id led 6" round housing - downlight ® FL6D LUMINAIRE MUST BE INSTALLED PRIOR TO DRYWALL CEILING. ALL GRID LUMINAIRES MUST BE SECURED TO STRUCTURE ABOVE. optional non-emergency - bar hangers key sold separately power off power on level attention see additional instructions emergency - integral test switch emergency - remote test switch GRID - 1/2” CONDUIT & CLIP (BY OTHERS) 1 2 X2 3 x4 619/32” min 65/8” max GRID - BAR HANGERS (SOLD SEPARATELY) 2 X2 3a x4 3b multiple luminaires only Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. IS0287 REV. B 2013 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 4 DRYWALL - BAR HANGERS (SOLD SEPARATELY) 2 WOOD STUDS X2 3a METAL STUDS 3 3b x4 x4 4 x4 1/4" max above ceiling EMERGENCY 5 B A PULL PIN TO RELEASE make electrical connections C D See Battery Manufacturer Instructions BATTERY UNIT CONNECTOR INSIDE do not mate connector until installation is complete and a.c. power is supplied Fixtures must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. IS0287 REV. B 2013 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 4 (JBOX SIDE) EMERGENCY - REMOTE TEST SWITCH ONLY E F 11 G release indicator from bracket prior to installation Ø 7/8" 2 1/2" ± 1/4" (EDGE OF FLANGE TO CENTER OF HOLE) H adjust indicator until canopy is flush with ceiling LIGHT MODULE SERVICE note: 3mm hex key required 2 3 1 REMOVE TRIM KEEP THERMAL PAD FOR REINSTALL SEE TRIM REMOVAL ON FOCAL POINT INSTRUCTION SHEET IS0288 4 5 11 REPLACE THERMAL PAD Fixtures must be installed by a qualified electrician (check with local and national codes for proper installation). To prevent electrical shock, disconnect electrical supply before installation or servicing. IS0287 REV. B 2013 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 4 DRIVER SERVICE 1 2 3 REMOVE TRIM SEE TRIM REMOVAL ON FOCAL POINT INSTRUCTION SHEET IS0288 PULL PIN TO RELEASE 4 WIRING DIAGRAM WHITE (NEUTRAL) BLACK (LINE) THERMAL PROTECTOR **OPTION WITH 2000Lm MODULES ONLY** NUVENTIX DLM COOLER WHITE BLACK GRAY ORANGE RED BLACK BLUE GREEN WHITE GRAY BLACK PURPLE GRAY BLUE RED YELLOW BLACK 0-10V DIMMER PURPLE GRAY NUVENTIX COOLER APPLICATION NOTES Standard Performance* No connection to the Blue Wire or to the Purple Wire High Performance Connect the Blue Wire to the Black Wire Silent Performance Connect the Purple Wire to the Black Wire Off Connect the Blue Wire and the Purple Wire to the Black Wire * Default Setting Level if control not used Contractor is responsible for adequately reinforcing walls and/or ceilings to support fixture weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC is prohibited. IS0287 REV. B 2013 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 4 of 4