FAIL-SAFE D ES C R IPTION The Fail-Safe Changing Views is a new series of visual therapy luminaires by Cooper Lighting. Designed to bring warmth, ambience, and positive energy into a variety of environments, these luminaires help create a calming influence throughout any facility. Choose from a variety of images in the standard picture gallery to create single or multiple murals. The Changing Views VRGC Series features a nominal 4-1/2" deep para-contoured fixture housing, high reflectivity and optimum lamp to lens spacing. The series produces total uniformity of light in the luminous area and is compatible with all of today's popular ceiling systems and is available with a number of options and accessories for application versatility. ® Type Catalog # Project Date Comments Prepared by SPE C IFIC A TION FEA T U R E S suspension points provided. KOs for continuous row wiring. C on s t r u c t i o n Nominal 4-1/2" deep, paracontoured housing, die-formed code gauge, prime cold rolled steel. Die embossed housing has full length die formed stiffeners for added strength. Deep "V" ballast/ wireway cover easily removed without tools. Die-formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end Frame/S hield ing Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibitor. Lighting grade, baked white enamel finish. Die formed, heavy gauge, flat steel door with reinforced mitered corners and baked white enamel finish. Positive light seals. Frame and lens are secured to housing with 4 or 6 stainless steel T20 TORX®-head screws. Hi ngi ng/L a tc hing Electrical * Positive cam action spring loaded steel latches with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. Ballasts are CBM/ETL Class "P" and are positively secured by mounting bolts. Pressure lock lampholders. UL/CUL listed. F i ni s h Changing Views - Visual Therapy CV-2VRGC 4-5/8" [117mm] 2x2 2x4 T8 Fluorescent Healthcare: Changing Views Visual Therapy 23-3/4" [603mm] MOUNTING D A TA 2' x 2' 2' x 4' 7/8" [22mm] Access Plate 7/8" [22mm] K.O. (2) K.O. (2) Access Plate 7/8" [22mm] K.O. (2) 7/8" [22mm] K.O. (2) 1-1/2" [38mm] 1-1/2" [38mm] 23-3/4" [603mm] 23-3/4" [603mm] 3-3/4" [95mm] 5-1/4" [133mm] 6-1/4" [159mm] 3-3/4" [95mm] 5-1/4" [133mm] 7-23/32" [196mm] 48" [1219mm] 24" [610mm] Indicates a 3 Lamp Channel Diagram ENERGY DATA Input Watts L AM P C ONFIGUR A TI O N S EB Ballast & STD Lamps* 317 (52) 332 (91) 3 LAMP 4-5/8" [117mm] 7" 7" [178mm] [178mm] 23-3/4" [603mm] *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements Specifications and dimensions subject to change without notice. Consult your representative for additional options and finishes. ADF081403 2012-08-01 15:40:26 C V -2 V R GC S A MPL E IM A GES (FOR C O M P L E T E I M AG E S E L E C T I O N VI S I T WWW.COOP E RL IGH T ING.COM) SFL38 SEL2525 ASP7389 SCPR9034 ORDER ING INFOR M A TION S A M P L E N U M B E R : C V- 2 V R G C - 3 3 2 - S C P R 6 1 3 - U N V- E B 8 1 - 4 C Product Fa m i l y Width S e ri e s Tri m Ty p e S e ri e s CV 2 VR G C CV=Changing Views Door Ty p e No. of Lamps Wa t t a g e (Length) 2x2 17= 17W T8 14= 14W T5 24= 24W T5 2=2 2x4 32= 32W T8 28= 28W T5 54= 54W T5 VR=Vandal Resistant G=Grid/Lay-in – 9/16”, 1” Grid 1 C=Ceiling Image Reference 2 Standard=Flat White Steel Door (Leave Blank) Lens Vo l t a g e Ballast 3 Ty p e 120=120V 277=277V 347=347V UNV=Universal Voltage 120-277V EB81= (1) ballast for use with T8 lamps EB82= (2) ballasts for use with T8 lamps EB51= (1) ballast for use with T5 lamps EB52= (2) ballasts for use with T5 lamps 1 Doors will be shipped separately for easy installation. 2 For image selection, part numbers and layout options, visit www.ccoperlighting.com For custom images, contact Cooper Lighting representative. Accessories Configuration Notes: 2=Two Lamps 3=Three Lamps 4=Four Lamps Configuration 2x2 Fixtures 2A – One Square 2B – Two Rectangle 2C – Four Square 2D – Six Rectangle 2E – Nine Square 2F – Twelve Rectangle 2x4 Fixtures 4A – One Rectangle 4B – Two Square 4C – Three Rectangle 4D – Four Rectangle 4E – Five Rectangle 4F – Six Rectangle EQ -CLIP-U=T-Bar Safety Eathquake Clips 4 3 For specific electronic ballast, specify brand and catalog number. 4 EQ Grid Clip is recommended for all 9/16" ceiling systems C ONF IGUR A TION EX A M PL E S 2A 2D 2C 2E 2F 2B 4C 4F 4A 4B 4D 4E • Select a configuration and corresponding luminaire layout. • Select desired imagery from the gallery (for the most up to date information visit our web site at www.cooperhealthcaresolutions.com) • Indicate all the above information when placing an order. Important Note: Configuration will determine the number of fixtures. Use only one catalog number per configuration. Specifications and dimensions subject to change without notice. Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801 ADF081403 2012-08-01 15:40:26