COOPER LIGHTING - LUMARK ® DESCRIPTION The Vertimark II delivers horizontal and vertical footcandles to evenly illuminate parking garage areas. The combination die-cast reflector/ballast housing makes Vertimark II economical. Modular assembly makes installation easy and quality construction ensures years of consistent performance. U.L. listed and labeled for damp location. CSA Certified. Durable construction and dependable performance make the Vertimark II perfect for parking garages. Optional U.L. wet location listing available. Catalog # Type Project Comments Date Prepared by S P E C I F I C AT I O N F E AT U R E S Construction Optical Mounting HOUSING: Die-cast aluminum housing has durable white polyester powder coat finish. REFRACTOR HINGE: Hinged refractor permits relamping without removal of refractor. BALLAST COMPARTMENT: Removable ballast compartment cover provides easy internal access. REFLECTOR: Acrylic prismatic refractor controls light for high vertical and horizontal footcandles. PENDANT MOUNTING: Standard quick mounting plate for 3/4" IPS conduit frees both hands to complete wiring. OPTIONAL J-BOX MOUNTING: Factory-installed mounting bracket fits a standard 4" J-Box for outlet box or surface mounting. BE VERTIMARK II 100 - 250W High Pressure Sodium Pulse Start Metal Halide Metal Halide ALUMINUM LOW-BAY DIMENSIONS Surface 12 1/2” [318mm] Pendant 13 1/4” [337mm] T E C H N I C A L D ATA EISA Compliant G 90°C Supply Wire Rating 17” [432mm] O P T I O N A L J - B OX STA N DA R D E Z 1 2 3 M O U N T I N G E N E R G Y D ATA Reactor Ballast Input Watts 70W HPS NPF/HPF (82 Watts) 100W HPS HPF (118 Watts) 150W HPS HPF (175 Watts) High-Reactance Ballast Input Watts 100W HPS HPF (130 Watts) 150W HPS HPF (190 Watts) CWA Ballast Input Watts 175W MP HPF (198 Watts) G 200W MP HPF (227 Watts) G 250W MP HPF (283 Watts) G 3/4" [19mm] S H I P P I N G D ATA Approximate Net Weight: 17 lbs. (8 kgs.) r eadily accepts the mating 5 1/8” [130mm] C 2 9/16” [654mm] YS ER TEM S fixture is easily attached. S half of the hinge and the D Once in place, the EZ123 TIFIE ADH082540 pc 2010-11-09 10:01:56 BE VERTIMARK II P H OTO M E T R I C S 90° 5 10 15 60° 20 25 30 35 40 45 50 CP/100 H P B E - 5 A - 1 5 0 H - 1 2 0 V- L L 150-Watt HPS 16,000-Lumen Clear Lamp 30° Coefficients Of Utilization Effective floor cavity reflectance = 20% rc 80% 70% rw 50 30 10 50 30 RCR 1 88 83 79 85 80 2 76 69 63 73 66 3 66 58 51 63 56 4 57 48 41 55 47 5 50 41 34 48 39 6 44 35 28 42 34 7 38 30 23 37 29 8 34 25 20 33 25 9 31 22 17 29 22 10 29 19 14 26 18 Spacing Criterion 1.6 Zone %Lamp Zone 0-30 11.67 0-90 0-40 19.95 90-180 0-60 53.54 Total 10 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 76 61 50 40 33 28 23 19 16 13 78 67 58 51 47 39 324 30 27 24 72 62 54 47 41 36 31 28 25 22 66 57 50 43 37 33 29 25 23 20 58 47 39 31 26 21 17 14 12 9 74 62 52 44 37 32 27 23 20 17 71 57 47 38 31 26 22 18 16 13 69 58 49 41 35 30 25 22 19 16 66 54 44 36 30 25 20 17 15 12 64 54 45 38 32 28 23 20 18 15 62 50 42 34 28 23 19 16 14 11 Candlepower Degree CP 0 2113 5 1888 15 1748 25 35 45 55 65 75 2308 2003 2329 3855 1964 1020 85 90 845 787 %Lamp 77.41 14.83 92.23 NOTE: Specifications and dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH082540 pc 2010-11-09 10:01:56 2010-11-09 11:11:41 BE VERTIMARK II ORDERING INFORMATION Sample Number: HPBE-5A-100H-MT-LL Lamp Type MP=Pulse Start Metal1 Halide MH=Metal Halide1, 2 HP=High Pressure 3, 4 Sodium Options 11 C3=3' Cord with no plug (Specify Voltage)12, 13 __=Normal Power Factor PC3=3' Cord with NEMA Plug (120V-L5-15P, 208V-L6-15P, 347V-L37-20P, AND 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6' Cord) Requires FH-1 or FL-1, or SHK. Example: PC3-120V Use with TPPH-NEMA. Specify Voltage. Voltage 6 120V=120V Series BE=Vertimark II 208V=208V 240V=240V PHC-NEMA=Power Cord and NEMA Plug (18" Power Cord and 20 AMP NEMA plug configuration). Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook). 480V=480V7 MT=Multi-Tap, wired8 277V 5A=Type V Lens 5 2P=Type II Polycarbonate Lens TT=Triple-Tap, wired 9 347V 5 FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation) Lamp Included LL=Lamp Included Lamp Wattage FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation) __=Lamp Not Included SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation) Socket 10 OR=Open Rated Socket for Metal Halide Lamps F1=Single Fuse (120, 277 or 347V only) F2=Double Fuse (208, 240 or 480V only) MP 100=100W 175=175W 200=200W 250=250W MH SCF=3' Aircraft Safety Cable secures Housing to 12 Ceiling (Alternative lengths available. Example: SCF6 = 6' Cable) __=Non Applicable (HPS or Not compatible with OR Socket) 1, 2 175=175W 250=250W Q=Quartz Restrike (Hot Strike Only)15 EM=Quartz Restrike with ''Delay Relay'' (Quartz 15 lamp strikes at both hot and cold starts) HP EM/SC=Emergency Separate Circuit15 100=100W 150=150W Notes: 1 12, 13 PHC=Power Cord and Plug (18" Power Cord and 14 Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage. 277V=277V 347V=347V Lens Type 2A=Type II Lens 5P=Type V Polycarbonate Lens Ballast H=High Power Factor L/TCB=Less Top Connector Box (Housing shipped less top connector box. (Specify when using TWMBS accessory) Open Rated socket and lamp must be used. Accessories C3=3' Cord-No Plug - Requires FH-1, FL-1, or SHK12, 13 12, 13 PC3=3' Cord with NEMA Plug - (120V-L5, 208V-L6-15P, 347V-L37-20P and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6' cord). Requires FH-1 or FL-1, or SHK. Use 14 PHC=Power Hook Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook) PHC-NEMA=Power Cord and NEMA plug - 18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook) MBT=Twin Mount Bracket (Fixtures must be same17 voltage and without hooks, loops or plugs.) TPPH=Thru-Way Pendant Power Hook. Requires FL-1 18 and PHC. Specify Voltage. TPPH-F=Thru-Way Pendant Power Hook Single Fuse, 18 120, 277 or 347 Volt. Requires FL-1 and PHC. Specify Voltage. TPPH-F2=Thru-Way Pendant Power Hook - Double 18 Fused, 208, 240, or 480 Volt. Requires FL-1 and PHC. Specify Voltage. TPPH-F-QD=Thru-Way Pendant Power Hook Single 18 Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (120, 277, or 347V) TPPH-F2-QD=Thru-Way Pendant Power Hook Double 18 Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (208, 240, or 480V) 19 TPPH-NEMA=Thru-Way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. (Specify Voltage). FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook with Safety Screw IA1025=Bracket for Surface Mounting to 4'' J-Box CEC=California Title 20 Compliant Ballast (Applies to 250-320W and 400-450W MP only) 2 MH available in non-U.S. markets only. 3 150W maximum. 4 Not available in 175, 200, 320 and 350W. 5 Not recommended for use with Metal Halide lamps due to rapid yellowing typical of polycarbonate material. 6 Products also available in non-US voltages and 50HZ for international markets. Consult your Cooper Representative for availabiltiy and ordering information. 88% Efficient EISA Compliant MP Fixtures not available in 347V and TT Voltages. 7 Not available with 200W or 250W Pulse Start Metal Halide. 8 Multi-Tap ballast 120/208/240/277V wired 277V. 9 Triple-Tap ballast 120/277/347V wired 347V. 10 Not applicable for HPS. 11 Must be listed in the order shown and separated by a dash. 12 Other lengths are available. 13 Requires FH-1or FL-1or SHK. 14 Requires FL-1 and TPPH. 15 Quartz lamp wattage is 100W maximum. 16 Not available with PC3, C3, PHC or MWS. Not available with single circuit MWS special order. 17 Fixtures must be same wattage and voltage and without hooks, loops or plugs. 18 Requires FL-1 and PHC. 19 Requires FL-1 and PHC-XXXV-NEMA. P=Mounting Bracket for Surface or 4'' J-Box W/MWS=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft. 6 ft. and 11 ft. also available. Please refer to MWS Modular Wiring System section for additional information. 16 HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures outside AC conduit run similar to low voltage intercom's, fire alarms and phone systems) WLB=UL Labeled for Wet Locations with Die-Cast Box for 3/4'' Conduit WLD=UL Labeled for Wet Locations with Quick Disconnect WLP=UL Labeled for Wet Locations Suitable for Surface or 4'' J-Box Mounting LAMP TYPE WATTAGE Pulse Start Metal Halide (MP) 100, 175, 200, 250W Metal Halide (MH) 175, 250W High Pressure Sodium (HPS) 100, 150W VOLTAGE CHART MT=Multi-Tap 120/208/240/277 (wired 277V) TT=Triple-Tap 120/277/347 (wired 347V) NOTE: Specifications and dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH082540 pc 2010-11-09 10:01:56 2010-11-09 11:11:41