Electronics HID-PrimaVision CDM Electronics HID-PrimaVision mCDM Product Description • Miniature, one-piece electronic ballast for Philips miniMaster CDMTm 20W ceramic metal halide lamps • Developed together with the miniMaster CDM-Tm lamps for optimum system performance Wiring diagram HID-PV C 35/70/150 EH-S 2X35 BALLAST ~ ~ U mains Features and Benefits: Choice of versions: • standard version (/S) with full polycarbonate/ABS housing • with 2x strain relief (/I) for stand–alone applications • PCB version (/P) for integration in luminaire • Advantages in luminaire miniaturization and cable ratings due to low-rated ignition voltage (<1.5 kV) compared with higher-wattage CDM lamps (<5 kV) • Microprocessor-controlled operation plus state-of-the-art software based on Philips' expertise in compact HID lamp operation 4kV Connection wiring is greatly simplified by the use of cage-clamp contacts with push buttons. Wire cross-section: On the mains side: On the lamp side: 0.75…2.5 mm2 0.75…2.5 mm2 Strip length: 8 - 10 mm HID-PV m 1X020/S CDM LPF Applications: • Retail premises • Offices • Public buildings • Lobbies • Outdoor applications with limited relative humidity and vibration levels • Recommended luminaire classification IP54 or higher Ordering and packing data Ballast Ordering number Single unit Weight Bulk packing Qty. net kg pcs Dimensions Weight lxwxh gross cm kg 26 x 21.5 x 10 2.8 2.8 HID-PV C 035/S CDM 9137 100 40614 0.21 12 HID-PV C 035/P CDM 9137 120 03014 0.21 12 26 x 21.5 x 10 HID-PV C 035/I CDM 9137 120 03114 0.23 12 30.3 x 16.3 x 12.3 2.9 HID-PV C 035/F CDM 9137 120 00514 0.41 12 36 x 39.6 x 17.6 5.3 HID-PV C 070/S CDM 9137 100 40714 0.21 12 26 x 21.5 x 10 2.8 HID-PV C 070/P CDM 9137 100 40814 0.21 12 26 x 21.5 x 10 2.8 HID-PV C 070/I CDM 9137 100 41014 0.23 12 30.3 x 16.3 x 12.3 2.9 HID-PV C 070/F CDM 9137 120 06114 0.41 12 36 x 39.6 x 17.6 5.3 HID-PV C 150/S CDM 9137 106 14072 0.31 12 31 x 21.9 x 10.6 4.0 EH-S 2X035/S CDM 9137 100 41914 0.29 12 31 x 21.9 x 10.6 3.7 EH-S 2X035/P CDM 9137 100 43714 0.29 12 31 x 21.9 x 10.6 3.7 EH-S 2X035/I CDM 9137 100 43914 0.31 12 35.5 x 16.3 x 12.3 3.8 EH-S 2X035/F CDM 9137 120 00714 0.49 12 44 x 39.6 x 17.6 6.1 HID-PV m 020/P LPF HID-PV m 020/I CDM LPF Philips quality This assures optimum quality regarding: • System supplier As manufacturers of lamps and electronic control gear, Philips ensures that, from the earliest development stage, optimum lamp/ballast performance is maintained • European standards Philips HID electronic ballasts comply with all relevant international rules and regulations. HID-PV Dimensions in mm Compliances and approvals • Harmonics: EN 61000-3-2 EN 61547 • Immunity: • Safety: EN 60926 / EN 60928 / VDE 0712/ 14,22 • Performance: EN 60927 / EN 60929 • Approval marks: KEMA • CE marking • Environmental standard: ISO 14001 Overall length Product ID HID-PVm 3.14 High intensity discharge control gear Lamps and Gear A1 A2 B1 B2 C1 max. max. max. max. max. 97 88 43 34 4.2 Lamps and Gear High intensity discharge control gear 3.15 High intensity discharge control gear Electronics HID-PrimaVision mCDM Technical data For lamps System Lamp Tcase Tcase Tambient Power Power life max. range W W °C °C °C HID-PV m 1X020/S or /I CDM-Tm 20W 25 22 65 75 -20…50 HID-PV m 1X020/P CDM-Tm 20W 25 22 80 90 -20…50 Technical data for installation Mains operation Rated mains voltage With tolerances for performance: With tolerances for operation: Mains frequency Mains power factor Lamp operation Operation frequency (typical) Ignition voltage Air & creepage distance from any (metal) part that may come live, to earthed environment (class I) or test finger (class II) Cable capacity Mains current at 230 V Ballast 230V -10%/+6% 189 – 253V 50/60Hz 0.5 Nominal current HID-PV m 20/S or /P or /I 207 – 244V 100Hz 1.25kV 0,21 Inrush current Ballast Max. quantity of Inrush current ballast per 1/2 value time Miniature Circuit at typical mains Breaker impedance Type B 16 A HID-PV m 1X020/S, /I, /G or /P CDM 36 Connection wiring is greatly simplified by the use of cage-clamp contacts with push buttons. Wire cross-section: On the mains side: 0,75…1.5 mm2 On the lamp side: 0,75…1.5 mm2 >2.5 mm Max. 120 pF 48 hrs at 275 Vac 2 hrs at 320 Vac Automatic restart after lamp replacement or voltage dip, lamp may take up to 20 min to restart. High intensity discharge control gear Lamps and Gear Conversion table for max. quantities of ballasts on other types of Miniature Circuit Breaker MCB type advised rating: Uo/U = 250/250V advised rating: Uo/U = 250/250V 30 A / 400 µs. Strip length: Notes: For proper EMC wiring inside luminaire should be straight and as short as possible: mains wires should not run parallel to lamp wires. Thermo-protected circuit incorporates self-resetting facility; ignition attempts stop after 20 min; mains supply must switched off and on to reset ballast. 3.16 HID-PrimaVision mCDM Wiring diagram Ballast type Overvoltage protection Electronics 8 mm Ordering and packing data Rating Relative number of ballasts B 16 A 100% (see table above) B 10 A 63% net C 16 A 170% kg C 10 A 104% L, I 16 A 108% L, I 10 A 65% G, U, II 16 A 212% G, U, II 10 A 127% K, III 16 A 254% K, III 10 A 154% Ballast Ordering number Single unit Weight Bulk packing Qty. pcs Dimensions Weight lxwxh gross cm kg HID-PV m 020/S 9137 006 01466 0.088 12 18.5 x 11.5 x 12 1.12 HID-PV m 020/I 9137 006 01666 0.14 12 31.4 x 20.3 x 8.6 1.74 HID-PV m 020/P 9137 006 01566 0.06 12 18.5 x 11.5 x 12 0.78 Notes: 1. Data is based on a mains supply with an impedance of 400 mh (equal to 15 m cable of 2.5mm2 and other 20m to the middle of the power distribution), under worst-case conditions. With an impedance of 800mh the number of ballasts can be increased by 10%. 2. Measurements will be verified in real installations; therefore data are subject to change. 3. In some cases the maximum number of ballasts is not determined by the MCB but by the maximum electrical load of the installation. 4. Note that the maximum number of ballasts is given when these are all switched on at the same moment, i.e. by a wall switch. 5. Measurements were carried out on single-pole MCB’s. For multi-pole MCB’s it is advisable to reduce the number of ballasts by 20%. 6. The maximum number of ballasts which can be connected to one Residual Current Detector of 30mA is 60. Lamps and Gear High intensity discharge control gear 3.17