G3VM-61BR/ER MOS FET Relays New Analog-switching MOS FET Relays Featuring a High Capacity of 2.5 A. • Switches minute analog signals. • Low ON-resistance of 0.1 Ω max. • Continuous load current of 2.5 A. RoHS compliant Note: The actual product is marked differently from the image shown here. ■ Application Examples ■ Terminal Arrangement/Internal Connections • Test & Measurement equipment 6 4 • Security equipment OMRON logo 932 Pin 1 mark 2 1 Model name LOT.NO. 3 Note: The actual product is marked differently from the image shown here. ■ List of Models Package type Contact form Load voltage (peak value) * Terminals PCB Terminals 1a (SPST-NO) DIP6 Model Minimum package quantity Number per tube Number per tape and reel G3VM-61BR 60 V Surface-mounting Terminals G3VM-61ER G3VM-61ER(TR) 50 - - 1,500 * The AC peak and DC value are given for the load voltage. ■ Absolute Maximum Ratings (Ta = 25°C) Output Input Item LED forward current LED forward current reduction rate LED reverse voltage Connection temperature Load voltage (AC peak/DC) Continuous load current (AC peak/DC) ON current reduction rate Connection temperature Dielectric strength between I/O (See note 1.) Ambient operating temperature Ambient storage temperature Soldering temperature Symbol IF ∆IF/°C VR TJ VOFF IO ∆IO/°C TJ VI-O Ta Tstg - Rating 30 −0.3 5 125 60 2500 −22 125 2500 −20 to +85 −40 to +125 260 Unit mA mA/°C V °C V mA mA/°C °C Vrms °C °C °C Measurement conditions Ta ≥ 25°C Ta ≥ 40°C AC for 1 min With no icing or condensation With no icing or condensation 10 s Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. ■ Electrical Characteristics (Ta = 25°C) Item Symbol Minimum Typical Maximum Unit Measurement conditions VF IR 1.18 - 1.33 - 1.48 10 V µA IF = 10 mA VR = 5 V Capacity between terminals Trigger LED forward current CT IFT - 70 1.0 3 pF mA V = 0, f = 1 MHz IO = 1 A Maximum resistance with output ON Current leakage when the relay is open ILEAK - 0.065 1.0 0.1 10 Ω nA IF = 10 mA, IO = 2 A, t = 10 ms VOFF = 60 V Capacity between terminals Capacity between I/O terminals COFF CI-O - 400 0.8 600 - pF pF V = 0, f = 1 MHz f = 1 MHz, VS = 0 V Insulation resistance between I/O terminals Turn-ON time RI-O tON 1000 - 1.0 1.5 MΩ ms Turn-OFF time tOFF - 0.2 0.4 ms Output Input LED forward voltage Reverse current 1 Note: 2. Turn-ON and Turn-OFF Times IF 1 6 2 4 RL VDD VOUT IF VI-O = 500 VDC, ROH ≤ 60% IF = 10 mA, RL = 200 Ω, VDD = 20 V(See note 2.) VOUT 10% t ON 90% t OFF G3VM-61BR/ER MOS FET Relays ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Maximum Unit Load voltage (AC peak/DC) Operating LED forward current Continuous load current (AC peak/DC) Ambient operating temperature VDD IF IO Ta 10 25 - 48 20 2500 60 V mA mA °C ■ Engineering Data LED forward current vs. Ambient temperature Continuous load current vs. Ambient temperature IO - Ta 40 30 20 IF - V F 4 LED forward current IF (mA) 50 Continuous load current IO (A) LED forward current IF (mA) IF - Ta LED forward current vs. LED forward voltage 3 2 Ta = 25°C 30 10 5 3 0.5 10 0.3 0 -20 0 20 40 60 80 100 0 -20 120 0 20 40 Ambient temperature Ta (°C) Continuous load current vs. On-state voltage 80 100 On-state resistance vs. Ambient temperature 1 0 -1 IO = 2A IF = 10mA 150 100 50 100 0 -20 150 0 20 On-state voltage VON (mV) Turn ON, Turn OFF time vs. LED forward current 40 60 80 tON, tOFF - IF Turn ON, Turn OFF time tON, tOFF (µs) Ta = 25°C VDD = 20V, RL= 200Ω 3000 1000 t ON 300 t OFF 100 VDD = 20V RL= 200Ω, IF = 5mA 3000 t ON 1000 t OFF 300 10 2 1 0 20 30 20 40 60 80 100 Ambient temperature Ta (°C) Current leakage vs. Ambient temperature 1000 VOFF = 60V 100 10 100 30 30 0 3 ILEAK - Ta 30000 10000 1.8 IO = 2A tON, tOFF - Ta 10000 1.6 4 0 -20 100 Turn ON, Turn OFF time vs. Ambient temperature 30000 1.4 5 Ambient temperature Ta (°C) Current leakage ILEAK (nA) 0 1.2 IFT - Ta 200 50 -50 1 Trigger LED forward current vs. Ambient temperature -2 -100 0.8 LED forward voltage VF (V) Trigger LED forward current IFT (mA) On-state resistance RON (mΩ) Ta = 25°C IF = 10mA -3 -150 0.1 0.6 120 RON - Ta 3 2 60 Ambient temperature Ta (°C) IO - VON Continuous load current IO (A) 50 1 1 Turn ON, Turn OFF time tON, tOFF (µs) 100 -20 0 LED forward current IF (mA) 20 40 60 80 100 Ambient temperature Ta (°C) 1 -20 0 20 40 60 80 100 Ambient temperature Ta (°C) ■ Safety Precautions • Refer to "Common Precautions" for all G3VM models. 2 Appearance/Dimensions DIP6 (special) type ■ Appearance DIP (Dual Inline Package) DIP6 (special) OMRON logo Model name 932 Pin 1 mark LOT.NO. Note: The actual product is marked differently from the image shown here. ■ Dimensions (Unit:mm) PCB Terminals Surface-mounting Terminals PCB Dimensions (BOTTOM VIEW) Weight: 0.4 g Weight: 0.4 g Five, 0.8-dia. holes 2.54 (0.61) 2.54 7.12±0.25 7.12±0.25 6.4±0.25 (0.61) (1.52) (1.52) 6.4±0.25 Actual Mounting Pad Dimensions 7.62±0.25 0.8±0.25 7.62±0.25 (Recommended Value, TOP VIEW) +0.15 3.65 −0.25 0.25+0.1 −0.05 2.5 min. 1.2±0.15 0.5±0.1 2.54±0.25 7.85 to 8.80 4.0 +0.25 −0.2 3.65 +0.15 −0.25 1.0 min. 1.2±0.15 2.54±0.25 Note: The actual product is marked differently from the image shown here. 1.0 min. 10.0 max. 2.54 2.54 8.3 to 8.8 1.3 1.5 • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation ELECTRONIC AND MECHANICAL COMPONENTS COMPANY Contact: www.omron.com/ecb Cat. No. K175-E1-01 0412(0412)(O)