CN.D Series Industrial Power for Business-Critical Continuity™ DC Energy - Charger CN.D chargers are designed to charge 12 V to 48 Vdc battery or maintain larger battery used for Genset starter or fire pumps Self. Benefits A robust charger batteries unit, adapted to the difficult industrial environments, supplemented effective protections increase its reliability. n Charger units for integration in cabinet providing performances and data with high quality level (regulation, reliability, short circuit proof…). n A clear indication two LED report mains presence and indicate charging operation. As an option three indicators and two relay report alarm and a good accessibility give fast maintenance. n Small overall dimensions facilitate its integration. n Second voltage (Egalization mode) for electrolytic cells batteries (Lead-acid and NiCad). n They can also be integrated in box to provide power supplies with backup for process control systems, or to LV/MV switchgears. CN.D Series Industrial Power for Business-Critical Continuity™ DC Energy - Charger Nominal Nominal voltage (V) current (A) 1000027 CN.D 12-12 12 12 1011861 CN.D 08-24 24 8 1000029 CN.D 10-24 24 10 1011719 CN.D 12-24 24 12 1000030 CN.D 15-24* 24 15 1000035 CN.D 05-48 48 5 * Input single-voltage : 230 V (on request: 400 V) Code Reference Input power (VA) 330 405 485 600 750 485 Protection Weight Input Output (Kg) 2 20 5.0 2 16 5.0 2 20 5.2 4 20 6.8 4 25 6.8 2 10 5.2 This publication is issued to provide outline information only and is not deemed to form any part of any offer and/or contract. The company has a policy of continuous product development and improvement, and we therefore reserve the right to vary any information without prior notice. Technical Specification Dimensions HxWxD 140x150x157 140x150x157 140x150x157 140x150x175 140x150x175 140x150x157 General data Mains inputs voltage 230 - 400 VAC single phase -10% +15% - 50 Hz & -10% +25% - 60 Hz Static regulation ± 1% Short circuit current limitation from 0.75 x In to In Filtering < 6% battery disconnected Ambient operating temperature / Storage -5° to +50 °C / -40° à +50°C Relative humidity < 95% with 20°C («all climates») LED signals « Mains » and « Egalization mode » on For futher details please refer to technical data sheet Options Reference Designation 4 Manual charge (equilizing) : jumper on 2 terminals E Manual charge (equilizing) with led signaling controlled by switch + adjusting potentiometer mD Alarm card, allowing to detect : • Battery low voltage with 10 sec timer. LED + voltage free contact • A real charger failure combinig a low dc volt alarm enslaving to mains availability and a high dc volt alarm. LED + volt free contact Other Input voltage / output voltage / rating Specific version - Parallel operation - Casing fitting Standards Compliance Emerson Network Power. The global leader in enabling Business-Critical Continuity™. ECM n°2004/108/CE - NF EN 61000-6-2 / NF EN 61000-6-4 LV n°2006/95/CE - NF EN 60439-1 Transformers comply to NF EN 61558-2-6 n AC Power n Connectivity n DC Power n Embedded Computing Emerson Network Power IS SAS 30 avenue Montgolfier - BP90 - 69684 Chassieu Cedex France T +33 (0) 4 72 47 63 77 - F +33 (0) 4 78 40 13 94 E aees@emerson.com / www.aees.fr EmersonNetworkPower.com n Embedded Power n Industrial Power n Infrastructure Management & Monitoring n Outside Plant n Power Switching & Controls n Precision Cooling n Racks & Integrated Cabinets n Services Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2013 Emerson Electric Co. CND_DSUK_Rev1_06/2013