G3VM-61GR2

advertisement
G3VM-61GR2
MOS FET Relays
MOS FET Relays with 1.7-A switching
Designed for Switching Minute Signals
and Analog Signals.
• Continuous load current of 1.7 A.
Note: The actual product is marked differently from the
image shown here.
RoHS compliant
■ Application Examples
■ Terminal Arrangement/Internal Connections
4
• Semiconductor test equipment
3
Mold pin mark *
• Test & Measurement equipment
OMRON logo
• Communication equipment
932
Pin 1 mark
• Data loggers
1
Model name
LOT.No.
2
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from
a pin on the mold.
■ List of Models
Package type Contact form
SOP4
1a
(SPST-NO)
Load voltage
(peak value) *
Terminals
Surface-mounting Terminals
60 V
Model
G3VM-61GR2
G3VM-61GR2 (TR05)
Minimum package quantity
Number per tube Number per tape and reel
100
-
-
500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Pulse ON current
Connection temperature
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
∆IF/°C
VR
TJ
VOFF
IO
∆IO/°C
IOp
TJ
Rating
30
−0.3
5
125
60
1.7
−17
5
125
Unit
mA
mA/°C
V
°C
V
A
mA/°C
A
°C
VI-O
1500
Vrms
Ta
Tstg
-
−40 to +85
−55 to +125
260
°C
°C
°C
Measurement conditions
Ta ≥ 25°C
Ta ≥ 25°C
t = 100 ms, Duty = 1/10
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25°C)
Output
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.18
1.33
1.48
Reverse current
IR
10
Capacity between terminals
CT
70
Trigger LED forward current
IFT
0.6
3
Turn-OFF LED forward current
IFC
0.1
Maximum resistance with output ON
RON
0.08
0.13
Current leakage when the relay is open
ILEAK
1
10
Capacity between terminals
Coff
250
Capacity between I/O terminals
CI-O
0.8
Insulation resistance between I/O terminals
RI-O
1000
108
Turn-ON time
tON
0.7
3
Turn-OFF time
tOFF
0.1
0.5
1
Unit
V
µA
pF
mA
mA
Ω
nA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
Note: 2. Turn-ON and Turn-OFF Times
VR = 5 V
IF 1
4 RL
V = 0, f = 1 MHz
VDD
VOUT
IO = 100 mA
2
3
IOFF = 100 µA
IF = 5 mA, IO = 1.7 A, t < 1 s
VOFF = 60 V
V = 0, f = 1 MHz
IF
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
90%
VOUT
10%
IF = 5 mA, RL = 200 Ω,
t
ON
t OFF
VDD = 20 V (See note 2.)
G3VM-61GR2
MOS FET Relays
■ Recommended Operating Conditions
For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute
Maximum Ratings and Electrical Characteristics. Each item on this list is an independent condition, so it is not simultaneously satisfy
several conditions.
Item
Symbol
Minimum
Typical
Maximum
Unit
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Ambient operating temperature
VDD
IF
IO
Ta
5
-20
10
-
48
25
1.3
65
V
mA
A
°C
■ Engineering Data
LED forward current vs. Ambient
temperature
IO - Ta
(Maximum value)
50
40
30
20
LED forward current vs. LED forward
voltage
(Maximum value)
2
LED forward current IF (mA)
Continuous load current IO (A)
LED forward current IF (mA)
IF - Ta
Continuous load current vs. Ambient
temperature
1.8
1.6
1.4
1.2
1
0.8
IF - VF
(Average value)
1.2
1.6
100
Ta = 25 °C
10
1
0.6
0.1
10
0.4
0.2
0
-40
-20
0
20
40
60
80
0
-40
100
-20
0
20
Ambient temperature Ta (°C)
Continuous load current vs. On-state
voltage
0.5
0
-0.5
0.01
0.6
100
0.8
1
RON - Ta
IO = 1.7 A
IF = 5 mA
t<1s
0.1
-1
1.8
Trigger LED forward current vs.
Ambient temperature
IFT - Ta
(Average value)
0.2
1.4
LED forward voltage VF (V)
Trigger LED forward current IFT (mA)
Continuous load current IO (A)
1
80
On-state resistance vs. Ambient
temperature
(Average value)
Ta = 25 °C
IF = 5 mA
1.5
60
Ambient temperature Ta (°C)
On-state resistance RON (Ω)
IO - VON
2
40
(Average value)
2
IO = 100 mA
1.5
1
0.5
-1.5
-2
-0.1
0
0.1
0
-40
0.2
-20
0
20
On-state voltage VON (V)
Turn ON, Turn OFF time vs. LED
forward current
1
tOFF
Ta = 25 °C
VDD = 20 V
RL = 200 Ω
1
tON, tOFF - Ta
(Average value)
tON
0.01
80
0
-40
100
Turn ON, Turn OFF time vs. Ambient
temperature
10
0.1
60
-20
0
20
Ambient temperature Ta (°C)
Turn ON, Turn OFF time tON, tOFF (ms)
Turn ON, Turn OFF time tON, tOFF (ms)
tON, tOFF - IF
40
1
tON
60
80
100
Current leakage vs. Ambient
temperature
ILEAK - Ta
(Average value)
10
40
Ambient temperature Ta (°C)
Current leakage ILEAK (nA)
-0.2
(Average value)
100
VOFF = 60 V
10
1
0.1
tOFF
VDD = 20 V
0.1
RL = 200 Ω
IF = 5 mA
10
100
0.01
-40
-20
LED forward current IF (mA)
0
20
40
60
80
100
Ambient temperature Ta (°C)
0.01
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SOP4 type
■ Appearance
SOP (Small Outline Package)
SOP4
Mold pin mark *
OMRON logo
Pin 1 mark
932
Model name
LOT.No.
Note: The actual product is marked differently from the image shown here.
* The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.
■ Dimensions
(Unit: mm)
Surface-mounting Terminals
Actual Mounting Pad
Dimensions
Weight: 0.1 g
4.4±0.25
3.9±0.2
(Recommended Value, TOP VIEW)
2.1 max.
6 to 6.3
0.15
0.4±0.1
0.1±0.1
1.2
0.6±0.3
7.0±0.4
2.54±0.25
Note: The actual product is marked differently from the image shown here.
0.8
2.54
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K281-E1-01
1015(1015)(O)
Download