Lumark DESCRIPTION The Vertimark features a durable die-cast aluminum top and spun aluminum housing with a computer-designed optical system, making the Vertimark an excellent choice for lighting areas requiring excellent vertical light distribution. U.L. listed and labeled for damp location. CSA Certified. Vertimark is designed to illuminate three-dimensional objects such as machinery dials, spindles, presses, panels and stacked materials. The predominant vertical footcandle distribution and higher beam angles of Vertimark actually distribute light into shadowed areas typically found on machinery and equipment. Catalog # Type Project Comments Date Prepared by S P E C I F I C AT I O N F E AT U R E S ConstructIon REFRACTOR/DOOR: Hinged refractor/door assembly has full perimeter silicone gasketing with easy access thumb screws. Electrical WIRING CHAMBER AND HUB: Easy-access wiring chamber cover with 3/4" IPS threaded hub for quick fixture mounting. BALLAST MOUNTING: Ballast and electrical components are mounted to die- cast aluminum top for cooler operation. High power factor ballast with class H insulation. U.L. Listed for 55° C (131° F) ambient temperature operation. Minimum starting temperature is -40° C (-40° F) for HPS and -30° C (-20° F) for Metal Halide. compartment. OPTICAL SYSTEM: Computer-designed optical system combines a translucent diffuser at the top with a prismatic lens at the bottom for maximum vertical illumination. Finish Optical Polyester powder coat finish for long life and corrosion resistance. REFLECTOR: Spun aluminum reflector has internally hinged door for toolless entry into electrical VF VERTIMARK 150 - 400W High Pressure Sodium Pulse Start Metal Halide Metal Halide ALUMINUM LOW-BAY DIMENSIONS T E C H N I C A L D ATA EISA Compliant G 23 3/4” [603mm] E N E R G Y D ATA CWI Ballast Input Watts 250W HPS HPF (300 Watts) 250W MH HPF (300 Watts) 400W HPS HPF (465 Watts) 400W MH HPF (475 Watts) CWA Ballast Input Watts 175W MP HPF (198 Watts) G 200W MP HPF (227 Watts) G 250W MP HPF (283 Watts) G 320W MP HPF (365 Watts) G 350W MP HPF (400 Watts) G 400W MP HPF (452 Watts) G 400W HPS HPF (465 Watts) S H I P P I N G D ATA Approximate Net Weight: 45 lbs. (20 kgs.) C ER TEM D YS S S 26 1/2” [673mm] TIFIE ADH082539 2015-12-02 11:58:59 VF VERTIMARK P H OTO M E T R I C S 90° 11 26 60° 41 57 30° 72 88 103 CP/100 HPVF-AL-400-MT 400-Watt HPS 50,000-Lumen Clear Lamp Spacing Criterion 1.5 Zone %Lamp Zone 0-30 19.9 0-90 0-40 17.2 90-180 0-60 44.6 Total 90° 15 27 60° 40 52 Coefficients Of Utilization Effective floor cavity reflectance = 20% rc 80% 70% rw 70 50 30 10 70 50 30 RCR 0 104 104 104 104 99 99 99 1 92 86 81 77 88 83 78 2 82 73 66 60 78 70 64 3 74 63 54 47 70 60 52 4 67 54 46 39 63 52 44 5 60 47 38 32 57 45 37 6 55 41 32 26 52 40 31 7 50 36 27 21 47 35 27 8 46 32 24 18 43 31 23 9 42 29 21 16 40 28 20 10 39 26 19 13 37 25 18 30° 65 77 90 CP/100 MPVF-AL-400-MT 400-Watt MP 44,000-Lumen Clear Lamp Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. 50% 50 30 10 30% 50 30 10 10% 50 30 10 99 74 58 46 38 31 25 21 18 15 13 92 76 64 55 48 42 36 32 29 26 23 84 70 59 50 44 38 33 29 26 24 21 78 64 54 46 40 35 30 27 24 22 20 92 72 59 49 41 34 29 25 22 19 17 92 69 54 43 35 29 24 20 17 14 12 84 67 55 45 38 32 27 23 20 18 16 84 64 51 40 33 27 22 18 16 13 11 78 62 50 42 35 30 25 21 19 16 14 78 60 47 38 31 25 21 17 15 12 11 0% 0 75 57 44 35 29 23 19 15 13 10 9 %Lamp 74.7 15.5 90.2 Coefficients Of Utilization Effective floor cavity reflectance = 20% rc 80% 70% rw 70 50 30 10 70 50 30 RCR 0 102 102 102 102 98 98 98 1 90 85 80 76 86 82 77 2 81 73 66 60 77 70 63 3 73 62 54 48 69 60 52 4 66 54 46 39 63 52 44 5 60 47 39 32 57 45 37 6 54 41 33 26 51 40 31 7 49 36 27 21 47 34 27 8 45 32 24 18 43 31 23 9 24 29 21 16 40 28 20 10 39 26 18 13 37 25 18 Spacing Criterion 1.5 Zone %Lamp Zone 0-30 10.1 0-90 0-40 17.5 90-180 0-60 47.6 Total 10 Candlepower Degree CP 0 4380 5 4307 15 4071 25 4531 35 4187 45 5160 55 7704 65 4009 75 2667 85 2258 90 2069 10 50% 50 30 10 30% 50 30 10 10% 50 30 10 98 74 58 46 38 31 26 21 18 15 13 90 75 64 55 48 42 36 32 28 25 23 83 69 59 50 44 38 33 29 26 23 21 77 63 54 46 40 35 31 27 24 21 20 90 72 59 49 41 35 29 25 22 19 17 90 68 54 44 36 30 24 20 17 14 12 83 66 55 45 38 32 27 23 20 18 16 83 64 51 41 34 28 23 18 16 13 12 77 61 51 42 36 30 25 21 19 16 14 77 59 47 38 32 26 21 17 15 12 11 0% 0 74 56 45 36 29 24 19 15 13 11 9 Candlepower Degree CP 0 7402 5 7137 15 6716 25 7635 35 7020 45 9242 10692 55 65 9080 75 4680 85 3853 90 3533 %Lamp 73.8 14.9 88.7 ADH082539 2015-12-02 11:58:59 VF VERTIMARK ORDERING INFORMATION Sample Number: MPVF-AL-250-MT-OR-Q Lamp Type MP=Pulse Start Metal 1, 2 Halide Lamp Wattage Voltage MP MH=Metal Halide2, 3 HP=High Pressure 4 Sodium 175=175W 200=200W 208V Series VF=Vertimark Lens Type AL=Prismatic Acrylic Lens PC3=3' Cord with NEMA Plug (120V-L5-15P, 208V-L6-15P, 347V-L37-20P, AND 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6' Cord) Requires FH-1 or FL-1, or SHK. Example: PC3-120V Use with TPPH-NEMA. Specify Voltage. 240V 277V 250=250W 320=320W 347V 480V 350=350W 400=400W MH Options C3=3' Cord with no plug (Specify Voltage)9 5 120V MT TT 3 175=175W 250=250W 6 7 Socket OR=Open Rated Socket 8 for Metal Halide Lamps 400=400W HP __=Non Applicable (HPS or Not compatible with OR Socket) 150=150W 250=250W 400=400W Notes: 1 9 PHC=Power Cord and Plug (18" Power Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage. PHC-NEMA=Power Cord and NEMA Plug (18" Power Cord and 20 AMP NEMA plug configuration). Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook). FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation) FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation) 175, 200, 250, 320, 350 and 400W only. 2 Open Rated socket and lamp must be used. 3 MH available in non-U.S. markets only. 4 Not available in 175, 200, 320 and 350W. 5 Products also available in non-US voltages and 50HZ for international markets. Consult your Cooper Representative for availabiltiy and ordering information. 88% Efficient EISA Compliant MP Fixtures not available in 347V and TT Voltages. SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation) F1=Single Fuse (120, 277 or 347V only) F2=Double Fuse (208, 240 or 480V only) SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available. Example: SCF6 = 6' Cable) 6 Multi-Tap ballast 120/208/240/277V wired 277V. 7 Triple-Tap ballast 120/277/347V wired 347V. 8 Not applicable for HPS. 9 Requires FH-1or FL-1or SHK. 10 Not available with HL or HC options. 11 Not available with PC3, C3, PHC or MWS. Not available with single circuit MWS special order. 12 30 second time delay when switching from bright to dim. Consult individual lamp manufacturers recommendations for compatible lamps. For use with CWA ballast only. 13 Order separately. Accessories 13 C3=3' Cord-No Plug - Requires FH-1, FL-1, or SHK9 PC3=3' Cord with NEMA Plug - (120V-L5, 208V-L6-15P, 9 347V-L37-20P and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6' cord). Requires FH-1 or FL-1, or SHK. Use with TPPH-NEMA. Specify Voltage. PHC=Power Hook Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook) PHC-NEMA=Power Cord and NEMA plug - 18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook) MBT=Twin Mount Bracket (Fixtures must be same voltage and without hooks, loops or plugs.) TPPH=Thru-Way Pendant Power Hook. Requires FL-1 and PHC. Specify Voltage. TPPH-F=Thru-Way Pendant Power Hook Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC. Specify Voltage. TPPH-F2=Thru-Way Pendant Power Hook - Double Fused, 208, 240, or 480 Volt. Requires FL-1 and PHC. Specify Voltage. TPPH-F-QD=Thru-Way Pendant Power Hook Single Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (120, 277, or 347V) TPPH-F2-QD=Thru-Way Pendant Power Hook Double Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (208, 240, or 480V) TPPH-NEMA=Thru-Way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. (Specify Voltage). FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook with Safety Screw TWMBS=Thru-Way Mounting Box Q=Quartz Restrike (Hot Strike Only) EM=Quartz Restrike with ''Delay Relay'' (Quartz lamp strikes at both hot and cold starts) EM/SC=Emergency Separate Circuit10 L/TCB=Less Top Connector Box (Housing shipped less top connector box. (Specify when using TWMBS accessory) LL=Lamp Included W/MWS=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft. 6 ft. and 11 ft. also available. Please refer to MWS Modular Wiring System section for additional information. HC=LumaWatt Fixture Control Module (Low11, 12 voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) HL=LumaWatt Fixture Control Module (Allows 12 low voltage control wire to be daisy-chained between fixtures outside AC conduit run similar to low voltage intercom's, fire alarms and phone systems) QLL=Quartz Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped separate from luminaire unless otherewise noted) WL=UL Labeled for Wet Location FILT=Sintered Bronze filter (Sintered bronze filter prevents the entrance of contaminants) LAMP TYPE WATTAGE Pulse Start Metal Halide (MP) 175, 200, 250, 320, 350, 400W Metal Halide (MH) 175, 250, 400W High Pressure Sodium (HP) 150, 250, 400W VOLTAGE CHART MT=Multi-Tap 120/208/240/277 (wired 277V) TT=Triple-Tap 120/277/347 (wired 347V) Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. ADH082539 2015-12-02 11:58:59