id® led 6" round housing- downlight

advertisement
id led 6" round housing - downlight
®
FL6D
LUMINAIRE MUST BE INSTALLED PRIOR TO DRYWALL CEILING.
ALL GRID LUMINAIRES MUST BE SECURED TO STRUCTURE ABOVE.
optional
non-emergency
- bar hangers
key
sold separately
power off
power on
level
attention
see additional instructions
emergency
- integral test switch
emergency
- remote test switch
GRID - 1/2” CONDUIT & CLIP (BY OTHERS)
1
2
X2
3
x4
619/32” min
65/8” max
GRID - BAR HANGERS (SOLD SEPARATELY)
2
X2
3a
x4
3b
multiple luminaires only
Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
IS0287 REV. B 2013 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com
1 of 4
DRYWALL - BAR HANGERS (SOLD SEPARATELY)
2
WOOD STUDS
X2
3a
METAL STUDS
3
3b
x4
x4
4
x4
1/4"
max
above ceiling
EMERGENCY
5
B
A
PULL PIN TO
RELEASE
make electrical connections
C
D
See Battery
Manufacturer
Instructions
BATTERY UNIT CONNECTOR INSIDE
do not mate connector
until installation
is complete and a.c.
power is supplied
Fixtures must be installed by a qualified electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
IS0287 REV. B 2013 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com
2 of 4
(JBOX SIDE)
EMERGENCY - REMOTE TEST SWITCH ONLY
E
F
11
G
release
indicator
from bracket
prior to
installation
Ø 7/8"
2 1/2" ± 1/4" (EDGE OF FLANGE TO CENTER OF HOLE)
H
adjust indicator until
canopy is flush with ceiling
LIGHT MODULE SERVICE
note:
3mm hex key required
2
3
1
REMOVE TRIM
KEEP
THERMAL
PAD FOR
REINSTALL
SEE TRIM REMOVAL ON
FOCAL POINT INSTRUCTION
SHEET IS0288
4
5
11
REPLACE
THERMAL
PAD
Fixtures must be installed by a qualified electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
IS0287 REV. B 2013 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com
3 of 4
DRIVER SERVICE
1
2
3
REMOVE TRIM
SEE TRIM REMOVAL ON
FOCAL POINT INSTRUCTION
SHEET IS0288
PULL PIN TO
RELEASE
4
WIRING DIAGRAM
WHITE
(NEUTRAL)
BLACK
(LINE)
THERMAL PROTECTOR
**OPTION WITH 2000Lm MODULES ONLY**
NUVENTIX DLM COOLER
WHITE
BLACK
GRAY
ORANGE
RED
BLACK
BLUE
GREEN
WHITE
GRAY
BLACK
PURPLE
GRAY
BLUE
RED
YELLOW
BLACK
0-10V DIMMER
PURPLE
GRAY
NUVENTIX COOLER APPLICATION NOTES
Standard Performance*
No connection to the Blue Wire or to the Purple Wire
High Performance
Connect the Blue Wire to the Black Wire
Silent Performance
Connect the Purple Wire to the Black Wire
Off
Connect the Blue Wire and the Purple Wire to the Black Wire
* Default Setting Level if control not used
Contractor is responsible for adequately reinforcing walls and/or ceilings to support fixture weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or
ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC
is prohibited.
IS0287 REV. B 2013 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com
4 of 4