G3VM-61BR/ER

advertisement
G3VM-61BR/ER
MOS FET Relays
New Analog-switching MOS FET Relays
Featuring a High Capacity of 2.5 A.
• Switches minute analog signals.
• Low ON-resistance of 0.1 Ω max.
• Continuous load current of 2.5 A.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal Connections
• Test & Measurement equipment
6
4
• Security equipment
OMRON logo
932
Pin 1 mark
2
1
Model
name
LOT.NO.
3
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type Contact form
Load voltage
(peak value) *
Terminals
PCB Terminals
1a
(SPST-NO)
DIP6
Model
Minimum package quantity
Number per tube Number per tape and reel
G3VM-61BR
60 V
Surface-mounting Terminals
G3VM-61ER
G3VM-61ER(TR)
50
-
-
1,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Connection temperature
Dielectric strength between I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
∆IF/°C
VR
TJ
VOFF
IO
∆IO/°C
TJ
VI-O
Ta
Tstg
-
Rating
30
−0.3
5
125
60
2500
−22
125
2500
−20 to +85
−40 to +125
260
Unit
mA
mA/°C
V
°C
V
mA
mA/°C
°C
Vrms
°C
°C
°C
Measurement conditions
Ta ≥ 25°C
Ta ≥ 40°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■ Electrical Characteristics (Ta = 25°C)
Item
Symbol Minimum Typical Maximum
Unit
Measurement conditions
VF
IR
1.18
-
1.33
-
1.48
10
V
µA
IF = 10 mA
VR = 5 V
Capacity between terminals
Trigger LED forward current
CT
IFT
-
70
1.0
3
pF
mA
V = 0, f = 1 MHz
IO = 1 A
Maximum resistance with output ON
Current leakage when the relay is open
ILEAK
-
0.065
1.0
0.1
10
Ω
nA
IF = 10 mA, IO = 2 A, t = 10 ms
VOFF = 60 V
Capacity between terminals
Capacity between I/O terminals
COFF
CI-O
-
400
0.8
600
-
pF
pF
V = 0, f = 1 MHz
f = 1 MHz, VS = 0 V
Insulation resistance between I/O terminals
Turn-ON time
RI-O
tON
1000
-
1.0
1.5
MΩ
ms
Turn-OFF time
tOFF
-
0.2
0.4
ms
Output
Input
LED forward voltage
Reverse current
1
Note: 2. Turn-ON and Turn-OFF Times
IF 1
6
2
4
RL
VDD
VOUT
IF
VI-O = 500 VDC, ROH ≤ 60%
IF = 10 mA, RL = 200 Ω,
VDD = 20 V(See note 2.)
VOUT
10%
t ON
90%
t OFF
G3VM-61BR/ER
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Unit
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Ambient operating temperature
VDD
IF
IO
Ta
10
25
-
48
20
2500
60
V
mA
mA
°C
■ Engineering Data
LED forward current vs. Ambient
temperature
Continuous load current vs. Ambient
temperature
IO - Ta
40
30
20
IF - V F
4
LED forward current IF (mA)
50
Continuous load current IO (A)
LED forward current IF (mA)
IF - Ta
LED forward current vs. LED forward
voltage
3
2
Ta = 25°C
30
10
5
3
0.5
10
0.3
0
-20
0
20
40
60
80
100
0
-20
120
0
20
40
Ambient temperature Ta (°C)
Continuous load current vs. On-state
voltage
80
100
On-state resistance vs. Ambient
temperature
1
0
-1
IO = 2A
IF = 10mA
150
100
50
100
0
-20
150
0
20
On-state voltage VON (mV)
Turn ON, Turn OFF time vs. LED
forward current
40
60
80
tON, tOFF - IF
Turn ON, Turn OFF time tON, tOFF (µs)
Ta = 25°C
VDD = 20V, RL= 200Ω
3000
1000
t ON
300
t OFF
100
VDD = 20V
RL= 200Ω, IF = 5mA
3000
t ON
1000
t OFF
300
10
2
1
0
20
30
20
40
60
80
100
Ambient temperature Ta (°C)
Current leakage vs. Ambient
temperature
1000
VOFF = 60V
100
10
100
30
30
0
3
ILEAK - Ta
30000
10000
1.8
IO = 2A
tON, tOFF - Ta
10000
1.6
4
0
-20
100
Turn ON, Turn OFF time vs. Ambient
temperature
30000
1.4
5
Ambient temperature Ta (°C)
Current leakage ILEAK (nA)
0
1.2
IFT - Ta
200
50
-50
1
Trigger LED forward current vs.
Ambient temperature
-2
-100
0.8
LED forward voltage VF (V)
Trigger LED forward current IFT (mA)
On-state resistance RON (mΩ)
Ta = 25°C
IF = 10mA
-3
-150
0.1
0.6
120
RON - Ta
3
2
60
Ambient temperature Ta (°C)
IO - VON
Continuous load current IO (A)
50
1
1
Turn ON, Turn OFF time tON, tOFF (µs)
100
-20
0
LED forward current IF (mA)
20
40
60
80
100
Ambient temperature Ta (°C)
1
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
DIP6 (special) type
■ Appearance
DIP (Dual Inline Package)
DIP6 (special)
OMRON logo
Model name
932
Pin 1 mark
LOT.NO.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
(Unit:mm)
PCB Terminals
Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW)
Weight: 0.4 g
Weight: 0.4 g
Five, 0.8-dia. holes
2.54
(0.61)
2.54
7.12±0.25
7.12±0.25
6.4±0.25
(0.61)
(1.52)
(1.52)
6.4±0.25
Actual Mounting Pad Dimensions
7.62±0.25
0.8±0.25
7.62±0.25
(Recommended Value, TOP VIEW)
+0.15
3.65 −0.25
0.25+0.1
−0.05
2.5 min.
1.2±0.15
0.5±0.1
2.54±0.25
7.85 to 8.80
4.0 +0.25
−0.2
3.65 +0.15
−0.25
1.0 min.
1.2±0.15
2.54±0.25
Note: The actual product is marked differently from the
image shown here.
1.0 min.
10.0 max.
2.54
2.54
8.3 to 8.8
1.3
1.5
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K175-E1-01
0412(0412)(O)
Download