Spec Sheet - Villa Lighting

advertisement
FAIL-SAFE
D ES C R IPTION
The Fail-Safe Changing Views is a new series of visual therapy luminaires
by Cooper Lighting. Designed to bring warmth, ambience, and positive
energy into a variety of environments, these luminaires help create a
calming influence throughout any facility. Choose from a variety of images
in the standard picture gallery to create single or multiple murals. The
Changing Views VRGC Series features a nominal 4-1/2" deep para-contoured
fixture housing, high reflectivity and optimum lamp to lens spacing.
The series produces total uniformity of light in the luminous area and is
compatible with all of today's popular ceiling systems and is available with a
number of options and accessories for application versatility.
®
Type
Catalog #
Project
Date
Comments
Prepared by
SPE C IFIC A TION FEA T U R E S
suspension points provided. KOs
for continuous row wiring.
C on s t r u c t i o n
Nominal 4-1/2" deep, paracontoured housing, die-formed
code gauge, prime cold rolled
steel. Die embossed housing has
full length die formed stiffeners for
added strength. Deep "V" ballast/
wireway cover easily removed
without tools. Die-formed captive
lampholder bracket fully encloses
lampholder wiring permitting
easy lampholder replacement.
Heavy endplates are securely
attached with interlocking tabs and
screws. Four auxiliary fixture end
Frame/S hield ing
Multistage, iron phosphate
pretreatment ensures maximum
bonding and rust inhibitor. Lighting
grade, baked white enamel finish.
Die formed, heavy gauge, flat
steel door with reinforced mitered
corners and baked white enamel
finish. Positive light seals. Frame
and lens are secured to housing
with 4 or 6 stainless steel T20
TORX®-head screws.
Hi ngi ng/L a tc hing
Electrical *
Positive cam action spring loaded
steel latches with baked white
enamel finish. Safety-lock T-hinges
allow hinging and latching either
side.
Ballasts are CBM/ETL Class "P" and
are positively secured by mounting
bolts. Pressure lock lampholders.
UL/CUL listed.
F i ni s h
Changing Views - Visual Therapy
CV-2VRGC
4-5/8"
[117mm]
2x2
2x4
T8
Fluorescent
Healthcare: Changing Views
Visual Therapy
23-3/4" [603mm]
MOUNTING D A TA
2' x 2'
2' x 4'
7/8" [22mm] Access Plate
7/8" [22mm] K.O. (2)
K.O. (2)
Access Plate
7/8" [22mm] K.O. (2)
7/8" [22mm]
K.O. (2)
1-1/2"
[38mm]
1-1/2"
[38mm]
23-3/4"
[603mm]
23-3/4"
[603mm]
3-3/4" [95mm]
5-1/4" [133mm]
6-1/4" [159mm]
3-3/4" [95mm]
5-1/4" [133mm]
7-23/32" [196mm]
48" [1219mm]
24" [610mm]
Indicates a 3 Lamp Channel Diagram
ENERGY DATA
Input Watts
L AM P C ONFIGUR A TI O N S
EB Ballast & STD Lamps*
317 (52)
332 (91)
3 LAMP
4-5/8" [117mm]
7"
7"
[178mm] [178mm]
23-3/4" [603mm]
*Reference the lamp/ballast
data in the
Technical Section for specific
lamp/ballast
requirements
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADF081403
2012-08-01 15:40:26
C V -2 V R GC
S A MPL E IM A GES (FOR C O M P L E T E I M AG E S E L E C T I O N VI S I T WWW.COOP E RL IGH T ING.COM)
SFL38
SEL2525
ASP7389
SCPR9034
ORDER ING INFOR M A TION
S A M P L E N U M B E R : C V- 2 V R G C - 3 3 2 - S C P R 6 1 3 - U N V- E B 8 1 - 4 C
Product
Fa m i l y
Width
S e ri e s
Tri m
Ty p e
S e ri e s
CV
2
VR
G
C
CV=Changing
Views
Door
Ty p e
No. of
Lamps
Wa t t a g e
(Length)
2x2
17= 17W T8
14= 14W T5
24= 24W T5
2=2
2x4
32= 32W T8
28= 28W T5
54= 54W T5
VR=Vandal Resistant
G=Grid/Lay-in – 9/16”, 1” Grid 1
C=Ceiling
Image Reference 2
Standard=Flat White Steel Door
(Leave Blank)
Lens
Vo l t a g e
Ballast 3
Ty p e
120=120V
277=277V
347=347V
UNV=Universal
Voltage 120-277V
EB81= (1) ballast for use with
T8 lamps
EB82= (2) ballasts for use with
T8 lamps
EB51= (1) ballast for use with
T5 lamps
EB52= (2) ballasts for use with
T5 lamps
1 Doors will be shipped separately for easy installation.
2 For image selection, part numbers and layout options, visit www.ccoperlighting.com
For custom images, contact Cooper Lighting representative.
Accessories
Configuration
Notes:
2=Two Lamps
3=Three Lamps
4=Four Lamps
Configuration
2x2 Fixtures
2A – One Square
2B – Two Rectangle
2C – Four Square
2D – Six Rectangle
2E – Nine Square
2F – Twelve Rectangle
2x4 Fixtures
4A – One Rectangle
4B – Two Square
4C – Three Rectangle
4D – Four Rectangle
4E – Five Rectangle
4F – Six Rectangle
EQ -CLIP-U=T-Bar Safety
Eathquake Clips 4
3 For specific electronic ballast, specify brand and catalog number.
4 EQ Grid Clip is recommended for all 9/16" ceiling systems
C ONF IGUR A TION EX A M PL E S
2A
2D
2C
2E
2F
2B
4C
4F
4A
4B
4D
4E
• Select a configuration and
corresponding luminaire layout.
• Select desired imagery from the
gallery (for the most up to date
information visit our web site at
www.cooperhealthcaresolutions.com)
• Indicate all the above information
when placing an order.
Important Note:
Configuration will determine the number of fixtures. Use only one catalog number per configuration.
Specifications and dimensions subject to change without notice.
Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADF081403
2012-08-01 15:40:26
Download