Electronics HID-PrimaVision CDM Electronics HID

advertisement
Electronics
HID-PrimaVision CDM
Electronics
HID-PrimaVision mCDM
Product Description
• Miniature, one-piece electronic ballast for Philips miniMaster CDMTm 20W ceramic metal halide lamps
• Developed together with the miniMaster CDM-Tm lamps for
optimum system performance
Wiring diagram
HID-PV C 35/70/150
EH-S 2X35
BALLAST
~
~ U mains
Features and Benefits:
Choice of versions:
• standard version (/S) with full polycarbonate/ABS housing
• with 2x strain relief (/I) for stand–alone applications
• PCB version (/P) for integration in luminaire
• Advantages in luminaire miniaturization and cable ratings due to
low-rated ignition voltage (<1.5 kV) compared with higher-wattage
CDM lamps (<5 kV)
• Microprocessor-controlled operation plus state-of-the-art software
based on Philips' expertise in compact HID lamp operation
4kV
Connection wiring is greatly simplified by the use of cage-clamp contacts with push buttons.
Wire cross-section:
On the mains side:
On the lamp side:
0.75…2.5 mm2
0.75…2.5 mm2
Strip length:
8 - 10 mm
HID-PV m 1X020/S CDM LPF
Applications:
• Retail premises
• Offices
• Public buildings
• Lobbies
• Outdoor applications with limited relative humidity and vibration
levels
• Recommended luminaire classification IP54 or higher
Ordering and packing data
Ballast
Ordering
number
Single unit
Weight
Bulk packing
Qty.
net
kg
pcs
Dimensions
Weight
lxwxh
gross
cm
kg
26 x 21.5 x 10
2.8
2.8
HID-PV C 035/S CDM
9137 100 40614
0.21
12
HID-PV C 035/P CDM
9137 120 03014
0.21
12
26 x 21.5 x 10
HID-PV C 035/I CDM
9137 120 03114
0.23
12
30.3 x 16.3 x 12.3
2.9
HID-PV C 035/F CDM
9137 120 00514
0.41
12
36 x 39.6 x 17.6
5.3
HID-PV C 070/S CDM
9137 100 40714
0.21
12
26 x 21.5 x 10
2.8
HID-PV C 070/P CDM
9137 100 40814
0.21
12
26 x 21.5 x 10
2.8
HID-PV C 070/I CDM
9137 100 41014
0.23
12
30.3 x 16.3 x 12.3
2.9
HID-PV C 070/F CDM
9137 120 06114
0.41
12
36 x 39.6 x 17.6
5.3
HID-PV C 150/S CDM
9137 106 14072
0.31
12
31 x 21.9 x 10.6
4.0
EH-S 2X035/S CDM
9137 100 41914
0.29
12
31 x 21.9 x 10.6
3.7
EH-S 2X035/P CDM
9137 100 43714
0.29
12
31 x 21.9 x 10.6
3.7
EH-S 2X035/I CDM
9137 100 43914
0.31
12
35.5 x 16.3 x 12.3
3.8
EH-S 2X035/F CDM
9137 120 00714
0.49
12
44 x 39.6 x 17.6
6.1
HID-PV m 020/P LPF
HID-PV m 020/I CDM LPF
Philips quality
This assures optimum quality regarding:
• System supplier
As manufacturers of lamps and electronic control gear, Philips
ensures that, from the earliest development stage, optimum
lamp/ballast performance is maintained
• European standards
Philips HID electronic ballasts comply with all relevant international
rules and regulations.
HID-PV
Dimensions in mm
Compliances and approvals
• Harmonics:
EN 61000-3-2
EN 61547
• Immunity:
• Safety:
EN 60926 / EN 60928 / VDE 0712/ 14,22
• Performance:
EN 60927 / EN 60929
• Approval marks:
KEMA
• CE marking
• Environmental standard: ISO 14001
Overall length
Product ID
HID-PVm
3.14
High intensity discharge control gear Lamps and Gear
A1
A2
B1
B2
C1
max.
max.
max.
max.
max.
97
88
43
34
4.2
Lamps and Gear High intensity discharge control gear
3.15
High intensity discharge control gear
Electronics
HID-PrimaVision mCDM
Technical data
For lamps
System
Lamp
Tcase
Tcase
Tambient
Power
Power
life
max.
range
W
W
°C
°C
°C
HID-PV m 1X020/S or /I
CDM-Tm 20W
25
22
65
75
-20…50
HID-PV m 1X020/P
CDM-Tm 20W
25
22
80
90
-20…50
Technical data for installation
Mains operation
Rated mains voltage
With tolerances for performance:
With tolerances for operation:
Mains frequency
Mains power factor
Lamp operation
Operation frequency (typical)
Ignition voltage
Air & creepage distance from any
(metal) part that may come live, to
earthed environment (class I) or test
finger (class II)
Cable capacity
Mains current at 230 V
Ballast
230V
-10%/+6%
189 – 253V
50/60Hz
0.5
Nominal current
HID-PV m 20/S or /P or /I
207 – 244V
100Hz
1.25kV
0,21
Inrush current
Ballast
Max. quantity of
Inrush current
ballast per
1/2 value time
Miniature Circuit
at typical mains
Breaker
impedance
Type B 16 A
HID-PV m 1X020/S, /I, /G or /P CDM
36
Connection wiring is greatly simplified by the use of cage-clamp contacts with push buttons.
Wire cross-section:
On the mains side: 0,75…1.5 mm2
On the lamp side: 0,75…1.5 mm2
>2.5 mm
Max. 120 pF
48 hrs at 275 Vac
2 hrs at 320 Vac
Automatic restart after lamp replacement or voltage dip, lamp may take
up to 20 min to restart.
High intensity discharge control gear Lamps and Gear
Conversion table for max. quantities of ballasts on other
types of Miniature Circuit Breaker
MCB type
advised rating: Uo/U = 250/250V
advised rating: Uo/U = 250/250V
30 A / 400 µs.
Strip length:
Notes:
For proper EMC wiring inside luminaire should be straight and as short
as possible: mains wires should not run parallel to lamp wires.
Thermo-protected circuit incorporates self-resetting facility; ignition
attempts stop after 20 min; mains supply must switched off and on to
reset ballast.
3.16
HID-PrimaVision mCDM
Wiring diagram
Ballast type
Overvoltage protection
Electronics
8 mm
Ordering and packing data
Rating
Relative number of ballasts
B
16 A
100% (see table above)
B
10 A
63%
net
C
16 A
170%
kg
C
10 A
104%
L, I
16 A
108%
L, I
10 A
65%
G, U, II
16 A
212%
G, U, II
10 A
127%
K, III
16 A
254%
K, III
10 A
154%
Ballast
Ordering
number
Single unit
Weight
Bulk packing
Qty.
pcs
Dimensions
Weight
lxwxh
gross
cm
kg
HID-PV m 020/S
9137 006 01466
0.088
12
18.5 x 11.5 x 12
1.12
HID-PV m 020/I
9137 006 01666
0.14
12
31.4 x 20.3 x 8.6
1.74
HID-PV m 020/P
9137 006 01566
0.06
12
18.5 x 11.5 x 12
0.78
Notes:
1. Data is based on a mains supply with an impedance of 400 mh
(equal to 15 m cable of 2.5mm2 and other 20m to the middle of the
power distribution), under worst-case conditions. With an impedance
of 800mh the number of ballasts can be increased by 10%.
2. Measurements will be verified in real installations; therefore data are
subject to change.
3. In some cases the maximum number of ballasts is not determined by
the MCB but by the maximum electrical load of the installation.
4. Note that the maximum number of ballasts is given when these are
all switched on at the same moment, i.e. by a wall switch.
5. Measurements were carried out on single-pole MCB’s. For multi-pole
MCB’s it is advisable to reduce the number of ballasts by 20%.
6. The maximum number of ballasts which can be connected to one
Residual Current Detector of 30mA is 60.
Lamps and Gear High intensity discharge control gear