CN.D Series Industrial Power for Business-Critical Continuity™ DC Energy - Charger CN.D chargers are designed to charge 12 V to 48 Vdc battery or maintain larger battery used for Genset starter or fire pumps Self. Benefits A robust charger batteries unit, adapted to the difficult industrial environments, supplemented effective protections increase its reliability. n Charger units for integration in cabinet providing performances and data with high quality level (regulation, reliability, short circuit proof…). n A clear indication two LED report mains presence and indicate charging operation. As an option three indicators and two relay report alarm and a good accessibility give fast maintenance. n Small overall dimensions facilitate its integration. n Second voltage (Egalization mode) for electrolytic cells batteries (Lead-acid and NiCad). n They can also be integrated in box to provide power supplies with backup for process control systems, or to LV/MV switchgears. CN.D Series Industrial Power for Business-Critical Continuity™ DC Energy - Charger Nominal Nominal voltage (V) current (A) 1000027 CN.D 12-12 12 12 1011861 CN.D 08-24 24 8 1000029 CN.D 10-24 24 10 1011719 CN.D 12-24 24 12 1000030 CN.D 15-24* 24 15 1000035 CN.D 05-48 48 5 1007064 CN.D 08-48* 48 8 * Input single-voltage : 230 V (on request: 400 V) Code Reference Input power (VA) 330 405 485 600 750 485 800 Protection Weight Input Output (Kg) 2 20 5.0 2 16 5.0 2 20 5.2 4 20 6.8 4 25 6.8 2 10 5.2 4 16 7.0 This publication is issued to provide outline information only and is not deemed to form any part of any offer and/or contract. The company has a policy of continuous product development and improvement, and we therefore reserve the right to vary any information without prior notice. Crédits Photos : Georges Rivalain, iStockPhoto, Fotolia. SERIE CN.D-DSUK-Rev0-07/2012 Technical Specification Dimensions HxWxD 140x150x157 140x150x157 140x150x157 140x150x175 140x150x175 140x150x157 140x150x175 General data Mains inputs voltage 230 - 400 VAC single phase -10% +15% - 50 Hz & -10% +25% - 60 Hz Static regulation ± 1% Short circuit current limitation from 0.75 x In to In Filtering < 6% battery disconnected Ambient operating temperature / Storage -5° to +50 °C / -40° à +50°C Relative humidity < 95% with 20°C («all climates») LED signals « Mains » and « Egalization mode » on For futher details please refer to technical data sheet Options Reference Designation 4 Manual charge (equilizing) : jumper on 2 terminals E Manual charge (equilizing) with led signaling controlled by switch + adjusting potentiometer X Two automatic charging levels (floating/rapid charge) with electronic double timer (loose part if open frame fitting) T Voltage regulation with temperature compensation mD Alarm card, allowing to detect : • Battery low voltage with 10 sec timer. LED + voltage free contact • A real charger failure combinig a low dc volt alarm enslaving to mains availability and a high dc volt alarm. LED + volt free contact Other Input voltage / output voltage / rating Specific version - Parallel operation - Casing fitting Standards Compliance Emerson Network Power. The global leader in enabling Business-Critical Continuity™. ECM n°2004/108/CE - NF EN 61000-6-2 / NF EN 61000-6-4 LV n°2006/95/CE - NF EN 60439-1 Transformers comply to NF EN 61558-2-6 n AC Power n Connectivity n DC Power n Embedded Computing Emerson Network Power IS SAS 30 avenue Montgolfier - BP90 - 69684 Chassieu Cedex France T +33 (0) 4 72 47 63 77 - F +33 (0) 4 78 40 13 94 E aees@emerson.com / www.aees.fr EmersonNetworkPower.com n Embedded Power n Industrial Power n Infrastructure Management & Monitoring n Outside Plant n Power Switching & Controls n Precision Cooling n Racks & Integrated Cabinets n Services Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2011 Emerson Electric Co. E-0000 000