UNITRONIC LiYY (TP)

advertisement
en
Data Cables (LF) and Telephone Cables
Low frequency cables (LF)
Data cable with DIN colour code
Shortcut: PL34 - LAYOUT: Layout2
UNITRONIC LiYY (TP)
The pair twisted data transmission cables
Data Cables (LF) and Telephone Cables
Low frequency cables (LF)
Data cable with DIN colour code
PL34
Farbe_Kap06
UNITRONIC® LiYY (TP)
218
69
95
184
PRO201
Application
Electronic systems normally
have little space available for
cable installation. Short distances and small bending
radii required. Only low currents are normal, therefore use
of small conductor cross-sections is possible. These twisted
pair data cables are also
extremely flexible.
Cable Make-up
Bare copper wire stranded
conductor, PVC core insulation
and outer sheath, colour code
in accordance with DIN 47100,
flame retardant in accordance
with IEC 60332-1-2, pebble
grey (RAL 7032).
Special feature
Twisted in pairs to considerably reduce decoupling. Often,
no additional screening is
required. Robust PVC outer
sheath
Note
For special applications with
additional screening, we recommend the version UNITRONIC
LiYCY (TP). (TP) = Twisted Pair.
Technical Data
Core identification code
DIN 47100, see Table T9
Based on
VDE 0814: (DIN 47414)
or VDE 0812
Mutual capacitance
Approx. 120 nF/km
Specific insulation resistance
> 20 GOhm x cm
Peak working voltage
(not for power applications)
250 V
Part number
0035101
0035102
0035103
0035104
0035105
0035108
0035110
0035111
0035113
0035114
0035118
0035122
Coupling
(1 kHz) approx. 300 pF at 100 m
Number of pairs and Outer diameter Copper weight
mm² per conductor in mm approx. kg/km
UNITRONIC LiYY (TP)
2 x 2 x 0.14
3 x 2 x 0.14
4 x 2 x 0.14
5 x 2 x 0.14
6 x 2 x 0.14
10 x 2 x 0.14
12 x 2 x 0.14
14 x 2 x 0.14
16 x 2 x 0.14
18 x 2 x 0.14
25 x 2 x 0.14
30 x 2 x 0.14
Inductivity
approx. 0.65 mH/km
4,8
4,9
5,5
5,7
6,2
8,0
8,2
8,6
9,1
9,6
11,8
12,2
5,4
8,0
10,7
13,4
16,1
26,9
32,3
37,6
43,0
48,4
67,0
81,0
Weight kg/km
approx.
25,5
32,0
38,5
45,5
51,0
77,5
94,5
105,5
110,5
119,5
180,5
199,5
Test voltage
At 0.14 mm2: 1200 V
> 0.14 mm2: 1500 V
Conductor stranding
Strand, fine wire
Loop resistance
2 x value in table conductor
resistances table T11
Minimum bending radius
For flexible applications:
10 x cable diameter
Part number
Range of temperature
Operation: -30 °C to +70 °C
Number of pairs and Outer diameter Copper weight
mm² per conductor in mm approx. kg/km
Weight kg/km
approx.
0035130
50 x 2 x 0.14
15,8
134,0
387,0
0035160
0035161
0035162
0035163
0035164
0035165
2 x 2 x 0.25
3 x 2 x 0.25
4 x 2 x 0.25
6 x 2 x 0.25
8 x 2 x 0.25
10 x 2 x 0.25
6,1
6,2
6,9
7,8
9,2
10,3
9,6
14,4
19,2
28,8
38,4
48,0
38,0
48,0
59,0
80,0
98,0
115,0
0035170
0035171
0035172
0035174
0035175
2 x 2 x 0.5
3 x 2 x 0.5
4 x 2 x 0.5
8 x 2 x 0.5
10 x 2 x 0.5
7,9
8,0
8,7
12,2
13,2
19,2
28,8
38,4
76,8
96,0
72,0
83,0
115,0
206,0
247,0
Copper price basis: EUR 150 / 100 kg
Standard lengths: (100; 500; 1000) m
Packaging size: Coil < 30 kg, above automatically drum
Please specify the desired make-up (e.g. 1 x 500 m drum or 5 x 100 m coils)
275