Catalog # Type

advertisement
Lumark
DESCRIPTION
The Enhanced Refractor high-bay combines the popular Steeler ballast
housing with a microcellular translucent white acrylic refractor. This
technology provides architectural appeal and improved lighting
performance at higher ambient ratings. U.L. Listed and CSA certified for
damp locations. The Enhanced Refractor high-bay is perfect for
architectural applications like retail stores, wholesale warehouses,
grocery chains, malls, and auto showrooms. The higher ambient
performance makes this suitable for general warehouse and
manufacturing applications.
Catalog #
Type
Project
Comments
Date
Prepared by
S P E C I F I C AT I O N F E AT U R E S
Construction
Electrical
Optical
HOUSING: Heavy-duty, formed
steel housing with an open air
ballast for cooler operation is
finished in a white polyester paint.
UNIVERSAL BRACKETS: Universal
ladder brackets allow for the
flexibility to change out with other
reflectors available in aluminum or
glass.
BALLAST: High power factor ballast
with class H insulation. Minimum
starting temperatures is -40° C (-40°
F) for HPS and -30° C (-20° F) for
MH, MP & ML. CSA certified.
SOCKET: Mogul-base socket
standard for HPS. For Metal Halide,
protected socket standard, for use
with "O" (open) rated protected
Metal Halide lamps only.
REFRACTOR: Easily mounted
microcellular translucent white
prismatic acrylic refractor has
multiple field-adjustable
distribution patterns for precision
control without the glare of
traditional clear acrylics.
Mounting
Easy slide-on die-cast aluminum
mounting box with tapped opening
for 3/4" conduit.
SS
22" ENHANCED
REFRACTOR
175 - 450W
High Pressure Sodium
Pulse Start Metal Halide
Metal Halide
ACRYLIC HIGH-BAY
T E C H N I C A L D ATA
EISA Compliant G
Maximum Ambient Temperatures.
65°C Open Bottom
55°C Glass Bottom
40°C Drop Acrylic Bottom
External Supply Wire Rating
90° Minimum
Drop Bottom adds 3 1/2”
to overall height
22” [559mm]
S H I P P I N G D ATA
Approximate Net Weight:
29 lbs. (13 kgs.)
YS
C
ER
TEM
S
(Drop Bottom adds 3 1/2” to overall height)
CWA Ballast Input Watts
175W MP HPF (198 Watts) G
200W MP HPF (227 Watts) G
250W MP HPF (283 Watts) G
320W MP HPF (365 Watts) G
350W MP HPF (400 Watts) G
400W MP HPF (452 Watts) G
400W HPS HPF (465 Watts)
450W MP HPF (508 Watts) G
D
22” Refractor
Maximum height with
EB22 is 28 1/2” [724mm]
E N E R G Y D ATA
CWI Ballast Input Watts
250W HPS HPF (300 Watts)
250W MH HPF (300 Watts)
400W HPS HPF (465 Watts)
400W MH HPF (475 Watts)
S
DIMENSIONS
TIFIE
ADH082398
2015-12-02 11:13:08
SS 22" ENHANCED REFRACTOR
P H OTO M E T R I C S
90
2.9
60
5.9
30
8.9
11.9
CP/1000
M P S S - E R 2 2 - M - 4 0 0 - M T- Q
400-Watt MP
42,000-Lumen Clear Lamp
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Coefficients Of Utilization
Effective floor cavity reflectance
rc
80%
70%
rw 70 50 30 10
70 50 30
RCR
1 94 90 86 83
90 86 83
2 86 79 74 69
82 76 71
3 79 70 64 58
75 68 62
4 73 63 56 50
69 60 54
5 67 56 49 43
64 54 47
6 62 51 43 38
59 49 42
7 57 46 39 34
55 45 38
8 53 42 35 30
51 41 34
9 50 38 32 27
48 37 31
10 47 35 29 24
45 34 28
10
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
80
67
57
49
42
37
33
29
26
24
79
70
63
56
50
46
42
38
35
32
73
65
58
52
47
43
39
36
33
30
67
60
54
48
44
40
36
33
31
29
61
52
45
39
34
30
27
24
22
20
Spacing Criterion
1.5
Zone
%Lamp
Zone
0-30
22.0
0-90
%Lamp
71.9
0-40
0-60
17.4
89.3
37.9
61.3
90-180
Total
Specifications and
dimensions subject to
change without notice.
77
66
58
51
45
40
36
32
29
27
75
63
54
46
40
36
32
28
25
23
71
62
54
47
42
38
34
31
28
26
69
59
51
44
38
34
30
27
24
22
66
57
50
45
40
36
32
29
27
24
64
55
48
42
36
32
29
26
23
21
Candlepower
Degree CP
0
11840
5
11478
15
11321
25
11845
35
11270
45
8895
55
4232
65
2449
75
1384
85
636
95
592
105
763
115
833
125
878
135
2128
145
2788
155
2058
165
738
175
568
180
594
ADH082398
2015-12-02 11:13:08
ORDERING INFORMATION
Sample Number: MPSS-ER22-C-175-120V-OR
Lamp Type
MP=Pulse Start Metal 1
Halide
MH=Metal Halide1, 2
Reflector Type
ER=Enhanced Prismatic
Reflector
HP=High Pressure 3
Sodium
Reflector Diameter
22=22'' Diameter
Series
SS=Steeler
Distribution 4
C=Concentrated
M=Medium
W=Wide
Lamp
Wattage
Voltage
MP
208V
175=175W
200=200W
250=250W
320=320W
400=400W
450=450W
MH
2
175=175W
250=250W
400=400W
HP
250=250W
400=400W
Open Rated socket and lamp must be used.
Notes: 1
5
120V
240V
277V
347V
480V
MT
6
TT
7
5T
8
Socket
OR=Open Rated 9
Socket for
Metal Halide
Lamps
__=Non Applicable
(HPS or Not
compatible with
OR Socket)
2
MH available in non-U.S. markets only.
3
Not available in 175, 320 and 350W.
4
Factory set for concentrated, medium or wide distributions otherwise fixture is shipped in medium setting.
5
Products also available in non-US voltages and 50HZ for international markets. Consult your Cooper
Representative for availabiltiy and ordering information. 88% Efficient EISA Compliant MP Fixtures not
available in 347V and TT Voltages.
6
Multi-Tap ballast 120/208/240/277V wired 277V.
7
Triple-Tap ballast 120/277/347V wired 347V.
8
5-Tap ballast 120/208/240/277/480V wired 277V. 400W Metal Halide only. 88% efficient EISA Compliant MP
fixtures not available in 5-Tap Voltages.
9
Not applicable for HPS.
10
Requires FH-1or FL-1or SHK.
11
30 second time delay when switching from bright to dim. Consult individual lamp manufacturers
recommendations for compatible lamps. For use with CWA ballast only.
12
Not available with HL or HC options.
13
Not available with PC3, C3, PHC or MWS. Not available with single circuit MWS special order.
14
Fixtures must be same wattage and voltage and without hooks, loops or plugs.
15
Specify L/TCB when using thru-way mounting box (TWMBS) accessory.
Options
C3=3' Cord with no plug (Specify Voltage)10
Accessories
C3=3' Cord-No Plug - Requires FH-1,
PC3=3' Cord with NEMA Plug (120V-L5-15P, 10
208V-L6-15P, 347V-L37-20P, AND
480V-L8-20P) Other cord lengths are
available by specifying length (PC6 for
6' Cord) Requires FH-1 or FL-1, or
SHK. Example: PC3-120V Use with
TPPH-NEMA. Specify Voltage.
PC3=3' Cord with NEMA Plug - (120V-L5, 10
208V-L6-15P, 347V-L37-20P and
480V-L8-20P) Other cord lengths
are available by specifying length
(PC6 for 6' cord). Requires FH-1 or
FL-1, or SHK. Use with
TPPH-NEMA. Specify Voltage.
PHC=Power Cord and Plug (18" Power Cord
and Non-NEMA plug configuration. Must
be used with FL-1 and TPPH (Thru-Way
Pendant Power Hook). Must specify
single voltage.
PHC-NEMA=Power Cord and NEMA Plug (18"
Power Cord and 20 AMP NEMA
plug configuration). Must be
used with FL-1 and TPPH-NEMA
(Thru-Way Pendant Power
Hook).
P=Pre-set Socket Position from the factory
FH-1=Die-cast Aluminum Fixture Hook (with
3/4" threads for easy installation)
FL-1=Malleable Iron Plated Fixture Loop (with
3/4" threads for easy installation)
SHK=Die-cast Aluminum Fixture Hook (with
safety screw and 3/4" threads for easy
installation)
10
FL-1, or SHK
PHC=Power Hook Cord and Non-NEMA
plug configuration. Must be used with
FL-1 and TPPH (Thru-Way Pendant
Power Hook)
PHC-NEMA=Power Cord and NEMA plug 18" Power Cord and 20 Amp
NEMA plug configuration.
Must be used with FL-1 and
TPPH-NEMA (Thru-Way
Pendant Power Hook)
SGB22A=(Not Compatible with WG22 400W max.)
WG22/GLC=Gym Wireguard w/ Safety
Glass
WG22=Wire Guard for AC22 or PD 22"
Refractor (Not compatible with SGB)
DB22=Drop Acrylic for 22" refractor
(400W max.)
CB12=Conical Bottom Lens for 12"
Refractor
CB16=Conical Bottom Lens for 16"
Refractor
HSW=Integral LumaWatt Sensor and Control 11
w/ Wide Distribution
MBT=Twin Mount Bracket (Fixtures must 14
be same voltage and without hooks,
loops or plugs.)
F1=Single Fuse (120, 277 or 347V only)
F2=Double Fuse (208, 240 or 480V only)
TPPH=Thru-Way Pendant Power Hook.
Requires FL-1 and PHC. Specify
Voltage.
SCF=3' Aircraft Safety Cable secures
Housing to Ceiling (Alternative lengths
available. Example: SCF6 = 6' Cable)
TPPH-F=Thru-Way Pendant Power Hook
Single Fuse, 120, 277 or 347 Volt.
Requires FL-1 and PHC. Specify
Voltage.
Q=Quartz Restrike (Hot Strike Only)
EM=Quartz Restrike with ''Delay Relay'' (Quartz
lamp strikes at both hot and cold starts)
EM/SC=Emergency Separate Circuit12
L/TCB=Less Top Connector Box (Housing
shipped less top connector box.
(Specify when using TWMBS
accessory)
LL=Lamp Included
SCR=Aircraft Safety Cable-Housing to
Reflector
W/MWS=MWS Industrial components attached
to the fixture at the factory. (Standard
cord length is 3 ft. 6 ft. and 11 ft. also
available. Please refer to MWS
Modular Wiring System section for
additional information.
HC=LumaWatt Fixture Control Module 11, 13, 13
(Low voltage leads pulled out of
top connection box for areas
requiring all wiring to be installed in
conduit)
TPPH-F2=Thru-Way Pendant Power Hook Double Fused, 208, 240, or 480
Volt. Requires FL-1 and PHC.
Specify Voltage.
TPPH-F-QD=Thru-Way Pendant Power
Hook Single Fuse, Quick
Disconnect. Requires FL-1
and PHC. Specify Voltage
(120, 277, or 347V)
TPPH-F2-QD=Thru-Way Pendant Power
Hook Double Fuse, Quick
Disconnect. Requires FL-1
and PHC. Specify Voltage
(208, 240, or 480V)
TPPH-NEMA=Thru-Way Pendant Power
Hook. Requires FL-1 and
PHC-XXXV-NEMA. (Specify
Voltage).
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook with Safety Screw
TWMBS=Thru-Way Mounting Box15, 15
11
HL=LumaWatt Fixture Control Module
(Allows low voltage control wire to be
daisy-chained between fixtures outside
AC conduit run similar to low voltage
intercom's, fire alarms and phone
systems)
LAMP TYPE
WATTAGE
Pulse Start Metal Halide (MP)
175, 200, 250, 320, 350, 400, 450W
Metal Halide (MH)
175, 250, 400W
High Pressure Sodium (HP)
250, 400W
QLL=Quartz Lamp Included (Lamp is Cooper
designated product based on luminaire
requirements. Lamp is shipped separate
from luminaire unless otherewise noted)
VOLTAGE CHART
MT=Multi-Tap
TT=Triple-Tap
5T=5-Tap
9
120/208/240/277 (wired 277V)
120/277/347 (wired 347V)
120/208/240/277/480 (wired 277V)
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
ADH082398
2015-12-02 11:13:08
Download