Lumark DESCRIPTION The Enhanced Refractor high-bay combines the popular Steeler ballast housing with a microcellular translucent white acrylic refractor. This technology provides architectural appeal and improved lighting performance at higher ambient ratings. U.L. Listed and CSA certified for damp locations. The Enhanced Refractor high-bay is perfect for architectural applications like retail stores, wholesale warehouses, grocery chains, malls, and auto showrooms. The higher ambient performance makes this suitable for general warehouse and manufacturing applications. Catalog # Type Project Comments Date Prepared by S P E C I F I C AT I O N F E AT U R E S Construction Electrical Optical HOUSING: Heavy-duty, formed steel housing with an open air ballast for cooler operation is finished in a white polyester paint. UNIVERSAL BRACKETS: Universal ladder brackets allow for the flexibility to change out with other reflectors available in aluminum or glass. BALLAST: High power factor ballast with class H insulation. Minimum starting temperatures is -40° C (-40° F) for HPS and -30° C (-20° F) for MH, MP & ML. CSA certified. SOCKET: Mogul-base socket standard for HPS. For Metal Halide, protected socket standard, for use with "O" (open) rated protected Metal Halide lamps only. REFRACTOR: Easily mounted microcellular translucent white prismatic acrylic refractor has multiple field-adjustable distribution patterns for precision control without the glare of traditional clear acrylics. Mounting Easy slide-on die-cast aluminum mounting box with tapped opening for 3/4" conduit. SS 22" ENHANCED REFRACTOR 175 - 450W High Pressure Sodium Pulse Start Metal Halide Metal Halide ACRYLIC HIGH-BAY T E C H N I C A L D ATA EISA Compliant G Maximum Ambient Temperatures. 65°C Open Bottom 55°C Glass Bottom 40°C Drop Acrylic Bottom External Supply Wire Rating 90° Minimum Drop Bottom adds 3 1/2” to overall height 22” [559mm] S H I P P I N G D ATA Approximate Net Weight: 29 lbs. (13 kgs.) YS C ER TEM S (Drop Bottom adds 3 1/2” to overall height) CWA Ballast Input Watts 175W MP HPF (198 Watts) G 200W MP HPF (227 Watts) G 250W MP HPF (283 Watts) G 320W MP HPF (365 Watts) G 350W MP HPF (400 Watts) G 400W MP HPF (452 Watts) G 400W HPS HPF (465 Watts) 450W MP HPF (508 Watts) G D 22” Refractor Maximum height with EB22 is 28 1/2” [724mm] E N E R G Y D ATA CWI Ballast Input Watts 250W HPS HPF (300 Watts) 250W MH HPF (300 Watts) 400W HPS HPF (465 Watts) 400W MH HPF (475 Watts) S DIMENSIONS TIFIE ADH082398 2015-12-02 11:13:08 SS 22" ENHANCED REFRACTOR P H OTO M E T R I C S 90 2.9 60 5.9 30 8.9 11.9 CP/1000 M P S S - E R 2 2 - M - 4 0 0 - M T- Q 400-Watt MP 42,000-Lumen Clear Lamp Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Coefficients Of Utilization Effective floor cavity reflectance rc 80% 70% rw 70 50 30 10 70 50 30 RCR 1 94 90 86 83 90 86 83 2 86 79 74 69 82 76 71 3 79 70 64 58 75 68 62 4 73 63 56 50 69 60 54 5 67 56 49 43 64 54 47 6 62 51 43 38 59 49 42 7 57 46 39 34 55 45 38 8 53 42 35 30 51 41 34 9 50 38 32 27 48 37 31 10 47 35 29 24 45 34 28 10 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 80 67 57 49 42 37 33 29 26 24 79 70 63 56 50 46 42 38 35 32 73 65 58 52 47 43 39 36 33 30 67 60 54 48 44 40 36 33 31 29 61 52 45 39 34 30 27 24 22 20 Spacing Criterion 1.5 Zone %Lamp Zone 0-30 22.0 0-90 %Lamp 71.9 0-40 0-60 17.4 89.3 37.9 61.3 90-180 Total Specifications and dimensions subject to change without notice. 77 66 58 51 45 40 36 32 29 27 75 63 54 46 40 36 32 28 25 23 71 62 54 47 42 38 34 31 28 26 69 59 51 44 38 34 30 27 24 22 66 57 50 45 40 36 32 29 27 24 64 55 48 42 36 32 29 26 23 21 Candlepower Degree CP 0 11840 5 11478 15 11321 25 11845 35 11270 45 8895 55 4232 65 2449 75 1384 85 636 95 592 105 763 115 833 125 878 135 2128 145 2788 155 2058 165 738 175 568 180 594 ADH082398 2015-12-02 11:13:08 ORDERING INFORMATION Sample Number: MPSS-ER22-C-175-120V-OR Lamp Type MP=Pulse Start Metal 1 Halide MH=Metal Halide1, 2 Reflector Type ER=Enhanced Prismatic Reflector HP=High Pressure 3 Sodium Reflector Diameter 22=22'' Diameter Series SS=Steeler Distribution 4 C=Concentrated M=Medium W=Wide Lamp Wattage Voltage MP 208V 175=175W 200=200W 250=250W 320=320W 400=400W 450=450W MH 2 175=175W 250=250W 400=400W HP 250=250W 400=400W Open Rated socket and lamp must be used. Notes: 1 5 120V 240V 277V 347V 480V MT 6 TT 7 5T 8 Socket OR=Open Rated 9 Socket for Metal Halide Lamps __=Non Applicable (HPS or Not compatible with OR Socket) 2 MH available in non-U.S. markets only. 3 Not available in 175, 320 and 350W. 4 Factory set for concentrated, medium or wide distributions otherwise fixture is shipped in medium setting. 5 Products also available in non-US voltages and 50HZ for international markets. Consult your Cooper Representative for availabiltiy and ordering information. 88% Efficient EISA Compliant MP Fixtures not available in 347V and TT Voltages. 6 Multi-Tap ballast 120/208/240/277V wired 277V. 7 Triple-Tap ballast 120/277/347V wired 347V. 8 5-Tap ballast 120/208/240/277/480V wired 277V. 400W Metal Halide only. 88% efficient EISA Compliant MP fixtures not available in 5-Tap Voltages. 9 Not applicable for HPS. 10 Requires FH-1or FL-1or SHK. 11 30 second time delay when switching from bright to dim. Consult individual lamp manufacturers recommendations for compatible lamps. For use with CWA ballast only. 12 Not available with HL or HC options. 13 Not available with PC3, C3, PHC or MWS. Not available with single circuit MWS special order. 14 Fixtures must be same wattage and voltage and without hooks, loops or plugs. 15 Specify L/TCB when using thru-way mounting box (TWMBS) accessory. Options C3=3' Cord with no plug (Specify Voltage)10 Accessories C3=3' Cord-No Plug - Requires FH-1, PC3=3' Cord with NEMA Plug (120V-L5-15P, 10 208V-L6-15P, 347V-L37-20P, AND 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6' Cord) Requires FH-1 or FL-1, or SHK. Example: PC3-120V Use with TPPH-NEMA. Specify Voltage. PC3=3' Cord with NEMA Plug - (120V-L5, 10 208V-L6-15P, 347V-L37-20P and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6' cord). Requires FH-1 or FL-1, or SHK. Use with TPPH-NEMA. Specify Voltage. PHC=Power Cord and Plug (18" Power Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage. PHC-NEMA=Power Cord and NEMA Plug (18" Power Cord and 20 AMP NEMA plug configuration). Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook). P=Pre-set Socket Position from the factory FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation) FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation) SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation) 10 FL-1, or SHK PHC=Power Hook Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook) PHC-NEMA=Power Cord and NEMA plug 18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook) SGB22A=(Not Compatible with WG22 400W max.) WG22/GLC=Gym Wireguard w/ Safety Glass WG22=Wire Guard for AC22 or PD 22" Refractor (Not compatible with SGB) DB22=Drop Acrylic for 22" refractor (400W max.) CB12=Conical Bottom Lens for 12" Refractor CB16=Conical Bottom Lens for 16" Refractor HSW=Integral LumaWatt Sensor and Control 11 w/ Wide Distribution MBT=Twin Mount Bracket (Fixtures must 14 be same voltage and without hooks, loops or plugs.) F1=Single Fuse (120, 277 or 347V only) F2=Double Fuse (208, 240 or 480V only) TPPH=Thru-Way Pendant Power Hook. Requires FL-1 and PHC. Specify Voltage. SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available. Example: SCF6 = 6' Cable) TPPH-F=Thru-Way Pendant Power Hook Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC. Specify Voltage. Q=Quartz Restrike (Hot Strike Only) EM=Quartz Restrike with ''Delay Relay'' (Quartz lamp strikes at both hot and cold starts) EM/SC=Emergency Separate Circuit12 L/TCB=Less Top Connector Box (Housing shipped less top connector box. (Specify when using TWMBS accessory) LL=Lamp Included SCR=Aircraft Safety Cable-Housing to Reflector W/MWS=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft. 6 ft. and 11 ft. also available. Please refer to MWS Modular Wiring System section for additional information. HC=LumaWatt Fixture Control Module 11, 13, 13 (Low voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) TPPH-F2=Thru-Way Pendant Power Hook Double Fused, 208, 240, or 480 Volt. Requires FL-1 and PHC. Specify Voltage. TPPH-F-QD=Thru-Way Pendant Power Hook Single Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (120, 277, or 347V) TPPH-F2-QD=Thru-Way Pendant Power Hook Double Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (208, 240, or 480V) TPPH-NEMA=Thru-Way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. (Specify Voltage). FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook with Safety Screw TWMBS=Thru-Way Mounting Box15, 15 11 HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures outside AC conduit run similar to low voltage intercom's, fire alarms and phone systems) LAMP TYPE WATTAGE Pulse Start Metal Halide (MP) 175, 200, 250, 320, 350, 400, 450W Metal Halide (MH) 175, 250, 400W High Pressure Sodium (HP) 250, 400W QLL=Quartz Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped separate from luminaire unless otherewise noted) VOLTAGE CHART MT=Multi-Tap TT=Triple-Tap 5T=5-Tap 9 120/208/240/277 (wired 277V) 120/277/347 (wired 347V) 120/208/240/277/480 (wired 277V) Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. ADH082398 2015-12-02 11:13:08