- Focal Point Lights

advertisement
seem 4 led surface mount
™
FSM4LS-SM
configurations are run specific, please consult factory drawings before beginning installation.
key
focal point
Uindividual
power off
attention
power on
see additional
instructions
individual
insallations follow
steps 1-3 & 7-10
Sstart of run
Iintermediate
MOUNTING
2'
3'
Eend of run
4'
5'
parts lists
6'
shipped in hardware bag
2.50”
5.99”
12.00”
5.99”
5.99”
24.00”
36.00”
11.99”
36.00”
11.99”
48.00”
7'
11.99”
20.00”
20.00”
8'
reflector (70008)
(6-32 X 5/16 PAN-HEAD
MACHINE SCREW)
20.00”
lens tool
11.99”
24.00”
24.00”
24.00”
(A09052-02)
(AFFIXED TO HOUSING.
ONE PER RUN)
feed location is always centered in housing.
shipped installed
use single device cover or single gang handy box
joiner
bracket
joiner pin
and mounting hardware (by others)
(18338)
(W5687)
lens end piece
(A08904)
joiner bracket
(11849)
Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
IS0519 Rev. D
2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com
1 of 3
11
1
3
11
2
SECURE HOUSING TO
STRUCTURE ABOVE.
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
(HARDWARE BY OTHERS.)
11
4
5
7
8
make electrical connections
6
secure reflectors to housing
(2 screws per reflector)
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
9
REFERENCE INSTRUCTIONS ON INCLUDED
TOOL FOR LENS INSTALLATION.
10
Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
IS0519 Rev. D
2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com
2 of 3
DRIVER SERVICE
11
1
11
3
2
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
EMERGENCY
SEE BATTERY MANUFACTURER
INSTRUCTIONS
emergency maximum mounting height:
19.00'
Contractor is responsible for adequately reinforcing walls and/or ceilings to support luminaire weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls
and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC
is prohibited.
IS0519 Rev. D
2016 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com
3 of 3