Metalux

advertisement
Metalux
D ES C R IPTION
ArcLine is a premium grade specification lensed troffer series. This
innovative, high quality luminaire is dedicated to the latest lamp and
micro electronic ballast technology for optimal performance and energy
efficiency. The ArcLine is compatible with all of today’s popular ceiling
systems and is available with a number of options and accessories for
application versatility.
The ArcLine series features efficiency, quality and performance. The
series is an excellent choice for commercial office spaces, schools,
hospitals or retail merchandising areas.
Type
Catalog #
Project
Date
Comments
Prepared by
SPE C IFIC A TION FEA T U R E S
C on s t r u c t i o n
E le ctrica l
H inging/Latching
Rigid housing is die formed of
code gauge prime cold rolled steel
and features full length die-formed
stiffeners and unibody endplate
for added strength. Side flanges
are hemmed. Innovative design
provides superior lens brightness
uniformity and visual comfort.
Die formed captive lampholder
brackets fully enclose lampholder
wiring permitting easy lampholder
replacement. Unibody endplates
are securely attached with
interlocking tabs and screws. Four
auxiliary fixture end suspension
points provided. Ample KOs are
provided for continuous row
wiring. Endplates have integral
Grid-lock feature for safety and
convenience.
Ballasts are CBM/ETL Class
“P” and are positively secured
by mounting bolts. Rotor-lock
lampholders ensure positive lamp
retention. UL/CUL listed. Suitable
for damp locations.
Positive cam action steel latches
with baked white enamel finish.
Safety-lock T-hinges allow hinging
and latching either side. Door
assembly hinges down for easy
access from below without tools.
F in ish
Frame/Shielding
Multistage, iron phosphate
pretreatment ensures maximum
bonding and rust inhibition.
Housing and ballast cover finished
with new 90% reflective white
enamel for superior performance.
Die formed, heavy gauge, flat
steel door with reinforced mitered
corners and paint after fabrication,
baked matte white enamel finish.
Positive light seals. Light stabilized,
acrylic frosted lens.
2ALN
314T5
2' X 2' TROFFER
3 T5 LAMPS
Specification Architectural
Troffer
For Use In Insulated
Ceilings
3-1/4"
[83mm]
23-3/4" [603mm]
MO UNTING D A TA
D OOR F RA ME S
ALN
Flat, White Steel
ENERGY DATA
Input Watts:
EB Ballast & STD Lamps
314T5 (49)
23-3/4"
[603mm]
L A MP CONF IGURA T IONS
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
**Consult Pre Sales Technical Support.
****When ordering Flange Kit for
installation in drywall ceilings, see
options and accessories compatibility
section and ordering logic.
3-1/4" [83mm]
23-3/4" [603mm]
23-3/4" [603mm]
CEI LING C OM PA TIB I L I T Y
G
Grid/Lay-in
Standard
G
Concealed T
G
Slot Grid
Ceiling
Type
Trim
Type
Exposed Grid
Concealed T
Slot Grid
G
G
G
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
TO LOCAL, STATE OR FEDERAL LAWS
(Verify compatibility/ consult
factory.)
Safe and convenient means of
disconnecting power.
ADF122035
2015-06-09 11:41:18
2 ALN T 5
PHOTOM ETR IC S
90˚
75˚
350
60˚
700
45˚
1050
0˚
15˚
30˚
2ALNG-314T5-UNVEBT1-U
Electronic Ballast
(3) F14T5 Lamps
1300 Lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.3 x
mounting height
Efficiency 74.3%
Lumens: 2899
LER = FL61
Yearly Cost of 1000
lumens, 3000 hrs at
.08 KWH = $3.93
Test Report:
2ALNG-314T5-UNVEBT1-U.IES
Candlepower
Along II
1028
1020
1005
974
933
882
824
758
686
608
531
452
374
297
223
154
91
38
0
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
45°
1028
1024
1009
984
948
905
856
800
735
669
595
517
438
358
279
202
130
51
0
Across ⊥
1028
1026
1014
993
965
930
890
843
789
728
660
584
504
422
337
255
159
55
0
C o e f fi c i e n t s o f U t i l i z a t i o n
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
88
81
73
67
61
56
52
48
45
42
39
88
77
67
59
52
47
42
38
35
32
29
88
74
62
53
46
40
35
31
28
26
23
88
71
58
48
40
35
30
27
24
22
20
86
79
71
65
59
55
50
47
44
41
38
86
75
66
58
51
46
41
37
34
31
29
86
72
61
52
45
39
35
31
28
25
23
86
70
57
47
40
35
30
27
24
21
19
20%
50%
50 30 10
30%
50 30 10
50
83
72
63
55
49
44
40
36
33
31
28
79
69
61
53
47
43
39
35
32
30
28
76
67
58
51
46
41
37
34
31
29
27
83
70
59
51
44
39
34
31
28
25
23
83
68
56
47
40
34
30
27
24
21
19
79
67
57
49
43
38
34
30
27
25
23
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
792
1292
2270
2899
2899
%Lamp
20.3
33.1
58.2
74.3
74.3
%Fixture
27.3
44.6
78.3
100.0
100.0
Average
0-Deg
cd/sm
3294
3044
2752
2389
1854
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
79
65
54
46
39
34
30
26
24
21
19
10%
30 10
Average
45-Deg
cd/sm
3592
3443
3276
3068
2499
76
65
56
48
42
37
33
30
27
24
22
76
64
53
45
39
33
29
26
23
21
19
0%
0
74
62
51
43
37
32
28
25
22
20
18
Average
90-Deg
cd/sm
3901
3853
3758
3774
2701
Specifications and
dimensions subject to
change without notice.
ADF122035
2015-06-09 11:41:18
2 ALN T 5
ORDER ING INFOR M A TION
SAMPLE NUMBER: 2ALNG-314T5-UNV-EBT1-U
Rating
Blank=
Standard
ATW-SW4=
Chicago
Rated
Width
2=2' Width
Series
ALN=ArcLine Series
Number of
Lamps
3=3 Lamps
Voltage (2)
347V=347 Volt
UNV=Universal
Voltage 120-277 (3)
(Not included)
Wattage (Length)
14T5=14W T5 (24")
Shielding
Blank=Smooth Frosted
Acrylic (standard)
Trim Type
G=Grid/Lay-in (Standard) (1)
G=Concealed T
G=Slot Grid
Options
GL=Single Element Fuse
GM=Double Element Fuse
Lamps=Lamps Installed
(see options and
accessories)
Flex=Flex Installed
(Reference Flex ordering
information)
EL=Emergency Installed (6)
Ballast Type (2)
EBT =T5/T5HO Electronic
Program Rapid Start.
Total Harmonic Distortion
< 10%. Standard Ballast
Factor=1.0
Number of Ballasts
1=1 Ballast
Options
G1=Gasket, Door Frame
and Housing (Standard)
G2=G1 plus Gasket
between Lens and Door
G3=G1 and G2 plus
Gasketing on Mounting
Surface of Fixture Trims
Packaging
U=Unit Pack
PALC=Job Pack,
in carton
ACCESSORIES
EQ-CLIP-U=T-BAR Safety Earthquake Clips (1)
DF-22-W=2' x 2' Drywall Flange Kit
Door Frame
Standard=Flat White Steel Door
(Leave Blank)
(1)
NOTES: An EQ Grid Clip is recommended for all 9/16" ceiling systems.
Not available when specifying emergencies, voltage must be specific.
(3)
(2)
Products also available in non-US voltages and frequencies for international markets.
Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information.
SH IP P ING D ATA
Catalog No.
2ALNG-314T5
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
Specifications and
dimensions subject to
change without notice.
Wt.
10 lbs.
ADF122035
2015-06-09 11:41:18
Download