G3VM-41LR11 MOS FET Relays World’s Smallest * SSOP Package MOS FET Relays (COFF (typical): 0.7 pF, RON (typical): 7 Ω) with Low Output Capacitance and ON Resistance (C × R = 5 pF • Ω) in a 40-V Load Voltage Model. • ON resistance of 7 Ω (typical) suppresses output signal attenuation. * As of March 2011 Survey by OMRON Note: The actual product is marked differently from the image shown here. RoHS compliant ■ Application Examples ■ Terminal Arrangement/Internal Connections • Semiconductor test equipment 416 • Test & Measurement equipment Model name OMRON mark • Communication equipment LOT.No. 612 • Data loggers Note: The actual product is marked differently from the image shown here. ■ List of Models Package type Contact form Load voltage (peak value) * Terminals Model Minimum package quantity Number per tape and reel G3VM-41LR11 SSOP4 1a (SPST-NO) Surface-mounting Terminals 40 V G3VM-41LR11 (TR05) G3VM-41LR11 (TR) 500 1,500 Note: Ask your OMRON representative for orders under 1500 pcs or 500 pcs. We can supply products with the tape already cut. Tape-cut SSOPs are packaged without humidity resistance. Use manual soldering to mount them. Refer to common precautions. * The AC peak and DC value are given for the load voltage. ■ Absolute Maximum Ratings (Ta = 25 °C) Output Input Item LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Continuous load current (AC peak/DC) ON current reduction rate Connection temperature Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Symbol IF ∆IF/°C VR TJ VOFF IO ∆IO/°C TJ Rating 30 −0.3 5 125 40 140 −1.4 125 Unit mA mA/°C V °C V mA mA/°C °C VI-O 1500 Vrms Ta Tstg - −20 to +85 −40 to +125 260 °C °C °C Measurement conditions Ta ≥ 25 °C Ta ≥ 25 °C AC for 1 min With no icing or condensation With no icing or condensation 10 s Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. ■ Electrical Characteristics (Ta = 25 °C) Output Input Item Symbol Minimum Typical Maximum LED forward voltage VF 1.15 1.30 1.45 Reverse current IR 10 Capacity between terminals CT 70 Trigger LED forward current IFT 3 Maximum resistance with output ON RON 7 10 Current leakage when the relay is open ILEAK 10 200 Capacity between terminals COFF 0.7 1.3 Capacity between I/O terminals CI-O 0.3 Insulation resistance between I/O terminals RI-O 1000 Turn-ON time tON 0.2 Turn-OFF time tOFF 0.2 1 Unit V µA pF mA Ω pA pF pF MΩ ms ms Measurement conditions Note: 2. Turn-ON and Turn-OFF Times IF = 5 mA IF 1 VR = 5 V 4 RL VDD V = 0, f = 1 MHz VOUT 2 3 IO = 100 mA IF = 5 mA, IO = 140 mA, t < 1 s VOFF = 35 V, Ta = 25 °C V = 0, f = 100 MHz, t < 1 s IF f = 1 MHz, VS = 0 V VI-O = 500 VDC, ROH ≤ 60 % 90% VOUT 10% IF = 5 mA, RL = 200 Ω, t ON t OFF VDD = 10 V (See note 2.) G3VM-41LR11 MOS FET Relays ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Load voltage (AC peak/DC) VDD - - 32 Unit V Operating LED forward current IF - - 20 mA Continuous load current (AC peak/DC) IO - - 140 mA Ambient operating temperature Ta 25 - 60 °C ■ Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature 50 40 30 20 IF - VF LED forward current IF (mA) IO - Ta Continuous load current IO (mA) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 200 180 160 140 120 100 80 Ta = 25 °C 50 30 10 5 60 3 40 10 100 20 -20 0 20 40 60 80 100 0 -20 120 0 20 40 Ambient temperature Ta (°C) Continuous load current vs. On-state voltage Ta = 25 °C IF = 5 mA 100 50 0 -50 -0.5 0 IO = 140 mA IF = 5 mA t<1s 12 10 8 6 0.5 1.0 0 -20 1.5 0 20 On-state voltage VON (V) Turn ON, Turn OFF time vs. LED forward current Turn ON, Turn OFF time tON, tOFF (µs) 100 50 30 tON 5 3 1 3 5 10 30 50 1.4 1.5 1.6 LED forward voltage VF (V) 60 80 5 IO = 140 mA 4 3 2 1 0 -20 100 0 20 40 80 100 Current leakage vs. Ambient temperature ILEAK - Ta VDD = 10 V, RL = 200 Ω IF = 5 mA tOFF 100 60 Ambient temperature Ta (°C) tON, tOFF - Ta tOFF 10 40 Turn ON, Turn OFF time vs. Ambient temperature Ta = 25 °C VDD = 10 V, RL = 200 Ω 200 1.3 Ambient temperature Ta (°C) tON, tOFF - IF 1 1.2 IFT - Ta 14 2 -1.0 1.1 Trigger LED forward current vs. Ambient temperature 4 -100 -200 -1.5 1 1 120 Trigger LED forward current IFT (mA) On-state resistance RON (Ω) Continuous load current IO (mA) 100 RON - Ta -150 Turn ON, Turn OFF time tON, tOFF (µs) 80 On-state resistance vs. Ambient temperature IO - VON 200 150 60 Ambient temperature Ta (°C) Current leakage ILEAK (pA) 0 50 30 tON 10 1000 VOFF = 35 V 100 10 5 3 1 -20 1 0 LED forward current IF (mA) 20 40 60 80 100 Ambient temperature Ta (°C) -20 0 20 40 60 80 100 Ambient temperature Ta (°C) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions SSOP4 type ■ Appearance SSOP (Shrink Small Outline Package) SSOP4 416 Model name OMRON mark 612 LOT.No. Note: The actual product is marked differently from the image shown here. ■ Dimensions 416 (Unit: mm) Surface-mounting Terminals 612 Weight: 0.03 g 4.2 Actual Mounting Pad Dimensions (Recommended Value, TOP VIEW) 1.9 1.4 dia. 3.65 0.15 (0.3) 1.27 2.04 1.8 0.95 3.73 0.2 3.8 0.8 1.27 (0.46) Unless otherwise specified, the dimensional tolerance is ± 0.1 mm. Note: The actual product is marked differently from the image shown here. • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K206-E1-01 0412(0412)(O)