Wiring Diagrams ACCESSORY ELECTRIC HEATERS FAN COIL MODEL WITH FACTORY INSTALLED HEAT PF1MNA018,024,030,036,005AAAA PF1MNA018,024,030,036,008AAAA PF1MNA018,024,030,036,010AAAA FIELD INSTALLED HEATER MODEL KFCEH0401N03 KFCEH0501N05 KFCEH0601C05 KFCEH0801N08 KFCEH1001C08 KFCEH1409N09* KFCEH0901N10 KFCEH1501F15* KFCEH1701C15* KFCEH1801F20* KFCEH1901C20* KFCEH1601315 KFCEH2001318 KFCEH2101F24* KFCEH2201F30* Fan Coils FACTORY INSTALLED HEATER MODEL MKFECH0501N05 MKFECH0801N08 MKFECH0901N09 NOM KW 240 V NOMINAL KW DESCRIPTION 5 Non-fused 8 Non-fused 10 Non-fused LABEL DIAGRAM Fig. 1 HEATER INSTALLED IN PF1MNA018, 024, 030, 036, 042, 048, 060 FAN COIL HEATER INSTALLED IN PF1MNA071 FAN COIL Fig. 1 Fig. 2 Fig. 3† Fig. 1 Fig. 4† Fig. 2 Fig. 5† Fig. 6† Fig. 7† Fig. 8† Fig. 9 Fig. 11 Fig. 10 Fig. 12 Single Phase Fig. 13 Three Phase Fig. 15 Single Phase Fig. 14 Three Phase Fig. 16 3 Non-Fused 5 Non-Fused 5 Circuit Breaker 8 Non-Fused 8 Circuit Breaker 9 Non-Fused 1 or 3-Phase 10 Non-Fused 15 Fused Dual Circuit 15 Circuit Breaker Dual Circuit 20 Fused Dual Circuit 20 Circuit Breaker Dual Circuit 15 Non-Fused 3-Phase Only 18 Non-Fused 3-Phase Only 24 Fused 1 or 3 Phase Single or Multiple Circuit 30 Fused 1 or 3 Phase Single or Multiple Circuit † For heater serial numbers after 1900A56372 FIELD INSTALLED HEATER MODEL KFDEH0801D05 KFDEH0901D75 KFDEH1001D11 ACCESSORY SMART HEAT PACKAGES KFCEH0101H10 KFCEH0201H15 KFCEH0301H20 NOM KW 240 V HEATER INSTALLED IN FF1D FAN COIL 5 Disconnect 7.5 Disconnect 11 Disconnect Fig. 17 NOM KW AT 240 V LABEL DIAGRAM 10 Smart Heat 15 Smart Heat 20 Smart Heat Fig. 18 Fig. 19 Fig. 20 FAN COIL WITH COOLING ONLY CONTROL PF1MN018,024,030,036,042,048,060,070000AAAA PF1MN071000AAAA Form: WD-PF1M-01 Cancels: New Printed in U.S.A. LABEL DIAGRAM Fig. 21 Fig. 22 6-01 Catalog No. 53PF-1M2 CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE SCHEMATIC DIAGRAM FIELD POWER WIRING HTR1 HTR2 LS1 OR L1 COMPONENT ARRANGEMENT DISCONNECT PER NEC SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 OR OR CB L2 DISC DISC L1 OR LS2 L2 R1 CB COM GND SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 8.4VA REMAINING VA AVAILABLE: 31.6VA TRAN RED 24 V YEL 208 V 230 V BRN HTR2 LS2 BLK YEL LS1 HTR1 BLK BLK 6 8 RELAY 1 2 4 BLU RELAY 1 BLK BLK 6 2 8 4 1 YEL 11 11 9 9 REC BLK BLU ORN BLU L2 VIO 3 3 7 7 0 C T1 R G REC RELAY 1 22 VDC COIL PLUG 6 1 6 1 2 2 L1 NC CB 4 4 PCB 60A 60A NO FR RECP BLK F SPT BRN COM HI MED LO BRN YEL BLK BLU RED C RED TRAN GRN/YEL GND W2 BLU-MED BLK-HI GRN/YEL-GND R W WHT BARRIER BRN INDOOR THERMOSTAT G SEE NOTE #7 OUTDOOR UNIT NOTES: 1. USE COPPER WIRE (75°C MIN) ONLY BETWEEN DISCONNECT SWITCH AND UNIT. 2. TO BE WIRED IN ACCORDANCE WITH NEC AND LOCAL CODES. 3. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. 4. REPLACE LOW VOLTAGE FUSE WITH NO GREATER THAN 5 AMP FUSE. 5. (3) SPEED MOTOR SHOWN. OPTIONAL (2) SPEED MOTOR USES HI (BLK) AND LOW (BLU OR RED). 6. SMALLER HEATERS WILL HAVE FEWER COMPONENTS. 7. CONNECT R TO R, G TO G, ETC., SEE OUTDOOR INSTRUCTION 324988-101 REV. A FOR DETAILS. FM BRN BRN YEL-COM CAP SEE NOTE #5 FAN MOTOR THERMALLY PROTECTED LEGEND BRN FM GRY 230V GND VIO 208 V BRN BLU YEL COM CAP RED-LOW WHT PCB BLK YEL GRY RED RED G R F T1 C NO FR BRN NC SPT CAP CB COM F FM FR FU GND SPT CAPACITOR CIRCUIT BREAKER COMMON LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING PCB FAN RELAY LINE FUSE EQUIPMENT GROUND FAN SPEED TAP LOCATION HTR LS HEATER LIMIT SWITCH MARKED TERMINAL PLUG AND RECEPTACLE PCB PRINTED CIRCUIT BOARD REC RECTIFIER R TRAN RELAY TRANSFORMER UNMARKED TERMINAL MINIMUM MOTOR SPEED SELECTION 018 024 030 036 042 048 060 070 FAN COIL SIZE MOTOR SPEED ONE HTR LO LO LO LO -- -- -- -MOTOR SPEED TWO HTR LO LO LO LO LO LO LO LO A00168 Fig. 1—Label Wiring 324988-101 —2— THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE LEGEND COM F1 ICM SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT SEE RATING PLATE FOR VOLTS & HERTZ DISCONNECT PER NEC SEE NOTE #1 OR OR L1 OR CB OR L2 DISC DISC L1 FU GND HVTB HTR REC L2 CB HTR2 LS2 LS1 HTR1 BLK BLK 6 RELAY 1 FIELD POWER WIRING L1 BLK 9 11 208/240VAC 9 11 RELAY 1 22 VDC COIL BLK REC BLU BLK 7 7 11 11 3 3 7 3 2 24VAC 3 2 7 PLUG 2 4 24VAC RECP 2 4 6 1 6 1 COMPONENT ARRANGEMENT VIO ORN HTR1 PLUG 9 9 L2 YEL BLK 2 4 BLU YEL PCB TRAN RECP CB R TDR LIMIT SWITCH MARKED TERMINAL PLUG AND RECEPTACLE PRINTED CIRCUIT BOARD TRANSFORMER RECEPTACLE CIRCUIT BREAKER RELAY TIME DELAY RECTIFIER FIELD POWER WIRING BLK 8 YEL LS COOLING CONTROL ONLY GND YEL COMMON LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING LINE FUSE EQUIPMENT GROUND HIGH VOLTAGE TERM BLOCK HEATER RECTIFIER 2 2 6 1 6 1 LS1 LS2 24 V RECP 2 BRN COM HTR2 RED 4 4 TRAN FIELD POWER WIRING 208 V BRN 230 V R1 YEL Com 208V BLK 230V SEC1 SEC2 AUX HEAT KW/CFM KW CFM R W 1 VIO F1 BRN AC/HP SIZE 12 9 8 7 VI RE BR OR O D N N 10 BLU 6 2 1 ORN BLK NOM G HI LO BLK YEL PLUG 3 O 0 90 ON/OFF DELAY 30 0 90 0 HI C WHT AUX1 HUM1 CONTINUOUS FAN LO MED HI 5 4 3 2 1 BLK WHT VIO BLK BLU ORN BRN 2 SEC1 SEC2 PCB D H 4 8 R 0 1 F1 REC W 1 W2 Y 1 Y/Y 2 G O C PL1 GND HEATER / MOTOR 24 VAC 1 ICM GRY HEATER / MOTOR 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 6 AUX 2 HUM2 YEL PL1 GRN WHT VIO ORN YEL RED GRY 60A 60A YEL GRN/YEL PLUG 1 L1 RELAY 1 Y/Y 2 HP-EFF AC/HP CFM ADJUST BLK GR Y B W N EL LK HT 3 HP-COMFORT ORN WHT 5 4 AC L2 CB Y 1 SYSTEM TYPE 11 SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 4.8VA REMAINING VA AVAILABLE: 35.2VA W 2 BLU GR Y VIO RED VIO D H OUTDOOR UNIT TRAN PCB INDOOR THERMOSTAT RED BRN GND NOTES: 1. RECP 3 2. 3. 4. ICM RECP 4 GRY PLUG 4 5. 6. 7. 8. USE COPPER WIRE (75*C MIN) ONLY BETWEEN DISCONNECT SWITCH AND UNIT. TO BE WIRED IN ACCORDANCE WITH NEC AND LOCAL CODES. TRANSFORMER PRIMARY LEADS, BLUE 208V, RED 230V. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. REPLACE LOW VOLTAGE FUSE WITH NO GREATER THAN 5 AMP FUSE. DUAL CIRCUIT WIRING SHOWN. USE 60 AMP CLASS K FUSES ONLY, FOR REPLACEMENT. CONNECT R TO R, G TO G, ETC., SEE OUTDOOR INSTRUCTION FOR DETAILS. 326001-101 REV. B LABEL (2) SEE INSTRUCTION FOR INSTALLATION A00183 Fig. 2—Label Wiring 326001-101 —3— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT SEE RATING PLATE FOR VOLTS & HERTZ GND COMPONENT ARRANGEMENT DISCONNECT PER NEC HTR1 SEE NOTE #1 BLU L1 LS1 YEL YEL L3 HTR1 BLK YEL LS3 BLK BLU REC COM BRN HI MED YEL BLK BLU LO RED NOTE: NOTES: COM 208V 230V BRN RED TRAN FM GRN/YEL GND BRN 4 230 V 0 6 2 8 4 C T1 R G 4 4 0 1 F NC REC GRY RED PCB NO FR SPT BRN W2 W3 E VIO YEL CAP BLK PCB BRN RELAY 2 BLU F T1 C YEL 8 208 V BRN 6 1 6 1 WHT G R NO FR 24 V REC BRN NC SPT 2 2 BLK RED BLU 3 3 BRN RECP 7 7 2 RED-LOW GRY 11 11 6 1 REC RED VIO ORN BLK RED RELAY 1 PLUG 9 9 R2 COM SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 15.2VA REMAINING VA AVAILABLE: 24.8VA RELAY 1 22 VDC COIL BLU LS2 R1 RELAY 2 22 VDC COIL YEL LS3 BLU RELAY 2 6 8 RELAY 1 HTR3 BLK 2 4 YEL HTR2 BLK 2 4 BLU LS2 HTR2 BLU BLU LS1 L2 RELAY 2 HTR3 TRAN FIELD POWER WIRING GND C R W2 G WHT SEE NOTE #7 BARRIER SEE NOTE #6 INDOOR THERMOSTAT OUTDOOR UNIT FOR 3 PHASE WIRING Denotes wire to be moved for 3 phase conversion. Dashed wire (- - -) indicates wiring after conversion. 1. Disconnect BLUE wire from limit switch 3(LS3), cut, strip, and connect to field wire L3. 2. Disconnect YELLOW wire from LS1 and connect to LS3. 3. Disconnect BLUE wire from relay 2 terminal 2 and connect to LS1. 1. USE COPPER WIRE (75°C MIN) ONLY BETWEEN DISCONNECT SWITCH AND UNIT. 2. TO BE WIRED IN ACCORDANCE WITH NEC AND LOCAL CODES. 3. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. 4. REPLACE LOW VOLTAGE FUSE WITH NO GREATER THAN 5 AMP FUSE. 5. (3) SPEED MOTOR SHOWN. OPTIONAL (2) SPEED MOTOR USES HI (BLK) AND LOW (BLU OR RED). 6. CONNECT R TO R, G TO G, ETC., SEE OUTDOOR INSTRUCTION FOR DETAILS. 7. IF WIRE CRIMP IS REMOVED AN EMERGENCY HEAT RELAY IS REQUIRED. (SEE OUTDOOR-THERMOSTAT INSTRUCTIONS) SEE NOTE #5 BLU-MED BLK-HI GRN/YEL-GND FM BRN BRN YEL-COM CAP FAN MOTOR THERMALLY PROTECTED LEGEND CAP COM CAPACITOR COMMON F FM LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING PCB FAN RELAY EQUIPMENT GROUND FAN SPEED TAP LOCATION FR GND SPT R RELAY HTR LS HEATER LIMIT SWITCH MARKED TERMINAL PLUG & RECEPTACLE PCB PRINTED CIRCUIT BOARD REC RECTIFIER R RELAY TRAN TRANSFORMER UNMARKED TERMINAL MINIMUM CFM / MOTOR SPEED SELECTION FAN COIL SIZE 018 024 030 036 042 048 060 070 MOTOR SPEED AT 9 KW -- LO LO LO LO LO LO LO 325650-101 REV. A A00175 Fig. 3—Label Wiring 325650-101 —4— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE LEGEND SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT SEE RATING PLATE FOR VOLTS & HERTZ GND DISCONNECT PER NEC FU GND HVTB HTR REC SEE NOTE #1 BLU L3 L1 LS1 YEL YEL YEL RELAY 2 BLK 2 4 BLU RELAY 2 6 8 RELAY 1 HTR3 BLK 2 4 LS3 YEL RELAY 2 22 VDC COIL REC 9 9 BLK 7 7 11 11 3 3 RED 2 2 6 1 6 1 RED BRN YEL Com 208V BLK 230V VIO F1 9 8 7 GR Y BLU VI RE BR OR O D N N 10 6 2 1 HP-COMFORT HP-EFF ORN BLK NOM LO G HI BLK YEL PLUG 3 O ON/OFF DELAY 0 30 0 90 90 0 HI 5 4 3 2 1 AUX1 HUM1 GND BLK WHT VIO BLK BLU ORN BRN 208 V 230 V BRN FU4 FU2 FU1 FU3 8 PCB D H 4 R 0 1 F1 W 1 REC W2 RELAY 2 Y 1 Y/Y 2 G 6 2 8 4 O C 0 1 TDR 24 VAC 1 PL1 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 SEC1 SEC2 AUX 2 HUM2 YEL R2 2 6 YEL GRN/YEL PLUG 1 GRN WHT VIO ORN YEL RED GRY C WHT CONTINUOUS FAN LO MED HI 24 V RELAY 1 Y/Y 2 AC/HP CFM ADJUST BLK GR Y BL W N EL K HT 3 AC COM RED L4 L2 L1 L3 L4 L3 L2 L1 CB2 CB1 60A 60A 60A 60A Y 1 ORN WHT 5 4 BLU 6 1 PLUG 2 4 24VAC RECP 2 4 HTR2 LS2 R1 W 2 SYSTEM TYPE 11 RED VIO R W 1 BRN VIO HTR3 LS3 D H AC/HP SIZE 12 HTR1 LS1 AUX HEAT KW/CFM 6 1 COMPONENT ARRANGEMENT RECP 2 SEC2 KW CFM 3 2 24VAC 3 2 7 4 4 PCB SEC1 7 11 208/240VAC 11 9 BRN BRN TRAN BLK YEL OUTDOOR UNIT PLUG REC VIO ORN SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 6.5VA REMAINING VA AVAILABLE: 33.5VA L2 9 INDOOR THERMOSTAT BLU FIELD POWER WIRING L1 BLK YEL LIMIT SWITCH MARKED TERMINAL PLUG AND RECEPTACLE PCB PRINTED CIRCUIT BOARD TRAN TRANSFORMER RECP RECEPTACLE CB CIRCUIT BREAKER R RELAY TDR TIME DELAY RECTIFIER COOLING CONTROL ONLY RELAY 1 22 VDC COIL BLU LS FIELD POWER WIRING BLU HTR2 BLU LS2 BLU L2 HTR1 BLK COMMON LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING LINE FUSE EQUIPMENT GROUND HIGH VOLTAGE TERM BLOCK HEATER RECTIFIER TRAN FIELD POWER WIRING COM F1 ICM PL1 GRY HEATER / MOTOR HEATER / MOTOR ICM RECP 3 GND ICM NOTES: 1. RECP 4 GRY PLUG 4 FOR 3 PHASE WIRING Denotes wire to be moved for 3 phase conversion. Dashed wire (- - -) indicates wiring after conversion. 1. Disconnect BLUE wire from limit switch 3(LS3), cut, strip, and connect to field wire L3. 2. Disconnect YELLOW wire from LS1 and connect to LS3. 3. Disconnect BLUE wire from relay 2 terminal 2 and connect to LS1. 2. 3. 4. 5. 6. 7. 8. USE COPPER WIRE (75*C MIN) ONLY BETWEEN DISCONNECT SWITCH AND UNIT. TO BE WIRED IN ACCORDANCE WITH NEC AND LOCAL CODES. TRANSFORMER PRIMARY LEADS, BLUE 208V, RED 230V. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. REPLACE LOW VOLTAGE FUSE WITH NO GREATER THAN 5 AMP FUSE. DUAL CIRCUIT WIRING SHOWN. USE 60 AMP CLASS K FUSES ONLY, FOR REPLACEMENT. CONNECT R TO R, G TO G, ETC., SEE OUTDOOR INSTRUCTION FOR DETAILS. 325796-101 REV. B LABEL (2) SEE INSTRUCTION FOR INSTALLATION A00179 Fig. 4—Label Wiring 325796-101 —5— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE (LADDER FORMAT) COMPONENT ARRANGEMENT DISCONNECT PER NEC SEE RATING PLATE FOR VOLTS & HERTZ HTR1 LS1 SEE NOTE #1 L4 L3 CB1 HTR2 LS2 LS3 L2 CB2 CB1 SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 11.8VA REMAINING VA AVAILABLE: 28.2VA COM RED 24 V RELAY 1 YEL YEL LS2 HTR2 BLK YEL LS1 LS3 HTR1 HTR3 BLK BLK YEL RELAY 2 4 2 RELAY 2 6 4 RELAY 1 2 11 11 9 9 BLU RELAY 2 22 VDC COIL 7 7 3 3 VIO 2 2 RED BRN 6 1 6 1 COM HI MED LO BRN YEL BLK BLU RED RED TRAN FM GRN/YEL GND BRN L2 PCB L1 CB2 GRY VIO BLU SEE NOTE #6 NO FR SPT 60A 60A 60A 60A GND BLU-MED BLK-HI GRN/YEL-GND FM BRN BRN YEL-COM CAP FAN MOTOR THERMALLY PROTECTED LEGEND C R WHT W BARRIER G SEE NOTE #8 INDOOR THERMOSTAT SEE NOTE #7 OUTDOOR UNIT NOTES: 1. 2. 3. 4. 5. 6. 7. 8. L3 CB1 COM 208V 230V BRN F NC L4 W2 BRN WHT YEL CAP C T1 R G RED-LOW RED PCB BLK YEL GND 0 GRY RED BRN FR 4 PLUG 4 4 BLK G R F T1 C 8 FU4 FU2 FU1 FU3 L4 L2 L1 L3 TDR RECP NO 2 1 BRN SPT 6 230 V BLK ORN NC 4 0 BLK R EC BLK 8 208 V BRN REC RELAY 2 TDR BLU 2 1 BLK 8 BLU 6 BLK RELAY 1 22 VDC COIL YEL R2 R1 INTERNAL PROTECTION MAY BE EITHER FUSES OR CIRCUIT BREAKERS CB2 L4 L2 FU2 FU3 L1 FU4 L3 FU1 GND L1 HTR3 TRAN SCHEMATIC DIAGRAM FIELD POWER WIRING Use copper wire (75°C min.) only between disconnect switch and unit. To be wired in accordance with N.E.C. and local codes. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire. Replace low voltage fuse with no greater than 5 amp fuse. Use 60 amp class K fuses only, for replacement. (3) speed motor shown. Optional (2) speed motor uses HI (BLK) and LOW (BLU or RED). Connect R to R, G to G, etc., see outdoor instruction for details. If wire crimp is removed an emergency heat relay is required. (See outdoor-thermostat instructions). CB CAP COM F FM FR FU GND SPT CIRCUIT BREAKER CAPACITOR COMMON LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING PCB FAN RELAY LINE FUSE EQUIPMENT GROUND FAN SPEED TAP LOCATION HTR LS PCB REC R TRAN TDR HEATER LIMIT SWITCH MARKED TERMINAL PLUG AND RECEPTACLE PRINTED CIRCUIT BOARD RECTIFIER RELAY TRANSFORMER UNMARKED TERMINAL TIME DELAY RECTIFIER MINIMUM MOTOR SPEED SELECTION 018 024 030 036 042 048 060 070 FAN COIL SIZE MOTOR SPEED AT 15 KW -- MED LO LO LO LO LO LO 325651-101 REV. A A00176 Fig. 5—Label Wiring 325651-101 —6— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING BLOWER MOTOR ROTATION NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT SEE RATING PLATE DISCONNECT PER NEC FOR VOLTS & HERTZ SEE NOTE #1 LEGEND L1 FU3 CB1 GND L3 L4 CB2 INTERNAL PROTECTION MAY BE EITHER FUSES OR CIRCUIT BREAKERS CB2 L2 CB1 L4 L2 FU2 L3 FU4 L1 FU1 FIELD POWER WIRING COM F1 ICM FU GND HVTB HTR REC COMMON LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING LINE FUSE EQUIPMENT GROUND HIGH VOLTAGE TERM BLOCK HEATER RECTIFIER LS LIMIT SWITCH MARKED TERMINAL PLUG AND RECEPTACLE PCB PRINTED CIRCUIT BOARD TRAN TRANSFORMER RECP RECEPTACLE CB CIRCUIT BREAKER R RELAY TDR TIME DELAY RECTIFIER FIELD POWER WIRING HTR2 RELAY 2 4 2 BLK YEL HTR1 BLK LS3 HTR3 BLK LS1 YEL BLK 6 RELAY 1 2 4 YEL BLU FIELD POWER WIRING RELAY 2 8 YEL COOLING CONTROL ONLY BLK BLK L1 L2 BLK YEL BLK 9 11 7 208/240VAC 11 7 9 RELAY 2 22 VDC COIL RELAY 1 22 VDC COIL REC YEL BLU PLUG 9 9 REC VIO ORN BLK 7 7 11 11 SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 6.5VA REMAINING VA AVAILABLE: 33.5VA 3 3 RED 2 2 3 2 24VAC 3 2 COMPONENT ARRANGEMENT HTR1 6 1 6 1 HTR3 LS1 LS3 LS2 24 V RECP 2 SEC2 AUX HEAT KW/CFM KW CFM VIO F1 BRN AC/HP SIZE R2 12 11 9 8 7 VI RE BR OR O D N N 10 BLU 6 2 1 ORN BLK NOM G HI LO BLK YEL PLUG 3 O 0 90 ON/OFF DELAY 30 0 90 0 HI C WHT AUX1 HUM1 CONTINUOUS FAN LO MED HI 5 4 3 2 1 BLK WHT VIO BLK BLU ORN BRN PCB D H 4 8 R 0 1 F1 REC W 1 W2 Y 1 Y/Y 2 G RELAY 2 6 2 8 4 O C 0 1 TDR PL1 GND HEATER / MOTOR 24 VAC 1 ICM GRY HEATER / MOTOR 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 SEC1 SEC2 AUX 2 HUM2 YEL PL1 GRN WHT VIO ORN YEL RED GRY FU4 FU2 FU1 FU3 YEL GRN/YEL PLUG 1 230 V 2 6 Y/Y 2 HP-EFF AC/HP CFM ADJUST BLK GR Y BL W N EL K HT 3 HP-COMFORT ORN WHT 5 4 AC 208 V BRN RELAY 1 Y 1 SYSTEM TYPE L4 L2 L1 L3 L4 L3 L2 L1 CB2 CB1 60A 60A 60A 60A W 2 BLU GR Y VIO RED VIO R W 1 OUTDOOR UNIT BLK 230V SEC1 D H INDOOR THERMOSTAT YEL Com 208V PCB COM HTR2 RED 4 4 R1 TRAN 6 1 PLUG 2 4 24VAC RECP 2 4 BRN BRN RED BRN 6 1 TRAN LS2 GND NOTES: 1. RECP 3 2. 3. 4. ICM RECP 4 GRY PLUG 4 5. 6. 7. 8. USE COPPER WIRE (75*C MIN) ONLY BETWEEN DISCONNECT SWITCH AND UNIT. TO BE WIRED IN ACCORDANCE WITH NEC AND LOCAL CODES. TRANSFORMER PRIMARY LEADS, BLUE 208V, RED 230V. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. REPLACE LOW VOLTAGE FUSE WITH NO GREATER THAN 5 AMP FUSE. DUAL CIRCUIT WIRING SHOWN. USE 60 AMP CLASS K FUSES ONLY, FOR REPLACEMENT. CONNECT R TO R, G TO G, ETC., SEE OUTDOOR INSTRUCTION FOR DETAILS. 325797-101 REV. B LABEL (2) SEE INSTRUCTION FOR INSTALLATION A00180 Fig. 6—Label Wiring 325797-101 —7— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE SCHEMATIC DIAGRAM COMPONENT ARRANGEMENT DISCONNECT PER NEC SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 HTR3 HTR1 CB1 GND YEL LS3 HTR3 BLK LS2 HTR2 BLK YEL LS1 HTR1 HTR4 LS4 YEL BLK BLK L4 L2 CB2 INTERNAL PROTECTION MAY BE EITHER FUSES OR CIRCUIT BREAKERS YEL YEL L4 CB1 L2 RELAY 3 4 2 RELAY 2 4 2 RELAY 2 8 6 RELAY 1 2 4 R3 RELAY 1 BLK 6 2 8 4 1 BLK 0 6 2 RELAY 2 22 VDC COIL BLK 8 4 0 1 TDR RELAY 3 RELAY 1 22 VDC COIL 22 VDC COIL RED BRN RED 24 V BRN 2 8 4 C T1 R G REC REC 11 11 BLU PCB YEL CO M CAP HI MED LO BRN YEL BLK BLU RED BRN GRY RED G R NO BLK F T1 C FM GND BRN SEE NOTE #6 208V 230V C R BRN GRN YEL GND FR TDR W2 YEL COM BLK NC FR 4 4 PCB 0 1 VIO SPT 3 3 7 7 BLU RECP BRN VIO 6 1 2 2 6 1 WHT 9 9 ORN RED PLUG BLK GRY BLU GRY BRN YEL RED TRAN BRN W WHT G BARRIER SEE NOTE #8 INDOOR THERMOSTAT OUTDOOR UNIT NOTES: 1. Use copper wire (75*C min.) only between disconnect switch and unit. 2. To be wired in accordance with N.E.C. and local codes. 3. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire. 4. Replace low voltage fuse with no greater than 5 amp fuse. 5. Use 60 amp class K fuses only, for replacement. 6. (3) speed motor shown. Optional (2) speed motor uses HI (BLK) and LOW (BLU or RED). 7. Connect R to R, G to G, etc., see outdoor instruction for details. 8. Smaller heaters will have fewer components. 325652-101 REV. A 208 V 230 V GND TDR RELAY 3 6 R2 COM FU4 FU2 FU1 FU3 L4 L2 L1 L3 BLK BLU R1 SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 11.8VA REMAINING VA AVAILABLE: 28.2VA REC RELAY 2 BLK LS2 HTR4 L3 CB2 FU2 FU3 FU1 L1 FU4 L3 L1 HTR2 LS 3 & 4 LS1 TRAN FIELD POWER WIRING F NC NO L4 L3 L2 L1 CB1 CB2 60A 60A 60A 60A SPT RED-LOW BLU-MED BLK-HI FM BRN BRN YEL-COM CAP GRN/YEL-GND FAN MOTOR THERMALLY PROTECTED LEGEND HTR LS HEATER LIMIT SWITCH MARKED TERMINAL PLUG AND RECEPTACLE PRINTED CIRCUIT PCB BOARD RECTIFIER REC R RELAY TRAN TRANSFORMER UNMARKED TERMINAL TIME DELAY TDR RECTIFIER MINIMUM MOTOR SPEED SELECTION CB CIRCUIT BREAKER CAP CAPACITOR COM COMMON LOW VOLTAGE FUSE F FM FAN MOTOR FIELD POWER WIRING FR PCB FAN RELAY FU LINE FUSE GND EQUIPMENT GROUND SPT FAN SPEED TAP LOCATION FAN COIL SIZE MOTOR SPEED AT 20 KW 018 024 030 036 042 048 060 070 -- -- MED LO LO LO LO LO A00177 Fig. 7—Label Wiring 325652-101 —8— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATI ON ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE LEGEND 20KW 1PH SCHEMATI C DIAGRAM L3 CB2 GND LS2 HTR2 BLK YEL LS1 HTR1 BLK HTR4 LS4 YEL L4 L2 CB1 RELAY 3 4 2 RELAY 2 4 2 RELAY 2 6 8 RELAY 1 2 4 LS3 HTR3 BLK YEL YEL CB2 INTERNAL PROTECTION MAY BE EITHER FUSES OR CIRCUIT BREAKERS YEL L2 L4 BLK FU GND HVTB HTR REC BLK BLK RELAY 2 22 VDC COIL BLK L1 BRN PLUG 2 4 4 6 1 6 1 YEL Com 208V BLK 230V PCB SEC1 AUX HEAT KW/CFM KW CFM VIO BRN 11 9 8 7 VI RE BR OR O D N N 10 BLU 6 2 1 ORN BLK NOM G HI LO BLK YEL PLUG 3 O 0 90 ON/OFF DELAY 30 0 90 0 HI C WHT AUX1 HUM1 CONTINUOUS FAN LO MED HI 5 4 3 2 1 YEL BLK WHT VIO BLK BLU ORN BRN 230 V FU4 FU2 FU1 FU3 2 8 PCB D H 4 R 0 1 F1 REC RELAY 2 6 2 8 4 Y 1 Y/Y 2 G O 0 1 C TDR RELAY 3 6 2 8 4 W 1 W2 PL1 GND 24 VAC 0 1 1 HEATER / MOTOR ICM REC GRY HEATER / MOTOR 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 L4 L2 L1 L3 208 V BRN AUX 2 HUM2 PL1 GRN WHT VIO ORN YEL RED GRY R2 SEC1 SEC2 YEL GRN/YEL PLUG 1 6 Y/Y 2 HP-EFF AC/HP CFM ADJUST BLK GR Y BL W N EL K HT 3 HP-COMFORT ORN WHT 5 4 AC R1 24 V RELAY 1 Y 1 SYSTEM TYPE PLUG 2 4 24VAC RECP 2 4 COM R3 L4 L3 L2 L1 CB2 CB1 60A 60A 60A 60A W 2 BLU GR Y 12 RED VIO F1 AC/HP SIZE VIO R W 1 6 1 RED LS2 D H SEC2 6 1 HTR2 LS 3 & 4 LS1 RECP 2 FU3 TRAN HTR3 HTR1 HTR4 2 2 GRY 3 2 24VAC 3 2 COMPONENT ARRANGEMENT OUTDOOR UNIT 3 3 RELAY 3 22 VDC COIL BRN BRN RED BRN BLK REC REC VIO ORN 7 7 11 11 L2 11 7 208/240VAC 11 7 9 INDOOR THERMOSTAT 9 9 RED SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 8.2VA REMAINING VA AVAILABLE: 31.8VA 9 TDR BLK FIELD POWER WIRING YEL RELAY 1 22 VDC COIL BLU LIMIT SWITCH MARKED TERMINAL PLUG AND RECEPTACLE PCB PRINTED CIRCUIT BOARD TRAN TRANSFORMER RECP RECEPTACLE CB CIRCUIT BREAKER R RELAY TDR TIME DELAY RECTIFIER FIELD POWER WIRING BLK YEL LS COOLING CONTROL ONLY BLK BLU YEL COMMON LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING LINE FUSE EQUIPMENT GROUND HIGH VOLT AGE TERM BLOCK HEATER RECTIFIER TRAN FU1 L1 CB1 FU2 L3 L1 COM F1 ICM DISCONNECT PER NEC SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 FU4 FIELD POWER WIRING GND NOTES: 1. RECP 3 2. 3. 4. ICM RECP 4 GRY PLUG 4 5. 6. 7. 8. USE COPPER WIRE (75*C MIN) ONLY BETWEEN DISCONNECT SWITCH AND UNIT. TO BE WIRED IN ACCORDANCE WITH NEC AND LOCAL CODES. TRANSFORMER PRIMARY LEADS, BLUE 208V, RED 230V. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. REPLACE LOW VOLTAGE FUSE WITH NO GREATER THAN 5 AMP FUSE. DUAL CIRCUIT WIRING SHOWN. USE 60 AMP CLASS K FUSES ONLY, FOR REPLACEMENT. CONNECT R TO R, G TO G, ETC., SEE OUTDOOR INSTRUCTION FOR DETAILS. 325653-101 REV. B LABEL (2) SEE INSTRUCTION FOR INSTALLATION A00178 Fig. 8—Label Wiring 325653-101 —9— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 COMPONENT ARRANGEMENT DISCONNECT PER NEC HTR1 GND LS1 L3 L1 YEL RELAY 2 HTR3 BLK 6 8 R1 BLK HTR1 BLK LS1 BLU 2 4 4 RELAY 1 BLK 2 RELAY 2 22 VDC COIL RELAY 1 22 VDC COIL BLU 11 11 9 9 BL U RECP SPT 7 7 3 3 TDR 2 2 FR BRN 4 0 6 2 8 4 C T1 R G 4 4 BRN NO 8 YEL CO M CAP COM HI MED LO BRN YEL BLK BLU BRN NC TDR PCB FR E VIO GRY W3 BLU WHT RED W2 RED-LOW 208V 230V C RED TRAN BRN FM BRN BRN T1 C BLK PCB GRN/YEL GND R GND W2 G WHT SEE NOTE #7 BARRIER SEE NOTE #6 INDOOR THERMOSTAT BLU-MED BLK-HI GRN/YEL-GND FM N O SPT BRN BRN YEL-COM CAP SEE NOTE #5 FAN MOTOR THERMALLY PROTECTED LEGEND OUTDOOR UNIT RED NOTES: 1. USE COPPER WIRE (75°C MIN) ONLY BETWEEN DISCONNECT SWITCH AND UNIT. 2. TO BE WIRED IN ACCORDANCE WITH NEC AND LOCAL CODES. 3. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. 4. REPLACE LOW VOLTAGE FUSE WITH NO GREATER THAN 5 AMP FUSE. 5. (3) SPEED MOTOR SHOWN. OPTIONAL (2) SPEED MOTOR USES HI (BLK) AND LOW (BLU OR RED). 6. CONNECT R TO R, G TO G, ETC., SEE OUTDOOR INSTRUCTION FOR DETAILS. 7. IF WIRE CRIMP IS REMOVED AN EMERGENCY HEAT RELAY IS REQUIRED. (SEE OUTDOOR-THERMOSTAT INSTRUCTIONS) F 0 1 F YEL 230 V RELAY 2 GRY RED G R 2 208 V BRN REC 6 1 6 1 BLK NC 6 1 REC RED VIO ORN BLK 24 V BLK BLU YEL RED RELAY 1 YEL PLUG R2 COM SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 15.2VA REMAINING VA AVAILABLE: 24.8VA RELAY 2 HTR2 BLK LS2 LS2 LS3 BLK BLK BLU YEL HTR2 L2 BLU LS3 HTR3 TRAN FIELD POWER WIRING CAP COM CAPACITOR COMMON F FM LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING PCB FAN RELAY EQUIPMENT GROUND FAN SPEED TAP LOCATION FR GND SPT R RELAY HTR LS HEATER LIMIT SWITCH MARKED TERMINAL PLUG & RECEPTACLE PCB PRINTED CIRCUIT BOARD REC RECTIFIER TDR TIME DELAY RECTIFIER TRAN TRANSFORMER UNMARKED TERMINAL MINIMUM CFM / MOTOR SPEED SELECTION 018 024 030 036 042 048 060 070 FAN COIL SIZE MOTOR SPEED AT 15 KW -- -- -- LO LO LO LO LO 324995-101 REV. A A00174 Fig. 9—Label Wiring 324995-101 —10— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE LEGEND SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 FIELD POWER WIRING COM F1 ICM DISCONNECT PER NEC GND L3 L1 FU GND HVTB HTR REC L2 BLU HTR3 BLK LS3 YEL RELAY 2 BLK BLK 6 8 COMMON LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING LINE FUSE EQUIPMENT GROUND HIGH VOLTAGE TERM BLOCK HEATER RECTIFIER FIELD POWER WIRING HTR1 BLK LS1 LIMIT SWITCH MARKED TERMINAL PLUG AND RECEPTACLE PCB PRINTED CIRCUIT BOARD TRAN TRANSFORMER RECP RECEPTACLE CB CIRCUIT BREAKER R RELAY TDR TIME DELAY RECTIFIER BLK BLU HTR2 BLK LS2 YEL LS RELAY 2 2 4 COOLING CONTROL ONLY BLU RELAY 1 BLK 2 4 L1 YEL RELAY 2 22 VDC COIL RELAY 1 22 VDC COIL SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 6.5VA REMAINING VA AVAILABLE: 33.5VA L2 BLK YEL BLK BLU FIELD POWER WIRING 9 11 208/240VAC 9 11 7 3 2 24VAC 3 2 7 6 1 6 1 TDR PLUG 2 4 24VAC RECP 2 4 COMPONENT ARRANGEMENT 3 3 2 2 BRN HTR1 4 PLUG 4 6 1 6 1 RED BRN YEL Com 208V BLK 230V PCB SEC1 AUX HEAT KW/CFM W 1 VIO F1 BRN AC/HP SIZE 12 9 8 7 VI RE BR OR O D N N 10 BLU 6 2 1 ORN BLK NOM G HI LO BLK YEL PLUG 3 O ON/OFF DELAY 0 30 0 90 90 0 HI C WHT 5 4 3 2 1 LO AUX1 HUM1 CONTINUOUS FAN MED HI BLK WHT VIO BLK BLU ORN BRN FU4 FU2 FU1 FU3 6 2 SEC1 SEC2 PCB D H 4 8 R 0 1 F1 REC W 1 W2 Y 1 Y/Y 2 G RELAY 2 6 2 8 4 O C 0 1 TDR PL1 HEATER / MOTOR 24 VAC 1 ICM GRY HEATER / MOTOR 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 230 V AUX 2 HUM2 YEL GND PL1 GRN WHT VIO ORN YEL RED GRY 208 V BRN YEL GRN/YEL PLUG 1 R2 RELAY 1 Y/Y 2 HP-EFF AC/HP CFM ADJUST BLK GR Y B W N EL LK HT 3 HP-COMFORT ORN WHT 5 4 AC L4 L2 L1 L3 L4 L3 L2 L1 CB2 CB1 60A 60A 60A 60A Y 1 SYSTEM TYPE 11 24 V R1 W 2 BLU GR Y VIO RED VIO R COM RED LS2 LS3 D H SEC2 KW CFM LS1 HTR2 RECP 2 BRN TRAN HTR3 TRAN 7 7 11 11 RED OUTDOOR UNIT 9 9 REC VIO ORN BLK BLU INDOOR THERMOSTAT YEL GND NOTES: 1. RECP 3 2. 3. 4. ICM RECP 4 GRY PLUG 4 5. 6. 7. 8. USE COPPER WIRE (75*C MIN) ONLY BETWEEN DISCONNECT SWITCH AND UNIT. TO BE WIRED IN ACCORDANCE WITH NEC AND LOCAL CODES. TRANSFORMER PRIMARY LEADS, BLUE 208V, RED 230V. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. REPLACE LOW VOLTAGE FUSE WITH NO GREATER THAN 5 AMP FUSE. DUAL CIRCUIT WIRING SHOWN. USE 60 AMP CLASS K FUSES ONLY, FOR REPLACEMENT. CONNECT R TO R, G TO G, ETC., SEE OUTDOOR INSTRUCTION FOR DETAILS. 325799-101 REV. B LABEL (2) SEE INSTRUCTION FOR INSTALLATION A00182 Fig. 10—Label Wiring 325799-101 —11— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT COMPONENT ARRANGEMENT FIELD POWER WIRING DISCONNECT PER NEC HVTB SEE RATING PLATEFOR VOLTS & HERTZ SEE NOTE #1 BLU L1 YEL L2 YEL LS6 YEL LS5 HTR5 BLK BLU LS4 HTR4 BLK YEL LS3 HTR3 BLU YEL LS2 HTR2 BLK 6 8 RELAY 3 4 2 8 6 L1 L2 L3 COM RED 4 2 BLK BLK 6 8 RELAY 1 LS1 HTR1 BLK BLK 2 4 11 11 RELAY 3 22 VDC COIL RED BRN BRN HI MED YEL BLK BLU LO RED G R NO F T1 C 208 V BRN TRAN FM GRN/YEL GND 2 NC 4 FR 0 RED-LOW BRN C F N O SPT TDR W2 W3 E GND SEE NOTE #5 R W2 G WHT SEE NOTE #8 BARRIER SEE NOTE #6 BRN INDOOR THERMOSTAT NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 0 1 GRY RED 230V RED C T1 R G PCB GRY CO M 4 6 4 4 VIO PCB 8 TDR RELAY 3 BRN NC YEL CAP COM 6 1 6 1 2 1 BRN GRY 6 8 BLK YEL 4 REC RELAY 2 BLK FR 8 230 V 0 RELAY 2 22 VDC COIL BLU SPT 2 2 WHT BL U 3 3 RED RECP 7 7 BRN 9 9 2 1 REC VIO ORN BLK 6 208 V BRN SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 15.2VA REMAINING VA AVAILABLE: 24.8VA RELAY 1 BLU TDR BLU HTR5 BLK RELAY 1 22 VDC COIL YEL LS 2 & 5 LS 4 & 3 24 V RELAY 2 HTR2 HTR3 HTR6 BLK BLU TDR PLUG HTR4 LS 1 & 6 L3 HTR6 BLU BLU HTR1 HVTB TRAN GND Use copper wire (75°C min) only between disconnect switch and unit. To be wired in accordance with N.E.C. and local codes. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire. Replace low voltage fuse with no greater than 5 amp fuse. (3) speed motor shown. optional (2) speed motor uses HI (BLK) and LOW (BLU or RED). Connect R to R, G to G, etc., see outdoor instruction for details. Largest heater shown, smaller heaters have fewer components. If wire crimp is removed an emergency heat relay is required. (See outdoor-thermostat instructions) OUTDOOR UNIT BLU-MED BLK-HI GRN/YEL-GND FM BRN BRN YEL-COM CAP FAN MOTOR THERMALLY PROTECTED LEGEND CAP COM CAPACITOR COMMON F FM LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING PCB FAN RELAY EQUIPMENT GROUND FAN SPEED TAP LOCATION H I VOLTAGE TERMINAL BLOCK FR GND SPT HVTB HTR LS HEATER LIMIT SWITCH MARKED TERMINAL PLUG & RECEPTACLE PCB PRINTED CIRCUIT BOARD REC RECTIFIER TDR TIME DELAY RECTIFIER TRAN TRANSFORMER UNMARKED TERMINAL MINIMUM CFM / MOTOR SPEED SELECTION FAN COIL SIZE 018 024 030 036 042 048 060 070 MOTOR SPEED AT 18 KW -- -- -- -- LO LO LO LO 324990-101 REV. A A00170 Fig. 11—Label Wiring 324990-101 —12— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE LEGEND SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT COM F1 ICM FIELD POWER WIRING DISCONNECT PER NEC HVTB SEE RATING PLATEFOR VOLTS & HERTZ SEE NOTE #1 BLU L1 L3 YEL LS6 HTR6 BLU YEL LS5 HTR5 BLK RELAY 3 BLK 2 4 YEL HTR4 BLK BLU LS4 FU GND HVTB HTR REC L2 YEL LS3 HTR3 BLU 8 FIELD POWER WIRING COOLING CONTROL ONLY BLK 6 RELAY 2 4 BLK BLU 6 8 RELAY 2 22 VDC COIL BLU 2 FIELD POWER WIRING L1 HTR2 BLK BLK 6 8 RELAY 1 LS1 HTR1 BLK BLK 2 4 BLU BLU YEL RELAY 1 22 VDC COIL REC VIO ORN BLK PLUG 9 9 TDR BLK 7 7 11 11 3 3 9 11 208/240VAC 9 11 RELAY 3 22 VDC COIL RED BRN TDR 2 2 6 1 6 1 7 3 2 24VAC 3 2 7 HTR1 4 4 HTR4 HTR3 LS 2 & 5 LS 4 & 3 LS 1 & 6 HTR6 BLK 230V AUX HEAT KW/CFM KW CFM W 1 VIO BRN 11 9 8 7 VI RE BR OR O D N N 10 BLU 6 2 1 ORN BLK NOM G HI LO BLK YEL PLUG 3 O 0 90 ON/OFF DELAY 30 0 90 0 LO CONTINUOUS FAN MED HI HI C WHT 5 4 3 2 1 AUX1 HUM1 BLK WHT VIO BLK BLU ORN BRN FU4 FU2 FU1 FU3 4 PCB D H R 0 F1 REC RELAY 2 6 2 8 4 Y 1 Y/Y 2 G O C TDR RELAY 3 6 2 8 4 W 1 W2 0 1 24 VAC 0 1 1 HEATER / MOTOR ICM REC GRY HEATER / MOTOR 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 8 PL1 GND PL1 GRN WHT VIO ORN YEL RED GRY 208 V 230 V AUX 2 HUM2 YEL PLUG 1 2 1 YEL GRN/YEL 6 SEC1 SEC2 Y/Y 2 HP-EFF AC/HP CFM ADJUST BLK GR Y B W N EL LK HT 3 HP-COMFORT ORN WHT 5 4 AC 24 V RELAY 1 Y 1 SYSTEM TYPE L4 L2 L1 L3 L4 L3 L2 L1 CB2 CB1 60A 60A 60A 60A W 2 BLU GR Y 12 RED VIO F1 AC/HP SIZE VIO R COM RED BRN HTR5 D H SEC2 OUTDOOR UNIT YEL Com 208V SEC1 INDOOR THERMOSTAT TRAN PCB N RED BRN 6 1 PLUG 2 4 24VAC RECP 2 4 HTR2 RECP 2 BRN 6 1 COMPONENT ARRANGEMENT BRN GRY SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 8.2VA REMAINING VA AVAILABLE: 31.8VA L2 YEL YEL LS2 LIMIT SWITCH MARKED TERMINAL PLUG AND RECEPTACLE PCB PRINTED CIRCUIT BOARD TRAN TRANSFORMER RECP RECEPTACLE CB CIRCUIT BREAKER R RELAY TDR TIME DELAY RECTIFIER TRA GND LS COMMON LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING LINE FUSE EQUIPMENT GROUND HIGH VOLTA GE TERM BLOCK HEATER RECTIFIER GND NOTES: 1. RECP 3 2. 3. 4. ICM RECP 4 GRY PLUG 4 5. 6. 7. 8. USE COPPER WIRE (75*C MIN) ONLY BETWEEN DISCONNECT SWITCH AND UNIT. TO BE WIRED IN ACCORDANCE WITH NEC AND LOCAL CODES. TRANSFORMER PRIMARY LEADS, BLUE 208V, RED 230V. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. REPLACE LOW VOLTAGE FUSE WITH NO GREATER THAN 5 AMP FUSE. DUAL CIRCUIT WIRING SHOWN. USE 60 AMP CLASS K FUSES ONLY, FOR REPLACEMENT. CONNECT R TO R, G TO G, ETC., SEE OUTDOOR INSTRUCTION FOR DETAILS. 325798-101 REV. B LABEL (2) SEE INSTRUCTION FOR INSTALLATION A00181 Fig. 12—Label Wiring 325798-101 —13— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE SCHEMATIC DIAGRAM COMPONENT ARRANGEMENT DISCONNECT PER NEC SEE RATING PLATE FOR VOLTS & HERTZ HTR1 SEE NOTE #1 L1 L3 L5 YEL L6 GND GND GND YEL FU5 YEL LS6 YEL FU3 YEL FU1 YEL LS5 HTR5 YEL LS4 HTR4 YEL LS3 HTR3 LS2 HTR2 YEL BLK BLK BLK BLK 4 2 8 6 4 RELAY 2 BLK 2 BLK YEL 4 2 BLU BLU YEL 11 11 9 9 BLU RECP 3 3 BLK BLK FU2 2 8 4 0 1 REC RELAY 2 RELAY 2 22 VDC COIL BLK 6 6 2 8 4 RELAY 3 22 VDC COIL RED BRN NO 2 2 BRN GRY 6 6 1 6 1 2 FR 0 1 BRN HI MED YEL BLK BLU LO RED RED-LOW E GND GRY VIO BLU RED W2 W3 WHT CO M SEE NOTE #6 208V 230V BLU-MED BLK-HI GRN/YEL-GND FM BRN BRN YEL-COM CAP FAN MOTOR THERMALLY PROTECTED LEGEND BRN RED TRAN FM GRN/YEL GND BRN C R W2 WHT G SEE NOTE #8 BARRIER SEE NOTE #7 INDOOR THERMOSTAT OUTDOOR UNIT CAP COM F FU FM FR NOTES: 1. 2. 3. 4. 5. 6. 7. 8. N O SPT TDR BRN BRN YEL CAP COM BLK PCB F NC PCB 4 F YEL 230 V C T1 R G GND 4 4 GRY RED T1 C 208 V BRN TDR RELAY 3 BRN FR FU5 FU3 FU1 FU6 FU4 FU2 0 1 TDR BLK G R L5 L3 L1 L6 L4 L2 RED 24 V TDR 8 NC SPT COM BLK 7 7 HTR5 SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 15.2VA REMAINING VA AVAILABLE: 24.8VA RELAY 1 BLK REC VIO ORN BLK HTR6 FU4 RELAY 1 22 VDC COIL PLUG BLK FU6 BLK 6 8 RELAY 1 LS 2 & 5 L2 BLK BLK LS1 HTR 1 YEL BLK 8 6 RELAY 3 HTR2 HTR3 LS 4 & 3 LS 1 & 6 L4 BLK HTR6 HTR4 TRAN FIELD POWER WIRING Use copper wire (75°C min) only between disconnect switch and unit. To be wired in accordance with N.E.C. and local codes. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire. Replace low voltage fuse with no greater than 5 amp fuse. Use 60 amp class K fuses only, for replacement. (3) speed motor shown. optional (2) speed motor uses HI (BLK) and LOW (BLU or RED). Connect R to R, G to G, etc., see outdoor instruction for details. If wire crimp is removed an emergency heat relay is required. 324994-101 REV. A (see outdoor-thermostat instructions) GND SPT CAPACITOR COMMON LOW VOLTAGE FUSE LINE FUSE FAN MOTOR FIELD POWER WIRING PCB FAN RELAY EQUIPMENT GROUND FAN SPEED TAP LOCATION HTR LS HEATER LIMIT SWITCH MARKED TERMINAL PLUG & RECEPTACLE PCB PRINTED CIRCUIT BOARD REC RECTIFIER TDR TIME DELAY RECTIFIER TRAN TRANSFORMER UNMARKED TERMINAL MINIMUM CFM / MOTOR SPEED SELECTION 018 024 030 036 042 048 060 070 FAN COIL SIZE MOTOR SPEED AT 24 KW -- -- -- -- -- LO LO LO MOTOR SPEED AT 30 KW -- -- ---- -- -- LO LO LO A00173 Fig. 13—Label Wiring 324994-101 —14— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE LEGEND 30KW 1PH SCHEMATIC DIAGRAM COM F1 ICM DISCONNECT PER NEC HVTB SEE RATING PLATE FOR VOLTS & HERTZ GND SEE NOTE #1 FU GND HVTB HTR REC L2 L1 YEL LS6 YEL FU5 HTR6 BLK BLK 8 6 RELAY 3 BLK 4 2 HTR5 BLK YEL LS5 YEL CB/FU3 YEL LS4 HTR4 BLK YEL LS3 HTR3 BLK YEL LS2 HTR2 BLK 9 7 7 11 11 3 3 2 2 4 PLUG 2 4 RECP 2 6 1 6 1 BLK 230V AUX HEAT KW/CFM KW CFM VIO F1 BRN AC/HP SIZE 12 9 8 7 BLU VI RE BR OR O D N N 10 6 2 1 ORN BLK HP-EFF NOM PLUG 3 LO G HI O ON/OFF DELAY 0 30 0 90 90 0 HI C WHT 5 4 3 2 1 LO AUX1 HUM1 CONTINUOUS FAN MED HI GND BLK WHT VIO BLK BLU ORN BRN COM RED 24 V 208 V BRN 230 V 2 PCB D H 4 R 0 1 F1 REC RELAY 2 6 2 8 4 W2 Y 1 Y/Y 2 G O 0 1 C TDR RELAY 3 6 2 8 4 W 1 0 1 24 VAC PL1 TDR HEATER / MOTOR ICM GND 1 GRY HEATER / MOTOR 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 8 AUX 2 HUM2 YEL PL1 GRN WHT VIO ORN YEL RED GRY 6 FU5 FU3 FU1 FU6 FU4 FU2 HTR5 YEL GRN/YEL PLUG 1 RELAY 1 Y/Y 2 BLK YEL BLK GR Y B W N EL LK HT 3 HP-COMFORT AC/HP CFM ADJUST WHT 5 4 AC ORN L5 L3 L1 L6 L4 L2 SEC1 SEC2 Y 1 SYSTEM TYPE 11 SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 8.2VA REMAINING VA AVAILABLE: 31.8VA W 2 BLU GR Y VIO RED VIO R W 1 LS 2 & 5 LS 4 & 3 HTR6 D H SEC2 HTR2 HTR3 L1 L2 L3 OUTDOOR UNIT YEL Com 208V 6 1 HTR4 HTR1 LS 1 & 6 BRN GRY PCB SEC1 PLUG 2 4 24VAC RECP 2 4 6 1 3 2 24VAC 3 2 7 HVTB RELAY 3 22 VDC COIL RED BRN TDR INDOOR THERMOSTAT RED BRN 7 COMPONENT ARRANGEMENT BRN TRAN LIMIT SWITCH MARKED TERMINAL PLUG AND RECEPTACLE PCB PRINTED CIRCUIT BOARD TRAN TRANSFORMER RECP RECEPTACLE CB CIRCUIT BREAKER TDR TIME DELAY RECTIFIER TDR REC VIO ORN BLK 11 208/240VAC 9 11 RELAY 2 22 VDC COIL LS COOLING CONTROL ONLY BLK BLK 6 8 CB/FU2 RELAY 1 BLK 4 2 RELAY 1 BLU 22 VDC COIL BLK BLU 9 9 FIELD POWER WIRING YEL LS1 HTR1 BLK YEL YEL BLK BLK BLK 8 6 CB/FU4 RELAY 2 BLK 4 2 YEL CB/FU1 FU6 COMMON LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING LINE FUSE EQUIPMENT GROUND HIGH VOLTAGE TERM BLOCK HEATER RECTIFIER TRAN FIELD POWER WIRING NOTES: 1. USE COPPER WIRE (75°C MIN) ONLY BETWEEN DISCONNECT SWITCH AND UNIT. TO BE WIRED IN ACCORDANCE WITH NEC AND LOCAL CODES. TRANSFORMER PRIMARY LEADS, BLUE 208V, RED 230V. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. 5. REPLACE LOW VOLTAGE FUSE WITH NO GREATER THAN 5 AMP FUSE. 6. 20KW HEATER USES ONE DOUBLE POLE LS ON MIDDLE TOP ELEMENT. 7. 18, 24 AND 30KW HEATERS USE DOUBLE POLE LIMIT SWITCHES. 8. LARGEST HEATERS ARE SHOWN, SMALLER HEATERS WILL HAVE FEWER ELEMENTS AND COMPONENTS. 9. 1 PHASE HEATERS ARE SHOWN WIRED FOR SINGLE SUPPLY CIRCUIT. 10. USE 60 AMP CLASS K FUSES ONLY, FOR REPLACEMENT. 11. CONNECT R TO R, G TO G, ETC., SEE OUTDOOR INSTRUCTION FOR DETAILS. 2. 3. 4. RECP 3 ICM RECP 4 GRY PLUG 4 324985-101 REV. C LABEL (2) A00166 Fig. 14—Label Wiring 324985-101 —15— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT GND COMPONENT ARRANGEMENT DISCONNECT PER NEC SEE RATING PLATE FOR VOLTS & HERTZ HTR1 SEE NOTE #1 YEL L1 YEL LS6 FU5 YEL FU3 YEL (1 PHASE) YEL YEL YEL HTR6 BLK LS5 HTR5 BLK LS4 HTR4 BLK LS3 HTR3 BLK LS2 BLK 6 8 RELAY 3 BLK 8 6 RELAY 2 4 HTR2 BLK BLK 6 8 FU1 HTR6 HTR5 FU6 COM SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 15.2VA REMAINING VA AVAILABLE: 24.8VA BLK FU4 RELAY 1 BLK FU2 6 2 8 4 0 1 REC RELAY 1 BLK YEL LS1 HTR1 BLK 4 2 RED 24 V BLK 2 LS 2 & 5 L2 BLK (1 PHASE) 2 4 HTR2 HTR3 LS 4 & 3 LS 1 & 6 BLK L3 HTR4 RELAY 2 22 VDC COIL TRAN FIELD POWER WIRING HVTB L5 L3 L1 L6 L4 L2 FU5 FU3 FU1 FU6 FU4 FU2 208 V BRN 230 V RELAY 2 2 6 TDR BLK 11 11 YEL CAP COM HI MED LO BRN YEL BLK BLU CO M FM BRN RED GRN/YEL GND BRN W2 W3 GND E R W2 WHT G SEE NOTE #8 BARRIER SEE NOTE #7 INDOOR THERMOSTAT OUTDOOR UNIT RED SEE NOTE #6 RED-LOW BLU-MED BLK-HI GRN/YEL-GND FM BRN BRN YEL-COM CAP FAN MOTOR THERMALLY PROTECTED CAP COM F FU FM FR GND SPT NOTES: 1. 2. 3. 4. 5. 6. 7. 8. GND LEGEND C TRAN N O SPT FR 0 1 208V 230V BRN 4 8 TDR VIO BLK YEL NC PCB F T1 C F 2 6 GRY RED G R FR PCB RELAY 3 BRN NO C T1 R G 0 TDR 4 4 6 1 6 1 BLK NC SPT 2 2 BLU BLU RECP 3 3 7 7 WHT 9 9 4 8 1 GRY BLU BR N RED YEL PLUG RELAY 3 RELAY 1 22 VDC COIL 22 VDC COIL RED BRN TDR REC BRN GRY VIO ORN Use copper wire (75°C min) only between disconnect switch and unit. To be wired in accordance with N.E.C. and local codes. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire. Replace low voltage fuse with no greater than 5 amp fuse. Use 60 amp class K fuses only, for replacement. (3) speed motor shown. optional (2) speed motor uses HI (BLK) and LOW (BLU or RED). Connect R to R, G to G, etc., see outdoor instruction for details. If wire crimp is removed an emergency heat relay is required. (see outdoor-thermostat instructions) HVTB CAPACITOR COMMON LOW VOLTAGE FUSE LINE FUSE FAN MOTOR FIELD POWER WIRING PCB FAN RELAY EQUIPMENT GROUND FAN SPEED TAP LOCATION H I VOLTAGE TERMINAL BLOCK HTR LS HEATER LIMIT SWITCH MARKED TERMINAL PLUG & RECEPTACLE PCB PRINTED CIRCUIT BOARD REC RECTIFIER TDR TIME DELAY RECTIFIER TRAN TRANSFORMER UNMARKED TERMINAL MINIMUM CFM / MOTOR SPEED SELECTION FAN COIL SIZE 018 024 030 036 042 048 060 070 MOTOR SPEED AT 24 KW -- -- -- -- -- LO LO LO MOTOR SPEED AT 30 KW -- -- -- -- -- LO LO LO 324993-101 REV. A A00172 Fig. 15—Label Wiring 324993-101 —16— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATI ONS DE PLUS DE 150 V A LA TERRE LEGEND SCHEMATIC DIAGRAM SINGLE SUPPLY CIRCUIT GND L3 YEL LS6 FU5 YEL HTR6 BLK 6 8 BLK FU6 LS4 HTR4 BLK YEL LS3 HTR3 BLK YEL LS2 HTR2 BLK 8 6 RELAY 2 4 2 BLK YEL BLU 3 3 2 2 6 1 6 1 HVTB AUX HEAT KW/CFM VIO BRN 11 9 8 7 BLU VI RE BR OR O D N N 10 6 2 1 ORN BLK HP-EFF NOM PLUG 3 LO G HI O ON/OFF DELAY 0 30 0 90 90 0 HI C WHT 5 4 3 2 1 LO AUX1 HUM1 CONTINUOUS FAN MED HI GND BLK WHT VIO BLK BLU ORN BRN COM RED 24 V 208 V BRN 230 V 2 PCB D H 4 R 0 1 F1 REC RELAY 2 6 2 8 4 Y 1 Y/Y 2 G O C TDR RELAY 3 6 2 8 4 W 1 W2 0 1 PL1 0 1 24 VAC TDR HEATER / MOTOR ICM GND 1 GRY HEATER / MOTOR 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 8 AUX 2 HUM2 YEL PL1 GRN WHT VIO ORN YEL RED GRY 6 FU5 FU3 FU1 FU6 FU4 FU2 HTR5 YEL GRN/YEL PLUG 1 RELAY 1 Y/Y 2 BLK YEL BLK GR Y B W N EL LK HT 3 HP-COMFORT AC/HP CFM ADJUST WHT 5 4 AC ORN L5 L3 L1 L6 L4 L2 SEC1 SEC2 Y 1 SYSTEM TYPE LS 2 & 5 LS 4 & 3 SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 8.2VA REMAINING VA AVAILABLE: 31.8VA W 2 BLU GR Y 12 RED VIO F1 AC/HP SIZE VIO R W 1 HTR2 HTR3 HTR6 D H SEC2 KW CFM PLUG 2 4 24VAC RECP 2 4 L1 L2 L3 OUTDOOR UNIT BLK 230V 6 1 HTR4 HTR1 LS 1 & 6 INDOOR THERMOSTAT YEL Com 208V PCB SEC1 7 4 4 N RED BRN 6 1 3 2 24VAC 3 2 TDR BRN TRAN LIMIT SWITCH MARKED TERMINAL PLUG AND RECEPTACLE PCB PRINTED CIRCUIT BOARD TRAN TRANSFORMER RECP RECEPTACLE CB CIRCUIT BREAKER TDR TIME DELAY RECTIFIER COMPONENT ARRANGEMENT RELAY 3 RELAY 1 22 VDC COIL 22 VDC COIL RED BRN TDR REC BRN GRY VIO ORN 7 7 7 BLK FU2 6 BLK 11 11 9 RECP 2 9 11 208/240VAC 9 11 RELAY 2 22 VDC COIL LS COOLING CONTROL ONLY 9 BLK RELAY 1 BLK YEL LS1 HTR1 BLK 4 2 COMMON LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING LINE FUSE EQUIPMENT GROUND HIGH VOLTAGE TERM BLOCK HEATER RECTIFIER FIELD POWER WIRING BLK FU4 BLK 8 FU1 PLUG 2 FU GND HVTB HTR REC L2 LS5 YEL (1 PHASE) BLK HTR5 BLK RELAY 3 BLK (1 PHASE) 2 4 YEL FU3 COM F1 ICM SEE NOTE #1 YEL L1 DISCONNECT PER NEC TRA SEE RATING PLATE FOR VOLTS & HERTZ FIELD POWER WIRING HVTB NOTES: 1. RECP 3 ICM RECP 4 GRY PLUG 4 USE COPPER WIRE (75°C MIN) ONLY BETWEEN DISCONNECT SWITCH AND UNIT. 2. TO BE WIRED IN ACCORDANCE WITH NEC AND LOCAL CODES. 3. TRANSFORMER PRIMARY LEADS, BLUE 208V, RED 230V. 4. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. 5. REPLACE LOW VOLTAGE FUSE WITH NO GREATER THAN 5 AMP FUSE. 6. 20KW HEATER USES ONE DOUBLE POLE LS ON MIDDLE TOP ELEMENT. 7. 18, 24 AND 30KW HEATERS USE DOUBLE POLE LIMIT SWITCHES. 8. LARGEST HEATERS ARE SHOWN, SMALLER HEATERS WILL HAVE FEWER ELEMENTS AND COMPONENTS. 9. 1 PHASE HEATERS ARE SHOWN WIRED FOR SINGLE SUPPLY CIRCUIT. 10. USE 60 AMP CLASS K FUSES ONLY, FOR REPLACEMENT. 11. CONNECT R TO R, G TO G, ETC., SEE OUTDOOR INSTRUCTION FOR DETAILS. 326114-101 REV. B LABEL (2) 3 PHASE A00185 Fig. 16—Label Wiring 326114-101 —17— SCHEMATIC DIAGRAM CAUTION: NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND SEE RATING PLATE FOR VOLTS & HERTZ ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE FIELD POWER WIRING COOLING CONTROLS ELECTRIC HEAT L2 L2 LS LS DISC GND SEE NOTE #8 DISC SEE NOTE #1 DISCONNECT PER NEC DISC L1 DISC SEE NOTE #8 L1 COMPONENT ARRANGEMENT HTR HTR SYSTEM TRANSFORMER 40.0 VA FAN COIL/HEATER: 8.4 VA REMAINING VA AVAILABLE: 31.6VA COM YEL YEL LS2 YEL HTR2 BLU BLU BLK RELAY 1 4 NO F T1 C 208V 230V BRN C T1 R G REC RELAY 1 22 VDC COIL L2 L1 DISC 60A 60A BLK G R RED 24V 1 2 PC8 GND ORN NC PCB 6 REC BLK YEL BLK 8 BLK BLK FR YEL BLK HTR1 BLK LS1 YEL SPT RELAY 1 6 8 2 4 BLK TRAN SEE NOTE #6 NC NO FR SPT VIO RED- LOW FM GRY RED BLK-HI GND ORN F GRY GRN/YEL-GND BRN BRN CAP YEL-COM SEE NOTE #5 YEL VIO BRN FAN MOTOR THERMALLY PROTECTED CAP COM 208V 230V LEGEND COM R G W BRN BRN C CAP CAPACITOR COM COMMON RED YEL DISC DISCONNECT HI BLK BARRIER SEE NOTE#7 TRAN FM F FUSE BRN GRN/YEL FM FAN MOTOR INDOOR OUTDOOR LO RED GND THERMOSTAT UNIT FIELD POWER WIRING NOTES FR PCB FAN RELAY GND EQUIPMENT GROUND 1. Use copper wire (75oc min) only between disconnect switch and unit HTR HEATER 2. To be wired in accordance with nec and local codes. LS LIMIT SWITCH 3. If any of the original wire, as supplied, must be replaced, use the same MARKED TERMINAL or equivalent type wire. PLUG AND RECEPTACLE 4. Replace low voltage fuse with no greater than 5 AMP fuse. PCB PRINTED CIRCUIT BOARD 5. (2) Speed Motor uses HI (BLK) and LOW (RED). 6. Smaller heaters will have fewer components. REC RECTIFIER 7. Connect R to R, G to G, etc.., see outdoor instructions for details. SPT FAN SPEED TAP LOCATION 8. Cooling controls wiring not used with electric heaters. TRAN TRANSFORMER UNMARKED TERMIINAL RED This compartment must be closed except when servicing ROTATION 324494-101 REV.A MINIMUM MOTOR SPEED SELECTION FAN COIL SIZE 018 024 030 MOTOR SPEED ONE HTR LO LO LO MOTOR SPEED TWO HTR LO LO LO A00163 Fig. 17—Label Wiring 324994-101 —18— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE SCHEMATIC DIAGRAM HTR3 BLK LS2 HTR2 BLK RELAY 2 6 8 LS1 HTR1 COM SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 19.0VA REMAINING VA AVAILABLE: 21.0VA BLK RELAY 2 BLK YEL ORG RELAY 1 PCB LED 3 2 1 6 5 4 9 8 7 DUMMY T2 240 VAC T3 LO 5 4 9 8 7 T3 F RED BRN BLK COM HI MED BRN F1 HI F2 LO O W2D G Y C SEC 2 SEC 1 R Y TRAN BRN SEE NOTE #3 GRN/YEL GND GND Y G O CAP COMM F FW GND HPLV HTR LS E W2 MINIMUM MOTOR LO SPEED TAP SELECTION FAN COIL SIZE 018-240V018-208V 024 030 033 MOTOR SPEED AT 10 KW MED HI LO LO LO CAPACITOR COMMON LOW VOLT FUSE FAN MOTOR EQUIPMENT GROUND HEAT PUMP LOW VOLT HEATER LIMIT SWITCH 324986-101 REV. A TRAN 4 8 4 FM BRN BRN YEL-COM STEADY LIGHT LED LVTB R TRAN XFORM 0 1 0 C STEADY FLASH 1 FLASH DIAGNOSTIC LIGHT LOW VOLT TERM BRD RELAY TRANSFORMER PCB TRAN TERMINALS FIELD HIGH VOLTAGE FIELD LOW VOLTAGE HPLV LEADS MARKED TERMINAL 036 LO 8 NO LIGHT OR FLASH LEGEND Use copper wire (75°C min) only between disconnect switch and unit. Connect low voltage wiring as shown (24VAC). Connect transformer primary to the proper voltage terminal To be wired in accordance with N.E.C. and local codes. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire. 6. Replace low voltage fuse with no greater than 5 amp fuse. 7. Refer to thermostat instructions for "E" jumper installation. 8. Do NOT connect thermostat "E" to PCB "W3". 2 R SEE NOTES #2,#7, AND #8 NOTES: 6 CAP LED FLASH CODES INDOOR THERMOSTAT LO 2 1 BLU-MED BLK-HI GRN/YEL-GND O C RELAY 2 6 FAN MOTOR THERMALLY PROTECTED W2 R FM 230 V RELAY 1 RED-LOW HPLV LEADS RED CAP 208 V T2 JW1 BLK BLU 24 V GND AUX + T1 COM 208V 230V YEL 1. 2. 3. 4. 5. 6 YEL YEL F2 BLK 1 Yo FAN 240 DUMMY VAC 2 LVTB HI 3 W3 COMM AUX - PCB W2T F1 R C Y G O W2D W2T W3 Yo SEC 2 BRN RED BRN SEC 1 F RED XFORM T1 R2 JW1 YEL R1 BLK 4 2 LS2 L2 RELAY 2 BLK HTR2 LS3 JW2 YEL LS3 BLK BLK VIO YEL HTR3 LS1 RELAY 1 4 2 BRN YEL YEL HTR1 SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 GND L1 COMPONENT ARRANGEMENT DISCONNECT PER NEC FIELD POWER WIRING PCB JUMPER (JW) UNMARKED TERMINAL 2 FLASHES 3 FLASHES 4 FLASHES NO POWER OR BOARD FAILURE BOARD FAILURE STAND BY CONDITION OR FAN ONLY HEAT PUMP HEAT ONLY OPERATING HEAT PUMP PLUS 1 RELAY HEAT PUMP PLUS 2 RELAYS HEAT PUMP PLUS 3 RELAYS 5 FLASHES COOL MODE 6 FLASHES DEFROST MODE 7 FLASHES EMERGENCY HEAT MODE A00167 Fig. 18—Label Wiring 324986-101 —19— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE COMPONENT ARRANGEMENT SCHEMATIC DIAGRAM DISCONNECT PER NEC 2 HTR3 4 HTR2 LS2 YEL BLK RELAY 1 2 4 BLK BLK RELAY 3 RELAY 2 BLK BLK 4 2 YEL BLK RED RELAY 1 4 8 7 T3 Yo LVTB W3 W2T O Y G C R COM 208V 230V CAP RED BLK BRN COM HI MED BRN GRN/YEL GND F2 LO 4 GND 208 V 0 6 2 8 4 0 6 2 8 4 L4 FU4 30A L2 FU2 60A L1 FU1 60A FM BLU-MED BLK-HI GRN/YEL-GND L3 FU3 30A 0 1 RED-LOW BRN BRN YEL-COM CAP FAN MOTOR THERMALLY PROTECTED O LED FLASH CODES R C Y G O E W2 NO LIGHT OR FLASH C STEADY LIGHT INDOOR THERMOSTAT STEADY FLASH SEE NOTES #2,#7, AND #8 LO LEGEND NOTES: 1. 2. 3. 4. 5. 8 RELAY 1 HI W2 RED TRAN BRN SEE NOTE #3 2 1 F1 HPLV LEADS Y R FM 24 V BRN RELAY 2 GND YEL BLU T2 BRN YEL F 6 1 AUX + T1 JW1 BLK F2 5 9 SEC 2 YEL LO 240 VAC T3 1 2 6 DUMMY T2 FAN 240 DUMMY VAC BRN 3 W2D HI PCB SEC 1 COMM RELAY 2 VIO XFORM T1 RED 230 V R SEC 1 F C Y SEC 2 G LED O W2D W2T 3 2 1 W3 6 5 4 Yo 9 8 7 AUX - ORG F1 COM PCB BRN HTR1 LS1 YEL R1 R2 RELAY 3 BLK 8 6 R3 SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 26.3VA REMAINING VA AVAILABLE: 13.7VA BLK RELAY 2 LS2 LS3/4 TRAN LS3 HTR2 HTR4 3 1 YEL RELAY 3 BLK 2 4 LS1 JW1 HTR4 L4 HTR3 JW2 LS4 L2 FU4 FU1 YEL YEL GND HTR1 BLK L1 SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 FU2 L3 FU3 FIELD POWER WIRING Use copper wire (75°C min) only between disconnect switch and unit. Connect low voltage wiring as shown (24VAC). Connect transformer primary to the proper voltage terminal To be wired in accordance with N.E.C. and local codes. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire. 6. Replace low voltage fuse with no greater than 5 amp fuse. 7. Refer to thermostat instructions for "E" jumper installation. 8. Do NOT connect thermostat "E" to PCB "W3". CAP COMM F FW GND HPLV HTR LS MINIMUM MOTOR LO SPEED TAP SELECTION FAN COIL SIZE 018 024 030 033 036 038 042 048 MOTOR SPEED AT 15 KW -- MED LO LO LO LO LO LO CAPACITOR COMMON LOW VOLT FUSE FAN MOTOR EQUIPMENT GROUND HEAT PUMP LOW VOLT HEATER LIMIT SWITCH LED LVTB TRAN XFORM 1 FLASH DIAGNOSTIC LIGHT LOW VOLT TERM BRD 2 FLASHES TRANSFORMER PCB TRAN TERMINALS 3 FLASHES FIELD HIGH VOLTAGE 4 FLASHES FIELD LOW VOLTAGE 5 FLASHES HPLV LEADS MARKED TERMINAL 324989-101 REV. B 6 FLASHES PCB JUMPER (JW) UNMARKED TERMINAL 7 FLASHES NO POWER OR BOARD FAILURE BOARD FAILURE STAND BY CONDITION OR FAN ONLY HEAT PUMP HEAT ONLY OPERATING HEAT PUMP PLUS 1 RELAY HEAT PUMP PLUS 2 RELAYS HEAT PUMP PLUS 3 RELAYS COOL MODE DEFROST MODE EMERGENCY HEAT MODE A00169 Fig. 19—Label Wiring 324989-101 —20— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE SCHEMATIC DIAGRAM COMPONENT ARRANGEMENT YEL LS3 2 BLK HTR3 BLK RELAY 1 4 2 4 BLK HTR4 BLK HTR2 LS2 BLK RELAY 2 BLK RELAY 2 HTR1 BLK LS1 PCB RELAY 3 BLK 4 2 YEL YEL SEC 2 LED RELAY 2 3 2 1 6 5 4 9 8 7 BRN VIO BLK DUMMY T2 5 RED 7 RED BLK BRN COM HI MED GRN/YEL GND Yo LVTB W3 W2T Y G 8 4 208 V 0 RELAY 2 6 2 8 4 L4 FU4 60A 0 1 HI F2 LO 6 L2 FU2 60A 8 GND RED-LOW BLU-MED BLK-HI GRN/YEL-GND 4 0 1 HPLV LEADS L1 FU1 60A 2 L3 FU3 60A GND RED TRAN BRN SEE NOTE #3 FM BRN BRN YEL-COM CAP FAN MOTOR THERMALLY PROTECTED O LED FLASH CODES R C Y G O SEE NOTES #2, #7,AND #8 LEGEND NOTES: Use copper wire (75°C min) only between disconnect switch and unit. Connect low voltage wiring as shown (24VAC). Connect transformer primary to the proper voltage terminal To be wired in accordance with N.E.C. and local codes. If any of the original wire, as supplied, must be replaced, use the same or equivalent type wire. 6. Replace low voltage fuse with no greater than 5 amp fuse. 7. Refer to thermostat instructions for "E" jumper installation. 8. Do NOT connect thermostat "E" to PCB "W3". CAP COMM F FW GND HPLV HTR LS MINIMUM MOTOR LO SPEED TAP SELECTION 030 033 036 038 042 048 060 070 FAN COIL SIZE MOTOR SPEED AT 20 KW MED MED LO LO LO LO LO LO NO LIGHT OR FLASH NO POWER OR BOARD FAILURE STEADY LIGHT BOARD FAILURE C E W2 INDOOR THERMOSTAT LO 1. 2. 3. 4. 5. T3 Y R FM 2 1 F1 W2 BRN 24 V BRN RELAY 1 JW1 COM 208V 230V CAP 6 T2 BRN YEL BLU RED 230 V AUX + T1 RELAY 1 4 8 YEL C BLK 6 AUX - F R YEL LO F2 1 2 9 240 VAC T3 SEC 2 FAN 240 DUMMY VAC 3 W2D HI SEC 1 COMM PCB O XFORM T1 R C Y G O W2D W2T W3 Yo SEC 1 F ORG F1 COM SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 26.3VA REMAINING VA AVAILABLE: 13.7VA RELAY 3 8 6 LS2 LS3/4 HTR4 RELAY 3 2 4 3 LS1 HTR2 TRAN YEL LS4 1 L2 HTR3 JW2 JW1 FU3 YEL YEL L4 BRN FU1 GND FU2 L3 HTR1 BLK L1 SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 FU4 DISCONNECT PER NEC FIELD POWER WIRING CAPACITOR COMMON LOW VOLT FUSE FAN MOTOR EQUIPMENT GROUND HEAT PUMP LOW VOLT HEATER LIMIT SWITCH LED LVTB TRAN XFORM STEADY FLASH 1 FLASH DIAGNOSTIC LIGHT 2 FLASHES LOW VOLT TERM BRD TRANSFORMER 3 FLASHES PCB TRAN TERMINALS FIELD HIGH VOLTAGE 4 FLASHES FIELD LOW VOLTAGE 5 FLASHES HPLV LEADS MARKED TERMINAL 324991-101 REV. A COOL MODE 6 FLASHES DEFROST MODE 7 FLASHES EMERGENCY HEAT MODE PCB JUMPER (JW) UNMARKED TERMINAL STAND BY CONDITION OR FAN ONLY HEAT PUMP HEAT ONLY OPERATING HEAT PUMP PLUS 1 RELAY HEAT PUMP PLUS 2 RELAYS HEAT PUMP PLUS 3 RELAYS A00171 Fig. 20—Label Wiring 324991-101 —21— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE SCHEMATIC DIAGRAM COMPONENT ARRANGEMENT DISCONNECT PER NEC SEE RATING PLATE FOR VOLTS & HERTZ GND L1 COM SEE NOTE #1 RED 24 V L2 208 V 230 V BRN BLK YEL TRAN FIELD POWER WIRING SYSTEM TRANSFORMER: 40.0VA FAN COIL/HEATER: 5.0VA REMAINING VA AVAILABLE: 35.0VA YEL 208V 230V C R BRN HI MED YEL BLK BLU LO RED BRN RED TRAN FM GRN/YEL GND BRN W2 WHT SPT GRY BRN E CO M BLK NO FR VIO PCB YEL CAP GRY RED G R F T1 C W3 FR YEL NO F NC PCB BLU NC 4 4 BRN RED SPT BRN RECP 6 1 6 1 3 2 3 2 11 7 11 7 BLU BLK W2 9 9 WHT PLUG COM C T1 R G BLK G BARRIER SEE NOTE #6 INDOOR THERMOSTAT OUTDOOR UNIT GND RED-LOW BLU-MED BLK-HI GRN/YEL-GND FM CAP BRN BRN YEL-COM SEE NOTE #5 FAN MOTOR THERMALLY PROTECTED LEGEND NOTES: 1. USE COPPER WIRE (75°C MIN.) ONLY BETWEEN DISCONNECT SWITCH AND UNIT. 2. TO BE WIRED IN ACCORDANCE WITH NEC AND LOCAL CODES. 3. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. 4. REPLACE LOW VOLTAGE FUSE WITH NO GREATER THAN 5 AMP FUSE. 5. (3) SPEED MOTOR SHOWN. OPTIONAL (2) SPEED MOTOR USES HI (BLK) AND LOW (BLU OR RED). 6. CONNECT R TO R, G TO G, ETC., SEE OUTDOOR INSTRUCTION FOR DETAILS. CAP COM F FM CAPACITOR COMMON LOW VOLTAGE FUSE FAN MOTOR FIELD POWER WIRING FR PCB FAN RELAY FU LINE FUSE GND EQUIPMENT GROUND SPT FAN SPEED TAP LOCATION HEATER LIMIT SWITCH MARKED TERMINAL PLUG AND RECEPTACLE PCB PRINTED CIRCUIT BOARD SEQ SEQUENCER TRAN TRANSFORMER UNMARKED TERMINAL HTR LS 321210-101 REV. G A00162 Fig. 21—Label Wiring 321210-101 —22— CAUTION: THIS COMPARTMENT MUST BE CLOSED EXCEPT FOR SERVICING NOT SUITABLE FOR USE ON SYSTEMS EXCEEDING 150V TO GROUND BLOWER MOTOR ROTATION ATTENTION: NE CONVIENT PAS AUX INSTALLATIONS DE PLUS DE 150 V A LA TERRE LEGEND 20KW 1PH SCHEMATIC DIAGRAM DISCONNECT PER NEC FIELD POWER WIRING SEE RATING PLATE FOR VOLTS & HERTZ SEE NOTE #1 L1 L2 GND YEL CB COM F1 FU GND BLK PLUG 2 9 11 7 3 2 6 1 4 9 11 7 3 2 6 1 4 HTR FIELD POWER WIRING MARKED TERMINAL PLUG AND RECEPTACLE CIRCUIT BREAKER COMMON LOW VOLTAGE FUSE LINE FUSE EQUIPMENT GROUND HEATER HVTB ICM LS PCB R REC RECP TDR TRAN HIGH VOLTAGE TERM BLOCK FAN MOTOR LIMIT SWITCH PRINTED CIRCUIT BOARD RELAY RECTIFIER RECEPTACLE TIME DELAY RECTIFIER TRANSFORMER RECP 2 BRN COMPONENT ARRANGEMENT SEC1 SEC2 BLK Com 208V AUX HEAT KW/CFM KW CFM W 1 VIO 230V F1 BRN AC/HP SIZE 12 9 8 7 BLU VI RE BR OR O D N N 10 6 2 1 NOM PLUG 3 LO HI O ON/OFF DELAY 0 30 0 90 90 0 HI C WHT 5 4 3 2 1 LO CONTINUOUS FAN MED HI AUX1 HUM1 BLK WHT VIO BLK BLU ORN BRN COM RED 24 V BRN ICM 208 V 230 V GND 24 VAC 1 GRY HEATER / MOTOR 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 HEATER / MOTOR AUX 2 HUM2 YEL GND PL1 GRN WHT VIO ORN YEL RED GRY C YEL GRN/YEL PLUG 1 O PL1 G BLK YEL Y 1 Y/Y 2 G Y/Y 2 HP-EFF AC/HP CFM ADJUST ORN BLK BLK GR Y B W N EL LK HT 3 HP-COMFORT ORN WHT 5 4 AC W 1 W2 Y 1 SYSTEM TYPE 11 F1 W 2 BLU GR Y VIO RED VIO R D H R D H SEC2 TRAN SEC1 PCB OUTDOOR UNIT YEL PCB INDOOR THERMOSTAT RED TRAN BRN NOTES: 1. RECP 3 2. ICM 3. 4. RECP 4 GRY 5. PLUG 4 6. 7. 8. 326014-101 REV. B USE COPPER WIRE (75*C MIN) ONLY BETWEEN DISCONNECT SWITCH AND UNIT. TO BE WIRED IN ACCORDANCE WITH NEC AND LOCAL CODES. TRANSFORMER PRIMARY LEADS, BLUE 208V, RED 230V. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT TYPE WIRE. REPLACE LOW VOLTAGE FUSE WITH NO GREATER THAN 5 AMP FUSE. DUAL CIRCUIT WIRING SHOWN. USE 60 AMP CLASS K FUSES ONLY, FOR REPLACEMENT. CONNECT R TO R, G TO G, ETC., SEE OUTDOOR INSTRUCTION FOR DETAILS. A00184 Fig. 22—Label Wiring 326014-101 —23— © 2001 Payne Heating & Cooling P.O. Box 70, Indianapolis, IN 46206 —24— wdpf1m01 Catalog No. 53PF-1M2