 52.0 65.0 37.0 45.0 58.0 70.0 430 654 965 330 512 748 1,260 1,730 600 1,080 1,470 2,340 515 595 1,170 1,560 1,950 1,110 1,350 1,740 2,100 13.5 20.6 30.6 10.6 16.5 23.5 39.7 55.0 16.0 29.0 40.0 62.0 16.7 19.3 30.0 41.0 53.0 29.0 36.0 46.0 56.0 338 517 765 265 412 588 992 1,375 480 870 1,200 1,860 417 482 900 1,230 1,590 870 1,080 1,380 1,680 10.8 16.7 24.6 8.3 13.6 18.6 31.4 44.2 13.0 22.0 32.0 50.0 13.7 15.9 23.0 33.0 42.0 23.0 28.0 35.0 44.0 270 419 615 208 340 465 785 1,105 390 660 960 1,500 342 397 690 990 1,260 690 840 1,050 1,320 12.5 12.5 13.5 13.5 13.5 15 17 17.5 16 17 17 21 17 17.5 19 21 22.75 21 22.75 23 23 1 x 36 x 4 1.25 x 42 x 6 1.25 x 42 x 6 1 x 36 x 4 1.25 x 42 x 6 1.25 x 42 x 6 1.50 x 54 x 6 1.75 x 84 x 6 1.25 x 42 x 6 1.25 x 42 x 6 1.50 x 54 x 6 1.50 x 54 x 6 1.50 x 54 x 6 1.75 x 84 x 6 1.25 x 42 x 6 1.50 x 54 x 6 1.50 x 54 x 6 1.50 x 54 x 6 1.50 x 54 x 6 1.50 x 54 x 6 1.50 x 54 x 6 4 4 4 4 4 4 4 4 4 6 6 6 4 4 6 6 6 6 6 6 8 INSTALLATION NOTES: Installation requires grout to be packed under base to ensure full contact with foundation. Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use American Electric Lighting factory templates. Do not erect poles without having fixtures installed. If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. 4-Bolt 6-Bolt 8-Bolt Handhole Handhole Handhole Product Guide 213 SPRTS Crossarm Options For Round Tapered Steel Sportslighting Poles P R O D U C T O V E R V I E W Angle Iron Crossarms for Steel Poles Pre-wired Tubular Crossarms For Steel Poles Projected area is for the crossarm only. The crossarm projected area is added to the luminaire projected area to get a total effective projected area (EPA). ACR6 6-Fixture Angle Arm 214 ACR5 ACR4 5-Fixture Angle Arm 4-Fixture Angle Arm ACR3 ACR2 3-Fixture Angle Arm 2-Fixture Angle Arm Product Guide For more information please visit our website: www.americanelectriclighting.com Catalog Number Arm EPA (sq. ft.) Weight (lbs.) ACR2 ACR3 ACR4 ACR5 ACR6 1.74 2.73 3.97 5.95 7.37 30.0 47.0 68.0 103.0 127.0 SPRTS Crossarm Options For Round Tapered Steel Sportslighting Poles P R O D U C T Tubular Crossarms for Steel Poles O V E R V I E W Tubular Crossarms For Steel Poles Projected area is for the crossarm only. The crossarm projected area is added to the luminaire projected area to get a total effective projected area (EPA). CR8 8-Fixture Crossarm CR7 CR6 7-Fixture Crossarm 6-Fixture Crossarm CR5 CR4 5-Fixture Crossarm 4-Fixture Crossarm CR3 CR2 3-Fixture Crossarm 2-Fixture Crossarm Catalog Number EPA (sq. ft.) Weight (lbs.) CR2 CR3 CR4 CR5 CR6 CR7 CR8 1.28 2.45 3.21 4.17 5.13 6.10 7.06 44.0 65.0 98.0 116.0 150.0 176.0 271.0 Product Guide 215 RTAU Anchor Base Poles / Mounting Arm Combo Round Tapered Aluminum Pole with Mounting Arm P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N Intended Use 20’ to 40’ fixture mounting. Pole Grounding System — A ground lug located immediately inside the handhole is tapped for 3/8"-16 UNC ground bolt (provided by others). Features Pole Installation — Anchor bolts — Top portion of anchor bolt is galvanized per ASTM A-153. Made of steel rod having a minimum yield strength of 55,000 psi. Pole Construction — Spun-tapered seamless 6063 alloy aluminum tubing, heat-treated to produce a T6 temper. Circumferential satinbrushed finish. The shaft is cone-tapered to the butt diameter. 3 sections cast from A356 alloy aluminum, the anchor base is heattreated to a T6 condition. The anchor base telescopes the pole shaft and is circumferentially welded at both the top and the bottom. Mounting Arm Construction — Body of the mounting arm is tapered aluminum alloy 6063-T6 tube with a 2-3/8" O.D. (2" NPS) pipe size at the luminaire end. The pole end of the arm is welded to an aluminum alloy 6063-T6 mounting plate. A nominal 3" x 5" or 4" x 6" reinforced flush-covered handhole is centered 18" above the base. Welding follows AWS and CSA standards. Arms are chemically cleaned after fabrication. Removable cast aluminum top cap provided. Mounting — The mounting plate is designed to be bolted to the shaft using four 1/2" stainless steel bolts, nuts and washers. A grommet is provided for the 1-1/4" diameter wiring hole between the pole shaft and the bracket arm. All screws, nuts and bolts are made of stainless steel. A356 nut covers are included with each anchor base unless otherwise specified. Mounting Arm Finish — Satin aluminum is standard. Optional polyester powder paint and anodized finishes available. Pole Finish — Brushed aluminum (BA) is standard. Optional polyester powder paint and anodized finishes available. Example: R T A U 2 0 6 G B M A U S 8 V D B A A E L Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, please add AEL after the last option RTAU Shaft/arm type Fixture Mounting Height RTAU 20 - 40 feet (See Chart Opposite) Nominal Shaft Base Size/ Wall Thickness Options Mounting BMA (See Chart Opposite) Bolt-on Mast Arm Arm Length4 Notes: 1 Specify location and orientation when ordering option. For 1st "x": Specify the height in feet above base of pole. Use two digits to specify height: Example: 5ft = 05 and 20ft = 20 For 2nd "x": Specify orientation from handhole (A,B,C,D) Refer to the Handhole Orientation diagram on this page. 2 Horizontal arm is 18" x 2-3/8" O.D. tenon standard. 3 Other colors available, please contact local AEL representative. 4 Some restrictions apply, see back page for details. US4 US6 US8 4' Arm Length 6' Arm Length 8' Arm Length Shipped Installed L/AB Less Anchor Bolts FBC Full Base Cover VD Vibration Damper TP Tamper Proof HAAxx1,2 Horizontal Arm Bracket (1 fixture) FDLxx1 Festoon Outlet Less Electrical 12CPxx1 1/2" Coupling 34CPxx1 3/4" Coupling 1CPxx1 1" Coupling 12NPxx1 1/2" Threaded Nipple 34NPxx1 3/4" Threaded Nipple 1NPxx1 1" Threaded Nipple HHxx1 Extra Handhole Arm located on side B Handhole 216 Product Guide For more information please visit our website: www.americanelectriclighting.com Architectural Colors (powder finish)3 Standard Colors BA Brushed Aluminum (std) DDB Dark Bronze DWH White DBL Black Class 1 Arch. Anodize ABL Black ADB Dark Bronze ANA Natural RTAU Anchor Base Poles / Mounting Arm Combo Round Tapered Aluminum Pole with Twin Mounting Arms P R O D U C T O V E R V I E W Intended Use / O R D E R I N G I N F O R M AT I O N 20’ to 40’ fixture mounting. Pole Grounding System — A ground lug located immediately inside the handhole is tapped for 3/8"-16 UNC ground bolt (not supplied). Features Pole Installation — Anchor bolts — Top portion of anchor bolt is galvanized per ASTM A-153. Made of steel rod having a minimum yield strength of 55,000 psi. Pole Construction — Spun-tapered seamless 6063 alloy aluminum tubing, heat-treated to produce a T6 temper. Circumferential satinbrushed finish. The shaft is cone-tapered to the butt diameter. Mounting Arm Construction — Body of the mounting arm is tapered aluminum alloy 6063-T6 tube with a 2-3/8" O.D. (2" NPS) pipe size at the luminaire end. The pole end of the arm is welded to an aluminum alloy 6063-T6 mounting plate.Welding follows AWS and CSA standards. Arms are chemically cleaned after fabrication. Cast from A356 alloy aluminum, the anchor base is heat-treated to a T6 condition. The anchor base telescopes the pole shaft and is circumferentially welded at both the top and the bottom. Mounting — The mounting plate is designed to be bolted to the shaft using four 1/2" stainless steel bolts, nuts and washers. A grommet is provided for the 1-1/4" diameter wiring hole between the pole shaft and the bracket arm. A nominal 3" x 5" or 4" x 6" reinforced flush-covered handhole is centered 18" above the base. Cast aluminum cap provided. Mounting Arm Finish — Satin aluminum is standard. Optional polyester powder paint and anodized finishes available. All screws, nuts and bolts are made of stainless steel. A356 nut covers are included with each anchor base unless otherwise specified. Pole Finish — Brushed aluminum (BA) is standard. Optional polyester powder paint and anodized finishes available. Example: R T A U 2 0 6 G B M A 2 U S 4 B A V D A E L Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option RTAU Shaft/Arm Type Fixture Mounting Height RTAU 20 - 40 feet (See Chart Opposite) Nominal Shaft Base Size/ Wall Thickness Options Mounting BMA Bolt-on Mast Arm (See Chart Opposite) Arm Length4 Notes: 1 Specify location and orientation when ordering option. For 1st "x": Specify the height in feet above base of pole. Use two digits to specify height: Example: 5ft = 05 and 20ft = 20 For 2nd "x": Specify orientation from handhole (A,B,C,D) Refer to the Handhole Orientation diagram on this page. 2 Horizontal arm is 18" x 2-3/8" O.D. tenon standard. 3 Other colors available, please contact your local American Electric Lighting representative. 4 Some restrictions apply, see chart for details. 2US4 2US6 2US8 4' Arm Length 6' Arm Length 8' Arm Length Shipped Installed L/AB Less Anchor Bolts FBC Full Base Cover VD Vibration Damper TP Tamper Proof HAAxx1,2 Horizontal Arm Bracket (1 fixture) FDLxx1 Festoon Outlet Less Electrical 12CPxx1 1/2" Coupling 34CPxx1 3/4" Coupling 1CPxx1 1" Coupling 12NPxx1 1/2" Threaded Nipple 34NPxx1 3/4" Threaded Nipple 1NPxx1 1" Threaded Nipple HHxx1 Extra Handhole Architectural Colors (Powder Finish)3 Standard Colors BA Brushed Aluminum (std) DDB Dark Bronze DWH White DBL Black Class 1 Arch. Anodize ABL Black ADB Dark Bronze ANA Natural Arms located on sides B & D Handhole Product Guide 217 RTAU Anchor Base Poles / Mounting Arm Combo Round Tapered Aluminum Pole with Twin Mounting Arms P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N Technical Information EPA (ft2) with 1.3 gust 218 AEL Catalog Number Fixture Mtg. Height1 (feet) Mtg. Arm length (feet) Pole Shaft Diam. (in. x in.) RTAU 20 6G BMA 2US4 RTAU 20 6G BMA 2US6 RTAU 20 6E BMA 2US8 RTAU 20 6E BMA 2US4 RTAU 20 6E BMA 2US6 RTAU 20 6E BMA 2US8 RTAU 25 6G BMA 2US4 RTAU 25 6E BMA 2US6 RTAU 25 7E BMA 2US6 RTAU 25 7E BMA 2US4 RTAU 25 7E BMA 2US6 RTAU 25 7E BMA 2US8 RTAU 30 8G BMA 2US4 RTAU 30 8G BMA 2US6 RTAU 30 8G BMA 2US8 RTAU 30 8E BMA 2US4 RTAU 30 8E BMA 2US6 RTAU 30 8E BMA 2US8 RTAU 30 7E BMA 2US4 RTAU 30 7E BMA 2US6 RTAU 30 7E BMA 2US8 RTAU 35 8G BMA 2US4 RTAU 35 8G BMA 2US6 RTAU 35 8J BMA 2US4 RTAU 35 8J BMA 2US6 RTAU 35 8J BMA 2US8 RTAU 35 8E BMA 2US6 RTAU 35 8E BMA 2US8 RTAU 40 8G BMA 2US8 RTAU 40 8L BMA 2US6 RTAU 40 8J BMA 2US6 RTAU 40 8J BMA 2US8 RTAU 40 8J BMA 2US4 20' 20' 20' 20' 20' 20' 25' 25' 25' 25' 25' 25' 30' 30' 30' 30' 30' 30' 30' 30' 30' 35' 35' 35' 35' 35' 35' 35' 40' 40' 40' 40' 40' 4' 6' 8' 4' 6' 8' 4' 6' 6' 4' 6' 8' 4' 6' 8' 4' 6' 8' 4' 6' 8' 4' 6' 4' 6' 8' 6' 8' 8' 6' 6' 8' 4' 4" x 6" 4" x 6" 4" x 6" 4" x 6" 4" x 6" 4" x 6" 4" x 6" 4" x 7" 4" x 7" 4" x 7" 4" x 7" 4" x 7" 4.5" x 8" 4.5" x 8" 4.5" x 8" 4.5" x 8" 4.5" x 8" 4.5" x 8" 4.5" x 7" 4.5" x 7" 4.5" x 7" 4.5" x 8" 4.5" x 8" 4.5" x 8" 4.5" x 8" 4.5" x 8" 4.5" x 8" 4.5" x 8" 4.5" x 8" 4.5" x 8" 4.5" x 8" 4.5" x 8" 4.5" x 8" Product Guide Wall thickness (in.) 0.188 0.188 0.188 0.156 0.156 0.156 0.188 0.156 0.188 0.156 0.156 0.156 0.188 0.188 0.188 0.156 0.156 0.156 0.156 0.156 0.156 0.188 0.188 0.250 0.250 0.250 0.156 0.156 0.188 0.219 0.250 0.250 0.250 (Max per arm) EPA ft2 with 1.3 gust 80 mph 90 mph 100 mph 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1.9 0.8 1.3 1.8 2 2 1.8 0.7 2 2 2 2 1.8 0.8 2 1.8 2 1.8 1.3 2 2 2 1.3 2 2 2 1.9 0.9 2 2 1.9 0.8 1.5 0.9 n/a 0.6 0.8 1.5 1.3 0.8 n/a 2 1.9 0.9 1.3 0.8 n/a 1.3 0.8 0.9 0.8 n/a 2 2 1.1 n/a 1.1 1.3 2 0.8 n/a 1.4 For more information please visit our website: www.americanelectriclighting.com Max. Weight per arm (lbs.) Bolt Circle (in.) Bolt Size (inches) App. Ship Weight (pounds) 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 9-10 9-10 9-10 9-10 9-10 9-10 9-10 9-10 10-11 10-11 10-11 10-11 11-12 11-12 11-12 11-12 11-12 11-12 10-11 10-11 10-11 11-12 11-12 11-12 11-12 11-12 11-12 11-12 11-12 11-12 11-12 11-12 11-12 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 3/4 x 30 x 3 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 42 1 x 36 x 42 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 107 110 112 94 97 99 117 120 135 144 147 134 183 186 188 160 163 165 156 159 161 14 17 263 266 268 190 192 241 271 301 303 298 RTAU Anchor Base Poles / Mounting Arm Combo Round Tapered Aluminum Pole with Twin Mounting Arms P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N 1. Denotes fixture mounting heights, NOT nominal pole height. Shaft Base Size Bolt Circle A Bolt Projection B 6" 7" 8" 9"–10" 10"–11" 11"–12" 3-1/2" 4-1/8" 4-1/4" Base Warehouse Square Anchor Bolt C Description Template Number 10" 10-1/2" 11-1/2" PJ50033 PJ50034 PJ50035 AB30-0 AB36-0 AB36-0 IMPORTANT: • Do not erect poles without having fixtures installed. • Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use factory template. • If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. • Installation requires grout be packed under base to ensure full contact with foundation. Peripherally reinforced handhole door Cast aluminum nut cover Grout 18” B IMPORTANT: • These specifications are intended for general purposes only. American Electric Lighting reserves the right to change material or design, without prior notice, in a continuing effort to upgrade its products. Product Guide 219 RTSU Anchor Base Poles / Mounting Arm Combo Round Tapered Steel Pole with Single Mounting Arm P R O D U C T O V E R V I E W / O R D E R I N G Intended Use I N F O R M AT I O N Pole Finish — Galvanized Steel (GALV) is standard. Optional polyester powder paint finishes available. 20’ to 40’ fixture mounting. Pole Grounding System — A ground lug is located immediately inside the handhole rim. Features Pole Construction — Weldable-grade hot-rolled, commercial-quality carbon steel tubing with a minimum yield of 55,000 psi. Uniform wall thickness of 11-gauge (0.1196") or 7-gauge (0.1793"). Shafts are onepiece construction with a full-length longitudinal high-frequency resistance weld. Round in cross-section having a uniform taper of approximately .14" per foot. Anchor base is fabricated from hot-rolled carbon steel plate that conforms to ASTM A36. A reinforced handhole having nominal dimensions of 3" x 5" for shafts less than 6.25" base diameter and 4" x 6.5" for all other shafts. Cover with attachment screws included. Handhole is located 18" above the base. Pole Installation — Anchor bolts — Fabricated from commercialquality, hot-rolled carbon steel with minimum yield strength of 55,000 psi. Bolts have an "L" bend on one end. Mounting Arm Construction — Body is 2-3/8" O.D. (2" NPS) galvanized steel tube (sch. 40 material, min. yield strength 36,000 psi). Welding follows AWS standards. Arms are galvanized after fabrication. Mounting Arm Hardware — Mounting plate is designed to be bolted to the shaft using a 1/2" steel bolt Simplex mount. Single-bolt (US4, US6, US8) or multi-bolt design (US10, US12). Mounting Arm Finish — Galvanized Steel (GALV) is standard. Optional polyester powder paint finishes available. Weatherproof, removable top cap provided. Fasteners are high-strength galvanized zinc-plated or stainless steel. Example: R T S U 2 5 S M P U S 4 G A L V V D A E L Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option RTSU Shaft/arm type Fixture mounting height Nominal Shaft base size/ wall thickness 20 - 40 feet (See Chart Opposite) (See Chart Opposite) RTSU Notes: 1 Specify location and orientation when ordering option. For 1st "x": Specify the height in feet above base of pole. Use two digits to specify height: Example: 5ft = 05 and 20ft = 20 For 2nd "x": Specify orientation from handhole (A,B,C,D) Refer to the Handhole Orientation diagram on this page. 2 Horizontal arm is 18" x 2-3/8" O.D. tenon standard. 3 Other colors available, please contact your local American Electric Lighting representative. 4 Some restrictions may apply, see chart for details. 220 Product Guide Options Mounting / Arm Length4 SMP US4 Single-bolt Simplex Mount, 4' Arm Length SMP US6 Single-bolt Simplex Mount, 6' Arm Length SMP US8 Single-bolt Simplex Mount, 8' Arm Length MSMP US10 Multi-bolt Simplex Mount , 10' Arm Length MSMP US12 Multi-bolt Simplex Mount , 12' Arm Length Shipped Installed L/AB Less Anchor Bolts FBC Full Base Cover VD Vibration Damper TP Tamper Proof HASxx1,2 Horizontal Arm Bracket (1 fixture) FDLxx1 Festoon Outlet Less Electrical 12CPxx1 1/2" Coupling 34CPxx1 3/4" Coupling 1CPxx1 1" Coupling 12NPxx1 1/2" Threaded Nipple 34NPxx1 3/4" Threaded Nipple 1NPxx1 1" Threaded Nipple HHxx1 Extra Handhole For more information please visit our website: www.americanelectriclighting.com Architectural Colors (powder finish)3 Standard Colors GALV Galvanized Finish (std) DDB Dark Bronze DWH White DBL Black RTSU Anchor Base Poles / Mounting Arm Combo Round Tapered Steel Pole with Single Mounting Arm P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N Technical Information EPA (ft2) with 1.3 gust Fixture Mtg. Height1 (feet) AEL Catalog Number RTSU 20 5-9B SMP US4 RTSU 20 5-9B SMP US6 RTSU 20 5-9B SMP US8 RTSU 25 5-9B SMP US4 RTSU 25 5-9B SMP US6 RTSU 25 5-9B SMP US8 RTSU 20 6-5B SMP US4 RTSU 20 6-5B SMP US6 RTSU 20 6-5B SMP US8 RTSU 25 7B SMP US4 RTSU 25 7B SMP US6 RTSU 25 7B SMP US8 RTSU 25 7B MSMP US10 RTSU 25 7B MSMP US12 RTSU 30 8B SMP US4 RTSU 30 8B SMP US6 RTSU 30 8B SMP US8 RTSU 30 8B MSMP US10 RTSU 30 8B MSMP US12 RTSU 35 8-5B SMP US4 RTSU 35 8-5B SMP US6 RTSU 35 8-5B SMP US8 RTSU 35 8-5B MSMP US10 RTSU 35 8-5B MSMP US12 RTSU 40 9B SMP US4 RTSU 40 9B SMP US6 RTSU 40 9B SMP US8 RTSU 40 9F MSMP US10 RTSU 40 9F MSMP US12 20' 20' 20' 25' 25' 25' 20' 20' 20' 25' 25' 25' 25' 25' 30' 30' 30' 30' 30' 35' 35' 35' 35' 35' 40' 40' 40' 40' 40' Mtg. Arm length (feet) Pole Base Diameter (.14 taper rate) Wall thickness (in.) 4' 6' 8' 4' 6' 8' 4' 6' 8' 4' 6' 8' 10' 12' 4' 6' 8' 10' 12' 4' 6' 8' 10' 12' 4' 6' 8' 10' 12' 5.9" 5.9" 5.9" 5.9" 5.9" 5.9" 6.5" 6.5" 6.5" 6.8" 6.8" 6.8" 6.8" 6.8" 8" 8" 8" 8" 8" 8.5" 8.5" 8.5" 8.5" 8.5" 9" 9" 9" 9" 9" 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.120 0.180 0.180 (Max per arm) Max Weight EPA ft2 w/ 1.3 gust up to per arm 100 mph (lbs) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 76 Bolt Circle (in.) Bolt Size (inches) 9 9 9 9 9 9 9.5 9.5 9.5 10.5 10.5 10.5 10.5 10.5 11 11 11 11 11 11.5 11.5 11.5 11.5 11.5 12.5 12.5 12.5 12.5 12.5 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1 x 36 x 4 1.25 x 42 x 6 1.25 x 42 x 6 1. Denotes fixture mounting heights, NOT nominal pole height. Shaft Base Size Bolt 1 Circle A Bolt Projection B Base Square C Warehouse Anchor Bolt Description Template Number 5.9" B 6.5" B 7.0" B 8.0" B 8.5" B 9.0" B 9.0" F 9" 9.5" 10" 11" 11.5" 12.5" 12.5" 3-1/2"–4-1/4" 3-1/2"–4-1/4" 3-1/2"–4-1/4" 3-1/2"–4-1/4" 3-3/4"–4-1/2" 3-3/4"–4-1/2" 4-1/2"–5-1/4" 10" 10-1/2" 10-7/8" 11-1/2" 12" 12-3/8" 12-3/8" AB36-0 AB36-0 AB36-0 AB36-0 AB36-0 AAB36-0 N/A PJ50075 PJ50074 PJ50077 PJ50079 PJ50082 PJ50085 PJ50086 IMPORTANT: • Do not erect poles without having fixtures installed. • Factory-supplied templates must be used when setting anchor bolts. American Electric Lighting will not accept claim for incorrect anchorage placement due to failure to use factory template. • If poles are stored outside, all protective wrapping must be removed immediately to prevent finish damage. • Installation requires grout be packed under base to ensure full contact with foundation. IMPORTANT: • These specifications are intended for general purposes only. American Electric Lighting reserves the right to change material or design, without prior notice, in a continuing effort to upgrade its products. Product Guide 221 AMAW / SMAW AMAW: Aluminum Mounting Arm, Wood Poles SMAW: Steel Mounting Arm, Wood Poles P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N Steel — Body is galvanized steel tube (per ASTM A-123) constructed from A500 Grade B steel. Base is 3/16" plate. Intended Use Mounting roadway fixtures to wood poles. Welding follows AWS standards. Arms are galvanized after fabrication. Features Finish — Satin aluminum or galvanized steel is standard. Optional polyester powder finishes available. Construction Aluminum — Body is schedule 10 (T14) or schedule 40 (T20) aluminum pipe 6005-T5. Base is 3/8" aluminum plate. Hardware not included Welding follows AWS standard. Arms are pressure-washed after fabrication. Example: A M A W T 2 0 U S 4 S A A E L Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option Pipe Size Series AMAW SMAW T14 T20 Arm Length (feet) 1 - 2/3” O.D. (1 - 1/4” NPS) 2 - 3/8” O.D. (2” NPS) US2-5 US4 US6 US8 2-1/2' Arm Length 4' Arm Length 6' Arm length2 8' Arm Length2 Notes: 1 Other colors available, please contact your local American Electric Lighting representative. 2 Not available with AMAWT14. 222 Product Guide For more information please visit our website: www.americanelectriclighting.com Options Standard Finish SA Satin Aluminum (standard w/ AMAW) GALV Galvanized Steel (standard w/ SMAW) Architectural Colors (powder finish)1 Standard Colors DDB Dark Bronze DWH White DBL Black AMAW / SMAW AMAW: Aluminum Mounting Arm, Wood Poles SMAW: Steel Mounting Arm, Wood Poles P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N AMAW / SMAW AEL Catalog Number Nominal Arm Length (feet) Dimensions (inches) A B C Weight (pounds) (Max per arm) EPA ft2 w/ 1.3 gust up to 100mph Max Weight per arm (lbs) AMAW T14 US2-5 AMAW T14 US4 AMAW T14 US6 AMAW T20 US2-5 AMAW T20 US4 AMAW T20 US6 AMAW T20 US8 2'6" 4' 6' 2'6" 4' 6' 8' 30" 42" 66" 30" 42" 66" 90" 15" 19" 24" 15" 10" 24" 30" 10" 10" 12" 10" 10" 12" 15" 3 4 6 6 7 10 12 2 2 2 2 2 2 2 76 76 76 76 76 76 76 SMAW T14 US2-5 SMAW T14 US4 SMAW T14 US6 SMAW T14 US8 SMAW T20 US2-5 SMAW T20 US4 SMAW T20 US6 SMAW T20 US8 2'6" 4' 6' 8' 2'6" 4' 6' 8' 30" 42" 66" 90" 30" 42" 66" 90" 15" 19" 24" 30" 15" 19" 24" 30" 10" 10" 12" 15" 10" 10" 12" 15" 9 11 15 20 15 18 24 30 2 2 2 2 2 2 2 2 76 76 76 76 76 76 76 76 IMPORTANT: CAUTION: • These specifications are intended for general purposes only. American Electric Lighting reserves the right to change material or design, without prior notice, in a continuing effort to upgrade its products. • The arms described herein are designed for applications in areas of normal winds. Consult the factory prior to the design of systems to be mounted on structures such as bridges or buildings, or areas known to have abnormal winds such as airports or coastal areas. Failure to consider these factors in the system design could result in the failure of the pole or mast arm, and consequently personal injury or property damage. A C B .562" Dia. Product Guide 223 AMAC / SMAC AMAC: Aluminum Mounting Arm, Concrete Poles SMAC: Steel Mounting Arm, Concrete Poles P R O D U C T O V E R V I E W / O R D E R I N G Intended Use I N F O R M AT I O N Steel — Body is galvanized steel tube (per ASTM A-123) constructed from A500 Grade B steel. Base is 3/16" plate. Mounting roadway fixtures to concrete poles. Welding follows AWS standards. Arms are galvanized after fabrication. Features Construction Finish — Satin aluminum or galvanized steel is standard. Optional polyester powder paint finishes available. Aluminum — Body is schedule 10 (T14) or schedule 40 (T20) aluminum pipe 6005-T5. Base is 3/8" aluminum plate. Hardware not included Welding follows AWS standard. Arms are pressure-washed after fabrication. Example: A M A C T 2 0 U S 4 S A A E L Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option Pipe Size Series AMAC SMAC T14 T20 1 - 2/3” O.D. (1 - 1/4” NPS) 2 - 3/8” O.D. (2” NPS) US4 US6 US8 Arm Length (feet) Options 4' Arm length 6' Arm Length2 8' Arm Length2 Standard Finish SA Satin Aluminum (standard w/ AMAW) GALV Galvanized Steel (standard w/ SMAW) Architectural Colors (powder finish)1 Standard Colors DDB Dark Bronze DWH White DBL Black Notes: 1 Other colors available, please contact your local American Electric Lighting representative. 2 Not available with AMAWT14. 224 Product Guide For more information please visit our website: www.americanelectriclighting.com AMAC / SMAC AMAC: Aluminum Mounting Arm, Concrete Poles SMAC: Steel Mounting Arm, Concrete Poles P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N AMAW / SMAW AEL Catalog Number Nominal Arm Length (feet) Dimensions (inches) A B C Weight (pounds) (Max per arm) EPA ft2 w/ 1.3 gust up to 100mph Max Weight per arm (lbs) 76 AMAC T14 US4 AMAC T20 US4 AMAC T20 US6 AMAC T20 US8 4' 4' 6' 8' 42" 42" 66" 90" 18" 18" 24" 30" 10" 10" 12" 15" 6 8 11 14 2 276 2 276 SMAC T14 US4 SMAC T14 US6 SMAC T14 US8 SMAC T20 US4 SMAC T20 US6 SMAC T20 US8 4' 6' 8' 4' 6' 8' 42" 66" 90" 42" 18" 24" 30" 18" 66" 30" 10" 12" 15" 10" 24" 15" 13 17 21 18 12" 30 2 276 2 2 24 2 90" IMPORTANT: • These specifications are intended for general purposes only. American Electric Lighting reserves the right to change material or design, without prior notice, in a continuing effort to upgrade its products. 76 76 76 76 276 76 CAUTION: • The arms described herein are designed for applications in areas of normal winds. Consult the factory prior to the design of systems to be mounted on structures such as bridges or buildings, or areas known to have abnormal winds such as airports or coastal areas. Failure to consider these factors in the system design could result in the failure of the pole or mast arm, and consequently personal injury or property damage. Product Guide 225 SMAWL Mounting Arm Steel Mounting Arm, Wall Mount P R O D U C T O V E R V I E W / O R D E R I N G Intended Use I N F O R M AT I O N Finish galvanized steel is standard. Optional polyester powder paint finishes available. Wall-mounting roadway fixtures Hardware not included Features Construction — Body is galvanized steel tube (per ASTM A-123) constructed from A500 Grade B steel. Welding follows AWS standards. Arms are galvanized after fabrication. Example: S M A W L T 2 0 U S 4 G A L V A E L Ordering Information: Choose the boldface catalog nomenclature that best suits your needs and write it in the appropriate blank, then add AEL after the last option SMAWL Pipe Size Series SMAWL T14 T20 1 - 2/3” O.D. (1 - 1/4” NPS) 2 - 3/8” O.D. (2” NPS) US2-5 US4 US6 US8 Arm Length (feet) Options 2 1/2'Arm Length 4' Arm Length 6' Arm Length2 8' Arm Length2 Standard Finish GALV Galvanized Steel (standard w/ SMAW) Architectural Colors (powder finish)1 Standard Colors DDB Dark Bronze DWH White DBL Black Notes: 1 Other colors available, please contact your local American Electric Lighting representative. 2 Not available with AMAWT14. 226 Product Guide For more information please visit our website: www.americanelectriclighting.com SMAWL Mounting Arm Steel Mounting Arm, Wall Mount P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N AMAW / SMAW AEL Catalog Number Nominal Arm Length (feet) SMAWL T14 US2-5 SMAWL T14 US4 SMAWL T14 US6 SMAWL T20 US2-5 SMAWL T20 US4 SMAWL T20 US6 SMAWL T20 US8 2'6" 4' 6' 2'6" 4' 6' 8' Dimensions (inches) A B C 30" 42" 66" 30" 42" 15" 19" 24" 15" 19" 66" 30" 10" 10" 12" 10" 10" 24" 15" 90" Weight (pounds) (Max per arm) EPA ft2 w/ 1.3 gust up to 100mph Max Weight per arm (lbs) 11 13 18 17 22 12" 38 2 2 2 2 2 30 2 76 76 76 76 76 276 76 IMPORTANT: CAUTION: • These specifications are intended for general purposes only. American Electric Lighting reserves the right to change material or design, without prior notice, in a continuing effort to upgrade its products. • The arms described herein are designed for applications in areas of normal winds. Consult the factory prior to the design of systems to be mounted on structures such as bridges or buildings, or areas known to have abnormal winds such as airports or coastal areas. Failure to consider these factors in the system design could result in the failure of the pole or mast arm, and consequently personal injury or property damage. .562 Diameter (4 PLCS.) A 1" C 1" 1/4" Plate 14" 12" B 2" 1/4" x 2" Flat Bar 4" Product Guide 227 Traditional Wood Pole Arms Mast Arms & Brackets - Upsweep Arms (For Horizontally Mounted Luminaires) P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N Wood Pole Mounting Catalog Number 91-2401 92-2401 91-3001 92-3001 91-4801 92-4801 91-4802 92-4802 92-7201 91-7202 92-7202 94-9602 93-7201 94-7201 93-7202 94-9601 93-9602 228 Product Guide Item 2' ARM -11/4 '' Aluminum, (Use with Nema Head only) Dimensions: A-24'', B-123/4'', C-73/8'' 2' ARM -11/4'' Steel, Class E Dimensions: A-24'', B-123/4'', C- 73/8'' 21/2' ARM -11/4'' Aluminum, (Use with NEMA head only) Dimensions: A-27'', B-123/4'', C-73/8'' 21/2' ARM -11/4'' Steel, Class E Dimensions: A-27'', B-123/4'', C-73/8'' 4' ARM -11/4'' Aluminum, Class B Dimensions: A-43'', B-213/4'', C-87/8'' 4' ARM -11/4'' Steel, Class E Dimensions: A-43'', B-211/2'', C-85/8'' 4' ARM -2'' Aluminum, Class D Dimensions: A-43'', B-211/4'', C-85/8'' 4' ARM -2'' Steel, Class E Dimensions: A-43'', B-211/2'', C-87/8'' 6' ARM -11/4'' Steel, Class C Dimensions: A-661/4'', B-291/2'', C-83/8'' 6' ARM -2'' Aluminum, Class B Dimensions: A-661/4'', B-291/2'', C-83/8'' 6' ARM -2'' Steel, Class D Dimensions: A-661/4'', B-291/2'', C-83/4'' 8' ARM -2'' Steel, Class D Dimensions: A-901/4'', B-297/8'', C-81/2'' 6' ARM -11/4'' Aluminum, Class B Dimensions: A-661/4'', B-291/2'', C-83/4'' 6' ARM -11/4'' Steel, Class E Dimensions: A-661/4'', B-291/2'', C-83/4'' 6' ARM -2'' Aluminum, Class D Dimensions: A-661/4'', B-29'', C-77/8'' 8' ARM -11/4'' Steel, Class C Dimensions: A-901/4'', B-291/2'', C-83/4'' 8' ARM -2'' Aluminum, Class B Dimensions: A-901/4'', B-291/2'', C-77/8'' For more information please visit our website: www.americanelectriclighting.com Approx. Wt. (Lbs.) 1-3/4 5-1/2 2 6 3-3/4 10 6-1/2 17-1/2 17-1/2 9 25-1/2 40 6-3/4 18 11 26-1/2 13-1/2 Traditional Concrete Pole Arms Mast Arms & Brackets - Upsweep Arms (For Horizontally Mounted Luminaires) P R O D U C T O V E R V I E W / O R D E R I N G I N F O R M AT I O N Concrete Pole Mounting Catalog Approx. Item Number 90-2001 20” ARM -1¼'' Steel, Class E Dimensions: A-20'', B-15'', C-12'' 4' ARM -1¼'' Steel, Class E Dimensions: A-48'', B-25'', C-12'' 6' ARM -2'' Steel, Class D Dimensions: A-72'', B-34'', C-12'' 8' ARM -2'' Steel, Class D Dimensions: A-96'', B-34'', C-12'' 90-4801 90-7202 90-9602 Wt. (Lbs.) 10 16 29 48 Notes: 1. CLASS CHART — Denotes the maximum size luminaire recommended for use. Both weight and projected area must be considered. Classifications based on American Electric Lighting standards. See Isotach Wind Map, page 189. Luminaire Class Weight (in pounds) Effective Projected Area A 30 1.5 B 40 2.0 C 60 3.0 D 80 4.0 E 100 5.0 2. Steel mast arms constructed in accordance with ASTM specification A-36. 3. For more information, please contact your local American Electric Lighting representative. CAUTION: The poles and mast arms described herein are designed for ground mounted applications in areas of normal winds. Consult the factory prior to the design of systems to be mounted on structures such as bridges or buildings, or areas known to have abnormal winds such as airports or coastal areas. Failure to consider these factors in the system design could result in the failure of the pole or mast arm, and consequently personal injury or property damage. Product Guide 229 NOTES 230 Product Guide For more information please visit our website: www.americanelectriclighting.com TECHNICAL DATA, TERMS AND CONDITIONS HPS Replacement Starters...................................232 Lamp Selection .......................................................233 Fuse Ratings ....................................................234-239 Luminaire Classification Systems........................240 Floodlighting Applications. ...................................241 Floodlighting Calculations.....................................242 Roadway Lighting Calculations............................243 Terms & Conditions ........................................244-245 Index .................................................................246-247 For technical support, please call: 1-800-754-0463 or email: AELtechsupport@americanelectriclighting.com www.americanelectriclighting.com 231 Technical Data H P S R E P L A C E M E N T S T A R T E R S Catalog Number Description IGN 3L 36 OB 50/150 3 Lead 3/16” Terminal Open Board 55V IGN 3L 36 OB 200/400 3 Lead 3/16” Terminal Open Board 100V IGN 3L 14 OP 50/150 3 Lead 1/4” Terminal Open Plug 55V IGN 3L 14 OP 200/400 3 Lead 1/4” Terminal Open Plug 100V IGN 3L 14 EC 50/150 3 Lead 1/4” Terminal Encapsulated 55V IGN 3L 14 EC 200/400 3 Lead 1/4” Terminal Encapsulated 100V IGN 2L 36 OB 50/150 2 Lead 3/16” Terminal Open Board 55V IGN 2L 36 OB 200/400 2 Lead 3/16” Terminal Open Board 100V IGN 2L 14 OP 50/150 2 Lead 1/4” Terminal Open Plug 55V IGN 2L 14 OP 200/400 2 Lead 1/4” Terminal Open Plug 100V IGN 2L 14 EC 50/150 2 Lead 1/4” Terminal Encapsulated 55V IGN 2L 14 EC 200/400 2 Lead 1/4” Terminal Encapsulated 100V IGN 2L 36 OB DUAL 50/400 2 Lead 3/16” Terminal Open Board Dual 55/100V IGN 2L 14 OP DUAL 50/400 2 Lead 1/4” Terminal Open Plug Dual 55/100V IGN 2L 14 EC DUAL 50/400 2 Lead 1/4” Terminal Encapsulated Dual 55/100V IGN 2L 14 EC DUAL UNI 2 Lead 1/4” Terminal Encapsulated Dual Universal IGN 2L 14 OP DUAL UNI 2 Lead 1/4” Terminal Open Plug Dual Universal 1 1 1 Notes: 1 232 Product Guide Ships as 55V, converts to 100V by removing jump wire. For photometric information please visit our website: www.americanelectriclighting.com Technical Data L A M P Typical Lamp Types Lamp Comparison with Watts and Initial Lamp Lumens Quartz Incandescent Low Pressure Sodium Metal Halide High Pressure Sodium Efficiency Poor 20 LPW Best 183 LPW Good 90 LPW Better 105 LPW Mean Life Low 2K Hrs Medium 18K Hrs High 12K Hrs High 24K Hrs Lumen Maintenance High 97% High 100%(+9) Medium 80% High 90% Color Best Very Poor Monochrome Good Fair System C.U. Good Fair Good Good Hot Restart Instant 1 Minute 15 Minutes 1 Minute Warm-Up Instant 10 Minutes 10 Minutes* 5 Minutes System Cost Lowest High High High *Pulse Start MH Recommended Minimum Mounting Heights for Various Lamps High Pressure Sodium Lamp 50W 70W 100W 150W 200W 250W 310W 400W 1000W S E L E C T I O N Metal Halide Lamp 175W 400W 1000W Minimum Mounting Height (Ft) Lamp Type High Pressure Sodium Watts Initial Lumens Mean Lumens Avg. Life 35 50 70 100 150 200 250 310 400 1000 2250 4000 6300 9500 16000 22000 29000 37000 50000 130000 2025 3600 5500 8000 13800 19800 26100 32300 45000 120700 24000 24000 24000 24000 24000 24000 24000 24000 24000 24000 12800 20000 32000 32000 107800 153000 9300 14100 20500 20500 86000 127400 7500 7500 15000 15000 12000 3000 16000 23800 32000 37000 41000 120000 112000 16600 21000 28000 32800 96000 150000 15000 15000 20000 20000 20000 175 250 Metal 400 Halide 400 (BT28) (Horizontal) 1000 1500 Pulse Start Metal Halide (Horizontal) 175 250 320 350 400 1000 8.0 12.0 15.0 18.0 20.0 25.0 30.0 35.0 40.0 Maintenance Factors If maintained footcandle level is desired, multiply the area coverage per fixture by the maintenance factor. Maintenance factor is determined by multiplying the lamp lumen depreciation factor (LLD) by the luminaire dirt depreciation factor (LDD). The lamp lumen depreciation factor is usually the mean lumen value of the lamp. The luminaire dirt depreciation factor range is described in the Illuminating Engineering Society Handbook. A .9 dirt factor is commonly used. Product Guide 233 Technical Data F U S E R A T I N G S Nominal Lamp Wattage (watts) 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 07S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 10S 15S / E N E R G Y Ballast Circuit RN RH XN XN XN XH XH XH CA CA CA CA CA CT CT CT MR MR MR RN RH XN XN XN XH XH XH CA CA CA CA CA CA CT CT CT CT MR MR MR RN Supply Voltage (volts) 120 120 208 240 277 208 240 277 120 208 240 277 480 120 208 240 120 240 480 120 120 208 240 277 208 240 277 120 208 240 277 347 480 120 208 240 277 120 240 480 120 C O N S U M P T I O N Input Watts (watts) 86 86 91 91 91 91 91 91 95 95 95 95 95 95 95 95 103 103 103 115 115 130 130 130 130 130 130 138 138 138 138 138 138 130 130 130 130 138 138 138 170 Current (amps) 2.10 1.30 1.53 1.35 1.17 0.85 0.75 0.65 0.90 0.53 0.48 0.43 0.23 0.86 0.50 0.43 0.90 0.45 0.23 3.05 1.80 2.25 1.98 1.53 1.25 1.10 0.85 1.18 0.70 0.60 0.50 0.40 0.29 1.22 0.70 0.61 0.52 1.20 0.60 0.30 4.50 # of Fuses 1 1 2 2 1 2 2 1 1 2 2 1 2 1 2 2 1 2 2 1 1 2 2 1 2 2 1 1 2 2 1 1 2 1 2 2 1 1 2 2 1 Fuse Rating (Amps) 8 3 5 3 3 3 2 2 3 2 2 2 2 3 2 2 3 2 2 10 5 10 5 5 3 3 3 3 3 2 2 2 2 3 2 2 2 3 2 2 15 Notes 1 234 Product Guide Based on $.10/KWH; 12 months operation For photometric information please visit our website: www.americanelectriclighting.com Annual Energy Consumption ($)1 $37.67 $37.67 $39.86 $39.86 $39.86 $39.86 $39.86 $39.86 $41.61 $41.61 $41.61 $41.61 $41.61 $41.61 $41.61 $41.61 $45.11 $45.11 $45.11 $50.37 $50.37 $56.94 $56.94 $56.94 $56.94 $56.94 $56.94 $60.44 $60.44 $60.44 $60.44 $60.44 $60.44 $56.94 $56.94 $56.94 $56.94 $60.44 $60.44 $60.44 $74.46 Technical Data F U S E Nominal Lamp Wattage (watts) 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 15S 17M 17M 17M 17M 17M 17M 17M 17M 17M 17M 17M 17M 20S 20S 20S 20S 20S 20S 20S 20S 20S 20S Ballast Circuit RH XN XN XN XH XH XH CA CA CA CA CA CT CT CT CT MR MR MR CA CA CA CA CA CA SC SC SC SC SC SC XN XH RN RH CA CA CA CA CA CA Supply Voltage (volts) 120 208 240 277 208 240 277 120 208 240 277 480 120 208 240 277 120 240 480 120 208 240 277 347 480 120 208 240 277 347 480 120 120 240 240 120 208 240 277 347 480 R A T I N G S Input Watts (watts) 170 188 188 188 188 188 188 190 190 190 190 188 190 190 190 190 196 196 196 213 213 213 213 213 213 208 208 208 208 208 206 240 240 218 218 240 240 240 240 240 240 Current (amps) 2.35 2.88 2.52 2.25 1.60 1.40 1.25 1.65 0.95 0.82 0.72 0.42 1.76 1.01 0.88 0.76 1.70 0.90 0.40 1.80 1.10 0.90 0.78 0.62 0.51 1.80 1.05 0.90 0.80 0.65 0.45 6.27 3.48 2.80 1.56 2.22 1.28 1.11 0.96 0.77 0.56 / E N E R G Y # of Fuses 1 2 2 1 2 2 1 1 2 2 1 2 1 2 2 1 1 2 2 1 2 2 1 1 2 1 2 2 1 1 2 1 1 2 2 1 2 2 1 1 2 Fuse Rating (Amps) 8 10 10 8 5 5 5 5 3 3 3 2 5 3 3 3 5 3 2 5 3 3 2 2 2 5 3 3 3 3 2 20 10 10 5 10 5 5 3 3 2 C O N S U M P T I O N Annual Energy Consumption ($)1 $74.46 $82.34 $82.34 $82.34 $82.34 $82.34 $82.34 $83.22 $83.22 $83.22 $83.22 $82.34 $83.22 $83.22 $83.22 $83.22 $85.85 $85.85 $85.85 $93.29 $93.29 $93.29 $93.29 $93.29 $93.29 $91.10 $91.10 $91.10 $91.10 $91.10 $90.23 $105.12 $105.12 $95.48 $95.48 $105.12 $105.12 $105.12 $105.12 $105.12 $105.12 Notes: 1 Based on $.10/KWH; 12 months operation Product Guide 235 Technical Data F U S E R A T I N G S Nominal Lamp Wattage (watts) 20S 20S 20S 20S 20S 20S 20S 20S 20M 20M 20M 20M 20M 20M 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25S 25M 25M 25M 25M 25M 25M 25M 25M / E N E R G Y Ballast Circuit CT CT CT CT CT MR MR MR SC SC SC SC SC SC XN XH RN RH CA CA CA CA CA CA CT CT CT CT CT CT MR MR MR CA CA CA CA CA CA CT CT Supply Voltage (volts) 120 208 240 277 480 120 240 480 120 208 240 277 347 480 120 120 240 240 120 208 240 277 347 480 120 208 240 277 347 480 120 240 480 120 208 240 277 347 480 120 240 C O N S U M P T I O N Input Watts (watts) 235 235 235 235 235 255 255 255 232 232 232 232 232 232 287 287 282 282 295 295 295 295 295 310 300 300 300 300 300 300 310 310 310 298 298 298 298 295 295 295 295 Current (amps) 2.10 1.21 1.05 0.91 0.52 2.20 1.10 0.55 2.00 1.20 1.00 0.85 0.70 0.50 8.73 4.85 4.00 2.22 2.50 1.50 1.30 1.10 0.93 0.63 2.75 1.60 1.38 1.19 0.92 0.69 2.80 1.40 0.70 2.50 1.45 1.25 1.10 0.90 0.63 2.66 1.54 # of Fuses 1 2 2 1 2 1 2 2 1 2 2 1 1 2 1 1 2 2 1 2 2 1 1 2 1 2 2 1 1 2 1 2 2 1 2 2 1 1 2 1 2 Fuse Rating (Amps) 10 3 3 3 2 10 3 2 5 3 3 3 2 2 22 15 10 10 10 5 5 5 3 2 10 5 5 5 3 2 10 5 2 10 5 5 5 3 2 10 5 Notes: 1 236 Product Guide Based on $.10/KWH; 12 months operation For photometric information please visit our website: www.americanelectriclighting.com Annual Energy Consumption ($)1 $102.93 $102.93 $102.93 $102.93 $102.93 $111.69 $111.69 $111.69 $101.62 $101.62 $101.62 $101.62 $101.62 $101.62 $125.71 $125.71 $123.52 $123.52 $129.21 $129.21 $129.21 $129.21 $129.21 $135.78 $131.40 $131.40 $131.40 $131.40 $131.40 $131.40 $135.78 $135.78 $135.78 $130.52 $130.52 $130.52 $130.52 $129.21 $129.21 $129.21 $129.21 Technical Data F U S E Nominal Lamp Wattage (watts) 25M 25M 25M 25M 25M 31S 31S 31S 31S 31S 31S 31S 31S 32M 32M 32M 32M 32M 32M 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40S 40M Ballast Circuit CT SC SC SC SC CA CA CA CA CA MR MR MR SC SC SC SC SC SC RN RH RN RH XN XH CA CA CA CA CA CA CT CT CT CT CT CT MR MR MR CA Supply Voltage (volts) 480 120 208 240 277 120 208 240 277 480 120 240 480 120 208 240 277 347 480 208 208 240 240 120 120 120 208 240 277 347 480 120 208 240 277 347 480 120 240 480 120 R A T I N G S Input Watts (watts) 295 291 291 291 291 365 365 365 365 365 380 380 380 368 368 368 368 368 368 440 440 440 440 463 463 464 464 464 464 464 464 465 465 465 465 465 465 490 490 490 458 Current (amps) 1.33 2.50 1.45 1.25 1.10 3.37 1.94 1.68 1.45 0.84 3.30 1.65 0.83 3.25 1.90 1.65 1.40 1.10 0.80 5.20 2.89 6.00 3.33 6.70 3.72 3.80 2.20 1.90 1.70 1.32 0.97 4.20 2.40 2.10 1.82 1.45 1.05 4.20 2.10 1.05 4.00 / E N E R G Y # of Fuses 2 1 2 2 1 1 2 2 1 2 1 2 2 1 2 2 1 1 2 2 2 2 2 1 1 1 2 2 1 1 2 1 2 2 1 1 2 1 2 2 1 Fuse Rating (Amps) 5 10 5 5 5 10 5 5 5 3 10 5 3 10 5 5 5 5 2 15 10 15 10 20 10 10 10 5 5 5 3 15 10 10 5 5 5 15 10 5 10 C O N S U M P T I O N Annual Energy Consumption ($)1 $129.21 $127.46 $127.46 $127.46 $127.46 $159.87 $159.87 $159.87 $159.87 $159.87 $166.44 $166.44 $166.44 $161.18 $161.18 $161.18 $161.18 $161.18 $161.18 $192.72 $192.72 $192.72 $192.72 $202.79 $202.79 $203.23 $203.23 $203.23 $203.23 $203.23 $203.23 $203.67 $203.67 $203.67 $203.67 $203.67 $203.67 $214.62 $214.62 $214.62 $200.60 Notes: 1 Based on $.10/KWH; 12 months operation Product Guide 237 Technical Data F U S E R A T I N G S Nominal Lamp Wattage (watts) 40M 40M 40M 40M 40M 40M 40M 40M 40M 40M 40M 40M 40M 40M 40M 75S 75S 75S 75M 75M 75M 75M 75M 75M 75M X1S X1S X1S X1S X1S X1S X1M X1M X1M X1M X1M X1M X1M X1M X1M X1M / E N E R G Y Ballast Circuit CA CA CA CA CA CT CT CT CT CT CT SC SC SC SC CA CA CA CA CA CA CA SC SC SC CA CA CA CA CA CA CA CA CA CA CA CA SC SC SC SC Supply Voltage (volts) 208 240 277 347 480 120 208 240 277 347 480 120 208 240 277 120 208 240 820 820 820 820 120 208 240 120 208 240 277 347 480 120 208 240 277 347 480 120 208 240 277 C O N S U M P T I O N Input Watts (watts) 458 458 458 460 462 465 465 465 465 462 465 452 452 452 452 840 840 840 120 208 240 277 812 812 812 1100 1100 1100 1100 1100 1100 1070 1070 1070 1070 1070 1080 1080 1080 1080 1080 Current (amps) 2.30 2.00 1.75 1.40 1.00 4.00 2.31 2.00 0.87 1.35 1.00 3.80 2.20 1.90 1.65 6.75 4.00 3.50 6.90 3.85 3.45 3.00 7.00 4.00 3.50 9.50 5.50 4.75 4.15 3.30 2.30 9.00 5.20 4.50 3.90 3.20 2.25 9.00 5.20 4.50 3.90 # of Fuses 2 2 1 1 2 1 2 2 1 1 2 1 2 2 1 1 2 2 1 2 2 1 1 2 2 1 2 2 1 1 2 1 2 2 1 1 2 1 2 2 1 Fuse Rating (Amps) 10 5 5 5 3 10 10 5 3 5 3 10 10 5 5 20 10 10 20 10 10 10 20 10 10 30 15 15 15 10 10 30 15 15 10 10 10 30 15 15 10 Notes: 1 2 238 Product Guide Based on $.10/KWH; 12 months operation Based on $.10/KWH; 4 months operation For photometric information please visit our website: www.americanelectriclighting.com Annual Energy Consumption ($)1 $200.60 $200.60 $200.60 $201.48 $202.36 $203.67 $203.67 $203.67 $203.67 $202.36 $203.67 $197.98 $197.98 $197.98 $197.98 $367.92 $367.92 $367.92 $52.56 $91.10 $105.12 $121.33 $355.66 $355.66 $355.66 $481.80 $481.80 $481.80 $481.80 $481.80 $481.80 $156.222 $156.222 $156.222 $156.222 $156.222 $157.682 $157.682 $157.682 $157.682 $157.682 Technical Data F U S E Nominal Lamp Wattage (watts) X1M X1M X5M X5M X5M X5M X5M X5M Ballast Circuit SC SC CA CA CA CA CA CA Supply Voltage (volts) 347 480 120 208 240 277 347 480 R A T I N G S Input Watts (watts) 1080 1070 1605 1605 1605 1605 1615 1625 Current (amps) 3.20 2.25 13.50 7.80 6.75 5.58 4.80 3.40 / E N E R G Y # of Fuses 1 2 1 2 2 1 1 2 Fuse Rating (Amps) 10 10 N/A 20 20 15 15 10 C O N S U M P T I O N Annual Energy Consumption ($)1 $157.682 $156.222 $234.332 $234.332 $234.332 $234.332 $235.792 $237.252 Notes: 1 2 Based on $.10/KWH; 12 months operation Based on $.10/KWH; 4 months operation Product Guide 239 Technical Data L U M I N A I R E WIDTH CLASSIFICATION Mounted at Pavement Type I Center Type II Edge C L A S S I F I C A T I O N S Y S T E M S Normally Used for: TYPE I Roadways up to 2 times the mounting height in width Up to 1 times the mounting height for one side mounting Up to 2 times the mounting height for both side mounting Type III Edge Up to 1.5 times the mounting height for one side mounting Up to 3 times the mounting height for both side mounting Type IV Edge Up to 2 times the mounting height for one side mounting Up to 4 times the mounting height for both side mounting Type V Center Up to 4 times the mounting height in total width TYPE I - 4 Way TYPE II TYPE II - 4 Way 240 SPACING CLASSIFICATION Definition S Short M Medium Spacings up to 5 times mounting height L Long Spacings up to 5 times mounting height Normally Used for: Spacings up to 4 times the mounting height GLARE CONTROL CLASSIFICATION Definition FCO Full-Cutoff Strict control of light above 80 Vertical Zero emission above 90 Vertical CO Cutoff Strict control of light above 80 Vertical 2.5% emission above 90 Vertical SCO Semi-Cutoff Medium control of light above 80 Vertical NCO Non-Cutoff No control requirements above 80 Vertical Product Guide Normally Used for: For photometric information please visit our website: www.americanelectriclighting.com TYPE III TYPE IV TYPE V Technical Data F L O O D L I G H T I N G IES Classifications Setback The IES beam spreads indicate the angular ranges (horizontally and vertically) through which the intensity of the floodlight is greater than 10% of its maximum intensity. This angular range is referred to as the 'Field Angle'. For example: Asymmetrical beam spread 138° (H) x 119° (V) HORIZONTAL The recommended setback is three-fourth the building height. If a building is 30 feet tall, the recommended setback is 22.5 feet from the building. Locating the floodlight closer to the building will sacrifice uniformity; setting it farther back will result in a loss of efficiency. Setback distance = 3/4 x building height 3 /4 (30 ft.) = 22.5 ft. IES Type Beam Description Spacing 1 2 3 4 5 6 7 Sign Lighting Considerations: 1. Setback 2. Spacing 3. Aiming Setback IES Beamspread Classification 10° up to 18° 18° up to 29° 29° up to 46° 46° up to 70° 70° up to 100° 100° up to 130° 130° and up Sign Lighting When lighting a sign with ground-mounted floodlights, there are three considerations: setback, spacing and aiming. VERTICAL = IES 7 X 6 Field Angle Degrees A P P L I C A T I O N S Very Narrow Narrow Medium Narrow Medium Medium Wide Wide Very Wide The rule of thumb for spacing floodlights is not to exceed two times the setback distance. If the setback is 22.5 feet, the floodlights should not be placed more than 45 feet apart. When using ground-mounted floodlights to light a sign, the recommended setback is a distance equal to three-fourth the sign height. For example, the setback distance for a 12-foot by 6-foot sign would be 4.5 feet. Locating the floodlight closer will sacrifice uniformity while setting it farther back will result in a loss of efficiency. Setback distance = 3/4 x sign height 3 /4 (6 ft.) = 4.5 ft. Spacing = 2 x setback distance 22.5 ft. x 2 = 45 ft. apart The IES classification was formerly referred to as NEMA Type. The following outdoor design tips provide general guidelines for lighting design. These guidelines may not apply to all applications. GROUND-MOUNTED FLOODLIGHTS Ground-mounted floodlights are used to light building facades, signs and flagpoles. Facade Lighting When lighting building facades with groundmounted floodlights, three factors are considered: setback, spacing and aiming. Facade Lighting Considerations: 1. Setback 2. Spacing 3. Aiming Spacing Aiming The floodlight should be aimed at least twothirds the height of the building. For example, if a building is 30 feet high, the recommended aiming point is approximately 20 feet high. After installation is complete, aiming can be adjusted to produce the best appearance. Mounting a full or upper visor to the floodlight can reduce unwanted spill light. The rule of thumb for spacing floodlights is not to exceed two times the setback distance. If the setback is 4.5 feet, the floodlights should not be placed more than 9 feet apart. Spacing = 2 x setback distance 4.5 ft. x 2 = 9 ft. apart Aiming point = 2/3 x building height 2 /3 (30 ft.) = 20 ft. high Product Guide 241 Technical Data F L O O D L I G H T I N G Aiming The floodlight should be aimed at least twothirds up the sign. For example, if a sign is six feet tall, then the floodlight will be aimed approximately four feet high. After installation is completed, aiming can be adjusted to produce the best appearance. Mounting a full or upper visor to the floodlight can reduce unwanted glare. C A L C U L A T I O N S Spacing Spacing Ideally, three floodlights are recommended to light a flag. The floodlights should be placed approximately 120° apart. When more than one pole is added, pole placement is a concern. The "4 times" rule of thumb for spacing indicates that a pole should be placed four times the mounting height from the adjacent poles. If a flood is mounted on a 20-foot pole, space the poles 80 feet apart. 3 floodlights spaced 120° apart Pole spacing = 4 x mounting height 4 (20-ft. pole) = 80 feet between poles Aiming point = 2/3 x sign height 2/3 (6 ft.) = 4 ft. high Aiming The recommended aiming point for each floodlight is the center of the flag or the top of the pole. Mounting a full or upper visor to the floodlight can reduce unwanted spill light. Flag Lighting Ground-mounted floodlights also can be used to light flags. Setback, spacing and aiming must all be considered. Vertical Aiming A single floodlight uses the two-thirds rule of thumb for vertical aiming. The fixture is aimed 2/3 of the distance across the area to be lighted and at least 30° below horizontal. If the area to be lighted is 40 feet across, the recommended aiming point is 27 feet. Aiming point = 2/3 across distance to be lighted 2 /3 (40 ft.) = 27 ft. aiming point Flag Lighting Considerations: 1. Setback 2. Spacing 3. Aiming Setback The recommended setback for lighting a flag is one-third times the pole height. If the pole is 30 feet tall, the floodlight should be set back a distance of 10 feet away from the pole. Setback distance = 1/3 x pole height 1 /3 (30 ft.) = 10 ft. POLE-MOUNTED FLOODLIGHTS General Area Lighting Pole-mounted floodlights are commonly used for general area lighting applications such as parking lots and storage yards. Mounting height, spacing, vertical aiming and horizontal aiming should be considered. General Lighting Considerations: 1. Mtg. Height 2. Spacing 3. Vertical aiming 4. Horizontal aiming Additionally, to minimize glare, the recommended aiming point distance should never exceed twice the mounting height. If a pole is 20 feet high, the vertical aiming point should not exceed 40 feet out. 2 (20 ft. mtg. ht.) = 40 ft. Horizontal Aiming Mounting Height ' The recommended mounting height is one half the distance across the area to be lighted. If the area to be lighted is 40 feet across, the lowest recommended mounting height is 20 feet. ' Mounting height = 1/2 distance to be lighted 1 /2 (40ft.) = 20 ft. 242 Product Guide When an additional floodlight is added to a single pole, horizontal aiming also must be considered. First, each floodlight should be vertically aimed according to the two-thirds rule. As long as the floodlight has a horizontal NEMA 6 or 7 beamspread, the floodlights can be aimed up to 90° apart. Technical Data R O A D W A Y L I G H T I N G C A L C U L A T I O N S American Electric Lighting offers an extensive line of luminaires for your roadway lighting applications. The calculations which follow will help you to determine the type, quantity and placement of these luminaires. You will need data from the Photometric Test Report for the luminaire(s) being considered. Contact your American Electric Lighting representative for these reports. A sample report is provided for your use in the following calculations. Calculations Initial Lamp Coefficient of Light Loss Lumens x Utilization x Factor Average Maintained = Footcandles Pole Spacing Pole Spacing x Road Width Initial Lamp Coefficient of Light Loss Lumens x Utilization x Factor = Average Maintained Footcandles x Initial Lamp Lumens Averaged Maintained Footcandles = Coefficient Utilization Pole Spacing x x Road Width x Road Width Light Loss Factor SAMPLE CALCULATIONS A roadway is to be lighted to a level of 1fc (Average Maintained Footcandles). The roadway is 45 feet wide and the poles are 30 feet high, therefore, the mounting height ratio is 1.5 The Photometric Test Report provides: Initial Lamp Lumens = 14,000. Coefficient of Utilization (at 1.5MHR) = 43% for the 175W MH lamp used in an American Electric Lighting LUXMASTER LUMINAIRE. The Light Loss Factor provided in the preceding charts for the 175W MH lamp is 0.70. Initial Lamp Lumens are also provided in this chart. Pole Spacing = 14,000 (ILL) x .43 (CU) x .70 (LLF) = 94 Feet (PS) 1 (AMF) x 45 (RW) If Pole Spacing is known, then Average Maintained Footcandles can be calculated: Average Maintained Footcandles = 14,000 (ILL) x .43 (CU) x .70 (LLF) = .996 (AMF) 94 (PS) x 45 (RW) Or Initial Lamp Lumens can be calculated: Initial Lamp Lumens = 1 (AMF) x 94 (PS) x 45 (RW) = 14,000 (ILL) .43 (CU) x .70 (LLF) Other application data may be determined by similar calculations. Contact your local American Electric Lighting representative for assistance. AMF - Average Maintained Footcandles CU - Coefficient of Utilization ILL - Initial Lamp Lumens MHR - Mounting Height Ratio LLF - Light Loss Factor PS - Pole Spacing RW - Road Width Product Guide 243 TERMS AND CONDITIONS OF SALE For Shipments Within the United States* Effective August 25, 2008 TERMS: The words we, our and us shall refer to American Electric Lighting (“AEL”) , a division of Acuity Brands Lighting, Inc. and the words purchaser, you and your, shall refer to the person or entity purchasing products under this Agreement. PAYMENT TERMS: A 1% cash discount will be allowed on invoices paid in full by the 10th of the month following the month of billing. All payments made after the 10th are due on a net basis to the 25th (1% 10th prox, net 25th prox). FREIGHT ALLOWANCE: Shipments are F.O.B. our plants, distribution centers or field warehouses as follows: • All factory orders having a distributor price of $3,000 or more for one consignee for one release qualify for freight allowed. • Warehouse orders of stock items having a distributor price of $3,000 or more for one consignee for one release qualify for freight allowed. • All orders having a distributor price of less than $3,000 will be assessed freight and handling charges. • Anchor bolts are included with American Electric Lighting poles. Pre-shipped anchor bolts having a distributor price of less than $3,000 will be assessed freight and handling charges. We reserve the right to route all orders that qualify for freight allowance at our discretion. AEL will ship in the manner selected by the purchaser provided that the purchaser assumes all additional transportation costs. DELIVERY: AEL shall not be liable for any delay or default in delivering products for any reason beyond the reasonable control of AEL, including, but not limited to, armed conflict or economic dislocation resulting therefrom; embargoes; shortages of labor, raw materials, fuels, energy, production facilities or transportation; labor difficulties, civil disorders of any kind; action of civil or military authorities (including priorities and allocations); fires, floods, and accidents. No liability shall be incurred by AEL by reason of its not filling any order or portion thereof due to any of these or similar circumstances. TRANSPORTATION CLAIMS: AEL’s equipment is tested for mechanical defects prior to shipping. AEL’s packaging is regularly inspected by transportation authorities who assume responsibility for both apparent and concealed damages sustained by improper handling. Title passes to purchaser upon delivery by AEL to the carrier, and all claims for damages or shortages in transit shall be made by the purchaser to the delivering carrier. AEL will be glad to assist when called upon, provided notification is given in writing within 15 business days of receipt of shipment. PACKAGING: AEL reserves the right to alter the quantities of any order so as to conform to standard packaging. PRICES: Prices are subject to change without notice. In the event of price increases, all orders on hand will be filled at the lower prices provided that such orders are released for shipping prior to the effective date of the price increase. If the orders are not released for shipment prior to the effective date of the price increase, the orders will be billed at the prices in effect at the time of shipment. Special quoted orders which cannot be released for shipping prior to the price increase effective date may be subject to an increase in price. Minimum billing is $100 net excluding orders for replacement parts only. Orders for parts totaling less than $15 will be billed $15 lump sum. Prices do not include lamps unless so specified. RETURN MERCHANDISE: No merchandise may be returned without prior written authorization from AEL factories. Requests to return merchandise must be made with AEL’s agents for transmittal to the factory within four (4) months from date of shipment by AEL. All returns must be shipped prepaid to the location designated on the return authorization. Credit will be issued based on the original invoice price, or price in effect at time of return, whichever is lower, less a restocking charge of 25% (minimum) of the purchase price (to partially defray our cost of handling), less reconditioning and replacing costs if necessary, and less the freight expense of the original shipment. The reconditioning charge will be determined by the amount of repairs, refinishing or reconditioning required to restore the merchandise to saleable condition. All non-stocking, special, custom-made, outdated, or modified versions of normal factory stocking items are not returnable. Authorization will not be granted when the value of all items to be returned is less than $100. Returns from any one order will be limited to not more than 10% of the total order value. 244 Product Guide SERVICE AREA LIMITATION: AEL reserves the right to refuse to make quotations, accept orders or make shipments to points of destination outside of the regular or assigned selling and service area of the distributor. GUARANTEE: AEL warrants all equipment to be free from defect in manufacturing, under normal and proper storage, installation, and use, for a period of one (1) year. In addition we provide a six (6) year warranty on the factory installed electrical system (which consists of the ballast, ignitor, capacitor, lamp socket, terminal board, PEC receptacle, and wiring) inside AEL products. AEL’s guarantee liability extends only to the repair or replacement of the defective part, at AEL’s option, and no labor charges for correction of the defect by repair or replacement will be honored by AEL unless prior written authority has been granted by AEL’s Customer Service Department. THE FOREGOING GUARANTEE TERMS ARE EXCLUSIVE AND IN LIEU OF ALL OTHER GUARANTEES. AEL MAKES NO REPRESENTATIONS OR WARRANTIES EXCEPT AS EXPRESSLY SET FORTH IN THESE TERMS AND CONDITIONS, AND AEL EXPRESSLY DISCLAIMS ALL OTHER REPRESENTATIONS AND WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NO DISTRIBUTOR OR SUPPLIER OF AEL HAS THE AUTHORITY TO MODIFY OR AMEND THIS GUARANTEE. LIMITATION OF LIABILITY: The foregoing guarantee provides the purchaser’s sole and exclusive remedy relating to AEL’s products. The total liability of AEL on any and all claims of any kind, whether in contract, warranty, tort (including negligence), strict liability or otherwise, arising out of or in connection with, or resulting from, AEL’s performance or breach of the foregoing limited warranty or from AEL’s sale, delivery, repair, or replacement of any products, or the furnishing of any services, shall in no event exceed the purchase price allocable to the specific product which gives rise to the claim, and any and all such liability shall terminate upon the expiration of the limited warranty set forth above. IN NO EVENT SHALL AEL BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR PUNITIVE DAMAGES, EVEN IF INFORMED OF THE POSSIBILITY OF SUCH DAMAGES, WHETHER AS THE RESULT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY, OR ANY OTHER THEORY. CANCELLATION CHARGES: Orders for stocking items may be cancelled prior to shipping without charge. All other orders may not be cancelled unless AEL is reimbursed for all work already performed and for all special materials purchased by AEL. If an order is cancelled after shipment or if delivery is refused at the delivery destination, all warehousing, delivery and return costs will be charged to the purchaser. GENERAL: Possession of a price sheet does not entitle you to purchase any merchandise. Specifications are subject to change without notice. Consult factory for verification. The compliance of AEL’s product to individual project specifications and the approval for their use is not warranted by AEL. ACCEPTANCE: Acceptance of orders can be made only at AEL’s plants, distribution centers or field warehouses for warehouse orders on the basis of these terms and conditions of sale. Acceptance of orders is limited to the terms and conditions hereof. AEL hereby objects to any additional or different terms offered by the purchaser in its sales order or any other document of purchaser. Such additional or different terms shall not become a part of any order without the express written consent of AEL. ENTIRE AGREEMENT: Except as expressly agreed in writing signed by AEL, the terms and conditions stated above shall constitute the entire sales agreement between AEL and the purchaser. Any contrary or additional terms or conditions submitted by the purchaser (other than the description of the products being ordered and the requested quantities, shipping date, and shipping location contained in purchaser’s purchase order) shall be deemed to be of no force or effect and are hereby rejected. Purchaser’s submission of a purchase order shall indicate purchaser’s acknowledgment of and agreement with these Terms and Conditions. American Electric Lighting reserves the right to change these Terms and Conditions of Sale without notice. * For shipments outside the United States, contact factory for applicable Terms and Conditions of Sale. TERMS AND CONDITIONS OF SALE For Shipments Within Canada* Effective August 25, 2008 TERMS: DROP SHIPMENTS: The words we, our and us shall refer to American Electric Lighting Canada (“AEL”), a division of Acuity Brands Lighting, Inc. and the words purchaser, you and your, shall refer to the person or entity purchasing products under this Agreement. AEL reserves the right to refuse to make direct shipments to points of destination outside of the regular or assigned selling and service area of the distributor. PAYMENT TERMS: AEL warrants all equipment to be free from defect in manufacturing, under normal and proper storage, installation, and use, for a period of one (1) year. In addition, AEL provides a six (6) year warranty on the factory installed electrical system (which consists of the ballast, ignitor, capacitor, lamp socket, terminal board, PEC receptacle, and wiring) inside AEL products. AEL’s guarantee liability extends only to the repair or replacement of the defective part, at AEL’s option, and no labor charges for correction of the defect by repair or replacement will be honored by AEL unless prior written authority has been granted by AEL’s Customer Service Department. THE FOREGOING GUARANTEE TERMS ARE EXCLUSIVE AND IN LIEU OF ALL OTHER GUARANTEES. AEL MAKES NO REPRESENTATIONS OR WARRANTIES EXCEPT AS EXPRESSLY SET FORTH IN THESE TERMS AND CONDITIONS, AND AEL EXPRESSLY DISCLAIMS ALL OTHER REPRESENTATIONS AND WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. NO DISTRIBUTOR OR SUPPLIER OF AEL HAS THE AUTHORITY TO MODIFY OR AMEND THIS GUARANTEE. Payment terms are 2% -10 or Net 30 days. 2%-10 days means that all invoices dated from the first to the 15th of the month are payable on the 25th of the same month. All invoices from the 15th to the 30th of the month are payable on the 10th of the following month. Alternatively, all invoices are due Net 30 days following invoice date. FREIGHT ALLOWANCE: Shipments are F.O.B. our plants, Lachine, Quebec, and St. Hyacinthe, Quebec, and our Canadian field warehouses. • Warehouse or factory orders must equal $3,000 U.S. or more for shipment to one consignee for one release to qualify for freight allowance. • All orders having a distributor price of less than $3,000 U.S. will be assessed freight and handling charges. • Special shipping requirements by the purchaser that cause additional shipping expenses above the normal shipping expenses will be charged to the purchaser. DELIVERY: AEL shall not be liable for any delay or default in delivering products for any reason beyond the reasonable control of AEL, including, but not limited to, armed conflict or economic dislocation resulting therefrom; embargoes; shortages of labor, raw materials, fuels, energy, production facilities or transportation; labor difficulties, civil disorders of any kind; action of civil or military authorities (including priorities and allocations); fires, floods, and accidents. No liability shall be incurred by AEL by reason of its not filling any order or portion thereof due to any of these or similar circumstances. TRANSPORTATION CLAIMS: Our equipment is tested for mechanical defects prior to shipping. Our packaging is regularly inspected by transportation authorities who assume responsibility for both apparent and concealed damages sustained by improper handling. Title passes to purchaser upon delivery by AEL to the carrier, and all claims for damages or shortages in transit shall be made by the purchaser to the delivering carrier. AEL will be glad to assist when called upon, provided notification is given in writing within 15 business days of receipt of shipment. PACKAGING: AEL reserves the right to alter quantities of any order so as to conform to standard packaging. PRICES: Prices are subject to change without notice. In the event of price increases, all orders on hand will be filled at the lower prices provided that such orders are released for shipping prior to the effective date of the price increase. If the orders are not released for shipment prior to the effective date of the price increase, the orders will be billed at the prices in effect at the time of the shipment. Special quoted orders which cannot be released for shipping prior to the price increase effective date may be subject to an increase in price. Minimum billing is $100 net excluding orders for replacement parts only. Orders for parts totaling less than $50 will automatically be billed $50 lump sum. Prices do not include lamps unless so specified. Prices exclude all taxes. RETURN MERCHANDISE: No merchandise may be returned without prior written authorization from AEL factories. Requests to return merchandise must be made with our agents for transmittal to the factory within four (4) months from date of shipment by us. All returns must be shipped prepaid to the location designated on the return authorization. Credit will be issued based on the original invoice price, or price in effect at time of return, whichever is lower, less a restocking charge of 25% (minimum) of the purchase price (to partially defray our cost of handling), less reconditioning and replacing costs if necessary, and less the freight expense of the original shipment. The reconditioning charge will be determined by the amount of repairs, refinishing or reconditioning required to restore the merchandise to a saleable condition. All non-stocking, special, custom-made, outdated, or modified versions of normal factory stocking items are not returnable. Authorization will not be granted when the value of all items to be returned is less than $100. Returns from any one order will be limited to not more than 10% of the total order value. GUARANTEE: LIMITATION OF LIABILITY: The foregoing guarantee provides the purchaser’s sole and exclusive remedy relating to AEL’s products. The total liability of AEL on any and all claims of any kind, whether in contract, warranty, tort (including negligence), strict liability or otherwise, arising out of or in connection with, or resulting from, AEL’s performance or breach of the foregoing limited warranty or from AEL’s sale, delivery, repair, or replacement of any products, or the furnishing of any services, shall in no event exceed the purchase price allocable to the specific product which gives rise to the claim, and any and all such liability shall terminate upon the expiration of the limited warranty set forth above. IN NO EVENT SHALL AEL BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR PUNITIVE DAMAGES, EVEN IF INFORMED OF THE POSSIBILITY OF SUCH DAMAGES, WHETHER AS THE RESULT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY, OR ANY OTHER THEORY. CANCELLATION CHARGES: Orders for stocking items may be cancelled prior to shipping without charge. All other orders may not be cancelled unless AEL is reimbursed for all work already performed and for all special materials purchased by AEL. If an order is cancelled after shipment or if delivery is refused at the delivery destination, all warehousing, delivery, and return costs will be charged to the purchaser. GENERAL: Possession of a price sheet does not entitle you to purchase any merchandise. Specifications are subject to change without notice. Consult factory for verification. The compliance of AEL’s product to individual project specifications and the approval for their use is not warranted by AEL. ACCEPTANCE: Acceptance of orders can be made only at AEL’s plants, distribution centers or field warehouses for warehouse orders on the basis of these terms and conditions of sale. Acceptance of orders is limited to the terms and conditions hereof. AEL hereby objects to any additional or different terms offered by the purchaser in its sales order or any other document of purchaser. Such additional or different terms shall not become a part of any order without the express written consent of AEL. ENTIRE AGREEMENT: Except as expressly agreed in writing signed by AEL, the terms and conditions stated above shall constitute the entire sales agreement between AEL and the purchaser. Any contrary or additional terms or conditions submitted by the purchaser (other than the description of the products being ordered and the requested quantities, shipping date, and shipping location contained in purchaser’s purchase order) shall be deemed to be of no force or effect and are hereby rejected. Purchaser’s submission of a purchase order shall indicate purchaser’s acknowledgment of and agreement with these Terms and Conditions. American Electric Lighting Canada reserves the right to change these Terms and Conditions of Sale without notice. *For shipments outside Canada, contact factory for applicable Terms and Conditions of Sale. Product Guide 245 Index ACP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .154 AMAC / SMAC / Arms for Concrete Poles . . . . . . . . . .224 AMAW / SMAW / Arms for Wood Poles . . . . . . . . . . . .222 ANSI Color Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186 ASA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122 AVL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134 AVL-BIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132 Accessories Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144 Floodlighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168 Photocontrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186 Roadway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118 Aluminum Mounting Brackets . . . . . . . . . . . . . . . . . . . .203 American Revolution Deluxe Series . . . . . . . . . . . . . . . .62 American Revolution Series 247 . . . . . . . . . . . . . . . . . . . .64 AmeriSport™ Series ASP . . . . . . . . . . . . . . . . . . . . . . . .164 Bainbridge Series 870 . . . . . . . . . . . . . . . . . . . . . . . . . . . .68 Ballast Matrices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148 Decorative . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 Floodlighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .173 Roadway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52 Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119 Branson . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84 Contempo Series 245 . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 Corvus™ CVM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Corvus™ CVL Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Cresthill Classic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .74 Cresthill Sphere . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76 Cresthill Centennial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78 Cresthill Glass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80 DP1704 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .176 DPN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183 DUX Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180 DX Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179 Decorative Poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90 Chadsworth Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90 New Albany Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 Statesboro Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .94 Waycross Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .96 Weatherproof Receptacles . . . . . . . . . . . . . . . . . . . . . .98 DuraStar® Series 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 DuraStar® Series 30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Dusk To Dawn Series DTD . . . . . . . . . . . . . . . . . . . . . . . .114 Energy Saver Series CES . . . . . . . . . . . . . . . . . . . . . . . .160 Georgian Series GRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 Heavy-Duty Wallpack 882 . . . . . . . . . . . . . . . . . . . . . . . . .46 InterState™ II 775 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38 LPS Roadway - SRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 LPS Roadway - SP2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 Lexington . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82 LuxMaster® Luminaire Series 53 . . . . . . . . . . . . . . . . . .136 LuxMaster® Luminaire Series 153 . . . . . . . . . . . . . . . . .138 LuxMaster® Classic Series LM . . . . . . . . . . . . . . . . . . . .142 LuxMaster® Classic Series LS . . . . . . . . . . . . . . . . . . . .140 Marietta Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70 Multi-Mount™ 285 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36 NEMA Head 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 NEMA Head Package Series 11 PKG . . . . . . . . . . . . . .110 D7790 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181 DBE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184 DD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182 DE Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178 DP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177 246 Product Guide PEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126 PES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124 Photocontrol Recommendation Chart . . . . . . . . . . . . . .186 Pole Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .202 For photometric information please visit our website: www.americanelectriclighting.com Index Pole Technical Data Florida Wind Rating . . . . . . . . . . . . . . . . . . . . . . . . . . .190 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . .191 Illustrated Samples . . . . . . . . . . . . . . . . . . . . . . . . . . .188 Wind Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189 Shorting and Open Caps . . . . . . . . . . . . . . . . . . . . . . . . .185 SignLite 875 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48 Steel Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . .204 Sportslighting Series SPF . . . . . . . . . . . . . . . . . . . . . . . .166 Sumter Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72 Quartz Flood Series 570 . . . . . . . . . . . . . . . . . . . . . . . . . .162 Technical Data Quartz Flood Series 474 . . . . . . . . . . . . . . . . . . . . . . . . . .163 Floodlighting Applications. . . . . . . . . . . . . . . . . . . . . .241 Floodlighting Calculations . . . . . . . . . . . . . . . . . . . . .242 Fuse Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234-239 HPS Replacement Starters . . . . . . . . . . . . . . . . . . . . .232 Lamp Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233 Luminaire Classification Systems . . . . . . . . . . . . . . .240 Roadway Lighting Calculations . . . . . . . . . . . . . . . . .243 Terms & Conditions . . . . . . . . . . . . . . . . . . . . . . . . . .244-245 Traditional Concrete Pole Arms . . . . . . . . . . . . . . . . . . .229 Traditional Wood Pole Arms . . . . . . . . . . . . . . . . . . . . . .228 TwistPack Series TWT . . . . . . . . . . . . . . . . . . . . . . . . . . . .88 RSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192 RTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193 RSAH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .194 RSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197 RTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .198 RTAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .216 RTF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .205 RTFDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206 RTSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .220 Roadway 115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Roadway 115 Cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Roadway 125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Roadway 125 Cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Roadway 315 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 Roadway 315 Cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 Roadway 325 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 Roadway 325 Cutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32 Roadway 327 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34 UltraFlood™ Series 75 . . . . . . . . . . . . . . . . . . . . . . . . . .156 UltraFlood™ Series 77 . . . . . . . . . . . . . . . . . . . . . . . . . . .158 Underpass 581/681 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 VLR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130 VMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128 Valiant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 SMAWL / Arms for Wall Mount . . . . . . . . . . . . . . . . . . .226 SPRTC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209 SPRTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .213 SSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195 SSAH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .196 SSF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .207 SSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199 STC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208 STS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200 STSH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201 Series 11 “L” Package . . . . . . . . . . . . . . . . . . . . . . . . . . .112 Series 165 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116 Product Guide 247 NOTES 248 Product Guide For photometric information please visit our website: www.americanelectriclighting.com NEW in Edition Three Edition Three of the American Electric Lighting Product Guide introduces several new products, shown below. Look for the “NEW” icon throughout the catalog to locate these new items. NEW CVM CVL ValiantTM ARD Page 10 Page 12 Page 60 Page 62 ASA PES PEM VMR VLR Page 122 Page 124 Page 126 Page 128 Page 130 AVL BIA ACP CES DP 1704 Page 132 Page 154 Page 160 Page 176 Sales Contact______________________________ AEL Customer #____________________________ Contact Email______________________________ Contact Phone _____________________________ To see available product literature, specification sheets, photometric reports and more, please visit us at: www.americanelectriclighting.com For Technical Support, contact us at: 1-800-754-0463 or AELtechsupport@americanelectriclighting.com American Electric Lighting Acuity Brands Lighting, Inc. 3825 Columbus Rd. S.W., Granville, OH 43023 Phone: 800-754-0463, Fax: 740-349-4490 www.americanelectriclighting.com ©2008 Acuity Brands Lighting, Inc. AEL-1315.17 4/08 Printed in USA