CN.D Series

advertisement
CN.D Series
Industrial Power for
Business-Critical Continuity™
DC Energy - Charger
CN.D chargers are designed to charge
12 V to 48 Vdc battery or maintain
larger battery used for Genset starter
or fire pumps Self.
Benefits
A robust charger batteries unit,
adapted to the difficult industrial environments,
supplemented effective protections increase
its reliability.
n Charger units for integration in cabinet
providing performances and data with
high quality level (regulation, reliability,
short circuit proof…).
n A clear indication two LED report mains
presence and indicate charging operation.
As an option three indicators and two relay
report alarm and a good accessibility give fast
maintenance.
n Small overall dimensions facilitate its
integration.
n Second voltage (Egalization mode) for
electrolytic cells batteries (Lead-acid and
NiCad).
n
They can also be integrated in box to provide power supplies with backup for
process control systems, or to LV/MV switchgears.
CN.D Series
Industrial Power for
Business-Critical Continuity™
DC Energy - Charger
Nominal
Nominal
voltage (V) current (A)
1000027
CN.D 12-12
12
12
1011861
CN.D 08-24
24
8
1000029
CN.D 10-24
24
10
1011719
CN.D 12-24
24
12
1000030
CN.D 15-24*
24
15
1000035
CN.D 05-48
48
5
1007064
CN.D 08-48*
48
8
* Input single-voltage : 230 V (on request: 400 V)
Code
Reference
Input power
(VA)
330
405
485
600
750
485
800
Protection
Weight
Input Output (Kg)
2
20
5.0
2
16
5.0
2
20
5.2
4
20
6.8
4
25
6.8
2
10
5.2
4
16
7.0
This publication is issued to provide outline information only and is not deemed to form any part of any offer and/or contract. The company has a policy of continuous product development and improvement, and we therefore reserve the right to vary
any information without prior notice. Crédits Photos : Georges Rivalain, iStockPhoto, Fotolia. SERIE CN.D-DSUK-Rev0-07/2012
Technical Specification
Dimensions
HxWxD
140x150x157
140x150x157
140x150x157
140x150x175
140x150x175
140x150x157
140x150x175
General data
Mains inputs voltage
230 - 400 VAC single phase -10% +15% - 50 Hz & -10% +25% - 60 Hz
Static regulation
± 1%
Short circuit current limitation
from 0.75 x In to In
Filtering
< 6% battery disconnected
Ambient operating temperature / Storage
-5° to +50 °C / -40° à +50°C
Relative humidity
< 95% with 20°C («all climates»)
LED signals
« Mains » and « Egalization mode » on
For futher details please refer to technical data sheet
Options
Reference Designation
4
Manual charge (equilizing) : jumper on 2 terminals
E
Manual charge (equilizing) with led signaling controlled by switch + adjusting potentiometer
X
Two automatic charging levels (floating/rapid charge) with electronic double timer (loose part if open
frame fitting)
T
Voltage regulation with temperature compensation
mD
Alarm card, allowing to detect :
• Battery low voltage with 10 sec timer. LED + voltage free contact
• A real charger failure combinig a low dc volt alarm enslaving to mains availability and a high dc volt alarm.
LED + volt free contact
Other
Input voltage / output voltage / rating
Specific version - Parallel operation - Casing fitting
Standards
Compliance
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity™.
ECM n°2004/108/CE - NF EN 61000-6-2 / NF EN 61000-6-4
LV n°2006/95/CE - NF EN 60439-1
Transformers comply to NF EN 61558-2-6
n AC Power
n Connectivity
n DC Power
n Embedded Computing
Emerson Network Power IS SAS
30 avenue Montgolfier - BP90 - 69684 Chassieu Cedex France
T +33 (0) 4 72 47 63 77 - F +33 (0) 4 78 40 13 94
E aees@emerson.com / www.aees.fr
EmersonNetworkPower.com
n Embedded Power
n Industrial Power
n Infrastructure Management & Monitoring
n Outside Plant
n Power Switching & Controls
n Precision Cooling
n Racks & Integrated Cabinets
n Services
Emerson, Business-Critical Continuity and
Emerson Network Power are trademarks of
Emerson Electric Co. or one of its affiliated companies.
©2011 Emerson Electric Co.
E-0000 000
Download