G3VM-61GR2 MOS FET Relays MOS FET Relays with 1.7-A switching Designed for Switching Minute Signals and Analog Signals. • Continuous load current of 1.7 A. Note: The actual product is marked differently from the image shown here. RoHS compliant ■ Application Examples ■ Terminal Arrangement/Internal Connections 4 • Semiconductor test equipment 3 Mold pin mark * • Test & Measurement equipment OMRON logo • Communication equipment 932 Pin 1 mark • Data loggers 1 Model name LOT.No. 2 Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. ■ List of Models Package type Contact form SOP4 1a (SPST-NO) Load voltage (peak value) * Terminals Surface-mounting Terminals 60 V Model G3VM-61GR2 G3VM-61GR2 (TR05) Minimum package quantity Number per tube Number per tape and reel 100 - - 500 * The AC peak and DC value are given for the load voltage. ■ Absolute Maximum Ratings (Ta = 25°C) Output Input Item LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Continuous load current (AC peak/DC) ON current reduction rate Pulse ON current Connection temperature Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Symbol IF ∆IF/°C VR TJ VOFF IO ∆IO/°C IOp TJ Rating 30 −0.3 5 125 60 1.7 −17 5 125 Unit mA mA/°C V °C V A mA/°C A °C VI-O 1500 Vrms Ta Tstg - −40 to +85 −55 to +125 260 °C °C °C Measurement conditions Ta ≥ 25°C Ta ≥ 25°C t = 100 ms, Duty = 1/10 AC for 1 min With no icing or condensation With no icing or condensation 10 s Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. ■ Electrical Characteristics (Ta = 25°C) Output Input Item Symbol Minimum Typical Maximum LED forward voltage VF 1.18 1.33 1.48 Reverse current IR 10 Capacity between terminals CT 70 Trigger LED forward current IFT 0.6 3 Turn-OFF LED forward current IFC 0.1 Maximum resistance with output ON RON 0.08 0.13 Current leakage when the relay is open ILEAK 1 10 Capacity between terminals Coff 250 Capacity between I/O terminals CI-O 0.8 Insulation resistance between I/O terminals RI-O 1000 108 Turn-ON time tON 0.7 3 Turn-OFF time tOFF 0.1 0.5 1 Unit V µA pF mA mA Ω nA pF pF MΩ ms ms Measurement conditions IF = 10 mA Note: 2. Turn-ON and Turn-OFF Times VR = 5 V IF 1 4 RL V = 0, f = 1 MHz VDD VOUT IO = 100 mA 2 3 IOFF = 100 µA IF = 5 mA, IO = 1.7 A, t < 1 s VOFF = 60 V V = 0, f = 1 MHz IF f = 1 MHz, VS = 0 V VI-O = 500 VDC, ROH ≤ 60 % 90% VOUT 10% IF = 5 mA, RL = 200 Ω, t ON t OFF VDD = 20 V (See note 2.) G3VM-61GR2 MOS FET Relays ■ Recommended Operating Conditions For usage with high reliability, Recommended Operation Conditions is a measure that takes into account the derating of Absolute Maximum Ratings and Electrical Characteristics. Each item on this list is an independent condition, so it is not simultaneously satisfy several conditions. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) Operating LED forward current Continuous load current (AC peak/DC) Ambient operating temperature VDD IF IO Ta 5 -20 10 - 48 25 1.3 65 V mA A °C ■ Engineering Data LED forward current vs. Ambient temperature IO - Ta (Maximum value) 50 40 30 20 LED forward current vs. LED forward voltage (Maximum value) 2 LED forward current IF (mA) Continuous load current IO (A) LED forward current IF (mA) IF - Ta Continuous load current vs. Ambient temperature 1.8 1.6 1.4 1.2 1 0.8 IF - VF (Average value) 1.2 1.6 100 Ta = 25 °C 10 1 0.6 0.1 10 0.4 0.2 0 -40 -20 0 20 40 60 80 0 -40 100 -20 0 20 Ambient temperature Ta (°C) Continuous load current vs. On-state voltage 0.5 0 -0.5 0.01 0.6 100 0.8 1 RON - Ta IO = 1.7 A IF = 5 mA t<1s 0.1 -1 1.8 Trigger LED forward current vs. Ambient temperature IFT - Ta (Average value) 0.2 1.4 LED forward voltage VF (V) Trigger LED forward current IFT (mA) Continuous load current IO (A) 1 80 On-state resistance vs. Ambient temperature (Average value) Ta = 25 °C IF = 5 mA 1.5 60 Ambient temperature Ta (°C) On-state resistance RON (Ω) IO - VON 2 40 (Average value) 2 IO = 100 mA 1.5 1 0.5 -1.5 -2 -0.1 0 0.1 0 -40 0.2 -20 0 20 On-state voltage VON (V) Turn ON, Turn OFF time vs. LED forward current 1 tOFF Ta = 25 °C VDD = 20 V RL = 200 Ω 1 tON, tOFF - Ta (Average value) tON 0.01 80 0 -40 100 Turn ON, Turn OFF time vs. Ambient temperature 10 0.1 60 -20 0 20 Ambient temperature Ta (°C) Turn ON, Turn OFF time tON, tOFF (ms) Turn ON, Turn OFF time tON, tOFF (ms) tON, tOFF - IF 40 1 tON 60 80 100 Current leakage vs. Ambient temperature ILEAK - Ta (Average value) 10 40 Ambient temperature Ta (°C) Current leakage ILEAK (nA) -0.2 (Average value) 100 VOFF = 60 V 10 1 0.1 tOFF VDD = 20 V 0.1 RL = 200 Ω IF = 5 mA 10 100 0.01 -40 -20 LED forward current IF (mA) 0 20 40 60 80 100 Ambient temperature Ta (°C) 0.01 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions SOP4 type ■ Appearance SOP (Small Outline Package) SOP4 Mold pin mark * OMRON logo Pin 1 mark 932 Model name LOT.No. Note: The actual product is marked differently from the image shown here. * The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold. ■ Dimensions (Unit: mm) Surface-mounting Terminals Actual Mounting Pad Dimensions Weight: 0.1 g 4.4±0.25 3.9±0.2 (Recommended Value, TOP VIEW) 2.1 max. 6 to 6.3 0.15 0.4±0.1 0.1±0.1 1.2 0.6±0.3 7.0±0.4 2.54±0.25 Note: The actual product is marked differently from the image shown here. 0.8 2.54 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K281-E1-01 1015(1015)(O)