FAIL-SAFE D ES C R IPTION Type Catalog # The VRGC features a nominal 4-1/2" deep para-contoured fixture housing, high reflectivity and optimum lamp to lens spacing. It produces total uniformity of light in the luminous area and is compatible with all of today's popular ceiling systems and is available with a number of options and accessories for application versatility. Designed to offer maximum efficiency and performance for today's unique interior specifications, the VRGC is perfect for use in office spaces, schools, hospitals, industrial facilities and commercial areas with high traffic volume. ® Project Date Comments Prepared by S PEC IFIC A TION FEA T U R E S Construction F i ni s h Frame/S hield ing Nominal 4-1/2” deep, paracontoured housing, die-formed code gauge, prime cold rolled steel. Die-embossed housing has full-length, die-formed stiffeners for added strength. Deep “V” ballast/ wireway cover easily removed without tools. Die formed captive lampholder bracket fully encloses lampholder wiring permitting easy lampholder replacement. Heavy endplates are securely attached with interlocking tabs and screws. Four auxiliary fixture end suspension points provided. KOs for continuous row wiring. Endplates have integral Grid-Lock feature for safety and convenience. Multistage, iron phosphate pretreatment ensures maximum bonding and rust inhibitor. Lighting grade, baked white enamel finish. Die-formed, heavy gauge, flat steel door with reinforced mitered corners and baked white enamel finish. Positive light seals. Frame and lens are secured to housing with 4 or 6 T20 stainless steel TORX® screws. Hi ngi ng/L a tc hi n g Positive cam action spring-loaded steel latches with baked white enamel finish. Safety-lock T-hinges allow hinging and latching either side. Electrical * Ballasts are CBM/ETL Class “P” and are positively secured by mounting bolts. Pressure lock lampholders. 2VR 2x4 Fluorescent Vandal Resistant Labels UL/cUL listed for damp locations. RECESSED Lens Troffer 4-5/8" [117mm] 23-3/4" [603mm] MOUNTING D A TA 7/8" [22mm] K.O. (2) Access Plate 7/8" [22mm] K.O. (2) Access Plate 7/8" [22mm] K.O. (2) 7/8" [22mm] K.O. (4) 1-1/2" [38mm] 1-1/2" [38mm] 23-3/4" [603mm] 23-3/4" [603mm] 5-1/4" [133mm] 3-3/4" [95mm] 7-23/32" [196mm] 5-1/4" [133mm] 3-3/4" [95mm] 48" [1219mm] 7-23/32" [196mm] 48" [1219mm] L AM P C ONFIGUR A TI O N S D OOR F RA ME 10-3/4" [273mm] 23-3/4" [603mm] VRGC Flat, White Steel 4-5/8" [117mm] 4-5/8" [117mm] 4-5/8" [117mm] 7" 7" [178mm] [178mm] 23-3/4" [603mm] X=5-3/4" [146mm] 4-3/4" 4-3/4" X [121mm] [121mm] 23-3/4" [603mm] Grid/Lay-in Standard G Concealed T G Slot Grid F Flange Trim With Supporting Swing Gates Ceiling Type** Trim Type Exposed Grid Concealed T Slot Grid Flange G G G F C ER TEM S YS D G S C EILING C OM PA TIB IL I T Y TIFIE ADC041483 2014-10-07 11:21:29 2 V R - 2 X4 ORDER ING INFOR M A TION SAMPLE NUMBER: 2VRGC-232A Product Family Width 2 Door Series Type Trim Type VR No. of Lamps Wattage (Length) Lens Type Voltage Options (Add as Suffix) Ballast Type C 2, 3, 4 or 6 Lamps (Not included) 2=2' VR EB _ _ = Generic Electronic Ballast No. of Ballasts 1 or 2 1 Lamp Size 8 = T8 28T5=28W T5 (48") 32=32W T8 (48") 54T5=54W T5HO (48") G = Grid/Lay-in - Standard G= Concealed T G =Slot Grid F = Flange Trim (For specific Electronic Ballast specify Brand and Catalog Number.) ACTF140= .140 Thick ACTF187= .187Thick PA375 = .250 polycarbonate with .125 prismatic overlay (standard with 6S option) C Standard = Flat White Steel Door (Leave Blank) PAF= Painted after Fabrication GL= Internal Single Element Fusing GM= Dual Element Fusing EL4= Emergency Lighting, self contained EQ= T-BAR Safety Earthquake Clips 2 RLS= Rotor-Lock Socket (T8 Lamps only) 6S= Six T20 TORX®-head Screws (3 per side) SC =Safety Chain For additional options, please consult Cooper Lighting Representative. Notes: 1 Two ballast in 2 or 4 lamp require LAO (less access opening). 120=120V 277=277V 347=347V UNV=Universal Voltage (120-277V) 2 EQ Grid Clip is recommended for all 9/16” ceiling systems. PH OTOM ETR IC S C o e f fi c i e n t s o f U t i l i z a t i o n || 2VRGC-232A Electronic Ballast F32T8/35K Lamps 2800 Lumens Spacing criterion: (II) 1.3 x mounting height, ( ) 1.4 x mounting height Efficiency 79.4% Test Report #108P156 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Candela Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 95 87 81 74 68 63 58 53 49 45 42 95 84 75 67 60 53 48 43 39 35 31 95 81 70 61 53 47 41 36 32 28 25 95 78 66 56 49 42 36 32 27 24 21 92 85 79 72 67 61 56 52 48 44 41 92 82 73 66 59 52 47 42 38 34 31 92 80 69 60 53 46 41 36 32 28 25 92 77 65 56 48 41 36 32 27 24 21 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 0% 0 88 79 71 63 57 51 46 41 37 33 30 84 76 68 61 55 49 44 40 36 32 29 81 73 66 59 53 48 43 39 35 32 29 79 69 59 52 45 38 34 29 25 22 19 88 77 67 59 52 45 40 35 31 27 25 88 75 64 55 48 41 36 31 27 23 21 84 74 65 57 51 44 39 35 31 27 24 84 72 62 54 47 41 35 31 27 23 21 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 o 30 x 60 60 x 30 60 x 60 Lumens %Lamp %Fixture 1328 2203 3742 4447 4447 23.7 39.3 66.8 79.4 79.4 29.9 49.5 84.1 100.0 100.0 Height Along 8.5' 10.0' 72 75 68 70 62 64 70 73 62 64 81 72 63 56 50 43 39 34 30 27 24 81 70 61 53 46 40 35 31 27 23 21 Height Across 8.5' 10.0' 69 73 65 68 57 60 69 71 58 61 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 45 o Across 1656 1647 1627 1595 1545 1481 1400 1299 1171 1013 835 667 520 393 281 191 126 66 0 1656 1655 1644 1623 1590 1546 1486 1405 1294 1138 954 764 579 412 269 173 126 77 0 1656 1663 1660 1649 1633 1604 1557 1493 1395 1245 1031 799 597 428 298 221 165 94 0 LER = FL-66 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.64 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton’s Cooper Lighting Business 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.cooperlighting.com Specifications and dimensions subject to change without notice. ADC041483 2014-10-07 11:21:29