Catalog # Type

advertisement
Lumark
DESCRIPTION
The Vertimark features a durable die-cast aluminum top and spun
aluminum housing with a computer-designed optical system, making the
Vertimark an excellent choice for lighting areas requiring excellent
vertical light distribution. U.L. listed and labeled for damp location. CSA
Certified. Vertimark is designed to illuminate three-dimensional objects
such as machinery dials, spindles, presses, panels and stacked materials.
The predominant vertical footcandle distribution and higher beam angles
of Vertimark actually distribute light into shadowed areas typically found
on machinery and equipment.
Catalog #
Type
Project
Comments
Date
Prepared by
S P E C I F I C AT I O N F E AT U R E S
ConstructIon
REFRACTOR/DOOR: Hinged
refractor/door assembly has full
perimeter silicone gasketing with
easy access thumb screws.
Electrical
WIRING CHAMBER AND HUB:
Easy-access wiring chamber cover
with 3/4" IPS threaded hub for
quick fixture mounting. BALLAST
MOUNTING: Ballast and electrical
components are mounted to die-
cast aluminum top for cooler
operation. High power factor
ballast with class H insulation. U.L.
Listed for 55° C (131° F) ambient
temperature operation. Minimum
starting temperature is -40° C (-40°
F) for HPS and -30° C (-20° F) for
Metal Halide.
compartment. OPTICAL SYSTEM:
Computer-designed optical system
combines a translucent diffuser at
the top with a prismatic lens at the
bottom for maximum vertical
illumination.
Finish
Optical
Polyester powder coat finish for
long life and corrosion resistance.
REFLECTOR: Spun aluminum
reflector has internally hinged door
for toolless entry into electrical
VF
VERTIMARK
150 - 400W
High Pressure Sodium
Pulse Start Metal Halide
Metal Halide
ALUMINUM LOW-BAY
DIMENSIONS
T E C H N I C A L D ATA
EISA Compliant G
23 3/4”
[603mm]
E N E R G Y D ATA
CWI Ballast Input Watts
250W HPS HPF (300 Watts)
250W MH HPF (300 Watts)
400W HPS HPF (465 Watts)
400W MH HPF (475 Watts)
CWA Ballast Input Watts
175W MP HPF (198 Watts) G
200W MP HPF (227 Watts) G
250W MP HPF (283 Watts) G
320W MP HPF (365 Watts) G
350W MP HPF (400 Watts) G
400W MP HPF (452 Watts) G
400W HPS HPF (465 Watts)
S H I P P I N G D ATA
Approximate Net Weight:
45 lbs. (20 kgs.)
C
ER
TEM
D
YS
S
S
26 1/2” [673mm]
TIFIE
ADH082539
2015-12-02 11:58:59
VF
VERTIMARK
P H OTO M E T R I C S
90°
11
26
60°
41
57
30°
72
88
103
CP/100
HPVF-AL-400-MT
400-Watt HPS
50,000-Lumen Clear Lamp
Spacing Criterion
1.5
Zone
%Lamp
Zone
0-30
19.9
0-90
0-40
17.2
90-180
0-60
44.6
Total
90°
15
27
60°
40
52
Coefficients Of Utilization
Effective floor cavity reflectance = 20%
rc
80%
70%
rw
70 50 30 10
70 50 30
RCR
0
104 104 104 104
99 99 99
1
92 86 81 77
88 83 78
2
82 73 66 60
78 70 64
3
74 63 54 47
70 60 52
4
67 54 46 39
63 52 44
5
60 47 38 32
57 45 37
6
55 41 32 26
52 40 31
7
50 36 27 21
47 35 27
8
46 32 24 18
43 31 23
9
42 29 21 16
40 28 20
10
39 26 19 13
37 25 18
30°
65
77
90
CP/100
MPVF-AL-400-MT
400-Watt MP
44,000-Lumen Clear Lamp
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
50%
50 30 10
30%
50 30 10
10%
50 30 10
99
74
58
46
38
31
25
21
18
15
13
92
76
64
55
48
42
36
32
29
26
23
84
70
59
50
44
38
33
29
26
24
21
78
64
54
46
40
35
30
27
24
22
20
92
72
59
49
41
34
29
25
22
19
17
92
69
54
43
35
29
24
20
17
14
12
84
67
55
45
38
32
27
23
20
18
16
84
64
51
40
33
27
22
18
16
13
11
78
62
50
42
35
30
25
21
19
16
14
78
60
47
38
31
25
21
17
15
12
11
0%
0
75
57
44
35
29
23
19
15
13
10
9
%Lamp
74.7
15.5
90.2
Coefficients Of Utilization
Effective floor cavity reflectance = 20%
rc
80%
70%
rw
70 50 30 10
70 50 30
RCR
0
102 102 102 102
98 98 98
1
90 85 80 76
86 82 77
2
81 73 66 60
77 70 63
3
73 62 54 48
69 60 52
4
66 54 46 39
63 52 44
5
60 47 39 32
57 45 37
6
54 41 33 26
51 40 31
7
49 36 27 21
47 34 27
8
45 32 24 18
43 31 23
9
24 29 21 16
40 28 20
10
39 26 18 13
37 25 18
Spacing Criterion
1.5
Zone
%Lamp
Zone
0-30
10.1
0-90
0-40
17.5
90-180
0-60
47.6
Total
10
Candlepower
Degree CP
0
4380
5
4307
15
4071
25
4531
35
4187
45
5160
55
7704
65
4009
75
2667
85
2258
90
2069
10
50%
50 30 10
30%
50 30 10
10%
50 30 10
98
74
58
46
38
31
26
21
18
15
13
90
75
64
55
48
42
36
32
28
25
23
83
69
59
50
44
38
33
29
26
23
21
77
63
54
46
40
35
31
27
24
21
20
90
72
59
49
41
35
29
25
22
19
17
90
68
54
44
36
30
24
20
17
14
12
83
66
55
45
38
32
27
23
20
18
16
83
64
51
41
34
28
23
18
16
13
12
77
61
51
42
36
30
25
21
19
16
14
77
59
47
38
32
26
21
17
15
12
11
0%
0
74
56
45
36
29
24
19
15
13
11
9
Candlepower
Degree CP
0
7402
5
7137
15
6716
25
7635
35
7020
45
9242
10692
55
65
9080
75
4680
85
3853
90
3533
%Lamp
73.8
14.9
88.7
ADH082539
2015-12-02 11:58:59
VF
VERTIMARK
ORDERING INFORMATION
Sample Number: MPVF-AL-250-MT-OR-Q
Lamp Type
MP=Pulse Start Metal 1, 2
Halide
Lamp
Wattage
Voltage
MP
MH=Metal Halide2, 3
HP=High Pressure 4
Sodium
175=175W
200=200W
208V
Series
VF=Vertimark
Lens Type
AL=Prismatic
Acrylic Lens
PC3=3' Cord with NEMA Plug (120V-L5-15P,
208V-L6-15P, 347V-L37-20P, AND
480V-L8-20P) Other cord lengths are
available by specifying length (PC6 for 6'
Cord) Requires FH-1 or FL-1, or SHK.
Example: PC3-120V Use with
TPPH-NEMA. Specify Voltage.
240V
277V
250=250W
320=320W
347V
480V
350=350W
400=400W
MH
Options
C3=3' Cord with no plug (Specify Voltage)9
5
120V
MT
TT
3
175=175W
250=250W
6
7
Socket
OR=Open Rated Socket 8
for Metal Halide
Lamps
400=400W
HP
__=Non Applicable (HPS
or Not compatible with
OR Socket)
150=150W
250=250W
400=400W
Notes: 1
9
PHC=Power Cord and Plug (18" Power Cord and
Non-NEMA plug configuration. Must be
used with FL-1 and TPPH (Thru-Way
Pendant Power Hook). Must specify single
voltage.
PHC-NEMA=Power Cord and NEMA Plug (18"
Power Cord and 20 AMP NEMA
plug configuration). Must be used
with FL-1 and TPPH-NEMA
(Thru-Way Pendant Power Hook).
FH-1=Die-cast Aluminum Fixture Hook (with 3/4"
threads for easy installation)
FL-1=Malleable Iron Plated Fixture Loop (with 3/4"
threads for easy installation)
175, 200, 250, 320, 350 and 400W only.
2
Open Rated socket and lamp must be used.
3
MH available in non-U.S. markets only.
4
Not available in 175, 200, 320 and 350W.
5
Products also available in non-US voltages and 50HZ for international
markets. Consult your Cooper Representative for availabiltiy and ordering
information. 88% Efficient EISA Compliant MP Fixtures not available in 347V
and TT Voltages.
SHK=Die-cast Aluminum Fixture Hook (with
safety screw and 3/4" threads for easy
installation)
F1=Single Fuse (120, 277 or 347V only)
F2=Double Fuse (208, 240 or 480V only)
SCF=3' Aircraft Safety Cable secures Housing to
Ceiling (Alternative lengths available.
Example: SCF6 = 6' Cable)
6
Multi-Tap ballast 120/208/240/277V wired 277V.
7
Triple-Tap ballast 120/277/347V wired 347V.
8
Not applicable for HPS.
9
Requires FH-1or FL-1or SHK.
10
Not available with HL or HC options.
11
Not available with PC3, C3, PHC or MWS. Not available with single circuit
MWS special order.
12
30 second time delay when switching from bright to dim. Consult individual
lamp manufacturers recommendations for compatible lamps. For use with
CWA ballast only.
13
Order separately.
Accessories 13
C3=3' Cord-No Plug - Requires FH-1, FL-1, or SHK9
PC3=3' Cord with NEMA Plug - (120V-L5, 208V-L6-15P,
9
347V-L37-20P and 480V-L8-20P) Other cord lengths are
available by specifying length (PC6 for 6' cord). Requires
FH-1 or FL-1, or SHK. Use with TPPH-NEMA. Specify
Voltage.
PHC=Power Hook Cord and Non-NEMA plug configuration. Must be
used with FL-1 and TPPH (Thru-Way Pendant Power Hook)
PHC-NEMA=Power Cord and NEMA plug - 18" Power Cord and 20
Amp NEMA plug configuration. Must be used with FL-1
and TPPH-NEMA (Thru-Way Pendant Power Hook)
MBT=Twin Mount Bracket (Fixtures must be same voltage and without
hooks, loops or plugs.)
TPPH=Thru-Way Pendant Power Hook. Requires FL-1 and PHC.
Specify Voltage.
TPPH-F=Thru-Way Pendant Power Hook Single Fuse, 120, 277 or 347
Volt. Requires FL-1 and PHC. Specify Voltage.
TPPH-F2=Thru-Way Pendant Power Hook - Double Fused, 208, 240, or
480 Volt. Requires FL-1 and PHC. Specify Voltage.
TPPH-F-QD=Thru-Way Pendant Power Hook Single Fuse, Quick
Disconnect. Requires FL-1 and PHC. Specify Voltage
(120, 277, or 347V)
TPPH-F2-QD=Thru-Way Pendant Power Hook Double Fuse, Quick
Disconnect. Requires FL-1 and PHC. Specify Voltage
(208, 240, or 480V)
TPPH-NEMA=Thru-Way Pendant Power Hook. Requires FL-1 and
PHC-XXXV-NEMA. (Specify Voltage).
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook with Safety Screw
TWMBS=Thru-Way Mounting Box
Q=Quartz Restrike (Hot Strike Only)
EM=Quartz Restrike with ''Delay Relay'' (Quartz
lamp strikes at both hot and cold starts)
EM/SC=Emergency Separate Circuit10
L/TCB=Less Top Connector Box (Housing
shipped less top connector box. (Specify
when using TWMBS accessory)
LL=Lamp Included
W/MWS=MWS Industrial components attached to
the fixture at the factory. (Standard cord
length is 3 ft. 6 ft. and 11 ft. also
available. Please refer to MWS Modular
Wiring System section for additional
information.
HC=LumaWatt Fixture Control Module (Low11, 12
voltage leads pulled out of top
connection box for areas requiring all
wiring to be installed in conduit)
HL=LumaWatt Fixture Control Module (Allows 12
low voltage control wire to be daisy-chained
between fixtures outside AC conduit run
similar to low voltage intercom's, fire alarms
and phone systems)
QLL=Quartz Lamp Included (Lamp is Cooper
designated product based on luminaire
requirements. Lamp is shipped separate
from luminaire unless otherewise noted)
WL=UL Labeled for Wet Location
FILT=Sintered Bronze filter (Sintered bronze filter
prevents the entrance of contaminants)
LAMP TYPE
WATTAGE
Pulse Start Metal Halide (MP)
175, 200, 250, 320, 350, 400W
Metal Halide (MH)
175, 250, 400W
High Pressure Sodium (HP)
150, 250, 400W
VOLTAGE CHART
MT=Multi-Tap
120/208/240/277 (wired 277V)
TT=Triple-Tap
120/277/347 (wired 347V)
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
ADH082539
2015-12-02 11:58:59
Download