G3VM-41LR11

advertisement
G3VM-41LR11
MOS FET Relays
World’s Smallest * SSOP Package MOS
FET Relays (COFF (typical): 0.7 pF, RON
(typical): 7 Ω) with Low Output
Capacitance and ON Resistance (C × R =
5 pF • Ω) in a 40-V Load Voltage Model.
• ON resistance of 7 Ω (typical) suppresses output signal attenuation.
* As of March 2011 Survey by OMRON
Note: The actual product is marked differently from the
image shown here.
RoHS compliant
■ Application Examples
■ Terminal Arrangement/Internal Connections
• Semiconductor test equipment
416
• Test & Measurement equipment
Model name
OMRON mark
• Communication equipment
LOT.No.
612
• Data loggers
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type
Contact form
Load voltage
(peak value) *
Terminals
Model
Minimum package quantity
Number per tape and reel
G3VM-41LR11
SSOP4
1a
(SPST-NO)
Surface-mounting Terminals
40 V
G3VM-41LR11 (TR05)
G3VM-41LR11 (TR)
500
1,500
Note: Ask your OMRON representative for orders under 1500 pcs or 500 pcs. We can supply products with the tape already cut.
Tape-cut SSOPs are packaged without humidity resistance. Use manual soldering to mount them.
Refer to common precautions.
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25 °C)
Output
Input
Item
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Connection temperature
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
∆IF/°C
VR
TJ
VOFF
IO
∆IO/°C
TJ
Rating
30
−0.3
5
125
40
140
−1.4
125
Unit
mA
mA/°C
V
°C
V
mA
mA/°C
°C
VI-O
1500
Vrms
Ta
Tstg
-
−20 to +85
−40 to +125
260
°C
°C
°C
Measurement conditions
Ta ≥ 25 °C
Ta ≥ 25 °C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25 °C)
Output
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.15
1.30
1.45
Reverse current
IR
10
Capacity between terminals
CT
70
Trigger LED forward current
IFT
3
Maximum resistance with output ON
RON
7
10
Current leakage when the relay is open
ILEAK
10
200
Capacity between terminals COFF
0.7
1.3
Capacity between I/O terminals
CI-O
0.3
Insulation resistance between I/O terminals
RI-O
1000
Turn-ON time
tON
0.2
Turn-OFF time
tOFF
0.2
1
Unit
V
µA
pF
mA
Ω
pA
pF
pF
MΩ
ms
ms
Measurement conditions
Note: 2. Turn-ON and Turn-OFF Times
IF = 5 mA
IF 1
VR = 5 V
4 RL
VDD
V = 0, f = 1 MHz
VOUT
2
3
IO = 100 mA
IF = 5 mA, IO = 140 mA, t < 1 s
VOFF = 35 V, Ta = 25 °C
V = 0, f = 100 MHz, t < 1 s
IF
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
90%
VOUT
10%
IF = 5 mA, RL = 200 Ω,
t ON
t OFF
VDD = 10 V (See note 2.)
G3VM-41LR11
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Load voltage (AC peak/DC)
VDD
-
-
32
Unit
V
Operating LED forward current
IF
-
-
20
mA
Continuous load current (AC peak/DC)
IO
-
-
140
mA
Ambient operating temperature
Ta
25
-
60
°C
■ Engineering Data
LED forward current vs. Ambient
temperature
Continuous load current vs. Ambient
temperature
50
40
30
20
IF - VF
LED forward current IF (mA)
IO - Ta
Continuous load current IO (mA)
LED forward current IF (mA)
IF - Ta
LED forward current vs. LED forward
voltage
200
180
160
140
120
100
80
Ta = 25 °C
50
30
10
5
60
3
40
10
100
20
-20
0
20
40
60
80
100
0
-20
120
0
20
40
Ambient temperature Ta (°C)
Continuous load current vs. On-state
voltage
Ta = 25 °C
IF = 5 mA
100
50
0
-50
-0.5
0
IO = 140 mA
IF = 5 mA
t<1s
12
10
8
6
0.5
1.0
0
-20
1.5
0
20
On-state voltage VON (V)
Turn ON, Turn OFF time vs. LED
forward current
Turn ON, Turn OFF time tON, tOFF (µs)
100
50
30
tON
5
3
1
3
5
10
30
50
1.4
1.5
1.6
LED forward voltage VF (V)
60
80
5
IO = 140 mA
4
3
2
1
0
-20
100
0
20
40
80
100
Current leakage vs. Ambient
temperature
ILEAK - Ta
VDD = 10 V, RL = 200 Ω
IF = 5 mA
tOFF
100
60
Ambient temperature Ta (°C)
tON, tOFF - Ta
tOFF
10
40
Turn ON, Turn OFF time vs. Ambient
temperature
Ta = 25 °C
VDD = 10 V, RL = 200 Ω
200
1.3
Ambient temperature Ta (°C)
tON, tOFF - IF
1
1.2
IFT - Ta
14
2
-1.0
1.1
Trigger LED forward current vs.
Ambient temperature
4
-100
-200
-1.5
1
1
120
Trigger LED forward current IFT (mA)
On-state resistance RON (Ω)
Continuous load current IO (mA)
100
RON - Ta
-150
Turn ON, Turn OFF time tON, tOFF (µs)
80
On-state resistance vs. Ambient
temperature
IO - VON
200
150
60
Ambient temperature Ta (°C)
Current leakage ILEAK (pA)
0
50
30
tON
10
1000
VOFF = 35 V
100
10
5
3
1
-20
1
0
LED forward current IF (mA)
20
40
60
80
100
Ambient temperature Ta (°C)
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SSOP4 type
■ Appearance
SSOP (Shrink Small Outline Package)
SSOP4
416
Model name
OMRON mark
612
LOT.No.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
416
(Unit: mm)
Surface-mounting Terminals
612
Weight: 0.03 g
4.2
Actual Mounting Pad
Dimensions
(Recommended Value, TOP VIEW)
1.9
1.4 dia.
3.65
0.15
(0.3)
1.27
2.04
1.8
0.95 3.73
0.2
3.8
0.8
1.27
(0.46)
Unless otherwise specified, the
dimensional tolerance is ± 0.1 mm.
Note: The actual product is marked differently from the image shown here.
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K206-E1-01
0412(0412)(O)